MODEL: DAST-20. Telemetering System
|
|
- Fay Quinn
- 5 years ago
- Views:
Transcription
1 MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance Approval by Japan Approvals Institute for Telecommunications Equipment Isolation between telephone circuit, I/O and power Easy-to-handle plugin construction for each component: Communication Module, Modem Module, Lightning Arrester Self-diagnosis Monitor LED provided for contact I/O modules 0 (.0) 0 (.0) MODEL: DAST-0-[][]-K mm (inch) Code number: DAST-0 [][] K Specify a code from below for each [] and []. (e.g. DAST-0-MC-K) [] TRANSMISSION RATE : 0 bps : 00 bps [] I/O SECTION Master Station MC: Contact outputs, open collector outputs ME: Contact I/O, dry contact inputs open collector outputs MM; Analog outputs, voltage outputs MR: Analog I/O, voltage inputs voltage outputs MS; Contact & analog outputs open collector outputs voltage outputs MS; Contact inputs & analog outputs dry contact inputs voltage outputs MU: Analog & pulse outputs voltage outputs pulse outputs (open collector) MS: Contact, analog & pulse outputs open collector outputs voltage outputs pulse outputs (open collector) Local Station SA: Contact inputs, dry contact inputs SE: Contact I/O, dry contact inputs open collector outputs SG: Analog inputs, voltage inputs SR: Analog I/O, voltage inputs voltage outputs SS: Contact & analog inputs dry contact inputs voltage inputs SS: Contact outputs & analog inputs open collector outputs voltage inputs SP: Analog & pulse inputs voltage inputs dry contact pulse inputs SS: Contact, analog & pulse inputs dry contact inputs voltage outputs dry contact pulse inputs K: V AC APPLICATION TO NTT Application form is available at local NTT sales offices. Guide for Application for Dedicated Circuit Lease is provided for free for detailed explanation. COMMON SPECIFICATIONS Construction: lightning arrester, modem and I/O modules mounted on a chassis for surface mounting Connection Telephone circuit: M screw terminals Power & I/O: M. screw terminals Grounding: M screw terminal Material Chassis: black chromate-plated steel Housing: flame-resistant resin (black) Isolation: telephone circuit to I/O to power Self-diagnosis CPU: watch-dog timer DAST-0 SPECIFICATIONS ES- Rev. Page /
2 MODEL: DAST-0 Memory: sum check Power voltage: detects when the voltage supply to the CPU drops by 0 %. RUN output: contact opens when the self-diagnosis detects an abnormality or with a transmission error. Connection: DIN connector type terminals (wires up to. mm) Rating: 0V AC or 0V (resistive load) Response time: 0. μsec. Discharge current capacity: 000 A ( / 0 msec.) Maximum load current: 00mA Internal series resistance: approx. Ω including return Leakage current Between lines: 0 ma at ±. V Line to ground: 0 ma at ±0 V Maximum line voltage:. V MODEM & LIGHTNING ARRESTER 0 BPS TYPE Modem (model: MOD-K) Telephone circuit: NTT leased circuit, 0 bps Sending voltage: ±0 V max. Sending current: ±0 ma ± ma Transmission method: earth-return Transmission rate: 0 bps No. of circuits: Approval No.: L0-00 Lightning Arrester (model: MDP-MFA) Discharge voltage Between B C: ±0 V min. Between B or C A: ± V min. Between each line G: ±00 V max. Maximum surge voltage Between : ±0 V max. Between or : ±0 V max. Between each line G: ±0 V max. Response time: 0. μsec. Discharge current capacity: 000 A ( / 0 msec.) Maximum load current: 00 ma Internal series resistance: approx. 0 Ω including return Leakage current Between B C: 0 ma at ±0 V DC Between B or C A: 0 ma at ± V DC Between each line G: 0 ma at ±0 V DC 00 BPS TYPE Modem (model: MOD-K) Telephone circuit: NTT leased circuit,. khz Sending level: - to - dbm Receiving level: -0 dbm Transmission rate: 00 bps (half-duplex) Modulation: conform to ITU-T V. No. of circuits: Approval No.: D0-00JP Lightning Arrester (model: MDP-FT) Discharge voltage Between lines: ±. V min. Line to ground: ±00 V max. Maximum surge voltage Between lines: ± V max. Line to ground: ±0 V max. INSTALLATION Power input: V AC, 0/0 Hz, approx. VA max. Grounding: 00 Ω required for 0 bps type Operating temperature: - to + 0 C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface Weight:. kg (. lb) Permissible power failure duration: 0 ms Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 00 V minute (telephone circuit to I/O to power) 00 V minute (circuit to ground) TRANSMISSION TIME Simple Transmission Time The simple transmission time means the time between the start of data sending from the master station and the end of data sending from the local station. It means cycle of data transmission between the master station and the local station. It does not mean the time required for an input signal to be output. How to Calculate the Simple Transmission Time Transmission Rate 0 bps Simple Transmission Time (sec.) = (No. of data bytes from master station + No. of data bytes from local station) Transmission Rate 00 bps Simple Transmission Time (sec.) = (No. of data bytes from master station + No. of data bytes from local station) Effective Transmission Time The effective transmission time means the time required for a change of an input signal to affect its output signal. It varies between the minimum and maximum values, depending upon the timing of input change. Minimum Time = Simple Transmission Time Maximum Time = Simple Transmission Time DAST-0 SPECIFICATIONS ES- Rev. Page /
3 MODEL: DAST-0 MOUNTING REQUIREMENTS unit: mm (inch) M SCREW 0 (.) 00 (.) FRONT PANEL CONFIGURATION & TERMINAL ASSIGNMENT 0 bps TYPE (Transmission Rate Code: ) Lightning Arrester Modem I/O Module 0 C B A OFF ON SD RD FG U V LINE POWER T T T T SG RD SD 0 No. DESCRIPTION EXPLANATION RUN LED Red LED ON at normal status; OFF at anomaly detected by selfdiagnosis; blinks when there is anomaly in telephone circuit. Contact I/O Monitor LEDs RUN Contact Output Terminals Power Indicator LED Red LED ON with contact ON; provided only for contact I/O types Relay opens when an anomaly is detected. Red LED ON at normal status; OFF when the voltage level drops. Circuit Test SW Normally OFF; turned ON when testing only. Circuit Status Indicator LEDs Red LED; SD blinks during sending; RD blinks during receiving. Power Terminals Refer to the Terminal Connection. SG, RD, SD Terminals Circuit Test Terminals (T T, T T) 0 Circuit Connection Terminals Connected with the lightning arrester. (factory connected) Normally shorted with a jumper. Circuit connection is broken when it is removed (opened). Refer to the Terminal Connection. Grounding Terminal Refer to the Terminal Connection. DAST-0 SPECIFICATIONS ES- Rev. Page /
4 MODEL: DAST-0 00 bps TYPE (Transmission Rate Code: ) Lightning Arrester Modem I/O Module SD RD FG U V 0 LINE POWER P P S S 0 No. DESCRIPTION EXPLANATION RUN LED Red LED ON at normal status; OFF at anomaly detected by selfdiagnosis; blinks when there is anomaly in telephone circuit. Contact I/O Monitor LEDs RUN Contact Output Terminals Power Indicator LED Red LED ON with contact ON; provided only for contact I/O types Relay opens when an anomaly is detected. Red LED ON at normal status; OFF when the voltage level drops. Master/Local SW Designating the Master and Local Stations (factory set) Circuit Status Indicator LEDs Red LED; turn ON according to the status of telephone circuit Power Terminals Refer to the Terminal Connection. Modem Circuit Terminals Circuit Connection Terminals Connected with the lightning arrester. (factory connected) Refer to the Terminal Connection. 0 Grounding Terminal Refer to the Terminal Connection. Modem Circuit Connector Not used. CONNECTION DIAGRAM 0 bps TYPE (Transmission Rate Code: ) 00 bps TYPE (Transmission Rate Code: ) TELEPHONE CIRCUIT POWER RUN CONTACT U V FG RD SD A B C SG RD SD I/O MODULE Refer to later pages for connection of each I/O type. G 00 ohms max. LIGHTNING ARRESTER MODEM TELEPHONE CIRCUIT POWER RUN CONTACT U V L L S S P P LINE LINE I/O MODULE Refer to later pages for connection of each I/O type. G LIGHTNING ARRESTER MODEM Remark : Broken line connections are already done at factory. Do not remove those cables already wired when wiring to power supply (Terminals of the Modem) and ground terminals (G). Remark : Be sure to ground (00 ohms or less) for 0 bps type which emploies the earth-return method. DAST-0 SPECIFICATIONS ES- Rev. Page /
5 EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) MODEL: DAST-0 (.) 0 (.) 0 (.0) 0 (.) 00 (.) 0 (.0) 0 (.) min. (.) Shape of the lightning arrester changes according to model No. Wiring Procedure of DIN Terminals PIN TERMINAL PHOENIX AI.-BK RECOMMENDED MULTI-STRAND CABLE:. mm SCREWDRIVER ( ) SOLID CABLE. dia. Remove cover. mm SYSTEM DESCRIPTIONS DAST-0 Master Station DAST-0 Local Station Leased Telephone Circuit Lightning Arrester for Power Supply (model: MA-00) Lightning Arrester for Power Supply (model: MA-00) Power Source Power Source DAST-0 SPECIFICATIONS ES- Rev. Page /
6 MODEL: DAST-0 MASTER,CONTACT OUTPUT MODEL: DAST 0 []MC-K Code number: DAST-0 []MC K Specify a code from below for []. (e.g. DAST-0-MC-K) [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC OPEN COLLECTOR OUTPUT Rating: 0 V ma Number of data bytes: 0 OUTPUT TERMINAL CONNECTION 0 Do Do Do Do DAST-0 SPECIFICATIONS ES- Rev. Page /
7 MODEL: DAST-0 LOCAL, CONTACT INPUT MODEL: DAST 0 []SA-K Code number: DAST-0 []SA K Specify a code from below for []. (e.g. DAST-0-SA-K) [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC DRY CONTACT INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω Number of data bytes: INPUT TERMINAL CONNECTION V 0 Di Di Di Di DAST-0 SPECIFICATIONS ES- Rev. Page /
8 MODEL: DAST-0 MASTER,CONTACT I/O MODEL: DAST 0 []ME-K I/O TERMINAL CONNECTION V Code number: DAST-0 []ME K Specify a code from below for []. (e.g. DAST-0-ME-K) Di Di Di Di [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Do Do Do Do DRY CONTACT INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω OPEN COLLECTOR OUTPUT Rating: 0 V ma Number of data bytes: DAST-0 SPECIFICATIONS ES- Rev. Page /
9 MODEL: DAST-0 LOCAL, CONTACT I/O MODEL: DAST 0 []SE-K I/O TERMINAL CONNECTION V Code number: DAST-0 []SE K Specify a code from below for []. (e.g. DAST-0-SE-K) Di Di Di Di [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Do Do Do Do DRY CONTACT INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω OPEN COLLECTOR OUTPUT Rating: 0 V ma Number of data bytes: DAST-0 SPECIFICATIONS ES- Rev. Page /
10 MODEL: DAST-0 MASTER, ANALOG OUTPUTS MODEL: DAST 0 []MM-K Code number: DAST-0 []MM K Specify a code from below for []. (e.g. DAST-0-MM-K) [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. Accuracy: ±0. % Number of data bytes: 0 Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) OUTPUT TERMINAL CONNECTION Ao Ao Ao Ao 0 DAST-0 SPECIFICATIONS ES- Rev. Page 0/
11 MODEL: DAST-0 LOCAL, ANALOG INPUTS MODEL: DAST 0 []SG-K Code number: DAST-0 []SG K Specify a code from below for []. (e.g. DAST-0-SG-K) [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) INPUT TERMINAL CONNECTION Ai Ai Ai Ai 0 DAST-0 SPECIFICATIONS ES- Rev. Page /
12 MODEL: DAST-0 MASTER, ANALOG I/O I/O TERMINAL CONNECTION MODEL: DAST 0 []MR-K Code number: DAST-0 []MR K Specify a code from below for []. (e.g. DAST-0-MR-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) Ao 0 Ao Ao Ao VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
13 MODEL: DAST-0 LOCAL, ANALOG I/O I/O TERMINAL CONNECTION MODEL: DAST 0 []SR-K Code number: DAST-0 []SR K Specify a code from below for []. (e.g. DAST-0-SR-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) Ao 0 Ao Ao Ao VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
14 MODEL: DAST-0 MASTER, CONTACT & ANALOG OUTPUTS OUTPUT TERMINAL CONNECTION MODEL: DAST 0 []MS-K Code number: DAST-0 []MS K Specify a code from below for []. (e.g. DAST-0-MS-K) Ao Ao Ao Ao [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Do Do Do Do VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. OPEN COLLECTOR OUTPUT Rating: 0 V ma Accuracy: ±0. % Number of data bytes: 0 Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
15 MODEL: DAST-0 LOCAL, CONTACT & ANALOG INPUTS INPUT TERMINAL CONNECTION MODEL: DAST 0 []SS-K Code number: DAST-0 []SS K Specify a code from below for []. (e.g. DAST-0-SS-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC V 0 Di Di Di Di VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) DRY CONTACT INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω Accuracy: ±0. % Number of data bytes: 0 Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
16 MODEL: DAST-0 MASTER, CONTACT INPUTS & ANALOG OUTPUTS OUTPUT TERMINAL CONNECTION MODEL: DAST 0 []MS-K Code number: DAST-0 []MS K Specify a code from below for []. (e.g. DAST-0-MS-K) Ao Ao Ao Ao [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC V 0 Di Di Di Di DRY CONTACT INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
17 MODEL: DAST-0 LOCAL, CONTACT OUTPUTS & ANALOG INPUTS INPUT TERMINAL CONNECTION MODEL: DAST 0 []SS-K Code number: DAST-0 []SS K Specify a code from below for []. (e.g. DAST-0-SS-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Do Do Do Do VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) OPEN COLLECTOR OUTPUT Rating: 0 V ma Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
18 MODEL: DAST-0 MASTER, ANALOG & PULSE OUTPUTS OUTPUT TERMINAL CONNECTION MODEL: DAST 0 []MU-K Code number: DAST-0 []MU K Specify a code from below for []. (e.g. DAST-0-MU-K) Ao Ao Ao Ao [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Po Po Po Po VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. PULSE OUTPUT (open collector) Rating: 0 V ma Frequency: 0 Hz max. Accuracy: ±0. % Number of data bytes: 0 Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
19 MODEL: DAST-0 LOCAL, ANALOG & PULSE INPUTS INPUT TERMINAL CONNECTION MODEL: DAST 0 []SP-K Code number: DAST-0 []SP K Specify a code from below for []. (e.g. DAST-0-SP-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC V 0 Pi Pi Pi Pi VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) PULSE INPUT Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω Frequency: 0 Hz max., pulse width 0 0 % Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
20 MODEL: DAST-0 MASTER, CONTACT, ANALOG & PULSE OUTPUTS OUTPUT TERMINAL CONNECTION MODEL: DAST 0 []MS-K Code number: DAST-0 []MS K Specify a code from below for []. (e.g. DAST-0-MS-K) Ao Ao Ao Ao [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC 0 Po Po Do Do VOLTAGE OUTPUT Range: V DC (operational range 0.. V) Load resistance: 0 kω min. OPEN COLLECTOR & PULSE OUTPUT Capacity: points each Rating: 0 V ma Pulse output frequency: 0 Hz max. Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page 0/
21 MODEL: DAST-0 LOCAL, CONTACT, ANALOG & PULSE INPUTS INPUT TERMINAL CONNECTION MODEL: DAST 0 []SS-K Code number: DAST-0 []SS K Specify a code from below for []. (e.g. DAST-0-SS-K) Ai Ai Ai Ai [] TRANSMISSION RATE : 0 bps : 00 bps K: V AC V 0 Pi Pi Di Di VOLTAGE INPUT Range: V DC (operational range 0.. V) Input resistance: MΩ min. (00 kω min.) DRY CONTACT & PULSE INPUT Capacity: points each Contact detecting voltage: V DC ON current/resistance: ma / 00 Ω OFF current/resistance: 0 μa / 00 kω Pulse output frequency: 0 Hz max., pulse width 0 0 % Accuracy: ±0. % Number of data bytes: Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) DAST-0 SPECIFICATIONS ES- Rev. Page /
MODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationMODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More informationMODEL: JPR2. Plug-in Signal Conditioners M-UNIT
MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationMODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationMODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection
Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of
More informationMODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series
MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationMODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.
MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationMODEL: M1EXT. with Display M1E Series
2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationMODEL: WL40MW1F. Wireless I/O WL40F Series
Wireless I/O WL40F Series WIRELESS GATEWAY (Modbus-RTU Transparent 900MHz Band Wireless Device (child device)) FUTIONS & ATURES This unit Incorporates 900MHz band wireless module. Works as a gateway between
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationMODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series
Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More informationGeneral specifications and features
General specifications and features General specifications and features Table 1 General AC/DC/Relay DC/DC/Relay DC/DC/DC Order number 6ES7 212-1BE31-0XB0 6ES7 212-1HE31-0XB0 6ES7 212-1AE31-0XB0 Dimensions
More informationMODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]
MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationNPN TRANSISTOR OUTPUT MODULE
INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as
More informationMODEL: 27HU 27-UNIT MODEL: 27HU [1][2]
Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication
More informationMODEL: TC10EM. Temperature Controller TC10 Series
Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More informationDISCRETE INPUT MODULE, 16 points
INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationDigital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment
More informationGeneral Specifications
General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type
More informationAnalog Timer TTL Series
Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification
More informationMulti Function Timer with Free power, Compact size W38 H42mm
Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)
More informationIndustrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America
World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationRamp/Soak Temperature Controller REX-P250
EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern
More informationDIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS
DIN SIZE ANALOG MULI-ANGE CYCLIC WIN IMES UL File No.: E122222 CSA File No.: L39291 FEAUES A single twin timer unit that repeats (variable) ON/OFF. Multiple ranges with a.1 s to 5 h time specification
More informationPalm-sized, 16-channel Relay Terminals
Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive
More informationPPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)
INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any
More informationMODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step
More informationFA Wireless SS Terminals
FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and
More informationEnclosed Power Supplies
, 000 Watt Features Compact metal case with screw terminal block Dual and triple output models with isolated outputs Universal input VAC EMI/EMC compliance with E 000-- and E 000-- Compliance to E 000--
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More informationJPQ2 PULSE ACCUMULATOR
INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as
More information2.1 General Specifications
Chapter 2. 2.1 General Specifications Table 2.1 shows general specifications of the GLOFA GM series and MASTER-K series. No Item Specifications Standards 1 2 3 4 Operating ambient temperature Storage ambient
More information1 Model 3153 Automatic Insulation Voltage Withstand Testing Voltage Control from a PC Full Remote Control All test parameters can be controlled by RS-232C or GP-IB, including test voltage, cut-off current,
More informationMODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors
Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationPLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationGeneral Specifications
General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can
More informationAn RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.
The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial
More informationGeneral Specifications
General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless
More informationIMS51 Series Driver 5 Phase Stepper Driver Units
IMS51 Series Driver 5 Phase Stepper Driver Units A compact package matching most existing motors 100~120Vac or 200~220Vac Single Phase Power Input Opto-isolated inputs and outputs Auto-current down feature
More informationSHIMADEN PROGRAM CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and
More informationSolid State Pressure Sensors D8M
Solid State Pressure Sensors D8M Solid State Pressure Sensors with Analog, Pulse or Frequency Outputs Compact housing measures 30L x 30W x 12.4H mm. Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing
More informationKNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION
More informationModel 6517B Electrometer / High Resistance Meter Specifications
VOLTS Accuracy (1 Year) 1 / C 2V 10µV 0.025+4 0.003+2 20V 100µV 0.025+3 0.002+1 200V 1mV 0.06+3 0.002+1 NMRR: 2V and 20V range > 60dB, 200V range > 55dB. 50Hz or 60Hz 2 CMRR: >120dB at DC, 50Hz or 60Hz.
More informationMOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals
MOS FET Relay GVM SSR for Switching Analog Signals, with an Insulation Value of. kvac between Input and Output Terminals Switching minute analog signals. Linear voltage and characteristics. Switching AC
More informationMulti-point Temperature Controller
Multi-point Temperature Controller Controls Up to Eight Zones, Built-in DeviceNet Communications Applications include plastic injection and extrusion machines, and continuous temperature control processes
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationHigh Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.
98585A High Intensity LED Stroboscope Digital Tachometer DT-361/365 Instruction manual Be sure to read before use. Before use, please carefully read these safety precautions as well as instructions, and
More informationCylindrical type proximity sensor
Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in
More information60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W
SPECIFICATION MODEL OUTPUT INPUT PROTECTION - - -0-4 -0 - -4-48 -4 DC VOLTAGE V V 0V 4V 0V V 4V 48V 4V CONSTANT CURRENT REGION Note.4 7. ~V 9 ~ V ~ 0V 4.4 ~ 4V 8 ~ 0V. ~ V. ~ 4V 8.8 ~ 48V.4 ~ 4V RATED
More informationGeneral Specifications
General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More information80W Single Output Switching Power Supply
SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE CONSTANT CURRENT REGION Note.4 RATED CURRENT RATED POWER RIPPLE & NOISE (max.) Note. 0mVp-p 0mVp-p 0mVp-p 0mVp-p
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationBOX TRANSDUCER TYPE CODE DESIGNATION
TYPE CODE DESIGNATION TYPE CODE DESIGNATION SMALL SIZED AC TRANSDUCER TT2-90A series (1) TT2 (2) A - (3) (1) Kind of input (2) Kind of outer case and its dimensions Mark A or AE V or VE W WV S P SP F Kind
More informationPEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION
The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety,
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance
1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationREVISIONS 06/26/06 YS TEMPS FILE NAME: CAD1:MSWORD:PA DOC SCALE: NONE REV: D SH 1 OF 7 TITLE: OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION
REVISIONS REV DESCRIPTION DATE ISSUED BY - ISSUE 1 / A REVISIED OPERATING TEMP ON PAGE 4. 07/02/02 RJ OVP FOR 48V ON PAGE 2. REMOTE ON/OFF ON PAGE 2. B CHANGED CN4 ON PAGE 5 07/12/02 RJ C CHANGED D (MODELS
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationMODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same
More informationSLIM COMPACT SAFETY RELAY
SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile
More informationElectronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback
RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier
More informationINSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES
2001 INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES Safety Standards Measuring Instruments 3153 3159 3158 3154 ISO14001 JQA-E-90091 http://www.hioki.co.jp/ HIOKI company overview, new products,
More information16A POWER RELAY FOR MICRO WAVE OVEN
VDE 6A POWER RELAY FOR MICRO WAVE OVEN LE RELAYS (ALE) TMP type New FEATURES. Price competitive having better price competitiveness (New 4 mw only) 2. Supports magnetron and heater loads. Switching possible
More informationHIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))
TESTING HIGH INSULATI RELAYS (Conforming to the supplementary insulation class of EN Standards (EN)) TX-D RELAYS.9.9 8...9.9 8.. FEATURES Approved to the supplementary insulation class in the EN standards
More informationDistributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationINS500 Series Driver ( **CE Approved ) 5 Phase NanoDrive DC Type Driver Units
INS Series Driver ( **CE Approved ) Phase NanoDrive DC Type Driver Units A compact package matching most existing motors Vdc Supply Input High Resolution possible ( selectable up to, steps per revolution
More informationLOW-PROFILE SURFACE-MOUNT RELAY
TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance
13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO
More informationMODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration
More information