GRAF HALL ADA ASSESSMENT & SURVEY

Size: px
Start display at page:

Download "GRAF HALL ADA ASSESSMENT & SURVEY"

Transcription

1 OREGON STATE UNIVERSITY (OSU) GRAF HALL ADA ASSESSMENT & SURVEY

2 Sacramento Office 770 L Street, Suite 950 Sacramento, CA Tel: Fax: Silicon Valley Office 2225 E. Bayshore Road, Suite 200 Palo Alto CA Tel: consu lting.com January 14, 2015 Angelo Gomez Executive Director Office of Equity and Inclusion Oregon State University 330 Snell Hall Corvallis, OR Re: ADA Accessibility Survey and Assessment Graf Hall Dear Angelo, We are pleased to submit this report for Graf Hall. This report is part of our project to provide a Campus Accessibility Survey and Assessment for Oregon State University. It is our hope that this report w ill assist OSU in improving access to people w ith disabilities to campus facilities. SZS has been pleased to be a part of this effort to evaluate campus buildings using federal and state statutes and regulations, as w ell as universal design principles in order to create performance standards that w ill guide design, construction and maintenance on campus. We look forw ard to discussing our findings w ith your team. Regards, Syroun Z. Sanossian, Principal SZS Consulting Group LLC

3 ADA Assessment & Survey Graf Hall TABLE OF CONTENTS 1. EXECUTIVE SUM M ARY OF FINDINGS p. 1 a. Pedestrian Facilities and Exterior Spaces Analyzed p. 2 b. Building Entrances p INTERIOR SPACES First Floor p. 3 Second & Third Floors p BARRIER DATA RECORDS Exterior Area Barriers p. 6 Interior Area Barriers p. 13 Cost Estimate p. 408

4 ADA Assessment & Survey Graf Hall 1. EXECUTIVE SUMMARY OF FINDINGS The field investigation for the interior spaces began on June 28, The exterior site elements w ere assessed originally as part of the pedestrian facilities assessment in June- September 2011 and are included as an essential part of this report. Images of each physical element identified in this report w ere captured in HD digital photos w hile manual measurements w ere taken to establish as-built conditions to facilitate the process of cost estimating. Digital photographs are provided w ithin the report for each barrier to access, to facilitate the review of the data collected. We have found that technical data can be difficult to interpret w ithout a visual component; the photos provide a clear connection betw een the technical data and each barrier to access. This building is a pre-ada structure and many barriers to access w ere identified in the building. That is quite typical, as barriers to access exist in virtually every building, w hether new or existing. No perfect building exists in the real w orld. This ADA Assessment and Survey report is intended to not only identify barriers to access, but to provide solutions. The basis for this ADA Assessment and Survey process is the underlying desire on the part of OSU to improve access by relying on higher standards than the minimum requirements in state and federal building codes. SZS intends to provide the information in this report in a clear and easy to understand format. The information in this report is compiled for use by designated OSU staff and other interested persons, so the content is designed to be understood by professionals and laymen alike. The findings presented are both narrative and technical in nature; barriers to access identified during the field investigation process are documented in tw o w ays; 1. Narrative Analysis: The analysis of findings is contained in an executive summary in a narrative form that not only describes each type of barrier identified but also provides a discussion that analyses the functionality of physical elements. We also provide the reasoning and research behind the identification of barriers that conflict w ith universal design principles. This analysis may be accompanied by digital photographs or diagrams, w here applicable. NOTE: Understanding building function and usage is essential w hen interpreting the findings held in this report. The narrative is intended to facilitate this process. 2. Barrier Data Records: Individual barriers to access are entered into the SZS database so that technical information on the barriers can be provided as barrier data records. These barrier data records include digital photographs of each barrier identified, code references that determine the barrier to access, as-built measurements, barrier severity ratings, budgetary cost estimates, recommended solutions for barrier removal and a priority for barrier removal. The information is formatted w ith tw o barriers on each report page. In order to consolidate the report data, some of the more typical barriers found in multiple locations have been grouped w ithin the barrier data records w ith a description of the locations in w hich they w ere found. 1

5 ADA Assessment & Survey Graf Hall A. Pedestrian Facilities and Exterior Spaces Analyzed This report provides information on campus pedestrian facilities that serve the building. Many physical elements are part of the comprehensive w hole that creates a pedestrian facility. The fundamental elements evaluated as to w hether they provide accessible pedestrian facilities include the follow ing: Sidew alks Walkw ays Ramps Curb Ramps Blended Transitions Signalized Intersections Stairw ays (94% of people w ith disabilities are not mobility impaired) Benches and other Seating Elements Picnic Facilities The descriptions provided for physical elements in this report are intended to clearly describe the differences betw een each physical element, such as w hen a pedestrian route is a sidew alk, rather than a w alkw ay. The descriptions are intended to explain how the elements interact to form a cohesive pedestrian facility. Other more specific information described w ithin this section intends to provide guidance on determinations made in this report. The key to providing accessible pedestrian facilities is in recognizing that different people w ith disabilities have different needs. Setting policies that speak to the entire group is essential, rather than focusing one particular subset of the overall group. Universal design principles govern here physical elements should be usable to everyone that visits campus w ithout having to resort to any adaptation or specialized design. In summary, an accessible route exists w ithin a building, property boundary or interior space and is separate from the PROW. Pedestrian w alkw ays are similar to sidew alks as paved surfaces improved for use by pedestrians but w alkw ays are not located along or adjacent to the curb line, gutter or roadw ay and w alkw ays are generally not considered part of the PROW. The pedestrian facility is the combination of the PROW and the accessible route, w hich functions as a w hole to provide pedestrian access to facility entrances. As a public building governed by the ADA Standards, the building should have at least one accessible entrance. This building has 2 none accessible entrances that are detailed below. The building has an accessible route provided w ithin the site from accessible parking spaces and accessible passenger loading zones; public streets and sidew alks; and public 2

6 ADA Assessment & Survey Graf Hall transportation stops to the accessible building or facility entrance they serve 1 as compared to the 2010 ADA Standard for Accessible Design. Details on barriers identified in that route are provided w ithin the ADA Assessment and Survey of the pedestrian facilities provided as a separate report, as w ell as in the follow ing records. Please see the barrier data records for details. B. Building Entrances The building is located along SW Monroe Avenue, a major pedestrian w ay that borders the campus. Parking is provided on-site although the building entrance at the accessible parking leads to an interior stairw ay. No accessible entrances are provided to this building and no accessible vertical access (elevator) is provided in this building. The second and third floors of the building are connected to Rogers Hall by w ay of ramps. It is recommended to provide an accessible entrance on tw o sides of this building considering the lengthy pedestrian path betw een the entrances in proximity to the accessible route through campus. INTERIOR SPACES FIRST FLOOR Graf hall is a three-story pre-ada building. The building has no accessible entrances, although the entrance from SW Monroe Avenue and the tw o entrances on the w est side of the building each have a 5 step at the entry door landing. The first floor provides research laboratories, classrooms, offices for graduate students and a men and w omen s restroom, w hich are the only sanitary facilities in the building. No drinking fountains are provided on the first floor or upper floors. Barriers identified on the first floor include entrance doors to classrooms and offices that lacked accessible signage, door hardw are, door closer operating force/sw eep period w here door closers w ere installed and w here doors w ere identified w ith view panels, the panels w ere accessible to short people or w heelchair users. Laboratory spaces on the first floor w ere identified w ith expansive space, but w ere filled w ith equipment, desks, tables and other physical elements that often obstructed the passagew ay for able-bodied people, as w ell as those w ith mobility impairments. In many instances, the entry doors and light sw itches lacked accessible maneuvering clearance as either a result of the original design or due to the location of cabinets or other items that encroached into the space needed by w heelchair users to maneuver. The lack of accessible maneuvering clearance may necessitate the installation of automatic door opening devices at entrance doors to classrooms and laboratories in many locations. Most of the signage in this building w as identified as lacking tactile information, although classrooms w ere provided w ith tactile signs in some locations. The central corridor on the first floor w as lacking an evacuation plan. As a performance standard, it is recommended that lobby identification signage be provided on each floor in A DA Standards for A ccessible Design, Section Site A rriv al Points 3

7 ADA Assessment & Survey Graf Hall each central corridor that indicates the floor plan, the location of the person view ing the sign and the location of accessible features such as restrooms, elevator and drinking fountains in proximity to the location of the person reading the sign. This signage is especially useful in buildings such as Graf Hall w here only one set of restrooms is provided and the only form of vertical access provided is through another building. Exit stairw ays lacked accessible entry doors, tactile signage including level identification signage for the visually impaired and accessible handrails. No contrasting color w as identified at the stairw ay treads w hich can be important to those w ith low vision. As a performance standard, it is highly recommended to provide contrasting color at stairw ay treads to improve visibility for all users. A spiral staircase w as located in north east corner of the building but this staircase is not a part of the accessible route and w as not included in our assessment of this building. Many staff use only areas w ere identified in the building. These spaces include IT rooms, janitorial rooms, private faculty offices and associated spaces. Signage at the door/doorw ay to these spaces w as included in this report as it is located along the public circulation route of travel, but these interior spaces w ere not investigated as part of this assessment process. In general, institutions and organizations make staff-use-only areas accessible as needed through the reasonable accommodation process betw een the employer and employee. Senior project cages on the first floor w ere actual cages w ith non-accessible entrance doors and inadequate maneuvering space for the number of physical elements placed inside. The cage doors also lacked a smooth and uninterrupted bottom surface needed by people using w heelchair w ho need to push the door using their footrests. While performing that task, the footrests can get caught in the fence mesh and become trapped. While each of these cage/rooms functions as an office, each is in use as a public space and should be accessible. These cages and many of the labs in this building w ere identified w ith floor grates that had openings of more than 1 that could trap w heelchair w heels. These grates should be replaced. The MIME Composite Materials Lab 107 is located below the ground floor level and a stairw ay provides vertical access from the exterior and an interior location. A special access lift (w heelchair lift) is provided at this stairw ay, but the lift lacks accessible maneuvering clearance needed at all entry doors and the lift does not have accessible controls that allow for unassisted operation. The lift w as not functional at the time of the field investigation. In addition, the lift w as not properly installed w ith a pit that w ould allow the footing of the device to be installed as designed so that the small ramp attached to the lift could act as a transition plate, not a ramp. At present, the w heelchair lift landing has a slope of more than 20%. The Infrastructure Material Laboratory 100 w as identified w ith many various types of research areas. In these areas, to ensure access, one of each type of w orkstation (counter, desk, bar, etc.) that serves a specific purpose w ith specific equipment or devices should be accessible, rather than applying the overall 5% ratio to the entire laboratory. The Geotech Library w as also identified w ith original historic entry doors that w ere not accessible. In addition, as w as the case in meeting rooms in this building, the group table used in the library w as not accessible and other areas w here participants may sit w hile listening to a lecture or attending a meeting lacked space for a person using a w heelchair to also rest. 4

8 ADA Assessment & Survey Graf Hall SECOND AND THIRD FLOORS Barriers noted above in classrooms and labs w ere similar to those identified in the upper floors of the building. No restrooms or drinking fountains w ere located on these upper floors. No vertical access w as provided to reach these floors w ithin the building although connecting ramps w ere identified betw een Rogers Hall and Graf Hall on the second and third floors. The doors leading to these ramps w ere not accessible (heavy operation, no accessible threshold and the door landings w ere severely sloped) and the actual ramps lacked any form of level landing at top or bottom, accessible handrails, and the slope and cross slope measured at both ramps w as excessive. On the second floor, the driving simulator office, robotics labs and graduate student offices w ere identified w ith non-accessible entry door operating force, door hardw are, view panels not accessible to short people and w heelchair users and non-accessible maneuvering clearance blocked by file cabinets, furniture or stored items. Signage w as also not accessible and doorstops attached to the bottom 10 of doors at the push side could create trap conditions for w heelchair users. Also, these spaces lacked access at specialized w orkstations in the Driving Simulator Office and desks in the grad student offices. Many of the offices lacked maneuvering clearance needed by w heelchair users at entry doors and w ithin the interior spaces of the offices. Controls such as light sw itches, electrical outlets and shelves w ere also not accessible in the offices. Faculty office spaces and meeting rooms used for student meetings lacked accessible entry door hardw are, operating force w here closers w ere installed, accessible signage, view panels usable by short people and the spaces lacked maneuvering clearance w ithin the space to allow w heelchair users to participate in meetings. The clear floor space needed to enable use of w hiteboards and chalkboards w as blocked by furniture or stored items in some locations and the spaces generally lacked accessible light sw itches and outlets, accessible desks, computer w orkstations, coat racks and strobe devices. Where sinks w ere provided, access for w heelchair users and short people w as not available. The follow ing barrier data records provide more detailed information on the barriers described above. 5

9 EXTERIOR AREA BARRIERS

10 Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 249 Reference Dwg: 1 of 5 Location: Exterior South Entrance X Coordinate: Doors or Gates Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: LF As built : 4 Barrier Change in level greater than 1/2" leading to door 3" lip in clear floor space Rec. Solution: Construct a ramp or provide ISA directional sign to accessible entrance Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 250A Reference Dwg: 1 of 5 Location: Exterior Stairway Leading to Parking Lot X Coordinate: Stairways Handrail Extension Bottom 2010 ADAS Performance Standard: No Quantity: LF As built : 2 Barrier Extension not sloped for length of one tread beyond the last riser nosing Extension not sloped for the length of one tread long Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

11 Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 250B Reference Dwg: 1 of 5 Location: Exterior Stairway Leading to Parking Lot X Coordinate: Stairways Handrail Both Sides 2010 ADAS Performance Standard: No Quantity: LF As built : 8 Barrier No handrail provided at both sides of stairway No handrail provided at both sides Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 250C Reference Dwg: 1 of 5 Location: Exterior Stairway Leading to Parking Lot X Coordinate: Stairways Contrasting Color ADA 2010 ADAS Advisory Performance Standard: Yes Quantity: LF or TR As built : 25 Barrier No contrasting color on each tread of exterior stairway No contrasting color provided Rec. Solution: Consider providing contrasting color on each tread Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

12 Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 258 Reference Dwg: 1 of 5 Location: Exterior Accessible Route Parking Lot X Coordinate: Walkways Connecting Acc Route 25 CFR (i)(2) and 2010 ADAS Performance Standard: No Quantity: LF As built : 20 Barrier No connecting accessible route provided No accessible route connects accessible parking to accessible entrance at Graf Hall Rec. Solution: Provide additional walkway to connect to existing paths Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 251A Reference Dwg: 1 of 5 Location: Exterior West Stairway X Coordinate: Stairways Contrasting Color ADA 2010 ADAS Advisory Performance Standard: Yes Quantity: LF or TR As built : 52 Barrier No contrasting color on each tread of exterior stairway No contrasting color provided Rec. Solution: Consider providing contrasting color on each tread Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

13 Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 251B Reference Dwg: 1 of 5 Location: Exterior West Stairway X Coordinate: Stairways Handrail Both Sides 2010 ADAS Performance Standard: No Quantity: LF As built : 9 Barrier No handrail provided at both sides of stairway No handrail provided at both sides Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 251C Reference Dwg: 1 of 5 Location: Exterior West Stairway X Coordinate: Stairways Handrail Extension Bottom 2010 ADAS Performance Standard: No Quantity: LF As built : 2 Barrier Extension not sloped for length of one tread beyond the last riser nosing Extension not sloped for the length of one tread long Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

14 Field Date: 6/28/2011 Report Date 6/28/2011 Barrier #: 251D Reference Dwg: 1 of 5 Location: Exterior West Stairway X Coordinate: Stairways Vertical Access Directional Sign 2010 ADAS Barrier No form of vertical access provided at stairway to reach entry door or upper floors Provide accessible sign Rec. Solution: Provide directional sign leading to accessible entry Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 7/8/2011 Report Date 7/8/2011 Barrier #: 535 Reference Dwg: 1 of 5 Location: Exterior North Entrance X Coordinate: Doors or Gates Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 32 Barrier Change in level greater than 1/2" leading to door 4" step at landing Rec. Solution: Construct ramp to provide access to door landing or provide ISA directional sign to accessible e Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

15 Field Date: 7/8/2011 Report Date 7/8/2011 Barrier #: 538 Reference Dwg: 1 of 5 Location: Exterior Northeast West Walkway X Coordinate: Blended Transitions Truncated Domes 2010 ADAS Barrier No truncated domes provided at transition into roadway No detectable warning provided Rec. Solution: Provide accessible truncated domes as detectable warnings Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Two way intersection corners C,D Field Date: 7/8/2011 Report Date 7/8/2011 Barrier #: 537A Reference Dwg: 1 of 5 Location: Exterior Northeast East Walkway X Coordinate: Blended Transitions Cross Slope Existing (4.1% to 5.0%) 2010 ADAS Performance Standard: No Quantity: EACH Barrier Cross slope exceeds 2.0% As built : 1 4.5% cross slope Rec. Solution: Demolish existing and construct new blended transition Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Two way intersection corners C,D ADA Assessment and Survey

16 Field Date: 7/8/2011 Report Date 7/8/2011 Barrier #: 537B Reference Dwg: 1 of 5 Location: Exterior Northeast East Walkway X Coordinate: Blended Transitions Truncated Domes 2010 ADAS Barrier No truncated domes provided at transition into roadway No detectable warning provided Rec. Solution: Provide accessible truncated domes as detectable warnings Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Two way intersection corners C,D Field Date: 7/8/2011 Report Date 7/8/2011 Barrier #: Reference Dwg: Location: X Coordinate: Performance Standard: Barrier Quantity: As built : Rec. Solution: Barrier Severity: Cost Est Implementation Priority: Implementation Phase: Record left blank intentionally to facilitate printing Facility Function: Status: ADA Assessment and Survey

17 INTERIOR AREA BARRIERS

18 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1A Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Door Closer Exterior Automatic Door Performance Standard Performance Standard: Yes Quantity: EACH Barrier Door opening force exceeds 8.5 lbf As built : 1 Accessible entry doors lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: This door/lobby is the accessible entrance for the first floor of Graf Hall only. Upper access is provided through adjacent buildings using elevators provided Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1B Location: Floor 1 Lobby L0104 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 3 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

19 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1C Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Double doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1D Location: Floor 1 Lobby L0104 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Implementation Priority: 1 Implementation Phase: Double doors. 53 1/4" high ADA Assessment and Survey

20 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1E Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Door 10" Bottom Surface Door Stop 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Door stop interrupts min. 10" smooth bottom surface Door stops at bottom of door can create trapping condition Rec. Solution: Remove door stop or other element at bottom of door at push side Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1F Location: Floor 1 Lobby L0104 Doors or Gates Clear Width 2010 ADAS Barrier Clear width passage through door, sliding/folding door or gate is not min. 32" 28 3/4" clear width of single leaf Rec. Solution: Replace door or gate and frame Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

21 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1G Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Doormat 2010 ADAS & Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier Doormat not anchored to floor (possible trip hazard) Door mat not secured Rec. Solution: Secure exiting doormat or replace Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1H Location: Floor 1 Lobby L0104 Clear Floor Space Tactile Exit Signs Door 2010 ADAS Barrier Ground floor doors that exit to exterior lacks tactile exit sign Exit door with low level illuminated sign lacks tactile exit sign Rec. Solution: Provide sign stating EXIT at exit side of door Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

22 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1I Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 Fire doors lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Fire double doors to corridor Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1J Location: Floor 1 Lobby L0104 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 3 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

23 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1K Location: X Coordinate: Floor 1 Lobby L0104 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, " high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1L Location: Floor 1 Lobby L0104 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Hand sanitizer 53 1/2" high Rec. Solution: Relocate to area at min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

24 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1M Location: X Coordinate: Floor 1 Lobby L0104 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Valve protrudes 14 1/2" at 65" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1N Location: Floor 1 Lobby L0104 Alarms Fire Pull Operation 2010 ADAS Barrier Fire pull has no fist operable hardware Fire pull not fist operable Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $3, ADA Assessment and Survey

25 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1O Location: X Coordinate: Floor 1 Lobby L0104 Alarms Fire Pull Height 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Fire pull not between 42" and 48" high 61" high Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1P Location: Floor 1 Lobby L0104 Alarms Horn/Strobe Corridor 2010 ADAS Performance Standard: No Quantity: EACH Barrier No horn/strobes in corridor As built : 1 No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

26 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 1Q Location: X Coordinate: Floor 1 Lobby L0104 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: For rooms 104B, 104C Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2A Location: Floor 1 Stairway S0101 Stairways Sign Encl Stairway Level ICC A117.1 Barrier Tactile stairway signage not provided to indicate floor level No floor level ID sign provided Rec. Solution: Provide sign Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Also, tactile stairway signage not provided to indicate discharge level ADA Assessment and Survey

27 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2B Location: X Coordinate: Floor 1 Stairway S0101 Stairways Handrail Height 2010 ADAS Performance Standard: No Quantity: LF As built : 36 Barrier Handrail grip measured at center not 34" 38" high 30" 31" handrail grip height Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $8, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2C Location: Floor 1 Stairway S0101 Stairways Handrail Extension Bottom 2010 ADAS Performance Standard: No Quantity: LF As built : 0 Barrier Extension not sloped for length of one tread beyond the last riser nosing Bottom handrails lack extension the length of one tread Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

28 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2D Location: X Coordinate: Floor 1 Stairway S0101 Stairways Handrail Grip 2010 ADAS Performance Standard: No Quantity: LF As built : 0 Barrier Handrail diameter (OD) or gripping surface not between 1 1/4" to 2" or non circular 4" 4.8" 3 1/4" inner handrail grip diameter Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2E Location: Floor 1 Stairway S0101 Stairways Contrasting Color ADA 2010 ADAS Advisory Performance Standard: Yes Quantity: LF or TR As built : 48 Barrier No contrasting color on each tread of interior stairway Treads lack contrasting color defined as 70% contrast Rec. Solution: Recommended: Consider providing contrasting color on each tread Barrier Severity: 2 Recommended Cost Est $1, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

29 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2F Location: X Coordinate: Floor 1 Stairway S0101 Stairways Surface Condition Existing 2010 ADAS Performance Standard: No Quantity: SF Barrier Stairway surface is not slip resistant As built : 124 Slip resistant surface could not be verified Rec. Solution: Provide non slip tread surface Barrier Severity: 4 Low Severity Cost Est $31, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 2G Location: Floor 1 Stairway S0101 Stairways Vertical Access Elevator 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier No form of vertical access provided at stairway to reach upper floors No accessible vertical access provided Rec. Solution: Provide a passenger elevator to reach upper floors Barrier Severity: 1 Necessary Cost Est $1,250, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

30 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3A Location: X Coordinate: Floor 1 Women's Restroom 104A Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible tactile sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3B Location: Floor 1 Women's Restroom 104A Restrooms Sign ISA at Accessible Restroom 2010 ADAS Barrier No ISA symbol on wall sign posted at accessible toilet room No sign provided to indicate that room is accessible Rec. Solution: Provide ISA symbol on restroom wall sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Provide ISA sign when restroom is remodeled to provide wheelchair access ADA Assessment and Survey

31 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3C Location: X Coordinate: Floor 1 Women's Restroom 104A Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 13 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3D Location: Floor 1 Women's Restroom 104A Restrooms Door Closer Sweep 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 4 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

32 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3E Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Door Clearance Pull Side 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door lacks min. 18" strike edge clearance at pull side 7 1/12" strike edge clearance to trash bin Rec. Solution: Provide automatic door opening device and remove trash bin Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3F Location: Floor 1 Women's Restroom 104A Restrooms Protruding Object Wall mounted 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Object protrudes more than 4" into circulation path Mirror shelf protrudes 5" at 39 1/2" high and paper towel dispenser protrudes 10" at 45" high Rec. Solution: Remove objects or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

33 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3G Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Lavatory Rim Height 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Lavatory rim or counter edge is higher than 34" AFF 36 1/2" high AFF Rec. Solution: Provide min. 1 accessible lavatory Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: 2 of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3H Location: Floor 1 Women's Restroom 104A Restrooms Lavatory Depth 2010 ADAS & 306 Performance Standard: No Quantity: JOB As built : 0 Barrier Lavatory lacks min. 17" in horizontal depth measured from back wall 16 3/4" deep to wall Rec. Solution: Provide min. 1 accessible lavatory Barrier Severity: 3 Hindrance Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

34 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3I Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Lavatory Surfaces 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Lavatory has sharp or abrasive surfaces on edge, rim or apron Lavatories have abrasive surfaces on bottom side Rec. Solution: Provide min. 1 accessible lavatory Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3J Location: Floor 1 Women's Restroom 104A Restrooms Lavatory Drainpipes 2010 ADAS Barrier Hot water and drainpipes accessible under lavatory not insulated or covered No insulation provided Rec. Solution: Insulate drainpipes and hot water pipes Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

35 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3K Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Mirror 2010 ADAS Barrier Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface Mirror with shelf 40 1/2" high Rec. Solution: Replace or remount mirror Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3L Location: Floor 1 Women's Restroom 104A Restrooms Dispensers Forward Approach 2010 ADAS Performance Standard: Barrier No Quantity: JOB As built : 1 Where the reach depth exceeds 20" but is less than 25" deep, the high forward reach exceeds 44" high Soap dispenser 45" high and 11 1/2" deep over lavatory 36 1/2" high Rec. Solution: Relocate dispenser to location within reach range or provide additional dispenser Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

36 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3M Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Stall Door Closer 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Stall door not equipped with an automatic closing device Door does not self close Rec. Solution: Replace compartment hinge with adjustable mechanism Barrier Severity: 2 Recommended Cost Est $1, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3N Location: Floor 1 Women's Restroom 104A Restrooms Toilet Stall Door Hardware 2010 ADAS Barrier Inside of compartment door lacks a loop or U pull below latch No U pull provided Rec. Solution: Provide hardware Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

37 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3O Location: X Coordinate: Barrier Floor 1 Women's Restroom 104A Restrooms Performance Standard: Stall Door Hardware 2010 ADAS No Quantity: EACH As built : 1 Stall door hardware involves tight grasping/pinching to close and no U pull provided Door lock not fist operable and seems to not work Rec. Solution: Provide U pull hardware on outside and inside of stall door Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3P Location: Floor 1 Women's Restroom 104A Restrooms Toilet Rear Grab Bar 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Rear grab bar not centered 12" from wall and 24" on the other side of WC Rear grab bar extends 6" from toilet centerline Rec. Solution: Technically infeasible due to structural elements (pipes) Barrier Severity: 5 Technically Infea Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

38 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3Q Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Toilet Side Grab Bar 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Side grab bar does not extend min. 54" from rear wall Side grab bar extends 51 1/2" from rear wall Rec. Solution: Replace grab bars with reinforcement Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3R Location: Floor 1 Women's Restroom 104A Restrooms Toilet Seat Height 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Water closet seat not between 17" to 19" high 19 1/2" high Rec. Solution: Provide min. 1 accessible water closet Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

39 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3S Location: X Coordinate: Barrier Floor 1 Women's Restroom 104A Restrooms Performance Standard: Toilet Centerline 2010 ADAS No Quantity: JOB As built : 0 Water closet centerline not between 16" and 18" O. C. 19" on center Rec. Solution: Relocate water closet Barrier Severity: 3 Hindrance Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3T Location: Floor 1 Women's Restroom 104A Restrooms Toilet Paper Dispenser 2010 ADAS Barrier Toilet tissue dispenser not within 7" to 9" from front edge of toilet Dual unit; both rolls are not 7" 9" from front of toilet Rec. Solution: Reposition or replace toilet paper dispenser Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

40 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3U Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Seat Cover Dispenser 2010 ADAS Barrier Seat cover dispenser not located on an accessible route. Blocked by water closet Access to dispenser blocked by water closet Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3V Location: Floor 1 Women's Restroom 104A Restrooms Shelves 2010 ADAS Barrier Shelf provided not mounted between 40" and 48" above floor or ground 64 3/4" high Rec. Solution: Provide additional shelf at accessible height Barrier Severity: 2 Recommended Cost Est $75.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

41 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3W Location: X Coordinate: Floor 1 Women's Restroom 104A Restrooms Protruding Object Wall mounted 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Object protrudes more than 4" into circulation path Shelf in stall protrudes 7 1/2" at 64 3/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Locker has U pull and lacks a locking device Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 3X Location: Floor 1 Women's Restroom 104A Restrooms Alarm Horn/Strobe 2010 ADAS Barrier Where a fire alarm is installed, no horn/strobe provided No device provided Rec. Solution: Provide horn/strobe in sanitary facility Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

42 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4A Location: X Coordinate: Floor 1 Vestibule V0105 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel Ramp threshold 3/8" high with no bevel Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4B Location: Floor 1 Vestibule V0105 Ramps Running Slope Existing (8.6% 8.9%) 2010 ADAS Performance Standard: No Quantity: LF As built : 30 Barrier Running slope exceeds 8.33% (8.6% 8.9%) 8.7% running slope Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 3 Hindrance Cost Est $6, ADA Assessment and Survey

43 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4C Location: X Coordinate: Floor 1 Vestibule V0105 Ramps Handrail 2010 ADAS Performance Standard: No Quantity: LF Barrier No handrail provided at both sides As built : 18 Ramp lacks handrail at both sides Rec. Solution: Replace handrails at both sides of ramp Barrier Severity: 1 Necessary Cost Est $4, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4D Location: Floor 1 Vestibule V0105 Doors or Gates Doormat 2010 ADAS & Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier Doormat not anchored to floor (possible trip hazard) Door mat not secured Rec. Solution: Secure exiting doormat or replace Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

44 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4E Location: X Coordinate: Floor 1 Vestibule V0105 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 1/2" high. Ramp blocks electrical switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 4F Location: Floor 1 Vestibule V0105 Alarms Horn/Strobe Corridor 2010 ADAS Performance Standard: No Quantity: EACH Barrier No horn/strobes in corridor As built : 1 No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

45 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5A Location: Floor 1 Men's Restroom 105 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5B Location: Floor 1 Men's Restroom 105 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 9 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

46 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5C Location: Floor 1 Men's Restroom 105 Doors or Gates Door Closer Interior Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period or does not stop 5" from door frame 4 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5D Location: Floor 1 Men's Restroom 105 Doors or Gates Headroom Existing 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door clearance not min. 80" high As built : /4" high Rec. Solution: Replace door or gate Barrier Severity: 3 Hindrance Cost Est $1, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

47 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5E Location: Floor 1 Men's Restroom 105 Restrooms Dispensers Protruding Object 2010 ADAS Barrier Protruding dispenser creates protruding hazard in path of travel Paper towel dispenser protrudes 10" at 40 1/2" high Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5F Location: Floor 1 Men's Restroom 105 Restrooms Protruding Object Wall mounted 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Object protrudes more than 4" into circulation path Mirror shelf protrudes 5 1/4" at 39" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

48 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5G Location: Floor 1 Men's Restroom 105 Restrooms Lavatory Depth 2010 ADAS & 306 Performance Standard: No Quantity: JOB As built : 1 Barrier Lavatory lacks min. 17" in horizontal depth measured from back wall 16 3/4" depth to back wall Rec. Solution: Provide min. 1 accessible lavatory Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5H Location: Floor 1 Men's Restroom 105 Restrooms Lavatory Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: JOB As built : 0 Barrier Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge 25" high knee clearance Rec. Solution: Provide min. 1 accessible lavatory Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

49 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5I Location: Floor 1 Men's Restroom 105 Restrooms Lavatory Drainpipes 2010 ADAS Barrier Hot water and drainpipes accessible under lavatory not insulated or covered No insulation provided Rec. Solution: Insulate drainpipes and hot water pipes Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5J Location: Floor 1 Men's Restroom 105 Restrooms Mirror 2010 ADAS Barrier Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface 40 3/4" high Rec. Solution: Replace or remount mirror Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

50 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5K Location: Floor 1 Men's Restroom 105 Barrier Restrooms Performance Standard: Dispensers Forward Approach 2010 ADAS No Quantity: JOB As built : 1 Where the reach depth exceeds 20" but is less than 25" deep, the high forward reach exceeds 44" high Soap dispensers 44" 45" high and 10 3/4" deep over lavatory obstruction 32 1/2" high Rec. Solution: Relocate dispenser to location within reach range or provide additional dispenser Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: 2 of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5L Location: Floor 1 Men's Restroom 105 Kitchens Sink Knee Clearance 2010 ADAS & Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided No accessible knee clearance at basin sink in toilet room Rec. Solution: Replace sink Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

51 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5M Location: Floor 1 Men's Restroom 105 Classrooms Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : /2" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5N Location: Floor 1 Men's Restroom 105 Classrooms Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided 20" high knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

52 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5O Location: Floor 1 Men's Restroom 105 Restrooms Lavatory Drainpipes 2010 ADAS Barrier Hot water and drainpipes accessible under lavatory not insulated or covered No insulation provided Rec. Solution: Insulate drainpipes and hot water pipes Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Basin Sink Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5P Location: Floor 1 Men's Restroom 105 Restrooms Lockers Control 2010 ADAS Barrier Locker mechanism not operable with fist or involves turning and grasping Mechanism not fist operable Rec. Solution: Provide min. 1 accessible locker or 5% overall Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: 12 lockers ADA Assessment and Survey

53 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5Q Location: Floor 1 Men's Restroom 105 Restrooms Floor Drain Existing 2010 ADAS Performance Standard: No Quantity: SF As built : 150 Barrier Floor drain located within clear floor space of fixture 6.9% slope Rec. Solution: Remodel drain inlet to have less than 1/2" lip Barrier Severity: 3 Hindrance Cost Est $37, Implementation Priority: 3 Implementation Phase: Floor immediately around drain also deteriorating Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5R Location: Floor 1 Men's Restroom 105 Restrooms Urinal Rim 2010 ADAS Performance Standard: No Quantity: JOB Barrier Urinal not max. 17" above the floor As built : /2" high rim at low urinal. Fixtures in space block needed clear floor space Rec. Solution: Provide min. 1 accessible urinal Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: 30" deep clear floor space perpendicular to urinal ADA Assessment and Survey

54 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5S Location: Floor 1 Men's Restroom 105 Restrooms Urinal Rim 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Min. 1 urinal has no elongated rim projecting 14" to 17" from wall Rim projects 13 1/2" from wall Rec. Solution: Provide min. 1 accessible urinal Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5T Location: Floor 1 Men's Restroom 105 Restrooms Door Headroom 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door clearance not min. 80" high As built : 1 Bar over stall door 79 1/4" high Rec. Solution: Replace door and frame Barrier Severity: 2 Recommended Cost Est $1, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

55 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5U Location: Floor 1 Men's Restroom 105 Restrooms Stall Door Closer 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Stall door not equipped with an automatic closing device Stall door not fully self closing Rec. Solution: Replace compartment hinge with adjustable mechanism Barrier Severity: 2 Recommended Cost Est $1, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5V Location: Floor 1 Men's Restroom 105 Restrooms Toilet Stall Door Hardware 2010 ADAS Barrier Inside of compartment door lacks a loop or U pull below latch No U pull provided Rec. Solution: Provide hardware Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

56 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5W Location: Floor 1 Men's Restroom 105 Restrooms Toilet Rear Grab Bar 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Rear grab bar not mounted between 33" and 36" above floor 32 1/2" high Rec. Solution: Replace grab bars with reinforcement Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5X Location: Floor 1 Men's Restroom 105 Restrooms Toilet Rear Grab Bar 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Rear grab bar not centered 12" from wall and 24" on the other side of WC 4" to wall from toilet centerline Rec. Solution: No remediation recommended. Bar is longer than min. 24" and extends past 24" from centerlin Barrier Severity: 4 Low Severity Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

57 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5Y Location: Floor 1 Men's Restroom 105 Restrooms Toilet Grab Bars 2010 ADAS & Performance Standard: No Quantity: JOB As built : 1 Barrier Grab bars not secure or cannot bear min. 250 N of force Side grab bar mounted to stall partition Rec. Solution: Replace grab bars with reinforcement Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5Z Location: Floor 1 Men's Restroom 105 Restrooms Toilet Seat Height 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Water closet seat not between 17" to 19" high 19 1/2" high Rec. Solution: Provide min. 1 accessible water closet Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

58 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AA Location: Floor 1 Men's Restroom 105 Restrooms Toilet Paper Dispenser 2010 ADAS Barrier Toilet tissue dispenser not within 7" to 9" from front edge of toilet Both rolls of dual unit not within 7" 9" Rec. Solution: Reposition or replace toilet tissue dispenser Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AB Location: Floor 1 Men's Restroom 105 Restrooms Seat Cover Dispenser 2010 ADAS Barrier Seat cover dispenser not located on an accessible route. Blocked by water closet Access to dispenser blocked by toilet Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

59 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AC Location: Floor 1 Men's Restroom 105 Restrooms Protruding Object Wall mounted 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Object protrudes more than 4" into circulation path Shelves protrude 7 1/2" at 65" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AD Location: Floor 1 Men's Restroom 105 Restrooms Shelves 2010 ADAS Barrier Shelf provided not mounted between 40" and 48" above floor or ground 65 3/4" high Rec. Solution: Provide additional shelf at accessible height Barrier Severity: 2 Recommended Cost Est $75.00 Implementation Priority: 3 Implementation Phase: 2 of 2 ADA Assessment and Survey

60 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AE Location: Floor 1 Men's Restroom 105 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AF Location: Floor 1 Men's Restroom 105 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No tactile signage provided at door within public route on lab side of door Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

61 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AG Location: Floor 1 Men's Restroom 105 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 Bathroom door 12 lbf from lab Rec. Solution: Provide automatic door opening device or ISA directional sign leading to lobby entrance Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AH Location: Floor 1 Men's Restroom 105 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Bathroom hardware from lab door not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

62 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AI Location: Floor 1 Men's Restroom 105 Doors or Gates Hardware Location 2010 ADAS Barrier Hardware not located between 34" and 48" above ground/floor Bathroom side handle is at 30 1/2" high Rec. Solution: Remount new hardware at max. 48" high Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Lab side handle height is accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 5AJ Location: Floor 1 Men's Restroom 105 Doors or Gates Threshold Height exceeding 1/2" 2010 ADAS Barrier Door/Gate threshold exceeds 1/2" in height Step at bathroom door to lab has threshold 5" high Rec. Solution: Construct ramp to provide access or provide ISA directional sign to alternate entry Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

63 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6A Location: Floor 1 Lab Wet 110 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible signs Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: For rooms 110 and 108 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6B Location: Floor 1 Lab Wet 110 Signage ISA Directional Sign 2010 ADAS Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier No directional signage provided where accessible route diverges from main route Provide accessible sign Rec. Solution: Provide directional signage to other restroom door Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: There is a 5" step at the entrance to the restroom from the lab ADA Assessment and Survey

64 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6C Location: Floor 1 Lab Wet 110 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Door to hall has vision light at 53 3/4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6D Location: Floor 1 Lab Wet 110 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50" high. Shelving unit blocks switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

65 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6E Location: Floor 1 Lab Wet 110 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Fire extinguisher protrudes 5" at 35" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6F Location: Floor 1 Lab Wet 110 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Wood/metal shop equipment 36" 61" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ For band saw, belt sander, table saw, floor pulley, air tank, table vacuum ADA Assessment and Survey

66 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6G Location: Floor 1 Lab Wet 110 Controls and Mechanisms Lockers Ratio 2010 ADAS 803 Barrier No accessible locker provided in locker room No accessible lockers provided Rec. Solution: Provide min. 1 accessible locker or 5% overall Barrier Severity: 1 Necessary Cost Est $ lockers Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6H Location: Floor 1 Lab Wet 110 Controls and Mechanisms Lockers Control 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Locker mechanism not operable with fist or involves turning and grasping Mechanism not fist operable. Stored items block lockers clear floor space Rec. Solution: Provide min. 1 accessible locker or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

67 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6I Location: Floor 1 Lab Wet 110 Controls and Mechanisms Lockers Maneuvering Cl 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier No 60" maneuvering clearance provided at locker or bench No maneuvering clearance provided at locker Rec. Solution: Rearrange equipment/furniture to provide maneuvering space at accessible locker Barrier Severity: 2 Recommended Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6J Location: Floor 1 Lab Wet 110 Counters and Tables Table Surface Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Surface height exceeds 34" high As built : 1 34" 37 1/2" surface height. Stored items block tables clear floor space Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ tables. At least one or one of each type must be accessible ADA Assessment and Survey

68 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6K Location: Floor 1 Lab Wet 110 Counters and Tables Table Knee Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24 1/2" high knee clearance and 2" 5" deep knee clearance Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6L Location: Floor 1 Lab Wet 110 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block outlet clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

69 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6M Location: Floor 1 Lab Wet 110 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: May cause a tripping hazard. There are cords stretched across the ground in multiple places Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6N Location: Floor 1 Lab Wet 110 Clear Floor Space Passageway Min. 36" 2010 ADAS Performance Standard: No Quantity: LF As built : 100 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/ furniture to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $20, " 29" wide circulation route in many places around main workbench ADA Assessment and Survey

70 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6O Location: Floor 1 Lab Wet 110 Clear Floor Space Grate in Circulation Route 2010 ADAS 302 and Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" 1" openings in the grates throughout this room Rec. Solution: Replace grates Barrier Severity: 1 Necessary Cost Est $2, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6P Location: Floor 1 Lab Wet 110 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground 48" 69 1/2" high. Stored items block shelving units clear floor space Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $ shelves ADA Assessment and Survey

71 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6Q Location: Floor 1 Lab Wet 110 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Shelf protrudes 13 3/4" at 67 1/2" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6R Location: Floor 1 Lab Wet 110 Alarms Fire Pull 2010 ADAS Performance Standard: No Quantity: EACH Barrier Fire pull has no usable hardware As built : 1 Fire pull not fist operable Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $3, ADA Assessment and Survey

72 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6S Location: Floor 1 Lab Wet 110 Alarms Fire Pull 2010 ADAS Barrier Fire pulls not between 42" and 48" high 61 1/2" high. Stored objects and cabinet block fire pull clear floor space Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 6T Location: Floor 1 Lab Wet 110 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

73 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7A Location: X Coordinate: Floor 1 Workroom 106C Ramps Running Slope Existing (>9.5% or more) 2010 ADAS Performance Standard: No Quantity: LF As built : 18 Barrier Running slope exceeds 8.33% (>9.5% or more) 16.8% running slope Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 1 Necessary Cost Est $3, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7B Location: Floor 1 Workroom 106C Ramps Handrail 2010 ADAS Performance Standard: No Quantity: LF Barrier No handrail provided at both sides As built : 24 Ramp lacks handrail at both sides Rec. Solution: Replace handrails at both sides of ramp Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

74 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7C Location: X Coordinate: Floor 1 Workroom 106C Stairways Handrail Both Sides ADAAG 4.9.4* & 2010 ADAS Performance Standard: No Quantity: LF As built : 8 Barrier No handrail provided at both sides of stairway No handrail provided at both sides Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $1, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7D Location: Floor 1 Workroom 106C Stairways Contrasting Color ADA 2010 ADAS Advisory Performance Standard: Yes Quantity: LF or TR As built : 8 Barrier No contrasting color on each tread of interior stairway Treads lack contrasting color defined as 70% contrast Rec. Solution: Recommended: Consider providing contrasting color on each tread Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

75 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7E Location: X Coordinate: Floor 1 Workroom 106C Doors or Gates Door Closer Exterior Adjustment Performance Standard Performance Standard: Yes Quantity: EACH Barrier Door opening force exceeds 8.5 lbf As built : 1 Exterior door 16 lbf Rec. Solution: Replace or adjust existing closer Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7F Location: Floor 1 Workroom 106C Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period Exterior door 4 second sweep Rec. Solution: Replace or adjust existing closer Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

76 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7G Location: X Coordinate: Floor 1 Workroom 106C Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Exterior door hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7H Location: Floor 1 Workroom 106C Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Entrance door located in front of accessible parking stall. ISA directional sign should be posted at door or door should be made accessible ADA Assessment and Survey

77 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 7I Location: X Coordinate: Floor 1 Workroom 106C Signage Tactile Exit Signs Door 2010 ADAS Barrier Ground floor doors that exit to exterior lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT at exit side of door Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8A Location: Floor 1 Thermal/Fluid Sciences Lab 106 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

78 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8B Location: Floor 1 Thermal/Fluid Sciences Lab 106 Doors or Gates Door Closer Interior Sweep Period 2010 ADAS Barrier Door closer lacks min. 5 second sweep period or does not stop 5" from door frame 4 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8C Location: Floor 1 Thermal/Fluid Sciences Lab 106 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 1/2" 50" high. Stored item blocks switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches ADA Assessment and Survey

79 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8D Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 10 Barrier Change in level greater than 1/2" in clear floor space Grate in clear floor space with >1/2" slits Rec. Solution: Repair trip hazard. Remodel where needed Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8E Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS Performance Standard: No Quantity: SF As built : 10 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 51" turning space by wooden counter Rec. Solution: Rearrange equipment/ furniture or remodel to provide wheelchair access Barrier Severity: 2 Recommended Cost Est $1, /2" 30 1/2" wide circulation route between apparatus and doors (when closed), cables, chair ADA Assessment and Survey

80 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8F Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Workstation Ratio 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 6 Barrier At least 1 workstations or 5% of all workstations is not accessible Min. 1 workstation not accessible Rec. Solution: One workstation of each type must be accessible Barrier Severity: 3 Hindrance Cost Est $5, Balance workstation, workstation over dark cabinets, computer workstation, low workstation, workstation with white counter and workstation on wheels Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8G Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Workstation surface height exceeds 34" high 47 1/2" high workstation surface Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

81 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8H Location: Floor 1 Thermal/Fluid Sciences Lab 106 Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Balance 47 1/2" 51 1/4" high and 2 3/4" 15 1/2" deep over surface obstruction 47 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8I Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Counter Surface Height 2010 ADAS Barrier No section at least 3 feet long between 28" and 34" provided at existing counter 40" high and blocked by furniture, etc. Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

82 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8J Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Workstation surface height exceeds 34" high 36" high workstation surface at PC workstation Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8K Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided No knee clearance Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ " deep knee clearance when high shelf is extended ADA Assessment and Survey

83 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8L Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Extended shelf protrudes 12" at 27" high. Fire extinguisher protrudes 4 1/2" at 33" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: If left extended Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8M Location: Floor 1 Thermal/Fluid Sciences Lab 106 Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided 22 3/4" high and 6 3/4" deep knee clearance. Computer workstation blocks low workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 Low workstation ADA Assessment and Survey

84 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8N Location: Floor 1 Thermal/Fluid Sciences Lab 106 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Ear plug dispenser control 52 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8O Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Ear plugs dispenser protrudes 6" at 54 1/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

85 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8P Location: Floor 1 Thermal/Fluid Sciences Lab 106 Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 37 1/2" 45 1/4" high and 0" 24 1/2" deep over surface obstruction 37 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ For demodulator, multi meter, power strip, experiment apparatus controls Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8Q Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 40 Barrier Change in level greater than 1/2" in clear floor space 28.1% ramp between rooms at sliding door threshold Rec. Solution: Construct accessible ramp. Remodel where needed Barrier Severity: 1 Necessary Cost Est $23, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

86 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8R Location: Floor 1 Thermal/Fluid Sciences Lab 106 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Multiple power cords on the ground Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 8S Location: Floor 1 Thermal/Fluid Sciences Lab 106 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

87 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9A Location: X Coordinate: Floor 1 Lab Wet 106B Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9B Location: Floor 1 Lab Wet 106B Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

88 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9C Location: X Coordinate: Floor 1 Lab Wet 106B Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, View panel located 49" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9D Location: Floor 1 Lab Wet 106B Counters and Tables Workstation Ratio 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 6 Barrier At least 1 workstations or 5% of all workstations is not accessible Min. 1 workstation not accessible Rec. Solution: One workstation of each type must be accessible Barrier Severity: 3 Hindrance Cost Est $5, For workstation on wheels, workstation without sink, Blue device computer workstation, workstation with sink, computer workstation near sink and workstation behind sheet metal ADA Assessment and Survey

89 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9E Location: X Coordinate: Floor 1 Lab Wet 106B Clear Floor Space Grate in Circulation Route 2010 ADAS 302 and 303 Performance Standard: No Quantity: EACH As built : 60 Barrier Grate in pedestrian route has openings that exceed 1/2" Slits in floor 1" wide over the entire space Rec. Solution: Replace flooring Barrier Severity: 1 Necessary Cost Est $15, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9F Location: Floor 1 Lab Wet 106B Counters and Tables Counter Surface Height 2010 ADAS Performance Standard: No Quantity: EACH As built : 3 Barrier No section at least 3 feet long between 28" and 34" provided at existing counter 36 1/2" high workstation surface Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high for each type of work counter Barrier Severity: 3 Hindrance Cost Est $2, ADA Assessment and Survey

90 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9G Location: X Coordinate: Floor 1 Lab Wet 106B Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 41" 74 1/2" high and 0" 27" deep over surface obstruction 36 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ For oscilloscope, power strip, fluid control devices, experiment apparatus, multi meter, power supply, strobe Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9H Location: Floor 1 Lab Wet 106B Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Ear plug container 62 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

91 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9I Location: X Coordinate: Floor 1 Lab Wet 106B Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Ear plug container protrudes 6" at 58" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9J Location: Floor 1 Lab Wet 106B Controls and Mechanisms Electrical Outlets Forward Reach Obstructed ( 10") 2010 ADAS Barrier Outlet located over an obstruction max. 34" high located above 48" 49" high and 30" deep over counter 35 1/2" high Rec. Solution: Relocate control or mechanism to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

92 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9K Location: X Coordinate: Floor 1 Lab Wet 106B Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided 24 1/2" high knee clearance at PC control station Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9L Location: Floor 1 Lab Wet 106B Clear Floor Space Passageway Min. 36" 2010 ADAS Performance Standard: No Quantity: LF As built : 0 Barrier Circulation route not min. 36" wide between elements 4" 27" wide circulation route between device and workstation Rec. Solution: Rearrange equipment/ furniture to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

93 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9M Location: X Coordinate: Floor 1 Lab Wet 106B Classrooms Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /4" high. Workstation blocks sink clear floor space Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9N Location: Floor 1 Lab Wet 106B Classrooms Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : /2" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

94 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9O Location: X Coordinate: Floor 1 Lab Wet 106B Classrooms Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9P Location: Floor 1 Lab Wet 106B Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10") 2010 ADAS Barrier Control or mechanism over an obstruction max. 34" high located above 48" Soap dispenser 47 3/4" high and 26" deep over an obstruction 35 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

95 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9Q Location: X Coordinate: Floor 1 Lab Wet 106B Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Workstation surface height exceeds 34" high 37" high workstation surface. Workstation with sink blocks workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9R Location: Floor 1 Lab Wet 106B Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided No knee clearance Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

96 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9S Location: X Coordinate: Floor 1 Lab Wet 106B Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Computer power strip 4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9T Location: Floor 1 Lab Wet 106B Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Barrier Workstation surface height exceeds 34" high 37" high workstation surface. Sheet metal blocks workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

97 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9U Location: X Coordinate: Floor 1 Lab Wet 106B Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground 72" high. Chairs block cabinet clear floor space Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 9V Location: Floor 1 Lab Wet 106B Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

98 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10A Location: X Coordinate: Floor 1 Senior Project Cage 10/ Lab 110D Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10B Location: Floor 1 Senior Project Cage 10/ Lab 110D Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

99 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10C Location: X Coordinate: Floor 1 Senior Project Cage 10/ Lab 110D Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10D Location: Floor 1 Senior Project Cage 10/ Lab 110D Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 50" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

100 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10E Location: X Coordinate: Floor 1 Senior Project Cage 10/ Lab 110D Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Safety switch box protrudes 5 1/2" at 60 3/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10F Location: Floor 1 Senior Project Cage 10/ Lab 110D Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 27" perpendicular to door to table Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

101 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10G Location: X Coordinate: Floor 1 Senior Project Cage 10/ Lab 110D Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 15 3/4" 24" high knee clearance Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10H Location: Floor 1 Senior Project Cage 10/ Lab 110D Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route ADA Assessment and Survey

102 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 10I Location: X Coordinate: Floor 1 Senior Project Cage 10/ Lab 110D Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11A Location: Floor 1 Senior Project Cage 9/ Lab 110C Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

103 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11B Location: X Coordinate: Floor 1 Senior Project Cage 9/ Lab 110C Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11C Location: Floor 1 Senior Project Cage 9/ Lab 110C Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

104 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11D Location: X Coordinate: Floor 1 Senior Project Cage 9/ Lab 110C Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 56" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11E Location: Floor 1 Senior Project Cage 9/ Lab 110C Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 6" perpendicular to door Rec. Solution: Remove stored items Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

105 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11F Location: X Coordinate: Floor 1 Senior Project Cage 9/ Lab 110C Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11G Location: Floor 1 Senior Project Cage 9/ Lab 110C Clear Floor Space Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, ADA Assessment and Survey

106 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11H Location: X Coordinate: Floor 1 Senior Project Cage 9/ Lab 110C Counters and Tables Desk Clear Floor Space 2010 ADAS Barrier Clear floor space 30" x 48" not provided at desk Stored items block desk clear floor space Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ Knee clearance okay Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11I Location: Floor 1 Senior Project Cage 9/ Lab 110C Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block shelf clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

107 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 11J Location: X Coordinate: Floor 1 Senior Project Cage 9/ Lab 110C Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12A Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

108 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12B Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12C Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

109 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12D Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Doors or Gates Front App/pull 60" Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 10" strike edge clearance to bookcase Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12E Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 57" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

110 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12F Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 3" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12G Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route ADA Assessment and Survey

111 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12H Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Clear Floor Space Grate in Circulation Route 2010 ADAS 302 and 303 Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12I Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block outlet clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

112 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12J Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Safety switch box protrudes 5" at 74 1/2" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12K Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block table saw and shelf clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

113 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12L Location: X Coordinate: Floor 1 Senior Project Cage 8 / Lab Ind 110B Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26 1/2" high knee clearance. Table saw and stored items block table clear floor space Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 12M Location: Floor 1 Senior Project Cage 8 / Lab Ind 110B Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

114 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13A Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13B Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

115 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13C Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13D Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer No strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Push side to stored items ADA Assessment and Survey

116 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13E Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 2 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route. 21 3/4" 29" wide passageway to table Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13F Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Carts block whiteboard clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

117 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13G Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible. Provide assistance Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Shelves 42" 79" high and 17" deep over counter obstruction 35 1/2" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13H Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Counters and Tables Counter Surface Height 2010 ADAS Barrier No section at least 3 feet long between 28" and 34" provided at existing counter 35 1/2" high Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

118 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13I Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Counters and Tables Counter Knee Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 5" knee clearance Rec. Solution: Replace counter. Flip up counters, adjacent tables and similar devices not permitted Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13J Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide No knee clearance Rec. Solution: Move stored objects Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

119 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13K Location: X Coordinate: Floor 1 Senior Project Cage 7 / Lab Ind 110A Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Carts block outlets clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 13L Location: Floor 1 Senior Project Cage 7 / Lab Ind 110A Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

120 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14A Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14B Location: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

121 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14C Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Threshold Height exceeding 1/2" 2010 ADAS Barrier Door/Gate threshold exceeds 1/2" in height 3/4" gap at threshold Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14D Location: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Doormat 2010 ADAS & Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier Doormat not anchored to floor (possible trip hazard) Door mat not secured Rec. Solution: Secure exiting doormat or replace Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

122 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14E Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 33" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14F Location: Floor 1 MIME Composite Materials Lab Stairs Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 57 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

123 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14G Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Stairways Handrail Both Sides ADAAG 4.9.4* & 2010 ADAS Performance Standard: No Quantity: LF As built : 14 Barrier No handrail provided at both sides of stairway No handrail provided at wall side Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $3, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14H Location: Floor 1 MIME Composite Materials Lab Stairs Stairways Handrail Extension Bottom 2010 ADAS Performance Standard: No Quantity: LF As built : 0 Barrier Extension not sloped for length of one tread beyond the last riser nosing No bottom handrail extension Rec. Solution: Provide handrails at both sides of stairway Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

124 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14I Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Stairways Contrasting Color ADA 2010 ADAS Advisory Performance Standard: Yes Quantity: LF or TR As built : 16 Barrier No contrasting color on each tread of interior stairway Treads lack contrasting color defined as 70% contrast Rec. Solution: Recommended: Consider providing contrasting color on each tread Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14J Location: Floor 1 MIME Composite Materials Lab Stairs Stairways Surface Condition Existing 2010 ADAS Performance Standard: No Quantity: SF Barrier Stairway surface is not slip resistant As built : 18 Slip resistant surface could not be verified Rec. Solution: Provide slip resistant surface Barrier Severity: 4 Low Severity Cost Est $4, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

125 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14K Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block stairway landing clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14L Location: Floor 1 MIME Composite Materials Lab Stairs Ramps Ramp Landing Existing (>5.0% or more) 2010 ADAS Performance Standard: No Quantity: LF Barrier Landing is not level (>5.0% or more) As built : % for 2" at its steepest; 7.9% average for 5 1/2" Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 1 Necessary Cost Est $4, Implementation Priority: 1 Implementation Phase: Ramp to lift ADA Assessment and Survey

126 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14M Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 0 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 8 3/4" strike edge clearance from lift door to wall Rec. Solution: Remodel to provide accessible strike edge clearance Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14N Location: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door No maneuvering clearance provided perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Stored items in door swing ADA Assessment and Survey

127 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14O Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Stairways Vertical Access Lift 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier No form of vertical access provided at stairway to reach upper floors The lift travels vertically 3 feet Rec. Solution: Repair or replace existing pit under lift Barrier Severity: 1 Necessary Cost Est $16, Implementation Priority: 1 Implementation Phase: Dimensions: 45" x 60", debris under lift prevents it from fully landing Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14P Location: Floor 1 MIME Composite Materials Lab Stairs Ramps Ramp Landing Existing (>5.0% or more) 2010 ADAS Performance Standard: No Quantity: LF Barrier Landing is not level (>5.0% or more) As built : 0 Bottom ramp 14 1/4" long at 25.8%. Table blocks ramp clear floor space Rec. Solution: Construct a pit for lift to ensure level landing Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

128 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14Q Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Elevators Car Control Buttons Location 2010 ADAS & Barrier Car control buttons located above 48" from finish floor measured at the centerline Upper level call buttons 41 1/2" high. Stored item block upper level call buttons clear floor space Rec. Solution: Replace control panel Barrier Severity: 1 Necessary Cost Est $2, Implementation Priority: 1 Implementation Phase: Lift call buttons do not work Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14R Location: Floor 1 MIME Composite Materials Lab Stairs Elevators Car Control Buttons Location 2010 ADAS & Performance Standard: No Quantity: EACH As built : 0 Barrier Car control buttons located above 48" from finish floor measured at the centerline Lower level call buttons 42" high, 28 1/2" deep, over refrigerator 35" high. Table blocks lower level call buttons clear floor space Rec. Solution: Replace control panel Barrier Severity: 1 Necessary Cost Est $0.00 Implementation Priority: 1 Implementation Phase: Lift call buttons do not work ADA Assessment and Survey

129 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 14S Location: X Coordinate: Floor 1 MIME Composite Materials Lab Stairs Doors or Gates Automatic Doors Timing 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Door does not remain open for at least 6 seconds Auto door opener for lift repeatedly opens multiple times automatically Rec. Solution: Repair actuation device Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15A Location: Floor 1 MIME Composite Materials Lab 107 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

130 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15B Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 56 1/2" high. Lift blocks switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15C Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Material rolls 68" high. Wood blocks material roll clear floor space Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

131 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15D Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Trash bin blocks metal material clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15E Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Cabinet not accessible. Trash bin blocks cabinet clear floor space Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

132 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15F Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 30 Barrier Change in level greater than 1/2" in clear floor space 5 1/2" step into the freezer. Materials block walk in freezer clear floor space Rec. Solution: Construct a ramp to provide access. Remodel where needed Barrier Severity: 1 Necessary Cost Est $17, Implementation Priority: 1 Implementation Phase: Walk in freezer. Same barriers identifed at chest freezer Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15G Location: Floor 1 MIME Composite Materials Lab 107 Restrooms Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 20 Barrier Grate in pedestrian route has openings that exceed 1/2" 1" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

133 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15H Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 2 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover in freezer and on work floor Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Facility Function: Public Status: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15I Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Protruding Object 2010 ADAS 307 Performance Standard: No Quantity: EACH As built : 2 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Electrical control box protrudes 5" at 51" high. Safety switch box protrudes 5 3/4" at 59" high Rec. Solution: Provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

134 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15J Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Safety switch controls 59" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15K Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Electrical Outlets Hi/Low Reach 2010 ADAS Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 66" high. Table blocks outlet clear floor space Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

135 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15L Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Table blocks shelf clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15M Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Actuator/Control Fist Operable 2010 ADAS Barrier Control or mechanism not usable with a closed fist Cabinet not fist operable. Table blocks flammable liquid storage cabinet clear floor space Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

136 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15N Location: Floor 1 MIME Composite Materials Lab 107 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Safety switch 70" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15O Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Safety switch protrudes 7 1/2" at 53" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

137 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15P Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Valve protrudes 11" at 60 1/2" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15Q Location: Floor 1 MIME Composite Materials Lab 107 Counters and Tables Table Protruding Hazard 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Table creates protruding hazard in accessible route Two tables create protrusions 14" at 27 1/2" high. Other table blocks table clear floor space Rec. Solution: Remove table or provide detectable warning for the visually impaired Barrier Severity: 2 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

138 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15R Location: Floor 1 MIME Composite Materials Lab 107 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide No knee clearance at cabinet. Other table blocks table by desk clear floor space Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ Table 30" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15S Location: Floor 1 MIME Composite Materials Lab 107 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26 1/2" knee clearance at table by desk Rec. Solution: Provide min. 1 accessible table or one of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

139 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15T Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 2 Barrier Circulation route not min. 36" wide between elements 12" wide passageway between trash bin and whiteboard to desk. 24" 31" wide circulation route Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15U Location: Floor 1 MIME Composite Materials Lab 107 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24 1/4" high knee clearance Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

140 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15V Location: Floor 1 MIME Composite Materials Lab 107 Counters and Tables Desk Toe Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Toe clearance is not min. 9" high or does not extend between 17" and 25" deep No toe clearance to cables Rec. Solution: Provide cable cover Barrier Severity: 3 Hindrance Cost Est $75.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15W Location: Floor 1 MIME Composite Materials Lab 107 Clear Floor Space Carpet/Rug 2010 ADAS Performance Standard: No Quantity: EACH As built : 4 Barrier Carpet/rug not anchored to floor (possible trip hazard) Floor mats present tripping hazard Rec. Solution: Secure exiting carpet/rug or replace Barrier Severity: 1 Necessary Cost Est $2, ADA Assessment and Survey

141 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 15X Location: Floor 1 MIME Composite Materials Lab 107 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16A Location: Floor 1 Senior Project Cage 6/ Lab 110E Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

142 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16B Location: X Coordinate: Floor 1 Senior Project Cage 6/ Lab 110E Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16C Location: Floor 1 Senior Project Cage 6/ Lab 110E Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

143 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16D Location: X Coordinate: Floor 1 Senior Project Cage 6/ Lab 110E Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 59 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16E Location: Floor 1 Senior Project Cage 6/ Lab 110E Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 3" strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Push side to stored items ADA Assessment and Survey

144 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16F Location: X Coordinate: Floor 1 Senior Project Cage 6/ Lab 110E Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 6" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door to shop vacuum Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16G Location: Floor 1 Senior Project Cage 6/ Lab 110E Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route ADA Assessment and Survey

145 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16H Location: X Coordinate: Floor 1 Senior Project Cage 6/ Lab 110E Clear Floor Space Grate in Circulation Route 2010 ADAS Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16I Location: Floor 1 Senior Project Cage 6/ Lab 110E Counters and Tables Desk Surface Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Surface height exceeds 34" high As built : 1 37" surface height. Fixtures block desk clear floor space Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

146 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16J Location: X Coordinate: Floor 1 Senior Project Cage 6/ Lab 110E Controls and Mechanisms Electrical Outlets Side Reach Obstructed (10" 24") 2010 ADAS Barrier Outlet located over an 10" to 24" obstruction max. 34" high located above 46" 65" high over an obstruction 37" high. Desk blocks outlet clear floor space Rec. Solution: Relocate control or mechanism to max. 46" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 16K Location: Floor 1 Senior Project Cage 6/ Lab 110E Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

147 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17A Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17B Location: Floor 1 Senior Project Cage 5/ Lab 110F Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

148 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17C Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17D Location: Floor 1 Senior Project Cage 5/ Lab 110F Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 55 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

149 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17E Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side No strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Pull to stored items Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17F Location: Floor 1 Senior Project Cage 5/ Lab 110F Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer No strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Push and 5" perpendicular to stored items ADA Assessment and Survey

150 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17G Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Cabinet blocks outlet clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17H Location: Floor 1 Senior Project Cage 5/ Lab 110F Clear Floor Space Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, ADA Assessment and Survey

151 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17I Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 2 Barrier Circulation route not min. 36" wide between elements Stored items do not allow an accessible route. 28 3/4" wide passageway to desk Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17J Location: Floor 1 Senior Project Cage 5/ Lab 110F Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24 1/4" high knee clearance Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

152 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17K Location: X Coordinate: Floor 1 Senior Project Cage 5/ Lab 110F Counters and Tables Desk Toe Clearance 2010 ADAS Barrier Toe clearance is not min. 9" high or does not extend between 17" and 25" deep Toe clearance reduced by cables Rec. Solution: Provide cable cover Barrier Severity: 3 Hindrance Cost Est $75.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 17L Location: Floor 1 Senior Project Cage 5/ Lab 110F Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

153 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18A Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18B Location: Floor 1 Senior Project Cage 4/ Lab 110G Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

154 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18C Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18D Location: Floor 1 Senior Project Cage 4/ Lab 110G Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 57" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

155 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18E Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Doors or Gates Front App/pull 60" Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 51" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door to stored items. 5" strike edge clearance pull Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18F Location: Floor 1 Senior Project Cage 4/ Lab 110G Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door No maneuvering clearance provided perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door to stored items. 7" strike edge clearance push ADA Assessment and Survey

156 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18G Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Controls and Mechanisms Actuator/Control Fist Operable 2010 ADAS Barrier Control or mechanism not usable with a closed fist Valve not fist operable Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18H Location: Floor 1 Senior Project Cage 4/ Lab 110G Controls and Mechanisms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism not at min. 15" or max. 48" high Valve 56" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

157 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18I Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Valve protrudes 6" at 56" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18J Location: Floor 1 Senior Project Cage 4/ Lab 110G Clear Floor Space Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, ADA Assessment and Survey

158 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18K Location: X Coordinate: Floor 1 Senior Project Cage 4/ Lab 110G Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 18L Location: Floor 1 Senior Project Cage 4/ Lab 110G Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

159 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19A Location: X Coordinate: Floor 1 Senior Project Cage 3 / Lab Ind 110H Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19B Location: Floor 1 Senior Project Cage 3 / Lab Ind 110H Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

160 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19C Location: X Coordinate: Floor 1 Senior Project Cage 3 / Lab Ind 110H Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19D Location: Floor 1 Senior Project Cage 3 / Lab Ind 110H Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 55" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

161 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19E Location: X Coordinate: Floor 1 Senior Project Cage 3 / Lab Ind 110H Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door No maneuvering clearance provided perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door to stored items. 8 1/2" strike edge clearance push Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19F Location: Floor 1 Senior Project Cage 3 / Lab Ind 110H Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access. Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Stored items do not allow accessible route within space and cords on floor ADA Assessment and Survey

162 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19G Location: X Coordinate: Floor 1 Senior Project Cage 3 / Lab Ind 110H Counters and Tables Table Surface Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Surface height exceeds 34" high As built : /2" surface height Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19H Location: Floor 1 Senior Project Cage 3 / Lab Ind 110H Counters and Tables Table Knee Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 1 1/4" 4 3/4" deep knee clearance Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

163 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19I Location: X Coordinate: Floor 1 Senior Project Cage 3 / Lab Ind 110H Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block both shelving units clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 19J Location: Floor 1 Senior Project Cage 3 / Lab Ind 110H Clear Floor Space Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

164 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20A Location: Floor 1 SAE Project Cage 2 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20B Location: Floor 1 SAE Project Cage 2 Doors or Gates Hardware Operation 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

165 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20C Location: Floor 1 SAE Project Cage 2 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20D Location: Floor 1 SAE Project Cage 2 Doors or Gates Front App/pull 60" Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 2 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 14 1/2" 20" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door does not fully open either. 0" 4" strike edge clearance pull side ADA Assessment and Survey

166 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20E Location: Floor 1 SAE Project Cage 2 Doors or Gates Front App/push 48" 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 2 Barrier Door/Gate at push side with min. 18" lacks min. 48" perpendicular to door 4" perpendicular to door Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Door to stored items. 0" strike edge clearance push Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20F Location: Floor 1 SAE Project Cage 2 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route within this space ADA Assessment and Survey

167 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20G Location: Floor 1 SAE Project Cage 2 Clear Floor Space Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20H Location: Floor 1 SAE Project Cage 2 Controls and Mechanisms Actuator/Control Fist Operable 2010 ADAS Barrier Control or mechanism not usable with a closed fist Valve not fist operable Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

168 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20I Location: Floor 1 SAE Project Cage 2 Controls and Mechanisms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism not at min. 15" or max. 48" high Valve 60" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20J Location: Floor 1 SAE Project Cage 2 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Valve protrudes 6" at 60" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

169 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20K Location: Floor 1 SAE Project Cage 2 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block shelves clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ shelves Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 20L Location: Floor 1 SAE Project Cage 2 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

170 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21A Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Composites Post Processing Cage 110J Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21B Reference Dwg: 3 of 5 Location: Floor 1 Composites Post Processing Cage 110J Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not present Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

171 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21C Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Composites Post Processing Cage 110J Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21D Reference Dwg: 3 of 5 Location: Floor 1 Composites Post Processing Cage 110J Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 15" strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Pull side to box ADA Assessment and Survey

172 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21E Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Composites Post Processing Cage 110J Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 4" strike edge clearance Rec. Solution: Relocate door or gate to provide maneuvering clearance Barrier Severity: 1 Necessary Cost Est $2, Push side to wall Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21F Reference Dwg: 3 of 5 Location: Floor 1 Composites Post Processing Cage 110J Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible. Stored items block shelves clear floor space Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $ shelves ADA Assessment and Survey

173 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21G Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Composites Post Processing Cage 110J Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Stored items do not allow an accessible route within this space Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 21H Reference Dwg: 3 of 5 Location: Floor 1 Composites Post Processing Cage 110J Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

174 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22A Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Signage ISA Directional Sign 2010 ADAS Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier No directional signage provided where accessible route diverges from main route Accessible sign not provided at the exterior where a step leads to these entry doors Rec. Solution: Provide directional signage Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Provide ISA directional sign to South Entrance Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22B Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Doors or Gates Door Closer Exterior Adjustment Performance Standard Performance Standard: Yes Quantity: EACH Barrier Door opening force exceeds 8.5 lbf As built : lbf Rec. Solution: Replace or adjust existing closer Barrier Severity: 1 Necessary Cost Est $ Double doors. Provide ISA directional sign to south entrance ADA Assessment and Survey

175 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22C Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Door Closer Interior Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period or does not stop 5" from door frame 3 4 second sweep Rec. Solution: Replace closer Barrier Severity: 2 Recommended Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22D Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Doors or Gates Doormat 2010 ADAS & Advisory Performance Standard: Yes Quantity: EACH As built : 2 Barrier Doormat not anchored to floor (possible trip hazard) Doormats not secured Rec. Solution: Secure exiting doormats or replace Barrier Severity: 1 Necessary Cost Est $1, Door mats create tripping hazard ADA Assessment and Survey

176 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22E Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Sign Tactile Exit Sign at Door 2010 ADAS Barrier Ground floor doors that exit directly to the exterior lacks tactile exit sign Provide accessible sign Rec. Solution: Provide new sign stating EXIT at exiting side of door Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22F Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Corridors Passageway 36" Min. Width 2010 ADAS Performance Standard: Quantity: JOB As built : 20 Barrier Circulation route through corridor not min. 36" wide Small passageway to electrical box has a clear width of 25 1/4" between structural elements Rec. Solution: Remodel to provide access Barrier Severity: 1 Necessary Cost Est $4, ADA Assessment and Survey

177 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22G Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Protruding Object 2010 ADAS 307 Performance Standard: No Quantity: EACH As built : 2 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Fire extinguishers protrude 4 3/4" 6 1/2" at 30 3/4" 32 3/4" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22H Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Valve and handle protrude 4 1/2" at 61 1/4" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

178 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22I Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Restrooms Grate in Circulation Route 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier Grate in pedestrian route has openings that exceed 1/2" 1" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22J Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Controls and Mechanisms Electrical Outlets Hi/Low Reach 2010 ADAS & Performance Standard: No Quantity: LF As built : 1 Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 50 1/4" high Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high Barrier Severity: 2 Recommended Cost Est $ outlets ADA Assessment and Survey

179 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22K Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Sign Permanent Room/Space 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No sign with raised characters and Braille at permanent room or space with visual sign No accessible signs at rooms 100G and 102 Rec. Solution: Provide sign at latch side of entry door, where possible Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22L Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Corridors Fire Alarm Pull Actuator Operation 2010 ADAS Performance Standard: No Quantity: EACH Barrier Fire pull has no usable hardware As built : 1 Fire pull not fist operable Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $3, ADA Assessment and Survey

180 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22M Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Fire Alarm Pull Actuator Height 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Fire pulls not between 42" and 48" high 61 3/4" high Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22N Reference Dwg: 3 of 5 Location: Floor 1 Central Hallway H0100 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Electrical box protrudes 6" at 42 1/2" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

181 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 22O Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Central Hallway H0100 Corridors Horn/Strobe Device 2010 ADAS Barrier No horn or strobe in corridor where fire alarm exists in building No horn/strobe provided Rec. Solution: Provide horn/strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23A Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 5 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No tactile signage provided at door within public route Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 3 Implementation Phase: For rooms 100 (x2), 100A, 100B, 100D ADA Assessment and Survey

182 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23B Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : lbf Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door Barrier Severity: 1 Necessary Cost Est $5, West entry double doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23C Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 second sweep Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door Barrier Severity: 2 Recommended Cost Est $0.00 West entry ADA Assessment and Survey

183 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23D Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, West entry. 51 3/4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23E Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door 10" Bottom Surface Door Stop 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Door stop interrupts min. 10" smooth bottom surface Door stops at bottom of door can create trapping condition Rec. Solution: Remove door stop or other element at bottom of door at push side Barrier Severity: 1 Necessary Cost Est $ West entry ADA Assessment and Survey

184 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23F Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Signage Tactile Exit Signs Passage Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Exit thru an exit enclosure/exit passageway lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT ROUTE at exit side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: West entry Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23G Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

185 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23H Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Subzero machine 15" wide passageway Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23I Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Clear Floor Space 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Clear floor space of min. 30" by 48" not provided Stored items block computer and servovalve amplifier clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $0.00 Subzero machine workstation ADA Assessment and Survey

186 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23J Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation No knee clearance at Subzero machine workstation Rec. Solution: Provide min. 1 accessible workstation of each type or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23K Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Water valves protrudes 8 1/2" at 58 3/4" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: By Subzero machine workstation ADA Assessment and Survey

187 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23L Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation 24 19/4" high knee clearance at Asphalt workstation Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ Remove stored items in passage to table Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23M Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation 28 1/2" wide and 1" deep knee clearance at dual oven workstation by giant mixer Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 Stored items block workstation clear floor space. Work surface height 35" ADA Assessment and Survey

188 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23N Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Compressed air valves 66" 69" high and 49 1/2" deep over buckets 34 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23O Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Door Closer Automatic Device 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 15 lbf at walk in fridge Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

189 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23P Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Clear Width 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Clear width passage through door, sliding/folding door or gate is not min. 32" Door does not fully open Rec. Solution: Remove stored items Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23Q Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 5 Barrier Change in level greater than 1/2" in clear floor space 5" step to enter Rec. Solution: Construct accessible ramp Barrier Severity: 1 Necessary Cost Est $2, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

190 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23R Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 4" 72 1/2" high. Stored items block shelves clear floor space Rec. Solution: Provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 Inside large refrigerator Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23S Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 13" turning diameter inside large refrigerator Rec. Solution: Move stored items blocking maneuvering clearance Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

191 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23T Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36" workstation surface height. Stored items block balance workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ Balance workstation next to asphalt workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23U Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 Door closer broken Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Room 100D ADA Assessment and Survey

192 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23V Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Door Clearance Min. 18" at Pull Side 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door lacks min. 18" strike edge clearance at pull side 1 1/2" strike edge clearance Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $0.00 Room 100D Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23W Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 3/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Room 100D ADA Assessment and Survey

193 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23X Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Air valves 52" high and 20 1/2" deep over an obstruction 22" high. Green device on cart blocks air valves clear floor space Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Room 100D air valves over green device on cart Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23Y Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Passageway Min. 36" 2010 ADAS Performance Standard: No Quantity: LF As built : 0 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Remodel to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Room 100D dynamo drill; 29" wide circulation route to wall. Room 100D saw; 29" wide circulation route ADA Assessment and Survey

194 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23Z Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Room 100D Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AA Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Controls and display protrudes 11 1/2" at 48 1/4" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Climatic testing system ADA Assessment and Survey

195 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AB Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 21 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Climatic testing system; door does not have closer force needed to overcome pressure gradient Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AC Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 3" 66 3/4" high Rec. Solution: Provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 Climatic testing system. 3 shelves ADA Assessment and Survey

196 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AD Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 4 Barrier Circulation route not min. 36" wide between elements Climatic testing system; 15" 18" wide circulation route. Computer on shelf workstation; 16" wide circulation route Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Also, Balance counter to shelves; 9" wide circulation route. Computer on counter workstation; 18" wide circulation route Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AE Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 40 3/4" workstation surface height; Shelf block computer on shelf workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ Climatic testing system, computer on shelf workstation ADA Assessment and Survey

197 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AF Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36 3/4" workstation surface height. No knee clearance Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ Climatic testing system, computer on counter workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AG Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 4 3/4" 71 1/2" high Rec. Solution: Provide additional shelf/cabinet at accessible height or provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

198 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AH Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36" workstation surface height Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ Oven and soil tester workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AI Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 37" workstation surface height. Stored items block MTS stress tester and computer workstation Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ MTS stress tester and computer workstation ADA Assessment and Survey

199 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AJ Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed ( 10") 2010 ADAS Barrier Control or mechanism over an obstruction max. 34" high located above 48" 37 1/2" 72 1/2" high and 0" 10" deep over counter 37" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ MTS stress tester and computer workstation; for stress tester, signal controller, electrical display unit and computer Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AK Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36" workstation surface height Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ RTF controller workstation ADA Assessment and Survey

200 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AL Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 36 1/2" 60 1/2" high and 1 1/2" 29 1/2" deep over counter 36 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AM Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 34 1/2" workstation surface height Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $ Short workstation with two ovens ADA Assessment and Survey

201 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AN Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Controls and Mechanisms Electrical Outlets Side Reach Obstructed (10" 24") 2010 ADAS Barrier Outlet located over an 10" to 24" obstruction max. 34" high located above 46" 49 1/2" high and 22 1/4" deep over 36 1/2" high. Sink, workstation and stored items block outlet clear floor space Rec. Solution: Relocate control or mechanism to max. 46" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AO Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Non potable water valves 50 1/4" high and 22 1/4" deep over 36 1/2" high Rec. Solution: Relocate control or mechanism to max. 46" high Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

202 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AP Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /2" high. Workstation blocks sink clear floor space Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, Sink between workstations Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AQ Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : /2" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ Sink between workstations ADA Assessment and Survey

203 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AR Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided 10" deep knee clearance structural support Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Sink between workstations Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AS Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Sink Exposed Pipes 2010 ADAS Barrier Exposed hot water/drain pipes not insulated or configured so as to protect against contact No insulation provided Rec. Solution: Provide insulation at drain pipes Barrier Severity: 2 Recommended Cost Est $ Sink between workstations ADA Assessment and Survey

204 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AT Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Valves 44 1/2" high and 26 3/4" deep over sink 36 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Valves over sink between workstations Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AU Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Eye Wash Bubbler Height 2010 ADAS 308 Performance Standard: No Quantity: JOB Barrier Eye wash bubbler height not max. 36" As built : /2" counter height. Trash bins block eye wash clear floor space Rec. Solution: Reposition eye wash or provide additional eye wash for use in area Barrier Severity: 1 Necessary Cost Est $1, ADA Assessment and Survey

205 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AV Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Eye Wash Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 11" deep not provided 22 1/2" wide and 24 1/2" deep Rec. Solution: Remount eye wash Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AW Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 37" workstation surface height at workstation next to Forney machine Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

206 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AX Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 37" 56 1/2" high and 5 1/4" 31 1/2" deep over counter 37" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Workstation next to Forney machine; for balances (x2), DI water, outlets and other tools Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AY Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Floor Surface Slope 2010 ADAS 302 and 303 Performance Standard: No Quantity: SF Barrier Floor surface slope exceeds 2.0% As built : % slope and grate has openings of more than 1" Rec. Solution: Remodel to provide level clear floor space at controls/mechanisms Barrier Severity: 2 Necessary Cost Est $115, ADA Assessment and Survey

207 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23AZ Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Overhead door switch 49 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BA Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Clear Floor Space Controls 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 30" by 48" not provided Stored elements block light switch clear floor space Rec. Solution: Move stored items at control or mechanism Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

208 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BB Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Electrical box protrudes 11". Fire access panel protrudes 4 1/2" and fire extinguisher protrudes 4 1/2" Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BC Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Doors or Gates Door Closer Interior Adjustment 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : lbf Rec. Solution: Replace or adjust existing closer Barrier Severity: 1 Necessary Cost Est $ East entry. Provide ISA directional sign ADA Assessment and Survey

209 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BD Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Door Closer Sweep 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 3 4 second sweep Rec. Solution: Replace or adjust existing closer Barrier Severity: 1 Necessary Cost Est $0.00 East entry Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BE Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Doors Vision Lights 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, East entry. 49 1/2" high ADA Assessment and Survey

210 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BF Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Signage Tactile Exit Signs Passage Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Exit thru an exit enclosure/exit passageway lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT ROUTE at exit side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: East entry Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BG Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 39" high from floor. Stored items block whiteboard clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, By east entry ADA Assessment and Survey

211 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BH Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation No knee clearance at workstation with green legs Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BI Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Controls and Mechanisms Electrical Outlets Obsructed Reach ADA/ABA Barrier Use of outlet involves reach of more than 20" over an obstruction 38 1/2" high and 36" deep over an obstruction 34" high Rec. Solution: Relocate outlet to area with max. 20 reach Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

212 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BJ Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Vise grip protrudes 9 1/2" at 29 3/4" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BK Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Electrical box protrudes 6 1/4" at 40" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

213 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BL Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 44 1/2" high from floor Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BM Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36 1/2" workstation surface height at printer Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

214 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BN Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation No knee clearance Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BO Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 61 1/4" 90 1/4" high Rec. Solution: Provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

215 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BP Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36 1/4" workstation surface height Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BQ Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 36 19/4" 64" high and 0" 31" deep over counter 36 1/4" high Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Long workstation under shelving; for computer, vials, phone, outlets, experiment apparatus, SS detect machine, vacuum mixer, Corlock ADA Assessment and Survey

216 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BR Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 60 1/4" 100 1/2" high Rec. Solution: Provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 Long workstation under shelving Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BS Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Clear Floor Space Grate in Circulation Route 2010 ADAS 302 and 303 Performance Standard: No Quantity: EACH As built : 20 Barrier Grate in pedestrian route has openings that exceed 1/2" 1/2" 3/4" openings Rec. Solution: Replace grate Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

217 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 23BT Reference Dwg: 3 of 5 Location: Floor 1 Infrastructure Material Laboratory 100 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24A Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No tactile signage provided at door within public route Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

218 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24B Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 10 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24C Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Doors or Gates Door Closer Backcheck 2010 ADAS Performance Standard: Quantity: JOB As built : 0 Barrier Door closer does not stop at least 5" from door frame (no back check) Does does not stop 5" from close Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

219 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24D Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24E Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Doors or Gates Door 10" Bottom Surface Door Stop 2010 ADAS Barrier Door stop interrupts min. 10" smooth bottom surface Door stops at bottom of door can create trapping condition Rec. Solution: Remove door stop or other element at bottom of door at push side Barrier Severity: 1 Necessary Cost Est $75.00 ADA Assessment and Survey

220 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24F Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Doors or Gates Front App/pull 18" SEC Relocate Door 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 5 1/2" strike edge clearance to fixed counter Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24G Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer No strike edge clearance at push side to buckets Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

221 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24H Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space Hoses across the ground create a tripping hazard Rec. Solution: Provide cord cover or remove Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24I Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 36 1/2" workstation surface height. Stored items block side counter clear floor space Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

222 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24J Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation No knee clearance to stored items and cabinets Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24K Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Compressed air/vacuum valves 52 1/2" high and 23" deep over counter 36 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

223 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24L Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements No circulation route around middle island Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24M Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 37" workstation surface height. Stored items block far counter clear floor space Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

224 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24N Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation No knee clearance to stored items and cabinets Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $0.00 Far counter workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24O Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Burner 40" high and 22" deep over counter 37" high. Vise 44" high and 10" deep over counter 37" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Far counter workstation ADA Assessment and Survey

225 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24P Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Forward Reach Obstructed ( 10") 2010 ADAS Barrier Control or mechanism over an obstruction max. 34" high located above 48" Compressed air/vacuum valves 53" high and 23 1/2" deep over counter 37" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Far counter workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24Q Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS Performance Standard: No Quantity: SF As built : 100 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 44" turning space between counters Rec. Solution: Remodel area to provide min. 60" turning space Barrier Severity: 2 Recommended Cost Est $17, ADA Assessment and Survey

226 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24R Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 37 1/4" workstation surface height at L shaped workstation with sink Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 3 Hindrance Cost Est $ L shaped workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24S Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Compressed air/vacuum valves 54" high and 22 1/2" 26" deep over counter 37 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ L shaped workstation ADA Assessment and Survey

227 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24T Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Clear Floor Space Passageway Min. 36" 2010 ADAS Performance Standard: No Quantity: LF As built : 20 Barrier Circulation route not min. 36" wide between elements 29" passage between sink and counter Rec. Solution: Remodel to provide access Barrier Severity: 1 Necessary Cost Est $4, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24U Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Side Reach Obstructed (10" 24") 2010 ADAS Barrier Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46" Faucet controls are located 33 1/2" deep over an obstruction 37 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ L shaped workstation ADA Assessment and Survey

228 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24V Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /4" high. Fixtures block L shaped workstation sink clear floor space Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, L shaped workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24W Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : 1 12" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ L shaped workstation ADA Assessment and Survey

229 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24X Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 L shaped workstation Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24Y Reference Dwg: 3 of 5 Location: Floor 1 Dynamic Soils Laboratory Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Paper towel dispenser 55 3/4" high and 34" deep over sink 37 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ L shaped workstation ADA Assessment and Survey

230 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 24Z Reference Dwg: 3 of 5 Location: X Coordinate: Floor 1 Dynamic Soils Laboratory Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25A Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

231 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25B Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25C Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 3 4 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

232 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25D Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Doors or Gates Clear Width 2010 ADAS Barrier Clear width passage through door, sliding/folding door or gate is not min. 32" 27 1/4" clear width of single leaf of double doors Rec. Solution: Replace door or gate and frame to ensure that one active leaf provides min. 32" clear width Barrier Severity: 1 Necessary Cost Est $2, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25E Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $ /4" high ADA Assessment and Survey

233 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25F Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Doors or Gates Door 10" Bottom Surface Door Stop 2010 ADAS Barrier Door stop interrupts min. 10" smooth bottom surface Door stops at bottom of door can create trapping condition Rec. Solution: Remove door stop or other element at bottom of door at push side Barrier Severity: 1 Necessary Cost Est $75.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25G Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/2" 50 3/4" high. Mixer blocks switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches ADA Assessment and Survey

234 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25H Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 25 1/4" high and No knee clearance to stored items Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25I Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Classrooms Sink Faucet 2010 ADAS & 309 Performance Standard: Barrier No Quantity: EACH As built : 1 Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist Faucet not fist operable Rec. Solution: Replace faucet Barrier Severity: 1 Necessary Cost Est $ faucets ADA Assessment and Survey

235 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25J Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Classrooms Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : 3 37" high Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25K Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Classrooms Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : 1 6 3/4" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

236 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25L Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Classrooms Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25M Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Performance Standard: No Quantity: EACH As built : 3 Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Valves, fan and paper dispenser controls 40 1/2" 72" high and 15" 26" deep over counter obstruction 37" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $2, valves ADA Assessment and Survey

237 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25N Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Valves 55 1/2" 56 1/4" high, 26" 37" deep over 29 1/2" 36 1/4" obstruction Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Compressed air, vacuum and natural gas valves set Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25O Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Barrier Workstation surface height exceeds 34" high 37" high workstation surface at computer workstation Rec. Solution: Provide min. 1 accessible workstation at one of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

238 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25P Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided No knee clearance Rec. Solution: Provide min. 1 accessible workstation at one of each type Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25Q Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Counters and Tables Workstation Surface Max. 34" 2010 ADAS 902 Barrier Workstation surface height exceeds 34" high 37" high workstation surface Rec. Solution: Provide min. 1 accessible workstation at one of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

239 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25R Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Experiment controls and shear device 44" 54" high and 4 3/4" 17" deep over 37" counter Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 For experiment controls, shear device Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25S Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Controls and Mechanisms Electrical Outlets Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Outlet located over an 10" to 25" obstruction max. 34" high located above 44" 43" high and 28" deep over counter 37" high Rec. Solution: Relocate control or mechanism to max. 44" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

240 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 25T Reference Dwg: 3 of 5 Location: Floor 1 Lab Wet 101 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26A Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

241 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26B Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 11 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26C Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

242 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26D Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, View panel at 54 1/4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26E Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted.bottom panel less than 10" high Rec. Solution: Provide smooth kick plate min.. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ After 8 1/2" ADA Assessment and Survey

243 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26F Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Doors or Gates Recessed Door 2010 ADAS Figure Performance Standard: No Quantity: JOB As built : 0 Barrier Door in alcove deeper than 8" does not have min. 18" strike edge clearance Door recessed 9" deep on exit side Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26G Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 3/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

244 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26H Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Book shelves not accessible. Stored items block bookshelf clear floor space Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $ of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26I Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Cords across ground ADA Assessment and Survey

245 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26J Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 25 1/2" high knee clearance Rec. Solution: Provide min.. 1 accessible table of each type Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26K Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26 1/2" high, 10" deep (to side supports) knee clearance Rec. Solution: Provide min. 1 accessible table of each type Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

246 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 26L Reference Dwg: 3 of 5 Location: Floor 1 Geotech Library 103 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27A Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Stairways Sign Exit Door Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Door leading directly into an exit stairway lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT STAIR DOWN (or UP) at latch side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

247 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27B Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Stairway S0201 Stairways Door Closer Interior Adjustment 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 15 lbf Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27C Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Stairways Door Closer Interior Sweep ADA 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 4 second sweep Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route Barrier Severity: 2 Recommended Cost Est $0.00 Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

248 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27D Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Stairway S0201 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Implementation Priority: 3 Implementation Phase: 49" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27E Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel Threshold consists of multiple level changes Rec. Solution: Provide new door threshold at door that does not lead to an accessible route Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: This threshold could act as a trip hazard for the able bodied ADA Assessment and Survey

249 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27F Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Stairway S0201 Stairways Sign Encl Stairway Level ICC A117.1 Barrier Tactile stairway signage not provided to indicate floor level No floor level ID sign provided Rec. Solution: Provide sign Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27G Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Alarms Fire Pull 2010 ADAS Performance Standard: No Quantity: EACH Barrier Fire pull has no usable hardware As built : 1 Fire pull not fist operable Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $3, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

250 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27H Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Stairway S0201 Alarms Fire Pull 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Fire pulls not between 42" and 48" high 63 1/2" high Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27I Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Fire hose bib protrudes 10 /12" at 71 1/2" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

251 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27J Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Stairway S0201 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 52" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 27K Reference Dwg: 4 of 5 Location: Floor 2 Stairway S0201 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

252 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28A Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible signs Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Driving Simulator Lab and Room 201 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28B Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Fire extinguisher protrudes 4 1/4" at 36" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

253 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28C Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Robotic sign stand protrudes 4 1/4" 9 1/4" at 57" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28D Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Signage Visual Information Provided (Exhibitions) ADA Title II Technical Assistance Manual Denial of participation Performance Standard: No Quantity: JOB As built : 1 Barrier Visual sign providing information for program, service or activity not accessible Accessible information not provided at display case Rec. Solution: Provide information in alternate format to provide access to people with vision impairments Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

254 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28E Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 9 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28F Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

255 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28G Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted Rec. Solution: Provide kick plate at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28H Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box 53 1/2" high Rec. Solution: Relocate to area at min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

256 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28I Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high Group of switches 50 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28J Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 2 Barrier Change in level greater than 1/2" in clear floor space Hole in floor Rec. Solution: Repair floor. Remodel where needed Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

257 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28K Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Corridors Protruding Object 2010 ADAS 307 Performance Standard: No Quantity: EACH As built : 2 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Window counter protrudes 6" at 34 1/4" high and electrical boxes at 6/1/2" 6 1/2" at 52 3/4" 68 3/4" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28L Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50" 50 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches ADA Assessment and Survey

258 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28M Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0202 Signage Tactile Exit Signs Passage Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Exit thru an exit enclosure/exit passageway lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT ROUTE at exit side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 28N Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0202 Alarms Horn No Strobe 2010 ADAS 702 Performance Standard: No Quantity: EACH As built : 3 Barrier Horn provided in location where no strobe is provided No strobe device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

259 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29A Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0201 Clear Floor Space Floor Surface Slope 2010 ADAS 302 and 303 Performance Standard: No Quantity: SF Barrier Floor surface slope exceeds 2.0% As built : % slope and 5/8" high threshold that is deteriorating Rec. Solution: Remodel to provide level clear floor space at controls/mechanisms Barrier Severity: 2 Necessary Cost Est $11, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29B Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0201 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 1/2" 50 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches ADA Assessment and Survey

260 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29C Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0201 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 16 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29D Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0201 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

261 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29E Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0201 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29F Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0201 Doors or Gates Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: LF As built : 4 Barrier Change in level greater than 1/2" leading to door 2 1/2" gap at threshold has greater than 1/2" change in level Rec. Solution: Repair threshold to remove trip hazard Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

262 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29G Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Hallway H0201 Doors or Gates Landing Existing ( 5.0%) 2010 ADAS Performance Standard: Barrier No Quantity: SF As built : 30 Door or gate lacks landing on both sides of door 12.5% slope on exterior side Rec. Solution: Demolish and reconstruct level landing Barrier Severity: 1 Necessary Cost Est $3, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 29H Reference Dwg: 4 of 5 Location: Floor 2 Hallway H0201 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

263 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 30A Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Exterior Ramp to Rogers Hall Ramps Ramp Landing Top Landing 2010 ADAS Performance Standard: No Quantity: LF Barrier Top landing is not min. 60" long As built : 12 10" 13" landing length Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 2 Recommended Cost Est $2, Top and bottom landings Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 30B Reference Dwg: 4 of 5 Location: Floor 2 Exterior Ramp to Rogers Hall Ramps Running Slope Existing (>9.5% or more) 2010 ADAS Performance Standard: No Quantity: LF As built : 40 Barrier Running slope exceeds 8.33% (>9.5% or more) 9.8% running slope and 6.4% cross slope Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 1 Necessary Cost Est $8, ADA Assessment and Survey

264 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 30C Reference Dwg: 4 of 5 Location: X Coordinate: Floor 2 Exterior Ramp to Rogers Hall Ramps Handrail Height 2010 ADAS Performance Standard: No Quantity: LF Barrier Handrails not 34" 38" high As built : 22 30" 32" handrail grip height Rec. Solution: Replace handrails at both sides of ramp Barrier Severity: 3 Hindrance Cost Est $4, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31A Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

265 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31B Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31C Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high ADA Assessment and Survey

266 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31D Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted. 9 1/2" high bottom panel Rec. Solution: Provide smooth kick plate min. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31E Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel 3/8" high Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Threshold also uneven ADA Assessment and Survey

267 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31F Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 55 1/2" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31G Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Clear Floor Space Carpet/Rug 2010 ADAS Barrier Carpet/rug not anchored to floor (possible trip hazard) Carpet/rug creates tripping hazard Rec. Solution: Secure exiting carpet/rug or replace Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

268 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31H Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements 20" 30" wide passageway around table Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31I Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26 3/4" knee clearance Rec. Solution: Provide min. 1 accessible group table Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

269 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31J Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Clear floor space for wheelchair not provided at control or mechanism Table, chairs block whiteboard clear floor space Rec. Solution: Rearrange furniture to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31K Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Use of control involves low reach of less than 15" above floor or more than 48" high A/C controls 63 1/4" high Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

270 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31L Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high A/C unit protrudes 8 1/2" at 58 3/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31M Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Counters and Tables Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided Computer workstation 25" high and 24 1/2" wide knee clearance Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

271 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31N Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Desk adjacent to computer workstation 26" high knee clearance Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31O Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Controls and Mechanisms Electrical Outlets Side Reach Obstructed (10" 24") 2010 ADAS Barrier Outlet located over an 10" to 24" obstruction max. 34" high located above 46" Outlets over computer workstation 35 1/4" high and 31 1/4" deep over workstation 30" high Rec. Solution: Relocate control or mechanism to max. 46" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

272 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 31P Reference Dwg: 4 of 5 Location: Floor 2 Driving Simulator Office 206 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32A Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

273 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32B Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32C Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high ADA Assessment and Survey

274 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32D Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted. 7 1/2" high panel Rec. Solution: Provide smooth kick plate min. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32E Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Threshold Height exceeding 1/2" 2010 ADAS Barrier Door/Gate threshold exceeds 1/2" in height 2" high Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

275 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32F Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 6 1/4" strike edge clearance to wall Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32G Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 5 1/4" strike edge clearance to desk. 37 1/2" perpendicular to trash Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

276 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32H Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Doors or Gates Front App/pull 60" Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 37 1/2" perpendicular to door Rec. Solution: Rearrange furniture to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32I Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

277 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32J Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Controls and Mechanisms Coat Hook Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Clothing hooks not max. 48" high AFF As built : 1 64" high Rec. Solution: Provide additional hook Barrier Severity: 2 Recommended Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32K Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Microwave 55" high. Mini fridge blocks microwave clear floor space Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

278 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32L Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32M Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 44" turning space Rec. Solution: Rearrange furniture to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

279 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32N Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24 1/2" 27 3/4" high, 20 1/2" 28 1/4" wide knee clearance Rec. Solution: Provide at least 1 accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ desks. None have accessible knee clearance Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32O Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Controls and Mechanisms Electrical Outlets Hi/Low Reach 2010 ADAS Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 9" high Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

280 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 32P Reference Dwg: 4 of 5 Location: Floor 2 Grad Student Office 207 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33A Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible signs Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

281 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33B Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Signage ISA Directional Sign 2010 ADAS Advisory Performance Standard: Yes Quantity: EACH As built : 1 Barrier No directional signage provided where accessible route diverges from main route Two doors provided. Currently, neither is accessible Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33C Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Door Hardware Operation 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Operating controls involve tight grasping, pinching or twisting Door knobs not fist operable Rec. Solution: Replace hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

282 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33D Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Doors Vision Lights 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, East door. View panel at 54 1/4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33E Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted. 8 1/2" high panel Rec. Solution: Provide smooth kick plate min. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

283 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33F Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Door Threshold (Replace) 2010 ADAS Barrier Door/Gate threshold height exceeds 1/2" 3/4" high Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: East door Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33G Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Doors or Gates Recessed Door 2010 ADAS Figure Performance Standard: No Quantity: JOB As built : 0 Barrier Door in alcove deeper than 8" does not have min. 18" strike edge clearance Door recessed 8" deep Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $0.00 East door ADA Assessment and Survey

284 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33H Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Door Clearance Min. 12" at Push Side 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door lacks min. 12" strike edge clearance at push side 5" strike edge clearance Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $0.00 Push side to wall. East door Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33I Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Door Clearance Min. 18" at Pull Side 2010 ADAS Figure Barrier Door lacks min. 18" strike edge clearance at pull side 17" strike edge clearance Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $5, Pull side to wall. West door ADA Assessment and Survey

285 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33J Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Key box 49" high and not fist operable Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33K Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/4" 50 1/2" high. Stored item blocks light switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches ADA Assessment and Survey

286 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33L Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Door Landing Level 2010 ADAS Performance Standard: No Quantity: SF As built : 20 Barrier Door landing is not level on both sides of door 6.8% slope at door threshold Rec. Solution: Demolish and reconstruct level landing Barrier Severity: 1 Necessary Cost Est $2, West door Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33M Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer Trash bin blocks strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 West door ADA Assessment and Survey

287 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33N Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 7" strike edge clearance Rec. Solution: Move podium Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33O Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Fume Hood Work Surface Rim 2010 ADAS 902 Performance Standard: No Quantity: EACH Barrier Work surface height exceeds 34" high As built : /2" work surface height Rec. Solution: Provide min. 1 accessible fume hood or 5% overall Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

288 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33P Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Fume Hood Reach Range High 2010 ADAS Barrier Control or mechanism not at max. 48" high for side reach Fume hood controls 65 3/4" high Rec. Solution: Provide extension for control to provide reach range Barrier Severity: 3 Hindrance Cost Est $ of 2 fume hoods Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33Q Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Fume Hood Knee Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance not min. 27" high, 19" deep or 30" wide No knee clearance Rec. Solution: Reposition hood to provide knee clearance Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

289 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33R Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Eye Wash Knee Clearance 2010 ADAS & 306 Barrier Knee clearance of at least 27" high, 30" wide and 11" deep not provided 8 1/2" deep knee clearance. Stored items block eyewash clear floor space Rec. Solution: Remount eye wash Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33S Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Counter Surface 2010 ADAS 902 Barrier Counter or workstation surface height exceeds 34" high 38 3/4" high Rec. Solution: Provide min. 1 section of accessible counter at each type of work area Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

290 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33T Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" 39" 51" high and 27" deep over an obstruction 38 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ For valves (4 on the side wall with no windows), scale, lab equipment, outlets Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33U Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Items on shelf behind counter 54" 56" high and 29" 33" deep over an obstruction 38 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

291 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33V Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /4" high Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33W Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : 1 11" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

292 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33X Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33Y Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Counters and Tables Counter Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26" high knee clearance at opening Rec. Solution: Provide min. 1 section of accessible counter at each type of work area Barrier Severity: 3 Hindrance Cost Est $ Middle counter ADA Assessment and Survey

293 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33Z Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Sink Depth Performance Standard Performance Standard: Yes Quantity: LF Barrier Sink depth exceeds 6 1/2" deep As built : 3 11" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $1, sinks Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AA Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible sink at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 Middle counter ADA Assessment and Survey

294 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AB Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator or Control Operation 2010 ADAS Barrier Control or mechanism not usable with a closed fist Compressed gas valve not fist operable Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ Middle counter Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AC Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" AC units and outlets 47 1/2" 66 1/2" high and 27" 35" deep over an obstruction 38 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

295 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AD Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Paper towel/soap dispenser 61 1/2" high and 33" deep over an obstruction 38 1/2" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AE Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation 26 1/4" high knee clearance Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ soldering workstations. None are accessible ADA Assessment and Survey

296 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AF Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Classrooms Desk Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk 26 1/4" high knee clearance at desks in classroom setting Rec. Solution: Provide min. 1 accessible desk or 5% overall Barrier Severity: 1 Necessary Cost Est $ desks. None are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AG Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Classrooms Projector Screen Pull 2010 ADAS Barrier Screen pull not at max. 48" high for side reach Projector screen pull 67" high Rec. Solution: Relocate to max. 48" high or provide extension Barrier Severity: 3 Hindrance Cost Est $75.00 ADA Assessment and Survey

297 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AH Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Projector controls 53" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AI Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Classrooms Podium Surface Height 2010 ADAS Performance Standard: No Quantity: SF Barrier Surface height exceeds 34" high As built : /4" surface height. Chair blocks instructor podium clear floor space Rec. Solution: Provide min. 1 accessible podium and rearrange furniture to provide wheelchair access Barrier Severity: 4 Low Severity Cost Est $1, Instructor podium has 20" clear floor space to chair ADA Assessment and Survey

298 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AJ Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Controls and Mechanisms Electrical Outlets Hi/Low Reach 2010 ADAS & Performance Standard: No Quantity: LF As built : 1 Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 8 1/2" high Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high Barrier Severity: 2 Recommended Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 33AK Reference Dwg: 4 of 5 Location: Floor 2 Graf Laboratory 208 Laboratory Facilities Alarm Horn/Strobe 2010 ADAS Barrier Where a fire alarm is installed, no horn/strobe provided No device provided Rec. Solution: Provide horn/strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

299 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34A Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: 2 entry doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34B Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Door Hardware Operation 2010 ADAS Barrier Operating controls involve tight grasping, pinching or twisting Hardware not fist operable Rec. Solution: Replace hardware Barrier Severity: 1 Necessary Cost Est $ Double doors ADA Assessment and Survey

300 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34C Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 11 lbf Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $5, Double doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34D Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Door Closer Sweep 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 2 second sweep Rec. Solution: Provide automatic door opening device at west door and ISA directional sign at other Barrier Severity: 1 Necessary Cost Est $0.00 Double doors ADA Assessment and Survey

301 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34E Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Double doors. View panel located at 48 1/2" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34F Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Key box 51" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

302 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34G Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 3/4" 59 1/4" high. Recycling bins block light switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Two switches next to both doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34H Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Table blocks whiteboard clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

303 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34I Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Projector Screen Pull 2010 ADAS Barrier Screen pull not at max. 48" high for side reach Projector screen pull 63 1/2 high Rec. Solution: Relocate to max. 48" high or provide extension Barrier Severity: 3 Hindrance Cost Est $75.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34J Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Clear floor space for wheelchair not provided at control or mechanism Podium blocks projector controls and passage to front of room Rec. Solution: Move podium to provide accessible passage to controls Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

304 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34K Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 2 Barrier Circulation route not min. 36" wide between elements Passageway less than 36" in multiple locations Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Instructor podium has 18" wide circulation route. 23" wide circulation route between desks Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34L Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Podium Surface Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Surface height exceeds 34" high As built : /4" surface height. Stored items block instructor podium clear floor space Rec. Solution: Provide min. 1 accessible podium Barrier Severity: 4 Low Severity Cost Est $1, ADA Assessment and Survey

305 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34M Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Podium Knee Clearance 2010 ADAS Performance Standard: No Quantity: SF As built : 0 Barrier Podium knee clearance not min. 27" high, 19" deep or 30" wide No knee clearance Rec. Solution: Provide min. 1 accessible podium Barrier Severity: 4 Low Severity Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34N Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Visual presenter and keyboard 37" 57 1/4" high and 2 1/4" 17" deep over an obstruction 36" 39 1/4" high Rec. Solution: Relocate control or mechanism to max. 44" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

306 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34O Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelves and cabinet not accessible Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $ shelves at 63 1/2" 78" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34P Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Desk Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk 24 1/4" high knee clearance at single desk in instruction area Rec. Solution: Provide min. 1 accessible desk or 5% overall Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

307 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34Q Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism not at min. 15" or max. 48" high AC unit 61 1/2" high Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34R Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Protruding Object Wall mounted 2010 ADAS Barrier Wall mounted object protrudes more than 4" from wall AC unit protrudes 7 3/4" at 52" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

308 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34S Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Printer controls 52" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34T Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Protruding Object Wall mounted 2010 ADAS Barrier Wall mounted object protrudes more than 4" from wall Electrical box protrudes 4 1/4" at 54" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

309 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34U Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Desk Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 2 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk 26 1/2" high and 5" deep knee clearance to legs. Other desk blocks desk clear floor space Rec. Solution: Provide min. 1 accessible desks (seats at desk) or 5% overall Barrier Severity: 1 Necessary Cost Est $1, desks with 38 seats. None are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34V Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS Performance Standard: No Quantity: SF As built : 2 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 56 1/2" 57 1/2" turning space at left and right side computer workstations Rec. Solution: Rearrange furniture to provide wheelchair access Barrier Severity: 2 Recommended Cost Est $ ADA Assessment and Survey

310 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34W Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided 24 1/2" 25 3/4" high knee clearance at 14 PC workstations Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34X Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Electrical Outlets Forward Reach Obstructed (10" 25") 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Outlet located over an 10" to 25" obstruction max. 34" high located above 44" 51 3/4" high and 31" deep over an obstruction 28 1/4" high Rec. Solution: Relocate control or mechanism to max. 44" high Barrier Severity: 2 Recommended Cost Est $ Two computer workstations ADA Assessment and Survey

311 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34Y Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Counter Surface 2010 ADAS 902 Barrier Counter surface height exceeds 34" high 35 3/4" 36 1/4" high Rec. Solution: Provide min. 1 section of accessible counter Barrier Severity: 3 Hindrance Cost Est $ counters provided. None are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34Z Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Actuator/Control Side Reach Obstructed (10" 24") 2010 ADAS Barrier Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46" Faucet and glassware dryer 42 1/4" high 22" deep over 36 1/4" high counter Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

312 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34AA Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /4" high Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34AB Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Sink Knee Clearance 2010 ADAS & 306 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 19" deep and 30" wide not provided No knee clearance Rec. Solution: Provide min. 3 ft of accessible counter at each type of workstation in lab Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

313 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34AC Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Clear floor space for wheelchair not provided at control or mechanism Trash blocks shelves clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 34AD Reference Dwg: 4 of 5 Location: Floor 2 Classroom 210 Classrooms Alarm No Horn/Strobe 2010 ADAS Barrier Where a fire alarm is installed, no horn/strobe provided No device provided Rec. Solution: Provide horn/strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

314 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35A Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible signs Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: 2 entry doors Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35B Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 9 lbf Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door Barrier Severity: 1 Necessary Cost Est $5, entry doors ADA Assessment and Survey

315 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35C Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Doors or Gates Door Closer Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 3 second sweep Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door Barrier Severity: 2 Recommended Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35D Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Doors or Gates Vision Lights Existing 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panels located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $4, /2" high ADA Assessment and Survey

316 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35E Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35F Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall TV protrudes 5 1/2" at 79" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

317 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35G Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Actuator/Control Forward Reach High Unobstructed 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Control or mechanism not at min. 15" or max. 48" high A/C unit controls 63" 63 3/4" high. Desk blocks whiteboard clear floor space Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $ of 2 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35H Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall A/C units protrude 14" at 55" high Rec. Solution: Provide detectable warning for the visually impaired if desk is moved Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

318 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35I Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation 24" 25" high and 24 1/2" 24 3/4" wide knee clearance Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ computer workstations. None are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35J Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Actuator/Control Forward Reach Obstructed ( 10") 2010 ADAS Barrier Control or mechanism over an obstruction max. 34" high located above 48" Printer controls 50 1/2" high and 8 1/2" deep over counter 27 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

319 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35K Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Stereo controls 48 1/4" high and Phone controls 61" high Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35L Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Protruding Object 2010 ADAS Barrier Wall mounted object (dispensers) protrudes more than 4" from wall Phone protrudes 6" at 58 1/2" high Rec. Solution: Relocate, remove object (dispenser) or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

320 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35M Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 39" high from floor. Stored items block chalkboard clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35N Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Counter Surface 2010 ADAS 902 Barrier Counter or workstation surface height exceeds 34" high 36 1/4" high Rec. Solution: Provide min. 1 accessible counter Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

321 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35O Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Counters and Tables Counter Knee Clearance 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26" wide knee clearance at gaps Rec. Solution: Replace counter. Flip up counters, adjacent tables and similar devices not permitted Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35P Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Controls and Mechanisms Electrical Outlets Side Reach Obstructed (10" 24") 2010 ADAS Barrier Outlet located over an 10" to 24" obstruction max. 34" high located above 46" 46 1/4" high and 27 1/2" deep over an obstruction 36 1/4" high Rec. Solution: Relocate control or mechanism to max. 46" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

322 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35Q Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Laboratory Facilities Shelves or Cabinet 2010 ADAS Barrier Shelf or cabinet not mounted between 40" and 48" above floor or ground 55 1/4" 81 1/2" high Rec. Solution: Provide additional shelf/cabinet at accessible height or provide assistance Barrier Severity: 2 Recommended Cost Est $0.00 Shelves over counter Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35R Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover or remove if possible Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Cords on floor. 1/4" lip in clear floor space ADA Assessment and Survey

323 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 35S Reference Dwg: 4 of 5 Location: Floor 2 Class Lab Computer 203 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36A Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Signage Permanent Room/Space Tactile Characters 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible signs Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: For rooms 205, 205A ADA Assessment and Survey

324 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36B Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Controls and Mechanisms Actuator/Control Fist Operable 2010 ADAS Barrier Control or mechanism not usable with a closed fist Key box not fist operable Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36C Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 11 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

325 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36D Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Doors or Gates Door Closer Interior Closing Speed ADA 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period/back check 3 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36E Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

326 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36F Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36G Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 53 1/2" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

327 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36H Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Clear Floor Space Carpet/Rug 2010 ADAS Barrier Carpet/rug not anchored to floor (possible trip hazard) Carpet/rug creates tripping hazard Rec. Solution: Secure exiting carpet/rug or replace Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36I Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements 28" wide circulation route between chairs Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

328 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 36J Reference Dwg: 4 of 5 Location: Floor 2 Workroom 205 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37A Reference Dwg: 4 of 5 Location: Floor 3 Stairway S0301 Stairways Sign Enclosed Exit Stairway Door Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Door leading directly into an exit stairway lacks tactile exit sign Door to exit stair with low level illuminated sign lacks tactile exit sign Rec. Solution: Provide sign stating EXIT STAIR DOWN (or UP) at latch side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

329 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37B Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Stairway S0301 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37C Reference Dwg: 5 of 5 Location: Floor 3 Stairway S0301 Stairways Door Closer Interior Adjustment 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 12 lbf Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

330 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37D Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Stairway S0301 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Implementation Priority: 3 Implementation Phase: 48 1/4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37E Reference Dwg: 5 of 5 Location: Floor 3 Stairway S0301 Doors or Gates Threshold Height exceeding 1/2" 2010 ADAS Barrier Door/Gate threshold exceeds 1/2" in height Threshold is deteriorating Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

331 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37F Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Stairway S0301 Stairways Sign Encl Stairway Level ICC A117.1 Barrier Tactile stairway signage not provided to indicate floor level No floor level ID sign provided Rec. Solution: Provide sign Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37G Reference Dwg: 5 of 5 Location: Floor 3 Stairway S0301 Alarms Fire Pull 2010 ADAS Performance Standard: No Quantity: EACH Barrier Fire pull has no usable hardware As built : 1 Fire pull not fist operable Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $3, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

332 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37H Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Stairway S0301 Alarms Fire Pull 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Fire pulls not between 42" and 48" high 61" high Rec. Solution: Replace fire pull when remodeling Barrier Severity: 4 Low Severity Cost Est $0.00 Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 37I Reference Dwg: 5 of 5 Location: Floor 3 Stairway S0301 Stairways Protruding Hazard 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Object protrudes more than 4" into pedestrian way Valve protrudes 10 1/2" at 67 1/2" Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

333 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38A Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Corridors Sign Permanent Room/Space 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier No sign with raised characters and Braille at permanent room or space with visual sign Provide accessible signs Rec. Solution: Provide sign at latch side of entry door, where possible Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Rooms 308 and 309 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38B Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Corridors Door Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Replace hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

334 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38C Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 11 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38D Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Corridors Door Closer Interior Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 4 second sweep Rec. Solution: Provide automatic door opening device Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

335 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38E Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38F Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 3/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

336 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38G Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Signage Tactile Exit Signs Passage Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Exit thru an exit enclosure/exit passageway lacks tactile exit sign Passageway to exterior exit with low level illuminated sign lacks tactile exit sign Rec. Solution: Provide sign stating EXIT ROUTE at exit side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38H Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Corridors Protruding Object 2010 ADAS 307 Performance Standard: No Quantity: EACH As built : 2 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Fire extinguisher protrudes 5 1/2" at 31 1/4" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $1, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

337 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38I Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Controls and Mechanisms Electrical Outlets Hi/Low Reach ADAAG 4.9.4* & 2010 ADAS Performance Standard: No Quantity: LF As built : 1 Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 12" high Rec. Solution: Relocate outlet to min. 15" or max. 48" high Barrier Severity: 2 Recommended Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38J Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Signage Visual Information Provided (Exhibitions) ADA Title II Technical Assistance Manual Denial of participation Performance Standard: No Quantity: JOB As built : 1 Barrier Visual sign providing information for program, service or activity not accessible Accessible sign not provided Rec. Solution: Provide information in alternate format to provide access to people with vision impairments Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

338 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38K Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Desk is not accessible for people that use wheelchairs Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38L Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Corridors Protruding Object 2010 ADAS 307 Barrier Protruding object in in circulation path protrudes more than 4" between 27" and 80" high Electrical box protrudes 4 1/2" at 43" high Rec. Solution: Remove object or provide detectable warning (wing walls) Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

339 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38M Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Controls and Mechanisms Electrical Switches Height 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Light switch control box top edge not at max. 48" high 50 1/4" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38N Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0300 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 10 Barrier Change in level greater than 1/2" in clear floor space 1" lip in clear floor space Rec. Solution: Repair trip hazard. Remodel where needed Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

340 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 38O Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0300 Alarms Horn/Strobe Corridor 2010 ADAS Performance Standard: No Quantity: EACH Barrier No horn/strobes in corridor As built : 1 No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39A Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0301 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel Threshold is deteriorating Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

341 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39B Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0301 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/4" 50 1/2" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ switches Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39C Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0301 Controls and Mechanisms Electrical Outlets Hi/Low Reach ADAAG 4.9.4* & 2010 ADAS Performance Standard: No Quantity: LF As built : 1 Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 12" high Rec. Solution: Relocate outlet to min. 15" or max. 48" high Barrier Severity: 2 Recommended Cost Est $ ADA Assessment and Survey

342 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39D Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0301 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 11 lbf Rec. Solution: Provide automatic door opening device for door leading to connecting ramp Barrier Severity: 1 Necessary Cost Est $5, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39E Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0301 Corridors Door Closer Interior Sweep Period 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Door closer lacks min. 5 second sweep period 3 second sweep Rec. Solution: Provide automatic door opening device for door leading to connecting ramp Barrier Severity: 2 Recommended Cost Est $0.00 ADA Assessment and Survey

343 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39F Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0301 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39G Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0301 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel 1/2" high Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

344 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39H Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0301 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 8 3/4" strike edge clearance Rec. Solution: Provide automatic door opening device for door leading to connecting ramp Barrier Severity: 1 Necessary Cost Est $0.00 Push side to wall Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39I Reference Dwg: 5 of 5 Location: Floor 3 Hallway H0301 Doors or Gates Front App/pull 60" Relocate Door 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 58" perpendicular to door Rec. Solution: Provide automatic door opening device for door leading to connecting ramp Barrier Severity: 1 Necessary Cost Est $0.00 At pull side of door to the wall ADA Assessment and Survey

345 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 39J Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Hallway H0301 Alarms Horn/Strobe Corridor 2010 ADAS Performance Standard: No Quantity: EACH Barrier No horn/strobes in corridor As built : 1 No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 40A Reference Dwg: 5 of 5 Location: Floor 3 Exterior Ramp to Rogers Hall Ramps Ramp Landing Top Landing 2010 ADAS Performance Standard: No Quantity: LF Barrier Top landing is not min. 60" long As built : 12 6" landing length Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 2 Recommended Cost Est $2, Top and bottom landings ADA Assessment and Survey

346 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 40B Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Exterior Ramp to Rogers Hall Ramps Cross Slope Existing (>5.0% or more) 2010 ADAS Performance Standard: No Quantity: LF As built : 40 Barrier Cross slope exceeds 2.0% (>5.0% or more) 5.3% cross slope Rec. Solution: Demolish existing and construct new ramp Barrier Severity: 1 Necessary Cost Est $8, % running slope Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 40C Reference Dwg: 5 of 5 Location: Floor 3 Exterior Ramp to Rogers Hall Ramps Handrail Height 2010 ADAS Performance Standard: No Quantity: LF Barrier Handrails not 34" 38" high As built : 22 32" 38" handrail grip height Rec. Solution: Replace handrails at both sides of ramp Barrier Severity: 3 Hindrance Cost Est $4, The handrails are not parallel with the ramp surface ADA Assessment and Survey

347 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41A Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41B Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

348 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41C Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, " high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41D Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Doors or Gates Threshold Height exceeding 1/4" without bevel 2010 ADAS Barrier Door/Gate threshold exceeds 1/4" in height without a bevel 1/4" high and breaking apart Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

349 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41E Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 8" strike edge clearance to desk Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41F Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 57 1/2" high. Desk blocks electrical switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

350 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41G Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block whiteboard clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41H Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelving above 48" high Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

351 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41I Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Coat Hook Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Clothing hooks not max. 48" high AFF As built : 1 67" high. Chair and desk block coat hook clear floor space Rec. Solution: Provide additional hook Barrier Severity: 2 Recommended Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41J Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Cords on floor ADA Assessment and Survey

352 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41K Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Use of control involves low reach of less than 15" above floor or more than 48" high A/C unit controls 54" high. Table blocks A/C unit clear floor space Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41L Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high A/C unit protrudes 14" at 45" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

353 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41M Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 53" turning space between chairs Rec. Solution: Rearrange furniture/equipment to provide wheelchair access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41N Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24" 26 3/4" high, 18" 18 1/2" deep and 24 1/2" 25 1/4" wide knee clearance Rec. Solution: Provide min. 1 accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ desks. None are accessible ADA Assessment and Survey

354 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41O Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf over desk 53 1/4" high and 21 3/4" deep over 29 3/4" desk Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41P Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Desks block outlet clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

355 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 41Q Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 305 Controls and Mechanisms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42A Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

356 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42B Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Door Hardware Operation 2010 ADAS Barrier Operating controls involve tight grasping, pinching or twisting Hardware not fist operable Rec. Solution: Replace hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42C Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high ADA Assessment and Survey

357 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42D Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted. 9 3/4" high bottom panel Rec. Solution: Provide smooth kick plate min. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42E Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Actuator or Control Operation 2010 ADAS Barrier Control or mechanism not usable with a closed fist Key box not fist operable Rec. Solution: Replace operating control Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

358 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42F Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 49" high. Trash blocks light switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42G Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Controls and Mechanisms First Aid Kit High Reach Range 2010 ADAS Barrier ing mechanism on first aid kit not at max. 48" high for side reach 60 1/2" high and First aid kit not fist operable Rec. Solution: Relocate control or mechanism to max. 48" high Barrier Severity: 1 Necessary Cost Est $ desks with 2 accessible desks/tables ADA Assessment and Survey

359 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42H Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements 32 3/4" wide passage to ADA desk Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42I Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 34" turning space at ADA desk Rec. Solution: Move stored items blocking maneuvering clearance Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

360 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42J Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Desk Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk Instructors desk has 17" knee clearance Rec. Solution: Provide min. 1 accessible desk or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42K Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block telephone clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ Under instructors desk ADA Assessment and Survey

361 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42L Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Counter Surface 2010 ADAS 902 Barrier Counter surface height exceeds 34" high 36 3/4" high surface Rec. Solution: Replace or provide alternative accessible and integrated counter Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42M Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Actuator/Control Side Reach Obstructed (10" 24") 2010 ADAS Barrier Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46" Gas valve 40 1/4" high and 26" deep over an obstruction 36 3/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

362 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42N Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Actuator/Control Side Reach Obstructed (10" 24") 2010 ADAS Barrier Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46" Faucet controls are 39 3/4" high, 25 1/4" deep over 36 3/4" counter Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42O Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Sink Rim or Countertop 2010 ADAS Performance Standard: No Quantity: LF Barrier Sink rim or surface not max. 34" high As built : /4" high. Wall block sink clear floor space Rec. Solution: Provide min. 1 accessible sink or at least one of each type Barrier Severity: 1 Necessary Cost Est $1, " perpendicular to wall from sink ADA Assessment and Survey

363 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42P Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Sink Depth Performance Standard Performance Standard: Yes Quantity: EACH Barrier Sink depth exceeds 6 1/2" deep As built : 1 10" deep Rec. Solution: Provide min. 1 accessible sink Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42Q Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Emergency phone 50 1/2" high Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

364 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42R Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Protruding Object Wall mounted 2010 ADAS Barrier Wall mounted object protrudes more than 4" from wall Emergency phone protrudes 5" at 50 1/2" high in path of travel into room Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42S Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 39 3/4" high from floor Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, ADA Assessment and Survey

365 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 42T Reference Dwg: 5 of 5 Location: Floor 3 Classroom 306 Classrooms Alarm No Horn/Strobe 2010 ADAS Barrier Where a fire alarm is installed, no horn/strobe provided No device provided Rec. Solution: Provide horn/strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43A Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

366 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43B Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43C Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Doors or Gates Threshold Height exceeding 1/2" 2010 ADAS Barrier Door/Gate threshold exceeds 1/2" in height 5/8" high Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

367 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43D Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/2" high Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43E Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Controls and Mechanisms Coat Hook Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Clothing hooks not max. 48" high AFF As built : /4" high Rec. Solution: Provide additional hook Barrier Severity: 2 Recommended Cost Est $ ADA Assessment and Survey

368 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43F Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 44 1/2" high and 30 3/4" deep over a desk 29" high Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43G Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Controls and Mechanisms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Microwave 60" high and 14 1/2" deep over a cabinet 52 1/4" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

369 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43H Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements 22" wide passage to back desks between desk and wall Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43I Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Clear Floor Space Clear Floor Space 60" Turning Circle 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 60" in diameter not provided where 360 degree turn is made 27" turning space at back of room Rec. Solution: Move stored items blocking maneuvering clearance Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

370 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43J Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 24 1/2" 25 1/2" high, 27 1/2" wide and 18" 18 1/2" depth knee clearance Rec. Solution: Provide accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ desks and none are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43K Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 307A Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Shelves over desk 40 1/4" to 53" high and 22" deep over an obstruction 29 1/2" high. 5 shelves ADA Assessment and Survey

371 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 43L Reference Dwg: 5 of 5 Location: X Coordinate: Floor 3 Grad Student Office 307A Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44A Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Permanent Room/Space Sign Tactile Characters 2010 ADAS Performance Standard: Barrier No Quantity: EACH As built : 1 At interior or exterior location, no tactile characters at sign identifying permanent rooms and spaces No tactile signage provided at door within public route Rec. Solution: Provide accessible sign Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

372 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44B Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Door Hardware Operation 2010 ADAS Barrier Operating controls involve tight grasping, pinching or twisting Hardware not fist operable Rec. Solution: Replace hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44C Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Doors Vision Lights 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, Double doors. 54 1/4" high ADA Assessment and Survey

373 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44D Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Door Threshold (Replace) 2010 ADAS Performance Standard: No Quantity: EACH As built : 2 Barrier Door/Gate threshold height exceeds 1/2" Threshold is deteriorating and has multiple levels Rec. Solution: Provide new door threshold Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44E Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/2" high. Stored elements block light and fan switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

374 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44F Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 44 1/2" high from floor. Desks block chalkboard clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44G Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 6 Barrier Circulation route not min. 36" wide between elements 20" wide to desk marked as accessible. 20" wide to professor's desk. 6" passage wide to emergency phone Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

375 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44H Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Desk Ratio 2010 ADAS 902 Barrier At least 1 desk or 5% of all desks not accessible At least 2 accessible desks not provided Rec. Solution: Provide at least 2 accessible desks Barrier Severity: 3 Hindrance Cost Est $ desks and none are accessible Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44I Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Desk Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 0 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk Desk marked as accessible has 26" knee clearance, but is adjustable by hand crank Rec. Solution: Provide min. 1 accessible desk or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 Desk is adjustable and can be accessible if raised to the correct height ADA Assessment and Survey

376 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44J Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Desk Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath desk Instructor's desk has 26 1/2" high knee clearance Rec. Solution: Provide min. 1 accessible instructors desk where student may give presentations Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44K Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Desk Integration 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Desk not integrated into assembly seating Desk identified as accessible is not integrated into typical seating Rec. Solution: Move desk to integrated setting Barrier Severity: 2 Necessary Cost Est $0.00 At front of room ADA Assessment and Survey

377 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44L Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Actuator/Control Forward Reach High Unobstructed 2010 ADAS Barrier Control or mechanism not at min. 15" or max. 48" high Emergency phone 50" high. Chair blocks emergency phone clear floor space Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44M Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 43" high from floor. Desks block whiteboard clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, ADA Assessment and Survey

378 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44N Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Actuator/Control Forward Reach Obstructed (10" 25") 2010 ADAS Barrier Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44" Projector screen switch 51 1/2" high and 22 1/2" deep over an obstruction 32" high Rec. Solution: Relocate control or mechanism to max. 44" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 44O Reference Dwg: 5 of 5 Location: Floor 3 Classroom 307 Classrooms Alarm No Horn/Strobe 2010 ADAS Barrier Where a fire alarm is installed, no horn/strobe provided No device provided Rec. Solution: Provide horn/strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

379 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45A Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Signage Tactile Exit Signs Passage Performance Standard Performance Standard: Yes Quantity: EACH As built : 1 Barrier Exit thru an exit enclosure/exit passageway lacks tactile exit sign Provide accessible sign Rec. Solution: Provide sign stating EXIT ROUTE at exit side of door Barrier Severity: 2 Recommended Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45B Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Shelves in cabinet 55 1/2" 65" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ One unit with four doors ADA Assessment and Survey

380 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45C Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Fire extinguisher protrudes 5" at 30 3/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45D Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No maneuvering clearance provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Room 301 sign ADA Assessment and Survey

381 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45E Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Signage Location Within 18" of Door 2010 ADAS Barrier Approach to tactile characters on sign not centered at 18" minimum from door swing Approach to sign to room 301 blocked by fire extinguisher Rec. Solution: Relocate sign or replace Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45F Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Clear Floor Space Wheelchair Use 2010 ADAS 305 Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space of min. 30" by 48" not provided Materials block workstation clear floor space Rec. Solution: Move stored items at control or mechanism Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

382 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45G Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Electrical box protrudes 8" at 54 1/2" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45H Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Counters and Tables Table Pedestal Base 2010 ADAS and Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Pedestal base blocks knee clearance at both tables in room Rec. Solution: Ensure that rooms where these tables are sent also have accessible tables Barrier Severity: 2 Recommended Cost Est $ ADA Assessment and Survey

383 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45I Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45J Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Controls and Mechanisms Clear Floor Space Stored Elements 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Clear floor space for wheelchair not provided at control or mechanism Stored items block shelves clear floor space Rec. Solution: Move stored items Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

384 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45K Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Stairways Handrail ing Limitations Performance Standard Performance Standard: Yes Quantity: LF As built : 300 Barrier Guard or handrail have openings that allow passage of a 4" sphere Guardrail has openings of more than 4" and is not min. 42" high Rec. Solution: Replace guardrail Barrier Severity: 1 Necessary Cost Est $67, Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45L Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 42 1/4" high from floor. Stored items block whiteboard clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, ADA Assessment and Survey

385 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45M Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Classrooms Workstation Knee Clearance 2010 ADAS 902 Performance Standard: No Quantity: EACH As built : 3 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided 26 1/4" 26 3/4" high knee clearance. Stored items block workstations clear floor space Rec. Solution: Ensure that 5% of desks are accessible when supplying rooms in building Barrier Severity: 1 Necessary Cost Est $2, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45N Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 10 Barrier Change in level greater than 1/2" in clear floor space 1/4" lip in clear floor space due to debris on floor Rec. Solution: Repair trip hazard. Remodel where needed Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

386 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45O Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Circulation route not min. 36" wide between elements 13" wide passageway between cart and chair Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45P Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Pipes protrude 25 1/2" at 55" high if stored items are removed Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

387 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45Q Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Classrooms Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided Workstation has 24 1/4" high knee clearance. Stored items block workstation clear floor space Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45R Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high Faucet protrudes 9 3/4" at 37 3/4" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

388 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 45S Reference Dwg: 5 of 5 Location: Floor 3 Storage 300 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46A Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

389 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46B Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46C Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Doors or Gates Door Closer Interior Automatic Door 2010 ADAS Performance Standard: No Quantity: EACH Barrier Door opening force exceeds 5 lbf As built : 1 10 lbf Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $5, ADA Assessment and Survey

390 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46D Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, /4" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46E Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: EACH As built : 0 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 8 3/4" strike edge clearance at recess due to structural element Rec. Solution: Provide automatic door opening device Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

391 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46F Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Doors or Gates Front App/pull 18" SEC Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side 3 1/2" strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 Pull side to trash Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46G Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50" high. Table/trash block switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

392 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46H Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide 26 1/2" high and 11" deep knee clearance Rec. Solution: Provide min. 1 accessible table Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46I Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation Soldering station 23" high, 5 3/4" deep knee clearance Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

393 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46J Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Counters and Tables Counter Sharp Surfaces 2010 ADAS Performance Standard: No Quantity: JOB As built : 0 Barrier Counter has sharp or abrasive surfaces on edge, apron or underside Sharp surfaces may come into contact with legs of persons with mobility impairments Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $0.00 Soldering station legs have rusted/abrasive surfaces Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46K Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Whiteboards 40 1/2" 41" high. Tables/materials block whiteboards clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, of 2 ADA Assessment and Survey

394 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46L Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation 25" high, 26 1/2" wide, 4" deep knee clearance at computer workstation Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46M Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Laboratory Facilities Toe Clearance Depth 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Toe clearance of at least 17" deep or max. 25" deep not provided Toe clearance for computer workstation is blocked by the lower shelf Rec. Solution: Remove stored items to provide toe clearance Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

395 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46N Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Counters and Tables Table Pedestal Base 2010 ADAS and Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Pedestal base blocks knee clearance Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables. Barrier Severity: 2 Recommended Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46O Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Pedestal based table. Cords on ground obstruct clear floor space ADA Assessment and Survey

396 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46P Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Use of control involves low reach of less than 15" above floor or more than 48" high AC unit controls 52 3/4" high. Wooden device blocks AC unit clear floor space Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46Q Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Classrooms Projector Screen Pull 2010 ADAS Barrier Screen pull not at max. 48" high for side reach Projector screen pull 85 high Rec. Solution: Relocate to max. 48" high or provide extension Barrier Severity: 3 Hindrance Cost Est $75.00 Height measured to handle; no pull provided ADA Assessment and Survey

397 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46R Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation Electrical workstation has 26 3/4" high knee clearance Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46S Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Laboratory Facilities Workstation Knee Clearance 2010 ADAS 902 Barrier Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath workstation Small computer workstation 24 1/2" high, 27" wide knee clearance Rec. Solution: Provide min. 1 accessible workstation of each type Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

398 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 46T Reference Dwg: 5 of 5 Location: Floor 3 Grad Student Office 302 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47A Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: ADA Assessment and Survey

399 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47B Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Doors or Gates Vision Lights Existing 2010 ADAS Barrier View panels in or adjacent to doors or gates not max. 43" above floor or ground View panel located higher than 43" above the floor Rec. Solution: Replace door/gate or vision panel Barrier Severity: 3 Hindrance Cost Est $2, " high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47C Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Doors or Gates Front App/pull 60" Blocked 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at with min. 18" at pull side lacks min. 60" perpendicular to door 2" strike edge clearance Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 pull side to stored items ADA Assessment and Survey

400 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47D Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Barrier Use of control involves low reach of less than 15" above floor or more than 48" high Key box on door 54" high Rec. Solution: Relocate within accessible reach range Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47E Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 1/4" high. Stored items block light switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

401 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47F Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Counters and Tables Table Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Robot arm table 1 1/4" deep knee clearance. Table block robot arm controls clear floor space Rec. Solution: Provide min. 1 accessible table of each type Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47G Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Clear Floor Space Passageway Min. 36" (Stored Item) 2010 ADAS Performance Standard: No Quantity: JOB As built : 2 Barrier Circulation route not min. 36" wide between elements 14" wide circulation route to robot arm and 27" wide circulation route between tables Rec. Solution: Rearrange equipment/furniture to provide access Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

402 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47H Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Counters and Tables Table Pedestal Base 2010 ADAS & Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Pedestal base blocks knee clearance Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables. Barrier Severity: 2 Recommended Cost Est $ desks with 4 fully accessible desks Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47I Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip in clear floor space due to cords on floor Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

403 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47J Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 41" 46 1/2" high from floor Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47K Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Use of control involves low reach of less than 15" above floor or more than 48" high A/C controls 52 1/4" 56 1/2" high and 5" deep over 42" high. Stored items block A/C unit clear floor space Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $ of 2. On shelf and desk ADA Assessment and Survey

404 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47L Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high A/C units protrude 6" 7 1/2" at 43 1/2" high Rec. Solution: Provide detectable warning for the visually impaired if desk is removed Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 47M Reference Dwg: 5 of 5 Location: Floor 3 Robotics & Human Controls Lab 303 Alarms Horn/Strobe Common Use Area 2010 ADAS Barrier No horn/strobes in common use areas No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

405 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48A Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Signage Permanent Room/Space Tactile Characters 2010 ADAS Barrier No tactile characters at sign identifying permanent rooms and spaces with visual signs No accessible sign provided Rec. Solution: Provide accessible sign Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 3 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48B Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Doors or Gates Hardware Operation 2010 ADAS Barrier Hardware not operable with a closed fist Hardware not fist operable Rec. Solution: Provide new hardware Barrier Severity: 1 Necessary Cost Est $ ADA Assessment and Survey

406 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48C Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Doors or Gates Door 10" Bottom Surface Kickplate 2010 ADAS Barrier Door/Gate lacks min. 10" smooth uninterrupted bottom surface Bottom of door not smooth and uninterrupted. 8 3/4" high bottom panel Rec. Solution: Provide smooth kick plate min. 10" high at push side of door Barrier Severity: 1 Necessary Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48D Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Doors or Gates Front App/push 12" SEC 2010 ADAS Figure Performance Standard: No Quantity: ADMINI As built : 1 Barrier Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer 5 1/2" strike edge clearance to stored metal sheets Rec. Solution: Remove stored item Barrier Severity: 1 Necessary Cost Est $0.00 ADA Assessment and Survey

407 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48E Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Controls and Mechanisms Electrical Switches Height 2010 ADAS Barrier Light switch control box top edge not at max. 48" high 50 3/4" high. Metal sheets block switch clear floor space Rec. Solution: Relocate switch box top edge to max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48F Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Controls and Mechanisms Coat Hook Height 2010 ADAS Performance Standard: No Quantity: EACH Barrier Clothing hooks not max. 48" high AFF As built : /2" high Rec. Solution: Provide additional hook Barrier Severity: 2 Recommended Cost Est $ ADA Assessment and Survey

408 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48G Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Classrooms Chalkboard/Whiteboard Area of Use Performance Standard & 2010 ADAS Performance Standard: Yes Quantity: EACH As built : 1 Barrier Bottom edge of writing surface not max. 38" high Lower edge of writing surface 39 1/4" 40 1/4" high from floor. Items, shelves, desk block chalkboards clear floor space Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people Barrier Severity: 3 Hindrance Cost Est $1, of 3 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48H Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Counters and Tables Desk Knee Clearance 2010 ADAS Barrier Knee clearance not min. 27" high, 19" deep or 30" wide Wood desks have 25 1/2" 26 1/2" high knee clearance Rec. Solution: Provide min. 1 accessible desk or workstation Barrier Severity: 3 Hindrance Cost Est $ total desks. None are accessible ADA Assessment and Survey

409 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48I Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Controls and Mechanisms Shelves or Cabinets 2010 ADAS Performance Standard: No Quantity: JOB As built : 1 Barrier Shelf or cabinet not mounted max. 48" above floor or ground Shelf or cabinet not accessible. Stored items block shelving clear floor space Rec. Solution: Provide additional shelf at accessible height or provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 Tool box top shelf 54" high Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48J Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Clear Floor Space Abrupt Change in Level 2010 ADAS Performance Standard: No Quantity: SF As built : 1 Barrier Change in level greater than 1/2" in clear floor space 1/2" lip without a bevel in accessible route due to cords Rec. Solution: Provide cord cover Barrier Severity: 1 Necessary Cost Est $75.00 Implementation Priority: 1 Implementation Phase: Cords in circulation path create a tripping hazard ADA Assessment and Survey

410 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48K Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Controls and Mechanisms Electrical Outlets Hi/Low Reach 2010 ADAS Barrier Use of outlet involves low reach of less than 15" above floor or more than 48" high 5" high Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48L Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 39 1/2" workstation surface height Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $ ADA Assessment and Survey

411 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48M Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Laboratory Facilities Workstation Surface 2010 ADAS 902 Barrier Table or workstation surface height exceeds 34" high 41" computer workstation surface height Rec. Solution: Provide min. 1 accessible workstation or 5% overall Barrier Severity: 3 Hindrance Cost Est $ Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48N Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Controls and Mechanisms Actuator/Control Hi/low Reach 2010 ADAS Performance Standard: No Quantity: EACH As built : 0 Barrier Use of control involves low reach of less than 15" above floor or more than 48" high AC controls 57 1/2" high Rec. Solution: Provide assistance Barrier Severity: 3 Hindrance Cost Est $0.00 ADA Assessment and Survey

412 Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48O Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Clear Floor Space Protruding Object 2010 ADAS 307 Barrier Protruding object in circulation path protrudes more than 4" between 27" and 80" high AC unit protrudes 8" at 49" high Rec. Solution: Remove object or provide detectable warning for the visually impaired Barrier Severity: 1 Necessary Cost Est $ Implementation Priority: 1 Implementation Phase: Field Date: 4/30/2014 Report Date 9/10/2014 Barrier #: 48P Reference Dwg: 5 of 5 Location: Floor 3 Robotics and Applied Mechanics Lab 304 Alarms Horn/Strobe Classroom 2010 ADAS Performance Standard: No Quantity: EACH Barrier No horn/strobes in classroom As built : 1 No device provided Rec. Solution: Provide strobe in common use area Barrier Severity: 1 Necessary Cost Est $5, Implementation Priority: 1 Implementation Phase: ADA Assessment and Survey

413 COST ESTIMATE SUMMARY

Priority 3 - Toilet Rooms

Priority 3 - Toilet Rooms The ADA Checklist for Readily Achievable Barrier Removal Priority 3 - Toilet Rooms Project Building Location Date Surveyors Contact Information When toilet rooms are open to the public they should be accessible

More information

WALKS AND SIDEWALKS REQUIREMENTS:

WALKS AND SIDEWALKS REQUIREMENTS: DOUBLE PARKING STALLS DIAGONAL PARKING STALLS EXTERIOR ROUTES OF TRAVEL: From accessible parking spaces, provide most practical direct accessible route of travel to all building entrances and exteriorground

More information

Priority 3 - Toilet Rooms

Priority 3 - Toilet Rooms The ADA Checklist for Existing Facilities Priority 3 - Toilet Rooms Based on the 2010 ADA Standards for Accessible Design Project Building Location Date Surveyors Contact Information When toilet rooms

More information

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES City Of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA BUILDING CODE - SECTION 11B-213

More information

WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5

WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5 Page 1 of 5 When toilet rooms are provided, each toilet room shall comply with Section 11B-213.2 of the California Building Code. Unisex toilet rooms (Single-use or family) shall contain not more than

More information

Chapter 4. Accessible Routes

Chapter 4. Accessible Routes ICC/ANSI A117.1-2003 401 General 401.1 Scope. Accessible routes required by the scoping provisions adopted by the administrative authority shall comply with the applicable provisions of Chapter 4. 402

More information

REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map

REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map Electrical Information Breaker Panel 1: Service Type: 120/208 Panel Type: LP2 Panel Number: CHH31500 Manufacturer: Cutler Hammer Amps: 150 Location: Back Room Breaker Panel 2: Service Type: 120/208 Panel

More information

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7} KEYS TO COMPLIANCE : Grab bars are required to be at a height of 33 to 36 inches. A117.1 and 2010 Standards measure to the top of the graspable surface. Graphics in ADAAG and earlier editions of A117.1

More information

NCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice

NCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice NCIDQ Restroom Drawing Answers to the most common questions about this drawing for the Practicum. 2016 Qpractice Table of Contents This is a summary guide of most frequently asked questions about the Practicum

More information

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec.11B-305,604,605 Effective: 01/01/2017 DOCUMENT NO.: P/BC 2017-087 Revised: Previously Issued As: P/BC 2014-087 ACCESSIBILITY DETAILS

More information

404 Doors, Doorways, and Gates

404 Doors, Doorways, and Gates 404 Doors, Doorways, and Gates 404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2. 404.2.2 Double-Leaf Doors and

More information

Environmental component, the complete Housing Enabler instrument. Susanne Iwarsson & Björn Slaug Yes

Environmental component, the complete Housing Enabler instrument. Susanne Iwarsson & Björn Slaug Yes Environmental component Environmental component, the complete Housing Enabler instrument. Susanne Iwarsson & Björn Slaug 2010. Personal component / functional profile A. EXTERIOR SURROUNDINGS RATING General

More information

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2 City of Los Angeles Plan Check No. 1. Except building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos, new or altered signs

More information

Accessible Toilet Stalls 6/18/03 1

Accessible Toilet Stalls 6/18/03 1 Accessible Toilet Stalls 6/18/03 1 Section 11-4.17 Toilet Stalls Florida standard stall (11-4.17.3.1) In new construction the standard accessible stall shall contain an accessible lavatory within it, the

More information

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines July 23, 2004 U N I T E D S T A T E S A C C E S S B O A R D A FEDERAL AGENCY COMMITTED TO ACCESSIBLE DESIGN TECHNICAL

More information

ACCESSIBILITY REQUIREMENTS FOR SINKS

ACCESSIBILITY REQUIREMENTS FOR SINKS ACCESSIBILITY REQUIREMENTS FOR SINKS 1. Max. Height to top of counter at sink 2. Min. toe clearance 3. Plan view of 30 x48 clear space and depth 4. Min. knee clearance 5. Plan view of 30 x48 clear space

More information

INTERIOR SIGNAGE MANUAL

INTERIOR SIGNAGE MANUAL INTERIOR SIGNAGE MANUAL ➊ Purpose ➋ Procedures ➌ ADA Requirements INTERIOR SIGNAGE MANUAL ➍ Text, Braille, Pictograms and Color ➎ Families of Interior Signage ➏ Mounting Guidelines ➐ Signage Diagrams ➑

More information

Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers

Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers 4.2.5* Forward Reach. If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48

More information

Solutions AGRICULTURAL LABORATORY & CLASSROOM FURNITURE. Education to Industry. Solutions for Your Workspace & Storage Needs

Solutions AGRICULTURAL LABORATORY & CLASSROOM FURNITURE. Education to Industry. Solutions for Your Workspace & Storage Needs AGRICULTURAL LABORATORY & CLASSROOM FURNITURE Education to Industry for Your Workspace & Storage Needs www.ageducationalsolutions.com 864-256-0621 info@ageducationalsolutions.com Workbenches Potting Benches

More information

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable

More information

Mahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620

Mahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620 W 88th St Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will

More information

BUILDING SIGN PROGRAM JULY 2012

BUILDING SIGN PROGRAM JULY 2012 BUILDING SIGN PROGRAM JULY 2012 TABLE OF CONTENTS Introduction... 2 General Information for all Signs... 3 Sign Selection Considerations... 4 Typography... 5 Color Schedule... 6 Glossary... 7 Interior

More information

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO. INFORMATION INSTRUCTIONS CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO. 2 PROJECT NO.: EXPIRATION DATE: STATUS:

More information

A1.1 FOX GARAGE VAN VAN VAN VAN 11/16/ WASHINGTON BLVD ST. LOUIS, MO REVISIONS FLOOR PLAN - LEVEL /01/14

A1.1 FOX GARAGE VAN VAN VAN VAN 11/16/ WASHINGTON BLVD ST. LOUIS, MO REVISIONS FLOOR PLAN - LEVEL /01/14 BUILDING FLOOR PLAN TES: 1. ALL DIMENSIONS ARE TO FACE OF CONCRETE OR CENTERLINE OF COLUMN (U). 2. SEE ENLARGED STAIR PLANS (A2.1-A2.3) FOR DETAILED INFORMATION T SHOWN. 3. SEE FINISH ELEVATIONS (A3.1-A3.2)

More information

Huntington Beach City School District. M e a s u r e Q B o n d I m p l e m e n t a t i o n S i t e C o m m i t t e e M e e t i n g M a y

Huntington Beach City School District. M e a s u r e Q B o n d I m p l e m e n t a t i o n S i t e C o m m i t t e e M e e t i n g M a y Huntington Beach City School District M e a s u r e Q B o n d I m p l e m e n t a t i o n S i t e C o m m i t t e e M e e t i n g M a y 0 1 7 Agenda 1. Where are we in the process?. Measure Q Bond Program

More information

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES: CONTACT INFORMATION: SHEET INDEX: DISCLOSURES: DOCUMENT GENERAL NOTES: CLIENT ARDENT RESIDENTIAL 5453 BURNET RD. SUITE 203 AUSTIN, TX 78756 ARCHITECT DAVIES COLLABORATIVE 5453 BURNET RD. SUITE 202 AUSTIN,

More information

PRESENT: Dr. George Mannon TUSD Superintendent Dr. Donald Stabler TUSD Deputy Superintendent. Marybeth Spadafino Committee Member: Admin.

PRESENT: Dr. George Mannon TUSD Superintendent Dr. Donald Stabler TUSD Deputy Superintendent. Marybeth Spadafino Committee Member: Admin. MEETING DATE: March 22, 2010 PROJECT: Bert Lynn Middle School Modernization Site Committee Meeting #5 HMC PROJECT #: 3203-037-000 PRESENT: Dr. George Mannon TUSD Superintendent Dr. Donald Stabler TUSD

More information

Arnolfini Access Statement

Arnolfini Access Statement Arnolfini Access Statement Image 1: Arnolfini from the water About Arnolfini In a fantastic waterside location at the heart of Bristol s harbourside, Arnolfini is one of Europe s leading centres for the

More information

Last updated 8/26/2013

Last updated 8/26/2013 ADA Tolerances Provisions Last updated 8/26/2013 This website is being developed by Evan Terry Associates to try to answer common questions about the proper use of conventional industry tolerances as defined

More information

A. Submit properly identified manufacturer's literature before starting work.

A. Submit properly identified manufacturer's literature before starting work. SECTION 10400 IDENTIFYING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Labor and materials required for installation of plaque, school name and address numbers, directional signage, signage

More information

WASHROOM ACCESSORIES 2013 CATALOG

WASHROOM ACCESSORIES 2013 CATALOG WASHROOM ACCESSORIES 2013 CATALOG Washroom Accessories engineered for the high traffic restroom. 12-14 GAUGE STAINLESS STEEL 1 Paper Towel Dispenser C-Fold or Multi-Fold Towels Refill indicator slot Heavy

More information

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI) ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI) PROJECT: Villa Joseph Marie High School - Auditorium Addition ARCHITECTS PROJECT NO: 2339 ASI NO: 001 DATE OF ISSUANCE: 12/5/2017 TO: Twining Construction Co.

More information

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON The City of Vaughan Procurement Services Department 2141 Major Mackenzie Drive Vaughan, ON L6A 1T1 Tel (905) 832-8555 ADDENDUM NOTICE ADDENDUM NO. 3 Total of (5) page BID NO. T18-003 DESCRIPTION: INTERIOR

More information

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018 SYMBOLS STANDARD DRAWINGS INDEX No Statewide Standard - Use Regional A3 Legend Detail Sheet BRIDGE AND STRUCTURES B-08.00 Bin Walls 1 CONSTRUCTION-BARRICADES AND SIGNING C-04.12 Location of Double Traffic

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Special-Lite Restroom Partitions IMPORTANT - BEFORE YOU START... 1. Read through these installation instructions first to understand the order of work. 2. Check all components

More information

atm installation for accessibility a guide to ada/aba accessibility guidelines

atm installation for accessibility a guide to ada/aba accessibility guidelines atm installation for accessibility a guide to ada/aba accessibility guidelines WARNING This document supersedes all other information provided by Triton for ATM Installation for accessibility. Information

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International Code Council, Falls

More information

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item

More information

Marcus Moziah Garvey Elementary School

Marcus Moziah Garvey Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2004 FLORIDA RESIDENTIAL STAIR BUILDING CODE (with 2005 amendments) Portions of this document reproduce sections from

More information

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September

More information

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643 11 W 9th St Chicago, IL 3 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will

More information

A. Submit manufacturer's technical data and installation for each type of sign required.

A. Submit manufacturer's technical data and installation for each type of sign required. SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room

More information

Philip Rogers Elementary School 7345 N Washtenaw Ave Chicago, IL 60645

Philip Rogers Elementary School 7345 N Washtenaw Ave Chicago, IL 60645 34 Washtenaw Ave Chicago, IL 04 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report

More information

CAC MEETING, FEB. 28 TH, 2017 NADAAA

CAC MEETING, FEB. 28 TH, 2017 NADAAA ADAMS STREET BRANCH LIBRARY PROGRAMMING STUDY FOR CITY OF BOSTON BOSTON PUBLIC LIBRARY AND PUBLIC FACILITY DEPARTMENT CAC MEETING, FEB. 28 TH, 2017 NADAAA 1 AGENDA 1.0 SCHEDULE 2.0 SUMMARY OF PROJECT GOAL

More information

*********************************************************************************************************

********************************************************************************************************* 10400 IDENTIFYING DEVICES ********************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 10 14 00 *********************************************************************************************************

More information

ADA-COMPLIANT SAFETY DEVICES PRODUCT GUIDE. SafetyRail TM Barricade SafetyWall TM Barricade BoardWalk Temporary RAMP

ADA-COMPLIANT SAFETY DEVICES PRODUCT GUIDE. SafetyRail TM Barricade SafetyWall TM Barricade BoardWalk Temporary RAMP ADA-COMPLIANT SAFETY DEVICES PRODUCT GUIDE SafetyRail TM Barricade SafetyWall TM Barricade BoardWalk Temporary RAMP SafetyWall TM ADA-COMPLIANT PEDESTRIAN BARRICADE Ideal for creating accessible work zones.

More information

SECTION IDENTIFYING DEVICES

SECTION IDENTIFYING DEVICES SECTION 10400 IDENTIFYING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Labor and materials required for installation of plaque, school name and address numbers, directional signage, signage

More information

Access Statement for Gladstone Pottery Museum

Access Statement for Gladstone Pottery Museum Access Statement for Gladstone Pottery Museum This access statement does not contain personal opinions as to our suitability for those with access needs, but aims to accurately describe the facilities

More information

Everett McKinley Dirksen Elementary School

Everett McKinley Dirksen Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

CKBD Peakes Bath Scoresheet

CKBD Peakes Bath Scoresheet CKBD Peakes Bath Scoresheet Part I: Graphics & Presentation Standards Each question pertains to all four drawing documents: Floor Plan, Mechanical, Construction Plan, and Elevation Drawing unless specifically

More information

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11 Mighty Mo GX Series Cabinet Installation Guide OR-71601787 Safety and Warning ATTENTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND DIRECTIVE 1C-12 Issue date: August 2012 1. General SURVEY, MAPPING AND UTILITY LOCATING This Directive has been developed as a general guide for the survey and mapping effort required for Fund projects.

More information

Jackie Robinson Elementary School

Jackie Robinson Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

IN T E R N A T I O N A L

IN T E R N A T I O N A L Visual Interpretation Of The IN T E R N A T I O N A L RE S I D E N T I A L CO D E 2000 STAIR BUILDING CODE SECTION R314 STAIRWAYS R314.1 Width. Stairways shall not be less than 36 inches (914 mm) in clear

More information

ADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS

ADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS ADDENDUM NO. TWO To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS Prepared By: ARCHITECT Bhide & Hall Architects, P.A. 1329-C Kingsley

More information

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING INFORMATION BULLETIN / GENERAL INFORMATION REFERENCE NO.: None DOCUMENT NO. P/GI 2014-007 Previously Issued As: P/GI 2011-007 Effective: 01-01-2014 Revised: DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY

More information

March 1, Courtney Wilton Portland Public Schools 501 North Dixon Portland, OR 97227

March 1, Courtney Wilton Portland Public Schools 501 North Dixon Portland, OR 97227 March 1, 2017 Courtney Wilton Portland Public Schools 501 North Dixon Portland, OR 97227 Via email: Regarding: cwilton@pps.net Lead Paint Condition Assessment Sunnyside School 3421 SE Salmon Street Portland,

More information

CHECKLIST FOR CHURCH FACILITY MANAGERS: EVALUATE YOUR CHURCH FACILITIES THROUGH THE EYES OF VISITORS

CHECKLIST FOR CHURCH FACILITY MANAGERS: EVALUATE YOUR CHURCH FACILITIES THROUGH THE EYES OF VISITORS CHECKLIST FOR CHURCH FACILITY MANAGERS: EVALUATE YOUR CHURCH FACILITIES THROUGH THE EYES OF VISITORS As a facility manager, part of your mission is to help your church grow by maintaining facilities that

More information

EPIC Academy High School

EPIC Academy High School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

SUPPLEMENT 2 TO SECTIONS 14 & 15

SUPPLEMENT 2 TO SECTIONS 14 & 15 assurance. SUPPLEMENT 2 TO SECTIONS 14 & 15 DESIGN SERIES ELEVATIONS SUPPLEMENT - 2 CABINET DESIGN SERIES - CDS THE FOLLOWING CASEWORK ILLUSTRATIONS ARE ADOPTED AS DESIGN STANDARDS AND PROVIDED TO ASSIST

More information

BASEBALL PLAYER FACILITIES CLEMSON, SOUTH CAROLINA

BASEBALL PLAYER FACILITIES CLEMSON, SOUTH CAROLINA THROUGH THE YEARS THROUGH THE YEARS VIEW FROM RIGHT FIELD VIEW FROM DUGOUT VIEW FROM NEW GRANDSTAND EXISTING CONDITIONS EXTERIOR PHOTOS PLAYER S LOUNGE LOCKER ROOM TRAINING AREA COACH S OFFICE CORRIDOR

More information

grab BarS and rails 800 SerieS

grab BarS and rails 800 SerieS grab BarS and rails 800 SerieS All Bradley Grab Bars are designed for safety and security of the physically disabled. The safety clearance feature is highly recommended by Barrier-Free design experts and

More information

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS SECTION 3 IMPROVEMENT PLAN REQUIREMENTS CONTENTS Page 3-1 Digital Submittals 3-2 3-2 Paper Size and Scale 3-2 3-3 Drafting Standard 3-2 3-4 Title Sheet 3-2 3-5 Title Block 3-3 3-6 Drainage, Sewer, Water,

More information

Specialty Detention Products

Specialty Detention Products Institutional Furniture ViewAll Wire Mesh/ Screening Safe-T-Feed Leading Innovator of Security Products for Over 80 Years Specialty Detention Products Trussbilt manufactures a variety of specialty detention

More information

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available. SECTION 105113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Owner s Maintenance Section

Owner s Maintenance Section Owner s Maintenance Section Table of Contents Heavy Duty 1. Arm Loosening 2. Weather Changes & Closing Speed Adjustments 3. Door Out of Plumb Offset 4. Door Out of Plumb Center Hung 5. Door Sagging Vertical

More information

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607 Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10441 (10 14 00) SIGNAGE A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section,

More information

THE FOLLOWING ITEMS WERE DISCUSSED: 1. HVAC SYSTEM:

THE FOLLOWING ITEMS WERE DISCUSSED: 1. HVAC SYSTEM: 4900 Lang Ave NE Albuquerque, NM 87109 505-348-4000 phone 505-348-4055 fax Meeting Minutes Project: Valley View Elementary School Owner: Valley View Public Schools / PSFA Albuquerque Colorado Springs Denver

More information

St. John s United Methodist Church Facility Stewardship Plan Last update: 9 May 2011

St. John s United Methodist Church Facility Stewardship Plan Last update: 9 May 2011 As responsible stewards of our facility, this list is maintained by the trustees to identify tasks we need to have completed to keep our church well groomed and attractive to present a welcoming, safe,

More information

PATHWAY 3G MODULAR ACCESS SYSTEM

PATHWAY 3G MODULAR ACCESS SYSTEM PATHWAY 3G MODULAR ACCESS SYSTEM TECHNICAL & ARCHITECTURAL SPECIFICATIONS Manufactured in the USA Homecare Products, Inc. All rights reserved. All text and images contained in this document are proprietary

More information

CITY OF SCHENECTADY NEW YORK CITY PLANNING COMMISSION

CITY OF SCHENECTADY NEW YORK CITY PLANNING COMMISSION CITY OF SCHENECTADY NEW YORK CITY PLANNING COMMISSION Christine S. Primiano, Principal Planner Room 14, City Hall, Jay Street SCHENECTADY, NY 12305-1938 518.382.5147 cprimiano@schenectadyny.gov www.cityofschenectady.com

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

APPENDIX 3-CLASSROOMS (review by MB) General Guidelines- All Classrooms

APPENDIX 3-CLASSROOMS (review by MB) General Guidelines- All Classrooms APPENDIX 3-CLASSROOMS (review by MB) General Guidelines- All Classrooms A.Normally, install chalkboard??????/markerboards on the front wall of the classroom. Review the specific requirements and placement

More information

EASY-IN POOL STEP SYSTEM NE132

EASY-IN POOL STEP SYSTEM NE132 EASY-IN POOL STEP SYSTEM NE132 This instruction manual features multiple guides for the step unit components. 7939 EASY POOL STEP (NE113) FOR USE WITH: EASY-IN POOL STEP (NE126) 6492 PARTS & HARDWARE FOR

More information

DRC Page 1. DOWNTOWN SAVANNAH 1 E. Broughton Street Savannah, GA New Build Program CHS.NB.431. Drawing # B78790

DRC Page 1. DOWNTOWN SAVANNAH 1 E. Broughton Street Savannah, GA New Build Program CHS.NB.431. Drawing # B78790 CHS.NB.431 New Build Program DOWNTOWN SAVANNAH 06.25.18 RS Revised E02, E05, E06, E07, E08. Added Option 2 for E04. 07.10.18 RS Revised E04, Removed Option 2. Drawing # DRC Page 1 Aerial Plan 2 DRC Page

More information

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements

More information

Wendell Smith Elementary School

Wendell Smith Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

TO WHOM IT MAY CONCERN:

TO WHOM IT MAY CONCERN: TO WHOM IT MAY CONCERN: A lot of questions are asked throughout the year as to when a building permit is required. This list may help identify some of the instances when a permit would be required: Permit

More information

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO PAGE PROJECT NO. 0-0 0 0 0 0 0 DATE: PROJECT: GATEWAY STEM ATHLETICE FIELD ALTERATIONS GATEWAY STEM HIGH SCHOOL - ST. LOUIS PUBLIC SCHOOLS 0 MCRTEE AVENUE ST. LOUIS, MISSOURI 0 TO BID DOCUMENTS DATED DECEMBER,

More information

SECTION SIGNAGE

SECTION SIGNAGE SECTION 10 14 00 SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply

More information

Sitting Height Base Cabinets

Sitting Height Base Cabinets Sitting Height Base Cabinets Signature Series 30" These Sitting Height Cabinets are 30" high and a deep. engths as shown. Open and Cupboard cabinets have one adjustable shelf. Open Cubbie cabinets have

More information

University of Chicago - North Kenwood/Oakland 1119 E 46th St Chicago, IL Co-locating on this campus are U OF C - NKO and ARIEL

University of Chicago - North Kenwood/Oakland 1119 E 46th St Chicago, IL Co-locating on this campus are U OF C - NKO and ARIEL Facility Assessment Report 9 E 4th St Chicago, IL 03 This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will

More information

11/29/12. Des Moines Social Club Urban Design Review Project Narrative

11/29/12. Des Moines Social Club Urban Design Review Project Narrative 11/9/1 Des Moines Social Club Urban Design Review Project Narrative Strategically located at 9th and Walnut, the Des Moines Social Club (DMSC) will become a critical link between the Court Avenue Entertainment

More information

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

The following information supplements and/or supersedes the bid documents issued on July 10, 2017. Addendum No. 02 ADDENDUM Pages 2 Project No. 1706 Date: July 21, 2017 Project: West End Lofts 44 MacDonald Street, Arnprior, ON The following information supplements and/or supersedes the bid documents

More information

ADA Barrier-Free Bathware for Assisted Living

ADA Barrier-Free Bathware for Assisted Living This continuing education program is sponsored and provided to you due to the professional courtesy of: ADA Barrier-Free Bathware for Assisted Living Clarion Bathware 44 Amsler Ave. Shippenville, PA 16254

More information

Amos Alonzo Stagg Elementary School

Amos Alonzo Stagg Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

SECTION IDENTIFYING DEVICES

SECTION IDENTIFYING DEVICES PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10441 IDENTIFYING DEVICES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section,

More information

H HD Adult Wheelchair Swing Frame & Hangers(perm) IMPORTANT

H HD Adult Wheelchair Swing Frame & Hangers(perm) IMPORTANT Page 1 IMPORTANT PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING ASSEMBLY. All equipment must be installed in accordance with these instructions. Check your shipment against Bill of Lading and Parts list.

More information

Architecture, Construction, and Engineering Technical Charter

Architecture, Construction, and Engineering Technical Charter Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

10. Vents, Baffle Guard and Blocking

10. Vents, Baffle Guard and Blocking 10. Vents, Baffle Guard and Blocking 10.1 INSTALLING BATH FAN AND END CAP 10.2 INSTALLING RANGE PLENUM AND END CAP 10.3 INSTALLING PROPER VENTS 10.4 INSTALLING WIND WASHING BAFFLE GUARD 10.5 INSTALLING

More information

1. Denver Water is not the provider. [C1 Cover] Baseline Response: Revised to show Thornton Water Department as the provider.

1. Denver Water is not the provider. [C1 Cover] Baseline Response: Revised to show Thornton Water Department as the provider. Nate Hatleback Project Manager City of Thornton 303 538 7694 Nate.Hatleback@cityofthornton.net Re: Topgolf Review The City of Thornton has provided comments regarding several submittals on June 14 th,

More information

WINDY HILL PROPERTY VENTURES

WINDY HILL PROPERTY VENTURES A Planning Application For: RD AVENUE & RAILROAD AVENUE SAN MATEO, CA 0 PROJECT DATA PROJECT TEAM OWNER NAME: PROJECT ADDRESS: RD AVENUE & RAILROAD AVENUE SAN MATEO, CA 0 BUILDING AREA, OFFICE: TOTAL RESIDENTIAL

More information

Philip Rogers Elementary School

Philip Rogers Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP 1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of

More information

DIVISION Hardware

DIVISION Hardware FORMAT 1. Technical specifications content and numbering system shall be based on the most current CSI Master Format. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project

More information

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360) CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION

More information

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233 INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233 QCI5233 Rev 0 Page 1 Certified 06/20/2016 INSTALLATION NOTES: Unpack your unit carefully and inspect for freight damage. Lay

More information

Preference Collection 5543 Central Console INSTALLATION GUIDE

Preference Collection 5543 Central Console INSTALLATION GUIDE Preference Collection 5543 Central Console INSTALLATION GUIDE WARNING Failure to install the 5543 as described in this installation guide may cause the unit to collapse, resulting in serious injury to

More information