KDS. All Metal Variable Area Flowmeter. for Liquids and Gases
|
|
- Chrystal Kelley
- 5 years ago
- Views:
Transcription
1 All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : water 3-30 Nm3/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼" NPT thread ( valve) Material: Stainless steel Contacts, analogue output (al) KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDO- NESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM KOBOLD Messring GmbH Nordring D Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com 1
2 Function The fl ows from bottom to top through the meter tube of the fl ow meter. The fl oat is lifted until an annular gap between the measuring cone and the fl oat is produced which corresponds to the fl ow. The forces acting on the fl oat are in equilibrium. Technical Details Materials Measuring cone, fl oat, armature: Sealing: Stainless steel other materials on request (special on request) The height of the fl oat resulting from the fl ow rate is transmitted by the permanent magnet in the fl oat through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit. The variable-area fl owmeter consists of a stainless steel device with an integrated conical stainless steel measuringtube and a vertically movable fl oat. The valve for setting the fl ow rate is built-in (only -K/C). Appli The meter is suitable for fl ow measurement of liquid or gaseous products in pipes. It shows the current fl ow rate in volume or mass per unit in time. Areas of Appli Flow measurement of liquids and gases Dosing Can be used in the chemical industry or in medical or laboratory engineering Robust mechanical system with a low rate of wear The devices are available with additional electrical equipment for process monitoring and control Design for horizontal and vertical connections available A variety of sealing materials Wall mounting possibility (-C) Flow Controller () High pressure appli () Process connection: ¼" NPT (F), adapter for other connections available special connections on request Nominal pressure: PN 40 (-K, C) PN 64 (-S) al up to 420 bar (-S) Accuracy Liquid/gas: ±3 % qg 50 acc. VDE/VDI 3513 Process temperature: -40 C C ( switch/electronic) limit switch: NJ 1, 5-6, 5N -25 C C NJ 2-11 SN C -40 C C (c/w electronic -... E) Ambient temperature: -25 C C Weight: 0.65 kg Protecion: IP 65 (EN60529) Certificate and Approval Explosion protection: BVS 03 ATEX H/B 113 Pressure drop: [H 2 O/mbar] -S... -K/C... A B C D 8 10 E F G H I J 50 - K 80 - Reference condition: according to IEC 770, water at complete opened valve 2
3 Display: Electrical outputs: Limit s: Analogue output (- E): %- measuring range Ambient temperature: -25 C C 1 up to max. 2 inductive limit s, NAMUR (Pepperl & Fuchs NJ N); 8.2 V (R i ~1 KΩ) (NJ SN); 5 25 V DC ( wiring) , 2-wire, passive; V; burden max. 500 Ω version Ex (intrinsically safe) electrical connection via M12 plug Certifi and Approvals Explosion protection: NJ1,5-6,5N PTB 00 ATEX 2048 X II 2G Ex ia IIC T6-T4 NJ 2-11SN PTB 00 ATEX 2049 X II 2G Ex ia IIC T6-T4 ZELM 03 ATEX 0128 X II 1D Ex iad 20 T... C -(E) II 2G Ex ib IIC T4 Gb, II 2D Ex ib IIIC T 135 C Db CE-Marking: Explosion Protection Directive 94/9/EC, PED 97/23/EG Electromagnetic compatibility for add-on electrical sensors: SIL: EMC-Directive 2004/108/EG EN :2006 SIL conformity acc. IEC :2000 and IEC :2010, declaration of conformity as separate document available Connection vertical -S... (Example: -SA P 30 A 00) SA SB SC SD SE SF SG SH SI SJ SK... Special Special -SX... X = special H 2 O E = MR- F = double specifi 1/
4 Connection horizontal -K... (Example: -KA P 30 A 00) KA KB KC KD KE KF... 4, KG... 6, KH KI... Special Special -KX... U0 = ¼ NPT bottom OO = ¼ NPT top H 2 O E = MR-Scale F = Double acc. to Connection horizontal for wall mounting -C... (Example: -CA P 30 A 00) CA CB CC CD CE CF CG CH CI... Special Special -CX... U0 = ¼ NPT bottom OO = ¼ NPT top H 2 O E = MR-Scale F = Double acc. to 4
5 Dimensions -K, C min. 92 max. 102 ¼" NPT 122, D: 1000 kg/m³ T: V: 1m/Pas P: 40 bar über ¼" NPT S ¼"NPT ( ) D SW D: 1000kg/m³ T: V: 1 m/pas P: 40 bar über , ,5 D 1/
Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...
Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000
More informationBGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases
All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy
More informationFull Metal Variable Area Flowmeter and Counter Model BGF
Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20
More informationMagnetic Inductive Flowmeter
Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationTME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C
Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More informationLTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p
Resisitve Sensor hygienic design measuring monitoring analysing LTS Measuring range: -50 +250 C Accuracy Class A according to DIN IEC 751 p max : 10 bar Process connection: G ½ standard, G ½ or M cavity
More informationDVZ. Vortex Flowmeter Compact. for low viscosity liquids
Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT
More informationElectromagnetic flowmeter in all metal design Model MIM
Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and
More informationKAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...
Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,
More informationDUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit
Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: 0.08-0. - 630 L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection:
More informationLCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version
Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement
More informationBGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting
All-Metal Armored Variable Area Flowmeter and talizer for Horizontal or Vertical Mounting measuring monitoring analyzing BGF Measuring Range: 0.044...0.44 to 26.4...264 (Water) 0.176...1.76 to 100...1000
More informationBGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF Special versions up to 600 bar S2 Measuring range: 10-100... 4000-40000 l/h water
More informationLevel Sensors Reed Contact Chain
Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:
More informationLiquid Level Switches
Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,
More informationTemperature Transmitters
Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: 7.5... 5 V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault
More informationNGR. Guided Wave Radar Level Transmitter
Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer
More informationDUK. Compact Ultrasonic Flowmeter
Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F
More informationMIM. Electromagnetic Flowmeter. Compact, All-metal Design
Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and
More informationTUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)
Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%
More informationElectronic Flow Monitor
Electronic Flow Monitor for Liquids measuring monitoring analysing Range: approx. 4200 cm/s Max. pressure: 100 bar Temperature of medium: 20...+80 C Option: 0...+120 C Processconnection: G 1 4...G 1 1
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationCOMPACT-LINE. Transmitter for ph-value
Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationPSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs
Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationThrough-beam ring sensors
Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationFrame through-beam sensors
Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationEXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X
KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue
More informationS 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.
Vane Flow Meter, Monitor, Counter, Batching System in modular design for liquids measuring monitoring analysing DF S 4 O O Measuring ranges: 0.08-0.50... 40-160 l/min water OO Measuring accuracy: ± 2.5%
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationOperating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601
Operating Instructions for Pressure Sensor with Ceramic Sensor Element Model: SEN-9601 We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationProcess Control HPP-25
Process Control HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software Industrie 4.0 ready...joining is our business worldwide! Process Control
More informationDensity meter DWF. Device description. Device description DWF Page 1 of 22
Density meter DWF Device description Device description DWF Page 1 of 22 Table of Contents 1. Definition of the device 4 1.1 Vendor / Manufacture 4 1.2 Product type and designation 4 1.3 Manual issue date
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationInsertion Thermocouples with Bayonet Lock
Insertion Thermocouples with Bayonet Lock measuring monitoring analysing Measuring ranges: 0... +400 C Bulbs in stainless steel 1.4571 NiCr-Ni or Fe-CuNi thermocouples Accuracy class 2 (option category
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationConnection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition
solated switch amplifier Output: relay Connection Control circuit EEx ia C 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short-circuit LK and interruption LB) with LED indicator
More informationCOMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z
KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationInclinometer Selection Guide
POSITION AND MOTION SENSORS Inclinometer Selection Guide Page No. 1 GLOBAL PRESENCE FRABA Group Sales Partner America FRABA Inc. Hamilton, NJ, USA Asia FRABA Pte. Ltd. Singapore Europe POSITAL GmbH Cologne,
More informationKFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite
KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationMIM. Electromagnetic Flowmeter. Compact, All-metal Design
Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive iquids Flow and Temperature Measurement Switching, Transmitting, and
More informationCOMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z
KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationRelative pressure transmitter type 522 for shipbuilding
Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 1000 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology
More informationUser Manual for 24 GHz Blind-Spot Radar Sensor
User Manual for 24 GHz Blind-Spot Radar Sensor SRR2-A Department: 1 of 13 AUTHORS Name Organisation Section Frank Gruson Continental, Frequency Management WW Issue Document Date of Issue Document Owner
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationDOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C
Oscillation Flowmeter for gases measuring monitoring analysing DOG-4 Measuring ranges: 0.12-12... 60-6000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 200 Material: stainless
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More information2-channel speed sensor GEL 247 Compact sensor for harsh applications
2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation
More informationThe compact test- disconnect terminal interface system for protection and secondary technology
POCON POWER Connector The compact test- disconnect terminal interface system for protection and secondary technology POCON the compact test-disconnect terminal interface system Safe control and testing
More informationPositioner with HART Communication Type 3780
Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels
More informationAbsolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160
Mechatronic pressure measurement Absolute pressure gauge with output signal For the process industry Models APGT43.100 and APGT43.160, NS 100 and 160 k Applications for further approvals see page 4 WIKA
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationTarget disk flowmeters Series DP Metallic flowmeter for liquids and gases
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationIndicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN
Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm
More informationAny installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.
General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845
More informationAssembly. Front view. HiC2441. SL2 1b. Termination Board
SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General
More informationSignal conditioner - MACX MCR-UI-UI-NC
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationResistance thermometer Model TR31, miniature design
Electrical temperature measurement Resistance thermometer Model TR31, miniature design WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationDS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor
GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent
More informationNBK-04. Level Indicator for Tank-Top Mounting
Level Indicator for Tank-Top Mounting measuring monitoring analyzing NBK-04 Max. Measuring Length: 13' pmax: 230 PSI tmax: 250 F Max. Viscosity: 200 cps Connection: ASME B16.5 Flange 2" or 2-½" Material:
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationMiniature resistance thermometer Model TR33, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationProcess-Controller HPP-25
Process-Controller HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software... joining is our business Process-Controller HPP-25 Riveting process
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationMiniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B
Temperature Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B WIKA data sheet TE 60.27 further approvals see page 12 Applications Sanitary applications Food and
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationSALES SERVICE +358 (0)
SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationMiniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding
Electrical temperature measurement Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding WIKA data sheet TE 60.27 further approvals see page 12 Applications Sanitary
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More information