1 SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics: Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance Sens connection without any external jumpers inputs (e.g. f sens redundancy difference fmation) outputs (U and / I) inputs can be linked with each other and allocated to the outputs which enables calculations and sens moniting (e.g. prognostic maintenance of senss). System capability: Communication via Modbus interface Freely programmable relay, e.g. f limit alarm signalling AC/DC wide-range power supply unit Pluggable high-quality screw terminals All settings of the instrument can be adapted to the measuring task by PC software. The software also serves visualising, commissioning and service Table : Input variables, measuring ranges Type of measurement Measuring range Minimum span DC voltage [mv] mv mv DC voltage [V] V > V DC current [ma] ma 0. ma Resistance [Ω] Ω Ω RTD Pt C 0 K RTD Ni C 5 K TC Type B C 65 K TC Type E C K TC Type J C 9 K Type of measurement Measuring range Minimum span TC Type K 0... C 50 K TC Type L C K TC Type N C K TC Type R C 59 K TC Type S C 65 K TC Type T C 50 K TC Type U C 9 K TC Typ W5Re-W6Re C 5 K TC Type WRe-W5Re C 6 K Camille Bauer Data sheet V 60s Le 06.0

2 SINEAX V 60s Technical data Measuring input Direct voltage Measuring range mv F limits see table Ri > 0 MΩ, continuous overload max. ±00 mv Measuring range V F limits see table Ri =. MΩ, continuous overload max. ±00 V Direct current Measuring range ma F limits see table Ri = Ω, continuous overload max. ±50 ma Resistance thermometer RTD Resistance measurment types Pt00 (IEC 605), adjustable Pt0 Pt000 Ni00 (DIN 60), adjustable Ni50 Ni000 Measuring range limits See table, -wire connection Measuring current 0. ma Line resistance 0 Ω per line, in -wire connection adjustable calibratable Thermocouples TC Thermocouples Type B, E, J, K, N, R, S, T (IEC 605-) Type L, U (DIN 60) Type W5Re-W6Re, WRe- W5Re (ASTM E9-90) Measuring range limits See Table Cold junction compensation Internal (with installed Pt00), with Pt00 on terminals, external with reference junction thermostat 0 0 C Resistance measurement, teletransmitter, potentiometer Measuring range limits See table, -wire connection Resistance teletransmitter Type WF and WF DIN Measuring current 0. ma Line resistance 0 Ω per line, in -wire connection adjustable calibratable Measuring input Direct voltage Measuring range mv Same as measuring input Resistance thermometer RTD Same as measuring input except: wire connection Thermocouples TC Same as measuring input Resistance measurement, teletransmitter, potentiometer Same as measuring input except: wire connection Please note The direct voltage measuring range V and direct current ma types of measurement can also be allocated to input as input variable in the instrument confi guration. However, as input wiring they are only available once. The measuring inputs and are galvanically connected. In case of senss, please observe the wiring instruction in the operating manual! Analog outputs and The two outputs are galvanically connected and have a common earth. Voltage and current output software-confi gurable. Direct current Output range ± 0 ma, range may be freely set Burden voltage max. V Open circuit voltage < 0 V Limit Adjustable, max. ± ma Residual ripple <% pp related to 0 ma Direct voltage Output range ± 0 V, range may be freely set Load max. 0 ma Current limit Approx. 0 ma Limit Adjustable, max. ± V Residual ripple <% pp related to 0 V Output settings Limit Gain/offset trimming Inversion Relay contact output Contact Switching capacity pole, nmally open contact AC: A / 50 V AC DC: A / 0 V Bus/programming connection Interface, protocol RS-5, Modbus RTU Baudrate kbaud, adjustable Transmission behaviour Measured quantities f the outputs Input Input Input + input Input input Input input Input input Minimum value, maximum value mean value of input and input Sens redundancy Input input Datenblatt V 60s Le 06.0 Camille Bauer

3 SINEAX V 60s Transmission function Settling time: Linear, user-specifi c via basic value table ( basic values per measured variable) Adjustable 0 s Limit values and moniting Limit values and Number Measured variable f the limit values Input Input Measured variable f outputs Input input (e.g. drift moniting in case of senss) Input input (e.g. drift moniting in case of senss) Functions Absolute amount Gradient dx/dt (e.g. temperature gradient moniting) Time delay Adjustable s Signalling Relay contact, alarm LED, status Sens breakage and sht circuit moniting measuring input Signalling Relay contact, alarm LED, status Output value in case of a fault Other moniting operations Drift moniting Moniting of measured value difference between input senss f a certain period of time (e.g. due to different sens response times). If the limit value is exceeded f this time, an alarm is signalled. (See limit values and ) Sens redundancy Measurement with temperature senss; if sens fails (fault) sens is activated f bridging (see measuring quantities f outputs) Power supply Rated voltage UN Tolerance 0 V DC ±5% 00 0 V AC, Hz ±5% Displays at the instrument LEDs in front plate Power ON: Green LED Relay contact: Yellow LED Alarm: Red LED Configuration, programming Operation with PC software «CB-Manager» Accuracies (accding to EN/IEC 600-) Reference conditions Ambient temperature Power supply Reference value Settings C ± K V DC Span Input : Direct voltage mv, mv Output : 0 ma, burden resistance 00 Ω Mains frequency 50 Hz, Setting time s Input, output, relay, moniting off not active, f voltage output: range V, burden resistance kω Basic accuracy At reference conditions ±0.% Other types of measurement and input ranges: RTD Pt00, Ni00 ±0.% ±0. K Resistance measurement ±0,% ±0. Ω TC Type K, E, J, T, N, L, U ±0.% ±0. K, meas. value > 00 C TC Type R, S ±0.% ±. K TC Type B ±0.% ±. K, meas. value > 00 C TC W5Re-W6Re, WRe-W5Re ±0.% ±.0 K DC voltage mv ±0.% ±0.05 mv DC voltage V ±0.% ±0.005 V DC current ma ±0.% ±0.005 ma Alarm signalling Relay contact Alarm LED Time delay Output value in case of a fault With closed contact, the yellow LED shines, invertible Adjustable 0 60 s F sens breakage and sht circuit, value adjustable 0 0% Additional err (additive) High range minimum value (Minimum value >0% of maximum value): ±0.% of maximum value Small output range ±0.% * (reference range / new range) Cold junction compensation internal ± K Camille Bauer Datenblatt V 60s Le 06.0

4 SINEAX V 60s Influencing facts Ambient temperature ±0.% per 0 K at reference conditions other settings: basic accuracy and additional errs per 0 K Long-term drift ±0.% Common mode/ series mode infl uence ±0.% Ambient conditions Operating temperature C Stage temperature 0 +0 C Relative humidity Annual average 5%, no dew Range of utilisation Internal room up to 000m above sea level Installation details Design Top-hat rail housing U Combustibility class V-0 accding to UL 9 Dimensions See dimensional drawing Assembly F snap-on fastening on top-hat rail (5 x 5 mm 5 x.5 mm) accding to EN 50 0 Terminals Pluggable,.5 mm Weight 0. kg Electric connections Table : Connection of inputs Type of measurement Circuit Terminal Remarks Measuring input Output Output Relay contacts Power supply Bus/ programming connection to (+), ( ) 0 (+), ( ) 9, 5 (+/~) 6 ( /~) See table +,, GND Front plug Input Input Product safety, regulations Electromagnetic compatibility Ingress protection (acc. IEC 59 EN 6059) EN / Housing IP 0 terminal IP0 Direct voltage mv U [mv] Electric design Acc. IEC EN 600 Degree of pollution Between power supply and all circuits and between the measuring input ( + ) and all circuits Reinfced insulation overvoltage categy III Wking voltage 00 V Test voltage. kv AC rms Thermocouple with external cold junction thermostat internally compensated Between output ( + ) and relay contact Between output ( + ) and the bus connection Reinfced insulation overvoltage categy II Wking voltage 00 V Test voltage. kv AC rms Functional insulation Wking voltage <50 V Test voltage 0.5 kv AC rms Environmental tests EN /-/-/-6/- Thermocouple with Pt00 at the terminals at the same input Pt00 Thermocouple with Pt00 at the terminals at the other input Pt00 Datenblatt V 60s Le 06.0 Camille Bauer

5 SINEAX V 60s Type of measurement Input Input Dimensional drawing Resistance thermometer resistance measurement -wire RTD, R 0 Resistance thermometer resistance measurement -wire RTD, R.5 0 Resistance thermometer resistance measurement -wire RTD, R Ra 0% Rd Resistanceteletransmitter WF 00% Re Resistanceteletransmitter WF-DIN Ra Rd Re 0% 00% Scope of supply SINEAX V60s Safety Instructions 6 50 Software and Docu-CD 56 0 Accessies USB-RS5 converter (f programming the V60s) Article No. 6 9 Ordering details Version Order code Article No. Standard 60s-0 G 69 With test certifi cate 60s-D G in German With test certifi cate in English 60s-E G Direct voltage V U [V] 6 Direct current ma I [ma] 5 Camille Bauer Datenblatt V 60s Le

6 SINEAX V 60s Rely on us. Camille Bauer AG Aargauerstrasse CH-560 Wohlen / Switzerland Phone: Fax: info@camillebauer.com Subject to changes Issue 06.0 Data sheet V 60s Le

SINEAX V604s Programmable multifunctional transmitter

SINEAX V604s Programmable multifunctional transmitter SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:

More information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Description of functions Controller system VR660 / A200R

Description of functions Controller system VR660 / A200R Description of functions Controller system VR660 / A00R Local bus RS VR660/A00R e 56 76-0.07 Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen/Switzerland Phone + 56 68 Fax + 56 68 5 5 e-mail: info@camillebauer.com

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 536 Phase Angle or Power Factor Transducer SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave

More information

SINEAX I 552 Transducer for AC current

SINEAX I 552 Transducer for AC current SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load

More information

KINAX 2W2 Programmable Transmitter for Angular Position

KINAX 2W2 Programmable Transmitter for Angular Position Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

KINAX WT 717 Programmable Transmitter for Angular Position

KINAX WT 717 Programmable Transmitter for Angular Position Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

SINEAX VC 603, Programmable combined transmitter/alarm unit

SINEAX VC 603, Programmable combined transmitter/alarm unit for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Fig. 1) converts the input variable a DC current or voltage, or a signal

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX G 537 Transducer for Phase Angle Difference Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Operating instructions. SINEAX VC604s Programmable Safety Value Converter

Operating instructions. SINEAX VC604s Programmable Safety Value Converter Operating instructions SINEAX VC60s Programmable Safety Value Converter VC60s Be Version 0 09. Camille Bauer AG Aargauerstrasse CH-560 Wohlen/Switzerland Phone + 56 6 Fax + 56 6 info@camillebauer.com www.camillebauer.com

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

EURAX VC 603 Programmable combined transmitter/alarm unit

EURAX VC 603 Programmable combined transmitter/alarm unit EURX VC 603 for DC currents or voltages, temperature sensors, remote sensors or potentiometers 010 II (1) GD pplication The combined transmitter/alarm unit EURX VC 603 (Fig. 1) converts the input variable

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

RE92. CHECKMATE. Dual loop controller for industry purpose.

RE92. CHECKMATE. Dual loop controller for industry purpose. ! " # $ % & & ( ) * +. 0 1 2 3 4 5 8 9 6 : 7 ; * < + = >? @. A B C 0 D 1 E F G H 2 D I J 3? RE92. CHECKMATE. Dual loop controller for industry purpose. Simple and userfriendly service Safety and reliability

More information

EURAX UI 505, Combined Transducer for AC current and AC voltage

EURAX UI 505, Combined Transducer for AC current and AC voltage Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

Plug-in module SIRAX TI 807 Passive DC signal isolator

Plug-in module SIRAX TI 807 Passive DC signal isolator without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which

More information

itemp PA TMT184 Technical information

itemp PA TMT184 Technical information Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and

More information

Digital Indicator DS 96/48 PK

Digital Indicator DS 96/48 PK Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output kw Digital panel meter ½-digit DV, DT Without setpoints Analog status /0/04 - panelmeter_gb.doc page subject to alterations; errs including printer s errs Digital panel meter Direct voltage Direct current

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

DIGITAL PANEL METER N24 AND N25 METER SERIES

DIGITAL PANEL METER N24 AND N25 METER SERIES DIGITAL PANEL METER N24 AND N25 METER SERIES USER S MANUAL Contents 1. APPLICATION...5 2. METER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1 Fixing Way...7 4.2 External Connection Diagrams...8

More information

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 25 mm without plug-in terminal adjustment via factory default or directly

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status /0/04 panelmeter6x4_gb.doc page subject to alterations; errs including printer s errs 6x4 Digital panel meter Direct

More information

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly

More information

m/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication

m/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication P m/min Digital panel meter with 4½digit PV4, PT4, PF4, PW4 galvanically insulated free scalable setpoints/hysteresis optical setpoint indication analog galvanically insulated sens supply galvanically

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated P VA Digital panel meter with microprocess based technology digit PVE, PTE, PFE, PFL Galvanically insulated free scalable s/hysteresis Analogue galvanically insulated Min/max memy status //0 panelmeterx6analog_gb.doc

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

VariTrans P D1 TRMS

VariTrans P D1 TRMS Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status 06/03/0 panelmeter_gb.doc page subject to alterations; errs including printer s errs Digital panel meter Direct voltage

More information

5 years! Modular Housings. VariTrans P Warranty

5 years! Modular Housings. VariTrans P Warranty Modular Housings VariTrans P 27000 The Multimeter among the isolators. With 480 switchable calibrated ranges and broad-range power supply. The Task A wide range of measuring signals need to be galvanically

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

Signal converters Index

Signal converters Index Index Power supplies - Signal and data converters General information...1 Analog signal converters....3.26 Features and benefits...3 Application, approvals and marks...4 Overview...5 -.6 Ordering details...7

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven) Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000 High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.

More information