SERVICE 2565HK AND 2565HKM TELEPHONE SETS
|
|
- Sydney Green
- 5 years ago
- Views:
Transcription
1 BELL SYSTEM PRACTCES AT&TCo Standard ssue 6, October 1975 SERVCE 565HK AND 565HKM TELEPHONE SETS 1. GENERAL 1.01 This section provides connection information for the 565HK and 565HKM telephone sets. 1.0 Reissued to add information on the 565HKM (modular) telephone sets, Fig. 1, sheet.. CONNECTONS.01 These sets are factory-wired for use with 1A1 or 1A key telephone systems (KTS), -type or 4A speakerphone, and individual or common line ringer. They can be used with 1A KTS by modifying as shown in Fig. and..0 Mounting cord leads are provided for illuminating the hold key position but lamp is not furnished with set..0 These sets are factory-equipped with a KS-0419L1 (10 volt AC only) buzzer..04 The H1B ringer leads are factory-wired to terminals RR and RT. When power failure feature is provided in the KTS, common audible signal must be wired with capacitor in series..06 When a 565-type set not furnishing speakerphone feature is multipled with sets furnishing speakerphone feature, certain control leads must be disconnected, insulated and stored (Note, Fig. 1) to avoid interference with working circuits..07 Exclusion can be added to these sets by installing a D Kit of Parts which must be ordered separately. Connect as shown in Table A. Exclusion key can also be used to cut off a ringer or buzzer in set..08 Use an A0B connector cable when speakerphone and exclusion features are not provided..09 When polarity gurad is required in these sets, install t or P-90D05 guard assembly. Connect as shown in Table C..10 Additional terminating points can be gained when required for auxiliary services such as buzzers, etc. by installing t or P-5E96 terminal strip assembly..11 nstallation of exclusion switch, polarity guard, and auxiliary terminal strip is covered in Section f speakerphone (-type) control unit is located near telephone set, the necessary mounting cord conductors can be extended to the control unit using a 149-type adapter or 66E-type connecting block. f control unit is located at key equipment, extend leads through A5B connector cable or inside wiring cable. Speakerphone connections for the 565-type telephone sets are shown in Division All convertible key positions are supplied as pickup keys. To convert from pickup (locking) to signaling (nonlocking), remove the t or P-1A89 screw detail from key position involved. Make necessary wiring changes as shown in Table B..1 Lamp in hold position can be furnished but must be separately ordered and installed. NOTCE Not for use or disclosure outside the Bell System except under written agreement Printed in ll.s.a. Page 1 SSP i06_ l.jpg Scanned by Frank Harrell, {Cowboy Frank) Castle Rock, Colorado Feb 0,01 :56:4
2 R () T ) R 11 T 11 A, A OR R 1 GA KTS LNE T 1) CONN$ R 151 T (51 ["' R SPE AK ERPHONE T NOTE9) Tl L ) LG ) L () LG () L () A, A OR LG () 6A KTS LNE L 141 CONNS LG 141 [ L 151 LG (51 BZ BUZZER S BZ LK SPEAKERPHONE (NOTE 9} Al-B A-H S () A-H 1 1 A -A S () KTS A A-H-S () CONNS A-H-S(4) S (51 A-H-S (5) (NOTE 9) AG SPEAKERPHONE SL R (4) T (4} S (4) [R-R RNGER CRCUT S-S TPA NOTE ) CLP NO S PART OF 0N MTG CORO BL-W (W-SL) SR-W),.,_ R T,-,. R 66A KEY PU e d 49 -V--SR W c t (0- SK) G-W '( lv V- BL) W- BL SL-V W-SR),.,_ T EXCN 9 TCH lo-r R SL -W - (NOTE 1 R -0),.,_ T TO TABLE A W-01 (S-R,.,_ 4R 10 (V- OJ + R-S,.,_ 4T (O-Wl G-SK n. 5R SK-G) ;::: 5T 10-V) G + B Lt G-V SR-V) 7 4,.., V - Gl G t (OJ 48 (G W Ll NOTE PART OF CLP NO. DN 8 4 SL-V SL-R L 0 ER 1 ( [" T 41 V- BL 0 1 EXCLUDED 46 ( ET (BR-R) L STATON B 44 (0-V) 0ES ( NOTE 9) A- H 4 V- OJ 0 47 ( EH (0-SK L4 1 Y-SL) 41 ( 0 (0-Y) 7 17 ( 0 S-SK - L ( 0 4 SL-Y) 16 * G-Y - 6 BL S BR-Y) KS- 0419L 0sG,.,. 19 ( Y-G AC 5(SLJ BUZZER 4 S V) Lit ls 5 PU Y-sR J "'"'[ SG lo -W),-,. S Y b- W-01 fa S-W H n. M N * W-S 0 t BR c H 10- ( G-R) (S-R SK) * R-G H SR (BL-BK) * t HA RNGER SK- BL X 6,-,. 4H RR 6{l R S-R SR-SK) * i {"" (SK- SR 5H SR-SK) Kt Y-S RT (BK) OOOfi ls V-S 5 O _ci_y_-s_r_cl { 0 1 i NOTES 4,5, AND 6) 4 - HS RNGER S-Y } At S-Y RR S)STRAP / _ Y_-_s_J--- _ _j L j', 45 '<" Kt "' Y H 4 Y-01 r- _ Fig. 1-*565HK or 565HKM Telephone Set, Factory-Wired for 1A1 or 1A KTS and Speakerphone, Connections (Sheet 1 of ). Page SSP i06_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :56:54
3 SS 6, SECTON S GA HANDSET GNt V) (0) t.. l y z X w v e i L _j (R) BL) R-G) W-BL) 1 Tt (R) 'V Bt BK) XJ Rt T (BK) (R) lst RR Ls+;, 45K NETWORK TRMTR RCVR l ru Fig HK or 565HKM Telephone Set, Factory-Wired for la or 1A KTS and Speakerphone Connections (Sheet of ). Page SSP i06_197S-10-0.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :57:
4 GSA RR BKl 10) y z L j 1 45K NETWORK NOTES:. 66E-TYPE CONNECTNG BLOCK SHO\oti. MOUNTNG CORD MAY BE PLUGGED DRECTLY NTO CONNECTOR CABLE. COLORS AND PN NUMBERS FOR CONNECTOR CABLE ARE SAME AS MOUNTNG CORD.. F EXCLUSON FEATURE S ADDEO, CONNECT SWTCH S PER TABLE A.. DSCONNECT Tl, Rl, T, R, AG, AND LK S WHEN SETS NOT EQUPPED WTH SPEAKERPHONE ARE MULl PL EO. 01 SCONNECT AT THE SET. 4. FOR BRDGED RNGER ON ANY LNE USNG HA RNGER, CONNECT (R ) RNGER TO RNG AND (BK) RNGER TO TP OF LNE NVOLVED. FOR BRDGED RNGER ON ANY LNE USNG HB RNGER, REMOVE ( S ) STRAP FROM RR (KEY TERMNAL BOARD ) AND CONNECT TO RNG AND ( BK ) RNGER TO TP OF LNE NVOLVED. 5. F CAPACTOR S NOT REQURED N RNGER CRCUT, MOVE (S ) RNGER TO A OF NETiol:lRK FOR HA RNGER AND (R ) RNGER TO A OF NETiol:lRK FOR HB RNGER. 6. TO SLENCE RNGER PERMANENTLY NSULATE AND STORE (BK ) AND (R ) RNGER S. 7. LNE SWTCH SEQUENCE - be MAKES FRST, be MAKES BEFORE ab BREAKS, de MA<ES SECOND, fg BREAKS LAST 8. F HOLD POSTON S REQURED, USE SPARE PAR AND SPARE TERMNA OR CONNECTORS. 9. USE AN A0B CONNECTOR CABLE WHEN SPEAKERPHONE AND EXCLUSON FEATURES ARE NOT PROV OED. PU - PCKUP KEY H - HOLD KEY - Ll NE SWTCH * - NSULATED AND STORED - NETWORK TERMNAL - UNOESGNATEO TERMNA ARE ON K(Y TERMNAL BOARD. Fig HK or 565HKM Telephone Set, Factory-Wired for la 1 or 1A KTS and Speakerphone Connections (Sheet of ). Page 4 SSP i06_197S jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :57:4
5 SS 6, A OR A KTS \ TH [: 44 A (O-W) S ( Y) 'V LK+ (S-V) Lit (S) BL (Y-BR) AG (V-S) b +. (BR) (0-SK) F H M MODFCATON A-A KTS from TO (BR) N (V-S) N KS-1574L TO N DODE la KTS WTH ( LK* (S-V) Lit (S) SG (BR-Y) SG BL (Y-BR) (BR) AG+ (V-S) Rl+ (G-V) N ct d)(' 0 )(w M (0-BK) MODFCATON la KTS from TO B SG (BR) N (V-S) N M 9 (0-BK) N M 9 N (G-V) 9 N MOOFCAT10N HOL D AND A-A KTS A (0-\1) 18 (BR) N A OR A KTS WTH HOLD \ TH/W THOUT 5 (BR) BL (Y-BR) 44 LK + (S-V) L e lt (s ) b 0 AG+ (V-S) SP (Y-BL) 16 WTH (V-Sl N LAM P KS-1574L DODE TO OPTON (Yl M (0-BK) N MW CORD (BRl N WTHOUT ( V-S) N (Yl (0-BK) N OPTON MW CORD NOTE: t NET WORK TERMNA. UNDESGNAT ED REMOVE (0-Y) from KEY TERMNAL. TERMNA ARE ON KEY TERMNAL BOARD NSULATE AND STORE. + - TYPE SPEAKERPHONE - LNE SW TCH H- HOL D KEY Fig. -0ptional Features with -Type Speakerphone Page 5 BSP i06_ QS.jpg Scanned by Frank Harrell. (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :58:07
6 DES G 66-TYPE CONN BLK (SEE ol 7 N 6 PE CORD (0 W _ LK D8S (Q-\1) 08-TYPE PK SET j :: 00N :: l '-+ii-:-:-:-: A ADAPTER (0-\1) TELEPHONE SET Lit (S) l, }..,f'-- \''C >r-- -':'-':' :t s %-- ( Y -B R ) - % : ----+* J!JK\L -4 STATON MODFCATON A-A KTS (BR) (W-0) KS-1 S74L Dl OOE TO N NOTE 66-TYPE CONNECTNG BLOCK SHO\N, MTG CORD MAY BE PLUGGED DRECTLY NTO CONNECTOR CABLE, COLORS AND PN NUMBERS FOR CONNECTOR CABLE ARE SAME AS.!lliil:: (0-BK) L _:c_ H - (S-Y) Ll+ * (Y-S) * OESG 680-TYPE TRMTR D8S A. A-A KTS \/RED FOR \lith M6C CORD TERMN ATED N TEL SET 108-TYPE PK SET D0N A ADAPTER M6C CORD 66-TYPE CONN BLK (SEE DN "'''''' TELEPHONE MT: ::D S S Lit :_=====+B===:i#=;======++=====::: +::_==f+==;=5;+--(0-)--' ]?@1B(Y (v-s) :l STATON MODFCATON A-A KTS (BR) N (Y-S) N KS-1574L DODE TO N * NSULATE AND STORE t NETWORK TERMNALŪNDESGNATED ARE ON KEY TERMNAL BOARD 161A ADAPTERS REQURED TO CONNECT M6C CORD AT 66-TYPE CONN BLK Ll NE SWTCH H HOLD KEY 8. A-A KTS \/RED FOR \lith M6C CORD TERMNATED AT 66-TYPE CONN BLK Fig. --0ptional Features with 4A Speakerphone (Sheet 1 of ) Page 6 BSP i06_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :58:7
7 SS 6, DES G 66 TYPE CONN BL K (SEE NOT El 0N 680-TYPE TRMTR 08S OB TYPE D0N A M6C PK SET ADAPTER CORD TELEPHONE SET 8 7 (BR Y). (Y BR) LK (O W) (O W) 1nc A (W-BR (W-BR).i AG (W-0) (W O) Rl (BL W) (BL W) :;,.t ls '<J '-=! N Y) (BR) (Gl bf - STATON MODFCATON la KTS 18 SG BR N NOTE, w-o N 66 TYPE CONNECTNG BLOCK SHOWN. MTG s-v Lit.. CORD MAY BE PLUGGED DRECTLY NTO v-s N * CONNECTOR CABLE. COLORS AND PN (G V) 9 * NUMBERS FOR CONNECTOR CABLE ARE SAME (BL W) 9 N AS. 9 N y M 9 0 5K N M (W-BR) B SG A. la KTS WRED FOR WTH M6C CORD TERMNATED N TEL SET H r- d L s e ( Ct (0-BK) M DES G G SG 680-TYPE TRMTR LK 08S : (o-w) 108-TYPE PK SET ; 1, A 0DN (W-BR) A M6C 66-T YPE ADAPTER CORD BLK (o-w) (:: ;.4 ;)8, 0N TELEPHONE SET BL AG (W-0) (w-o) R 46 STATON MODFCATON la KTS y B SG BR N (V-S) N s-v) 9 N 9 N y M 9 O BK N M (O-Wl B SG * NSULATE AND STORE t NETWORK TERMNAL-UNOES GNATEO ARE ON KEY TERMNAL BOA RD * 161A ADAPTERS REQURED TO CONNECT M6C CORD AT 66-TYPE C ONN BLK LNE SWTCH H HOLD KEY 8. la KTS WRED FOR WTH M6C CORD TERMNATED AT 66 TYPE CONN BLK ct H H>(-'-(0=-...:B::;Kc:_l-0 M Fig. -0ptional Features with 4A Speakerphone (Sheet of ) Page 7 BSP S0-S4-405 i06_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0, 01 :58:55
8 . ". 66-TYPE W: DSON?* 680-TYPE TYPE flli D0N W. A fi OESG CONN BLK. MTG COOO q TRNTR. tottg CORD PK SET MTG CoRD AOAP TER i A. 'Jill A MJ 00 W BR Bl ) 44 ;!? (Y-BR) ". NOTE t ) till (O- w l LK <":;"" w-o.. 1 LJ.. WTH {!)OPTON WTHOUT OPTON WTH OR WTHOUT [ h1 1 -@ ' AG [\11 (w-o) %1 1:1 il M6C CO!O o-w... 11;1 M $ 1#4& <4 w -Oli-W - 7 tt fj M TELEPHONE SET Lit 16 Yl G) ) ( lk:j :''!'.! ( Y ) (NOTE ) {MW CORD "' j STATON HOLD A A KTS from TO H BR w-o (0-BK} KS-1574L NOTE.S: DODE TO. 66-TYP. CONNECTNG BLOCK SHOWN. MTG O BK CORD MAY BE PLUGGED 01 RECTL Y NTO y CONNECTOR CABLE. COLORS AND PN MW CORD NUMBERS for CONNECTOR CABLE ARE SAME (BR AS. w-o. REMOVE (O Y) from KEY TERM. O BK NSULATE AND STORE. MJW CORD (S-V) (v-s) Ll+ DESG A BL SP A A A KTS W REO for AND HOLD WTH M6C CORD TERMNATED N TEL SET 680-TYPE oas 108-TYPE TRMTR PK SET, WTH!Yi OPTON WTHOUT OPTON ::;. (1 9 AG STATON HOLD A A KTS from TO BR N v-s N ' KS-1574L TO DODE 0-BK N " MW CORD BR N v-s N 0-BK N y M MW CORD 00N A M6C 66-T YPE CO!O ADAPTER CORD t CONN BL K (O W) {NOT E 10-Wl 5 5o' (w-o) 47 W-Ol -, * NSULATE AND STORE t NETWORK TERMNAL-UNDESGNATEO TE RMJNA ARE ON KEY TERMNAL BOARD f 161A ADAPTERS REQURED TO CONNEC T M6C COOD AT 66-TYPE CONN BLK LNE SWTCH H HOLD KEY ; N CORD (S-V) to-w {Y-BR) V-51 (Y BLl TELEPHONE SET Lll <Y( 16 (Yl (S) 0 j<v {BR) ij@ (NOTE ) (Y M (MW CORD) N ' (0-BK) 0 b H B. A A KTS WRED for AND HOLD WTH M6C CORD TERMNATED AT 66-TYPE CONN BLK Fig. -0ptional Features with 4A Speakerphone (Sheet of ) Page 8 SSP i06_ jpg Scanned by Frank Harrell, {Cowboy Frank) Castle Rock, Colorado Feb 0,01 :59:16
9 SS 6, SECTON S TABLE A EXCLUSON KEY CONNECTONS EXCLUSON KEY EXCLUSON KEY S TEL SYS BL-W W-BL 0-W W-0 BL-V V-BL 0-V V-0 On any line la R* T* let H* ER ET EB EH lal or 1A R* T* EB H* ER ET EB EH *Terminal of line to be excluded t When other than line 1 is excluded on la KTS, disconnect, insulate, and store 0-W mounting cord conductor from terminal lb; connect balance lead conductor from line involved to lb. TABLE B PCKUP-SGNAL KEY CONVERSON TABLE C POLARTY GUARD CONNECTONS KEY TEL SET CONVERSON OPTONS 66A KEY S Y-BR BR S-R BR-BK ( OR P GUARD ASSEMBLY) REMOVE FROM CONNECT TO HPPPPP (Note) M M M X HPPPPS M M M SG NET. NET. POLARTY GUARD 565HK l!pppss M M SG X or HPPSSS M X SG X 565HKM HPPPP*S* M M 5H t HPPP*P*S* M X 5H t HPP*P*P*S* X X 5H t Dial Line Switch BK G-W w RR c c T s s * These arrangements use line switch controlled ground for common signal key used with private or intercommunicating lines. Common signal should be used to operate a common signal relay. Do not wire directly to a buzzer. Polarity Guard G w RR c t Connect to the same terminals as (BR) line switch lead depending on option and KTS required. Note: To convert from pickup (locking) to signaling (nonlocking) remove the or P-1A89 screw detail at the key position being converted. Page 9 9 Pages SSP i06_197S jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 0,01 :59:4
SERVICE 2565HK AND 2565HKM TELEPHONE SETS
BEU SYSTEM PRACTCES AT & TCo Standard SECTON -54-405 ssue 7, November 1977 SERVCE 565HK AND 565HKM TELEPHONE SETS 1 GENERAL 101 This section provides connection information sets (Fig 1) for the 565HK (MD)
More informationSERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing
BELL SYSTEM Plant Series PRACTCES SECTON 502-67-40 ssue, December 970 AT&TCo Standard SERVCE 66-TYPE TELEPHONE SETS. GENERAL 66A3 the appropriate key must be separately ordered and installed. For ordering
More informationINTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE
BELL SYSTEM PRACTCES Plant Series SECTON 512-510-450 ssue 2, November 1970 AT&TCo Standard NTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTONS AND MANTENANCE 1. GENERAL 1.01 This section contains
More informationSERVICE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MAINTENANCE AND CONNECTIONS
BELL SYSTEM PRACTCES AT&TCQ Standard SECTON 52-543-42 ssue 6, Noember 98 SERVCE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MANTENANCE AND CONNECTONS. GENERAL.O This section contains information for the
More informationTELEPHONE SETS 881A102, , 881C102, 881A103, , 881C103, 881A104, , AND 881C104
BELL SYSTEM PRACTCES AT & TCo Standard SECTON 53-2-18 ssue 3, January 1978 TELEPHONE SETS 881A12, 881812, 881C12, 881A13, 881813, 881C13, 881A14, 881814, AND 881C14 1. GENERAL 1.1 This section provides
More informationSERVICE 565HK, 565HKM, AND 565HKMS TELEPHONE SETS CONNECTIONS
BEU SYSTEM PRACTCES AT & TCo Standard SECTON 502-541-4 1 5 ssue 8, February 1980 SERVCE 565K, 565KM, AND 565KMS TELEPONE SETS CONNECTONS 1. GENERAL 1.01 This section contains information for the 565K (MD),
More information4A SPEAKERPHONE SYSTEM
BELL SYSTEM PRACTCES AT&TCo Standard SECTON 512-7-lOD ssue 2 September 1974 4A SPEAKERPHONE SYSTEM \ 1. DENTFCA TiON 1.1 The 4A speakerphone system is a hands-free voice switched system for use as a telephone
More informationAUXILIARY SIGNALS IDENTIFICATION, INSTALLATION, OPERATION, MAINTENANCE, AND CONNECTIONS
BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-11 0-1 00 ssue 12, October 1979 AUXLARY SGNALS DENTFCATON, NSTALLATON, OPERATON, MANTENANCE, AND CONNECTONS 1. GENERAL 1.01 This section provides information
More informationTELEPHONE SETS 910A AND 2910A IDENTIFICATION, INSTALLATION, AND CONNECTIONS
BELL SYSTEM PRACTCES AT&TCo Standard SECTON 503-200-101 luue 1, April 1974 TELEPHONE SETS 910A AND 2910A DENTFCATON, NSTALLATON, AND CONNECTONS 1. ENERAL 1.01 This section provides identification, installation,
More information4A SPEAKERPHONE COMPONENTS. IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE
BELL SYSTEM PRACTICES AT& TCo Standard SECTION 512-700-100 Issue 5, April 1979 4A SPEAKERPHONE COMPONENTS IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE 1. GENERAL 1.01 This section contains
More informationREFERENCE INDUCTIVE NOISE
BELL SYSTEM PRACTCES AT&TCo StCindard SECTON 500-12-100 luue 8, January 1973 REFERENCE NDUCTVE NOSE ENERAL 101 This section contains information to control and minimize the effects of inductive noise at
More informationSERVICE SPECIAL SAFEGUARD MEASURES SPECIAL SERVICE PROTECTION RADIO AND TELEGRAPH LOOPS
BELL SYSTEM PRACTCES Plant Series SECN 460-11 0-400 ssue 1, December 1969 AT & TCo Standard SERVCE SPECAL SAFEGUARD MEASURES SPECAL SERVCE PROTECN RADO AND TELEGRAPH LOOPS 1. GENERA L 1.01 This section
More information4A SPEAKERPHONE SYSTEM
BELL SYSTEM PRACTCES AT & TCo Standard SECTON 512-700-100 ssue 4, May 1978 4A SPEAKERPHONE SYSTEM 1. GENERAL 1.01 This section contains identification, installation, operation, and maintenance information
More informationVOICE CONNECTING ARRANGEMENTS QKT AND QKTBT 30-TYPE VOICE COUPLER
BSP 463-311-100-i05_1974.Q3.Q1.jpg Scanned by Frank Harrell (CowboyFrank) Castle ock. Colorado Feb 23,2016 21:24:32 BELL SYSTEM PACTCES AT&TCo Standard SECTON 463-311-100 ssue 5, March 1974 VOCE CONNECTNG
More informationMATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I
ELL SYSTEM PRACTCES AT&TCo Stondord ssue 2, December 1971 MATRX LOCK-1 A 1 DENTFCATON, NSTALLATON, WRNG, AND MANTENANCE 1. GENERAL 1.01 This section provides identification, installation, wiring and maintenance
More informationCOMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS
BELL SYSTEM PRACTICES AT & TCo Standard SECTION 518-0 1 0-1 08 Issue 3, October 1976 COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS 1. GENERAL 1.01 This section provides a general description of common
More information21 A COMMUNICATION SYSTEM (COM KEY* 2152)
BELL SYSTEM PRACTCES AT & TCo Standard SECTON 518-450- 11 0 ssue 1, December 1976 21 A COMMUNCATON SYSTEM (COM KEY* 2152) CONTENTS PAGE CONTENTS PAGE Multiline Pickup 33 1. GENERAL 2 Hold and llumination
More informationr--- INSIDE WIRE CABLE
Scanned b Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 09, 01 14:6 :"ol. BELL SYSTEM PRACTICES Plant Series SECTION 461-60-1 00 Issue 1, January 1968 AT&TCo Standard CONNECTING BLOCKS 4A, 44A,
More informationINTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT
BSP 463-300-112-i01_1973-11.01.jpg Scanned by Frank Harrell (CowboyFrank) Castle Rock. Colorado Feb 23.2016 21:15:56 BELL SYSTEM PRACTCES AT&TCo Standard SECTON 463-300-112 ssue 1, November 1973 NTERCONNECTNG
More informationAUXILIARY SIGNALS IDENTIFICA lion
BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-110-100 ssue 10, Odober 1974 AUXLARY SGNALS DENTFCA lion 1. GENERAL 1.01 This section provides identification, installation, operation, maintenance, and
More informationBELL SYSTEM PRACTICES Plant Series
BELL SYSTEM PRACTCES Plant Series SECTON 58469MS ssue B, August, 963 M. S. T. & T. Co. CON COLLECTOR TELECART dentification, nstallation and Maintenance. DENTFCATON. The Coin Collector Telecart consists
More informationRADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS
BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCo Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction
More informationKS TELETRAINER DESCRIPTION AND MAINTENANCE
BELL SYSTEM PRACTICES AT&TCo Standard SECTION 473-411-100 Issue 4, January 1973 KS-16605 TELETRAINER DESCRIPTION AND MAINTENANCE 1. GENERAL 1.01 This section covers the description and maintenance of the
More informationCONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE. (5) Tighten screw.
BELL SYSTEM PRACTICES AT&TCo Standard SECTION 461-604-100 Issue 2, August 1971 CONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE 1. GENERAL 1.01 Reissued to add information on 183B2
More information* * * * * * * * * INSTALLATION AND MAINTENANCE
.-- )., TYPE CCRP RECTFERS * * * * * * * * * NSTALLATON AND MANTENANCE SERVCE MANUAL 595 CONTENTS Page... V. v. V. TABLE... V. NTRODUCTON..... DESCRPTON. OPERATON... A. NPUT VOLTAGE... B. CHARGNG BATTERES..
More informationDATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES
BELL SYSTEM PRACTCES AT&TCo Stondard. GENERAL 2. TEST EQUPMENT CARRER MONTORNG TEST A. Far-End Carrier B. Near-End Carrier CARRER SHFT TEST LOOP-BACK TEST DATA SETS 1 08D- AND 1 08E-TYPES SNGLE PRVATE
More informationDESIGNATION STRIPS AND CARDS
BELL SYSTEM PRACTCES AT& TCo Sandard SECTON 501-150-1 02 ssue 5, March 1978 DESGNATON STRPS AND CARDS 1. GENERAL 1.01 Designaion srips and cards are used o indicae on which key or pushbuon a paricular
More informationREFERENCE 1 A 1 KEY TELEPHONE SYSTEM. "TOUCH-TONE n ADAPTERS
BELL SYSTEM PRACTICES AT&TCo Standard Issue 2, September 1971 REFERENCE 1 A 1 KEY TELEPHONE SYSTEM "TOUCH-TONE n ADAPTERS 1. GENERAL 1.01 This section is reissued to change relay designation H3 to L3 for
More informationCOMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS
AT & TCo Standard SECTON 518-010-108 ssue 5, November 1980 COMMON AUDBLE SGNALNG KEY TELEPHONE SYSTEMS 1. GENEAL 1.01 This section provides a general description of common audible signaling arrangements,
More informationAUXILIARY KHZ PILOT SUPPLY TESTS
BELL SYSTEM PRACTCES SECTON 356-011-505 AT&TCo Standard ssue 1, June 1971 L MULTPLEX COMMON TERMNALS EQUPMENT AUXLARY 31592-KHZ PLOT SUPPLY TESTS An auxiliary 31592-kHz pilot supply (Fig 1) provides pilot
More informationKEY TELEPHONE UNIT 237-TYPE IDENTIFICATION, OPERATION, AND CONNECTIONS
ELL SYSEM PACCES A&Co Standard SEC 518310407 ue 8, May 1974 KEY ELEPHE UN 237YPE DENFCA, OPEA, AND CNECS 1. GENEAL 1.01 hi ection i reiued to: Delete Speakerphone Sytem No. la and lal connection Add Speakerphone
More informationREFERENCE 500E/F, 500H, 500L/M, 500P, 500R/S, 500U, 500W, 500Y, 500AD, 501F, 501P, 501U, 5148, AND 5168 TELEPHONE SETS
BELL SYSTEM PACTCES AT&TCo Standard SECTON 52-51-115 ssue 2, May 1971 EFEENCE 5E/F, 5H, 5L/M, 5P, 5/S, 5U, 5W, 5Y, 5AD, 51F, 51P, 51U, 5148, AND 5168 TELEPHONE SETS 1 ENEAL 11 This section provides identification,
More informationDATA SET 109B TYPE DESCRIPTION
BELL SYSTEM Plant Series PRACTCES SECTON 312-802-100 ssue 1, December 1967 AT&TCo Swdard DATA SET 109B TYPE DESCRPTON 1. GENERAL 1.01 This section describes Data Set 109B type (109B1 and 109B2) physically
More informationTWO-POINT PRIVATE LINE TELEPHONE CIRCUITS TEST PROCEDURES
BELL SYSTEM PRACTCES SECTON 310-300-500 AT&TCo Standard ssue 7, June 1975 TWO-PONT PRVATE LNE TELEPHONE CRCUTS VOCE ONLY TEST S 1. CONTENTS GENERAL...........1 PAGE always be referred to for TLP levels,
More informationINPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT
BEU SYSTEM PRACTCES SECTON 356-165-501 A7&TCa Standard ssue 4, May 1980 NPUT AND OUTPUT POWER ADJUSTMENTS PRMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRER ANALOG MULTPLEX TERMNAL EQUPMENT This section explains
More informationBACKBOARDS IDENTIFICATION AND INSTALLATION
&ELL SYSTEM PRACTICES AT&TCo Standard SECTION 463-130-1 00 Issue 10, December 1971 BACKBOARDS IDENTIFICATION AND INSTALLATION 1 GENERAL 101 This section provides information on common use backboards Refer
More information28G AND G-1 ELECTRICAL SERVICE UNITS
19 American Telehone and Telegrah Comany Printed in U.S. A. BELL SYSTEM PRACTCES Teletyeriter and Data Station SECTON P. ue, February, 19 AT&TCo Standard G AND G-1 ELECTRCAL SERVCE UNTS WRNG DAGRAM 1.
More informationRADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE
AT & T PRACTICE Standard AT & T 500-150-100 Issue 11, July 1984 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE 1. GENERAL 1.01 This practice contains information
More informationSERVICE 1 A2 KEY TELEPHONE SYSTEM KEY SERVICE UNITS 550- AND 551-TYPE
BELL SYSEM PRACCES A & Co Standard SECON 5825407 ssue, uly 976 SERVCE A2 KEY ELEPHONE SYSEM KEY SERVCE UNS 550 AND 55YPE. GENERAL.0 his section provides identification, installation, connection, and maintenance
More informationOFFICE CHANNEL UNIT AND AUXILIARY DIGITAL DATA SYSTEM
AT& T PRACTCE!krnclarct AT&T 314-910-500 ssue 6, December 1986 OFFCE CHANNEL UNT AND AUXLARY CRCUTS TEST S DGTAL DATA SYSTEM CONTENTS PAGE nstallation Testing 1. GENERAL...........1 2. LATCHNG LOOPBACK
More informationMETALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD)
BELL SYSTEM PRACTCES AT&TCo Standard ssue 1, November 1979 METALLC FACLTY TERMNAL LOOPSTART AND GROUNDSTART TO DX OR E&M SGNALNG CONVERTERS (J99343FA, FB, FC, AND FD) NSTALLATON AND TESTNG,. CONTENTS PAGE
More informationnstallation EasamPhon& Key Telephone System IIll~lllll! llllllllll llllllllll llllllllll
nstallation EasamPhon& Key Telephone System ll~lllll! llllllllll llllllllll llllllllll 1. :.: : CONTENTS. 1. HOW TO FOLLOW THE NSTALLATON PROCEDURE... 1 2. PACKNG MATERALS AND EXPLODED VEW... 2 2.1 PACKNG
More information75A-4 MODIFICATION FOR BUSHIPS. The purpose of this supplement is to show the changes in the 75A-4
75A-4 MODFCATON FOR BUSHPS GENERAL The purpose of this supplement is to show the changes in the 75A-4 nstruction Book (Collins part number 520 5052 00) necessary to make it agree with the-changes made
More information4-WIRE ORDER CIRCUIT TESTS
(a) Frequency: 1 khz (b) Power: Between -40 dbm and + 10 dbm NOTICE Not for use or disclosure outside the Bell System except under written agreement Printed in U.S.A. Page 1 BELL SYSTEM PRACTICES AT &
More informationTesters: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:
Table of Contents Testers: / Ohmmeters Insulation Measuring Instruments 51 METRAOHM 413 Article: M630A Digital Low-Resistance Measuring Instrument for Measuring Protective Conductors, Equipotential Bonding
More informationKS DIALER SWITCHBOARD AND MISCELLANEOUS KEY EQUIPMENT CONNECTIONS
SYST PCTCS Plant Serie SCTO 51212543 ue 2, December 197 T&TCa Standard S19594 D SWTCOD D SCOUS Y QUPT COCTOS 1. 1.1 Thi ection i reiued to: echange connection termination of dialer telehone cord at equiment,
More informationHalton (Milton) LRO #20
Miscellaneous KH Bankruptcy April 7, 1921 Sept 18, 1922 1 1452 BL Bylaws Nov 13, 1855 Sept 23, 1960 1 778 DH Deposits Oct 31, 1894 Sept 30, 1966 1 5088 GR General Register Jan 9, 1866 Sept 1, 1955 1 8276
More informationFLEX2 VERSION ALLFLEX 2 LEG / 3 SECTION HEIGHT ADJUSTABLE DESK **PATENT PENDING**
FLEX2 ALLFLEX 2 LEG / 3 SECTON HEGHT ADJUSTABLE DESK VERSON A NSTRUCTON MANUAL CONTENTS: FLEX-MU-2L3S-C3672-K4# FEET-ADJ-UNV-2430# V1 **PATENT PENDNG** MAX Load 265 lbs (120 KG) Equally Divided MAX Load
More informationE2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION
BELL SYSTEM PRACTCES AT&TCo Standard SECTON 20-644-4 ssue, April 975 E2 STATUS REPORTNG AND SYSTEM STATUS REPORTNG REMOTE DESCRPTON.,i) ~:.:..?,. 2. 3. 4. CONTENTS GENERAL.......... PHYSCAL DESCRPTON.....
More information400W, 5V - 188V Surface Mount Transient Voltage Suppressor
400W, 5V - 188V Surface Mount Transient Voltage Suppressor FEATURES Low profile package Ideal for automated placement Glass passivated junction Built-in strain relief Excellent clamping capability Fast
More informationJACKS AND PLUGS IDENTIFICATION AND SERVICE
BELL SYSTEM PRACTICES AT&TCo Standard SECTION 461-630-1 00 Issue 9, March 1976 JACKS AND PLUGS IDENTIFICATION AND SERVICE 1. GENERAL 1.01 This section provides identification, installation, and service
More informationRADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS
BELLSYSTEM PRACTICES SECTION500-150-11X) AT&TCo Standard Issue 7, January 1974 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL Transistors in amplifiers of some networks and handsets 1.01 This section
More informationINCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES
BELL SYSTEM PRACTICES Plant Series INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES-20150-01 OR ES-239844,,, I' I Issue 3, November,
More information7A COMMUNICATION SYSTEM"-COM KEY*"718 KEY TELEPHONE SYSTEM DESCRIPTION, ORDERING INFORMATION, AND OPERATION
BEU SYSTEM PRACTICES AT&TCo Standard SECTION 518-450-1 00 Issue S, February 1982 7A COMMUNICATION SYSTEM"-COM KEY*"718 KEY TELEPHONE SYSTEM DESCRIPTION, ORDERING INFORMATION, AND OPERATION CONTENTS PAGE
More informationREPLACEMENT PARTS LIST FOR MODELS:
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 7 Louisville,
More informationNDRpa/C I I SQUARED CDMPRNY. Solid State Logic Control. CONTENTS Description. Pages. FILE: Control Products Catalog
NDRpa/C Solid State Logic Control FLE: Control Products Catalog CONTENTS Description Pages Encapsulated nput & Output Devices.................. 2 Encapsulated Logic Devices................................
More informationREGISTRATION INTERFACE BRIDGED MULTIPLE TIP AND RING ARRANGEMENTS
BELL SYSEM PCCES & Co Provisional SECON -00-10 ssue, pril 1 1. GENEL 1.01 his section provides information on the standard wiring arrangements to be provided under the Federal Communications Commission
More informationSMAJ Series SMA/DO-214AC. Mechanical Data. Page <1> 29/01/10 V1.1. : Moulded plastic. : Pure tin plated lead free. : Indicated by cathode band.
SMA/DO-214AC Features: For surface mounted application. Low profile package. Built-in strain relief. Glass passivated junction. Excellent clamping capability. Fast response time : typically less than 1.0ps
More information1\. power 3A speakerphone systems.
BELL SYSTEM PRACTICES AT&TCo Standard SECTION 501-136-100 Issue 5, May 1972 STATION TRANSFORMERS IDENTIFICATION 1. GENERAL 1.01 This section is reissued to: Include KS-20426L3 transformer Change Read,
More information3444 CALIBRATION and ELECTRICAL INSPECTION PROCEDURE.
3444 CALIBRATION and ELECTRICAL INSPECTION PROCEDURE. C- PLATE VOLTAGE SWITCH POSITION. 1-4 194.5 5-8 84.6 9-10 30 11 17.8 The With plate voltage switch on position #11, short circuit the 17.8 ACV. overload
More informationStandard Plugs And Jacks
PUB47101 Bell System Voice And Data Communications TECHNCAL REFERENCE Standard Plugs And Jacks September 1979 RECTOR - BUSNESS PREMSES ENGNEERNG - DATA AND SPECAL SYSTEMS @American Telephone and Telegraph
More information150-BAUD PRIVATE LINE CHANNELS
BELL SYSTEM Plant Series PRACTCES SECTON 32-0-0 ssue, JUY 970 AT&TCo Standard 50-BAUD PRVATE LNE CHANNELS NTERFACE SPECFCATONS. DESCRPTON GENERAL.0 The purpose of this specification is to define the interface
More informationSTYLE F-40A DC/DC CONVERTER MAINTENANCE INSTRUCTIONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N )
An American-Standard Company.. SERVCE MANUAL 5799 (Not STYLE F-40A DC/DC CONVERTER MANTENANCE NSTRUCTONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N451033-0801) Description The Style F-40A
More informationBURIED PLANT -BURIED WIRE TERMINATIONS
BELL SYSTEM PRACTICES AT & TCo Standard SECTION 460-300-143 Issue 3, April 1978 BURIED PLANT -BURIED WIRE TERMINATIONS CONTENTS PAGE Information on E armored service wire 1. GENERAL 2. DISPOSITION OF UNTERMINATED
More informationDESCRIPTION TOOLS 2. DESCRIPTION OF TOOLS. NOTICE Not for use or disclosure outside the Bell System except under written agreement
BEU SYSTEM PRACTICES AT&TCo.....P+-.,,.,..-... -.+-x.@... j SOLDERING COPPERS AND IRONS 1. DESCRIPTION SECTION 074-7-105 Issue 3, September 1982 TOOLS 1. 1. GENERAL /,,? 4-----........ k. --- 4.*.~-~m
More informationCARRIER TRANSMISSION MAINTENANCE SYSTEM (CTMS) HOT TONE SCAN (HTS) AND QUICK HOT TONE SCAN (QHTS)
BELLSYSTEM PRACTCES AT& TCa Sttmdard SECTON 356-010-556 ssue 2, November 1976 L MULTPLEX COMMON TERMNALS EQUPMENT CARRER TRANSMSSON MANTENANCE SYSTEM (CTMS) HOT TONE SCAN (HTS) AND QUCK HOT TONE SCAN (QHTS)
More informationMIL-Spec Application Guide
Precision tool www.idealind.com 1-800-324-9571 Customer Service MIL-Spec Application Guide Only 5 MDI AIRFRAME TYPE A&B 45-2691 45-2691-1 45-2685 5 MDI HOOK-UP TYPE C 45-2694 45-2694-1 45-2693 45-2692
More informationV-119RT 19 STATION ROTARY-TONE INTERCOM
VSP-V-119RT Issue 6 V-119RT 19 STATION ROTARY-TONE INTERCOM GENERAL These instructions provide identification, installation, operation, connection and maintenance information for the V-119RT intercom unit.
More informationL CARRIER TYPE COAXIAL CABLE PREPARATION AND COMPLETION TESTS
. -.. BELL SYSTEM PRACTCES SECTON 330-200-501 Plant Series ssue 1, November 1969 AT&TCo Standard CABLE TESTNG L CARRER TYPE COAXAL CABLE PREPARATON AND COMPLETON TESTS 11 AND 13 COAXAL CONDUCTORS 1. 1.
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY NSTRUCTONS 5/S WAVE COMMERCAL GROUND PLANE WTH RADALS V58 Mac0 Manufacturing Co. - Division of Majestic Communications, nc. 4091 Viscount - Memphis, Tennessee 38118 (901) 794-9494 MAC0 ALPHA V58
More informationMODEL: DAST-20. Telemetering System
MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance
More informationc. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit.
BELL SYSTEM PRACTCES Plant Series 2. OPERATNG PRNCPLES CONTENTS PAGE B. Klystron Supply Regulator and nverter. D. Battery Voltage Alarm Circuit. 3. CRCUT DESCRPTON. A. Klystron Supply Regulator and nverter.
More informationMODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30
Model CM-30 Technical Practice November 2002 Issue 4 MODEL CM-30 Service Observing System 1. GENERAL 1.01 The DEES CM-30 is a complete 30 line service observing system with integrated talk assist capability.
More informationSERVICE AND TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE
BESYSTEM PRACTCES A7&TCo Standard SECTON 02-61201 ssue 7, September 1980 SERVCE 2630- AND 2631 -TYPE TEEPHONE SETS CONNECTONS AND MANTENANCE 1. GENERA 1.01 This section contains information for the 2630DA
More informationHoneywell. Overload protection is provided for the transformer. Large 38 VA transformer to power heatingcooling low voltage control systems.
Honeywell R829 FAN CENTER OR AT72H,J TRANS- FORMER (WTH APPROPRATE RELAY), PROVDES LOW VOLTAGE CONTROL OF LNE VOLTAGE FAN MOTORS AND AUX- LARY CRCUTS N HEATNG, COOLNG, OR HEATNG-COOLNG SYSTEMS. AT72H,J
More informationRADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS
BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCa Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction
More informationELECTRICAL. Hertz 50/60 Input Current.7 -.3A. -20 C to +45 C Operating Temp. -4 F to +113 F. Power Factor > 0.9 THD. 1.5 (38.1mm)
LESTRA-18V1 UPLIGHT Lestra-18V1 is a mid-bay fixture that achieves high lumen output levels. Lestra s diffused light is free from shadows and breaks. The fixture has an anodized finish providing excellent
More informationFebruary Superfast Surrey - Gainshare Deployment Postcodes
February 2017 - Superfast Surrey - Gainshare Deployment Postcodes It MUST be noted that the status of any Gainshare deployment postcode in this spreadsheet may change after BT have undertaken detailed
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationTELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION
BELLSYSTEM PRACTICES SECTION 502-710-200 Plant Series Issue 3, January, 1963 AT&TCo Standard TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION 1.00 INTRODUCTION 2.00 GENERAL 1.01 This section covers
More informationApprenticehips/ Traineeship
Role Apprenticehips/ Traineeship Vacancy Ref Postcode Closing Date Weekly Wage Web Development Apprentice A 778436 M1 1EA 05/04/2016 150 Digital and Social Media Apprenticeship A 791191 M1 1FR 08/04/2016
More information600W SURFACE MOUNT TRANSIENT VOLTAGE SUPPRESSOR SMB(DO-214AA) PACKAGE. SMBJ Series WILLAS ELECTRONIC CORP.
Working : 5.0 to 440 V Peak Pulae Power: 600 W SMB (DO-214AA) Features Glass passivated chip 600 W peak pulse power capability with a 10/1000 μs waveform, repetitive rate (duty cycle):0.01 % Low leakage
More informationWITH POWER NO. TRANSFER,UNCT
No..665 WTH POWER NO. TRANSFER,UNCT 661 PRNTER GENERAL NFORMATON The No. 665 Power Transfer Unit supervises the AC power being supp.lied to Ademco s No. 660 Digital Dialer Receiver and the No. 661 Printer.
More informationJACKS AND PLUGS IDENTIFICATION AND SERVICE
BSP 461-630-100-i10_1979-02 01.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 09, 2012 15:14:23 BELL SYSTEM PRACTICES AT & TCo Standard SECTION 461-630-1 00 Issue 10, February 1979
More informationBX04 e BX10 series Medium resolution area sensors
e series area sensors warranty warranty features IP67 protection degree (IP69K special model) Complete protection against electrical damages Detection of objects with irregular shape ATEX models, cat.
More informationCalibration Procedures for DIHIT. (l)~c Voltage Display cali:e!:~~i~n(usinq variab~e r~s~stor R27) (.J. J I
Calibration Procedures for DHT (l)c Voltage Display cali:e!:in(usinq variabe rsstor R7) for Models KHP30S0 & KMP307S(except Model KMP300l l AC voltage G;neratorl" (J J LCD Disnlav A7 (0KV); Backliaht switch
More informationPT7M CL/CH /NL Voltage Detector
PT7M6218-6250CL/CH /NL Features Highly precision: ±1.5% (25 C); ±2.5%(-40 C to +85 C ); Low power consumption: 1.0μA @ 3.6V Vcc Detect voltage range: 1.8 to 5V in 100mV increments Operating voltage range:
More informationMULTI-TONE GENERATOR V
PagePac by Issue 1 V-5335500 INTRODUCTION The Multi-Tone Generator (MTG) is a compact, versatile multi-tone generator as well as a Night Bell for a Telephone System. Six different information tones plus
More informationREPLACEMENT PARTS LIST FOR MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 37 Louisville, KY 05-037 SHIP TO: 39 Cane Run
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Series 5 Individual mounting Series Inline Bonded spool Air return Manual operator Solenoid 4-way pilot with balanced poppet 33 34 36 3 37 38 5 67 69
More informationSTATION DIALS 1. GENERAL. SECTION (15 Issued: 21 February 1974, Standard
NORTHERN ELECTRC PRACTCES r----f-il-in-g--ns-t-r-uc-t-io-n-s-:------.. GENERAL.0 This section contains identification maintenance and connection information for NE-35Q'type DGTONE* dials that are used
More information2E - 3E High Wind Kit Manual
Yag Dpole Vertcal (Patent# 6,677,914 E - 3E Hgh Wnd Kt Manual Antarctca at 7 mph SteppIR Antennas 11-116th Ave NE, Sute -, Bellevue, WA 984 Tel: 4-43-191 Fax: 4-46-441 Tech Support: 4-891-6134 www.steppr.com
More informationSECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS
9/8/98 AC 43.13-1B SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS 11-271. GENERAL. The electrical and electronic symbols shown here are those that are likely to be encountered by the aviation maintenance
More informationWARNING! Remove power to the pinsetter by turning off the circuit breaker and unplugging the main power cord to the electrical box.
A & A-2 Plug-In Motor Start Relay 12-862203-000 Packaging (1) 12-862203-000 Plug-In Motor Start Relay Package, contains: (1) 11-696644-000 Relay (1) 11-696645-000 Relay Base (2) 11-696684-000 Relay Clips
More informationwww. ElectricalPartManuals. com 61. -;. " ' ' t - " Type MTR Static Overcurrent Protection Package ... Westinghouse Electric Corporation
... December 1976 New nformation E,D,C/1994/DB Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, ndiana 47401 Static Control for All Reclosers '" 38-724 Page 1 Type MTR Static
More informationTerminal blocks Index
Terminal Index - Terminal SNK terminal....1.72 General information Features and benefits...1 -.3...4 Marking solutions...5 Panorama...6 -.7 Ordering details ZS4 Screw terminal...8 ZS6 Screw terminal...9
More informationAbsco Space Saver Shed Assembly Instructions Model: 23081SK
Assembly Instructons Model: 2308SK FRONT BASE LENGTH: 2.26m SIDE BASE LENGTH: 0.78m FRONT WALL HEIGHT:.80m REAR WALL HEIGHT:.95m CONCRETE SLAB 880mm 2360mm WHEN LAYING YOUR CONCRETE SLAB, CHAMFER THE 50mm
More informationPOLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 1 Laboratory Energy Sources
POLYTECHNIC UNIERSITY Electrcal Engneerng Department EE SOPHOMORE LABORATORY Experment 1 Laboratory Energy Sources Modfed for Physcs 18, Brooklyn College I. Oerew of the Experment Ths experment has three
More informationINSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)
MILLENNIUM HEAD PRESSURE CONTROL KIT FOR LOW AMBIENT APPLICATIONS INSTALLATION INSTRUCTION Supersedes: 530.70-N.8Y (399) 530.70-N.8Y (99) HEAD PRESSURE CONTROL FOR 208/230 & 0V 25, 30 & 0 TON MILLENNIUM
More informationFigure 1. DC-DC Boost Converter
EE36L, Power Electroncs, DC-DC Boost Converter Verson Feb. 8, 9 Overvew Boost converters make t possble to effcently convert a DC voltage from a lower level to a hgher level. Theory of Operaton Relaton
More information