DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

Size: px
Start display at page:

Download "DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit"

Transcription

1 Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection: G ½ G 3, ½ 3 NPT IG Material: brass or st. st Analogue, frequency and switching s, compact electronic with digital display, dosing and counter electronic KOBOLD companies worldwide: ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, MOROCCO, NETHERLANDS, PERU, PHILIPPINNES, POLAND, ROMANIA, SINGAPORE, SLOVAKIA, SOUTH KOREA, SPAIN, SWITZER- LAND, TAIWAN, THAILAND, TUNISIA, USA, VENEZUELA, VIETNAM KOBOLD Messring GmbH Nordring -4 D-679 Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com

2 Description The new KOBOLD type DUK fl ow meters are used for the measurement, monitoring, metering and dosing of low viscosity fl uids. The devices work on the principle of the difference in running times. This is based on the fact that ultrasonic waves in a medium are infl uenced by the speed of fl ow. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of ultrasound signals. If there is no fl ow, then the running times of both signals are identical. If the medium is fl owing, then the running time of the signal against the fl ow is longer than that with the fl ow. The running time difference, which is determined by a microprocessor, is proportional to the speed of fl ow. T V m C L Electronic The devices can be equipped with a switching, a frequency or an analogue. In addition, a compact circuit can be selected that features a digital display, a switching and an analogue. The device series is rounded off by an optionally available dosing and meter circuit. The meter circuit indicates the momentary fl ow rate in the fi rst line of the display and the partial or total quantity in the second line. A dosing circuit controls simple fi lling tasks and similarly measures fl ow rates, total amounts and fi lling amounts. The analogue and two relay s can be used for further processing of the signals. T Advantages High range span of :0 Small pressure loss High repeat accuracy ± 0.% of F.S. Independent from density and temperature Areas of Application Machine building Automotive Robotic Cooling Hot water Technical Data Sensor Measuring principle: Range: Medium: Viscosity: Accuracy: Repeat accuracy: Mounting position: ultrasonic see table liquids with max. % solid max. 3 mm²/s ±. % of F.S. ±0. % of F.S. In-/Outlet: Media temperature: C Ambient temperature: C Response time: in all directions, fl ow in direction of the arrow (horizontal: electronic on top or below) 0 x DN approx s (depending on electronic version) Pressure: 0 6 bar Pressure loss: max. 0 mbar at F.S. Protection: IP 6 Wetted Parts Sensor housing: brass or st. st Sensors: PEEK Seal: NBR, other on request Measuring Ranges and Weights Model Measuring range [L / min] Size [G / NPT] DUK-...S30x DUK- F3xo DUK-...Lxx3 DUK-...C3xx DUK-...Exxx DUK-...Gxxx DUK with ADI 4 V DUK with ADI 30 / / 48 V DUK-xx ½" approx. 80 g approx. 00 g approx. 000 g approx. 0 g approx. 700 g DUK-xx ¾" approx. 00 g approx. 0 g approx. 00 g approx. 30 g approx. 900 g DUK-xx " approx. 40 g approx. 60 g approx. 600 g approx. 70 g approx g DUK-xx ½" approx. 30 g approx. 0 g approx. 00 g approx. 360 g approx. 400 g DUK-xx9-0 " approx g approx g approx. 390 g approx. 00 g approx. 60 g DUK-xxB " approx. 700 g approx g approx. 70 g approx g approx. 890 g No responsibility taken for errors;

3 DUK-...S300, DUK-...S30D Duo-LED for switch status Switching (..S300): relay SPDT, max. A / 30 V DC Switching (..S30D): active 4 V DC, N/C and N/O Switch point: % of f.s. in 0 %- steps that can be confi gured by the customer using a rotary switch Power supply: 4 V DC ± 0 % Power consumption: 30 ma Electrical connection: plug M, -pin DUK-...F300, DUK- F390 Impulse : PNP, Open Collector, max. 00 ma Frequency at F.S.: 00 Hz ( F300) Hz ( F390) proportional to fl owrate Power supply: 4 V DC ± 0 % Power consumption: ma Electrical connection: plug M, -pin DUK-...L303; DUK-...L343 Output: 0(4)-0 ma, 3-wire Power supply: 4 V DC ± 0 % Power consumption: max. 4 ma Electrical connection: plug M x DUK-...L443 (usage with AUF-3000) Output: 4-0 ma, 3-wire Power supply: 4 V DC ± 0 % Power consumption: max. 4 ma Electrical connection: plug DIN 4360 DUK-...C3xx (Compact electronic) 3-digit LED Analogue : 0(4)...0 ma adjustable (only DUK-...C34x) Switching : () semiconductor PNP or NPN, set at factory Contact function: N/C-N/O-frequency programmable (approx. 400 Hz at F.S., uncalibrated) via buttons Power supply: 4 V DC ± 0 % Power consumption: approx. 00 ma Electrical connection: plug M x DUK-...Exxx (Counter electronic) LCD, x 8 digit, illuminated total, part and fl ow quantities, units selectable Analogue 0(4)...0 ma adjustable Switching : relays, max. 0 V/ A /000 VA via 4 buttons Functions: reset, MIN/MAX memory, fl ow monitor, monitoring for part and total quantity, language Power supply: 4 V DC ± 0 %, 3-wire Power consumption: approx. 70 ma Electrical connection: cable connection or M plug more technical details see data sheet ZED in the brochure Z DUK-...Gxxx (Dosing electronic) LCD, x 8 digit, illuminated dosing-, total-, and fl ow quantity, units selectable Analogue 0(4)...0 ma adjustable Switching : relays, max. 0 V / A / 000 VA via 4 buttons Functions: dosing (relay S), start, stop, reset, fi ne dosing,correction amount, fl ow switch, total quantity, language Power supply: 4 V DC ± 0 %, 3-wire Power consumption: approx. 70 ma Electrical connection: cable connection or M plug more technical details see data sheet ZED in the brochure Z DUK with ADI electronic bar graph, 3.-digit digital or combination display; batch system Analogue : 0(4)... 0 ma, 0 0 V Switching : x relays / SPDT max. / 30 V AC, A resistive load max. 30 V DC / A or Open-Collector - 0 V DC, I total. = 0 ma via 3 buttons Power supply: 30 //48/4 V AC, 4 V DC Electrical connection: pluggable terminal block cable gland more technical details see data sheet ADI electronic in the brochure Z No responsibility taken for errors; 3

4 Electrical Connection DUK-...S300 DUK-...S30D N/O common N/C N/C N/O DUK- F3x0, DUK-...L3x3 DUK-...L443 n.c. signal out 3 signal out +V S DUK-...C30* DUK-...C34* switch out 0(4)-0 ma switch out switch out DUK-...E4R, DUK-...G4R Cable Connection DUK-...E34R, DUK-...G34R Plug Connection Wire number DUK-...E4R counter electronic +4 V DC +4 V DC DUK-...G4R dosing electronic 3 0(4)-0 ma 0(4)-0 ma 4 reset part quantity Control * 6 n. c. Control * 7 relay S relay S 8 relay S relay S 9 relay S relay S 0 relay S relay S * Control <-> : Start-Dosing Control <-> : Stop-Dosing Control <-> Control <-> : Reset-Dosing +4 V DC reset/ctr * U 4 3 d.c./ctr * 30 V AC/DC / A U S (4) - 0 ma out S 4 No responsibility taken for errors;

5 Order Details (Example: DUK- G4H S300 L) Model / Housing material Connection* Electronic Flow direction Switching S300 = relay, M-plug S30D = active 4 V DC, M-plug Frequency F300 = M-plug, 00 Hz F390 = M-plug, Hz DUK- = brass DUK- = st. st G4H = G ½ IG GH = G ¾ IG G6H = G IG G8H = G ½ IG G9H = G IG GBH = G 3 IG N4H = ½ NPT IG NH = ¾ NPT IG N6H = NPT IG Analogue L303 = M-plug, 0-0 ma L343 = M-plug, 4-0 ma L443 = DIN-plug, 4-0 ma Compact electronic C30R = x Open Collector, PNP C30M = x Open Collector, NPN C34P = 0(4)-0 ma, x Open Collector, PNP C34N = 0(4)-0 ma, x Open Collector, NPN ADI electronic Display Power supply Output Contacts B = bar graph 0 = 30 V AC 0 = without 0 = without L = from left to right R = from right to left T = from top to bottom B = from bottom to top N8H = ½ NPT IG N9H = NPT IG NBH = 3 NPT IG D = digital K = bar graph/ digital display A = dosing unit 4 = V AC = 48 V AC = 4 V AC 3 = 4 V DC = 0-0 V = 0-0 ma 4 = 4-0 ma = relay SPDT 6 = Open Collector Counter electronic E4R = LCD, 0(4)-0 ma, x relays, m cable E34R = LCD, 0(4)-0 ma, x relays, M-plug Dosing electronic G4R = LCD, 0(4)-0 ma, x relays, m cable G34R = LCD, 0(4)-0 ma, x relays, M-plug * Standard display in L/min, optional: display GPM (code G instead of H) Dimensions DUK-Sensor Model G/NPT SW H L B DUK-xxx4 ½ ca.7 DUK-xxx ¾ ca. 76 DUK-xxx ca. 80 DUK-xxx8 ½ ca. 90 DUK-xxx ca. 97 DUK-xxxB ca. No responsibility taken for errors;

6 Dimensions DUK- S30x, DUK- F3x0, DUK- L3x3 DUK- L443 8 Mx DUK- C3xx DUK- ExxR, DUK- GxxR Ø Mx ca DUK with ADI electronic OBOLD 6 No responsibility taken for errors;

DUK. Compact Ultrasonic Flowmeter

DUK. Compact Ultrasonic Flowmeter Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DVZ. Vortex Flowmeter Compact. for low viscosity liquids Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT

More information

DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max

More information

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit Model: DUK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water) Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p Resisitve Sensor hygienic design measuring monitoring analysing LTS Measuring range: -50 +250 C Accuracy Class A according to DIN IEC 751 p max : 10 bar Process connection: G ½ standard, G ½ or M cavity

More information

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0... Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

Level Sensors Reed Contact Chain

Level Sensors Reed Contact Chain Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"

More information

DVZ COMPACT VORTEX FLOWMETER

DVZ COMPACT VORTEX FLOWMETER DVZ COMPACT VORTEX FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.13-1.2 GPM to 2.7-26 GPM Accuracy: ±2.5 % of F.S. Vortex Shedding Technology with No Moving

More information

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ Operating Instructions for Compact Vortex Flow Meter Model: DVZ 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Electronic Flow Monitor

Electronic Flow Monitor Electronic Flow Monitor for Liquids measuring monitoring analysing Range: approx. 4200 cm/s Max. pressure: 100 bar Temperature of medium: 20...+80 C Option: 0...+120 C Processconnection: G 1 4...G 1 1

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Temperature Transmitters

Temperature Transmitters Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: 7.5... 5 V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault

More information

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA,

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, Compact Magnetic-Inductive Fowmeter for conductivity iquids measuring monitoring anaysing Fow MIK Range from iquids, acids and caustic soutions: 0.0...0 up to 40...800 L/min frequency-, switching-, anaogue

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C. Vane Flow Meter, Monitor, Counter, Batching System in modular design for liquids measuring monitoring analysing DF S 4 O O Measuring ranges: 0.08-0.50... 40-160 l/min water OO Measuring accuracy: ± 2.5%

More information

COMPACT-LINE. Transmitter for ph-value

COMPACT-LINE. Transmitter for ph-value Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK Operating Instructions for Compact Magnetic-Inductive Flow Meter Model: MIK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 5.1

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

Insertion Thermocouples with Bayonet Lock

Insertion Thermocouples with Bayonet Lock Insertion Thermocouples with Bayonet Lock measuring monitoring analysing Measuring ranges: 0... +400 C Bulbs in stainless steel 1.4571 NiCr-Ni or Fe-CuNi thermocouples Accuracy class 2 (option category

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

Through-beam ring sensors

Through-beam ring sensors Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable

More information

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue

More information

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting All-Metal Armored Variable Area Flowmeter and talizer for Horizontal or Vertical Mounting measuring monitoring analyzing BGF Measuring Range: 0.044...0.44 to 26.4...264 (Water) 0.176...1.76 to 100...1000

More information

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids measuring monitoring analysing : DF...D : DF...WM : DF...MA : DF...M Measuring ranges: 0.080.50 to 40160 water Measuring

More information

The compact test- disconnect terminal interface system for protection and secondary technology

The compact test- disconnect terminal interface system for protection and secondary technology POCON POWER Connector The compact test- disconnect terminal interface system for protection and secondary technology POCON the compact test-disconnect terminal interface system Safe control and testing

More information

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)

More information

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C Oval Wheel Flow Meter for viscous liquids measuring monitoring analysing OVZ Model: OVZ OMeasuring O ranges:.3-8....6-4 l/min liquid Measuring accuracy: ± 2.5% f.s. p max : 4 bar; t max : 8 Model: OVZ

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive iquids Flow and Temperature Measurement Switching, Transmitting, and

More information

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF Special versions up to 600 bar S2 Measuring range: 10-100... 4000-40000 l/h water

More information

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C Oscillation Flowmeter for gases measuring monitoring analysing DOG-4 Measuring ranges: 0.12-12... 60-6000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 200 Material: stainless

More information

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids Vane Flow Meter, Monitor, Counter, Batching System in Modular esign for Liquids measuring monitoring analysing : F... : F...WM : F...MA : F...M Measuring ranges: 0.080.50 to 40160 L/min water Measuring

More information

NBK-04. Level Indicator for Tank-Top Mounting

NBK-04. Level Indicator for Tank-Top Mounting Level Indicator for Tank-Top Mounting measuring monitoring analyzing NBK-04 Max. Measuring Length: 13' pmax: 230 PSI tmax: 250 F Max. Viscosity: 200 cps Connection: ASME B16.5 Flange 2" or 2-½" Material:

More information

Process Control HPP-25

Process Control HPP-25 Process Control HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software Industrie 4.0 ready...joining is our business worldwide! Process Control

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary Ultrasonic Flowmeter for Liquids Portable or Stationary measuring monitoring analyzing DUC Media: Ultrasonic Conducting Liquids Temperature Range: -40...300 F Accuracy: up to 1% Flow Velocities: 0...±

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Table of Contents Executive Summary 29

Table of Contents Executive Summary 29 Contents Table of Contents Executive Summary 29 Section 1: Introduction 33 Section 2: World 37 2.1.1. Main consumers 37 2.1.2. Main producers 2015 and 2016 39 2.1.3. Main importers 2015 and 2016 40 2.1.4.

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Process-Controller HPP-25

Process-Controller HPP-25 Process-Controller HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software... joining is our business Process-Controller HPP-25 Riveting process

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Operating Instructions for Microwave Level Switch. Model: LNM

Operating Instructions for Microwave Level Switch. Model: LNM Operating Instructions for Microwave Level Switch Model: LNM 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating Principle...4 6. Mechanical Connection...5

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Level switch Nivotemp NT-EL, NT-ELD

Level switch Nivotemp NT-EL, NT-ELD Level switch Nivotemp, Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored continuously. ere, modern factory automation requires compatible signals.

More information

Regulatory status for using RFID in the UHF spectrum 3 May 2006

Regulatory status for using RFID in the UHF spectrum 3 May 2006 Regulatory status for using RFID in the UHF spectrum 3 May NOTE: The following countries were updated since the last publication of 3 March : Thailand, Romania. The table attached provides an overview

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Inclinometer Selection Guide

Inclinometer Selection Guide POSITION AND MOTION SENSORS Inclinometer Selection Guide Page No. 1 GLOBAL PRESENCE FRABA Group Sales Partner America FRABA Inc. Hamilton, NJ, USA Asia FRABA Pte. Ltd. Singapore Europe POSITAL GmbH Cologne,

More information

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in Spires @caprosser 1 What do we want to know about the audience for academic blogging?

More information

Magnetic Inductive Flow Sensors induq. Series VMI

Magnetic Inductive Flow Sensors induq. Series VMI Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

onlinecomponents.com

onlinecomponents.com FF-SRE609 Extension Module FF-SR Series FEATURES Complies with the Machinery Directive 98/3/EC Meets the applicable parts of the US & Canadian regulations and standards ANSI/RIA/OSHA Redundant and positive-guided

More information

Brochure More information from

Brochure More information from Brochure More information from http://www.researchandmarkets.com/reports/1342464/ The World Market for Stranded Wire, Cable, Ropes, and Plaited Bands of Iron, Steel, Copper, or Aluminum Excluding Electrically

More information

Magnetic Inductive Flow Sensors VMI Series

Magnetic Inductive Flow Sensors VMI Series Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Characteristics Applications System Evaluation connection Media pressure temperature

More information

1204 Reflected Wave Reduction Device

1204 Reflected Wave Reduction Device Instructions 1204 Reflected Wave Reduction Device (Catalog Number 1204-RWR2-09-B, C) This publication will guide you through installation (including mounting, wiring and grounding procedures) of the 1204

More information

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa ABB Oy, KPM Sakeusmittaukset paperikoneen massanvalmistuksessa KPM Kajaani Process Measurements Ltd. KPM was established 2001 KPM was acquired by ABB on 2011, now Worldwide Sales and Service Network Researh

More information

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS Online data sheet FFUS15-1N1IO FFU A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Measurement principle Medium Ordering information Other models and accessories

More information

Monthly Summary of Troop Contribution to UN Operations

Monthly Summary of Troop Contribution to UN Operations Monthly Summary of Troop Contribution to UN Operations Month of Report : 3-Dec-3 Country Description of Post M F Totals ) Albania Individual Police............ 0 Subtotal for Country ) Algeria Experts

More information

M-2111 Series Ultrasonic Flow Meter

M-2111 Series Ultrasonic Flow Meter M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination

More information

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20 NEW Digital RGB Sensors CZ-V20 Series Lustre Detection Sensor Head CZ-H2 NEW SUPER RGB Sensor Lustre Detection Sensor Head is newly developed Glossy objects Digital RGB Sensor Amplifier CZ-V20 Matt objects

More information

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Catalogue NE 0506 FIXTURING SYSTEM Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Modular Zero Point Fixturing System 9000 Changes in Seconds Constant zero point without realignment

More information

Process Control Calibration Made Easy with Agilent U1401A

Process Control Calibration Made Easy with Agilent U1401A Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration

More information

High-Accuracy Surface Scanning Method

High-Accuracy Surface Scanning Method Surface Scanning Laser Confocal Displacement Meter LT-9000 Series First in the world High-Accuracy Surface Scanning Method High resolution of 0.3 µm The high-accuracy, surface scanning method allows measurements

More information

Welcome to the IFR Press Conference 30 August 2012, Taipei

Welcome to the IFR Press Conference 30 August 2012, Taipei Welcome to the IFR Press Conference 3 August 212, Taipei Continued success of the robotics industry Welcome by IFR President Dr. Shinsuke Sakakibara Presentation of the results of World Robotics 212 Industrial

More information

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS CONTROL CONCEPTS MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage UL: 24-600 Vac, 45-65 Hz CE: 24-690 Vac, 45-65 Hz AC Output 8, 16, 32, 50, 80, 100, 130, 160, 200, 240,

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

Indicator (4digit) (5digit) 8-pin plug counter

Indicator (4digit) (5digit) 8-pin plug counter 8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

WFS Fork Sensors. Agile and flexible ideal mounting for labeling applications. P r o d u c t I n f o r m at i o n

WFS Fork Sensors. Agile and flexible ideal mounting for labeling applications. P r o d u c t I n f o r m at i o n P r o d u c t I n f o r m at i o n Fork Sensors Agile and flexible ideal mounting for labeling applications Agile and flexible ideal mounting for labeling applications Product description At a glance Optimized

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

stripax The professional stripping tool

stripax The professional stripping tool stripax The professional stripping tool stripax the original: developed from experience Weidmüller is the world s leading manufacturer of solutions for electrical connectivity, transmission, conditioning

More information

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES 2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES 1. INTRODUCTION These HCT Transition Period Official Competition Rules ( Official Rules ) govern how players earn Hearthstone Competitive Points

More information

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges W : iniature Photoelectric Switch Series with Large Scanning Ranges Photoelectric proximity switch with adjustable scanning distance and background suppression (BGS): Scanning distance = adjustable up

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter LENORD +BAUER... automates motion. Technical information Version 01.12 General Multiturn absolute rotary encoders

More information