GENERAL GENERAL NOTES & STATEMENT OF ESTIMATED QUANTITIES BRT-G-8 SHEET OF C.P S.A.P SHEET NAME:

Size: px
Start display at page:

Download "GENERAL GENERAL NOTES & STATEMENT OF ESTIMATED QUANTITIES BRT-G-8 SHEET OF C.P S.A.P SHEET NAME:"

Transcription

1 NO DATE BY REVISION / SUBMITTAL APP GENERAL NOTES & STATEMENT OF ESTIMATED QUANTITIES GENERAL BRT-G-8

2

3

4

5 NO DATE BY REVISION / SUBMITTAL APP STRUCTURAL NOTES STRUCTURAL SAP BRT-D-5

6 NO DATE BY REVISION / SUBMITTAL APP SHELTER BASE PLANS STRUCTURAL SAP BRT-D-6

7 NO DATE BY REVISION / SUBMITTAL APP SHELTER ELEVATION STRUCTURAL SAP BRT-D-7

8 NO DATE BY REVISION / SUBMITTAL APP SLAB SECTION AND DETAILS STRUCTURAL SAP BRT-D-8

9 NO DATE BY REVISION / SUBMITTAL APP PYLON FOOTING DETAILS STRUCTURAL SAP BRT-D-9

10 ONE LINE OR CONTROL DIAGRAM FRAME TRIP 480V TO 20/208Y 30 KVA K-* A TO 5 V TO 20 PLAN CB F P 2 LP LOW VOLTAGE AIR OR MOLDED CASE CIRCUIT BREAKER, 3 POLE UNLESS OTHERWISE NOTED COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC MOTOR STARTER, FULL VOLTAGE NON-REVERSING UNLESS OTHERWISE NOTED: FVR - FULL VOLTAGE REVERSING RVNR - REDUCED VOLTAGE NON-REVERSING 2SW - TWO SPEED, ONE WINDING 2S2W - TWO SPEED, TWO WINDING NON-FUSIBLE DISCONNECT SWITCH, 600 VOLT, 3 POLE AMPERE RATING NOTED IF OTHER THAN 30A FUSIBLE DISCONNECT SWITCH, 600 VOLT, 3 POLE, AMPERE RATING AND FUSE SIZE AS NOTED AMPERE RATING NOTED IF OTHER THAN 30A FUSE RATING EXAMPLE 5 MANUAL MOTOR STARTER WITH THERMAL OVERLOAD HEATER "P" INDICATES WITH PILOT LIGHT "2" INDICATES TWO POLE TRANSFORMER, RATINGS AND CONNECTIONS AS NOTED UNLESS OTHERWISE NOTED ON THE SINGLE LINE DIAGRAMS ALL DRY TYPE TRANSFORMERS SERVICING ADMINISTRATIVE AND LABORATORY SPACES SHALL HAVE A K FACTOR OF 3 ALL OTHER DRY TYPE TRANSFORMERS SHALL HAVE A K-4 RATING ISOLATION TRANSFORMERS SHALL HAVE A K-20 RATING CURRENT TRANSFORMER QUANTITY A = PRIMARY AMPERES POTENTIAL TRANSFORMER QUANTITY V = PRIMARY VOLTAGE STRIP LIGHT WALL MOUNTED LIGHT EXPOSED RACEWAY DESCRIPTION CONCEALED HOMERUN TO LP CONCEALED RACEWAY SPECIAL CAPACITOR SC - SURGE CAPACITOR PF - POWER FACTOR CORRECTION CAPACITOR PUSHBUTTON, MOMENTARY CONTACT, SPRING RETURN, NORMALLY CLOSED PUSHBUTTON, MOMENTARY CONTACT, SPRING RETURN, NORMALLY OPEN ONE LINE OR CONTROL DIAGRAM DM OR LA 30A CR TD PTT PLAN TS OR T OR HH CCTV DESCRIPTION CONDUCTORS ELECTRICALLY CONNECTED DAMPER MOTOR PILOT LIGHT, COLOR AS NOTED R - RED G - GREEN B - BLUE W - WHITE A - AMBER PILOT LIGHT, PUSH-TO-TEST TYPE, COLOR AS NOTED ABOVE LIGHTNING ARRESTER GROUND OR GROUND ROD FUSE, AMPERE RATING AS NOTED HEAT TRACE CABLE CONTACT, NORMALLY OPEN (NO) CONTACT, NORMALLY CLOSED (NC) CONTROL RELAY COIL, NUMBER AS INDICATED TIME DELAY RELAY RANGE AS NOTED SETPOINT AS NOTED TDE-TIME DELAY AFTER ENERGIZATION-ON DELAY TDD-TIME DELAY AFTER DE-ENERGIZATION-OFF DELAY NOTC-NORMALLY OPEN, TIMED CLOSING WHEN ENERGIZED NCTO-NORMALLY CLOSED, TIMED OPENING WHEN ENERGIZED NOTO-NORMALLY OPEN, TIMED OPENING WHEN DE-ENERGIZED NCTC-NORMALLY CLOSED, TIMED CLOSING WHEN DE-ENERGIZED TEMPERATURE SWITCH OR THERMOSTAT NORMALLY OPEN, CLOSES ON RISING TEMPERATURE NORMALLY OPEN, CLOSES ON DROPPING TEMP NORMALLY CLOSED, OPENS ON RISING TEMPERATURE NORMALLY CLOSED, OPENS ON DROPPING TEMP INDICATES LIMITS OF EQUIPMENT OR WIRING ENCLOSURE HAND HOLE CLOSED CIRCUIT TV CAMERA ELECTRICAL ABBREVIATIONS AC ALTERNATING CURRENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE A,AMP AMPERE AUTO AUTOMATIC AUX AUXILIARY AWG AMERICAN WIRE GAUGE C CONDUIT CAR COUNCIL AUTHORIZED REPRESENTATIVE CB CIRCUIT BREAKER CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CR CONTROL RELAY CS CONTROL SWITCH CT CURRENT TRANSFORMER CU COPPER DC DIRECT CURRENT DI DOOR INTERLOCK DN DOWN (E) EXISTING EC EMPTY CONDUIT ELEC ELECTRICAL ELEV ELEVATION EM EMERGENCY ETEL EMERGENCY TELEPHONE FBO FURNISHED BY OTHERS FCV FARE CARD VALIDATOR FDP FIBER DISTRIBUTION PANEL FO FIBER OPTIC (F) FUTURE FU FUSE GEC GROUNDING ELECTRODE CONDUCTOR G,GRD GROUND GF GROUND FAULT INTERRUPTER GRS GALVANIZED RIGID STEEL HH HANDHOLE HPB HEATER PUSH BUTTON HT HEIGHT HTR HEATER HZ HERTZ INST INSTANTANEOUS JCT JUNCTION BOX LA LIGHTNING ARRESTER LGT LIGHT LP LIGHTING PANEL MFR MANUFACTURER MH MANHOLE MMFO MULTI-MODE FIBER OPTIC MTG MOUNTING MTD MOUNTED NC NORMALLY CLOSED NO NORMALLY OPEN OR NUMBER NOM NOMINAL NTS NOT TO SCALE NVR NETWORK VIDEO RECORDER OL OVERLOAD PB PUSHBUTTON PH PHASE P,POL POLE PR PAIR PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE QTY QUANTITY REC RECEPTACLE RTS SC SCC SEC SH SMFO SN SS SVV SW TC TEL TO TVM TVSS TW TYP UG V W WP XFMR NOTES ELEC ABBREVIATIONS CONT REAL TIME SIGNAGE SURGE CAPACITOR COMMUNICATION CABINET ELECTRICAL CABINET SHIELDED OR SHEET SINGLE MODE FIBER OPTIC SOLID NEUTRAL STAINLESS STEEL STORED VALUE VALIDATOR SWITCH TIME DELAY ON CLOSING TELEPHONE TIME DELAY ON OPENING TICKET VENDING MACHINE TRANSIENT VOLTAGE SURGE SUPPRESSOR TWISTED TYPICAL UNDERGROUND VOLTS WIRE WEATHERPROOF TRANSFORMER HOMERUNS SHOWN CONCEALED SHALL BE INDICATIVE OF ENTIRE CIRCUIT INSTALLATION THE SAME SHALL APPLY FOR HOME- RUNS SHOWN EXPOSED REFER TO SPECIFICATIONS FOR MATERIALS AND INSTALLATION REQUIREMENTS 2 CONDUIT AND WIRE (NOT SHOWN) FOR FIXTURES, SWITCHES AND/OR RECEPTACLES SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AND SHALL BE: 2 " (MIN) CONDUIT RUN 22 EXPOSED IN UNFINISHED AREAS 23 CONCEALED ABOVE HUNG CEILINGS AND IN WALLS IN FINISHED AREAS 24 NO 2 COPPER (MIN) TYPE "THWN/THHN" NO OF WIRES REQUIRED 3 THE WIRING DIAGRAMS, QUANTITY AND SIZE OF WIRES AND CONDUIT REPRESENT A SUGGESTED ARRANGEMENT BASED UPON SELECTED STANDARD COMPONENTS OF ELECTRICAL EQUIPMENT MODIFICATIONS ACCEPTABLE TO THE CAR MAY BE MADE BY THE CONTRACTOR TO ACCOMODATE EQUIPMENT ACTUALLY PURCHASED THE BASIC SEQUENCE AND METHOD OF CONTROL MUST BE MAINTAINED AS INDICATED ON THE DRAWINGS AND/OR SPECIFICATIONS CONDUCTORS OR CONDUITS CROSSING PATHS BUT NOT CONNECTED FIBER OPTIC CABLE NO DATE BY REVISION / SUBMITTAL APP OVERALL ELECTRICAL SYMBOLS & ABBREVIATIONS BRT-D-20 SHEET OF

11 NO DATE BY REVISION / SUBMITTAL APP SITE & PAVING PLAN 46TH STREET & DIRECTION EASTBOUND 02-EB-

12 NO DATE BY REVISION / SUBMITTAL APP 46TH STREET & URBAN DESIGN PLAN 02-EB-2 DIRECTION EASTBOUND SHEET OF

13 NO DATE BY REVISION / SUBMITTAL APP SITE & PAVING PLAN 46TH STREET & DIRECTION WESTBOUND 02-WB-

14 NO DATE BY REVISION / SUBMITTAL APP URBAN DESIGN PLAN 46TH STREET & DIRECTION WESTBOUND 02-WB-2

15 KEYNOTES: GENERAL NOTES: PROVIDE 2-3" CONDUITS USING DIRECTIONAL BORING UNDER PAVEMENT SEE ENLARGED COMMUNICATION AND ELECTRICAL SITE PLANS FOR REMAINING COMMUNICATION AND POWER INSTALLATION WORK PROVIDE CONDUIT FROM ELECTRICAL CABINET TO XCEL UTILITY POLE 20/240V, P 3 RELOCATE, INSTALL AND WIRE SALVAGED LIGHTING UNIT, INCLUDING LUMINAIRE, POLE AND LIGHT BASE EXTEND CONDUIT AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY 4 PROVIDE CONDUIT FROM ELECTRICAL CABINET TO XCEL UTILITY POLE 20/240V, P, ABOUT 50' TO THE WEST OF ELECTRICAL CABINET 2 CONDUIT ROUTING SHOWN DIAGRAMMATICALLY, CONDUIT RUNS UNDER SIDEWALK SHALL BE RUN WITH MINIMAL BENDS CONDUIT RUNS WITH MORE THAN 270-DEGREES SHALL HAVE A PULLBOX OR HANDHOLE INSTALLED 3 SEE CORRESPONDING CONDUIT AND CABLE SCHEDULE FOR ITEMS TAGGED WITH 4 ALL CONDUITS SHALL BE CONTAINED IN RIGHT OF WAY UNLESS NOTED OTHERWISE 5 PROVIDE CONDUIT FROM SCC TO NEAREST UTILITY POLE WHERE INTERNET PROVIDER SERVICE DEMARCATION EXISTS PLACE HANDHOLE AT DEMARCATION LOCATION VERIFY ISP DEMARCATION LOCATION WITH CAR AND ISP BEFORE INSTALLING HANDHOLE OR CONDUIT 2 ELECTRICAL CABINET (MH4-SEC-0) COMMUNICATION CABINET (MH4-SCC-00) ROW 5 PYLON TVM-0 TVM-02 FCV-0 SHELTER FCV-02 (F) HH 0B 5 XCEL ENERGY UTILITY POLE 20/240V, P WITH CATV, TELCO PLANT 9A 9B 46TH STREET ELECTRICAL CABINET (MH4-SEC-20) MH4-HHL-20 FCV-202(F) SHELTER PYLON FCV-20 TVM-202 TVM-20 ROW NO DATE BY REVISION / SUBMITTAL APP POWER & COMMUNICATIONS PLAN 46TH STREET & DIRECTION EAST/WESTBOUND BRT-02- SHEET OF

16 4 5 6 ELECTRICAL CABINET COMMUNICATION CABINET (MH4-SCC-00) TVM-0 3 TVM-02 FCV-0 2 FCV-02 (F) PYLON SHELTER HH KEYNOTES: RELOCATE, INSTALL AND WIRE SALVAGED LIGHTING UNIT, INCLUDING LUMINAIRE, POLE AND LIGHT BASE EXTEND CONDUIT AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY 46TH STREET 46TH STREET GENERAL NOTES: SEE ENLARGED COMMUNICATION SITE PLAN FOR REMAINING COMMUNICATION INSTALLATION WORK MH4-HHL-20 2 CONDUIT ROUTING SHOWN DIAGRAMMATICALLY, CONDUIT RUNS UNDER SIDEWALK SHALL BE RUN WITH MINIMAL BENDS CONDUIT RUNS WITH MORE THAN 270-DEGREES SHALL HAVE A PULLBOX OR HANDHOLE INSTALLED 3 SEE CORRESPONDING CONDUIT AND CABLE SCHEDULE FOR ITEMS TAGGED WITH SHELTER 4 ALL CONDUITS SHALL BE CONTAINED IN RIGHT OF WAY UNLESS NOTED OTHERWISE FCV-202(F) 32 FCV-20 TVM-202 TVM-20 PYLON NO DATE BY REVISION / SUBMITTAL APP ENLARGED POWER PLAN 46TH STREET & DIRECTION EAST/WESTBOUND BRT-02-2 SHEET OF

17 NOT TO SCALE NOT TO SCALE NO DATE BY REVISION / SUBMITTAL APP ELECTRICAL SCHEDULES 46TH STREET & DIRECTION EAST/WESTBOUND BRT-02-3 SHEET OF

18 ELECTRICAL CABINET (MH4-SEC-0) COMMUNICATION CABINET (MH4-SCC-00) 2 5B 0B 9A 9B A B 4B 6A 4A 6B 7A TVM-0 TVM-02 FCV-02(F) SHELTER 7B PYLON FCV-0 ETL-0 8A MH4-HHL-02 9A 9B GENERAL NOTES: DEVICES TO BE INSTALLED BY OTHERS AT A LATER DATE; ARE SHOWN ON THIS SHEET FOR REFERENCE ONLY 46TH STREET 2 CONDUIT ROUTING SHOWN DIAGRAMMATICALLY, CONDUIT RUNS UNDER SIDEWALK SHALL BE RUN WITH MINIMAL BENDS CONDUIT RUNS WITH MORE THAN 270-DEGREES SHALL HAVE A PULLBOX OR HANDHOLE INSTALLED 46TH STREET /8"='-0" 3 SEE CORRESPONDING CONDUIT AND CABLE SCHEDULE FOR ITEMS TAGGED WITH 4 ALL CONDUITS SHALL BE CONTAINED IN RIGHT OF WAY UNLESS NOTED OTHERWISE 25B 2 9A 9B MH4-HHL-20 KEYNOTES: PROVIDE 2-3" CONDUITS LOCATED UNDER PAVEMENT BY DIRECTIONAL BORING 24A 2 PROVIDE CONDUIT FROM ELECTRICAL CABINET TO COMMUNICATIONS CABINET/HANDHOLE ETL-20 28A 24B SHELTER FCV-20 TVM-202 TVM-20 27A 26B PYLON FCV-202(F) 27B 2A 2B 26A /8"='-0" NO DATE BY REVISION / SUBMITTAL APP ENLARGED COMMUNICATIONS PLAN 46TH STREET & DIRECTION EAST/WESTBOUND BRT-02-4 SHEET OF

19 GENERAL NOTES: SEE SITE PLANS AND ENLARGED SITE PLANS FOR LOCATIONS OF CONDUITS 2 CONDUIT NUMBERS CORRELATE TO NUMBERS ON PLAN SHEETS AND ELEVATIONS 2 2 KEYNOTES: TERMINATE UNDERSLAB CONDUITS TO JUNCTION BOX PROVIDED AS PART OF PREFABRICATED SHELTER 2 TERMINATE UNDERSLAB CONDUITS TO JUNCTION BOX PROVIDED AS PART OF PRE-FABRICATED PYLON 2 2 NO DATE BY REVISION / SUBMITTAL APP COMMUNICATION SYSTEMS CABLE AND CONDUIT SCHEDULE 46TH STREET & DIRECTION EAST/WESTBOUND BRT-02-5

POWER SERVICE DETAILS

POWER SERVICE DETAILS POWER SOURCE # POLE MOUNTED SERVICE TRANSFORMER BY POWER HANDHOLE 0/0V, -PHASE, SERVICE CONDUCTORS; -# AWG SERVICE CONDUCTOR AND -# AWG GROUNDED SERVICE CONDUCTOR (NEUTRAL) SERVICE XFMR SECONDARY. A 0V

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

ARCHITECT/ENGINEER ALARM ANNUNCIATOR PANEL AC ALTERNATING CURRENT OR ARMORED CABLE ACCESSIBLE

ARCHITECT/ENGINEER ALARM ANNUNCIATOR PANEL AC ALTERNATING CURRENT OR ARMORED CABLE ACCESSIBLE 1PH SINGLE-PHASE 1P SINGLE POLE 2/C TWO-CONDUCTOR 3/C THREE-CONDUCTOR 3PH THREE-PHASE 4/C FOUR-CONDUCTOR 4W FOUR-WIRE A/C UNIT A/E AAP AIR CONDITIONING UNIT ARCHITECT/ENGINEER ALARM ANNUNCIATOR PANEL AC

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Creating Electrical Designs

Creating Electrical Designs C h a p t e r 2 Creating Electrical Designs In this chapter, we will learn the following to World Class standards: Understanding Control and Power Circuits Drawing the Control Circuit Selecting the Pushbutton

More information

SECTION EQUIPMENT WIRING

SECTION EQUIPMENT WIRING PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 26 27 17 EQUIPMENT WIRING A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General Provisions,

More information

Quality Control Checklist - Design Drawings

Quality Control Checklist - Design Drawings Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not

More information

Wisconsin Contractors Institute Continuing Education

Wisconsin Contractors Institute Continuing Education IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you

More information

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems Text Book: Chapter 2. Understanding Electrical Drawings, Electric Motors and Control

More information

Electrical IP Red Seal Practice Exam

Electrical IP Red Seal Practice Exam Electrical IP Red Seal Practice Exam PRACTICE EXAM-3 1. What size 2 pole breaker must you use on a 3HP, 115V single phase motor? A. 40A B. 50A C. 80A. D. 100A. 2. An electrical equipment approved for use

More information

DIVISION 26 ELECTRICAL SECTION ELECTRICAL

DIVISION 26 ELECTRICAL SECTION ELECTRICAL DIVISION 26 ELECTRICAL SECTION 26 1000 ELECTRICAL PART 1 - GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the Electrical System as shown

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SINGLE-PHASE VSV SWITCH

SINGLE-PHASE VSV SWITCH May 2006 Supercedes: March 2006 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...2 IV. Maintenance...4 V. VSV Power

More information

Construction Electrician/Industrial Electrician/Power Electrician Common Core Level 2

Construction Electrician/Industrial Electrician/Power Electrician Common Core Level 2 Common Core Level 2 Unit: B1 Commercial Electrical Code Level: Two Duration: 60 hours Theory: Practical: 60 hours 0 hours Overview: This unit is designed to provide the apprentice with the knowledge about

More information

NORTHWEST FLORIDA STATE COLLEGE MONUMENT SIGNS WITH LED DISPLAYS

NORTHWEST FLORIDA STATE COLLEGE MONUMENT SIGNS WITH LED DISPLAYS PREPARED FOR: FOUNDATION PLAN & STRUCTURAL NOTES DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S1 PREPARED FOR: FRAMING PLANS DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S2 PREPARED FOR: SECTION

More information

pi2ig-l 1988 STANDARD for GRAPHIC ELECTRICAL/ 00 ELECTRONIC AIR-CONDITIONING AND REFRIGERATING EQUIPMENT SYMBOLS FOR AIR-CONDITIONING

pi2ig-l 1988 STANDARD for GRAPHIC ELECTRICAL/ 00 ELECTRONIC AIR-CONDITIONING AND REFRIGERATING EQUIPMENT SYMBOLS FOR AIR-CONDITIONING 1988 STANDARD for STANDARD for GRAPHIC ELECTRICAL/ 00 ELECTRONIC s SYMBOLS FOR AIR-CONDITIONING AND REFRIGERATING EQUIPMENT 0 I AIR-CONDITIONING & REFRIGERATION INSTITUTE pi2ig-l 1501 WILSON BOULEVARD

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

SINGLE-PHASE VSV SWITCH

SINGLE-PHASE VSV SWITCH Revision: September 2009 Supersedes: August 2007 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...3 IV. Maintenance...5

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems Text Book: Chapter 2. Understanding Electrical Drawings, Electric Motors and Control

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights 1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights These 1 Exam Prep Tabs are based on NFPA 70: National Electrical Code, 2011. Each 1 Exam Prep Tabs sheet has five rows of Tabs. Start

More information

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit. ECET4520 Exam II Sample Exam Problems Instructions: This exam is closed book, except for the reference booklet provided by your instructor and one (8.5 x11 ) sheet of handwritten notes that may not contain

More information

Michigan State University Construction Standards WIRING DEVICES PAGE

Michigan State University Construction Standards WIRING DEVICES PAGE PAGE 262726-1 SECTION 262726 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY. Test Code: 5171 Version: 01

TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY. Test Code: 5171 Version: 01 TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY Test Code: 5171 Version: 01 Specific Competencies and Skills Tested in this Assessment: OSHA Regulations and Electrical Safety Practices

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING 1 1 1 1 1 NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING NORTH CAROLINA BUILDING CODE COUNCIL Notice of Rule-making Proceedings is hereby given by NC Building Code Council in accordance with G.S.

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201 Low Voltage Products Third Harmonic Filter and star System components for assembly and retrofitting Catalogue SGB _ SCCC System components for assembly and retrofitting star, installation in the transformer

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 13 DISTRIBUTION SWITCHBOARDS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Industrial Electrician Level 3

Industrial Electrician Level 3 Industrial Electrician Level 3 Industrial Electrician Unit: C1 Industrial Electrical Code I Level: Three Duration: 77 hours Theory: Practical: 77 hours 0 hours Overview: This unit is designed to provide

More information

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION October 2014 TECHNICAL DESCRIPTION 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES I. SCOPE This

More information

BGE STRATEGIC CUSTOMER ENGINEERING

BGE STRATEGIC CUSTOMER ENGINEERING TABLE OF CONTENTS 1. GENERAL. 2 2. BGE SUPPLY FEEDER. 4 3. SWITCHGEAR ENCLOSURE AND ASSEMBLY. 5 4. CIRCUIT BREAKER. 9 5. SWITCHGEAR EQUIPMENT... 10 6. MAIN AND GROUND BUS.... 15 7. GROUND AND TEST DEVICE.

More information

Article 250 Grounding & Bonding

Article 250 Grounding & Bonding Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education

More information

MV network design & devices selection EXERCISE BOOK

MV network design & devices selection EXERCISE BOOK MV network design & devices selection EXERCISE BOOK EXERCISES 01 - MV substation architectures 02 - MV substation architectures 03 - Industrial C13-200 MV substation 04 - Max. distance between surge arrester

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4 SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 16.10.1 INTRODUCTION 16.10.1.1 The intent of this standard is to ensure that continuity

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

3Ø Short-Circuit Calculations

3Ø Short-Circuit Calculations 3Ø Short-Circuit Calculations Why Short-Circuit Calculations Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 11 SPEC WRITER NOTES: Use this section only for NCA projects. Delete between // -- // if not applicable to project. Also delete any other item or paragraph

More information

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending

More information

Accessories Field Installable

Accessories Field Installable ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC 0 2 Contact rrangement 51 61 52 62 For use with... Standard Contacts Bifurcated Contacts ➋ C7 all CS7-PV-02

More information

HPS Universal BUCK-BOOST TRANSFORMERS

HPS Universal BUCK-BOOST TRANSFORMERS BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Residential Construction Checklist Single and Two Family Construction

Residential Construction Checklist Single and Two Family Construction DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy

More information

Chapter 25. Lighting Plans

Chapter 25. Lighting Plans Chapter 25 Lighting Plans The following are changes, additions or deletions to the January 2014, Topic #625-000-008, Plans Preparation Manual (PPM), for use on Turnpike projects only. 25.1 General Replace

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

Impact Assessment Generator Form

Impact Assessment Generator Form Impact Assessment Generator Form This connection impact assessment form provides information for the Connection Assessment and Connection Cost Estimate. Date: (dd/mm/yyyy) Consultant/Developer Name: Project

More information

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL BELL SYSTEM PRACTICES Plant Series SECTION 508-100-100 Issue 3, October 1970 AT&TCo Standard ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL I. GENERAL 1.01 This section is reissued to: Revise

More information

SECTION LIGHTING

SECTION LIGHTING SECTION 16500 - LIGHTING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Customer Connection Guide Updates Effective May 2017

Customer Connection Guide Updates Effective May 2017 This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services

More information

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and

More information

Electrical Standards Division 16

Electrical Standards Division 16 Design Guidelines and Standards Electrical Standards Division 16 November 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 ELECTRICAL SPECIFICATIONS

More information

NEMA Size 1 Cat. No. CN55DN3AB

NEMA Size 1 Cat. No. CN55DN3AB -80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5 Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction

More information

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components:

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components: SECTION 275123 INTERCOMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Manually switched intercommunications systems with the following components: 1. Master stations (EXISTING).

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Chapter 6. WIRING SYSTEMS Safe Electrical Design Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 16 FROM:

More information

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage

More information

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN SUBMITTAL REVIEW Submittal: No. 019.00 Spec Section: 26 0000, 28 0000 Complete Elec, Comm, and Fire Alarm Reviewed By: Laura Landon, Comma-Q Architecture Date: June 29, 2012 Project: BPS Belgrade Elementary

More information

HOENER ASSOCIATES INC. ARCHITECTS

HOENER ASSOCIATES INC. ARCHITECTS HOENER ASSOCIATES INC. ARCHITECTS BRUCE D. DELL MARK REUTHER ADDENDUM NO. 1 PROJECT 15-22C RENOVATION AND SITE WORK AT: BUILDING B DDRB OF ST. CHARLES DEVELOPMENT DISABILITIES RESOURCE BOARD ST. CHARLES,

More information

SECTION TRANSFORMERS

SECTION TRANSFORMERS SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section

More information

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv) Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be

More information

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.1 SUMMARY DISCONTINUED PRODUCT GUIDE SPECIFICATIONS 15-75 kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL These specifications describe requirements for a complete power conditioning and

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop 500 460 MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop Check if Applicable TRAFFIC SIGNAL SPECIAL DETAILS INDEX/CHECKLIST *One completed checklist required

More information

The Variable Threshold Neutral Isolator (VTNI)

The Variable Threshold Neutral Isolator (VTNI) The Variable Threshold Isolator (VTNI) Installation Instructions INTRODUCTION The is designed specifically for installation between the primary neutral of a power utility distribution system and the secondary

More information

+ 24V 3.3K - 1.5M. figure 01

+ 24V 3.3K - 1.5M. figure 01 ELECTRICITY ASSESSMENT 35 questions Revised: 08 Jul 2013 1. Which of the wire sizes listed below results in the least voltage drop in a circuit carrying 10 amps: a. 16 AWG b. 14 AWG c. 18 AWG d. 250 kcmil

More information

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice. Instruction Manual Bypass Panels FRENIC-EcoPAK Fuji Electric Corp. of America FECA-IN-105 / 122010 Information subject to change without notice. Safety Precautions Read this manual thoroughly before proceeding

More information

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS 9/8/98 AC 43.13-1B SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS 11-271. GENERAL. The electrical and electronic symbols shown here are those that are likely to be encountered by the aviation maintenance

More information

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102 G e m i n i high RESISTANCE GROUNDING SYSTEM the power to protect Instruction Manual C-102 HIGH RESISTANCE GROUNDING SYSTEM Gemini is a unique, fail safe, all-in-one neutral grounding system, combining

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0, 8'-0, 10'-0 NOMINAL SPREAD (SEE CONTRACT) POLE CAP Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"

More information

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT A. General In a hazardous location grounding of an electrical power system and bonding of enclosures of circuits and electrical equipment in the

More information

FDM Medium Voltage Controller

FDM Medium Voltage Controller 1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller

More information

Journeyman's Practice Exam

Journeyman's Practice Exam Journeyman's Practice Exam [Time limit 4.0 hrs.] (The test is open book. I've started at the front of the Code Book and worked toward the back for instructional purposes. The real test will not be in order

More information

ELPT 1429 RESIDENTIAL WIRING

ELPT 1429 RESIDENTIAL WIRING SYLLABUS ELPT 1429 RESIDENTIAL WIRING INDUSTRIAL AND COMMERCIAL ELECTRICITY BRAZOSPORT COLLEGE LAKE JACKSON TEXAS PREPARED BY: Larry Grable DATE: September 13, 2005 INSTRUCTOR RECOMMENDED BY: RECOMMENDED

More information

VI 3 - i TABLE OF CONTENTS

VI 3 - i TABLE OF CONTENTS VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3

More information

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201 Low Voltage Products Enclosed Third Harmonic Filter and star Enclosed units Brochure S1GB 3_4 1SCC333C21 The Third Harmonic - a Growing Problem Today's electrical networks and plants are under much more

More information

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................

More information

Grounding and Bonding of Service Equipment

Grounding and Bonding of Service Equipment Grounding and Bonding of Service Equipment 1. Grounding means: attached to an earth ground. 2. Bonding means: physically connected to insure electrical continuity. NEC 250.4 1. Grounding: Electrical Systems

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

2017 NEC TABLE OF CONTENTS

2017 NEC TABLE OF CONTENTS Article 90 Introduction 90.1 Purpose (A) Practical Safeguarding (B) Adequacy (C) Relation to Other International Standards 90.2 Scope (A Covered (B) Not Covered (C) Special Permission 90.3 Code Arrangement

More information

City of Palm Coast. 160 Cypress Point Parkway, Suite B-106 Palm Coast, FL Tel (386)

City of Palm Coast. 160 Cypress Point Parkway, Suite B-106 Palm Coast, FL Tel (386) ITB-C-CM-14-11 Holland Park Improvements ISSU AT: July 24, 2014 BI AT: SUBJCT: INTNT: August 11, 2014 @ 2:00 PM ANUM NO. 01 City of Palm Coast 160 Cypress Point Parkway, Suite B-106 Palm Coast, FL 32164

More information

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems UNITY/I TM UT3K, UT4K, UT5K and UT8K Single-Phase Uninterruptible Power Systems Installation Manual MLS-0351C-OL Copyright 1994-1997 Best Power. All rights reserved. å IMPORTANT SAFETY INSTRUCTIONS! SAVE

More information