Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Size: px
Start display at page:

Download "Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues"

Transcription

1 Instructions XRD , Sami Suihkonen General issues Be very gentle when closing the doors Always use Cu attenuator when count rate exceeds c/s Do not over tighten optical modules or attach them misaligned (module edges should align with module holder edges) Make sure detector side cables cannot knock down other modules when moving Do not move the tube when the generator is on 1 Choose your setup Choose a setup and screw modules in place. X-ray reflectivity (XRR) o Thin amorphous or crystalline film (<200nm) thickness, density and roughness Grazing incidence XRD (GIXRD) o Very thin film XRD (<100 nm). o Assumes random orientation, i.e. not suitable for preferred orientation Powder XRD (PXRD) o XRD of powders and bulk polycrystalline samples. Suitable for preferred orientation High resolution XRD (HRXRD) o Single crystal measurements.

2 1.1 XRR and GIXRD setup Incident beam optics o Progressive divergence slit (PDS) set to fixed 1/32 Soller slit 0.04 rad Mask, 5-20 mm Ni-filter (blocks Kβ- and broadband background radiation) o X-ray mirror (in extended position) ½ divergence slit Cu 0.1 mm attenuator, Attenuation factor , Activate 400k c/s de-activate 200k c/s o Monocromator, none Diffracted beam optics o Anti scatter slit: none o Receiving slit: Parallel plate collimator Slit o Filter: none o Mask: none o Soller slit: 0.04 rad o Beam attenuator: none o Mirror: none o Detector: either [1] or [2] o Collimator: Coll. 0.18" o Monocromator: Diff. Beam Flat Graphite

3 1.2 PXRD setup Incident beam optics o Progressive divergence slit (PDS) set to fixed 1/32 with attachments: Ni-filter (blocks Kβ- and broadband background radiation) Soller slit Beam mask. Size 5, 10, 15 or 20, depending on required beam size Diffracted beam optics o Progressive anti scatter slit (PASS) set to fixed 1/32 with attachments: Cu 0.1 mm attenuator (if not present in incident beam side mirror) Soller slit (optional) Progressive receiving slit (PRS) set to 3 mm Diffracted beam monochromator PW3123 Detector (either [1] or [2])

4 1.3 HRXRD setup Incident beam optics o Divergence slit: none o Mask: none o X-ray mirror Cu (MRD) in extended position ½ divergence slit (not in program options) o Monochromator 4xGe220(Mirror) Manual Crossed slits 4x4mm is a good starting point o Attenuator: Cu 0.1 mm (no need to set in program options during alignment) o Filter: none o Soller slit: none Diffracted beam optics o Triple axis with two beam paths: Anti-scatter slit, Receiving slit, Filter, Mask, Soller slit, Collimator, Mirror, Beam attenuator: none Lower beam path: Monochromator: Triple axis, 3 bounce, Detector [2] Upper beam path: Monocromator: none, Detector [1]

5 2 Starting procedure Close doors Open water flow, first outlet, then inlet Turn machine on from POWER button o Machine will lock doors, turn on generator and initialize o Wait until it is ready (1 min) o Open software Data Collector and connect to the right configuration XRR and GIXRD: Instrument->Connect->Linefocus_Collimator PXRD: Instrument->Connect->Linefocus_PRS+PASS HRXRD: Instrument->Connect->Linefocus_Triple axis, lower beam path o Clear sample offsets "No" Check that the components listed in Incident beam optics and Diffracted beam optics match the fitted modules o Mirror position, extended or standard, must be specified correctly to avoid ~0.8 error in 2θ o Especially for XRR measurements the Cu 0.1 attenuator settings need to be correct: Incident Beam Optics/Beam attenuator/cu 0.1 mm manual Activate at pre-set intensity, new user default values are wrong, correct ones: Activate level c/s De-activate level c/s Attenuation needs to be , new user default value 20 causes problems! can be changed in Main screen/customize/beam Attenuators Tube breeding o Machine has not been used in less than 100 hrs, no breeding is needed o Machine has not been used in more than 100 hrs, choose Tools->Tube breeding->fast (15 min) o Normal tube breeding (40 min) is needed only when conditioning new tube for the first time. Set tube current and voltage in Instrument Settings->X-Ray Generator to 40 ma and 40kV

6 3 Alignment 3.1 Basic alignment Step needs to be done only once after changing modules or starting machine. Steps and need to be done after changing sample Align detector to incident beam Make sure the Cu 0.1 attenuator is in place, and its settings are correct (see 2. Starting procedure) Scan 2θ around 0; the peak intensity must be the true 0-position (beam goes direct into detector) o Measure -> Manual scan->scan axis=2θ o Scan range usually < 0.5 o Time per step=.05 o Choose step size to taste (e.g for XRR, GIXRD and PXRD, for HRXRD) o Set position to 0 Right click and choose Peak Mode to calculate peak position. Press Move To, the detector will move to position of max intensity Save the offset in Tools->Sample offsets o Sample offsets works so that you always type in the value of what the current position SHOULD be and then press OK o In this case, it should be 0

7 3.1.2 Adjust sample height Increase Z-value until ½ of the intensity is blocked by the sample There is no scan for this Change z-value at Positions->z No need to save offset Align sample parallel to the beam The sample will be slightly misaligned, i.e. ω=0 will not correspond to zero angle between sample surface and beam. There are two ways to do the alignment, both scan ω to find the maximum value Direct beam: Scan ω around 0

8 Works for all samples Slightly inaccurate Scan ω around 0; the peak intensity must be the true 0-position (sample parallel to beam) o Manual scan->scan axis= ω o Scan range usually < 3 o Time per step=.05 o Choose step size to taste, e.g o Save ω peak position in offsets as 0 o Adjust z again, if offset is large Totally reflected beam: Scan ω around mirror condition Works for smooth, straight, well reflecting samples Very accurate Scan ω around half of 2θ value, i.e. assume mirror condition. The peak intensity must correspond to the true value of ω= θ. o Manual scan->scan axis= ω o Set position, e.g. 2θ=0.4, ω= 0.2 o Scan range usually < 3 o Time per step=.05 o Choose step size to taste, e.g o Save ω peak position in offsets in this case as 0.2, i.e. half of 2θ value if another 2θ value is used o Adjust z again, if offset is large, but remember to set 2θ=0 and ω=0 The diffractometer and the sample are now aligned.

9 4 XRR measurements 4.1 Test measurement A quick ω-2θ scan to check that everything is ok: o make sure that Cu 0.1 attenuator is in place o Manual scan->scan axis= ω-2θ o Set centre position of the measurement e.g. ω= 0.6 o Scan range usually e.g 1 o Time per step=.05 o Choose step size to taste, e.g , 1 min scan should be sufficient o This will make a ω-2θ scan from 0.1 to 1.1, which should show a total reflection at around ω< 0.3 and several oscillations o You should be asked to remove the Cu 0.1 attenuator when detector counts fall below 2000, and insert the attenuator when the scan is finished 4.2 Full measurement Use measurement programs to measure and automatically save data Create program: File->New program o Absolute scan o Linefocus_collimator, continuous o Choose scan Axis ω-2θ for XRR o Choose step size and time per step according to preference o Close and it will ask you to save changes To measure, choose: Measure->Program->Your program->give the file an unique name 4.3 Data export The data may be inspected using the software X'Pert Graphics&Identify The data can be exported using the software X'Pert Organizer o Choose Database/Export/Scans and select the files you want to export o Select all files in the Export Scans window and choose Folder and select your folder in C:\Program Files\Phillips\X'Pert Software\Data o Check that Xnn file format is selected o Select again all files and choose export o Copy the exported files to shared folder E:SharedWin2kXP\your folder o You can now access the files in WinXP 4.4 Data analysis The exported scans can be analysed with XRR simulation software Software available from the main users Tips: o o The software is installed by unzipping the contents of the xrr.zip file to a folder. Software is started by running the xrr.jar file. The simulated layer structure can be modified in the Layer editor -tab. The default layer structure consists of a silicon substrate, native oxide and the thin film layer. Layer parameters can be modified by selecting the desired layer and clicking the Edit -button. The fit-check box selects the parameters for automatic fitting.

10 o o o The simulated reflection curve of the layer structure is shown in the Manual fit -tab. Measurement data in.x00 format is added to the software from File/Load measurement. Automatic fitting is done in the Automatic fit -tab. First load the layer structure from Import model. Export model returns the fitted values to the Layer editor -tab and manual fitting window. Default fitting parameters of the software can be used. Fitted reflectivity curves can be exported in.txt format after fitting from Data/Linear plot and File/Export. First column of the text file is the angle (θ in degrees), second the simulated data and third the measured data. Fitted layer parameters can be exported in.txt format from File/Export layers to text file.

11 5 XRD measurements 5.1 Align a specific reflection Use Positions->Unit cell->your unit cell to insert Miller indices. The program will calculate angular positions based on unit cell parameters. Press OK If using HRXRD, switch to Upper beampath o Large acceptance angle will help in alignment Use manual scans to maximize intensity and bring the sample to the Bragg condition o rough ω-scan o ~7 φ scan, can in theory be omitted for symmetric reflection o ~7 ψ scan o More accurate ω scan If using HRXRD, switch to Lower beampath o Accurate 2θ scan 5.2 Full measurement Use measurement programs to measure and automatically save data Create program: File->Program->New program o Choose scan Axis o Choose step size and time per step according to preference o Close and it will ask you to save changes To measure, choose: Measure->Program->Your program->give the file an unique name 5.3 Data export The data may be inspected using the software X'Pert Graphics&Identify The data can be exported using the software X'Pert Organizer o Choose Database/Export/Scans and select the files you want to export o Select all files in the Export Scans window and choose Folder and select your folder in C:\Program Files\Phillips\X'Pert Software\Data o Check that Xnn file format is selected o Select again all files and choose Ok o Copy the exported files to shared folder E:SharedWin2kXP\your folder o You can now access the files in WinXP 5.4 Data analysis The exported scans can be analysed with XRD simulation software Software available from the main users

12 6 Shut-down Set generator current and voltage in Instrument Settings->X-Ray Generator to 15 kv and 5 ma Let tube cool down for a few minutes Insert Cu 0.1 attenuator Set diffractometer to zero position and remove the sample Switch off the generator Instrument->Disconnect Turn off the cooling water System stand by 7 Problems Diffractometer will not start, cannot connect to instrument o Doors were not locked and the instrument could not initialize o Turn off XRD-machine, close doors properly and restart No signal o Wrong detector

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: ) University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: 2012.10.17) The following instructions

More information

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: ) University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: 2012.10.17) The following

More information

Basic P-XRD instructions for Operating the Instrument

Basic P-XRD instructions for Operating the Instrument Basic P-XRD instructions for Operating the Instrument Instrument Parts Incident Beam Optics (left arm) 1) X-ray source (Cu) i. Rest settings: 45 kv, 20mA ii. Run settings: 45 kv, 40mA 2) Monochromator

More information

Lesson 2 Diffractometers

Lesson 2 Diffractometers Lesson 2 Diffractometers Nicola Döbelin RMS Foundation, Bettlach, Switzerland January 14 16, 2015, Bern, Switzerland Repetition: Generation of X-rays / Diffraction SEM: BSE detector, BSED / SAED detector

More information

General Measurement (BB) Part

General Measurement (BB) Part General Measurement (BB) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Setting measurement origin and oscillation/spin conditions... 7 General Measurement (BB)

More information

Using the Open Eularian Cradle (OEC)

Using the Open Eularian Cradle (OEC) Using the Open Eularian Cradle (OEC) with the High-Speed Bragg-Brentano Optics on the PANalytical X Pert Pro MPD Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT Speakman@mit.edu

More information

Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector

Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector Abridged SOP for Manually Aligning a Sample and Collecting Data using XRD Commander Scott A Speakman, Ph.D. MIT Center for

More information

Precise Theta/2-Theta Measurement (PB/PSA) Part

Precise Theta/2-Theta Measurement (PB/PSA) Part Precise Theta/2-Theta Measurement (PB/PSA) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Customizing scan conditions and slit conditions... 6 2. Measurement

More information

Residual Stress Measurement Part

Residual Stress Measurement Part Residual Stress Measurement Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Customizing scan conditions and slit conditions... 8 2. Measurement sequence...19 Residual

More information

Bruker D8 HRXRD. Collecting Reciprocal Space Maps using the LynxEye Position Sensitive Detector

Bruker D8 HRXRD. Collecting Reciprocal Space Maps using the LynxEye Position Sensitive Detector Bruker D8 HRXRD Collecting Reciprocal Space Maps using the LynxEye Position Sensitive Detector Scott A Speakman, Ph.D. MIT Center for Materials Science and Engineering For help in the X-ray Lab, contact

More information

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection) Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection) For any questions regarding the X-ray facility, contact: Pascal Schouwink pascal.schouwink@epfl.ch

More information

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 332 ABSTRACT X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION Bob B. He and Uwe Preckwinkel Bruker

More information

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016 Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016 1 SAFETY. For radiation safety materials refer to http://www.ehs.wisc.edu/raddevices.htm. There

More information

Experiment #12 X-Ray Diffraction Laboratory

Experiment #12 X-Ray Diffraction Laboratory Physics 360/460 Experiment #12 X-Ray Diffraction Laboratory Introduction: To determine crystal lattice spacings, as well as identify unknown substances, a x-ray diffractometer is used to replace the traditional

More information

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror Stephen B. Robie scintag, Inc. 10040 Bubb Road Cupertino, CA 95014 Abstract Corundum

More information

Standard Operating Procedure for STOE STADI MP (IMSERC)

Standard Operating Procedure for STOE STADI MP (IMSERC) Follow the general steps when computer has been restarted or last user has accidentally logged off. Please remember to: 1. Leave lab tables clean and tools/accessories organized 2. Return any unused masks

More information

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P Solid-state physics Properties of crystals X-ray structural analysis LEYBOLD Physics Leaflets Bragg reflection: determining the lattice constants of monocrystals P7.1.2.1 Objects of the experiment Investigating

More information

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015) ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015) Purpose The purpose of the lab is (i) To measure the spot size and profile of the He-Ne laser beam and a laser pointer laser beam. (ii) To create a beam expander

More information

General Measurement (CALSA) Part

General Measurement (CALSA) Part General Measurement (CALSA) Part Contests Contests 1. How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Setting measurement origin and oscillation/spin conditions... 7 General Measurement

More information

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT OBJECTIVES To determine the limit wavelength min of the bremsstrahlung continuum as a function of the high voltage U of the x-ray tube. To confirm

More information

TOWARDS FAST RECIPROCAL SPACE MAPPING

TOWARDS FAST RECIPROCAL SPACE MAPPING Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 165 ABSTRACT TOWARDS FAST RECIPROCAL SPACE MAPPING J.F. Woitok and A. Kharchenko PANalytical B.V.,

More information

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics Atomic and nuclear physics LD Physics X-ray physics Structure of x-ray spectra Leaflets P6.3.6.3 Fine structure of the characteristic x-radiation of an iron anode Objects of the experiment g Investigating

More information

Atomic and nuclear physics

Atomic and nuclear physics Atomic and nuclear physics X-ray physics Physics of the atomic shell LEYBOLD Physics Leaflets Investigating the energy spectrum of an x-ray tube as a function of the high voltage and the emission current

More information

Tutorial Zemax 9: Physical optical modelling I

Tutorial Zemax 9: Physical optical modelling I Tutorial Zemax 9: Physical optical modelling I 2012-11-04 9 Physical optical modelling I 1 9.1 Gaussian Beams... 1 9.2 Physical Beam Propagation... 3 9.3 Polarization... 7 9.4 Polarization II... 11 9 Physical

More information

SUPPORTING INFORMATION

SUPPORTING INFORMATION SUPPORTING INFORMATION Surface-Guided CsPbBr 3 Perovskite Nanowires on Flat and Faceted Sapphire with Size-Dependent Photoluminescence and Fast Photoconductive Response Eitan Oksenberg, Ella Sanders, Ronit

More information

Powder X-Ray Diffraction Alignment Procedure

Powder X-Ray Diffraction Alignment Procedure FLORIDA STATE UNIVERSITY Powder X-Ray Diffraction Alignment Procedure Procedure for aligning Rigaku Ultima III w/ Mercury CCD using Scintillation Detector for calibration 2013-14 Thayumanasamy Somasundaram

More information

Rigaku Cr-Source RU300 Rotating Anode X-Ray Generator 185mm Radius Diffractometer

Rigaku Cr-Source RU300 Rotating Anode X-Ray Generator 185mm Radius Diffractometer CENTER FOR MATERIALS SCIENCE & ENGINEERING at MIT X-RAY DIFFRACTION SHARED EXPERIMENTAL FACILITY STANDARD OPERATING PROCEDURES for the Rigaku Cr-Source RU300 Rotating Anode X-Ray Generator 185mm Radius

More information

Howie's Laser Collimator Instructions:

Howie's Laser Collimator Instructions: Howie's Laser Collimator Instructions: WARNING: AVOID DIRECT OR MIRROR REFLECTED EYE EXPOSURE TO LASER BEAM The laser collimator is a tool that enables precise adjustment of the alignment of telescope

More information

Dinnebier & Billinge, TA+PXRD course - Part 1, The Equipment

Dinnebier & Billinge, TA+PXRD course - Part 1, The Equipment Powder X-ray Diffraction (PXRD) in short MATR362 - Workshop on X-ray diffraction and thermoanalytical methods (5 cr) Prof. Markku Leskelä / Mikko Heikkilä Dinnebier & Billinge, 1 2 Aim of these lectures

More information

Supplementary Information

Supplementary Information Supplementary Information Supplementary Figure 1. Modal simulation and frequency response of a high- frequency (75- khz) MEMS. a, Modal frequency of the device was simulated using Coventorware and shows

More information

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation Miniflex Rigaku/ Miniflex X-ray Diffractometer System Rigaku Corporation Rigaku/ Miniflex X-ray Diffractometer System 1. Introduction Rigaku s general purpose X-ray diffractometer systems are broadly classified

More information

Alignment of the camera

Alignment of the camera Related topics Detector Alignment, Rotation axis, tilt, Principle Alignment of the detector and the rotation stage is very important to get optimal quality images of a CT scan. In this experiment, the

More information

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES OBJECTIVES In this lab, firstly you will learn to couple semiconductor sources, i.e., lightemitting diodes (LED's), to optical fibers. The coupling

More information

Using the R-Axis Spider to run thin films

Using the R-Axis Spider to run thin films Using the R-Axis Spider to run thin films In addition to loose powder samples, it is possible to run thin film samples on the R-Axis Spider. Use the zero background plate holder for your thin film sample.

More information

Cr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70%

Cr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70% PARALLEL BEAM X-RAY OPTICS y Mirror length L Θ = f(x) b p/2 λ = 2d eff (x) sin Θ(x) eff x m Parallel beam width b=f(p,λ,l,,l,x m ) x Fabrication of high precision 6 mm parallel beam optics both on prefigured

More information

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress AutoMATE II Micro-area X-ray stress measurement system Highly accurate micro area residual stress The accuracy of an R&D diffractom dedicated residua In the past, if you wanted to make highly accurate

More information

Properties of Structured Light

Properties of Structured Light Properties of Structured Light Gaussian Beams Structured light sources using lasers as the illumination source are governed by theories of Gaussian beams. Unlike incoherent sources, coherent laser sources

More information

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information The Rigaku Journal Vol. 15/ number 2/ 1998 Product Information X-ray Single Crystal Structure Analysis System R-AXIS RAPID 1. Introduction X-ray single crystal structure analysis is known as the easiest

More information

Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta

Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta 1 Introducing Rigaku Since its inception in Japan in 1951, Rigaku has been at the forefront of analytical and industrial instrumentation

More information

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE 09DJ00 CHRIS BUXEY (TECHNICIAN) X2715 C.BUXEY@SURREY.AC.UK V5.0 OCTOBER 2008 RENISHAW MICRORAMAN STANDARD OPERATING PROCEDURE 1.0 Foreword Chris Buxey:

More information

SPRAY DROPLET SIZE MEASUREMENT

SPRAY DROPLET SIZE MEASUREMENT SPRAY DROPLET SIZE MEASUREMENT In this study, the PDA was used to characterize diesel and different blends of palm biofuel spray. The PDA is state of the art apparatus that needs no calibration. It is

More information

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry LECTURE 10 Dr. Teresa D. Golden University of North Texas Department of Chemistry Components for the source include: -Line voltage supply -high-voltage generator -x-ray tube X-ray source requires -high

More information

Radial Polarization Converter With LC Driver USER MANUAL

Radial Polarization Converter With LC Driver USER MANUAL ARCoptix Radial Polarization Converter With LC Driver USER MANUAL Arcoptix S.A Ch. Trois-portes 18 2000 Neuchâtel Switzerland Mail: info@arcoptix.com Tel: ++41 32 731 04 66 Principle of the radial polarization

More information

Lab 12 Microwave Optics.

Lab 12 Microwave Optics. b Lab 12 Microwave Optics. CAUTION: The output power of the microwave transmitter is well below standard safety levels. Nevertheless, do not look directly into the microwave horn at close range when the

More information

The 34th International Physics Olympiad

The 34th International Physics Olympiad The 34th International Physics Olympiad Taipei, Taiwan Experimental Competition Wednesday, August 6, 2003 Time Available : 5 hours Please Read This First: 1. Use only the pen provided. 2. Use only the

More information

Recording EPR Spectra using ER 4102ST Resonator

Recording EPR Spectra using ER 4102ST Resonator Recording EPR Spectra using ER 4102ST Resonator This protocol gives step-by-step instructions for recording an EPR spectrum using the high sensitivity Bruker SHQE cavity (assuming the SHQE is already in

More information

RENISHAW INVIA RAMAN SPECTROMETER

RENISHAW INVIA RAMAN SPECTROMETER STANDARD OPERATING PROCEDURE: RENISHAW INVIA RAMAN SPECTROMETER Purpose of this Instrument: The Renishaw invia Raman Spectrometer is an instrument used to analyze the Raman scattered light from samples

More information

DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE

DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE THE RIGAKU JOURNAL VOL. 7 / NO. 2 / 1990 Technical Note DIFFRACTION DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE ATSUSHI SHIBATA R&D Division, Rigaku Corporation 1. Introduction

More information

Will contain image distance after raytrace Will contain image height after raytrace

Will contain image distance after raytrace Will contain image height after raytrace Name: LASR 51 Final Exam May 29, 2002 Answer all questions. Module numbers are for guidance, some material is from class handouts. Exam ends at 8:20 pm. Ynu Raytracing The first questions refer to the

More information

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information THE RIGAKU JOURNAL VOL. 11 I NO.2 I 1994 Product Information X-RAY MICRODIFFRACTOMETER PSPC/MDG 2000 1. Introduction The analysis of X-ray diffraction patterns is well known as an effective means of obtaining

More information

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

ADVANCED OPTICS LAB -ECEN Basic Skills Lab ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 Revised KW 1/15/06, 1/8/10 Revised CC and RZ 01/17/14 The goal of this lab is to provide you with practice

More information

Instructions for Tecnai a brief start up manual

Instructions for Tecnai a brief start up manual Instructions for Tecnai a brief start up manual Version 3.0, 8.12.2015 Manual of Tecnai 12 transmission electron microscope located at Aalto University's Nanomicroscopy Center. More information of Nanomicroscopy

More information

Data Collection with. VÅNTEC-2000 Detector

Data Collection with. VÅNTEC-2000 Detector Data Collection with IµS Source and VÅNTEC-2000 Detector D8 System Configuration for Reflection Microfocus Source IµS Optics with Housing 2D Detector (VÅNTEC-2000) DHS 900 Heating Stage Sample Stage Bruker

More information

Excel Tool: Plots of Data Sets

Excel Tool: Plots of Data Sets Excel Tool: Plots of Data Sets Excel makes it very easy for the scientist to visualize a data set. In this assignment, we learn how to produce various plots of data sets. Open a new Excel workbook, and

More information

Operating Procedures for MICROCT1 Nikon XTH 225 ST

Operating Procedures for MICROCT1 Nikon XTH 225 ST Operating Procedures for MICROCT1 Nikon XTH 225 ST Ensuring System is Ready (go through to ensure all windows and tasks below have been completed either by you or someone else prior to mounting and scanning

More information

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0 Instruction manual for T3DS software Release 4.0 Table of contents 0. Setup... 3 1. Start-up... 5 2. Input parameters and delay line control... 6 3. Slow scan measurement... 8 4. Fast scan measurement...

More information

Recording EPR spectra using the Loop Gap Resonator (LGR)

Recording EPR spectra using the Loop Gap Resonator (LGR) Recording EPR spectra using the Loop Gap Resonator (LGR) This protocol gives step-by-step instructions for recording EPR spectra of spin labeled proteins (Nitroxide label like MTSSL) using the LGR assuming

More information

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right Quick Guide to Operating FEI Titan Themis G2 200 (S)TEM: TEM mode Susheng Tan Nanoscale Fabrication and Characterization Facility, University of Pittsburgh Office: M104/B01 Benedum Hall, 412-383-5978,

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

CNC Turning Training CNC MILLING / ROUTING TRAINING GUIDE. Page 1

CNC Turning Training CNC MILLING / ROUTING TRAINING GUIDE.  Page 1 CNC Turning Training www.denford.co.uk Page 1 Table of contents Introduction... 3 Start the VR Turning Software... 3 Configure the software for the machine... 4 Load your CNC file... 5 Configure the tooling...

More information

Quick Start MMRC Nicolet 6700 Revised 10/24/2018

Quick Start MMRC Nicolet 6700 Revised 10/24/2018 Do Not Remove Quick Start MMRC Nicolet 6700 Revised 10/24/2018 1. Fill out the logbook before you begin. 2. Before you start the Nicolet should be on with purge gas flowing. 3. Check that the purge gas

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS B SCIENTIFIC PHYSICS Cavendish Torsion Balance 007 Operating instructions 06/8 ALF. Description The Cavendish torsion balance is for demonstrating the gravitational attraction between two masses and determining

More information

The Wave Nature of Light

The Wave Nature of Light The Wave Nature of Light Physics 102 Lecture 7 4 April 2002 Pick up Grating & Foil & Pin 4 Apr 2002 Physics 102 Lecture 7 1 Light acts like a wave! Last week we saw that light travels from place to place

More information

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4 Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4 S.V. Roth, R. Döhrmann, M. Dommach, I. Kröger, T. Schubert, R. Gehrke Definition of the upgrade The wiggler beamline BW4 is dedicated to

More information

Excel Lab 2: Plots of Data Sets

Excel Lab 2: Plots of Data Sets Excel Lab 2: Plots of Data Sets Excel makes it very easy for the scientist to visualize a data set. In this assignment, we learn how to produce various plots of data sets. Open a new Excel workbook, and

More information

USING EFI DOT FILM ON EPSON STYLUS PRO 4000 AND X600/X800 SERIES PRINTERS

USING EFI DOT FILM ON EPSON STYLUS PRO 4000 AND X600/X800 SERIES PRINTERS 1 USING EFI DOT FILM ON EPSON STYLUS PRO 4000 AND X600/X800 SERIES EFI Dot Film is a transparent media that is often used to output grayscale separations for offset and silk-screen printing. This document

More information

Supplementary User Manual for BSWA Impedance Tube Measurement Systems

Supplementary User Manual for BSWA Impedance Tube Measurement Systems Supplementary User Manual for BSWA Impedance Tube Measurement Systems 1 P age Contents Software Installation... 3 Absorption Measurements -- ASTM Method... 4 Hardware Set-Up... 4 Sound card Settings...

More information

Service Manual for XLE/XLT Series Laser Engravers

Service Manual for XLE/XLT Series Laser Engravers Service Manual for XLE/XLT Series Laser Engravers Table of Contents Maintenance...1 Beam alignment...3 Auto focus alignment...8 Bridge alignment...10 Electronics panel replacement...11 X motor change...12

More information

Film Holder Accessories

Film Holder Accessories Page 1 of 9 Film Holder Accessories For Cary 1/3/4/5/100/300/400/500/500i/4000/5000/6000i/Deep UV Part numbers: Cary 100/300-0010048500; Cary 400/500/500i/4000/5000/6000i - 0210125400 Contents This document

More information

State-of-the-art thin film X-ray optics for synchrotrons and FEL sources. Frank Hertlein Incoatec GmbH Geesthacht, Germany

State-of-the-art thin film X-ray optics for synchrotrons and FEL sources. Frank Hertlein Incoatec GmbH Geesthacht, Germany State-of-the-art thin film X-ray optics for synchrotrons and FEL sources Frank Hertlein Incoatec GmbH Geesthacht, Germany Incoatec: Innovative Coating Technologies Incoatec is founded with Bruker AXS in

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Nanosurf Atomic Force Microscopy Operation Facility NCCRD Nanotechnology Center for Collaborative Research and Development Department of Chemistry and Engineering Physics The

More information

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE Exercise 4 Angle Tracking Techniques EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the principles of the following angle tracking techniques: lobe switching, conical

More information

How to align your laser for two-photon imaging

How to align your laser for two-photon imaging How to align your laser for two-photon imaging Two-photon microscopy uses a laser to excite fluorescent molecules (fluorophores) within a sample through emitting short pulses of light at high power. This

More information

Instructions LASNIX Polarization Sensors Models 601, 605, option H

Instructions LASNIX Polarization Sensors Models 601, 605, option H Instructions LASNIX Polarization Sensors Models 601, 605, option H 1. HANDLING. LASNIX polarization sensors operate on the principle of a rotating linear polarizer. The polarizer element is a very thin

More information

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 346 DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY

More information

IBIL setup operation manual for SynerJY software version

IBIL setup operation manual for SynerJY software version IBIL setup operation manual for SynerJY software version 1.8.5.0 Manual version 1.0, 31/10/2008 Author: Carlos Marques Equipment Managers: Carlos Marques, +351219946084, cmarques@itn.pt Luís Alves, +351219946112,

More information

Eric B. Burgh University of Wisconsin. 1. Scope

Eric B. Burgh University of Wisconsin. 1. Scope Southern African Large Telescope Prime Focus Imaging Spectrograph Optical Integration and Testing Plan Document Number: SALT-3160BP0001 Revision 5.0 2007 July 3 Eric B. Burgh University of Wisconsin 1.

More information

Stitching MetroPro Application

Stitching MetroPro Application OMP-0375F Stitching MetroPro Application Stitch.app This booklet is a quick reference; it assumes that you are familiar with MetroPro and the instrument. Information on MetroPro is provided in Getting

More information

This lecture contains four sections as reading information.

This lecture contains four sections as reading information. Sample Preparation: The Backloading Technique This lecture contains four sections as reading information. Basic XRD Course 1 Sample Preparation: The Backloading Technique Basic XRD Course 2 Sample Preparation:

More information

Model SU3500 Scanning Electron Microscope

Model SU3500 Scanning Electron Microscope Model SU3500 Scanning Electron Microscope Modified and Parts taken from Hitachi Easy Operation Guide. Before using the Model SU3500 SEM, be sure to read the [GENERAL SAFETY GUIDELINES] in the instruction

More information

OPTICAL BENCH - simple type

OPTICAL BENCH - simple type GENERAL DESCRIPTION: OPTICAL BENCH - simple type Cat: HL2240-001 Complete with Hodson Light Box. Cat: HL2241-001 Not including Hodson Light Box The IEC Optical Bench system is designed to be used with

More information

RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS

RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 166 RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS ABSTRACT Scott T. Misture NYS College

More information

PAD Correlator Computer

PAD Correlator Computer ALIGNMENT OF CONVENTIONAL ROATING ARM INSTRUMENT GENERAL PRINCIPLES The most important thing in aligning the instrument is ensuring that the beam GOES OVER THE CENTER OF THE TABLE. The particular direction

More information

Installing the detector filter assembly (G )

Installing the detector filter assembly (G ) s1 Installing the detector filter assembly (G1600-62700) The detector filter transmits light of a defined wavelength range. Figure 1 shows a typical transmission spectrum. Maximum transmission is between

More information

Part 1: Standing Waves - Measuring Wavelengths

Part 1: Standing Waves - Measuring Wavelengths Experiment 7 The Microwave experiment Aim: This experiment uses microwaves in order to demonstrate the formation of standing waves, verifying the wavelength λ of the microwaves as well as diffraction from

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

PHY 431 Homework Set #5 Due Nov. 20 at the start of class PHY 431 Homework Set #5 Due Nov. 0 at the start of class 1) Newton s rings (10%) The radius of curvature of the convex surface of a plano-convex lens is 30 cm. The lens is placed with its convex side down

More information

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004 Lithography 3 rd lecture: introduction Prof. Yosi Shacham-Diamand Fall 2004 1 List of content Fundamental principles Characteristics parameters Exposure systems 2 Fundamental principles Aerial Image Exposure

More information

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop 1. Log in usage using the SMIF web site 2. Turn power

More information

BL39XU Magnetic Materials

BL39XU Magnetic Materials BL39XU Magnetic Materials BL39XU is an undulator beamline that is dedicated to hard X-ray spectroscopy and diffractometry requiring control of the X-ray polarization state. The major applications of the

More information

Vinyl Cutter Instruction Manual

Vinyl Cutter Instruction Manual Vinyl Cutter Instruction Manual 1 Product Inventory Inventory Here is a list of items you will receive with your vinyl cutter: Product components (Fig.1-4): 1x Cutter head unit complete with motor, plastic

More information

Exp. No. 13 Measuring the runtime of light in the fiber

Exp. No. 13 Measuring the runtime of light in the fiber Exp. No. 13 Measuring the runtime of light in the fiber Aim of Experiment The aim of experiment is measuring the runtime of light in optical fiber with length of 1 km and the refractive index of optical

More information

Who is GBC Scientific Equipment?

Who is GBC Scientific Equipment? Who is GBC Scientific Equipment? GBC Scientific Equipment Pty Ltd commenced operations in 1978. GBC designs, manufactures and markets a range of scientific instruments comprising Atomic Absorption spectrometers

More information

Ornamental Pro 2010 Component Drawing Manual

Ornamental Pro 2010 Component Drawing Manual Ornamental Pro 2010 Component Drawing Manual Introduction This manual explains the methods for creating your own components for the component library. Component mode is for advanced users only. You must

More information

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack).

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack). FEI Tecnai F20 S/TEM: imaging in TEM mode Nicholas G. Rudawski ngr@ufl.edu (805) 252-4916 (352) 392-3077 Last updated: 01/21/18 1. Filling the cold trap (if needed) 1.1. Prior to use, the cold trap needs

More information

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers QE65000 Spectrometer Scientific-Grade Spectroscopy in a Small Footprint QE65000 The QE65000 Spectrometer is the most sensitive spectrometer we ve developed. Its Hamamatsu FFT-CCD detector provides 90%

More information

Photolithography II ( Part 2 )

Photolithography II ( Part 2 ) 1 Photolithography II ( Part 2 ) Chapter 14 : Semiconductor Manufacturing Technology by M. Quirk & J. Serda Saroj Kumar Patra, Department of Electronics and Telecommunication, Norwegian University of Science

More information

Automated Double Aperture Accessory

Automated Double Aperture Accessory For the Cary 1, 3, 100, 300, 4, 5, 400, 500, 500i, 4000, 5000, 6000i, Deep UV Installation Category II Pollution Degree 2 Equipment Class I Table of Contents Introduction Theory Operation Installation

More information

Illumination of Linear Variable Filters with a laser beam

Illumination of Linear Variable Filters with a laser beam Illumination of Linear Variable Filters with a laser beam The intensity distribution in the laser beam from a super continuum light-source is assumed to be purely Gaussian. The spot size on the linear

More information

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza Experiment C & D: Course: FY1 The Pulsed Laser Done by: Wael Al-Assadi Mangwiza 8/1/ Wael Al Assadi Mangwiza Experiment C & D : Introduction: Course: FY1 Rev. 35. Page: of 16 1// In this experiment we

More information