DUK. Compact Ultrasonic Flowmeter

Size: px
Start display at page:

Download "DUK. Compact Ultrasonic Flowmeter"

Transcription

1 Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: GPM to GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F Connections: ½"...3" NPT or G Thread Material: Brass or 36 Stainless Steel Outputs: Analog, Frequency, Switching, Compact Electronics with Digital Displays, Batching and Totalizing Electronics 0/07-04 KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM KOBOLD Instruments, Inc. 80 Parkway View Drive Pittsburgh, PA 0 Main Office: info@koboldusa.com

2 Description The KOBOLD model DUK fl ow meters are used for measuring, monitoring, metering, and batching of low viscosity liquids. They are highly repeatable, feature a small pressure loss, and offer measurement independent of density and temperature changes. The devices work on the principle of run time difference. Ultrasonic waves in the media are infl uenced by the rate of fl ow. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of the ultrasonic signals. If there is no fl ow, the run times of both signals are identical. If the media is fl owing, then the run time of the signal against the fl ow is longer than the signal with fl ow. The run time difference, which is determined by a microprocessor, is proportional to the rate of fl ow. The devices can be equipped with a switching, a frequency, or an analog. In addition, a compact electronic can be selected that features a digital display, a switching, and an analog. The device series is rounded off by an optionally available batching or totalizing electronic. The meter electronic indicates the momentary fl ow rate in the fi rst line of the display and the partial or total fl ow in the second line. A batching electronic controls simple fi lling tasks and similarly measures fl ow rates, total amounts, and fi lling amounts. The analog and two relay s can be used for further processing of the signals. Common applications include: machine building, automotive, robotics, cooling, and hot water. T V m C L Electronic T Technical Details Measuring Principle: Range: Media: Viscosity: Accuracy: Repeatability: Mounting Position: Straight Piping: Ultrasonic See Table Liquids with Max. % Solid Max. 3 cst ±0.7% of Reading + ±0.7% of F.S. ±0.% of F.S. Universal: Flow in Direction of the Arrow (Horizontal: Electronic on Top or Below) 0 x Pipe Diameter In/Out Media Temperature: F F (High Temp Version) Ambient Temperature: F Response Time: Approx s (Depending on Electronic Version) Max Pressure: 30 PSI Pressure Loss: Max.. PSI at F.S. Protection: IP 6 Wetted Parts Sensor Housing: Brass or 36 Stainless Steel Sensors: PEEK Seal: NBR for Standard Version FKM for High Temp Version (Others upon Request) Measuring Ranges and Weights Model Measuring Range "G" (GPM) Measuring Range "H" (LPM) Size (NPT/G) DUK-...S30x DUK- F3x0 DUK-...Lx43 DUK-...C3xx DUK-...Ex4R DUK-...Gx4R DUK with ADI 4 V DC DUK with ADI 30 / V AC DUK-xxx ½.87 LB.3 LB.0 LB 4.74 LB.9 LB DUK-xxx ¾.3 LB.76 LB.6 LB.8 LB 6.39 LB DUK-xxx LB 3.64 LB 3.3 LB 6.06 LB 7.8 LB DUK-xxx ½.8 LB.6 LB. LB 8.0 LB 9.6 LB DUK-xxx LB 8.8 LB 8.7 LB.4 LB.46 LB DUK-xxxB LB 6.09 LB.98 LB 8. LB 9.73 LB

3 Electrical Specifications DUK-..S300, DUK-..S30D (Switching Output) Bi-color LED for Switch Status Switching Output (..S300): SPDT Relay, max. A / 30 V DC Switching Output (..S30D): Active 4 V DC, N/C and N/O Switch Point: % of f.s. in 0 % Steps, Confi gurable by the Customer Using a Rotary Switch ± 0 % Power Consumption: 30 ma Electrical Connection: Plug M x Max Range Overflow: Flashing Bi-color LED from 0% of full scale DUK-..F300, DUK-..F390 (Frequency Output) Pulse Output: PNP, Open Collector, max. 00 ma Frequency at F.S.: 00 Hz (..F300) 0 to 000 Hz (..F390) User Specifi ed ± 0 % Power Consumption: ma Electrical Connection: Plug M x Max Range Overflow: Frequency approx k from 0% of full scale DUK-..L343 (Analog Output) Analog Output: 4-0 ma, 3-wire Max. 00 Ω ± 0 % Power Consumption: Max. 4 ma Electrical Connection: Plug M x DUK-..Ex4R (Totalizing Electronic) LCD, x 8 Digits, Illuminated Rate, Total and Grand Total, Units Selectable Analog Output: 4-0 ma Adjustable Max. 00 Ω Switching Output: Relay (x), Max. 30 V/ A, 60 VA Via 4 Buttons Functions: Reset, MIN/MAX Memory, Flow Rate, Total and Grand Total, Language ± 0 %, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable Connection or Mx Plug DUK-..Gx4R (Batching Electronic) LCD, x 8 Digits, Illuminated Batching, Total and Grand Total, Units Selectable Analog Output: 4-0 ma, Adjustable Max. 00 Ω Switching Output: Relay (x), Max. 30 V / A, 60 VA Via 4 Buttons Functions: Batching (Relay S), Start, Stop, Reset, Fine Batching, Correction Amount, Flow Switch, Total Quantity, Language ± 0 %, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable Connection or M Plug DUK-..L443 (Analog Output) Output: 4-0 ma, 3-wire Max. 00 Ω ± 0 % Power Consumption: Max. 4 ma Electrical Connection: Plug DIN 4360 DUK-..C3xx (Compact Electronic) 3-digit LED Analog Output: 4-0 ma Adjustable (only DUK-..C34x) Max. 00 Ω Switching Output: (x) Semiconductor PNP or NPN Contact Function: N/C-N/O-Frequency Programmable (Approx. 400 Hz at F.S., Uncalibrated) Via Buttons ± 0 % Power Consumption: Approx. 00 ma Electrical Connection: Plug M x DUK-..Kxx (ADI- Electronic) Bar Graph and -Digit Digital Combination Display; Batch System Analog Output: 4-0 ma, 0-0 V Switching Output: x Relays / SPDT Max. 0 V AC, A Resistive Load Max. 30 V DC / A Via 4 Buttons Power Supply: V AC, ±0% or 8-30 V AC /0-40 V DC Electrical Connection: Terminal Block via Cable Gland 3

4 Order Details (Example: DUK- N4 G S300 L) Note: Flow range determined by fi tting size and can be referenced on the measuring range and weight table located on page Model / Housing Material Connection* Output / Electronic Flow Direction Switching Output..S300.. = Relay, M-Plug..S30D.. = Active 4 V, M-Plug DC Frequency Output..F300.. = M-Plug, 00 Hz..F390.. = M-Plug, 0 to 000 Hz (User Specifi ed)..n4g.. = ½" NPT Analog Output..NG.. = ¾" NPT..L343.. = M-Plug, 4-0 ma..n6g.. = " NPT..L443.. = DIN-Plug, 4-0 ma..l = from Left to DUK-.. = Brass..N8G.. = ½" NPT Right Compact Electronic DUK-.. = SS..N9G.. = " NPT..C30R.. = Open Collector, PNP (x)..r = from Right to..nbg.. = 3" NPT..C30M.. = Open Collector, NPN (x) DUK-.. = High Left..C34P.. = 0 ma, Open Collector, PNP Temp...G4G.. = G ½ Brass..C34N.. = 4-0 ma, Open Collector, NPN..GG.. = G ¾..T = from Top to ADI Electronic Bottom DUK-.. = High..G6G.. = G Temp. Display Power Supply Output Contacts SS..G8G.. = G ½..B = from Bottom to K = Bar Graph/ 0 = V 0 = without AC/DC..G9G.. = G = (x) Relay Top digital 3 = 8-30 V 4 = 4-0 ma, AC..GBG.. = G 3 SPDT display 0-40 V 0-0 VDC Totalizing Electronic..E4R.. = LCD, 4-0 ma, Relay (x), m Cable..E34R.. = LCD, 4-0 ma, Relay (x), M-Plug (x) Batching Electronic..G4R.. = LCD, 4-0 ma, Relay (x), m Cable..G34R.. = LCD, 4-0 ma, Relay (x), M-Plug (x) DC Accessories: P/N = 4-Pin Micro-DC Connector with 6-foot Cable for Output Types F300, F390, L 343, & S30D P/N = -Pin Micro-DC Connector with 6-foot Cable for Output Types C3xx, S300, E34R, & G34R P/N = 8-Pin Micro-DC Connector with 6-foot Cable for Output Types E34R & G34R *Standard display in G/min, optional display L/min (code H instead of G) Dimensions DUK-Sensor Model G/NPT SW H L B DUK-xxx4 ½ ca..83 DUK-xxx ¾ ca..99 DUK-xxx ca. 3. DUK-xxx8 ½ ca. 3.4 DUK-xxx ca. 3.8 DUK-xxxB ca

5 Dimensions (mm) DUK-..S30x, DUK-..F3x0, DUK-..L343 DUK-..L443 8 Mx DUK-..C3xx DUK-..Ex4R, DUK-..Gx4R Ø Mx ca DUK with ADI Electronic

6 Electrical Connection DUK-..S300 DUK-..S30D N/O common N/C N/C N/O DUK-..F3x0, DUK-..L343 DUK-..L443 n.c. signal out 3 signal out +V S DUK-..C30* DUK-..C34* switch out 0(4)-0 ma switch out switch out DUK-...E4R, DUK-...G4R Cable Connection DUK-..E34R, DUK-..G34R Plug Connection Wire Number DUK-..E4R Totalizing Electronic DUK-..G4R Batching Electronic 4 V DC 4 V DC -0 ma 4-0 ma 4 Reset Total Part Control * 6 n. c. Control * 7 Relay S Relay S 8 Relay S Relay S 9 Relay S Relay S 0 Relay S Relay S * Control <-> : Start-Batching Control <-> : Stop-Batching Control <-> Control <-> : Reset-Batching +4 V DC reset/ctr * U 4 3 d.c./ctr * 30 V AC/DC / A U S (4) - 0 ma out max. 00 Ω S 6

DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max

More information

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: 0.08-0. - 630 L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection:

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DVZ. Vortex Flowmeter Compact. for low viscosity liquids Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT

More information

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water) Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and

More information

DVZ COMPACT VORTEX FLOWMETER

DVZ COMPACT VORTEX FLOWMETER DVZ COMPACT VORTEX FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.13-1.2 GPM to 2.7-26 GPM Accuracy: ±2.5 % of F.S. Vortex Shedding Technology with No Moving

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit Model: DUK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0... Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,

More information

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ Operating Instructions for Compact Vortex Flow Meter Model: DVZ 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive iquids Flow and Temperature Measurement Switching, Transmitting, and

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:

More information

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p Resisitve Sensor hygienic design measuring monitoring analysing LTS Measuring range: -50 +250 C Accuracy Class A according to DIN IEC 751 p max : 10 bar Process connection: G ½ standard, G ½ or M cavity

More information

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"

More information

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting All-Metal Armored Variable Area Flowmeter and talizer for Horizontal or Vertical Mounting measuring monitoring analyzing BGF Measuring Range: 0.044...0.44 to 26.4...264 (Water) 0.176...1.76 to 100...1000

More information

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max

More information

Through-beam ring sensors

Through-beam ring sensors Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C. Vane Flow Meter, Monitor, Counter, Batching System in modular design for liquids measuring monitoring analysing DF S 4 O O Measuring ranges: 0.08-0.50... 40-160 l/min water OO Measuring accuracy: ± 2.5%

More information

Level Sensors Reed Contact Chain

Level Sensors Reed Contact Chain Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Electronic Flow Monitor

Electronic Flow Monitor Electronic Flow Monitor for Liquids measuring monitoring analysing Range: approx. 4200 cm/s Max. pressure: 100 bar Temperature of medium: 20...+80 C Option: 0...+120 C Processconnection: G 1 4...G 1 1

More information

NBK-04. Level Indicator for Tank-Top Mounting

NBK-04. Level Indicator for Tank-Top Mounting Level Indicator for Tank-Top Mounting measuring monitoring analyzing NBK-04 Max. Measuring Length: 13' pmax: 230 PSI tmax: 250 F Max. Viscosity: 200 cps Connection: ASME B16.5 Flange 2" or 2-½" Material:

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK Operating Instructions for Compact Magnetic-Inductive Flow Meter Model: MIK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 5.1

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Temperature Transmitters

Temperature Transmitters Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: 7.5... 5 V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault

More information

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary Ultrasonic Flowmeter for Liquids Portable or Stationary measuring monitoring analyzing DUC Media: Ultrasonic Conducting Liquids Temperature Range: -40...300 F Accuracy: up to 1% Flow Velocities: 0...±

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

The compact test- disconnect terminal interface system for protection and secondary technology

The compact test- disconnect terminal interface system for protection and secondary technology POCON POWER Connector The compact test- disconnect terminal interface system for protection and secondary technology POCON the compact test-disconnect terminal interface system Safe control and testing

More information

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA,

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, Compact Magnetic-Inductive Fowmeter for conductivity iquids measuring monitoring anaysing Fow MIK Range from iquids, acids and caustic soutions: 0.0...0 up to 40...800 L/min frequency-, switching-, anaogue

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B Rev012008 USER MANUAL DEI MODEL USFT-B USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER The Model USFT-B is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

COMPACT-LINE. Transmitter for ph-value

COMPACT-LINE. Transmitter for ph-value Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Magnetic Inductive Flow Sensors VMI Series

Magnetic Inductive Flow Sensors VMI Series Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive

More information

Magnetic Inductive Flow Sensors induq. Series VMI

Magnetic Inductive Flow Sensors induq. Series VMI Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

Electronic Temperature Transmitters

Electronic Temperature Transmitters Electronic Temperature Transmitters ELECTRONIC TEMPERATURE TRANSMITTERS As with the pressure transmitters, HYDAC ELECTRONIC also has temperature transmitters appropriate for every application. The transmitters

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Process Control HPP-25

Process Control HPP-25 Process Control HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software Industrie 4.0 ready...joining is our business worldwide! Process Control

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Catalogue NE 0506 FIXTURING SYSTEM Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures Modular Zero Point Fixturing System 9000 Changes in Seconds Constant zero point without realignment

More information

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C Oval Wheel Flow Meter for viscous liquids measuring monitoring analysing OVZ Model: OVZ OMeasuring O ranges:.3-8....6-4 l/min liquid Measuring accuracy: ± 2.5% f.s. p max : 4 bar; t max : 8 Model: OVZ

More information

Insertion Thermocouples with Bayonet Lock

Insertion Thermocouples with Bayonet Lock Insertion Thermocouples with Bayonet Lock measuring monitoring analysing Measuring ranges: 0... +400 C Bulbs in stainless steel 1.4571 NiCr-Ni or Fe-CuNi thermocouples Accuracy class 2 (option category

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Inclinometer Selection Guide

Inclinometer Selection Guide POSITION AND MOTION SENSORS Inclinometer Selection Guide Page No. 1 GLOBAL PRESENCE FRABA Group Sales Partner America FRABA Inc. Hamilton, NJ, USA Asia FRABA Pte. Ltd. Singapore Europe POSITAL GmbH Cologne,

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids measuring monitoring analysing : DF...D : DF...WM : DF...MA : DF...M Measuring ranges: 0.080.50 to 40160 water Measuring

More information

2-channel speed sensor GEL 247 Compact sensor for harsh applications

2-channel speed sensor GEL 247 Compact sensor for harsh applications 2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Process-Controller HPP-25

Process-Controller HPP-25 Process-Controller HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software... joining is our business Process-Controller HPP-25 Riveting process

More information

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20 NEW Digital RGB Sensors CZ-V20 Series Lustre Detection Sensor Head CZ-H2 NEW SUPER RGB Sensor Lustre Detection Sensor Head is newly developed Glossy objects Digital RGB Sensor Amplifier CZ-V20 Matt objects

More information

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa ABB Oy, KPM Sakeusmittaukset paperikoneen massanvalmistuksessa KPM Kajaani Process Measurements Ltd. KPM was established 2001 KPM was acquired by ABB on 2011, now Worldwide Sales and Service Network Researh

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS CONTROL CONCEPTS MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage UL: 24-600 Vac, 45-65 Hz CE: 24-690 Vac, 45-65 Hz AC Output 8, 16, 32, 50, 80, 100, 130, 160, 200, 240,

More information

Table of Contents Executive Summary 29

Table of Contents Executive Summary 29 Contents Table of Contents Executive Summary 29 Section 1: Introduction 33 Section 2: World 37 2.1.1. Main consumers 37 2.1.2. Main producers 2015 and 2016 39 2.1.3. Main importers 2015 and 2016 40 2.1.4.

More information

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter LENORD +BAUER... automates motion. Technical information Version 01.12 General Multiturn absolute rotary encoders

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information