The Accurate and Compliant Test Solution Provider. Product Catalog

Size: px
Start display at page:

Download "The Accurate and Compliant Test Solution Provider. Product Catalog"

Transcription

1 The Accurate and Compliant Test Solution Provider 2018 Product Catalog

2 2

3 WhaleTeq Company Profile WhaleTeq Global Customers WhaleTeq Test Solutions WhaleTeq Medical Device Test Solution 06 ECG Technology 22 EEG Technology 26 ESU Active Accessories 30 WhaleTeq Healthcare Wearable Test Solution 30 PPG Technology 36 ECG, PPG and PWTT Technology 42 Medical Standard Cross-reference Table 1

4 WhaleTeq Company Profile The Accurate and Compliant Test Solution Provider WhaleTeq Co., Ltd. is founded by a team of experts specializing in test equipment and medical certifications. We strive to offer simple, accurate, and compliant test solutions to help customers save time, increase design quality, and go to market with efficiency. We design, produce, and sell reliable test solutions for medical devices and healthcare wearables all around the world since

5 WhaleTeq Global Customers WhaleTeq has been devoting to ECG standard testing tools for years and is the global leading provider offering qualified test tools for medical device manufacturers and laboratories. In 2014, we expanded our product lines to provide test solutions of healthcare wearables. During the period we firstly launched the optical heart rate simulator with PPG technology, capable of verifying heart rate accuracy in a measurable way. Till now, over 400 customers in 30 countries already adopted WhaleTeq's test solutions and proved WhaleTeq is capable of delivering effective test tools to reduce customer's efforts in testing. 3

6 WhaleTeq provides test solutions of accuracy and compliance with medical standards We strive to make your work easy. With our test solutions, engineers will be able to focus either on product design or product quality. No extra efforts getting acquainted with the standards and regulations. Also, our test solutions are also proved to be simple and accurate to decrease operating costs in the production line. WhaleTeq provides total test solutions for R&D, quality assurance, and production line! - founder of WhaleTeq, Nathan Lin 4

7 WhaleTeq Test Solutions Medical Device Test Solutions In accordance with international and China medical standards, WhaleTeq launched a series of test solutions regarding performance tests, database playback, database comparison and common mode rejection ratio test. Waveforms and parameters are all followed the requirement of medical standards. Healthcare Wearable Test Solutions Along with the popularization of telemedicine and IoT, new medical technology is going to be emerging in a foreseen future. Although there're no regulations or standards yet, WhaleTeq provides test solution of various test parameters and raw-data playback function to allow user to identify the specification and characteristics of DUT. 5

8 Medical Device Test Solution ECG Technology Including ECG performance tests, database waveform simulation, database comparison and common mode rejection ratio test. Compliant with the requirements of international medical standards of IEC , -2-27, -2-47, YY1079, YY1139, YY0782, YY0885, etc. 6

9 SECG 4.0 ECG Performance Tester SECG Assistant SECG Enhancement Software Pack MECG 2.0 ECG Database Player CDCA CTS/CSE Database Compliance Analyzer Software CMRR 3.0 Common Mode Rejection Ratio Tester HFCN High Frequency Coupling Network Test Fixture RDCA Rhythm Database Compliance Analyzer Software 7

10 SECG 4.0 ECG Performance Tester Standard Coverage: IEC IEC IEC AAMI EC11 AAMI EC13 AAMI EC38 AAMI EC57 YY1079 YY1139 YY0782 YY0885 JJG 760 JJG 1042 The Accurate and Comprehensive Tool Designed for ECG Compliance Tests Features and Benefits Single channel performance tester for diagnostic ECG, monitoring ECG and ambulatory ECG. Built-in test circuits per defined in ECG standards. Excellent shielding and grounding design allows output amplitude and frequency accuracy < ± 1%. DC offset and pacemaker signal output can be adjustable. Load and replay customized ECG waveforms. Alternative input of external generator for arbitrary waveforms. Software Development Kit (SDK) allows user to develop customized automatic test software with less efforts. 8

11 We Simplify and Explain the Procedures to Save Your Time SECG 4.0 Specifications Parameter Main output voltage accuracy Main output voltage resolution (DAC resolution) Specifications ±1% for amplitudes of 0.5mVpp or higher 2.5µV Frequency / pulse repetition rate accuracy ±1% Pulse duration / timing accuracy (excluding pacing) Pacing pulse width accuracy Pacing pulse amplitude accuracy, range Pacing pulse characteristics ±1ms ±5µs ±2mV pulse: ±1% >2mV pulse: ±10% Range: ±2mV to ±700mV Settling time <1% Overshoot <1% Rise/fall time 5µs Pacing pulse overshoot (intentional) Method A according to IEC Resistor tolerance ±1% Capacitor tolerance ±5% Precision 1000:1 divider (100KΩ:100Ω) ±0.1% Sample rate 5kHz ± 0.1% DC offset (fixed, noise free, sourced from internal super capacitor) DC offset (variable, may include up to 50µVpp noise) Power supply Environment 300mV ± 1% Setting ±1% or ±3mV USB +5Vdc supply (no separate power supply required) 0.5A (high power mode) 15 ~ 30 C 30 ~ 80% RH 9

12 MECG 2.0 ECG Database Player Standard Coverage: IEC IEC AAMI EC57 YY0782 YY0885 A True Analog ECG Database Generator for Your System Validation and Software Algorithms Evaluation Features and Benefits ECG database generator for diagnostic and ambulatory ECG. Generate waveforms simultaneously up to 8 channels and support 12 lead ECG. Embedded CAL, ANE, NST and biological waveforms. Directly support AHA, MIT, CU and PhysioNet format databases Extreme accuracy of output voltage accuracy < ± 8uV. Support raw-data playback function for user to play recorded waveforms from clinical trials. Software Development Kit (SDK) allows user to develop customized automatic test software with less efforts. 10

13 We Simplify and Explain the Procedures to Save Your Time MECG 2.0 Supported Medical Databases DB Full Name of Database Purpose Source # of Records Standards Test Requirements by standards CTS Clinical Trial Subject Calibration and Analytical ECGs Corscience 19 (3 ANA waveforms and 16 CAL waveforms) IEC Amplitude,global interval and duration CSE Common Standards for Quantitative Electrocardiography Biological ECGS INSERM 100 IEC Global interval AHA American Heart Association Evaluation of Ventricular Arrhythmia Detectors ECRI 80 (35 min each) IEC QRS, HR, VEB, VF MIT- BIH Massachusetts Institute of Technology Beth Israel Hospital Arrhythmia Database MIT-BIH 48 (30 min each) IEC QRS, HR, VEB, VF,SVEB, AF CU Creighton University Sustained Ventricular Arrhythmia Database MIT-BIH 35 (8 mins each) IEC VF NST Noise Stress Test Noise database (only supplied with the MIT BIH database) MIT-BIH 12 ECG (30 min each) + 3 noise IEC QRS, HR, VEB, SVEB, AF ESC European Society of Cardiology ST-T Database CNR, MIT- BIH 90 (2 hour each) IEC ST segment deviations or changes MECG 2.0 Specifications Item Details / Reference Value Output Channels The 8 output channels are provided through a network as specified in IEC to provide signals to 10 lead electrodes; in the device under test, this will be displayed as 12 leads. 8 outputs 10 lead electrodes 12 leads Voltage accuracy IEC specifies a limit of ±1%, but does not provide a lower limit (all systems must have a lower limit). An inferred specification of 1% ±5µV is derived from the device under test specification in IEC of 5% ±25µV. ±1% (>800µV) ±5µV ( <500µV) ±8µV (<800µV) Output noise level 0-150Hz Output noise should not influence the test. A value 5µV is suitable for this requirement. Can be verified by monitoring the signal in the device under test using a diagnostic filter setting. <5µV Time accuracy IEC does not provide any limits. An inferred limit from the device under test. An inferred limit of ±1% is used. The system s design accuracy exceeds 0.1% as a 100ppm crystal reference is used. ±1% Sampling rate A maximum sampling rate of 1kHz matches the sampling rates of ECG files. 1kHz (8 channels) Power supply Powered from the USB supply (5V 0.2A) N/A Environment Intended for normal laboratory environment. The selection of critical components such as reference voltages, DAC, precision resistors are known to be stable in the range shown C 10-95% RH 11

14 CMRR 3.0 Common Mode Rejection Ratio Tester Standard Coverage: IEC IEC IEC IEC YY1079 YY1139 YY0782 YY0885 ANSI / AAMI EC11 ANS I / AAMI EC13 The CMRR Tester Combining Accuracy, Convenience and Test Automation All Together Features and Benefits Designed for ECG, Patient Monitor, Holter and EEG CMRR and system noise testing. Double shielding structure to avoid internal and external noise interference. Built-in calibrated sine wave generator and Vc voltage measuring circuit to assure output accuracy level Adjustable knobs to select test standards and test parameters in standalone usage. CMRR Assistant software pack to simplify the standard into adjustable parameters and selectable options. Software Development Kit (SDK) allows user to develop customized automatic test software with less efforts. 12

15 We Simplify and Explain the Procedures to Save Your Time CMRR 3.0 Specifications Item Option Specifications Supply voltage 0.5 / / 20 / 2 / (70.71) (Vrms) ±1% CM point voltage / 10/ 1/ (35.355) (Vrms) ±1% ( 0.25Vrms ±2% ) Frequency 50 / 60 / 100 /120 (Hz) ±1% Electrode with Impedance Using knob to change electrode None/RA/LA/LL/V1/V2/V3/V4/V5/V6 /ALL Electrode without Impedance Using knob to change electrode RA/LA/LL/V1/V2/V3/V4/V5/V6 Imbalance impedance, R 51kΩ 51kΩ ±1% Imbalance impedance, C 47nF 47nF ± 5% DC offset Internal battery powered, can be added on RA/ LA/LL/V1 300mV ± 1% Up to 40hrs with intermittent use Voltage divider 11:1 using 110MΩ:10MΩ Ratio accuracy ±2% Environment Intended for normal laboratory environment. The selection of critical components is known to be stable in the range shown. The 110MΩ divider may be affected by high humidity in excess of 85% C 10-75% RH CMRR Assistant Software Pack Allows User to Test with Ease Follow the instruction step by step to proceed required tests Detailed test sequences for user to test with confidence 13

16 HFCN Test Fixture High Frequency Coupling Network Test Fixture Standard Coverage: IEC IEC YY1079 AAMI EC13 Designed for testing electrosurgical interference with ECG devices and patient monitor Features and Benefits Elaborated design offers convenience and safety. Dual modules to support different standard requirements. Built-in skin impedance 51k/47nF. Simulate 1mV ECG signal for ESIS. Power rating >300W and resistor inductance <5μH. 14

17 We Simplify and Explain the Procedures to Save Your Time HFCN Test Fixture Completely Compliant with: ESIO test of IEC , IEC , YY1079 and AAMI EC13 ESIS test of YY1079 and AAMI EC13 15

18 SECG Assistant SECG Software Enhancement Pack Standard Coverage: IEC IEC IEC YY1079 YY1139 YY0782 YY0885 JJG760 JJG1042 Increase the Test Efficiency with Less Efforts Features and Benefits Software enhancement pack to use with SECG 4.0. Simplify test sequences of medical standards into parameters and selectable options. Assist user to get acquainted with medical standards and decrease the overall testing time. 16

19 We Simplify and Explain the Procedures to Save Your Time Click to Complete the Required Tests with Proper Parameters Test Procedures and Pass Criterion to be Displayed for User to Test with Ease 17

20 CDCA CTS/CSE Medical Database Compliance Analyzer Software Standard Coverage : IEC YY 0782 A Quick Tool to Compare Database Test Result and Perfect Algorithm Features and Benefits Support digital and analog data input to ensure your algorithm fully meet the standard requirements. Test data can be imported automatically via the pre-defined file format or input manually. Intuitive software interface allows user to complete the comparison within a few mouse clicks. Comparison result can be exported to a report file. 18

21 We Simplify and Explain the Procedures to Save Your Time Supported Standards and Test Clauses Standard Test Clause Requirements for amplitude measurements IEC : Requirements for absolute interval and wave duration Measurements Requirements for interval measurements on biological ECGS Requirements for amplitude measurements 振幅测量的要求 YY (IEC : 2003) Requirements for absolute interval and wave duration Measurements 绝对间期和波形时限测量的要求 Requirements for interval measurements on biological ECGS 实际人体心电图时限测量的要求 Requirement for Noise 抗噪声测量稳定性的公布要求 4 Steps to Complete the Database Comparison Select standard and test clause Click Import Testing Data "button to get ECG testing data Click Compare button to start the comparison Test Result to be displayed or exported to a report file 19

22 RDCA Rhythm Database Compliance Analyzer Software Standard Coverage : IEC ANSI / AAMI EC57 YY 0885 A Quick Tool to Compare Database Test Result and Perfect Algorithm Features and Benefits Support digital and analog data input to ensure your algorithm fully meet the standard requirements. AI sync function unifies original TAF into comparable TAF. Discrepancy data and discrepancy timing can be displayed for advanced algorithm improvement. Intuitive software interface allows user to complete the comparison within a few mouse clicks. Comparison result is identical with PhysioNet WFDB library software and can be exported to a report file. 20

23 We Simplify and Explain the Procedures to Save Your Time Supported Standards and Test Clauses Standard Test Clause Clause Name IEC : Accuracy Controls and Instruments ANSI/AAMI EC57:2012 Testing and reporting performance results of cardiac rhythm and ST segment measurement Algorithms YY 自动分析 AI Sync function intelligently optimize the label position and time difference of TAF file 4 Steps to Complete the Database Comparison Test Annotation File Get Test Annotaion File (TAF) from ECG DUT Load TAF of ECG DUT Compare TAF with RDCA built-in Referernce Annotation File (RAF) Get Comparision Result 21

24 Medical Device Test Solution EEG Technology Including EEG performance test and compliant with international medical standard of IEC

25 SEEG100 EEG Performance Tester 23

26 SEEG 100 EEG Performance Tester Standard Coverage : IEC Your EEG Simulator Designed for Regulation Testing Features and Benefits Designed according to latest EEG regulation standard IEC :2012 Sophisticated electrical design enables the test system to output 1µV signal 9 channels with auto-select switches for users to test performance individually Built-in test circuits as defined in EEG standards with selection of 620kΩ/4.7nF for input impedance test Good shielding and grounding designs allow for higher accuracy A real-time single channel player for PhysioNet's EDF format waveforms and text/binary format waveforms IEC helper makes the test sequences easier than ever 24

27 We Simplify and Explain the Procedures to Save Your Time Simple and Effective Tool to Verify EEG Performance Adjustable parameters per IEC required Load customized waveform format Real-time waveform display Easy to download PhysioNet waveforms via EDF File Manager Optional IEC helper simplifies the medical standard into required parameters, test sequences and pass criteria SEEG 100 Specifications Parameter Main output voltage accuracy Main output voltage resolution (DAC resolution) Specifications ±1% for amplitudes of 0.2mVpp or higher 0.5µV Frequency / pulse repetition rate accuracy ±1% Pulse duration / timing accuracy ±1ms Resistor tolerance ±1% Capacitor tolerance ±5% Precision 1000:1 divider (100KΩ:100Ω) ±0.2% Sample rate 5kHz ± 0.1% DC offset (fixed, noise free, sourced from internal super capacitor) Power supply Environment 300mV ± 1% USB +5Vdc supply (no separate power supply required) 0.5A (high power mode) 15 ~ 30 C 30 ~ 80% RH 25

28 Medical Device Test Solution ESU Active Accessories Designed for IEC and Capable of generating signals with frequency ranging from 50 khz to 5 MHz, producing current over 200 marms, and sine wave with THD < 0.3%. 26

29 HFPA150 Neutral Electrode Impedance Tester 27

30 HFPA150 Neutral Electrode Impedance Tester Standard Coverage : IEC Simple and Convenient NE Contact Impedance Tester Features and Benefits Designed according to IEC :2009 clause for testing NE contact impedance Outputs 200mA into 0-50 Ω load from 50kHz to 5MHz Equipped with DDS (direct digital synthesis) technology for a stable frequency output Inbuilt current monitor port eliminating the need for expensive current probes 28

31 We Simplify and Explain the Procedures to Save Your Time Required Test Equipment Combination NEUTRAL ELECTRODES HFPA150 Scope DC PS Thermal meter NE contact impedance HFPA150 Test Setup HFPA150 Specifications Parameter Frequency range Maximum voltage Maximum Current Waveform Frequency Response THD Impedance Auxiliary equipment for contact impedance test Specifications 50 khz to 5 MHz 11 Vrms (~31 Vpp), 50 Ω >200 marms, 50 Ω Sine < ±0.8 db, 50 Ω <0.3% (-50.4 db), at 200 marms, 50 Ω, 1 MHz <3.2Ω + j0.4 μh Oscilloscopes (Ch1 connects with voltage probe to measure voltage, Ch2 connects with HFPA150 current monitoring BNC connector to measure the current value) Accuracy < ± 5% Frequency Range Connector Type Power Source Environment 50 khz to 5 MHz BNC Power Adapter Input: V, 50/60 Hz Output: 12 VDC / 2 A 15 ~ 30 C 30 ~ 80% RH 29

32 Healthcare Wearable Test Solution PPG Technology Designed for wearable with heart rate measurement function. WhaleTeq s PPG heart rate simulator not only offers adjustable parameters but also several features to verify your wearable design. 30

33 HRS200 Advanced PPG Heart Rate Simulator HRS100+ PPG Heart Rate Simulator 31

34 HRS200 Advanced PPG Heart Rate Simulator Effectively Verify Accuracy and Algorithm of Wearable with Heart Rate Measurement Function Features and Benefits Built-in LED to generate PPG waveform signals as the reflected optical signal of human skin Built-in photodiode to detect and display DUT LED behavior and brightness Built-in 40 clinical database records for AF, APC, VPC, and 1stAV block Adjustable parameters of heart rate (BPM), reflected skin brightness and PI (AC/DC) Raw data playback to validate system and improve algorithm effectively Command mode allows to conduct test quickly and repeatedly Noise simulation with adjustable amplitude parameter 32

35 We Simplify and Explain the Procedures to Save Your Time The Effective Tool for Validation and Verification Various types of waveforms with noise simulation Raw-data playback function allows to play recorded clinical waveforms repeatedly Easy to use commands to create customized test sequences Built-in 40 clinical database records (Optional) HRS200 Specifications Parameters Supported range / types Accuracy BPM BPM ( PC Software ); 30~240 BPM ( Standalone Usage ) ±1 BPM DC - HRS mode - Fine Tune mode 1 20 Level 100 mv 2500 mv N/A ±5 mv PI - HRS mode 0.1% 20% ( AC/DC, differs with DC level ) N/A AC - Fine Tune mode 0.75 mv 25 mv ( BNC measurement is magnified 100 times ) ±0.05 mv Lumen Lux ( 5 mm from diffusion film ) ±3 % Light Wavelength 525nm ±10 nm PD Sampling Rate <8 ksps ( Normal Mode of PC Software ) 30 ksps ( High Resolution Mode of PC software ) ±5μS S/N Ratio >51 db (with USB isolator) N/A Power - USB - Battery Type BAA battery x 3 N/A N/A Size (W x H x D) 13.5 (cm) x 7.6 (cm) x 6.12 (cm) N/A Temperature 10 C ~ 40 C N/A 33

36 HRS100+ PPG Heart Rate Simulator Effectively Verify Accuracy of Wearable with Heart Rate Measurement Function Features and Benefits Built-in LED to generate PPG waveform signals as the reflected optical signal of human skin Built-in photodiode to detect and display DUT LED behavior and brightness Adjustable parameters of heart rate (BPM), reflected skin brightness and PI (AC/DC) 34

37 We Simplify and Explain the Procedures to Save Your Time The Effective Tool for Validation and Verification Adjustable DC, PI and BPM parameters with photodiode detection function Easy to use commands to create customized test sequences HRS100+ Specifications Parameters Supported range / types Accuracy BPM BPM (PC Software); 30~240 BPM (Standalone Usage) ±1 BPM DC 1 20 Level N/A PI 0.1% 20% (AC/DC, differs with DC level) N/A Lumen Lux (5 mm from diffusion film) ±3 % Light Wavelength 525nm ±10 nm PD Sampling Rate <8 ksps (Normal Mode of PC Software) 30 ksps (High Resolution Mode of PC software) ±5μS S/N Ratio >51 db (with USB isolator) N/A Power - USB - Battery Type BAA battery x 3 N/A N/A Size (W x H x D) 13.5 (cm) x 7.6 (cm) x 6.12 (cm) N/A Temperature 10 C ~ 40 C N/A 35

38 Healthcare Wearable Test Solution ECG, PPG and PWTT Technology Designed for wearable with measurement function of multiple vital signs. WhaleTeq AECG series provide ECG, PPG and PWTT signals to verify system performance and algorithm thoroughly. 36

39 AECG100 ECG, PPG and PWTT Multifunction Tester 37

40 AECG100 The Innovative Simulator to Output ECG and PPG Analog Signals Simultaneously Standard Coverage : IEC , China YY0885 Adjustable time difference parameters to generate various Pulse Wave Transit Time (PWTT) Signals Features and Benefits 38 Compatible with healthcare wearables with ECG and PPG technologies. AECG100 includes ECG module of built-in test circuits with auto-select switches per ECG standard required and PPG module of carrying single channel or dual channel optical signals. AECG100 single channel PPG module offers optical waveforms simulating heart rate signals and dual channel PPG module offers optical waveforms simulating SpO2 signals. Exclusive adjustable PWTT parameters allows user to improve the blood pressure measurement algorithm effectively. Test parameters can be saved and loaded as a series of customized test sequences to decrease labor time and prevent from human negligence. Raw-data playback reproduces and repeats precious recorded waveforms from clinical trials in a easy way. AECG Assistant software pack helps user to proceed IEC and YY standard tests by clicking a few mouse clicks. Software Development Kit (SDK) allows user to develop customized and automatic test program with less efforts.

41 We Simplify and Explain the Procedures to Save Your Time AECG100 Test System AECG100 Green LED PPG Module AECG100 ECG Module Built-in photodiode and green LED Photodiode detects DUT's LED brightness and behaviors Green LED simulates PPG heart rate signals with various parameters AECG100 Red and IR LED PPG Module Built-in photodiode, Red LED and IR LED Photodiode detects DUT's LED brightness and behaviors Red LED and IR LED simulates SpO2 signals with various parameters ECG Test Mode Adjustable test parameters and various waveforms are designed to meet the requirements of IEC and China YY0885 medical standards USB Connection Pulse Wave Transit Time Test Mode Output ECG and PPG analog signals simultaneously Time difference between ECG and PPG waveforms can be adjustable. USB Connection 39

42 We Simplify and Explain the Procedures to Save Your Time Reflective SpO2 Test Mode SpO2 test mode is only available when connecting with R/IR PPG module Adjustable AC, DC and PI values in both channels User can import and play programmed R-curve USB Connection PPG Heart Rate Test Mode Adjustable PPG waveforms and parameters Offer basic waveforms and simulated noise signals USB Connection Auto-sequence Test Mode Program a test of selected test items in preferred sequence and duration time. Simply click Play button to proceed required tests USB Connection 40

43 We Simplify and Explain the Procedures to Save Your Time AECG Assistant Software Simplify medical standards into parameters and selectable options. Simply click to proceed the required test with confidence. Software Development Kit All test parameters correspond to specific SDK commands Allow PC to communicate with DUT and receive raw data from DUT through SDK and USB connection User can develop automatic testing software to control AECG100 and DUT DLL(Dynamic-link library) shared library supported for efficient program binding and version upgrade Support C/C++ header and C# interface 41

44 42 ECG Medical Standard Cross-reference Table

45 The Accurate and Compliant Test Solution Provider 43

46 We Simplify and Explain the Procedures to Save Your Time IEC :2011 (DIAGNOSTIC ECG) Test Clause SECG 4.0 MECG 2.0 CMRR 3.0 CDCA Requirements for amplitude measurements O O Requirements for absolute interval and wave duration measurements O O Requirements for interval measurements on biological ECGS O O Indication of inoperable ELECTROCARDIOGRAPH O Goldberger and Wilson LEADS O O Recovery time O Input impedance O COMMON MODE REJECTION O Overload tolerance O FILTERS (including line frequency interference FILTERS) O NOISE level O CHANNEL crosstalk O High frequency response O Low frequency (impulse) response O Test with calibration ECGS O Linearity and dynamic range O Recording speed O Use with cardiac pacemakers O IEC :2011, 3RD EDITION (MONITORING ECG) Test Clause SECG 4.0 CMRR Accuracy of signal reproduction O Input dynamic range and differential offset voltage O Input impedance O Input NOISE O Multichannel crosstalk O GAIN control and stability O Sweep speed O Frequency and impulse response O GAIN INDICATOR O Common mode rejection O Baseline reset O Pacemaker pulse display capability O Rejection of pacemaker pulses O Synchronizing pulse for cardioversion O Heart rate range, accuracy, and QRS detection range O Channel height and aspect ratio O Tall T-wave rejection capability O 44

47 We Simplify and Explain the Procedures to Save Your Time IEC :2012 (AMBULATORY ECG) Test Clause SECG 4.0 MECG 2.0 CMRR 3.0 RDCA The accuracy of QRS detection O The accuracy of heart rate measurements O The accuracy of VEB detection O Claime to detect ventricular flutter or fibrillation (VF) O Claimed to detect supraventricular ectopic beats, or atrial flutter or fibrillation (AF), claimed to measure ST SEGMENT deviations or to detect ST SEGMENT changes O Required statistics O Requirements for all arrhythmia algorithms O Requirements for algorithms with optional capabilities O Simulated test patterns O Use of standard databases O O Use of annotation files O Beat-by-beat comparison O General description O Method for beat-by-beat comparison O Heart rate, and heart rate or RR interval variability O Heart rate measurement O Heart rate variability or RR interval variability measurement test Patterns O Run-by-run comparison O General description O Terms and symbols O Run sensitivity summary matrix O Run positive predictivity summary matrix O VF and AF comparisons O Physician report minimum requirements O Heart rate O Supraventricular ectopy O Ventricular ectopy O Bradycardia data O PAUSES O ST SEGMENT shifts O ECG hard copy O Incorrect output O Linearity and dynamic range O Input impedance O Common mode rejection O GAIN accuracy O GAIN stability O System noise O Multichannel crosstalk O Frequency response O Function in the presence of pacemaker pulses O Timing accuracy O GAIN settings and switching O Temporal alignment O 45

48 We Simplify and Explain the Procedures to Save Your Time YY 记录和分析型单道和多道心电图机 Test Clause SECG 4.0 MECG 2.0 CMRR 3.0 CDCA 心电图的自动量测 O 用来评估心电图自动测量准确性的标准数据库 O 振幅测量的要求 O 绝对间期和波形时限测量的要求 O 50 工作數據的準確性 实际人体心电图时限测量的要求 O 抗噪声测量稳定性的公布要求 O 心电图的自动解释 O 衡量心电图自动诊断准确度指标的定义 O 公开预期用途 O 形态诊断用心电图数据库 O 公开解释诊断准确性的要求 O 节律诊断用心电图数据库 O 公开节律诊断准确性的要求 O Goldberger 及 Wilson 导联 O O 恢复时间 O 输入阻抗和导联网络阻抗 O 灵敏度的稳定性 O 灵敏度的精确度 O 共模抑制 O 过载容限 O 51 危险输出的防护 基线 : 噪声电平 O 描记速度与轨迹宽度 O 多道心电图机的道间干扰 O 高频响应 O 低频 ( 脉冲 ) 响应 O 线性和动态范围 O 最小信号响应 O 直角坐标, 描记点的对齐 O 记录速度 O 在有心脏起搏器的情况下使用 心电波形失真 O 在有心脏起搏器的情况下使用 起搏脉冲的可见性 O 46

49 We Simplify and Explain the Procedures to Save Your Time YY (IEC : 2001) 动态心电图机 Test Clause SECG 4.0 MECG 2.0 CMRR 3.0 CDCA 自动分析 O 用于评估自动分析的标准数据库 O O 性能报告要求 O 用于性能测试的标准数据库 O O 50 工作数据的准确性 记录比对结果 O 统计 O 测试方法 O 心率 O 室上性异位 O 心室异位 O 心动过缓数据 O 停搏 O ST 段偏移 O ECG 备份 O 动态输入范围 O 输入阻抗 O 共模抑制 O 增益准确度 O 51 危险输出的防护 增益稳定性 O 定标信号 O 系统噪声 O 道间干扰 O 频率响应 O 最小检测信号 O 起搏脉冲显示能力 O 时间轴对齐 O 47

50 We Simplify and Explain the Procedures to Save Your Time YY (ANSI/AAMI EC13: 2002) 心电监护仪 Test Clause SECG 4.0 CMRR c) 高大 T 波的抑制能力 O e) 心率计准确度和对心律不齐的响应 O f) 心率计对心率变化的响应时间 O g) 心动过速报警的启动时间 O 起搏器脉冲抑制能力 O 起搏脉冲检测器对快速心电图信号的抑制 O 过载保护 O QRS 波幅度和宽度范围 O 工频电压容差 O 漂移容差 O 心率计的范围和准确度 O 报警限误差 O 心动停止报警的启动时间 O 心率低报警的启动时间 O 心率高报警的启动时间 O 报警静音 O 输入动态范围 O 输入阻抗 O 系统噪声 O 多通道串扰 O 增益控制和稳定性 O 时间基准选择和准确度 O 输出显示 O 输入信号重建准确度 O 定标电压 O 共模抑制 O 基线控制和稳定度 O 起搏脉冲显示能力 O 48

51 We Simplify and Explain the Procedures to Save Your Time YY (ANSI/AAMI EC11:1991) 心电诊断设备 Test Clause SECG 4.0 CMRR 输入动态范围 O 增益设置和准确度 O 增益稳定性 O 时间基准选择和准确度 O 轨迹宽度和可视性 O 直角坐标 / 记录点对齐 O 系统误差 O 频率和脉冲响应 O 导联权重因子 O 滞后 O 定标电压 O 输入阻抗 O 共模抑制 O 电缆, 电路和输出显示噪声 O 多通道串扰 O 基线控制和稳定度 : 复位 O 过载保护 : 交流电压 O 起搏脉冲显示能力 O 49

52 We Simplify and Explain the Procedures to Save Your Time JJG 心电监护仪 Test Clause SECG 4.0 CMRR 电压测量误差的检定 步进增益转换式 O 电压测量误差的检定 连续可调增益转换式 O 极化电压引起的电压测量偏差的检定 O 噪声电平的检定 O 扫瞄速度误差的检定 O 监护导联幅频特性的检定 O 标准心电导联幅频特性的检定 O 共模抑制比的检定 O 心率显示值误差的检定 O 心率显报警发生时间检定 O 心率报警预置值的检定 O 电压测量误差的检定 步进增益转换式 ( 描笔式心电图记录部分 ) O 电压测量误差的检定 连续可调增益转换式 ( 描笔式心电图记录部分 ) O 记录速度误差的检定 ( 描笔式心电图记录部分 ) O 时间常数的检定 ( 描笔式心电图记录部分 ) O 滞后 ( 描笔式心电图记录部分 ) O 监护导联幅频特性的检定 ( 描笔式心电图记录部分 ) O 标准心电导联幅频特性的检定 ( 描笔式心电图记录部分 ) O 移位非线性偏差的检定 O 基线漂移的检定 O 共模抑制比的检定 O 50

53 We Simplify and Explain the Procedures to Save Your Time JJG 数字心电图机 Test Clause SECG 4.0 CMRR 内定标电压误差 O 4.2 输入电压范围 O 4.3 耐极化电压 O 4.4 加权系数误差 O 4.5 内部噪声电平 O 4.6 波形识别能力与幅度 - 时间参数测量 O 4.7 幅频特性 O 4.8 时间常数 O 4.9 心率测量误差 O 4.10 共模抑制比 O JJG 动态 ( 可移动 ) 心电图机 Test Clause SECG 4.0 CMRR 最大输入范围 O 4.2 最小描记灵敏阈 O 4.3 耐极化电压 O 4.4 输入阻抗 O 4.5 灵敏度误差 O 4.6 灵敏度稳定度 O 4.7 定标电压 O 4.8 频率响应 O 4.9 过冲 O 4.1 滞后 O 4.12 硬拷贝描记速度误差 O 4.13 道间串扰 O 4.14 共模抑制比 O 4.15 系统噪声电平 O 4.16 起搏脉冲顺应性及检测能力 O 51

54 Made for the Industry Leading Technology Globally-recognized Profession Experienced Team 52

55 53

56 9F, No.27, Minquan W. Rd., Zhongshan Dist., Taipei City 10452, Taiwan PC_EN_ Rev 1.1

ECG Set. We Simplify the Procedures and You Save Time!

ECG Set. We Simplify the Procedures and You Save Time! ECG Set We Simplify the Procedures and You Save Time! WhaleTeq ECG Set Standard coverage: IEC 6060--5, --7, --47, AAMI/ANSI EC, EC, EC8, EC57, YY079, YY9, YY078, etc. Adopted by International Certification

More information

3-Channel Constant Current LED Driver UCS1903

3-Channel Constant Current LED Driver UCS1903 3-Channel Constant Current LED Driver UCS1903 (Products descriptions) The product UCS1903 is the three-channel LED drive control circuit, internal integration MCU digital interface, data latches, LED high

More information

Electrical Engineering

Electrical Engineering Electrical Engineering Educational Objectives This major aims to cultivate well-grounded, practical, creative and all-round research talents who are well developed in morality, intelligence and physical

More information

YP G-HSD Hall Current Sensor 确保测量准确精度高 安装方便 售价低. 执行标准 Standard 过载能力 Overload 精度 Accuracy 线性度 Linearity 失调电压 Voltage maladjustment

YP G-HSD Hall Current Sensor 确保测量准确精度高 安装方便 售价低. 执行标准 Standard 过载能力 Overload 精度 Accuracy 线性度 Linearity 失调电压 Voltage maladjustment YPG-HSD YP G-HSD Hall Current Sensor Model Description YPG - HSD - 外形代号 (Externality Code) - 额定电流 (Rated Current) HSD 外形代号 Externality Code 霍尔效应直检式传感器 Hall Effect Current Sensor & Transducer 1~7 ( 见外形图

More information

YDS Presentation. KRL series for Inverter Air-con 横浜電子精工株式会社

YDS Presentation. KRL series for Inverter Air-con 横浜電子精工株式会社 YDS Presentation KRL series for Inverter Air-con 2014 横浜電子精工株式会社 CORPORATE PROFILE Company Name Co.,Ltd Date of Establishment Nov. 1940 YDS ( 横浜電子精工株式会社 ) Business Focus Thin Film Resistor Head Office

More information

Big Data and High Performance Computing

Big Data and High Performance Computing Big Data and High Performance Computing Big data and high performance computing focus on academic research and technology development in areas of high performance computing platform architecture, parallel

More information

SPECIFICATION. 宁波凯普电子有限公司 Ningbo Kepo Electronics Co.,Ltd.

SPECIFICATION. 宁波凯普电子有限公司 Ningbo Kepo Electronics Co.,Ltd. SPECIFICATION Customer : Lomex Applied To : Product Name : Piezo Buzzer Model Name : KPI-G1410C-K9059 : 受 控 Compliance with ROHS( 本品符合 ROHS 指令 ) Signature of Approval Signature of KEPO Approved by Checked

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL FOR APPROVAL CUSTOMER : 01097 REV.00 ARTICLE: STANDARD : UL/GS/CE/SAA 桌面式 MODEL NO. : DYS40-240166W OUR PART NO.: DYS40-240166-16922 YOUR PART NO.: INPUT : 100-240V AC 50/60Hz OUTPUT: 24.0V DC 1.66A 供应商确认

More information

IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达

IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达 IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达 compact package matching most existing motors 100~120Vac Single Phase Power Input Opto-isolated inputs and outputs uto-current down feature Half

More information

JCS1404 封装 Package. High efficiency switch mode power supplies UPS

JCS1404 封装 Package. High efficiency switch mode power supplies UPS 主要参数 MAIN CHAACTEISTICS 封装 Package N 沟道增强型场效应晶体管 N-CHANNEL MOSFET ID VDSS dson-max (@Vgs=10V) Qg-typ 用途 高频开关电源 UPS 电源 204 A 40 V 4 mω 106nC APPLICATIONS High efficiency switch mode power supplies UPS 产品特性

More information

EMF Safety and Actions in China Telecom

EMF Safety and Actions in China Telecom 4 th ITU Green Standards Week EMF Safety and Actions in China Telecom Tan Rumeng China Telecommunications Corp. 25 September 2014 Outline 31 Background 2 EMF safety in China 3 EMF actions in China Telecom

More information

FTP10N40/FTA10N40 400V N 沟道 MOS 场效应管. 产品特点 低的导通电阻 低的栅极电荷 ( 典型值为 34nC) 开关速度快 100% 雪崩测试 符合 RoHS 标准 / 无铅封装 产品应用 高效开关电源 适配器 / 充电器 有源功率因数校正 液晶面板电源 订购代码

FTP10N40/FTA10N40 400V N 沟道 MOS 场效应管. 产品特点 低的导通电阻 低的栅极电荷 ( 典型值为 34nC) 开关速度快 100% 雪崩测试 符合 RoHS 标准 / 无铅封装 产品应用 高效开关电源 适配器 / 充电器 有源功率因数校正 液晶面板电源 订购代码 400V N 沟道 MOS 场效应管 产品特点 低的导通电阻 低的栅极电荷 ( 典型值为 34nC) 开关速度快 00% 雪崩测试 符合 RoHS 标准 / 无铅封装 BV DSS R DS(ON) (Max.) I D 400V 0.50Ω 0A 产品应用 高效开关电源 适配器 / 充电器 有源功率因数校正 液晶面板电源 订购代码 器件型号封装形式标识 FTP0N40 TO-220 FTP0N40

More information

3DD13005ED 主要参数 MAIN CHARACTERISTICS

3DD13005ED 主要参数 MAIN CHARACTERISTICS 主要参数 MAIN CHAACTEISTICS I C V CEO P C (IPAK/126/126S/220HF) P C (DPAK/TO-252) P C (TO-220C/262/263) NPN 型高压功率开关晶体管 HIGH VOLTAGE FAST-SWITCHING NPN POWE TANSISTO 4A 400V 40W 50W 75W 用途 节能灯 电子镇流器 高频开关电源

More information

WHALETEQ Common Mode Rejection Ratio Tester (CMRR 3.0) User Manual (Revision )

WHALETEQ Common Mode Rejection Ratio Tester (CMRR 3.0) User Manual (Revision ) WHALETEQ Common Mode Rejection Ratio Tester (CMRR 3.0) User Manual (Revision 2017-10-06) Copyright (c) 2013-2017, All Rights Reserved. WhaleTeq Co. LTD No part of this publication may be reproduced, transmitted,

More information

NX70 Installation Instructions High Speed Counter Module

NX70 Installation Instructions High Speed Counter Module Maximum Value for OEMs SM NX70 Installation Instructions High Speed Counter Module Catalog Number: NX70-HSC1, NX70-HSC2 Contents English... 3 Chinese... 23 English Contents Important User Information...4

More information

Multi-Channel CMOS Front-End IC for Physiological Signal Acquisition 生理信号采集的多通道 CMOS 模拟前端集成电路设计 张金勇王磊于力

Multi-Channel CMOS Front-End IC for Physiological Signal Acquisition 生理信号采集的多通道 CMOS 模拟前端集成电路设计 张金勇王磊于力 Vol 3 No9 / Sep 29 CMOS Front-End IC for Physiological Signal Acquisition 生理信号采集的多通道 CMOS 模拟前端集成电路设计 张金勇王磊于力 ABSTRACT A compacted and low-offset multi-channel CMOS front-end IC for physiological signal

More information

RHT03-SPI Temperature & Humidity Sensor

RHT03-SPI Temperature & Humidity Sensor - Relative humidity and temperature sensor - 相对温度和湿度传感器 - Pre-calculated temperature and humidity read out, no extra calculation needed - 预先计算的温度和湿度读出, 无需额外计算 - Dew Point Calculation possible - 可以计算露点

More information

A Self-Adaptive Low-Voltage Current Mode ASK Demodulator for RFID Tags

A Self-Adaptive Low-Voltage Current Mode ASK Demodulator for RFID Tags A Self-Adaptive Low-Voltage Current Mode ASK Demodulator for RFID Tags Wei Liu, Yongming Li, Chun Zhang, Zhihua Wang Tsinghua National Laboratory for Information Science and Technology Institute of Microelectronics,

More information

WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x

WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x (Revision 2017-02-13) Contents 1 Introduction... 4 1.1 Basic concept... 4 1.2 Standards/Application... 5 1.3

More information

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual WHALETEQ ESU Neutral Electrodes Impedance Tester Model: HFPA150 User Manual Version2014-10-30 Hardware Version1.3.x 1. Introduction HFPA150 is a unique tester specifically designed for the testing of neutral

More information

产品规格书 金龙机电股份有限公司 JINLONG MACHINERY & ELECTRONIC CO., LTD. PRODUCT SPECIFICATION. 客户名称 / Buyer Name 客户信息. 客户料号 /Buyer s Part No.

产品规格书 金龙机电股份有限公司 JINLONG MACHINERY & ELECTRONIC CO., LTD. PRODUCT SPECIFICATION. 客户名称 / Buyer Name 客户信息. 客户料号 /Buyer s Part No. 金龙机电股份有限公司 JINLONG MACHINERY & ELECTRONIC CO., LTD. 产品规格书 PRODUCT SPECIFICATION 客户信息 客户名称 / Buyer Name 客户料号 /Buyer s Part No. 客户承认签章 /Buyer s Approval & Signatures 金龙公司 文件编号 /Spec No. KOTL-G-B003 版本 :A/0

More information

3DD4243D. 封装 Package IPAK

3DD4243D. 封装 Package IPAK 主要参数 MAIN CHAACTEISTICS I C 2.0A V CEO 400V P C (TO-92/TO-92-F1) 1W P C (IPAK/DPAK) P C (TO-126(S)) P C (TO-220) 用途 节能灯 电子镇流器 高频开关电源 高频功率变换 一般功率放大电路 产品特性 高耐压 高电流容量 高开关速度 高可靠性 环保 (ohs) 产品 10W 20W 40W HIGH

More information

M030 and M040. Operating Manual Genelec M030 and M040 Active Monitoring Loudspeakers 操作手册

M030 and M040. Operating Manual Genelec M030 and M040 Active Monitoring Loudspeakers 操作手册 M030 and M040 Operating Manual Genelec M030 and M040 ctive Monitoring Loudspeakers 操作手册 Quick setup guide 快速设置指南 M030 / M040 Speaker Placement 音箱的摆放 Vertical ngle 垂直方向的角度 L 30 C R L C R 110 LS RS RS LS

More information

NX70 Installation Instructions High Performance Pulse Output Counter Module

NX70 Installation Instructions High Performance Pulse Output Counter Module Maximum Value for OEMs SM NX70 Installation Instructions High Performance Pulse Output Counter Module Catalog Number: NX70-PULSE4 Contents English... 3 Chinese... 19 English Contents Important User Information...4

More information

WiMAX 技术培训系列 ( 一 ) OFDM 物理层技术初探 MCG 赵昕 2006 年 2 月. All rights reserved 2006, Alcatel Shanghai Bell

WiMAX 技术培训系列 ( 一 ) OFDM 物理层技术初探 MCG 赵昕 2006 年 2 月. All rights reserved 2006, Alcatel Shanghai Bell WiMAX 技术培训系列 ( 一 ) OFDM 物理层技术初探 MCG 赵昕 2006 年 2 月 目录 Page 2 一. 为什么出现 WiMAX? 二. 什么是 WiMAX? 三. 什么是 OFDM/OFDMA? 四.WiMAX 的 PHY 层五.WiMAX 接入过程 Page 3 一. 为什么出现 WiMAX? 一. 为什么出现 WiMAX? 移动通信的发展过程正在从 3Any 向 Olympics

More information

MEDTEQ Single Channel ECG System 3.0. Operation Manual

MEDTEQ Single Channel ECG System 3.0. Operation Manual MEDTEQ Single Channel ECG System 3.0 Operation Manual Revision 2010-10-04 Blank page Contents 1 Introduction... 4 1.1 Basic concept... 4 1.2 Standards... 5 1.3 Block diagram / USB Module overview... 6

More information

¼'' TS 法律声明 10. MUSIC Tribe

¼'' TS 法律声明 10. MUSIC Tribe NEUTRON Paraphonic Analog and Semi-Modular Synthesizer with Dual 3340 VCOs, Multi-Mode VCF, 2 ADSRs, BBD Delay and Overdrive Circuit in a Eurorack Format 2 NEUTRON 快速启动向导 3 重要的安全须知 ¼'' TS 1. 2. 3. 4. 5.

More information

SVPWM 三相电压源型逆变器的死区时间效应可能会导致电压损失, 电流波形畸变和转矩脉动. 为了改善电流波形, 减少转矩脉动, 详细分析了死区时间对输出电压的影响, 并提出了 SVPWM A

SVPWM 三相电压源型逆变器的死区时间效应可能会导致电压损失, 电流波形畸变和转矩脉动. 为了改善电流波形, 减少转矩脉动, 详细分析了死区时间对输出电压的影响, 并提出了 SVPWM A 18 1 2013 2 Vol 18 No 1 JOURNAL OF HARBIN UNIVERSITY OF SCIENCE AND TECHNOLOGY Feb 2013 SVPWM 150050 三相电压源型逆变器的死区时间效应可能会导致电压损失, 电流波形畸变和转矩脉动 为了改善电流波形, 减少转矩脉动, 详细分析了死区时间对输出电压的影响, 并提出了 SVPWM 死区时间的补偿方法 该方法通过改变传统的

More information

A2 产品技术规格书 深圳市爱普泰科电子有限公司 ABTEC-A2 音频测试分析仪 前面板图 后面板图 ABTEC-WI099-A0 产品 型号 产品 功能 产品 版本 V1.0 产品 外观

A2 产品技术规格书 深圳市爱普泰科电子有限公司 ABTEC-A2 音频测试分析仪 前面板图 后面板图 ABTEC-WI099-A0 产品 型号 产品 功能 产品 版本 V1.0 产品 外观 深圳市爱普泰科电子有限公司 T:0755-8638 0078 E:sales@szaptk.com www.szaptk.com 地址 : 深圳市龙华观澜大富工业区 20 号硅谷动力智能终端产业园 A4 栋 5 楼 产品技术规格书 ABTEC-WI099-A0 产品 型号 ABTEC- 产品 功能 音频测试分析仪 产品 版本 V1.0 前面板图 产品 外观 后面板图 2014.03.22 序号 NO.

More information

1 BGJ 型变频调速纵剪线 ( 液压 ) FOB60000 USD/SET. BGJ variable frequency speed regulating slitting line (hydraulic pressure)

1 BGJ 型变频调速纵剪线 ( 液压 ) FOB60000 USD/SET. BGJ variable frequency speed regulating slitting line (hydraulic pressure) 1 BGJ1250-06 型变频调速纵剪线 ( 液压 ) FOB60000 USD/SET BGJ1250-06 variable frequency speed regulating slitting line (hydraulic pressure) 1 滚剪切硅钢片或低碳钢薄板厚度 : 0.2~0.5mm Thickness of roll slitting silicon steel sheet

More information

Ultrasonic thickness measurement for aluminum alloy irregular surface parts based on spectral analysis

Ultrasonic thickness measurement for aluminum alloy irregular surface parts based on spectral analysis Trans. Nonferrous Met. Soc. China 22(2012) s323 s328 Ultrasonic thickness measurement for aluminum alloy irregular surface parts based on spectral analysis CONG Sen, GANG Tie State Key Laboratory of Advanced

More information

GAMI Newsletter. Foreword. News. News Industry Projects Training Events Contact. News Industry Projects Training Events Contact

GAMI Newsletter. Foreword. News. News Industry Projects Training Events Contact. News Industry Projects Training Events Contact Foreword Dear Partners and Friends, The Global Advanced Manufacturing Institute is aiming at implementing Operational Excellence to manufacturing companies in China. During the first quarter of 2016, we

More information

Brief Introduction to Degree Program in Control. Science and Engineering (0811)

Brief Introduction to Degree Program in Control. Science and Engineering (0811) Brief Introduction to Degree Program in Control Science and Engineering (0811) I. Brief Introduction to the Discipline 1. Orientation and Goal Southwest Jiaotong University (SWJTU) is one of the oldest

More information

Analog Applications 模拟应用期刊 Journal

Analog Applications 模拟应用期刊 Journal Analog Applications 模拟应用期刊 Journal Second 015 年第 Quarter 季度 015 Copyright 015 Texas 德州仪器 Instruments 015 年版权所有 Incorporated. All rights reserved. Analog Applications Journal 模拟应用期刊 Contents 目录 引言 Introduction......3

More information

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

型号 :ZLE12864B-FFSSWE-NAA

型号 :ZLE12864B-FFSSWE-NAA 修改记录 版本号 :. 型号 :ZLE2864B-FFSSWE-NAA 版本号 日期 PAGE 内容. 28-9-9 NEW RELEASE ================================================================== ZLE2864B 28X64 DOTS GRAPHICS MODULE PAGE: OF29 LCD MODULE NUMBERING

More information

Single Channel EEG Test System User Manual WHALETEQ. Single Channel EEG Test System (SEEG 100) User Manual

Single Channel EEG Test System User Manual WHALETEQ. Single Channel EEG Test System (SEEG 100) User Manual WHALETEQ Single Channel EEG Test System (SEEG 100) User Manual 2018-07-18 Contents 1 Introduction... 3 1.1 Basic concept... 3 1.2 Standards/Application...4 1.3 Block diagram/seeg 100 Module overview...

More information

SOLIDWORKS D CAD Matrix

SOLIDWORKS D CAD Matrix SOLIDWORKS 2018 3D CAD Matrix SOLIDWORKS Premium SOLIDWORKS Professional SOLIDWORKS Standard The premier package for CAD professionals Maximize your design productivity Get started in 3D CAD design Ease

More information

Lecture 19. Ultrasound Imaging

Lecture 19. Ultrasound Imaging Lecture 19 Ultrasound Imaging Contents 1. Introduction 2. Ultrasound and its generation 3. Wave propagation in the matter 4. Data acquisition (A, B, M and Doppler model) 5. Imaging reconstruction (5 steps)

More information

Chapter 3. Cellular Concept

Chapter 3. Cellular Concept Chapter 3 Cellular Concept Contents 3.1 Introduction 3.2 Frequency Reuse 3.3 Channel Assignment Strategies 3.4 Handoff Strategies 3.5 Interference and System Capacity 3.6 Trunking and Grade of Service

More information

Version:2.0 M1+/M2/M3

Version:2.0 M1+/M2/M3 Version:2.0 M1+/M2/M3 Safety Information CAUTION: To reduce the risk of electric shock, do not remove any cover(or the rear section). No user serviceable parts inside. Refer servicing to qualified service

More information

用户手册 HE-XE & HE-XT 100, 102, 103, 104, 105

用户手册 HE-XE & HE-XT 100, 102, 103, 104, 105 用户手册 HE-XE & HE-XT 100, 102, 103, 104, 105 HE-XE220C100/HE-XE220C000, HE-XT220C100/HE-XT220C000 HE-XE220C112 / HE-XE220C01, HE-XT220C112 / HE-XT220C012 HE-XE220C114 / HE-XE220C014, HE-XT220C114 / HE-XT220C014

More information

Long-Awaited Film 期待已久的影片

Long-Awaited Film 期待已久的影片 Long-Awaited Film 期待已久的影片 1 Long-Awaited Film 期待已久的影片 Stars Turn Out for the Premiere in London 明星亮相伦敦首映式 Read the text below and do the activity that follows. 阅读下面的短文, 然后完成练习 : Sex and the City was a

More information

Si720x 霍尔效应磁性开关 / 锁存器位置传感器数据表

Si720x 霍尔效应磁性开关 / 锁存器位置传感器数据表 Si720x 霍尔效应磁性开关 / 锁存器位置传感器数据表 Silicon Labs 提供的 Si7201/2/3/4/5/6 霍尔效应磁性传感器和锁存器产品系列结合了斩波稳定型霍尔元件以及低噪声模拟放大器 13 位 AD 转换器和灵活的比较器电路 借助 Silicon Labs 成熟的 CMOS 设计技术,Si720x 产品系列融入数字信号处理, 为温度和失调漂移提供精密补偿 与现有霍尔效应传感器相比,Si720x

More information

激光焊接装置系列. Laser Welder Series

激光焊接装置系列. Laser Welder Series 激光焊接装置系列 Laser Welder Series Laser Welder Series Avio 激光焊接装置的概要 以多样化的手机等信息终端为代表的电子机器的小型轻量化 高功能化使得这些机器的零部件更加微小 精密和复杂 所以传统的焊接方法难以对应的形状结构 尺寸和材料的焊接需求也日益增加 并且, 对于太阳能电池和充电电池等与能源相关的零部件, 则需要将铜 铝等散热性和导电性强的材料高品质焊接在一起

More information

09-Architecture Design 游戏架构设计. Ref cornell

09-Architecture Design 游戏架构设计. Ref cornell 09-Architecture Design 游戏架构设计 盛斌 Ref cornell Architecture: The Big Picture Architecture: The Big Picture 2 Game Architecture Design Patterns Reusable solution to a reoccurring problem Template, not a single

More information

US SERIES CONNECTOR FOR AUTOMOBILES

US SERIES CONNECTOR FOR AUTOMOBILES US SERIES CONNECTOR FOR AUTOMOBILES Specifications of Terminals 0.64 Inline/ Device mm 2 Applicable wire size(mm 2 ) AWG Cable overall diameter(mm) Applicable tab thickness(mm) Contact resistance initial

More information

WiFi 雷达 无所不在的感知 清华大学软件学院

WiFi 雷达 无所不在的感知 清华大学软件学院 WiFi 雷达 无所不在的感知 杨铮 清华大学软件学院 Outline Introduction Background Methods & Applications Conclusion 2 WiFi Signals Everywhere Visualization of WiFi signals by Luis Hernan 3 WiFi as Radar? WiFi Radar Omnipresent

More information

Operating Instructions 使用说明书. Integrated Stereo Amplifier TA-A1ES

Operating Instructions 使用说明书. Integrated Stereo Amplifier TA-A1ES Operating Instructions 使用说明书 Integrated Stereo Amplifier TA-A1ES WARNING The unit is not disconnected from the mains as long as it is connected to the AC outlet, even if the unit itself has been turned

More information

Mixed Frequency Allocation Strategy for GSM-R

Mixed Frequency Allocation Strategy for GSM-R Mixed Frequency Allocation Strategy for GSM-R Xiao-Li Jiang, Xu Li State Key Laboratory of Rail Traffic Control and Safety (Beijing Jiaotong University), Beijing, 100044, China Abstract: In this paper,

More information

US SEALED SERIES. Structure. Features 特点. Connector M Connector F

US SEALED SERIES. Structure. Features 特点. Connector M Connector F US SEALED SERIES Structure Connector M Connector F Features 特点 Housing Housing TPA TPA Terminal Terminal Wire Seal Wire Seal US sealed series comply with SAE/USCAR-2. This series consits of 0.64mm, 1.5mm,

More information

Chapter 6 Basics of Digital Audio

Chapter 6 Basics of Digital Audio Chapter 6 Basics of Digital Audio 6.1 Digitization of Sound 6.2 MIDI: Musical Instrument Digital Interface 6.3 Quantization and Transmission of Audio 6.3 Quantization and Transmission of Audio Coding of

More information

Automated impact device with non-synchronous impacts: a practical solution for modal testing during operation *

Automated impact device with non-synchronous impacts: a practical solution for modal testing during operation * 452 Ong et al. / J Zhejiang Univ-Sci A (Appl Phys & Eng) 208 9(6):452-460 Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering) ISSN 673-565X (Print); ISSN 862-775 (Online) www.jzus.zju.edu.cn;

More information

NC HVVF. Product Features. Product introduction. Partial voltage frequency converter products. Remarkable performance features

NC HVVF. Product Features. Product introduction. Partial voltage frequency converter products. Remarkable performance features NC HVVF Product introduction NC HVVF, integrating with the advanced power electronics technologies of the world, is a IGBT HVC independently developed by Nancal Energy-Saving Technology Co., Ltd.. PW control

More information

1 st 5G Algorithm Competition SCMA

1 st 5G Algorithm Competition SCMA 1 st 5G Algorithm Competition SCMA Task Description Requirements 要求 : SCMA 下一代无线通信的稀疏码多址接入 多址接入是无线通信物理层最核心的技术之一, 它使得无线基站能区分并同时服务多个终端用户 现有系统采用正交的多址接入方式, 即多个用户通过在不同维度上 ( 频分 时分 码分等 ) 正交划分的资源来接入, 现在 4G 系统中采用的

More information

Game playing. Chapter 6

Game playing. Chapter 6 Game playing Chapter 6 Game Playing Game playing was thought to be a good problem for AI research: game playing is non-trivial players need human-like intelligence games can be very complex (e.g., Chess,

More information

Slicing of Aspect-Oriented Programs Based on Reduced Dynamic Dependence Graph *

Slicing of Aspect-Oriented Programs Based on Reduced Dynamic Dependence Graph * ISSN 1673-9418 CODEN JKYTA8 E-mail: fcst@vip.163.com Journal of Frontiers of Computer Science and Technology http://www.ceaj.org 1673-9418/2011/05(03)-0229-09 Tel: +86-10-51616056 DOI: 10.3778/j.issn.1673-9418.2011.03.004

More information

LED Architect WEBENCH. 项目报告项目 : /2 : Project ID 2 项目概览总 BOM 成本 : $0.00

LED Architect WEBENCH. 项目报告项目 : /2 : Project ID 2 项目概览总 BOM 成本 : $0.00 WEBENCH LED Architect Project ID : 2 Project ID 2 LED Architect 2013-05- 13 18:52:39.413 Vsource 180V - 250V Driver_1 LM3464 15.41V, 0.7A Load #1 WEBENCH LED Architect 项目报告项目 : 3715830/2 : Project ID 2

More information

SF112A SF115A 12 2-way Active Sound Reinforcement Loudspeaker 15 2-way Active Sound Reinforcement Loudspeaker

SF112A SF115A 12 2-way Active Sound Reinforcement Loudspeaker 15 2-way Active Sound Reinforcement Loudspeaker 12 2-way Active Sound Reinforcement Loudspeaker 15 2-way Active Sound Reinforcement Loudspeaker Live Sound, Speech, Playback, DJ, A/V, Institutional Venues General Description The and are 2-way powerful

More information

Table of Contents. DS177-ZH LUXEON V2 Product Datasheet Lumileds Holding B.V. All rights reserved.

Table of Contents. DS177-ZH LUXEON V2 Product Datasheet Lumileds Holding B.V. All rights reserved. Illumination LUXEON V2 卓越性能 更多可用光 久经验证的封装 设计 LUXEON V2 是一种基于芯片级封装 (CSP 的高功率圆顶 LED 针对定向应用 进行了优化 传承了 Lumileds 在同类产品中的领先地位 LUXEON V2 具备 优越的效能和稳健性 采用 3 条式 3535 封装 可通过与 LUXEON TX 辐射模 式相匹配加快产品的上市时间 同时通过在更高驱动电流下提供无与伦比的

More information

Product Specification

Product Specification Product Specification Product Name: 120W micro infrared remote control LED driver LDP-120M170 Product Model: LDP-120R170 Rev. A.1 CE CE Address: Sangtai Industrial Park Guanwai Xiaobaimang Songbai Road

More information

Dual-channel, 120MHz maximum bandwidth, 20Vpp maximum output amplitude, high fidelity output with 80dB dynamic range

Dual-channel, 120MHz maximum bandwidth, 20Vpp maximum output amplitude, high fidelity output with 80dB dynamic range SDG2000X Series Function/Arbitrary Waveform Generator Key Features Dual-channel, 120MHz maximum bandwidth, 20Vpp maximum output amplitude, high fidelity output with 80dB dynamic range High-performance

More information

Qualanod Specifications Qualanod 2017 版标准. QUALISINO AGM, Foshan, Josef Schoppig Secretary General

Qualanod Specifications Qualanod 2017 版标准. QUALISINO AGM, Foshan, Josef Schoppig Secretary General Qualanod - 2017 Specifications Qualanod 2017 版标准 QUALISINO AGM, Foshan, 25.07.18 Josef Schoppig Secretary General Fore-runner of Qualanod Qualanod 的前生 1969 The EWAA quality label for anodized aluminium

More information

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2. EJX / EJA-E series Change No. 15-013 For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2. 1. Applicable Users and Page IM No.

More information

GSM/GPRS. By Mendy Ouzillou Silicon Laboratories Inc. Austin, TX GSM 3GPP (GSM) burst current) GSM900 DCS V

GSM/GPRS. By Mendy Ouzillou Silicon Laboratories Inc. Austin, TX GSM 3GPP (GSM) burst current) GSM900 DCS V GSM/GPRS By Mendy Ouzillou Silicon Laboratories Inc. Austin, TX GSM Q ( ) 3GPP (GSM) burst current) GSM900 DCS1800 50 Ω 3.5 V 25 3.7 V www.silabs.com/pa-calculations 32.75 (GSM) dbm (DCS) 29.75 dbm 1-3)

More information

IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others

IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER INTRODUCTION 25 reasons to differentiate Impulse 6000D/7000DP from all others Function 1. Compatible with full range of defibrillation technologies

More information

SDG2000X Series Function/Arbitrary Waveform Generator. DataSheet

SDG2000X Series Function/Arbitrary Waveform Generator. DataSheet SDG2000X Series Function/Arbitrary Waveform Generator DataSheet-2015.7 Key Features SDG2122X SDG2082X SDG2042X Overview SIGLENT s SDG2000X is a series of dual-channel function/arbitrary waveform generators

More information

For Steel Cutting P Series Chipbreakers

For Steel Cutting P Series Chipbreakers 钢加工用智能断屑槽 Chipbreaker for Steel Cutting 系列 钢加工用 智能断屑槽 系列 For Steel Cutting P Series Chipbreakers 用 PG 断屑槽登场! 完成钢加工用智能断屑槽 /PQ/PG 三重奏! PG chipbreaker for medium and rough turning newly added to the P series

More information

The Simulation Research of the reamer of the cutter suction. dredger based on ADAMS

The Simulation Research of the reamer of the cutter suction. dredger based on ADAMS International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 30-9364, ISSN (Print): 30-9356 Volume 3 Issue 1 ǁ December. 015 ǁ PP.07-13 The Simulation Research of the reamer of the

More information

SDG2000X Series Function/Arbitrary Waveform Generator. DataSheet

SDG2000X Series Function/Arbitrary Waveform Generator. DataSheet SDG2000X Series Function/Arbitrary Waveform Generator DataSheet-2017.05 Key Features SDG2122X SDG2082X SDG2042X Overview SIGLENT s SDG2000X is a series of dual-channel function/arbitrary waveform generators

More information

National Standard of the People's Republic of China 中华人民共和国国家标准

National Standard of the People's Republic of China 中华人民共和国国家标准 UDC GB National Standard of the People's Republic of China 中华人民共和国国家标准 P GB/T 50062 2008 Code for Design of Relaying Protection and Automatic Device of Electric Power Installations 电力装置的继电保护和自动装置设计规范 Issued

More information

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual medlab Three Lead ECG OEM board EG01010 Technical Manual Copyright Medlab 2008-2016 Version 1.03 1 Version 1.03 28.04.2016 Medlab GmbH Three Lead

More information

MBD for ANSYS Simulation

MBD for ANSYS Simulation MBD for ANSYS Simulation 焦晓娟 / 高级工程师 13127889362 2015 ANSYS, Inc. 1 Why do MBD simulation? OutLine The difference between MBD and FEA for Dynamics simulation How do MBD simulation? What is MBD for ANSYS?

More information

深圳市神牛摄影器材有限公司 Instruction Manual

深圳市神牛摄影器材有限公司 Instruction Manual 深圳市神牛摄影器材有限公司 GODOX Photo Equipment Co., Ltd. 地址 /Add: 深圳市宝安区福永镇福海大道西新和村华发工业园 A4 栋 2/F, Building A4, Xinhe Huafa Industrial Zone, Fuhai RD West, Fuyong Town, Baoan District, Shenzhen 518103, China 电话 /Tel:

More information

SMART Manufacturing Technologies - A Chinese Approach to Sustainable Manufacturing-

SMART Manufacturing Technologies - A Chinese Approach to Sustainable Manufacturing- ICSM AMT Center at Tongji University Shanghai SMART Manufacturing Technologies - A Chinese Approach to Sustainable Manufacturing- Dr. Ö.S. Ganiyusufoglu -. 葛兴福 Consultant to Chairman of Shenyang Machine

More information

电池柜 B32 Battery Cabinet B32. 安装说明 Installation Instruction

电池柜 B32 Battery Cabinet B32. 安装说明 Installation Instruction 电池柜 B Cabinet B 安装说明 Installation Instruction 目录 Contents 一 概述 Summarize 二 电池柜的组成 cabinet composing 三 电池柜的安装步骤 Installation method 四 电池柜的接线图 The wiring diagrams for battery cabinet 敬请周知 操作之前, 请详细阅读使用手册,

More information

Qualanod Specifications. Edition 1 st January 年 1 月 1 日版

Qualanod Specifications. Edition 1 st January 年 1 月 1 日版 Qualanod - 2017 Specifications Edition 1 st January 2017 2017 年 1 月 1 日版 Fore-runner of Qualanod Qualanod 的前生 1969 The EWAA quality label for anodized aluminium 1969 年 -EWAA( 欧洲锻铝协会 ) 铝阳极氧化质量标志 2 Foundation

More information

半桥驱动器 : 采用变压器还是全硅驱动? Half-Bridge Drivers A Transformer or an All-Silicon Drive?

半桥驱动器 : 采用变压器还是全硅驱动? Half-Bridge Drivers A Transformer or an All-Silicon Drive? www.onsemi.cn 半桥驱动器 : 采用变压器还是全硅驱动? Half-Bridge Drivers A Transformer or an All-Silicon Drive? 议程 Agenda 使用半桥配置的拓扑结构 Topologies using a half-bridge configuration 软开关与硬开关的区别 The difference between soft and

More information

Product Specification

Product Specification Product Specification Product Name: 150W micro infrared remote control LED driver Product Model: LDP-150M054 CE UL LDP-150R054 CE UL Rev. A.1 Address: Sangtai Industrial Park Guanwai Xiaobaimang Songbai

More information

操作说明书 Operating Instructions

操作说明书 Operating Instructions 267 操作说明书 Operating Instructions Class 267 Operating Instructions 267 操作说明书 Table of Contents/ 目录 1 General... 6 1.1 1.2 1.3 1.4 Class 267- with subclasses... 6 References and illustration... 6 Instaling

More information

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen: NeuVision 500 Features This monitoring system may be used to monitor patient s 6 physiological parameters: ECG, respiratory rate, body temperature, non-invasive blood pressure (NIBP), pulse oxygen saturation

More information

Synchronization Algorithms and VLSI Implementation for DC-OFDM based UWB System

Synchronization Algorithms and VLSI Implementation for DC-OFDM based UWB System Synchronization Algorithms and VLSI Implementation for DC-OFDM based UWB System By Jun Zhou Supervisor: Prof. Junyan Ren Examiner: Thesis Period: Aug 2009 Mar 2010 Department of Microelectronics, School

More information

RF4C050AP. V DSS -20V R DS(on) (Max.) 26mΩ I D ±10A P D 2W. Pch -20V -10A Middle Power MOSFET Datasheet

RF4C050AP. V DSS -20V R DS(on) (Max.) 26mΩ I D ±10A P D 2W. Pch -20V -10A Middle Power MOSFET Datasheet RF4C050AP Pch -20V -10A Middle Power MOSFET Datasheet V DSS -20V R DS(on) (Max.) 26mΩ I D ±10A l 外形図 HUML2020L8 P D 2W DFN2020-8S l 特長 1) 低オン抵抗 2) 小型ハイパワーパッケージ (HUML2020L8) 3) 鉛フリー対応済み RoHS 準拠 4) ハロゲンフリー

More information

Research and Analysis on Smart Home. Chao Dai West Institute,CAICT

Research and Analysis on Smart Home. Chao Dai West Institute,CAICT Research and Analysis on Smart Home Chao Dai West Institute,CAICT 2017.11.3 1 Course Objectives The definition of smart home Development status of Smart home Home intelligent research results sharing The

More information

8 English P.20 한국의 P.21 中 文 P.22

8 English P.20 한국의 P.21 中 文 P.22 8 English P. 20 한국의 P. 21 中文 P. 22 인터넷 시스템 이용가이드 络 统 0120-615-919 support@broad-e.co.jp http://b-cubic.com/user/ 英 :If you have any inquiries about settings or connection please contact the Internet

More information

Fabrication of Schottky Diode in Standard CMOS Process

Fabrication of Schottky Diode in Standard CMOS Process Fabrication of Schottky Diode in Standard CMOS Process Qiang Li, Junyu Wang,Yifeng Han, Hao Min, Feng Zhou (State Key Lab of ASIC&System, Fudan University, Shang Hai 200433) Abstract- This paper describes

More information

downloaded from

downloaded from CHINESE JOURNAL OF SHIP RESEARCH,VOL.13,NO.1,FEB 2018 59 Cite this article:wang Q, YUAN J S, ZHAO Q M. Inductance calculation of submarine DC transmission line based on finite element analysis[j/ol]. Chinese

More information

Warp knitting 经编机 MLF 46 / 24 MLF 60 / 32. Multibar Raschel machines for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机

Warp knitting 经编机 MLF 46 / 24 MLF 60 / 32. Multibar Raschel machines for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机 Warp knitting 经编机 MLF 46 / 24 MLF 60 / 32 Multibar Raschel machines for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机 Karl Mayer WARP KNITTING All-rounder to create EXPRESSIVE

More information

Product Specification

Product Specification Product Specification Product Name: 60W micro infrared remote control LED driver Product Model: LDP-060M080 CE UL LDP-060R080 CE UL Rev. A.2 Address: Sangtai Industrial Park Guanwai Xiaobaimang Songbai

More information

The Advanced Digital Microphone System for Acoustic Guitar USER MANUAL

The Advanced Digital Microphone System for Acoustic Guitar USER MANUAL The Advanced Digital Microphone System for Acoustic Guitar USER MANUAL Contents Table of Contents Contents 2 English 3 irig Acoustic Stage 3 Register your irig Acoustic Stage 3 Installation and setup 4

More information

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Dual Channel Function/Arbitrary Waveform Generators 4050B Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

The audience has given us a lot of positive feedback, some typical ones are listed below:

The audience has given us a lot of positive feedback, some typical ones are listed below: NEWSLETTER December 2010 Successful Closing of 2 nd Sharing Best Practice Workshop The 2 nd Sharing Best Practice Workshop held on 2 nd and 3 rd of December, 2010 at the Nansha Grand Hotel cohosted by

More information

Recent Results on the SUNIST and Device Upgrade

Recent Results on the SUNIST and Device Upgrade The 8 th General Scientific Assembly of the Asia Plasma and Fusion Association Guilin, China, 1-4 Nov. 211 (APFA 211 ) Recent Results on the SUNIST and Device Upgrade Zhe GAO ( 高喆 ) 1 and the SUNIST group

More information

Texas Instruments Sensing Portfolio 1Q18

Texas Instruments Sensing Portfolio 1Q18 Texas Instruments Sensing Portfolio 1Q18 1 TI 传感器产品 系统监控和保护 温度 电流 / 功率 磁 湿度 位置传感器 角度 压力 / 高度 距离 流量 速度 光和成像 光 医学成像 近红外 Time-of-Flight System Monitoring /Protection Position Sensing Imaging and Light 2 系统监控和保护产品

More information

Warp knitting 经编机 MLF 46 / 24. Multibar Raschel machine for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机

Warp knitting 经编机 MLF 46 / 24. Multibar Raschel machine for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机 Warp knitting 经编机 MLF 46 / 24 Multibar Raschel machine for the production of high-quality elastic and rigid lace 生产高品质无弹和弹力花边的多梳拉舍尔经编机 Karl Mayer WARP KNITTING An All-rounder to create EXPRESSIVE ALL-OVER

More information

Servo board bit machine software use: QSC32 Servo controller front. QSC32 Servo controller back

Servo board bit machine software use: QSC32 Servo controller front. QSC32 Servo controller back Servo board bit machine software use: QSC32 Servo controller front QSC32 Servo controller back QSC32E Servo controller illustrations 1, install the driver Using MINI-USB cable to connect the Servo board

More information

FUCHS Cutting Fluids influence on High speed Cutting Operations High Tech Lubricants for high Tech Process

FUCHS Cutting Fluids influence on High speed Cutting Operations High Tech Lubricants for high Tech Process FUCHS Cutting Fluids influence on High speed Cutting Operations High Tech Lubricants for high Tech Process Pudasaini Ravindra 29 th March Preface 目录 Gear Hobbing Operations 滚齿加工 Broaching Operations 拉削加工

More information

High frequency ratio antenna for RFID tags

High frequency ratio antenna for RFID tags High frequency ratio antenna for RFID tags Jieh-Sen Kuo *(1), Jyun-Jie Wang (2), and Chih-Yu Huang (3) (1) Department of Electronic Engineering, Kao-Yuan University, Kaohsiung, Taiwan 821, Republic of

More information

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation ArbStudio Arbitrary Waveform Generators Powerful, Versatile Waveform Creation UNMATCHED WAVEFORM UNMATCHED WAVEFORM GENERATION GENERATION Key Features 125 MHz bandwidth 1 GS/s maximum sample rate Long

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS880 (retrofit kit) 4/218 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUS880 (retrofit kit) 4/218 Siemens FI SITRNS F flowmeters Siemens G 2007 Overview pplication Irrigation systems Irrigation distribution systems Pumping stations Canal laterals On-farm outlets Water well production rip and sprinkler irrigation

More information