Journeyman's Practice Exam

Size: px
Start display at page:

Download "Journeyman's Practice Exam"

Transcription

1 Journeyman's Practice Exam [Time limit 4.0 hrs.] (The test is open book. I've started at the front of the Code Book and worked toward the back for instructional purposes. The real test will not be in order believe me!) 1. True or False: The code was intended to be used as an instructional manual. (a) T (b) F 2. True or False: The Code cover all electrical installations in the United States and it's territories. (a) True (b) False 3. True or False: Mandatory Rules are noted by the word shall. (a) True (b) False 4. If you have to use a ladder to reach an on/off switch for a piece of outdoor equipment you would classify that switch as being: (a) accessible (b) code violation (c) readily accessible (d) approved

2 5. The ratio of the maximum demand of a system, part of a system, to the total connected load of a system or part of the system under consideration is: (a) Demand Factor (b) Inverse Square Law (c) Industry Standard (d) Maxwell's Ratio 6. A motor starter is considered if it can be seen within 50 feet of the motor it controls. (a) Code Violation (b) In Sight From (c) Number 1 (d) Non-accessible 7. Termination provisions of equipment for circuits rated over 100 amperes, or marked for conductors larger than 1 AWG, shall be used only for : (a) copper wire (b) aluminum wire (c) 60 0 C (d) 75 0 C

3 8. On a 4-wire Delta-connected system where the midpoint of one phase winding is grounded shall be permanently marked what color? (a) any color other than green (b) purple (c) white (d) orange 9. Where working on a 120 volt system exposed to live parts on one side of a working space and no live or grounded parts on the other side of the working space you must have a minimum clearance of: (a) 3 ft (b) 3.5 ft (c) 4 ft (d) 4.5 ft 10. The minimum headroom of working spaces around service equipment, switchboards, panel boards, or motor control centers is: (a) 8ft (b) 6ft (c) 6.5ft (d) 4ft

4 11. An insulated grounded conductor larger than size 6 AWG shall be identified by which of the following: I-by a continuous white or gray finish; II-by three continuous white stripes along its entire length on other than green insulation; III-A distinctive white or gray marking at its terminals. (a) I-II (b) I (c) I-II-III (d) II-III 12. The rating of a branch circuit shall be determined by: (a) overcurrent device (b) the architect (c) the conductor size (d) the receptacle rating 13. True or False: Where two or more circuits supply power to equipment on the same yoke a means to simultaneously disconnect all the ungrounded conductors shall be installed in the panel board where the circuits originate. (a) T (b) F

5 14. Which of these room require at least one 20 Amp circuit in a dwelling? (a) bathroom (b) kitchen (c) laundry (d) all the above 15. Which of the following is not a true statement: I- I can load a 15A receptacle to 20A II- A 40A Heavy Duty lamp holder may be connected to 50A receptacle. (a) I only (b) II only (c) I or II (d) neither I or II 16. At least one receptacle must be mounted to peninsular counter space if its long dimension is or over and its short dimension is or over. (a) 10", 20" (b) 12", 24" (c) 24", 12" (d) 18", 14"

6 17. In dwelling units hallways of or more shall have at least one receptacle outlet installed. (a) 10ft (b) 12ft (c) 8ft (d) 6ft 18. The ampacity of a feeder shall not be less than that of the service conductors where the feeders carry the total load supplied by service conductors with an ampacity of amperes or less. (a) 100 (b) 50 (c) 55 (d) The first step in calculating a hospital s general lighting load would be to multiply the hospital's square foot area by VA. (a) 3 VA (b) 1/2 VA (c) 2 VA (d) 3 1/2 VA

7 Household dryers in an apartment building would have a demand factor of. (a) 100% (b) 80% (c) 50% (d) 65% 21. One 12KW range in a dwelling would have a demand of on the service? (a) 12KW (b) 9.6KW (c) 8KW (d) none of the above 22. Overhead conductors for festoon lighting shall not be smaller than AWG without a messenger wire. (a) 6 (b) 1/0 (c) 8 (d) 12

8 23. Overhead conductors over residential property and driveways, and whose commercial areas not subject to truck traffic, where the voltage does not exceed 300 volts to ground shall have a clearance of not less than ft. (a) 10 ft (b) 12 ft (c) 14 ft (d) 16 ft 24. The maximum number of disconnects for each supply of a large apartment complex shall be not more than. (a) 1 (b) 2 (c) 4 (d) For installations that supply not more than 2 two-wire branch circuits, the feeder or branch circuit disconnecting means shall have a rating of not less than. (a) 15 A (b) 20 A (c) 30 A (d) 60 A

9 26. Service conductors are considered outside the building when installed beneath of concrete. (a) 2 in (b) 4 in (c) 6 in (d) 12 in 27. Service lateral conductors must not be smaller than copper or aluminum. (a) #8, #6 (b) #6, #4 (c) #12, #10 (d) #3, #2/0 28. Service disconnecting means shall not be installed in: (a) bedrooms (b) laundry rooms (c) bathrooms (d) basements 29. Which one of these statements is not true concerning services: (a) For a one family dwelling the service disconnects shall not be less than 100 amperes. (b) Each ungrounded service conductor shall have overcurrent protection (c) The service overcurrent device shall be integral to the service disconnecting means (d) The maximum setting for ground fault protection shall be 1200 Amperes

10 30. True or False: Class H cartridge fuses of the renewable type shall only be used for replacement in existing installations where there is no evidence of tampering or over-fusing. (a) T (b) F 31. Grounding of non-current-carrying conductive materials enclosing electrical conductors or equipment shall be connected together to form a(n): (a) Electrical System Ground (b) Bonding Strap (c) Effective Ground-Fault Current Path (d) Ground Fault 32. An unintentional electrically conducting connection between an ungrounded conductor of an electrical circuit with its non-current-carrying metal parts is called: (a) short circuit (b) ground (c) ground-fault (d) arc flash 33. Alternating current systems of less than 50 volts shall be grounded under the following condition(s): (a) Where supplied by transformers exceeding 150volts to ground (b) Where supplied by a transformer whose supply system is ungrounded (c) Where installed as overhead conductors outside of buildings. (d) Either a, b, or c (e) None of the above

11 34. When paralleling service entrance conductors the accompanying equipment ground conductor shall not be smaller than : (a) #6 AWG (b) #1 AWG (c) #1/0 AWG (d) #2/0 35. Main Bonding Jumpers shall not be smaller than Table values and where larger than 1100kcmils copper or 1750kcmils aluminum, the bonding jumper shall have an area not less than : (a) 12 1/2% of the area of the largest phase conductor (b) 14 % of the largest aluminum conductor (c) 125% of the grounded conductor (d) equal to the largest phase conductor 36. The Equipment Grounding Conductor (EGC) shall be sized by: (a) Table (b) Table (c) Engineering formulas (d) Your Foreman

12 37. When using an underground metal water pipe for the Grounding Electrode Conductor it must be in contact with the earth for a distance of at least. (a) 8 ft (b) 10 ft (c) 12 ft (d) 25 ft 38. An electrode encased by at least 2" of concrete located within the footing that is in direct contact with the earth must be connected to the galvanized re-bar by a conductor not less than. (a) #4 AWG Bare copper (b) #6 AWG Stranded Aluminum (c) #8 AWG Bare Copper (d) #4 AWG Stranded Aluminum 39. A supplemental electrode bonding conductor need not be larger than: (a) #4 AWG copper (b) #6 AWG aluminum (c) #6 AWG copper (d) #2 AWG aluminum

13 40. A single electrode consisting of a pipe, rod, or plate that does not have a resistance to of ohms or less shall be augmented by one additional electrode. (a) 10 (b) 25 (c) 48 (d) What is the minimum size of the Grounding Electrode Conductor for an Alternating Current system that has service entrance conductors of 300kcmil? (a) #6 AWG aluminum (b) #8 AWG copper (c) #2 aluminum (d) #2 copper 42. Electrodes of pipe or conduit shall not be less than trade size? (a) 1/2" (b) 3/4" (c) 1" (d) 3/8" 43. The minimum size Equipment Grounding Conductor for a 100 A service is? (a) #8 copper (b) #8 aluminum (c) #6 copper (d) #4 aluminum

14 44. In both exposed and concealed locations where a cable or raceway is installed through bored holes in joists, rafters, or wood members, the holes shall be bored so that the edge of the hole is not less than inches from the nearest edge of the wood member? (a) 1/2 (b) 1 (c) 1 1/4 (d) 1 ½ 45. Where raceways containing ungrounded conductors of #4 AWG or larger enter a cabinet, box enclosure, or a raceway, the conductors shall be protected by a fitting with. (a) an insulated throat (b) marked volume (c) a steel lock ring (d) wire ties 46. What is the minimum burial depth for a 20A GFCI protected circuit underneath a residential driveway using PVC? (a) 18" (b) 12" (c) 24" (d) 6"

15 47. Direct buried conductors and enclosures emerging from grade shall be protected by enclosures or raceways extending from below grade to above grade. (a) 18", 8" (b) 12", 8' (c) 18", 8' (d) 24", 10' 48. True or False: If the splices are listed for the purpose it is allowable by the code to splice direct burial conductors? (a) T (b) F 49. What is the minimum number of supports required for a 100 ft vertical run of 3/0 AWG copper conductors? (a) 10 (b) 8 (c) 4 (d) Which wiring method is not allowed inside a duct or plenum used for environmental air? (a) Type MI Cable (b) EMT (c) 5 ft of Flexible Metal Conduit (d) Rigid Metal Conduit

16 51. Paralleled conductors shall comply with which of the following condition(s)? (a) Be the same length (b) Same conductor material (c) Same circular mil area (d) Have the same insulation (e) Terminated in the same manner (f) a, b, and c only (g) a, b, c, d, and e 52. By what percentage must the Table ampacity of 5 current-carrying conductors in the same raceway be derated? (a) 45% (b) 50% (c) 70% (d) 80% 53. What is the minimum size service entrance conductor for a single phase 120/240V 3-wire hook-up for a 150 amp service? (a) 1/0 AWG (b) 1 AWG (c) 2 AWG (d) 4 AWG

17 54. What is the ampacity of a #6AWG copper conductor at an ambient temperature of 86 o F in a system that uses 60 o C terminations? (a) 40 A (b) 55 A (c) 45.4 A (d) 70 A 55. What is the allowable ampacity of three 350kcmil aluminum conductors in the same raceway in an ambient temperature of 30 o C? (a) 260 A (b) 310 A (c) 210 A (d) 250 A 56. By what factor would you multiply the Table ampacity of a #6 copper conductor installed in an ambient temperature of 131 o F? (a).76 (b).67 (c).41 (d).71

18 57. What is the minimum wire-bending space required for three 1/0 conductors at one terminal? (a) 3" (b) 5.5" (c) 7" (d) 6 1/2" 58. True or False: Nonmetallic boxes shall be permitted only with open wiring on insulators, concealed knob and tube wiring, cabled wiring methods with entirely nonmetallic sheaths, flexible cords, and nonmetallic raceways. (a) T (b) F 59. When figuring boxfill, the volume of each #10 AWG copper conductor entering the junction box shall be calculated at in 3? (a) 1.75 (b) 2.50 (c) 2.00 (d) What is the minimum size junction box permitted for a calculated wire volume of 29.5 in 3? (a) 4 x 1 ¼ square box (b) 4 11/16 x 1 ½ square box (c) 4 x 1 ½ square box (d) 4 11/16 x 2 1/8 square box

19 61. Boxes in walls or ceilings of non-combustible material, employing a flush-type cover or faceplate shall not be set back of the finished surface more than: (a) 1/8" (b) 1/4" (c) 3/16" (d) 5/16" 62. Raceway supported enclosures with devices, luminaires, or lamp holders shall not have a volume greater than in 3. (a) 60 (b) 80 (c) 100 (d) Boxes for ceiling suspended paddle fans shall be listed for the purpose and shall not support ceiling fans that weight more than lbs. (a) 70 (b) 35 (c) 80 (d) 65

20 64. For straight pulls the length of a junction box over 600Volts shall not be less than times the outside diameter of the largest lead-covered conductor entering the box and times the outside diameter of the largest unshielded conductor or cable. (a) 24, 34 (b) 32, 48 (c) 34, 24 (d) 48, Type MC cable shall not be used where exposed to the following condition(s): (a) Direct burial (b) In concrete (c) both a and b (d) a only (e) b only 66. Exposed vertical risers of IMC conduit supplying industrial machinery shall be supported not less than every ft. (a) 4 (b) 10 (c) 15 (d) 20

21 67. What is the minimum bending radius of a 1.5" nonmetallic underground conduit with conductors? (a) 20" (b) 18" (c) 16" (d) 12" 68. SJO cable has insulation. (a) Thermoplastic (b) Thermoset (c) Cotton (d) Rubber 69. Storage type water heaters that have a capacity of 120 gal. or less shall be considered: (a) a Code violation (b) non-continuous load (c) continuous load (d) average load 70. A motor with a locked rotor current of 10 A would have the code letter on its nameplate. (a) A (b) E (c) H (d) M

22 71. Conductors supplying several motors and/or other loads shall have an ampacity of not less than % of the full load current rating of the rated motor of the group plus the sum of all the other loads. (a) 100, lowest (b) 115, highest (c) 125, lowest (d) 125, highest 72. A 1.5HP continuous duty motor has a nameplate full load current rating of 20A. What is the maximum trip setting allowed for a separate overload device controlling this motor? (a) 20A (b) 23A (c) 25A (d) 30A 73. True or False: You must never install a motor overload device to trip a grounded conductor. (a) T (b) F 74. What is the Full Load Current of a 480Volt 3-phase 10HP AC motor? (a) 14A (b) 12A (c) 16A (d) 18A

23 75. Which of the following are you allowed to utilize an attachment plug as the disconnecting means? I- room air conditioner II-household refrigerator III-beverage dispenser IV-drinking water cooler. (a) II, IV (b) I, II, III (c) I, II, III, IV (d) II, III, IV 76. The total marked rating of a cord-and-plug connected room air conditioner shall not exceed % of the branch circuit rating. (a) 80 (b) 60 (c) 50 (d) Individual Dry-Type transformers of more than 112.5KVA rating shall be installed in a(n) room. (a) 10' x 15' (b) outdoor (c) fire resistant (d) basement

24 78. The walls and floors of transformer vaults shall have a minimum fire resistance rating of hours. (a) 4 (b) 3 (c) 2 (d) An area that dispenses gasoline, within 5ft of the pump, would be classified as a Class Division hazardous area. (a) I, 1 (b) I, 2 (c) II, 2 (d) III, A Class II, Division 1 location is one in which is (are) in the air under normal operating conditions in quantities sufficient to produce and explosion. (a) gases (b) dust (c) fibers (d) asbestos

25 81. Equipment must be marked to show the environment for which it has been evaluated. A temperature marking of T4 would signify a temperature of o F? (a) 536 (b) 392 (c) 185 (d) In healthcare facilities both the Alternate source and the normal source of power shall be connected to the Equipment System, Life Safety Branch, and Critical Branch by? (a) Direct Connection (b) Transfer Switch Arrangement (c) Parallel Conductors (D) Series Conductors 83. Individual branch circuits shall not be required for portable medical X-ray equipment requiring a capacity of not over A? (a) 20 (b) 30 (c) 40 (d) 60

26 84. Fixed Stage Equipment such as footlights, border lights, and sidelights shall be arranged so that no branch circuit supplying such equipment carries a load in excess of A? (a) 10 (b) 12 (c) 16 (d) Where GFCI protection is required in supplying carnival concession stand, the GFCI cam be a part of the cord provided it is within of the attachment plug? (a) sight from (b) 12 inches (c) 36 inches (d) 6 ft 86. Which of these locations concerning Mobile Homes does not require GFCI receptacle(s)? (a) within 25 ft of outside A/C unit (b) in the bathroom (c) within 8 ft of a wet bar (d) kitchen countertop

27 87. All metal parts inside and outside of a mobile home must be connected to a ground bus within the distribution panel; and in turn connected to the service panel by an insulated green conductor. Neither the frame of the mobile home or any appliance ground connected within shall be connected to the? (a) ungrounded conductor (b) grounded conductor (c) equipment ground (d) meter socket 88. The demand factor for the main service in a mobile home park housing 60 mobile homes shall be reduced to of its total calculated load? (a) 100% (b) 39% (c) 23% (d) 50% 89. The Electrical Datum Plane at a Marina or boatyard is said to be a horizontal plane ft above the highest water level under normal circumstances including tides. (a) 2 (b) 4 (c) 6 (d) 8

28 90. Each commercial building and each commercial occupancy, accessible to pedestrian traffic shall be provided with at least one amp outlet at each entrance for sign or outline lighting. (a) 10 (b) 15 (c) 20 (d) Traveling cables of elevators shall be permitted to be in lengths not over ft when looping cables around supports for strain relief. (a) 25 (b) 50 (c) 75 (d) Conductors that supply one or more Arc Welders shall be protected by an overcurrent device rated or set at not more than % of the conductor ampacity. (a) 80 (b) 100 (c) 125 (d) 200

29 93. Overhead service entrance cables routed directly over an outside swimming pool shall be at least ft over the surface of the water. (a) 15 (b) 18 (c) 25 (d) The minimum burial depth for rigid conduit to supply an in-ground swimming pool is? (a) 6" (b) 18" (c) 24" (d) 12" 95. All 15 and 20-ampere single phase 125 Volt receptacles located within ft of the inside wall of pools and shall be GFCI protected. (a) 5 (b) 12 (c) 20 (d) 25

30 96. All forming shells for wet niche underwater luminaires shall include provisions for grounding with a AWG copper conductor. (a) #4 (b) #6 (c) #8 (d) # In the event of failure of the normal supply to, or within the building or group of buildings that require emergency power, emergency lighting, emergency power or both shall be available within a time not to exceed. (a) 10 seconds (b) 15 seconds (c) 30 seconds (d) 45 seconds 98. Which of the following supply conductors are not allowed in a raceway that encloses emergency circuits? (a) exit light (b) egress illumination (c) security alarm (d) fire alarm

31 99. Communications wires and cables shall have a vertical clearance of not less than ft over roof tops. (a) 3 (b) 4 (c) 8 (d) Type communications cable shall be permitted for one and two family dwellings. (a) CMX (b) CMR (c) CMUC (d) CMG feet of Amateur Radio Station outdoor antenna conductors shall be of hard drawn copper not less than AWG. (a) 14 (b) 12 (c) 6 (d) 10

32 102. What percentage of cross sectional area of a ¾ rigid conduit, 30 ft. long, shall be permitted to contain current-carrying conductors? (a) 20% (b) 40% (c) 60% (d) 80% 103. What percentage of cross section of conduit shall be occupied by current-carrying conductors in a 3/4" EMT conduit 24" long? (a) 20 (b) 40 (c) 60 (d) If the total calculated cross sectional area of conductors was 3.500in 2 what is the minimum size conduit required for a forty foot run of EMT? (a) 2" (b) 3" (c) 4" (d) 5"

33 105. What is the maximum number of #12THW conductors allowed to be installed inside a 1.5" Rigid Metal conduit? (a) 39 (b) 32 (c) 25 (d) 15

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 200-215.3 CHANGES FROM 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 200 Use and Identification of Grounded Conductors 200.2 General Grounded Conductors

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

Wisconsin Contractors Institute Continuing Education

Wisconsin Contractors Institute Continuing Education IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you

More information

Article 250 Grounding & Bonding

Article 250 Grounding & Bonding Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education

More information

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights 1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights These 1 Exam Prep Tabs are based on NFPA 70: National Electrical Code, 2011. Each 1 Exam Prep Tabs sheet has five rows of Tabs. Start

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Continued from Part 1 Rules 1 25.

Continued from Part 1 Rules 1 25. Continued from Part 1 Rules 1 25. 26 225.32 Disconnect Location The disconnecting means for a building or structure must be installed at a readily accessible location, either outside the building or structure

More information

2017 NEC TABLE OF CONTENTS

2017 NEC TABLE OF CONTENTS Article 90 Introduction 90.1 Purpose (A) Practical Safeguarding (B) Adequacy (C) Relation to Other International Standards 90.2 Scope (A Covered (B) Not Covered (C) Special Permission 90.3 Code Arrangement

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33 Part VIII Electrical CHAPTER 33 GENERAL REQUIREMENTS < SECTION E3301 GENERAL E3301.1 Scope. The installation of electrical systems, equipment and components indoors and outdoors that are within the scope

More information

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit. ECET4520 Exam II Sample Exam Problems Instructions: This exam is closed book, except for the reference booklet provided by your instructor and one (8.5 x11 ) sheet of handwritten notes that may not contain

More information

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT A. General In a hazardous location grounding of an electrical power system and bonding of enclosures of circuits and electrical equipment in the

More information

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING 1 1 1 1 1 NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING NORTH CAROLINA BUILDING CODE COUNCIL Notice of Rule-making Proceedings is hereby given by NC Building Code Council in accordance with G.S.

More information

CHAPTER 2 Wiring and Protection. Article 200 Use and Identification of Grounded Conductors

CHAPTER 2 Wiring and Protection. Article 200 Use and Identification of Grounded Conductors ARTICLE 200 USE AND IDENTIFICATION OF GROUNDED CONDUCTORS 70 35 CHAPTER 2 Wiring and Protection Article 200 Use and Identification of Grounded Conductors 200-1. Scope. This article provides requirements

More information

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5 Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

Electrical Wiring: Commercial, Seventh Canadian Edition

Electrical Wiring: Commercial, Seventh Canadian Edition Electrical Wiring Commercial Canadian 7th Edition Mullin SOLUTIONS MANUAL Full download at: https://testbankreal.com/download/electrical-wiring-commercialcanadian-7th-edition-mullin-solutions-manual/ Unit

More information

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS Residential Pool Permit Requirements FEES: A nonrefundable permit application fee of $25.25 and a nonrefundable plan review fee of $40.40 will be

More information

Department of Labor and Industry Electrical Licensing

Department of Labor and Industry Electrical Licensing Department of Labor and Industry Electrical Licensing License Examination Guide The information in this guide is provided by the Licensing Unit of the Department of Labor and Industry to ensure that applicants

More information

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate. Part N: Code Book Questions Article 700: Emergency Systems 1.! For emergency systems, the authority having jurisdiction shall conduct or witness a test on the! complete system upon installation and periodically

More information

Code Check Electrical is a field guide to common code issues in residential

Code Check Electrical is a field guide to common code issues in residential INTRODUCTION u CODES u ABBREVIATIONS Code 3Check Electrical 5th Edition By Redwood Kardon & DOUGLAS HANSEN Illustrations & Layout: Paddy Morrissey 2008 by The Taunton Press, Inc. ISBN 978-1-60085-012-7

More information

ECET Fall 2017 Name: _ Lab Assignment #01

ECET Fall 2017 Name: _ Lab Assignment #01 ECET 4520 - Fall 2017 Name: _ Lab Assignment #01 General Instructions: This assignment is to be completed individually. All answers/work required for each problem should be neatly written in the space

More information

We have 3 ways to help you prepare

We have 3 ways to help you prepare P a g e 2 Texas Electrical Excel is your source for obtaining your license state exam. Call us if you have questions regarding your applications, exam preparation, exam registration and more. We have reached

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition Jake Leahy s Electrical Code Connection A look at Grounding and Bonding of Electrical Services Article 250 2014 Florida Building Code 5 th Edition Wiring Integrity. Completed wiring installations shall

More information

Electrical IP Red Seal Practice Exam

Electrical IP Red Seal Practice Exam Electrical IP Red Seal Practice Exam PRACTICE EXAM-3 1. What size 2 pole breaker must you use on a 3HP, 115V single phase motor? A. 40A B. 50A C. 80A. D. 100A. 2. An electrical equipment approved for use

More information

Module 2 Unit 6, 7, 8

Module 2 Unit 6, 7, 8 Module 2 Unit 6, 7, 8 1. What is the definition of an ideal conductor? Material that will carry the greatest current with the lowest temperature rise 2. How much does copper weigh compared to aluminum?

More information

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56 1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked

More information

RADIO AND TELEVISION SATELLITE EQUIPMENT

RADIO AND TELEVISION SATELLITE EQUIPMENT ARTICLE 810 RADIO AND TELEVISION SATELLITE EQUIPMENT Introduction to Article 810 Radio and Television Satellite Equipment This article covers transmitter and receiver (antenna) equipment and the wiring

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL BELL SYSTEM PRACTICES Plant Series SECTION 508-100-100 Issue 3, October 1970 AT&TCo Standard ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL I. GENERAL 1.01 This section is reissued to: Revise

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

A. Product Description: Stranded conductor insulated wire.

A. Product Description: Stranded conductor insulated wire. SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.

More information

2014 NEC Changes Part 1

2014 NEC Changes Part 1 www.garyklinka.com Page 1 of 8 Instructions: Fee $20 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms

More information

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings SOLAR MICROINVERTER/M STANDARD PLAN - COMPREHENSIVE Microinverter and M Systems for One- and Two- Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters or Modules

More information

PROVINCE.OF BRITISH COLUMBIA. ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL

PROVINCE.OF BRITISH COLUMBIA. ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL PROVINCE.OF BRITISH COLUMBIA ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL Order in Council No. 0640 Approved and Oidered a -1.1995 cieuisvunigott3mor Executive Council Chambers, Victoria On the recommendation

More information

SECTION 5 TRANSFORMERS

SECTION 5 TRANSFORMERS SECTION 5 TRANSFORMERS Necessary transformers will be installed and maintained by The City of Aspen. The City of Aspen will not furnish transformers unless they are of standard size and voltage as established

More information

INTRODUCTION...xiii Author s Comments...xiii Exam Preparation...xiii Difficult Concepts...xiv Textbook Errors and Corrections...xv Internet...

INTRODUCTION...xiii Author s Comments...xiii Exam Preparation...xiii Difficult Concepts...xiv Textbook Errors and Corrections...xv Internet... INTRODUCTION...xiii Author s Comments...xiii Exam Preparation...xiii Difficult Concepts...xiv Textbook Errors and Corrections...xv Internet...xv UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1

More information

STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST

STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST Item Comments 1. The electrical plan check is approved and ready to have the electrical permit issued, pending the building permit being issued.

More information

Chapter 1 Electrical Theory and Part C Series Parallel and Code Questions Multiwire Branch Circuits Unit 1 Electrician s Math

Chapter 1 Electrical Theory and Part C Series Parallel and Code Questions Multiwire Branch Circuits Unit 1 Electrician s Math Chapter 1 Electrical Theory and Code Questions 1 Unit 1 Electrician s Math and Basic Electrical Formulas 3 Part A Electrician s Math 3 1 1 Fractions 3 1 2 Kilo 4 1 3 Knowing Your Answer 4 1 4 Multiplier

More information

Wiring Methods, Components, and Equipment for General Use -- OSHA Standard

Wiring Methods, Components, and Equipment for General Use -- OSHA Standard ABE285 Wiring Methods, Components, and Equipment for General Use -- OSHA Standard 1910.305 1 Carol J. Lehtola, Charles M. Brown, and William J. Becker 2 The Impact of Safety on Florida Agriculture Florida

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

Quality Control Checklist - Design Drawings

Quality Control Checklist - Design Drawings Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Licensed Electricians Practical Assessment (LEP)

Licensed Electricians Practical Assessment (LEP) Licensed Electricians Practical Assessment (LEP) Surname: Given Names: Date: Time: Location: Assessment Time (includes reading and preparation time): At the end of this time you will be asked to stop.

More information

SIMpull THHN, it slips and slides - all with NoLube.

SIMpull THHN, it slips and slides - all with NoLube. SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Residential Construction Checklist Single and Two Family Construction

Residential Construction Checklist Single and Two Family Construction DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy

More information

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Chapter 6. WIRING SYSTEMS Safe Electrical Design Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

SECTION BUILDING WIRE AND CABLE

SECTION BUILDING WIRE AND CABLE SECTION 260519 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Building wire and cable. 2. Wiring connectors and connections. B. RELATED SECTIONS 1. Section 26 05 53 Electrical Identification. 2. Section

More information

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians. Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians. The following test is for Continuing Education Credits for the abovementioned

More information

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER GROUNDED ELECTRICAL POWER DISTRIBUTION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER .0 Conductors for Electrical Power Distribution For single-phase transmission of AC power or

More information

Busbar and Modular Wiring Systems

Busbar and Modular Wiring Systems Chapter 11 Busbar and Modular Wiring Systems 11.1 BUSBAR SYSTEM The wide range of busbar system is available and can be used for single or three-phase distribution to many types of applications ranging

More information

Customer Connection Guide Updates Effective May 2017

Customer Connection Guide Updates Effective May 2017 This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services

More information

12.6 Delta Phase versus Line Current

12.6 Delta Phase versus Line Current Unit 12 Delta/Delta and Delta/Wye Transformers Electrical NEC Exam Preparation 12.6 Delta Phase versus Line Current Since each line conductor from a delta transformer is actually connected to two transformer

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Construction Electrician/Industrial Electrician/Power Electrician Common Core Level 2

Construction Electrician/Industrial Electrician/Power Electrician Common Core Level 2 Common Core Level 2 Unit: B1 Commercial Electrical Code Level: Two Duration: 60 hours Theory: Practical: 60 hours 0 hours Overview: This unit is designed to provide the apprentice with the knowledge about

More information

3Ø Short-Circuit Calculations

3Ø Short-Circuit Calculations 3Ø Short-Circuit Calculations Why Short-Circuit Calculations Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective

More information

ELPT 1429 RESIDENTIAL WIRING

ELPT 1429 RESIDENTIAL WIRING SYLLABUS ELPT 1429 RESIDENTIAL WIRING INDUSTRIAL AND COMMERCIAL ELECTRICITY BRAZOSPORT COLLEGE LAKE JACKSON TEXAS PREPARED BY: Larry Grable DATE: September 13, 2005 INSTRUCTOR RECOMMENDED BY: RECOMMENDED

More information

Licensed Electricians Practical Assessment (LEP)

Licensed Electricians Practical Assessment (LEP) Licensed Electricians Practical Assessment (LEP) Surname: Date: Given Names: Time: Assessment Time (includes 10 minutes reading time): At the end of this time you will be asked to stop. 4 hours Have you

More information

Grounding and Bonding

Grounding and Bonding Grounding and Bonding 2017 Communications Academy Joe Blaschka Jr., PE Grounding/Bonding What is it? Why do we do it? What does the National Electrical Code say? What about fixed locations? What about

More information

Wiring Techniques for Wiring a Lamp

Wiring Techniques for Wiring a Lamp Supplies and Tools that you will need: Provided in your kit: Polarized lamp plug, 9 of SPT-1 18 AWG parallel lamp cord, bushings and grommets Items that you will need to provide: Phillips screwdriver,

More information

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1 GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Section N Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1 N. CONNECTION WITH CERTAIN FACILITIES AND/OR EQUIPMENT

More information

Customer Requirements RF Antenna Installations

Customer Requirements RF Antenna Installations Application Terms Attachment requirements and clearances on the Pole for Radio Frequency (RF) antenna equipment installations. This standard is intended to allow electrical workers to perform their normal

More information

POWER SERVICE DETAILS

POWER SERVICE DETAILS POWER SOURCE # POLE MOUNTED SERVICE TRANSFORMER BY POWER HANDHOLE 0/0V, -PHASE, SERVICE CONDUCTORS; -# AWG SERVICE CONDUCTOR AND -# AWG GROUNDED SERVICE CONDUCTOR (NEUTRAL) SERVICE XFMR SECONDARY. A 0V

More information

SECTION EQUIPMENT WIRING

SECTION EQUIPMENT WIRING PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 26 27 17 EQUIPMENT WIRING A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General Provisions,

More information

Electrical Occupations

Electrical Occupations Job Ready Assessment Blueprint Electrical Occupations Test Code: 3029 / Version: 01 Copyright 2011. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information

More information

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

FTTH ENGINEERING AND INSTALLATION INTRODUCTION 1 FTTH ENGINEERING AND INSTALLATION INTRODUCTION GROUNDING FTTH SYSTEMS AT THE HOME. By Dean Mischke, P.E., V.P. Grounding and bonding. Why are we worried about such an old school concept in the modern

More information

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes FINAL - ER 70 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions.

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 16 FROM:

More information

Installation requirements

Installation requirements Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and

More information

Table of Contents. (cont d) User's Guide 1

Table of Contents. (cont d) User's Guide 1 Table of Contents ELECTRICALC PRO...3 GETTING STARTED...4 KEY DEFINITIONS...4 Basic Function Keys...4 Mode Set-up Keys...5 Electrical Keys...6 Motor Keys...8 Wire Sizing Keys...9 Voltage Drop Keys... 11

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

Applying the NEC to Amateur Radio. By Tim Kuhlman, PE

Applying the NEC to Amateur Radio. By Tim Kuhlman, PE Applying the NEC to Amateur Radio By Tim Kuhlman, PE KD7RUS Purpose of this Course Detail Review of the National Electrical Code as it Applies to Amateur Radio Overview of the NEC Structure Define Article

More information

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118 PART 1: GENERAL This section of the design standard outlines general requirements for electrical and telecommunications designs to be performed for the University of Texas at Austin. This standard is intended

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION-16075 ELECTRICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Electrical identification to identify all electrical items for easy operation and maintenance including, but not limited

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as

More information

SECTION COMMUNICATIONS COPPER OSP CABLING

SECTION COMMUNICATIONS COPPER OSP CABLING SECTION 27 13 14 COMMUNICATIONS COPPER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,

More information

Grounding and Bonding of Service Equipment

Grounding and Bonding of Service Equipment Grounding and Bonding of Service Equipment 1. Grounding means: attached to an earth ground. 2. Bonding means: physically connected to insure electrical continuity. NEC 250.4 1. Grounding: Electrical Systems

More information

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems UNITY/I TM UT3K, UT4K, UT5K and UT8K Single-Phase Uninterruptible Power Systems Installation Manual MLS-0351C-OL Copyright 1994-1997 Best Power. All rights reserved. å IMPORTANT SAFETY INSTRUCTIONS! SAVE

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA) ER 87 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The

More information

Bulletin Voltage drop in single dwelling units Rule 8-102

Bulletin Voltage drop in single dwelling units Rule 8-102 Bulletin 8-6-0 Voltage drop in single dwelling units Rule 8-102 Scope Issued February 2014 (1) Background (2) Application of voltage drop for branch circuits in single dwelling units a) Determination of

More information

Alternating Current Power

Alternating Current Power Chapter 4 Alternating Current Power MElec-Ch4-1 Overview What is Alternating Current AC Hazards AC Power Requirements Shoreside Utility System On-Board Generators MElec-Ch4-2 What is Alternating Current

More information

Electrical Calc Elite

Electrical Calc Elite Electrical Calc Elite For ios The most up-to-date NEC compliant electrical calculator in the world. CyberProdigy LLC The Electrical Calc Elite is designed with electricians in mind to solve the most common

More information

Cable Hanging Instruction Manual

Cable Hanging Instruction Manual Tri-States Grain Conditioning, Inc. Cable Hanging Instruction Manual There are several types of grain storage tanks and bins. Parts of these instructions may be modified to fit the circumstances. Care

More information

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

IC800SSD Hardware Manual Pub 348R5. for models. A publication of IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011 NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by

More information

Bulletin Voltage drop in single dwelling units Rule 8-102

Bulletin Voltage drop in single dwelling units Rule 8-102 Bulletin 8-6-1 Voltage drop in single dwelling units Rule 8-102 Issued April 2014 Supersedes Bulletin 8-6-0 Scope (1) Background (2) Application of voltage drop for branch circuits in single dwelling units

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

6B.6 Substation Grounding

6B.6 Substation Grounding 1 No v 1 6 1 No v 1 6 Iu d a Mo r a r a n d ma n a g e r R a c h e le Ha n n o n Vo l.6 -S u b s ta tio n a n d Hig h Vo lta g e E q u ip me n t;p a r tb -S u b s ta tio n Co n fig u r a tio n s 1. Scope

More information

Message from the President

Message from the President Message from the President SEPTEMBER 2014 We find ourselves saying farewell to a fantastic spring and summer season and welcoming the fall s seasonal activities. We are planning some timely and informative

More information