REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map
|
|
- Karin Elliott
- 6 years ago
- Views:
Transcription
1 Electrical Information Breaker Panel 1: Service Type: 120/208 Panel Type: LP2 Panel Number: CHH31500 Manufacturer: Cutler Hammer Amps: 150 Location: Back Room Breaker Panel 2: Service Type: 120/208 Panel Type: LP1 Panel Number: CHH31500 Manufacturer: Cutler Hammer Amps: 125 Location: Back Room Breaker Panel 3: Service Type: 120/208 Panel Type: Type 1 Panel Number: TLM8125 Manufacturer: Cutler Hammer Amps: 125 Location: Back Room Breaker Panel 4: Service Type: 120/208 Panel Type: M50 Panel Number: FDPS367T Manufacturer: Cutler Hammer Amps: 800 Location: Back Room Exterior Disconnect Information 1: Amps: 100 Panel Type: P Panel Number: Manufacturer: Cutler Hammer Location: Back Room HVAC Information: Unit: 1 Manufacturer: Carrier Model: 48HDE Serial: 0289G18938 Tonnage: 7.5 Year: 1989 Unit: 2 Manufacturer: Carrier Model: 48HDE Serial: 0289G18902 Tonnage: 7.5 Year: 1989 Unit: 3 Manufacturer: Carrier Model: 48HDE Serial: 0289G18940 Tonnage: 7.5 Year: 1989 Unit: 4 Manufacturer: Carrier Model: 48HDE Serial: 0289G18901 Tonnage: 7.5 Year: ' 12' 14' 93' REAR 7'-5" 30'-6" 23' 5'-1" 14' 6'-11" 7'-4" 9'-4" 11'-8" 12'-5" 17' 6'-10" 6'-5" 7'-3" 6'-5" 20' 12' 27'-10" 9' 7'-11" 9' 10'-6" 48' Sample Shopping Center Revisions 100 Sample Street Sample Town, NY /- 10,920 GLA Width +/- 105' Depth +/- 120' Exterior Disconnect Information 2: Amps: 30 Panel Type: P Panel Number: Manufacturer: Cutler Hammer Location: Back Room Ceiling Information: Height from Floor to Ceiling: Front: 11' 6" Back: 11' 6" Floor to Bottom of Deck: Front: 17' 7" Back: 16' 2" Floor to Bottom of Joist: Front: 15' 9" Back: 14' 11" 104'-6" 44' 52' 30' Site Map Prepared 10/2/2017 Fire Information: Riser Location: Back Room Sprinkler Heads Present: Yes Number of Sprinkler Heads: 92 Fire Alarm Control Panel: Present: Yes Brand: Altronix Model: MS230 37'-2" 7'-7" 7' 9' 4'-5" 5'-3" 17'-9" 19'-3" 14'-4" Water Heater Information: Gallons: 40 Water Line (in): 3/4" Manufacturer: A.O. Smith Model: Unreadable Location: Located above Men's Restroom Backflow Information: Number: N/A Size: N/A Location: No Backflow Present 1 GROUND FLOOR 75' FRONT 0' 6' 12' 18' Plans produced by: ID Plans 1035 East Brandon Blvd. Brandon, FL Phone: (866) IDPlans.com 2017 Site map is for general use and purposes only. ID Plans does not guarantee the accuracy or validity of provided information. Measurements are not intended to be architecturally valid for construction purposes or accepted as replacement for documents, drawings, or media intending or claiming to be structurally accurate, such as site blueprints. The property owner has and reserves the right and responsibility to verify, change, or alter the provided information at any time for any reason.
2 SPACE PROFILE FOR Sample Shopping Center 10,920 Square Feet 1035 E. Brandon Blvd. Brandon, FL IDPlans.com [p] [f]
3 SPACE PROFILE Sample Shopping Center Unit Address: 100 Sample Road Sample Town, NY Reference # Meter # Electric Gas 1 M Water HVAC Units & Information Unit # Space # Manufacturer Model # Tonnage Serial # Year 1 5 CARRIER 48HDE G CARRIER 48HDE G CARRIER 48HDE G CARRIER 48HDE G Plans produced by: ID Plans 8/29/2017 (813) C 2017
4
5 ft Ladder 157 ft Detail Plan ± ' ft Lease Line Sample Shopping Center ± 20' ± 12' ± 120' Lease Line Ladder ± 48' Lease Line ± 30' ± 52' ± ' ft Lease Line
6 6' 5" Women's Restroom Width: 6' 5" Length: 6' 10 1/2" Area sq ft Perimeter 26' 7" 6' 10" 3' 3' 5" 6' 5" 6' 10"
7
8 ADA Reference Description Compliant Comments Signage Sample Shopping Center Women's Restroom Sign with ADA symbol Yes Raised characters Yes Braille Yes Located at latch side of door Yes Mounting height: 48"-60" Yes Restroom Entrance Door opening width: 32" min. when open 90 Yes " on pull side of door plus 60" clear Yes Accessible handles (operable by closed fist) Yes Handle height: 34"-48" Yes , Threshold: 1/4" H max. or 1/4"+1/4" beveled N/A Vestibule: 48" min. plus width of doors N/A Inside Restroom , Clear floor space: 60" diameter circle Yes Toilet centerline from wall: 16"-18" Yes Toilet clear floor space: 60" from side wall and 56" from rear wall Yes Height of toilet seat: 17"-19" Yes Height of flush control: 15"-48" Yes Flush control located on open side of toilet Yes Side wall grab bar: 42" L, 12" max. from wall Yes Side wall grab bar: 33"-36" H to top Yes Rear wall grab bar: 36" L, 12" & 24" toilet No Rear wall grab bar: 33"-36" H to top Yes TP dispenser: 7"-9" from front of toilet to Yes Height of TP dispenser: 15"-48" Yes TP dispenser not located behind grab bar Yes Sink clear floor space: 30" W x 48" D Yes Height of sink rim: 34" max. Yes Knee clearance: 27" H min. x 8" D min. Yes Pipe protection below sink Yes Faucet handles: operable by closed fist Yes Bottom of mirror: 40" H max. if over sink Yes Bottom of mirror: 35" H max. if not over sink N/A Soap dispenser: 44" H max. if above sink N/A Soap dispenser: 48" H max. not above sink Yes , Paper towel dispenser: (same as soap) N/A , Electric hand dryer: (same as soap) N/A Toilet Compartments (Stalls) Door opening width: 32" min. when open 90 N/A " on pull side of door N/A Is stall door self-closing N/A Door lock: operable by closed fist N/A Height of door lock: 34"-48" N/A Stall width: 60" min. N/A Stall depth: 56" min. wall hung toilet* N/A Stall depth: 59" min. floor mounted toilet* N/A *Note: add door swing if door swings in Height of flush control: 15"-48" N/A
9 Men's Restroom Width: 6' 5" Length: 7' 3" Area sq ft Perimeter 27' 4 1/2" 7' 3" 3' 10" 3' 6' 5" 6' 5" 7' 3"
10
11 ADA Reference Description Compliant Comments Signage Sample Shopping Center Men's Restroom Sign with ADA symbol Yes Raised characters Yes Braille Yes Located at latch side of door Yes Mounting height: 48"-60" Yes Restroom Entrance Door opening width: 32" min. when open 90 Yes " on pull side of door plus 60" clear Yes Accessible handles (operable by closed fist) Yes Handle height: 34"-48" Yes , Threshold: 1/4" H max. or 1/4"+1/4" beveled N/A Vestibule: 48" min. plus width of doors N/A Inside Restroom , Clear floor space: 60" diameter circle Yes Toilet centerline from wall: 16"-18" Yes Toilet clear floor space: 60" from side wall and 56" from rear wall Yes Height of toilet seat: 17"-19" Yes Height of flush control: 15"-48" Yes Flush control located on open side of toilet Yes Side wall grab bar: 42" L, 12" max. from wall Yes Side wall grab bar: 33"-36" H to top Yes Rear wall grab bar: 36" L, 12" & 24" toilet No Rear wall grab bar: 33"-36" H to top Yes TP dispenser: 7"-9" from front of toilet to Yes Height of TP dispenser: 15"-48" Yes TP dispenser not located behind grab bar Yes Sink clear floor space: 30" W x 48" D Yes Height of sink rim: 34" max. Yes Knee clearance: 27" H min. x 8" D min. Yes Pipe protection below sink Yes Faucet handles: operable by closed fist Yes Bottom of mirror: 40" H max. if over sink Yes Bottom of mirror: 35" H max. if not over sink N/A Soap dispenser: 44" H max. if above sink N/A Soap dispenser: 48" H max. not above sink Yes , Paper towel dispenser: (same as soap) N/A , Electric hand dryer: (same as soap) N/A Toilet Compartments (Stalls) Door opening width: 32" min. when open 90 N/A " on pull side of door N/A Is stall door self-closing N/A Door lock: operable by closed fist N/A Height of door lock: 34"-48" N/A Stall width: 60" min. N/A Stall depth: 56" min. wall hung toilet* N/A Stall depth: 59" min. floor mounted toilet* N/A *Note: add door swing if door swings in Height of flush control: 15"-48" N/A
12
13
14
15
16 Space Profile National Pricing Size of Space Price per Space Under 2,000 SF $ ,000-20,000 SF $1, Over 20,000 SF $0.06 per SF
17 Contact Us to Learn More about Space Profiles* (813) ext. 124 *Add-on storefront plans, window plans, and exterior building dimensions available upon request. Please inquire with our sales team.
Priority 3 - Toilet Rooms
The ADA Checklist for Readily Achievable Barrier Removal Priority 3 - Toilet Rooms Project Building Location Date Surveyors Contact Information When toilet rooms are open to the public they should be accessible
More informationPriority 3 - Toilet Rooms
The ADA Checklist for Existing Facilities Priority 3 - Toilet Rooms Based on the 2010 ADA Standards for Accessible Design Project Building Location Date Surveyors Contact Information When toilet rooms
More information2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES
City Of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA BUILDING CODE - SECTION 11B-213
More informationWEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5
Page 1 of 5 When toilet rooms are provided, each toilet room shall comply with Section 11B-213.2 of the California Building Code. Unisex toilet rooms (Single-use or family) shall contain not more than
More informationACCESSIBILITY REQUIREMENTS FOR SINKS
ACCESSIBILITY REQUIREMENTS FOR SINKS 1. Max. Height to top of counter at sink 2. Min. toe clearance 3. Plan view of 30 x48 clear space and depth 4. Min. knee clearance 5. Plan view of 30 x48 clear space
More informationNCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice
NCIDQ Restroom Drawing Answers to the most common questions about this drawing for the Practicum. 2016 Qpractice Table of Contents This is a summary guide of most frequently asked questions about the Practicum
More informationKEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}
KEYS TO COMPLIANCE : Grab bars are required to be at a height of 33 to 36 inches. A117.1 and 2010 Standards measure to the top of the graspable surface. Graphics in ADAAG and earlier editions of A117.1
More informationWALKS AND SIDEWALKS REQUIREMENTS:
DOUBLE PARKING STALLS DIAGONAL PARKING STALLS EXTERIOR ROUTES OF TRAVEL: From accessible parking spaces, provide most practical direct accessible route of travel to all building entrances and exteriorground
More informationAccessible Toilet Stalls 6/18/03 1
Accessible Toilet Stalls 6/18/03 1 Section 11-4.17 Toilet Stalls Florida standard stall (11-4.17.3.1) In new construction the standard accessible stall shall contain an accessible lavatory within it, the
More informationACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec.11B-305,604,605 Effective: 01/01/2017 DOCUMENT NO.: P/BC 2017-087 Revised: Previously Issued As: P/BC 2014-087 ACCESSIBILITY DETAILS
More informationA.1 KING RESTROOM DEMOLITION PLAN. KING PARK 725 Monte Diablo Ave, San Mateo, CA LEGEND A.2 4 SCALE:
LEGEND EXISTING DEMO MEN'S WOMEN'S "STORAGE" "STORAGE" A.2 4 SCALE: KING DEMOLITION PLAN 4" = ' - 0" N COMPLIANCY NOTES - 30" MIN CLEARANCE FOR SINK WIDTH - DIAMETER FOR WHEELCHAIR ROTATION - 30" x 48"
More informationCKBD Peakes Bath Scoresheet
CKBD Peakes Bath Scoresheet Part I: Graphics & Presentation Standards Each question pertains to all four drawing documents: Floor Plan, Mechanical, Construction Plan, and Elevation Drawing unless specifically
More informationPaper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers
Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers 4.2.5* Forward Reach. If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48
More informationGRAF HALL ADA ASSESSMENT & SURVEY
OREGON STATE UNIVERSITY (OSU) GRAF HALL ADA ASSESSMENT & SURVEY Sacramento Office 770 L Street, Suite 950 Sacramento, CA 95814 Tel: 916.669.8750 Fax: 888.211.7441 Silicon Valley Office 2225 E. Bayshore
More informationDRC Page 1. DOWNTOWN SAVANNAH 1 E. Broughton Street Savannah, GA New Build Program CHS.NB.431. Drawing # B78790
CHS.NB.431 New Build Program DOWNTOWN SAVANNAH 06.25.18 RS Revised E02, E05, E06, E07, E08. Added Option 2 for E04. 07.10.18 RS Revised E04, Removed Option 2. Drawing # DRC Page 1 Aerial Plan 2 DRC Page
More informationTO WHOM IT MAY CONCERN:
TO WHOM IT MAY CONCERN: A lot of questions are asked throughout the year as to when a building permit is required. This list may help identify some of the instances when a permit would be required: Permit
More information214 Wilshire Blvd., Suite 102 Santa Monica California 90401
Wilshire Blvd., Suite 0 Santa Monica California 900 7 W a l l a c e P l. C a l i f o r n i a 9 8 t e l : 0 7 7 N ND COURT PROPERTY LINE 0.00' THE RENOVATION AND CHANGE OF USE OF AN EXISTING BOOK STORE
More informationPhoto Guide. Section A: Standard Sunoco Photos. 1. Overall Restroom photo details: 2. Overall Pump photo details:
Photo Guide Overview: This is a basic field guide to Sunoco mystery shop photo requirements. A more in-depth explanation of photo requirements can be found in the Sunoco instructional presentation. It
More informationGalaxy Corporate Center
Galaxy Corporate Center Flex Space Galaxy Corporate Center Galaxy Parkway Warrensville Heights, Ohio Jeffrey Kahn,, For Lease 4,546 + Square Feet 25111 Miles Road 25111 Miles Road Warrensville Heights,
More informationADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON
The City of Vaughan Procurement Services Department 2141 Major Mackenzie Drive Vaughan, ON L6A 1T1 Tel (905) 832-8555 ADDENDUM NOTICE ADDENDUM NO. 3 Total of (5) page BID NO. T18-003 DESCRIPTION: INTERIOR
More informationID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:
CONTACT INFORMATION: SHEET INDEX: DISCLOSURES: DOCUMENT GENERAL NOTES: CLIENT ARDENT RESIDENTIAL 5453 BURNET RD. SUITE 203 AUSTIN, TX 78756 ARCHITECT DAVIES COLLABORATIVE 5453 BURNET RD. SUITE 202 AUSTIN,
More informationATLAS. $12.00 psf NNN 5,937 SF RETAIL FOR LEASE: 2929 California Plaza Omaha, Nebraska * * CERTIFIED *
FOR LEASE: ATLAS 2929 California Plaza Omaha, Nebraska $12.00 psf NNN 5,937 SF HIGHLIGHTS Great opportunity to be located on the first floor of a new development with over 700 apartments underway! Join
More informationBluerock Center LONE TREE WAY > ANTIOCH, CA > OFFICE > RETAIL
Project Summary BLUEROCK CENTER in Antioch, CA is a Class A medical, office and retail project consisting of 121,000 square feet of state of the art buildings in a campus setting. The project is located
More informationPROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic
GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable
More informationCity of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2
City of Los Angeles Plan Check No. 1. Except building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos, new or altered signs
More informationCity of Thousand Oaks
TENANT IMPROVEMENT SUBMITTAL CHECKLIST SUBMIT THREE SETS OF SCALED DRAWINGS (ONE TO BE A BLACKLINE SET) WITH THE FOLLOWING INFORMATION: 1. 2. 3. 4. 5. 6. 7. 8. 9. SITE PLAN: Show building location (vicinity
More informationApril 7, City of Verona Adam Sayre, AICP Director of Planning & Development 111 Lincoln St. Verona, WI 53593
April 7, 2016 City of Verona Adam Sayre, AICP Director of Planning & Development 111 Lincoln St. Verona, WI 393 RE: Conditional Use Arby s Restaurant Multi-Tenant Development 631 Hometown Circle-Lot 6
More informationResidential Construction Checklist Single and Two Family Construction
DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy
More informationORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 11/02/2012 BUILDING SURVEY DATE
0201 1701 SOUTH OAK STREET CHAMPAIGN, ILLINOIS 61820 SYSTEM CONDITION INDEX.116 PRIMARY BUILDING USE BUILDING SURVEY TEAM BUILDING SYSTEM REPLACEMENT COST $ 1,734,300 PARKING STRUCTURE BUILDING GROSS SQUARE
More informationInstallation Instructions
AMPCO Solid Plastic Toilet Partitions AMPCO Florida 11400 NW 36 th Avenue Miami, FL 33167 T. 305.821.5700 florida@ampco.com AMPCO Texas 201 Railroad Avenue Sanger, TX 76266 T. 940.458.7401 texas@ampco.com
More informationwww.mountaincovehomes.com HOME FEATURES STRUCTURAL ELEMENTS Reinforced concrete monolithic foundation slab Concrete masonry block exterior walls Professionally engineered roof and floor trusses with hurricane
More informationSECTION PLUMBING FIXTURES
SECTION 224000 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Faucets for lavatories and sinks. 2. Flushometers. 3. Toilet seats. 4. Protective shielding guards. 5. Fixture
More informationHiram H Belding Elementary School 4257 N Tripp Ave Chicago, IL 60641
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationTHE SHOPS AT ROSSMOOR NWC St Cloud Drive & Seal Beach Blvd, Seal Beach, CA
THE SHOPS AT ROSSMOOR NWC St Cloud Drive & Seal Beach Blvd, Seal Beach, CA JOIN Restaurant ready space Endcap with great frontage and visibility 3,299 SF 120-208 volt, 3-phase, 4-wire, 600-amp, 3 gas line,
More informationInstallation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:
Installation Manual Solid Plastic Toilet Partitions Toilet Partitions & Lockers IN THE U.S.A.: Hadrian Inc., 7420 Clover Avenue, Mentor, OH 44060 Telephone: 440-942-9118 Fax: 440-942-9618 U.S. toll free
More informationARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)
ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI) PROJECT: Villa Joseph Marie High School - Auditorium Addition ARCHITECTS PROJECT NO: 2339 ASI NO: 001 DATE OF ISSUANCE: 12/5/2017 TO: Twining Construction Co.
More informationNorth Lawndale College Prep Charter - Collins
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More information1. Name the horizontal member that rests on the foundation wall to support other wood members.
Student Name: Teacher: Date: District: Rowan Assessment: 9_12 T and I IC62 - Drafting - Architr II Test 1 Description: Unit C - Floorplans - Test 3 (ALL) Form: 501 1. Name the horizontal member that rests
More informationRENOVATION OF THE FARMERS MARKET Reference Number:
RENOVATION OF THE FARMERS MARKET Reference Number: 13-098 A D D E N D U M NO. 1 The following shall form part of the tender documents issued by the City of Guelph s Purchasing Department, June, 2013. NOTE:
More informationSonoma Cheese Factory
WEST SPAIN STREET 1ST STREET WEST 1ST STREET EAST 0 10 25 2 W E S T S PA I N S T R E E T - S O N O M A, C A L I F O R N I A EXISTING AREA PLAN 50 100 w w w. s m s - a r c h. c o m WEST SPAIN STREET 1ST
More information107 TH & PORTAL. $ psf NNN 2,437-40,808 SF COMMERCIAL FOR LEASE Virginia Plaza Papillion, Nebraska * * CERTIFIED *
COMMERCIAL FOR LEASE 107 TH & PORTAL 10717 Virginia Plaza Papillion, ebraska $8.95-12.55 psf 2,437-40,808 SF HIGHLIGHTS Flex/Retail building available Spring 2019 All bays have a drive in door Less than
More information*********************************************************************************************************
10400 IDENTIFYING DEVICES ********************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 10 14 00 *********************************************************************************************************
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information on last page. Review
More informationCharles N Holden Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationChurch Street and Monroe Road Sanford, Florida 32771
Phase I & II Office / Warehouse Space Church Street and Monroe Road Property Features (5) grade level office / warehouse buildings totaling 116,500± SF 12 x 14 grade-level overhead doors Clear height:
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.
INFORMATION INSTRUCTIONS CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO. 2 PROJECT NO.: EXPIRATION DATE: STATUS:
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS COMPACT LAMINATE TOILET PARTITIONS 1080 DuraLineSeries 1180 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information
More informationMarcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643
Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item
More informationInstallation. *HDWC-INSTR-007* HDWC-INSTR-007 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018
Installation Phenolic Restroom Partitions, Ceiling-Hung Series 600 Table of Contents Pre-Installation Information... 2-3 Layout Dimensions for rackets...4 Mounting rackets to Wall... 5-6 Leveling rackets
More informationA. Submit properly identified manufacturer's literature before starting work.
SECTION 10400 IDENTIFYING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Labor and materials required for installation of plaque, school name and address numbers, directional signage, signage
More informationChurch Street and Monroe Road Sanford, Florida 32771
Phase I & II Office / Warehouse Space Church Street and Monroe Road Property Features (5) grade level office / warehouse buildings totaling 116,500± SF 12 x 14 grade-level overhead doors Clear height:
More informationTOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill
DEVICES COVERED IN THIS DOCUMENT: 4700S Surface Vertical Rod Device 4700SF Fire Exit Surface Vertical Rod Device TOOLS REQUIRED Metal Wood Wood and Metal Screws Sex Bolts #7 Drill ¼ -20 Tap #16 Drill #12-24
More informationPORTLAND COMMUNITY COLLEGE ROCK CREEK CAMPUS ELECTRICAL POWER GENERATION FEASIBILITY STUDY APPENDIX A, DETAILED (CONCEPT LEVEL) PROBABLE COST ESTIMATE
PORTLAND COMMUNITY COLLEGE ROCK CREEK CAMPUS ELECTRICAL POWER GENERATION FEASIBILITY STUDY APPENDIX A, DETAILED (CONCEPT LEVEL) PROBABLE COST ESTIMATE September 14th, 2018 Prepared by: DAO Architecture
More informationSPARTAN DAY CAMP 4814 FREEDOM RING RD
484 FREEDOM RING RD PROJECT DATA GENERAL PROJECT NOTES: LOCATION:. DIMENSIONS ARE TO FACE OF STUD OR TO COLUMN CENTERLINE UNLESS NOTED OTHERWISE. VERIFY ALL EXISTING CONDITIONS AND ADJUST WALL DIMENSIONS
More informationThe following information supplements and/or supersedes the bid documents issued on July 10, 2017.
Addendum No. 02 ADDENDUM Pages 2 Project No. 1706 Date: July 21, 2017 Project: West End Lofts 44 MacDonald Street, Arnprior, ON The following information supplements and/or supersedes the bid documents
More informationat Fiddler s Creek Offered by
at Fiddler s Creek at Fiddler s Creek hawthorne Elevation E Elevation F WWW.FIDDLERSCREEK.COM hawthorne 1 Story, 3 Bedrooms, 3 Baths, Den, 3 Car Garage Total A/C... 2,583 sq. ft. Entry...51 sq. ft. Garage...618
More information4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118
PART 1: GENERAL This section of the design standard outlines general requirements for electrical and telecommunications designs to be performed for the University of Texas at Austin. This standard is intended
More informationJames Shields Middle School 2611 W 48th St Chicago, IL 60632
2 W 48th St Chicago, IL 02 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationDE BOERS DRIVE TORONTO
FOR LEASE 20 DE BOERS DRIVE TORONTO MIXED USE LEASING: OFFICE // RETAIL // MEDICAL Please visit our website at: www.domocentre.ca HIGHLIGHTS 3 storey high common atrium, green wall and cafe Office configurations
More informationINTERIOR SIGNAGE MANUAL
INTERIOR SIGNAGE MANUAL ➊ Purpose ➋ Procedures ➌ ADA Requirements INTERIOR SIGNAGE MANUAL ➍ Text, Braille, Pictograms and Color ➎ Families of Interior Signage ➏ Mounting Guidelines ➐ Signage Diagrams ➑
More informationFIRE SPRINKLER SYSTEM SUBMITTAL CHECKLIST AND APPLICATION
PERMITS AND INSPECTIONS FIRE SPRINKLER SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number of
More informationChapter 4. Accessible Routes
ICC/ANSI A117.1-2003 401 General 401.1 Scope. Accessible routes required by the scoping provisions adopted by the administrative authority shall comply with the applicable provisions of Chapter 4. 402
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLine Series 1180 DuraLine Series Class-A Fire Rated IMPORTANT: Review these instructions thoroughly prior to installation. FLOOR ANCHORED
More informationWendell E Green Elementary School 1150 W 96th St Chicago, IL 60643
11 W 9th St Chicago, IL 3 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationQuality Control Checklist - Design Drawings
Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not
More informationConstruction Guidelines 1
Construction Guidelines 1 Addendum Log November, 2014 Full Update March, 2015 Formatting July, 2015 Editing November, 2016 Full Update February, 2017 Complete Overhaul Signage Criteria 2 Table of Contents
More informationUNIT A 879 SQ. FT. FLOORS 1 TO 4 REVERSE 879 SQ. FT. FLOORS 1 TO SQ. FT.
UNIT A 879 SQ. FT. 879 SQ. FT. REVERSE 879 SQ. FT. THE DEVELOPER AND BUILDER RESERVE THE RIGHT TO MAKE MODIFICATIONS AND CHANGES TO THE BUILDING, ANY UNIT, PARKING AREA AND STORAGE AREA DESIGN, SPECIFICATIONS,
More informationGerber Fixtures. Ultra Flush 1.6 GPF Pressure Assist Color Prod. ID Combination Bowl Tank Rough-In
2018 PAGE 108-1 Gerber Fixtures Please see www.gerberonline.com/shop for product descriptions and photos. Items in Bold are currently stocked at Roberts-Hamilton Company Prod.ID is for the Combination
More informationAPPLICATION FOR A BUILDING PERMIT
APPLICATION FOR A BUILDING PERMIT City of San Jacinto 595 S. San Jacinto Ave San Jacinto CA 92583 95.487.7330 fax 95.654.9896 Must print legibly, submit (3) sets of building and plot plans. Fill out all
More information1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.
WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 10 SPECIALTIES SECTION 101410 INTERIOR SIGNAGE PART 1 - GENERAL 1.1. Any deviance from the following requirements must be approved during design
More information03/7/12 Issuance UTD Section Page 1 of 5 Electrical General
SECTION 26 01 00 ELECTRICAL GENERAL PART 1: GENERAL 1.1 Electrical/Telecommunications Design 1.1.1 This section of the design and construction standard outlines general requirements for electrical and
More informationJackie Robinson Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationARB MEETING DATE: APRIL 17, 2017 BUSINESS NAME: 1 WALL MOUNTED SIGN 4 WALL MOUNTED, 1 FREESTANDING SQUARE FEET
ARCHITECTURAL REVIEW BOARD SIGN FORM BUSINESS NAME: WORLD FINANCE AND LOANS LOCATION: 205 N. GOOSE CREEK BLVD./STE. 104 NUMBER & TYPE OF SIGNS APPLYING FOR: NUMBER OF ALLOWABLE SIGNS: MAXIMUM ALLOWABLE
More informationFEMA Elevation Certificate
Visual 320.1 Visual EC-1 Required to rate post-firm and some pre-firm buildings Determine compliance with floodplain management ordinance Support LOMA/LOMR-F Prerequisite for the CRS Visual 320.2 Visual
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Special-Lite Restroom Partitions IMPORTANT - BEFORE YOU START... 1. Read through these installation instructions first to understand the order of work. 2. Check all components
More informationWASHROOM ACCESSORIES 2013 CATALOG
WASHROOM ACCESSORIES 2013 CATALOG Washroom Accessories engineered for the high traffic restroom. 12-14 GAUGE STAINLESS STEEL 1 Paper Towel Dispenser C-Fold or Multi-Fold Towels Refill indicator slot Heavy
More informationCOMMERCIAL VISUAL INDEX LOBBIES COMMERCIAL VISUAL INDEX NURSE S STATIONS. General Safety. General Safety. Kitchens
VISUAL INDEX NURSE S STATIONS Solid Surfacing by Formica Group 6 4 Solid Surfacing by Formica Group 65 VISUAL INDEX LOBBIES SIGNAGE Hand Rails pg 71-75 WALL APPLICATION pg 67-70 UNDERMOUNTED SINKS pg 28-31
More informationGRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO
PAGE PROJECT NO. 0-0 0 0 0 0 0 DATE: PROJECT: GATEWAY STEM ATHLETICE FIELD ALTERATIONS GATEWAY STEM HIGH SCHOOL - ST. LOUIS PUBLIC SCHOOLS 0 MCRTEE AVENUE ST. LOUIS, MISSOURI 0 TO BID DOCUMENTS DATED DECEMBER,
More informationInstallation. *HDWC-INSTR-008* HDWC-INSTR-008 Rev. H; ECN G 2018 Bradley Page 1 of 24 3/22/2018
Installation Phenolic Restroom Partitions Floor-To-Ceiling Series 700 For Standard Height Doors and Panels Only Table of Contents Pre-Installation Information... 2-3 Layout Dimensions for rackets...4 Mounting
More informationgrab BarS and rails 800 SerieS
grab BarS and rails 800 SerieS All Bradley Grab Bars are designed for safety and security of the physically disabled. The safety clearance feature is highly recommended by Barrier-Free design experts and
More informationAddress: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:
Community Development Department 10 N. Water Street Monday Friday 847 741 3894 8:30 a.m. 5:00 p.m. 847 741 3959 FAX www.southelgin.com BASEMENT REMODEL APPLICATION PROPERTY INFORMATION South Elgin, IL
More informationWayne State University. Prentis Building Renovation. NM Project Number: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009
ADDENDUM NO 2 OWNER: Wayne State University DATE: January 4 th, 2019 PROJECT: NM Project Number: 18113.0 ARCHITECT: ENGINEER: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009 IMEG 26200 Town
More informationCopyrighted report licensed to Lee & Associates /14/2017. Page 1
Copyrighted report licensed to Lee & Associates 697357. 6/4/207 Page ) Country Club Center Address Building/Park Name SF Avail Stories RBA Land Ceiling Height Drive Ins Levelators Crane Sprinkler 50 W
More informationBioPrism Solid Surface
Please read all instructions before installing products. These instructions are intended for use with InPro s standard toilet partitions, which include 58 high doors and wall panels, when deviating from
More information11SIXTY5 Weaver Dairy Road
SITEPLAN NOTES 2 C-2.0 BICYCLE RACK NTS Weaver Dairy Road Job Number: 1529 WLR, MTC, VJC WLR, VJC 11-30-17 STAIR SITE PLAN 1 C-2.0 SITE PLAN 1" = 30' 0 15 30 60 3 C-2.0 PLAZA DETAIL PLAN 1" = 20' 0 10
More informationAMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and
More informationEverett McKinley Dirksen Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationETHAN CONRAD P R O P E R T I E S I N C. REMODEL COMPLETE 270 SF - 5,840 SF OFFICE FOR LEASE WITH RETAIL VISIBILITY AND SIGNAGE
270 SF - 5,840 SF OFFICE FOR LEASE WITH RETAIL VISIBILITY AND SIGNAGE REMODEL COMPLETE FEATURES: 2233 : Available suite: Suite 270-270 SF Professional environment 2255 : Available suites ranging from 457
More informationSTEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationSCHEDULE OF MATERIALS - SPRINGTOWN UNITS
Appliances AP-200 Kitchen Refrigerator Whirlpool WRT549SZDM Stainless Steel 29"W x 34.5"D x 65-7/8"H MSRP $999.00 AP-201 Kitchen Dishwasher Whirlpool WDF320PADS Stainless Steel 23-7/8"W x 24.5"D x 34.5"H
More information152,114 SF MONROE COURT Morton Grove, IL
NOW AVAILABLE MAJOR RENOVATIONS INCLUDE: + + New Landscaping + + New Windows + + New Parking Lot + + HVAC + + T-8 Lighting + + Renovated Offices + + 1 1/2 Acre of Paved Outside Storage / Trailer Parking
More informationJuly 3, CASCO Project Managers St. Louis, Missouri PETSMART STORES. 13K Q Prototype Narrative (Delta 5) Bulletin No.
July 3, 2013 CASCO Project Managers St. Louis, Missouri PETSMART STORES 13K Q2 2013 Prototype Narrative (Delta 5) Bulletin No. Five CHANGES TO THE DRAWINGS: 1. Sheet A0.0, Revision No. 5: Revised project
More informationUNIVERSITY SERIES Fixed, Projected and Casement Steel Windows
Fixed, Projected and Casement Steel Windows Hope's University Series steel window profiles were designed for projects requiring historic replication of exterior putty glazed steel windows. The fixed and
More informationCyrus H McCormick Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationMahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620
W 88th St Chicago, IL 0 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will
More informationIMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED
INSTALLATION INSTRUCTIONS MAXIMUM PRIVACY COMPACT LAMINATE TOILET PARTITIONS 2080 DuraLineSeries 2180 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and
More informationEUROLINE CLASSIC SOLID SURFACE Installation Instructions
EUROLINE ASSIC SOLID SURFACE Installation Instructions 12/01/15 EUROLINE ASSIC SOLID SURFACE Installation Instructions Before you begin, please note the following considerations: Safety First! Please use
More informationHall of Waters List of Historic Drawings
List of Historic Drawings The following represents the historic drawings of the PROJECT PWA PROJECT NUMBER JOB NUMBER SHEET NUMBER SHEET TITLE DATE NOTES 1935 Drawing Piping Layout at Tank Room for Mineral
More informationClass A Industrial Warehouse - 65,000 SF For Sale or Lease 240 N. Carolina Drive, El Paso Texas
240 N. Carolina Drive, El Paso Texas For Information, please contact: Adin A. Brown, SIOR, President Sonny Brown Associates, LLC (915) 584-5511 office (915) 549-5511 mobile adin@sonnybrown.com For more
More informationLetter of Transmittal
3710 QUINCY AVENUE OGDEN, UT 84403-1934 Ph : (801)627-1414 Letter of Transmittal To: GEN ARCHITECTS, INC. 11001 SW RIVERSIDE DRIVE PORTLAND, OR 97219 Ph: (503)243-7183 Fax: (503)243-7193 Subject: Submittal
More information