1 Magnetically operated level es Product group 740 Selection table Equipment for Magnetic evel Gauges type 7 Type Sheet: 1/1 Revision: 6 05/05 Table Mechanical Data for evel Gauge 7. Housing Ingr. prot. Temperature Material Dimensions E 6059 mbient ins.pipe Vibration tolerance Type 098/4 0/0./4/00/ /10 //6 10/140/0/160 lu Makrolon Pocan SS 0x0 8x5 45x50 65x50 65x65 80x8 95x165 IP 54 IP 65 IP (90) C *) C C C C 0/50 C * *) 0/400 C * *) 0/500 C * *) 0,5 g g g ) Table, ExClassification Ex protection Switch element Voltage Switch Current Rupturing capacity Switch cycles Electr. connect. Type Ex d Ex i Ex m Reed, SPST Rotate, SPDT Triac Prox. sw., DI 194 8, V= (DI 194) 0V~/0 V= 0V~/00 V= 50V~/00 V= 4 V~ bis 0 V~ 0,4 m/,5 m m= 1 ~/0,5 = ~ ~/ = 4 m~ bis,5 ~ <<1W 1W 0 V/0 W 0 V/40 W 0 V 550 V > 5 > 6 > 7 Silicon cable PVC cable Screw terminals Remarks to use without restrictions to use with precautions, if the is part of an intrinsically safe circuit, e. g. DI 194 (amur) *) Makrolon/luhousing **) without insulate/with insulate 1) no insulation between es and pipe possible ccessories: Transmitter feed circuit

2 8 Magnetic Power Product group 740 Universal bistable magnetically operated Semiconductor relay controlled by Reed Switch direction reversible strap retainers 1 Operating mode Power mounting strap PE DC Operating mode small signal 80 Makrolon housing RCnetw. ast ~ + C 55 height version MX Protective circuits for Reed es,details see TK Diode DC X??????? oad?=code not in use Type 0060 Sheet: 1/ Revision: Field of pplication Hysteresis ca. [mm]: Fitting position: Ingress protection: Manner of fastening: Measures/weight: 9/07 This is for signalling level limits with magnetic level gauges. The element Reed has a very low mass and so can sustain very high shock and vibration stress. It can be used for power ing and small signal ing, you only have to use the appropriate screw terminals. GaugeType on basic pipe on heating jacket 7.4/XX Operating mode Power (Solid state Triacrelay) Small signal (Reed) Cable gland downwards IP65 lu/makrolon with strap retainers (ccesories s. page ) Makr.: 8x80x55/0, kg lu: 75x80x57/0, kg *)Insulate between housing and pipe above 0 C in pipe Shock: Vibrations: Housing =lu M=Makrolon Makr. lu Makr. lu 6 max. temperature of pipe 0 C *) at amb.temp.85 C 400 C *) at amb.temp.55 C 0 C *) at amb.temp.10 C 500 C *) at amb.temp.70 C 0 5 max. temp. of housing 70 C 90 C 10 C 10 C 6 7 g g

3 Magnetic Power Product group 740 pplication hints Cable gland: Screw terminals: Type 0060 Sheet: / Revision: 9/07,5 mm Power (Solid state relay withtriac) Operating voltage nominal for 90 % power: Operating voltage limit: oad current nominal for 90 % power / 0 V~: current (0 V~): max. power limit P n max : max. power limit P : nmin 4 V~ to 0 V~ 50 V~ 4 m~ to,5 ~ 6 m~ 550 V s. Diagram below Switch configured as MI ed on, if float is below V P nmin 5 P nmin =F(U,P%) n 95% 90% P% 0 U n V Small signal (Reed) Operating voltage limit: Operating current limit: Rupturing capacity UxI : max 00 V= / 0 V~ 0,5 5W Switch configured as MX, pcboard and strap retainer reversed ed on, if float is above The is not suitable for the ex area also with the exclusive use as small signal. Circuit diagram R1 F1 PE for accessories TR1 DC ll fixing elements made of Ordering o. Mounting strap Strap retainers for 7.4/XX 178 Strap retainers for 7.0/ 1746 Strap retainers for 7.1/10/6/10/0. 175

4 Magnetically operated Ex m Product group 740 Bistable changeover with patented element Switch contacts magnetically operated Pipe clamp integrated Type 006 Sheet: 1/1 Revision: 4 08/04 Range of application This SPDT is for signalling level limits of magnetically operated liquid level gauges. It works with contact types which need not be protected by special means and so may be operated with higher loads. The can be used for ExZone and Ex Zone 1. M16x1, black Idendification plate blue brown Pipe clamp yellow/green area Hysteresis: 18 mm (with Type 7.0) luminium Fixing device for magnetic gauge type: : 7.0.0/4/XX.0 pipe clamp Æ4060 mm B: 7.// pipe clamp Æ6080 mm Temperature ambient: Temperature housing: Temperature in gauge pipe: *)Insulate between and gauge pipe above 0 C in pipe Exprotection: mbient temperature for temperature class: Function MX (Float above): MI (Float below): Switch over bistable: Switch voltage: Switch current: max. power limit: Contact material: Transit time: Connection: Ingress protection acc. to E 6059: Certificates 45 to + C 65 to + C up to 400 C *) 5 > EEx m II T4, T5, T6 T4: 45 C to + C T5: 45 C to +95 C T6: 45 C to +80 C black blue closed brown blue closed SPDT 00 V =/50 V~ =/~ 40 W/0 V gcd / u5m <50ms m silicone cable (resistantly approximately nick) 4 x 0,75 mm IP 67 ECTypeExamination Certificate: ZEM 0 TEX X B XX X 7.0.0/4/XX.0 7.// cable length in m for magnetic gauge type

5 75 Magnetically operated SPDT Productgroup 740 Bistable changeover with patented element Switch contacts magnetically operated Type 0064 Execution with heat guard plate Measures in mm Connection Diagram diagram black Mounting strap Strap retainers R s Cable Cable connection blue brown yellow/green 57 heigth Switch point R s Type Screw terminals connection X X X X X X Contact material Housing material Resistor circuit ormal Gold luminum without amur 1k/k wire interr. k/k C G O D 0 H K 5 H I inverse normal screw terminals m cable 5 m cable Harting plug up to +50 C C Sheet: 1/1 Revision: 9 0/05 Range of application This SPDT is for signalling level limits of magnetically operated liquid level gauges. It works with contact types which need not be protected by special means and so may be operated with higher loads. ExZone in general and Ex Zone 1 with intrinsically safe circuits is allowed, because only passive elements are built into a swagedtight housing. Hysteresis: 18 mm (with Type 7.0) luminium Fixing device for magnetic gauge type (accessory): 7.0.0/4/098/ XX.0 strap retainers Æ4060 mm 7.// strap retainers Æ6080 mm Temperature medium [ C] Function MX (Float oabove): MI (Float below): > 5 black (1) blue () closed brown () blue () closed Switch over bistable: SPDT Switch voltage: 00 V =/50 V~ Switch current: =/~ max. power limit: 40 W/0 V Contact material: gcd / u5m Transit time: <50ms Connection: m or 5 m cable, 4 x 0,75 mm or screw terminals x,5 mm Cable gland: Ingress protection acc. to E 6059: IP67 Optional resistors Rp, Rs for wire interruption and short circuit control or as amur circuit. Magnetic field direction Electrical connection Temp. in the pipe mbient temperature [ C] DeratingDiagram with heat guard plate with heat guard plate without heat guard plate ttention! Do not isolate the together with the pipe

6 75 Magnetically controlled imit Switch Product group 740 Bistable magnetic Reed contact Switch direction reversible strap retainers mounting strap 1 operating mode without resistors 1 R s short and open circuit monitoring, amur circuit X X 57 height W 80 protective circuits for Reed es, details see TK ~ RCnetw. C Picture: Type IP 67 oad + sdelivered condition ex factory inverted direction diode DC without with amur circuit with short/open circuit monitoring oad Field of pplication Type 0065 Sheet: 1/1 Revision: 8 1/07 This is for signalling level limits with magnetic level gauges. The element Reed has a very low mass and so can sustain very high shock and vibration stress. By using only passive elements (Reed contact, resistors) the can operate in hazardous area zone and as part of an intrinsic safe circuit also in zone 1. Hysteresis ca. [mm]: Gauge Type on basic pipe on heating jacket 7.4/XX Fitting position: Manner of fastening: Ingress protection: Measures/weight: housing lu Shock: Vibration: 6 max. temperature of pipe 500 C *) at amb. temp.70 C 0 5 cable gland downwards with strap retainers IP67 lu lu: 75x80x57/0, kg *) Insulate between housing and pipe above 60 C in pipe Switch voltage: Switch current: max. power limit: Connection: ccessories Resistor circuit temperature of housing C 6 > g g 00 V =/0 V~ 0,5 5W screw terminals, Strap retainers for 7.4/XX: Strap retainers for 7.0/: Strap retainers for 7.110/6/0.: subject to alterations

7 Magnetically controlled imit Switch Bistable magnetic Reed contact Product group Type sw() bn() bl(1) strap retainer for pipeæ 460mm Æ 0 sw() bn() bl(1) point strap retainer k k External resistors for operation in cicuit acc. to DI 194 strap retainer 1k Field of pplication Temperature housing: Contact: Function: Switch type: Shock: Vibration: Sheet: 1/1 Revision: 8/0 This is for signalling level limits with magnetic level gauges type and 7.4. The element Reed has a very low mass and so can sustain very high shock and vibration stress. By using only passive elements (Reed contact, resistors) the can operate in hazardous area zone and as part of an intrinsic safe circuit also in zone 1. Hysteresis ca. [mm]: Fitting position: Manner of fastening: Ingress protection: Measures/weight: Switch voltage: Switch current: max. power limit: Connection: 6mm cable gland downwards with integrated strap retainer IP67 SS 1x0/0,1 kg C Reed SPDT bistable 6 > g g 0V~/0V= 1~/0,5= 0V/0W 1,5 m silicon cable, 4 x 0,75 mm External resistor for operation with SPS sw() R bn() bl(1) protective circuits for Reed es R oad Diode oad ~ C + C circuit DC circuit subject to alterations

8 75 Magnetic imit Product group 740 Bistable magnetically operated Proximity acc. to MUR Switch direction reversible Switching status remains in the currentless condition Example: Z MX Strap retainers Mounting strap IP 65 point + DI E Z BK WH ZS/SS B BU Z Exec. MI Cylindricproximity S Exec. MI Slitproximity 57 height Type 000 Sheet: 1/ Revision: Fastening: Fitting position: Ingress protection: Measures/Weights: 1/08 Field of pplication This is for signalling level limits with magnetic level gauges. ll controllers in accordance with DI 507 (MUR) may be used for operation. Use in Ex Zone 1 and is allowed only when connected to intrinsically safe circuits. lso redundant and fail safe operation is possible. Switching rate: Hz Hysteresis [mm]: Gauge Type ZS SS Z 7.0//6/1/10/ / / /10./ Temperature medium [ C] Interface: Wire cross section: with strap retainers (cc., s. page ) Cable gland downwards IP67 luminium 75x80x57/0,4 kg to DI E 507,5 mm Cable gland: blue Switch module Type, principle Redundant safety Z ZS SS with heat prev. plate without heat prev. plate with insulation plate mbient Temperature [ C] Cylindric, Hall Cylindric, inductive Slit, inductive DeratingDiagram ttention! Don't insulate with pipe no yes yes X X X X Safety direction MI MX H Z S S I Standard Redundant Cylindric Slit normal inverted Magnetic field float Proximity Form

9 Magnetic limit Product group 740 pplication hints Type 000 Sheet: / Revision: 9 1/08 MX MI Power supply (DI E 507): Wire resistance: Switch module Type Z Exi Data: Parameter Ui Ii Pi i Ci EEx ib IIC T6/T5/T4 18 V 86 m 95 mw 1mH 0 nf 8, V= (Ri ca 1k W) < 0R MX for Hlevel The magnet damps the proximity when the float is higher (failsafe). Power supply and signal conversion acc. to MUR Example for discrete circuit DI E 507 1k 60R MI for level The magnet damps the proximity when the float is lower (failsafe). + 8, V Output current: current: Remaining ripple: Switch module Type ZS/SS ExData: U: i i ZS/SS: Ci ZS/SS: Temperature classes ZS + SS: Pi [mw] Ii [m] T6 [ C] T5 [ C] T4 [ C] current: current: < 0,4 m >,50 m < 0,0 m II G EEx ia IIC T6/T5/T4 16 V 0/0 mh 50/0 nf m ³ m Operation with an intrinsically safe controller DI E 507 ccessories + fixing elements intrinsic safe [EEx ia] IIB od. C [EEx ib] IIB od. C 740.6X Strap retainers for 7.4/XX 178 Strap retainers for 7.0/ 1746 Strap retainers for 7.1/10/6/10/ Certificates Switch module Type Z ECTypeExamination Certificate: ZEM 0 TEX 008 Switch module Type ZS/SS ECTypeExamination Certificate: PTB 00 TEX 049 X May be connected to intrinsic safe circuits and may be operated in zone 1 and zone.

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

Page Type Resolution (mm) min. max. Output

Page Type Resolution (mm) min. max. Output Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11,

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

KINAX WT 707 Transmitter for angular position

KINAX WT 707 Transmitter for angular position Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

Speed and Positioning Sensor GEL 2478

Speed and Positioning Sensor GEL 2478 Speed and Positioning Sensor GEL 78 lso suitable for use explosion-hazardous areas Technical information Version 0.09 Key features Contactless measurement of linear or rotational movements One or two channels

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable Siemens G 008 SIMTIC PXI inductive proximity switches Introduction Inductive proximity switches rugged, accurate and reliable PXI series The inductive proximity switches are organized in different product

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Plug-in module SIRAX TI 807 Passive DC signal isolator

Plug-in module SIRAX TI 807 Passive DC signal isolator without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 13.0023X Issue No.: 0 Description: The Measuring Gauge of type series SMALL * / / / / / / / / / / * / * is an intrinsically safe supplied apparatus providing different electronic

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Electrical Alarm Contacts

Electrical Alarm Contacts Accessories Electrical Alarm Contacts Model 82, Magnetic Snap-Action Contact Model 83, Inductive Alarm Contact Model 830 E, Electronic Contact WIKA Data Sheet AC 08.0 Applications Control and regulation

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter Description RotaMass 3 Series Coriolis Mass Flow Meter; - Integral Transmitter, Model RCCx; - Remote Converter, Model RCCF31; - Remote Converter, Model RCCR31; - Remote Detector Model RCCS3xxxx The Coriolis

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Operating Instructions

Operating Instructions Operating Instructions FLUDEX-EOC system A. Friedr. Flender AG 46393 Bocholt Tel. 02871/92-0 Telefax 02871/92-2596 www.flender.com Contents 1. Application 3 2. Operation 3 3. Fitting 4 3.1 Fitting transmitter

More information

Attachment to Certificate IECEx PTB X

Attachment to Certificate IECEx PTB X Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Submersible pressure sensor For superior applications Model LF-1

Submersible pressure sensor For superior applications Model LF-1 Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring

More information

Technical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m

Technical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m B 6,5 3,5 4 44 33,5 13 4 00 Flat design on-contacting principle 1 Reed contact ctuating distance up to 60 mm depending on actuating magnet and version ctuating surface marked by protrusion Pre-wired cable

More information

2 or 4 pole changeover contact Plug-in/Faston 187

2 or 4 pole changeover contact Plug-in/Faston 187 56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL TRANSMITTERS O U R P R O F E S S I O N NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Electrical Alarm Contacts

Electrical Alarm Contacts Accessories Electrical Alarm Contacts T Model 821, Magnetic Snap-Action Contacts T Model 831, Inductive Alarm Sensors T Model 830 E, Electronic Contacts WIKA Data Sheet AC 08.01 Applications T Control

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

CombiTemp TCR6 Standard RTD temperature sensor

CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water

More information

Temperature Transmitters TMT 136, TMT 137

Temperature Transmitters TMT 136, TMT 137 Technical Information TI 066R/09/en Part No. 51000855 Temperature Transmitters TMT 136, TMT 137 For Pt100 Resistance Thermometers 2-wire head transmitter Standard- and instrinsically safe versions Head

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information