Plug-in module SIRAX TI 807 Passive DC signal isolator

Size: px
Start display at page:

Download "Plug-in module SIRAX TI 807 Passive DC signal isolator"

Transcription

1 without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which depending on version is then converted to a current or voltage signal (0 20 m or 0 10 V). It operates passively and does not require a separate power supply, but derives the little auxiliary energy it needs from the DC signal. The series of isolators also includes intrinsically safe explosion-proof versions with either an intrinsically safe input signal [x ib] IIC or intrinsically safe output signal [x ia] IIC. They are thus suitable for use in connection with intrinsically safe equipment installed in the hazardous area. The SIRX TI 807 is supplied with two or three channels. The signal isolator fulfils all the important requirements and regulations concerning electromagnetic compatibility MC and Safe isolation (IC 1010 resp. N ). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO Production Q is also certified according to guideline 94/9/. Fig. 1. Plug-in module SIRX TI 807 for plugging onto backplane BP 902. Features / Benefits Signal isolator plugs onto backplane (mechanically latched by fasteners), all electrical connections made to the backplane and not to the SIRX TI 807 / Thus no wiring when replacing devices lectrically insulated analogue DC signals 0 20 m / Prevents the transfer of interference voltages and currents. Solves grounding problems in meshed signal networks Highly accurate / Performs its isolating function with negligible transmission error No power supply required / Saves wiring costs and is easy to install in existing plants vailable in type of protection Intrinsic safety [x ib] IIC or [x ia] IIC (see Table 2 Data on explosion protection ) Layout and mode of operation Description of a function unit. The DC signal isolator comprises a DC chopper Z, an isolating stage T, a rectifier and an oscillator O. The chopper converts the DC input signal = 0 20 m to an C signal which is transformed with electrical insulation, rectified, smoothed and appears at the output as a DC current signal = 0 20 m (Fig. 2, left). Versions with a DC output voltage signal = 0 10 V have a resistive burden of (Fig. 2, right). The chopper is controlled by the oscillator which obtains its power from the DC signal. Z O T U V Fig. 2. Block diagram for a function unit. Camille Bauer Data sheet TI Le

2 Technical data Input signal DC current signal I Max. permissible current 0 20 m 50 m Voltage limiter Non-x version 27 V ± 5% (with zener diode) x version 18 V, ± 5% Output signal (DC current or DC voltage) DC current signal I Voltage drop U V 0 20 m < 2.8 V with standard (non-x) version < 4.7 V < 6.3 V Max. burden 1000 Ω with standard (non-x) version Limit Residual ripple Time constant Response time 1 acc. to IC 770 DC voltage signal U Voltage drop U V pprox. 40 m < 20 mv ss pprox. 3 ms pprox. 15 ms 0 10 V < 2.8 V with standard (non-x) version < 4.7 V < 6.3 V Internal resistance Limit < 26 V with standard (non-x) version < 16 V < 16 V Response time 1 acc. to IC 770 ccuracy data pprox. 15 ms rror limits < ± 0.1% (Reference value 20 m of output signal, typical linearity error included) < ± 0.2% (Reference value 10 V of output signal, typical linearity error included) Reference conditions DC current signal I mbient temperature Output burden dditional error Burden influence Temperature coefficient Installation data Housing Material of housing Designation SIRX TI 807 Mounting position lectrical connections Coding Weight 0 20 m 23 C ± 1 K 250 Ω (at DC current output signal) 5 MΩ (at DC voltage output signal) < 0.05% / 100 Ω (at DC current output signal) < 50 ppm/k Signal isolator in housing B17 for plugging onto backplane BP 902. Refer to Section Dimensional drawings for dimensions Lexan 940 (polycarbonate). Flammability Class V-0 acc. to UL 94, self-extinguishing, nondripping, free of halogen ny 96-pin connector acc. to DIN , pattern C Layout see Section lectrical connections Signal isolator supplied already coded. The rack is coded by the user by fitting the coding inserts supplied pprox kg Residual ripple Time constant < 20 mv ss pprox. 3 ms 1 This is the time which transpires before the output signal reaches the error limit of 1% for a step change of the input signal from 0 90%. 2 Data sheet TI Le Camille Bauer

3 Regulations lectromagnetic compatibility The standards DIN N and DIN N are observed Intrinsically safe cc. to DIN N lectrical design cc. to IC 1010 resp. N Protection (acc. to IC 529 resp. N ) Housing IP 40 Terminals IP 00 Contamination level 2 Overvoltage category acc. to IC 664 II Test voltage 2.3 kv, 50 Hz, 1 min. Inputs versus outputs Inputs versus inputs Outputs versus outputs Surge voltage 4.25 kv, 1.2/50 µs Inputs versus outputs Inputs versus inputs Outputs versus outputs mbient conditions Commissioning temperature 10 to 40 C Operating temperature 25 to 40 C, x 20 to 40 C Storage temperature 40 to 70 C nnual mean relative humidity 75% ltitude 2000 m max. Indoor use statement! Table 1 Order informations DSCRIPTION MRKIN 1. Mechanical design Housing B17 (for plugging onto backplane BP 902, see data sheets) 2. Version Standard (non-x) 1 [x ib] IIC, input signals intrinsically safe 2 [x ia] IIC, output signals intrinsically safe 6 3. Number of isolation channels 2 channels 2 3 channels 3 4. Output signals (1 and 2 or 1, 2 and 3) 0 20 m V, 2 channels V, 3 channels 3 Possible special versions, e.g. increased climatic rating on inquiry. Table 2 Data on explosion protection II (2) resp. II (1) Order Code Type of protection [x ib] IIC [x ia] IIC Input Output Type examination certificate L i = 24 µh C i = 0 for connection to certified intrinsically safe circuit with following maximum values U i = 30 V I i = 150 m U m = 253 V C resp. 125 V DC U m = 253 V C resp. 125 V DC U o = 15,75 V I o = 100 m P o = 400 mw linear characteristic IIC IIB L o 4 mh 15 mh C o 478 nf 2.88 µf PTB 97 TX 2102 Mounting location outside the hazardous area Camille Bauer Data sheet TI Le

4 lectrical connections SIRX TI 807 Front Fastener SIRX TI and SIRX TI Rear c b a SIRX TI Rear c b a B C B C Camille Bauer CH-5610 Wohlen Switzerland D 14 D 14 F F H 20 H 20 OSSN MTRWTT CMILL BUR SIRX TI 807 I K L M I K L M , 2, 3 = Input signals 1, 2, 3 = Output signals Plug-in module SIRX TI 807 c27 a26 a1 c2 c29 a28 a3 c4 c31 a30 a5 c6 Backplane Connecting allocation see Operating Instructions of backplanes , 2, 3 = Input signals 1, 2, 3 = Output signals Fig. 3. SIRX TI , standard (non-x) version and SIRX TI , x version, (output signals intrinsically safe). 4 Data sheet TI Le Camille Bauer

5 Plug-in module SIRX TI 807 a1 c2 c27 a26 a3 c4 c29 a28 a5 c6 c31 a30 Backplane Connecting allocation see Operating Instructions of backplanes , 2, 3 = Input signals 1, 2, 3 = Output signals Fig. 4. SIRX TI , x version, (input signals intrinsically safe). Table 3 ccessories and spare parts Description Coding comb with 12 sets of codes (for coding the backplane BP 902) Order No Operating Instructions TI B d-f-e Standard accessories 1 Operating Instructions for SIRX TI 807, in three languages erman, French, nglish 1 Coding comb with 12 sets of codes 1 Type examination certificate (only for instruments in type of protection Intrinsically safe ) Dimensional drawing 150, ,3 123,5 113,5 135, ,5 Rely on us. Fig. 5. SIRX TI 807 in housing B17. Camille Bauer argauerstrasse 7 CH-5610 Wohlen / Switzerland Phone Fax info@camillebauer.com Subject to change without notice dition Data sheet TI Le

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input

More information

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX G 537 Transducer for Phase Angle Difference Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

KINAX WT 707 Transmitter for angular position

KINAX WT 707 Transmitter for angular position Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 536 Phase Angle or Power Factor Transducer SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

SINEAX I 552 Transducer for AC current

SINEAX I 552 Transducer for AC current SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

KINAX 2W2 Programmable Transmitter for Angular Position

KINAX 2W2 Programmable Transmitter for Angular Position Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has

More information

KINAX WT 717 Programmable Transmitter for Angular Position

KINAX WT 717 Programmable Transmitter for Angular Position Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

EURAX UI 505, Combined Transducer for AC current and AC voltage

EURAX UI 505, Combined Transducer for AC current and AC voltage Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

KINAX 3W2 Transmitter for angular position

KINAX 3W2 Transmitter for angular position KINX 3W2 For installation KINX 3W2 is a compact transmitter for angular position for installation in devices and apparatus. Due to its unique capacitive measuring principle, it acquires the angular position

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

EMBSIN 281 G Power factor transducer

EMBSIN 281 G Power factor transducer EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits for s or voltages, temperature sensors, remote sensors or potentiometers pplication The universal transmitter RISH Ducer V 604 (Figures 1 and 2) convert the input variable a or voltage, or a signal from

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

EURAX VC 603 Programmable combined transmitter/alarm unit

EURAX VC 603 Programmable combined transmitter/alarm unit EURX VC 603 for DC currents or voltages, temperature sensors, remote sensors or potentiometers 010 II (1) GD pplication The combined transmitter/alarm unit EURX VC 603 (Fig. 1) converts the input variable

More information

SINEAX V604s Programmable multifunctional transmitter

SINEAX V604s Programmable multifunctional transmitter SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5. GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Theta Hz. Technical Data Sheet. Special Features

Theta Hz. Technical Data Sheet. Special Features Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

OPTITEMP TT 10 C/R Technical Datasheet

OPTITEMP TT 10 C/R Technical Datasheet OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version Electrical temperature measurement Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version WIKA data sheet TE 32.04 Applications Process

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Level Measurement silometer FMX 570

Level Measurement silometer FMX 570 Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Analog signal converters CC-E I/I

Analog signal converters CC-E I/I 2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage

More information

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

SUBJECT TO CHANGE WITHOUT NOTICE

SUBJECT TO CHANGE WITHOUT NOTICE TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

Level Limit Switch nivotester FTL 370, FTL 372

Level Limit Switch nivotester FTL 370, FTL 372 Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information