IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others

Size: px
Start display at page:

Download "IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others"

Transcription

1 IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER INTRODUCTION 25 reasons to differentiate Impulse 6000D/7000DP from all others Function 1. Compatible with full range of defibrillation technologies (monophasic, bi-phasic and pulsed bi-phasic) in the healthcare market 2. First-class measurement accuracy 3. Physiological ECG waveforms to test different AEDs 4. User-selectable pacer measurement algorithms for testing wide range of brand selections 5. Full compliment of built-in pacer testloads (from 50 to 1,500 ohms) 6. Flexible heart-rate setting facilitates rate meter & alarm testing (1 BPM per step) 7. Easy-to-use connection posts for 12 Lead ECG (10 electrodes) 8. Wide range of Arrhythmia selections 9. Auto-range defib & pacer measurement using DSP technology 10. Optional Ansur PC software for automation and standardization or test procedures, as well as print and data management/storage 11. Ready for external multiple patient defibrillation test loads (25 to175 ohms) (optional, available Q4, 2007) 12. Very low inductance (<2uH) test resistor Ergonomics 1. Portable and easy to carry 2. Rugged design 3. Intuitive user interface 4. Backlight, easy-to-read display 5. Large LCD with big numbers 6. USB port 7. Long-lasting, rechargeable NiMH battery 8. Modern, eye-catching new packaging by mechanical & industrial designers design Other Features 1. DSP (Digital Signal Processor) based measurement 2. Safety standard compliance (IEC 61010): total electrical isolation 1

2 3. Future upgradeable: firmware, software and new waveforms 4. Global support network LCD Low level ECG Backlight Power switch Pacemaker input (50 to 1500 ohms) t Navigator Device selection Function 1) Plug-in defib. paddle contact plates. (Removable to expose 4mm safety jacks) 2) Main 50-ohm testload input for both external defibrillator & pacemaker. 2

3 SETUP INFO 1. Momentarily press and then release the POWER ON pushbutton. The main menu appears on the analyzer s display. The battery ICON in the upper-right of the display indicates the relative charge level of the analyzer s internal battery. (If ICON is showing less than 2 vertical bars, connect analyzer to the supplied power supply and plug into mains/power receptacle. 2. Select the SETUP button to view setup info. a. F1: BATTERY status to show how much battery left b. F2: DISPLAY c. F3: SOUND d. F4: MORE 3

4 3. To set up unit for test, apply ECG leads to the ten AHA (color on the left side of the post) and IEC (color on the right) color-coded safety terminals as appropriate. 4

5 DEFIBRILLATION TESTS THE ENERGY TEST 1. Select DEFIB mode on the left panel, then select a test. a. Press F1 ENERGY b. Press F1 Set Wave and then select VFib from list using the UP/DOWN keys c. Press F2 Wave Conversion and select convert from list using the UP/DOWN keys 2. Place the defibrillator paddles securely on the analyzer contact plates to discharge the defibrillator or use Optional Accessories (disposable pad adapters) by removing the two defib paddle plug-in plates. 5

6 3. The analyzer calculates the energy delivered over the load resistance and displays the result in joules under the result. Press F4 for summary 4. Show on the monitor that ECG waveform is converted from V. Fib. to Normal Sinus Rhythm.. Ventricular Fibrillation Normal Sinus Rhythm 5. Following the same procedures if testing an AED (Automated External Defibrillator 6

7 THE SYNCHRONIZATION TEST (Cardioversion) Measures the time delay in milliseconds (ms) between the peak of the R wave and the discharging of the defibrillator pulse. A wide range of simulated ECG waveforms are available in the analyzer for performing this test. Atrial fibrillation (AFIB) is the most representative clinical waveform for demonstration purposes. Two selections are available; AFIB-Coarse is the default simulation. 1. Press F2 Sync 2. Press F1 Set Wave Use UP/DOWN arrow keys to select an ECG waveform. AFIB is chosen for the purpose of this demonstration. 3. Note ability to change AMPLITUDE and RATE. Select F5 for DONE. 4. Select F2 to select WAVE CONVERSION. Three choices are listed: CONVERT, NO CONVERT and ASYSTOLE. Convert is chosen for the purpose of this demonstration 7

8 5. Power on the defibrillator. Select the desired energy, place the paddles and discharge. Note for the purpose of this demonstration, AFIB is converted to a normal heart waveform. Atrial Fibrillation Normal Sinus Rhythm a. Notice the results screen on the Impulse 6000D/7000DP (delay time, etc). 8

9 THE CHARGE TIME TEST Tests the batteries and charging capacity in the defibrillator 1. Select F3 for CHARGE TIME test. 2. Select F3 for MEASURE a. Notice CHARGE TIME screen counting down Select desired energy level and then charge defibrillator.rillator when the count reaches zero and the internal beeper sounds... When the selected energy level is reached, discharge the paddles. a. Notice the results screen CHARGE TIME = s. Please note that typical charge times are under 10 seconds. 9

10 PACER TESTS Tests wide range of transcutaneous pacemakers; measures and displays pacer pulse amplitude, rate, width and energy. Conducts demand and sensitivity tests, measures and displays refractory periods, etc. 1. Connect pacer to the analyzer through either defibrillator input (50 ohms only) or pacer input (50 to 1500 ohms) 2. Select PACER mode on the left panel. Select F1 to set the pacer BRAND. 3. Select F2 to select Input Jack options. When defibrillator input is chosen, load is limited to 50 ohms. If pacer jack input is selected, testload is selectable between 50 to 1500 ohms. Please note that typical pacer outputs are specified at testloads between 50 10

11 and 600 ohms. Select F3 to change pacer loads. Turn pacer on and adjust pacer rate and output. 8. Observe pacer Measurement result screen 9. Select F4 to view more tests (F1 = SENSITIVITY, F2 = REFRACTORY PERIOD). Sensitivity test (Demand sensitivity is the minimal QRS amplitude (mv) required to cause the pacer to operate in the demand mode) Refractory period test (Measure the time interval in milliseconds (ms) during which the pacemaker is insensitive to any external inputs) 11

12 ECG TESTS THE ECG MONITOR TEST 1. Select ECG mode on the left panel. a. SELECT WAVE TYPE screen appears a. F1 = NORMAL SINUS (rates from bpm by 1 bpm step), b. F2 = PERFORMANCE (can choose different wave forms such as square, pulse, sine and triangle), c. F3 = PACER INTERACTIVE. Selections Under F3 are: a. Non-capture: the analyzer operates in continuous mode. However, every 10th pacer pulse is not captured b. Asynchronous: The heart is totally controlled by the Pacer c. Non-function: none of pacer pulse is captured by heart d. Demand: if pacer pulse is higher than heart rate, pacer takes over heart. If pacer pulse is lower than heart rate, pacer silences. 2. Select F4 for more wave types. a. Wave types: a. F1 SUPRA VENTRICULAR 12

13 b. F2 PREMATURE c. F3 VENTRICULAR d. F4 MORE b. Selects F4 again a. Wave types: i. F1 CONDUCTION ii. F2 TV PACED iii. F3 R WAVE DETECTION iv. Noise Immunity For more information, please see the Impulse 6000D/7000DP Defibrillator/Tranacutaneous Pacemaker Analyzer Getting Started Guide and User Manual. 13

Impulse 6000D/7000DP Defibrillator/External Pacer Analyzer

Impulse 6000D/7000DP Defibrillator/External Pacer Analyzer mpulse 6000D/7000DP Defibrillator/External Pacer Analyzer Technical Data The mpulse 6000D Defibrillator Analyzer and mpulse 7000DP Defibrillator/Transcutaneous Pacer Analyzer Test Systems are rugged, portable

More information

User Manual. DA-2003P Defibrillator Transutaneous Pacemaker Analyzer

User Manual. DA-2003P Defibrillator Transutaneous Pacemaker Analyzer User Manual DA-2003P Defibrillator Transutaneous Pacemaker Analyzer CONTENTS I. MANUAL REVISION RECORD... 2 II. INTRODUCTION... 3 2.1 Features 2.2 General Information III. SPECIFICATIONS... 4 3.1 Defibrillator

More information

DEFIBRILLATOR ANALYZERS

DEFIBRILLATOR ANALYZERS DEFIBRILLATOR ANALYZERS DA-2006 DA-2006P W/ PACER ANALYZER USER MANUAL BC BIOMEDICAL DA-2006 SERIES TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... iii DESCRIPTION... 1 LAYOUT... 7 DEFIBRILLATOR ANALYZER...

More information

Phase. Defibrillator and Transcutaneous Pacemaker Analyzer. Operating Manual

Phase. Defibrillator and Transcutaneous Pacemaker Analyzer. Operating Manual Phase 3 Defibrillator and Transcutaneous Pacemaker Analyzer Operating Manual Phase 3 Defibrillator and Transcutaneous Pacemaker Analyzer Operating Manual 2007-2014 Datrend Systems Inc. 130-4020 Viking

More information

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry Main problem: heart muscle fibers are continuously stimulated by adjacent muscles

More information

Impulse 6000D. Impulse 7000DP. Defibrillator Analyzer. Defibrillator/Transcutaneous Pacer Analyzer. Getting Started Manual

Impulse 6000D. Impulse 7000DP. Defibrillator Analyzer. Defibrillator/Transcutaneous Pacer Analyzer. Getting Started Manual Impulse 6000D Defibrillator Analyzer Impulse 7000DP Defibrillator/Transcutaneous Pacer Analyzer Getting Started Manual PN 3028662 August 2007 2007 Fluke Corporation, All rights reserved. Printed in USA

More information

TEST PASSED. Date: 07/03/2016 Ansur Version Record:

TEST PASSED. Date: 07/03/2016 Ansur Version Record: ElecoTek INC 1640 W. Hubbard Street Unit B Chicago IL 60622 312-631-3692 https://www.elecotek.com Test Record TEST PASSED Test Performed Ansur Components Used Date: 07/03/2016 Ansur Version 3.0.0 Record:

More information

BioTester Version 3.02 Copyright, October, 2010

BioTester Version 3.02 Copyright, October, 2010 SRI BioTester Version 3.02 Copyright, October, 2010 Stirling Rock International Tel. 612 9482 4973 Page 1 of 16 BioTester The manufacturer assumes no responsibility for the use of this product in a medical

More information

At the core of your critical care emergency response

At the core of your critical care emergency response At the core of your critical care emergency response Effi cia DFM100 defi brillator/monitor To deliver high levels of care, you need to make quick, informed decisions at the scene of an emergency and across

More information

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual medlab Three Lead ECG OEM board EG01010 Technical Manual Copyright Medlab 2008-2016 Version 1.03 1 Version 1.03 28.04.2016 Medlab GmbH Three Lead

More information

MULTI-PARAMETER PATIENT SIMULATOR

MULTI-PARAMETER PATIENT SIMULATOR MULTI-PARAMETER PATIENT SIMULATOR PS-2110 USER MANUAL BC BIOMEDICAL PS-2110 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 5 ECG--NORMAL SINUS RHYTHM... 13 ECG--ARRHYTHMIAS...

More information

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD D500 Defibrillator/Monitor LCD Waveform & Text display NIBP Temperature 1 Temperature 2 IBP 1 IBP 2 Capnography Integrated Thermal Printer Nellcor Oximax Sp02 Pulse Oximetry Biphasic Defibrillation, Pacing

More information

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen: NeuVision 500 Features This monitoring system may be used to monitor patient s 6 physiological parameters: ECG, respiratory rate, body temperature, non-invasive blood pressure (NIBP), pulse oxygen saturation

More information

CATALOG. ESU-2400H ESU Analyzer See Page NIBP-1040Kit-E Patient Simulator See Page Ultrasound Transducer Leakage Tester

CATALOG. ESU-2400H ESU Analyzer See Page NIBP-1040Kit-E Patient Simulator See Page Ultrasound Transducer Leakage Tester A UNIT OF BC GROUP INTERNATIONAL, INC. 2014-2015 CATALOG Cardiac Output Fetal Maternal NIBP IBP ECG Arrhythmias Performance SPO2 Temp ESU-2400H ESU Analyzer See Page 25-26 The Only Multi-Pulse Analyzer

More information

Medlab GmbH EG04000 User Manual. medlab. Four Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1.

Medlab GmbH EG04000 User Manual. medlab. Four Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1. Medlab GmbH EG04000 User Manual medlab Four Lead ECG OEM board EG04000 Technical Manual Copyright Medlab 2014 1 Medlab GmbH EG04000 User Manual Medlab medizinische Diagnosegeräte GmbH Helmholtzstrasse

More information

ECG Set. We Simplify the Procedures and You Save Time!

ECG Set. We Simplify the Procedures and You Save Time! ECG Set We Simplify the Procedures and You Save Time! WhaleTeq ECG Set Standard coverage: IEC 6060--5, --7, --47, AAMI/ANSI EC, EC, EC8, EC57, YY079, YY9, YY078, etc. Adopted by International Certification

More information

Technical data ESA614 Electrical Safety Analyzer

Technical data ESA614 Electrical Safety Analyzer Technical data ESA614 Electrical Safety Analyzer The ESA614 Electrical Safety Analyzer brings fast and simple automated testing in the form of a portable analyzer to healthcare technology professionals

More information

Medlab GmbH EG05000 User Manual. medlab. Five Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1.

Medlab GmbH EG05000 User Manual. medlab. Five Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1. Medlab GmbH EG05000 User Manual medlab Five Lead ECG OEM board EG05000 Technical Manual Copyright Medlab 2016 1 Medlab GmbH EG05000 User Manual Medlab GmbH support@medlab.eu www.medlab.eu 2 Medlab GmbH

More information

Defibrillation made simple

Defibrillation made simple Defibrillation made simple Philips 861290 HeartStart XL+ defibrillator/monitor Product is not available for sale in the U.S. For resuscitation teams and rapid response teams, the Philips HeartStart XL+

More information

Defibrillator ECG Monitor/Recorder, LIFEPAK 10

Defibrillator ECG Monitor/Recorder, LIFEPAK 10 TO BE INSPECTED IS T MISSION CAPABLE IF: 1 S Defibrillator a. Conduct an inventory to ensure that the items listed on the Parts and Accessories List are on hand. b. Ensure Operator Preventive Maintenance

More information

REANIBEX Serie 700. Technical Manual

REANIBEX Serie 700. Technical Manual REANIBEX Serie 700 Technical Manual Approved: R&D Director Revision: H Date: December - 2011 Revision G 07/2011 All rights for this publication are reserved. This manual may not be totally or partially

More information

MEDTEQ Single Channel ECG System 3.0. Operation Manual

MEDTEQ Single Channel ECG System 3.0. Operation Manual MEDTEQ Single Channel ECG System 3.0 Operation Manual Revision 2010-10-04 Blank page Contents 1 Introduction... 4 1.1 Basic concept... 4 1.2 Standards... 5 1.3 Block diagram / USB Module overview... 6

More information

4830B accelerometer simulator Product overview

4830B accelerometer simulator Product overview 4830B accelerometer simulator Product overview 2015 Product overview Simulates the electrical output signals generated by common measurement transducers (vibration, pressure, acoustics, etc.) Portable,

More information

HEARTSTART MRx MONITOR/DEFIBRILLATOR

HEARTSTART MRx MONITOR/DEFIBRILLATOR HEARTSTART MRx MONITOR/DEFIBRILLATOR PRODUCT DESCRIPTION No compromises. That s how we created the HeartStart MRx, a combination transport monitor, cardiograph, manual defibrillator, and AED. HeartStart

More information

Medlab GmbH. EG12000 User Manual. medlab. Twelve Lead ECG OEM board EG Technical Manual. Copyright Medlab Version 1.05

Medlab GmbH. EG12000 User Manual. medlab. Twelve Lead ECG OEM board EG Technical Manual. Copyright Medlab Version 1.05 Medlab GmbH EG12000 User Manual medlab Twelve Lead ECG OEM board EG12000 Technical Manual Copyright Medlab 2013 1 EG12000 User Manual Medlab G mbh 2 Medlab GmbH EG12000 User Manual Table of Content Mechanical

More information

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL UCORE ELECTRONICS www.ucore-electronics.com 2017 Contents 1. Introduction... 2 2. Turn on or turn off... 3 3. Oscilloscope Mode... 4 3.1. Display Description...

More information

Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2

Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2 walk400h walk400h walk400h is a latest-generation holter recorder able to acquire and memorise from 3 to 12 ECG channels, compatible with the holter reader software CARDIOLINE, for details of which see

More information

Helping you improve patient care. Welch Allyn Holter Systems

Helping you improve patient care. Welch Allyn Holter Systems Helping you improve patient care. Welch Allyn Holter Systems Welch Allyn Holter Systems User-friendly, powerful systems that are tailored to meet your needs. Welch Allyn Holter Systems feature easy-to-use

More information

i-pad NF1200 Service Manual CU Medical Systems, Inc.

i-pad NF1200 Service Manual CU Medical Systems, Inc. i-pad NF1200 Service Manual CU Medical Systems, Inc. 1 i-pad NF1200 Quick Reference Card Rescue Steps 1. Connect the defibrillator pads to the i-pad and then place on patient. 2. Stand clear and press

More information

Panorama TELEPACK 608

Panorama TELEPACK 608 Quick Reference Guide Datascope Panorama TELEPACK 608 SpO 2 Panorama_Telepk QRG_0003_rB.indd 1 Note: The Panorama Telepack SpO 2 Quick Reference Guide is not intended as a replacement to the Operating

More information

ipad SP1 Automated External Defibrillators

ipad SP1 Automated External Defibrillators NOMINATED DEVICE ipad SP1 Automated External Defibrillators ipad SP1 Carry Case ipad SP1 Fully Automatic ipad SP1 Semi Automatic Semi or fully automatic. The choice is yours. #creatinglifesavers Trusted

More information

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1 UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL FATIH GENÇ UCORE ELECTRONICS www.ucore-electronics.com 2017 - REV1 Contents 1. Introduction... 2 2. Turn on or turn off... 3 3. Oscilloscope Mode... 3 3.1. Display

More information

PRODUCT SHEET IMPORTANT SAFETY NOTES!

PRODUCT SHEET IMPORTANT SAFETY NOTES! STMISO STIMULUS ISOLATION ADAPTERS See also: Stimulator Setup notes in AcqKnowledge Software Guide BIOPAC offers three stimulus isolation adapters: STMISOC constant current or constant voltage (5X / 10X)

More information

LIFEPAK 20e DEFIBRILLATOR/MONITOR. with CodeManagement Module

LIFEPAK 20e DEFIBRILLATOR/MONITOR. with CodeManagement Module PRODUCT PRODUCT BROCHURE BROCHURE LIFEPAK 20e DEFIBRILLATOR/MONITOR with 1 LIFEPAK 20e Amidst financial pressures and evolving guidelines, your hospital remains focused on saving lives. With the LIFEPAK

More information

PRODUCT BROCHURE. LIFEPAK 20e DEFIBRILLATOR/MONITOR. with CodeManagement Module

PRODUCT BROCHURE. LIFEPAK 20e DEFIBRILLATOR/MONITOR. with CodeManagement Module PRODUCT BROCHURE LIFEPAK 20e DEFIBRILLATOR/MONITOR with CodeManagement Module Amidst financial pressures and evolving guidelines, your hospital remains focused on saving lives. With the LIFEPAK 20e defibrillator/monitor,

More information

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER WARNING Only a physician can order a Holter ECG test. WARNING Only the ordering physician can decide on the application technique used for affixing

More information

OPERATOR S GUIDE Rev YF October, x OFF SHOCK ECG DEFIB CO2 PACER. Param Wave 2 ID# Alarms LEAD SIZE HR CHARGE SIZE

OPERATOR S GUIDE Rev YF October, x OFF SHOCK ECG DEFIB CO2 PACER. Param Wave 2 ID# Alarms LEAD SIZE HR CHARGE SIZE OPERATOR S GUIDE LEAD SIZE HR m CO2 31 m Hg Sp02 % ECG x1.5 72 17RR 100 PADS ECG CO2 LEAD SIZE ALARM SUSPEND RECORDER MONITOR OFF CHARGE ENERGY SELECT 1 2 3 DEFIB ANALYZE SHOCK PACER Param Wave 2 ID# Alarms

More information

Philips Telemetry System and Telemetry Functions at the IntelliVue Information Center

Philips Telemetry System and Telemetry Functions at the IntelliVue Information Center Philips Telemetry System and Telemetry Functions at the IntelliVue Information Center Notice - for USA only Operation of this equipment requires the prior coordination with a frequency coordinator designated

More information

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc. P a g e 1 ST985 TDR Cable Analyzer Instruction Manual Analog Arts Inc. www.analogarts.com P a g e 2 Contents Software Installation... 4 Specifications... 4 Handling Precautions... 4 Operation Instruction...

More information

ECG PATIENT SIMULATOR SIX LEAD

ECG PATIENT SIMULATOR SIX LEAD ECG PATIENT SIMULATOR SIX LEAD PS-2006 USER MANUAL BC BIOMEDICAL PS-2006 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field. LINE TESTER LT51 The LT51 Line Tester is a portable handheld battery powered instrument. It combines the features of several pieces of test equipment such as a Selective Level Meter / Spectrum Analyser,

More information

6. Cloud Database retrieval of ECG reports by Mobile Phone, Tablet, or Notebook.

6. Cloud Database retrieval of ECG reports by Mobile Phone, Tablet, or Notebook. CardioScan 77a, with Build Date 20141117 v.78a This Section A is for Holter customers who are updating their CardioScan Software. 1. Additional ECG Analysis capabilities. 2. New Editing Process. 3. Respiration

More information

ECG HOLTER INtUItIVe USeR INteRFAce Interactive Graphs Interactive Histograms navigation by extremes Fully Customizable R E LT O H CG E

ECG HOLTER INtUItIVe USeR INteRFAce Interactive Graphs Interactive Histograms navigation by extremes Fully Customizable R E LT O H CG E ECG HOLTER new 2 ecg Holter NEW POSSIBILITIES IN HOLTER DIAGNOSTICS btl ecg Holter The BTL ECG Holter satisfies the needs of the most demanding ECG experts, while at the same time making their work both

More information

Instructions for Use: DSP-523 True-RMS 3 Axis DSP Gaussmeter Magnii Technologies

Instructions for Use: DSP-523 True-RMS 3 Axis DSP Gaussmeter Magnii Technologies Instructions for Use: DSP-523 True-RMS 3 Axis DSP Gaussmeter Magnii Technologies www.magnii.com FEATURES 3 Axis AC Gaussmeter: Accurately measure AC magnetic fields regardless of meter orientation. Advanced

More information

Biomedical Test. Product Catalog 2009/2010. Fluke Biomedical. Better products. More choices. One company. ESA620 Electrical.

Biomedical Test. Product Catalog 2009/2010. Fluke Biomedical. Better products. More choices. One company. ESA620 Electrical. Biomedical Test Product Catalog 2009/2010 ESA620 Electrical Safety Analyzer ESA612 Electrical Safety Analyzer Impulse 7000DP Defibrillator/ Transcutaneous Pacemaker Analyzer Fluke Biomedical. Better products.

More information

Lab E5: Filters and Complex Impedance

Lab E5: Filters and Complex Impedance E5.1 Lab E5: Filters and Complex Impedance Note: It is strongly recommended that you complete lab E4: Capacitors and the RC Circuit before performing this experiment. Introduction Ohm s law, a well known

More information

Transcutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using

Transcutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using Transcutaneous Electrical Nerve Stimulator TENS 212 Instruction Manual Read before using TABLE OF CONTENTS GENERAL DESCRIPTION 1 SYSTEM COMPONENTS 1 WARRANTY 1 INDICATIONS AND CONTRAINDICATIONS 2 WARNINGS

More information

TSA 6000 System Features Summary

TSA 6000 System Features Summary 2006-03-01 1. TSA 6000 Introduction... 2 1.1 TSA 6000 Overview... 2 1.2 TSA 6000 Base System... 2 1.3 TSA 6000 Software Options... 2 1.4 TSA 6000 Hardware Options... 2 2. TSA 6000 Hardware... 3 2.1 Signal

More information

Volume 1 INTERNATIONAL PRODUCT CATALOG DALE TECHNOLOGY. Number one in value.

Volume 1 INTERNATIONAL PRODUCT CATALOG DALE TECHNOLOGY. Number one in value. INTERNATIONAL PRODUCT CATALOG Volume 1 DALE TECHNOLOGY Number one in value. ABOUT US In a small basement in Westchester County, New York, Dale Technology was formed. Dale Technology began in October, 1972,

More information

Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock Ivan Dotsinsky, Tatyana Neycheva* Centre of Biomedical Engineering Prof. Ivan Daskalov - Bulgarian Academy of Sciences 105, Acad. G.

More information

instead we hook it up to a potential difference of 60 V? instead we hook it up to a potential difference of 240 V?

instead we hook it up to a potential difference of 60 V? instead we hook it up to a potential difference of 240 V? Introduction In this lab we will examine the concepts of electric current and potential in a circuit. We first look at devices (like batteries) that are used to generate electrical energy that we can use

More information

1510A PRECISION SIGNAL SIMULATOR

1510A PRECISION SIGNAL SIMULATOR A worldwide leader in precision measurement solutions Portable signal source for calibrating electronic equipment and machinery monitoring systems. 1510A PRECISION SIGNAL SIMULATOR Voltage Signals Charge

More information

Application Note 175 Using the STMISOC Stimulus Isolator

Application Note 175 Using the STMISOC Stimulus Isolator APPLICATION NOTE 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com 02.14.2018 Application Note 175 Using the The MP160/150 System stimulation features

More information

Technical Manual. External Dual Chamber Pacemaker. M a n u f a c t u r e r

Technical Manual. External Dual Chamber Pacemaker. M a n u f a c t u r e r Technical Manual PACE 203 External Dual Chamber Pacemaker M a n u f a c t u r e r Osypka Medical GmbH Albert-Einstein-Strasse 3 D-12489 Berlin, Germany Phone: +49 (30) 6392 8300 Fax: +49 (30) 6392 8301

More information

ULTRA RAPID POWER QUALITY ANALYZER

ULTRA RAPID POWER QUALITY ANALYZER ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with

More information

Digital Function Generator

Digital Function Generator Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions

More information

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1 Mars-Energo Volt/mA Calibrator CALMAR-S User s manual Edition 3.1 Manufacturer: OOO NPP Mars-Energo Address: V.O. 13 Line, 6-8, office 41H, Saint-Petersburg, Russia, 199034 2017 MARS-ENERGO Table of contents

More information

ScopeMeter 190 Series II

ScopeMeter 190 Series II ScopeMeter 190 Series II Fluke 190-062, -102, -104, -202, - 204, -502 Service Manual PN 4822 872 05405 July 2011, Rev. 2, March 2012 2011, 2011, 2012 Fluke Corporation, All rights reserved. Printed in

More information

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1 BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1 Dr. Gari Clifford Hilary Term 2013 1. (Exemplar Finals Question) a) List the five vital signs which are most commonly recorded from patient monitors in high-risk

More information

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field. LINE TESTER LT51 The LT51 Line Tester is a portable handheld battery powered instrument. It combines the features of several pieces of test equipment such as a Selective Level Meter / Spectrum Analyser,

More information

PHYSIOFLOW Q-LINK TM

PHYSIOFLOW Q-LINK TM PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...

More information

Sensitivity of Series Direction Finders

Sensitivity of Series Direction Finders Sensitivity of Series 6000-6100 Direction Finders 1.0 Introduction A Technical Application Note from Doppler Systems April 8, 2003 This application note discusses the sensitivity of the 6000/6100 series

More information

ECG PATIENT SIMULATOR FIVE LEAD

ECG PATIENT SIMULATOR FIVE LEAD ECG PATIENT SIMULATOR FIVE LEAD PS-2005 USER MANUAL BC BIOMEDICAL PS-2005 TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 MANUAL REVISIONS... 6 LIMITED WARRANTY... 6 SPECIFICATIONS...

More information

MegaPulse D5-P:2011 Instruction Manual

MegaPulse D5-P:2011 Instruction Manual MegaPulse IMPULSE TESTER D5-P:2011 Instruction Manual Dear Customer: Congratulations! Compliance West USA is proud to present you with your MegaPulse D5-P:2011 Impulse Tester. Your instrument features

More information

WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x

WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x WHALETEQ Single Channel ECG Test System (SECG 4.0) User Manual For Software Revision 5.0.x.x (Revision 2017-02-13) Contents 1 Introduction... 4 1.1 Basic concept... 4 1.2 Standards/Application... 5 1.3

More information

How to Simply Generate a Frequency Hop Modulation

How to Simply Generate a Frequency Hop Modulation How to Simply Generate a Frequency Hop Modulation Frequency Hop Modulation is a method of transmitting radio signals by rapidly switching a carrier wave over a series of distinct frequency channels. Frequency

More information

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula Lower scrap rate Improved process control ISO 9000 data collection Decreased machine downtime Accurate machine set up Weld optimization and Design of Experiments (DoE) Welding process diagnostics Weld

More information

In-depth Analysis of Cardiac Signals Using Novel Equipment and Software

In-depth Analysis of Cardiac Signals Using Novel Equipment and Software American Journal of Biomedical Engineering 2013, 3(4): 85-90 DOI: 10.5923/j.ajbe.20130304.01 In-depth Analysis of Cardiac Signals Using Novel Equipment and Software John Antonopoulos 1, Konstantinos Kalovrektis

More information

5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator

5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator 5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator Introduction Modern function/waveform generators are extremely versatile, going well beyond the basic sine, square, and ramp waveforms. Function

More information

The world s first 3 lead 14 day continuous ECG and remote event device.

The world s first 3 lead 14 day continuous ECG and remote event device. Patient Instruction Bklet The world s first 3 lead 14 day continuous ECG and remote event device. A very positive and quick way to get diagnosed. www.zensordevice.com The Zensor monitoring device is a

More information

ECG & Respiration Transmitter LX Operation Manual

ECG & Respiration Transmitter LX Operation Manual ECG & Respiration Transmitter LX-7120 Operation Manual Before using this device, read this operation manual thoroughly. Keep this manual near the device for future reference. Federal Law restricts this

More information

Lone Star Neuromodulation

Lone Star Neuromodulation Lone Star Neuromodulation Disruptive Pulse-Generator Technology Platform 1 Our Vision Target unmet clinical needs by creating a disruptive device platform that offers promising solutions for lowering costs,

More information

AED 10 TM Automatic External Defibrillator

AED 10 TM Automatic External Defibrillator AED 10 TM Automatic External Defibrillator User Manual Software version 2.06.XX ii Welch Allyn AED 10 Automatic External Defibrillator Copyright 2007 Welch Allyn. All rights are reserved. No one is permitted

More information

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Surge Generator T-1005(7) For fault location in LT and Control cables. Inbuilt DC high voltage testing up

More information

Toshiba Model 3000 With options T-A or T-B

Toshiba Model 3000 With options T-A or T-B Toshiba Model 3000 With options T-A or T-B OPERATION MANUAL Designed exclusively to operate with Toshiba Medical Systems CT Scanners Cardiac Trigger Monitor 2010 IVY Biomedical Systems Inc. All Rights

More information

RF Explorer. User Manual. RF Explorer User Manual v Page 1 of 13. Updated to firmware v1.05. Edition date: 2011/Mar/01.

RF Explorer. User Manual. RF Explorer User Manual v Page 1 of 13. Updated to firmware v1.05. Edition date: 2011/Mar/01. RF Explorer User Manual v1.05 - Page 1 of 13 RF Explorer User Manual Updated to firmware v1.05 Edition date: 2011/Mar/01 www.rf-explorer.com Please consider the environment before printing this manual.

More information

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EENG-201 Experiment # 4: Function Generator, Oscilloscope EENG-201 Experiment # 4: Function Generator, Oscilloscope I. Objectives Upon completion of this experiment, the student should be able to 1. To become familiar with the use of a function generator. 2.

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual Edition 1 Notice i-pad Operator s Manual CU Medical Systems, Inc. reserves the right to make changes on the device specifications contained in this manual at any time without prior notice or obligation

More information

Model 3150-B. Cardiac Trigger Monitor OPERATION MANUAL. GE Healthcare CT Scanners. Designed exclusively to operate with. GE Part Number:

Model 3150-B. Cardiac Trigger Monitor OPERATION MANUAL. GE Healthcare CT Scanners. Designed exclusively to operate with. GE Part Number: Model 3150-B OPERATION MANUAL Designed exclusively to operate with GE Healthcare CT Scanners GE Part Number: 5304770 Cardiac Trigger Monitor 2014 IVY Biomedical Systems Inc. All Rights Reserved. Part No.

More information

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement Fluke 192/196/199 MS 190 and MA 190 Users Manual Supplement 4822 872 00979 April 2000, Rev.2, 9/00 2000 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks

More information

3880 Technical Specifications_ DRAFT_A Page 1 of 11

3880 Technical Specifications_ DRAFT_A Page 1 of 11 3880 Technical Specifications_ DRAFT_A Page 1 of 11 3880 3880 Technical Specifications_ DRAFT_A Page 2 of 11 Type: Color TFT resistive touchscreen Screen Size: 25.7 cm (10.1 inches) diagonal Pixels: 800

More information

OPERATOR S GUIDE March Rev. L

OPERATOR S GUIDE March Rev. L OPERATOR S GUIDE March 2009 9650-1210-01 Rev. L An issue or revision date for this manual is shown on the front cover. If more than three years have elapsed since this date, contact ZOLL Medical Corporation

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

The future of installation testing is here. The 1650 Series Multifunction Testers

The future of installation testing is here. The 1650 Series Multifunction Testers The future of installation testing is here The 50 Series Multifunction Testers 50 Series Safer, easier installation testing. Robin and Fluke joined forces in 999 to become the largest supplier of hand-held

More information

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes United States Home >... > Oscilloscope Accessories > U1600 Series Oscilloscope Accessories > U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes Key Specifications Features Ni-MH Battery Pack,

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification No. E-MIG0603IN2.doc revised: 20.October 2004 1 MIG Tester Type MIG0603IN2 1 MIG Tester Type MIG0603IN2 1 1.1 Introduction 1 2

More information

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers The future of installation testing is here The Fluke 50 Series Multifunction Testers Fluke 50 Series Safer, easier installation testing. The 50 Series testers verify the safety of electrical installations

More information

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013 Benha University June 2013 Benha Faculty of Engineering Electrical Department Hospital Instrumentations (E472) 4 Th year (control) Dr.Waleed Abdel Aziz Salem Time: 3 Hrs Answer the following questions.

More information

The oscilloscope and RC filters

The oscilloscope and RC filters (ta initials) first name (print) last name (print) brock id (ab17cd) (lab date) Experiment 4 The oscilloscope and C filters The objective of this experiment is to familiarize the student with the workstation

More information

satech SynchroStar GPS 200 Series

satech SynchroStar GPS 200 Series satech SynchroStar GPS 200 Series KEY BENEFITS Designed with high quality oscillator OCXO the device is characterized by superior frequency stability and improved holdover performance that allows maintaining

More information

PS-416M User & Service Manual

PS-416M User & Service Manual PS-416M User & Service Manual PATIENT SIMULATOR 1-1 Copyright 1997 by METRON. All rights reserved. METRON: USA FRANCE NORWAY 1345 Monroe NW, Suite 255A 30, rue Paul Claudel Travbaneveien 1 Grand Rapids,

More information

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual IT-24 RigExpert 2.4 GHz ISM Band Universal Tester User s manual Table of contents 1. Description 2. Specifications 3. Using the tester 3.1. Before you start 3.2. Turning the tester on and off 3.3. Main

More information

GFL-1000 User Manual Ground Fault Locator

GFL-1000 User Manual Ground Fault Locator GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...

More information

Design And Development Of An Efficient And Cost Effective ECG Simulator Capable Of Generating Normal And Pathological ECG Signals

Design And Development Of An Efficient And Cost Effective ECG Simulator Capable Of Generating Normal And Pathological ECG Signals Design And Development Of An Efficient And Cost Effective ECG Simulator Capable Of Generating Normal And Pathological ECG Signals Muhammad Shafique Ayesha Naeem muhammad.shafique@riphah.edu.pk ayesha.naeem@gmail.com

More information

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard N4 Sweep Frequency Response Analyzer SFRA45 Standalone High Accuracy Transformer Analysis Leading wideband accuracy Wide frequency range Full Colour VGA Display PC software included Leading phase accuracy

More information

User manual AUTOMATED EXTERNAL DEFIBRILLATOR

User manual AUTOMATED EXTERNAL DEFIBRILLATOR User manual AUTOMATED EXTERNAL DEFIBRILLATOR Manufacturer Instramed Indústria Médico Hospitalar Ltda. Industrial Unity: Beco José Paris, 339 Pavilhão 19 Postal code: 91140-310 Porto Alegre RS, Brasil Phone/Fax

More information

Galix WinTer. Holter Analyzer

Galix WinTer. Holter Analyzer Galix WinTer Holter Analyzer User s Manual 2555 Collins Avenue, Suite C-5, Miami Beach, FL 33140, U.S.A. Tel.: (305) 534-5905 Fax: (305) 534-8222 INDEX 1 INTRODUCTION...4 1.1 CORRECT ELECTRODE PLACEMENT...4

More information

PRODUCT CODE: XT EN

PRODUCT CODE: XT EN PRODUCT CODE: XT-46006-EN XM400-31A04-07 i Manufacturer Xavant Technology Pty (Ltd) Unit 102, The Tannery Industrial Park, 309 Derdepoort Rd Silverton, Pretoria, South Africa, 0184 Tel: +27 (0) 12 743

More information