Supplemental Motor Protection Devices Table of Contents
|
|
- Gerard Griffin
- 5 years ago
- Views:
Transcription
1 Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page - Bulletin 0 Motor Winding Heater: Automatic Operation, Solid-State Design... Page - Bulletin S Line Voltage and Current Monitor Relays... Web NOTE: Information for this product line is available on the Industrial Controls Catalog web site: 0 -
2 Bulletin 0S/S// Product Overview MachineAlert Relays The MachineAlert Relays family of dedicated function electronic motor protection relays offers state-of-the-art supplementary protective functions that are easily added and applied to motor control circuits. MachineAlert Relays are an economical choice for protecting equipment investments and minimizing production downtime. To meet specific application requirements, a full range of products allows selective addition of protective enhancing functions for both motors and equipment. Current monitors Phase monitors Thermistor monitors Rotation monitors Table of Contents Product Overview... this page Product Selection... - Specifications... - Approximate Dimensions... - Standards Compliance Bulletins 0S/S/ EN 0-, EN0 CSA C., No. UL 0 Product Overview Description Certifications Bulletins 0S/S/ culus Listed (File E0, Guide NKCR, NKCR) Electronic Design Microprocessor technology provides highly accurate and repeatable protection Built-in LCD and keypad afford a precise, digital setting Wide adjustment ranges allow for application flexibility Password protection hinders unauthorized programming access Compact. mm and mm packaging Global application with CE and culus approvals Enhanced Protection Current monitors that provide the added benefits of under- and overcurrent detection Phase monitors that guard against the damaging effects of phase loss, under- and overvoltage, phase imbalance, and phase reversal Thermistor monitors that protect equipment from overtemperature conditions Motor rotation monitors that signal motor rotational status Standards Compliance Bulletin IEC -, IEC - IEC -, IEC SEV, SEN 0 CSA C., No. UL 0 Certifications Bulletin curus Recognized (File, Guide NKCR, NKCR) SEV NEMKO FI Easy to Use Compact size saves valuable panel space LCD/keypad programming takes the guesswork out of device setup DIN Rail mounting makes installation a snap Terminals provide IP0 finger safety protection and are clearly marked LCD display provides relay status indication 0 Bulletin 0S Current Monitors undercurrent, overcurrent, current imbalance, phase loss, phase sequence Bulletin S Phase Monitors phase loss, under/overvoltage, phase imbalance, phase sequence Bulletin Thermistor Monitors overtemperature Features Three versions available Programmable relay trip and reset level settings Programmable relay trip and reset delay settings Automatic reset Three-phase version includes current imbalance and phase loss and phase sequence monitoring Independent programmable trip settings for undervoltage, overvoltage, and phase imbalance Programmable relay trip and reset delay settings RMS voltage monitoring up-to 0V AC Pre-start as well as running protection Automatic reset N.O. and changeover contact Two versions available Connection of up-to six PTC thermistors in series Open and short circuit detection Short circuit protected signal input Automatic, manual and remote reset options available Status indication LEDs Typical Applications Conveyors Cutting and drilling machines Pumps Mixers Pumps Fans Blowers Compressors VFD Controlled Motors Transformers Bearings Heating systems Bulletin Motor Rotation Monitors zero speed detection Zero speed monitoring through evaluation of the feedback voltage of a decelerating motor Standstill monitoring by means of a pulse generator, tachometer, etc. Frequency monitoring for signals of any curve form in the range of 00V p-p Programmable relay trip and reset settings Programmable time delay settings Conveyors Centrifuges Band saws Grinders -
3 Bulletin 0S/S// Product Family Overview/Product Selection Product Family Overview Bulletin 0S Current Monitors Bulletin S Phase Monitors Bulletin Thermistor Monitors Bulletin Motor Rotation Monitors Features E E E E E E E Under- and overcurrent protection S S Under- and overvoltage protection S S Phase imbalance and phase loss protection voltage based Phase sequence protection S Overtemperature protection S S Speed detection via frequency input S Speed detection evaluation of motor feedback voltage S S Operating Range 0. A.0.V 0 V.0.0 A 00V AC or 0V AC IEC 00V AC CSA/UL 00V AC IEC 0V AC CSA/UL 00V AC Case size (mm).... LCD / keypad S S S S S LED Status Indicator S S Automatic reset S S S S O S S Manual reset O Remote reset O Changeover contacts (SPDT) N.O. contacts (independent) (independent) No setting required S S Programmable trip level, reset level and time delay settings S S S S S Trip cause identification S S S Measuring Circuit Monitoring (open, short) S S S S S= Standard O= Option Product Selection Motor Protection Relay Type Description Cat. No. Bulletin 0S Current Monitors Bulletin S Phase Monitors Bulletin Thermistor Monitors Bulletin Motor Speed Monitors Rated supply voltage of 0V AC/DC. 0. A AC/DC (-phase),.0.v or 0 V AC/DC 0/0 Hz.0 A AC/DC (-phase) Monitoring Range 0 00V AC Monitoring Range 0 0V AC Automatic Reset Automatic, manual or remote reset, status storage Supply Voltage Suffix Code The Cat. No. as listed is incomplete. Select a Supply Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 0S-E becomes 0S-ED. Voltage Rating V DC V AC 0V AC ZJ D A Max. Monitored Voltage 00V AC max. (IEC), 00V AC max. (CSA/UL), or Frequency Monitoring for signals of any curve form in the range 00V p-p Max. Monitored Voltage 0V AC max. (IEC), 00V AC max. (CSA/UL) 0S-E 0S-E S-EB S-EC -E -E -E -E Frequency Code The Cat. No. as listed is incomplete. Select a Frequency Code from the table below to complete the Cat. No. Example: Cat. No. S-EBD becomes S-EBD0. Frequency Rating 0 Hz 0 Hz
4 Bulletin 0S/S// Specifications Current Transformers Use only with Cat Nos. 0S-E, 0S-E. Trip Current Range Continuous AC Amperes ( A Secondary Winding) Specifications Continuous Maximum Current [A] Inrush Cat. No S-CT S-CT S-CT S-CT Setting Programmable Settings Recommended Adjustment Range 0S-E Actuation Value, Current 0..0 A Release Value, Current 0..0 A Actuation Value, Voltage.0.V/0 V Release Value, Voltage.0.V/0 V Delay 0.0. s 0S-E Actuation Value, Imbalance % Release Value, Imbalance % Delay, Relay Energize 0.0. s Delay, Relay De-energize 0.0. s S-E Overvoltage Level (EB/EC) 0 00V AC/0 00V AC Undervoltage Level (EB/EC) 0 00V AC/0 00V AC % Imbalance Level % Delay, Relay Energize 0.0. s Delay, Relay De-energize 0.0. s -E Actuation Value, Voltage.0.V AC Release Value, Voltage.0.V AC Actuation Value, Frequency 0 Hz Release Value, Frequency 0 Hz Delay 0.0. s -E Actuation Value, Voltage.0.V AC Release Value, Voltage.0.V AC Delay, Relay Energize 0.0. s Delay, Relay De-energize 0.0. s Bulletin PTC Sensor Characteristics Type of control unit Mark A Sensor Characteristic per IEC -- Maximum number of sensors Maximum cold resistance of PTC sensor chain 00 Ω Trip resistance 00 Ω (±00 Ω) Reset resistance 0 Ω (±0 Ω) Short circuit trip resistance <0 Ω ( Ω, +0 Ω) Short circuit reset resistance Ω ( 0 Ω, + Ω) Open circuit resistance >000 Ω Bulletin Power/Trip Idendification Power on Green Trip Overtemperature Red Trip open circuit (Sensor) Red Hz Trip short circuit (sensor) Red flashes Bulletin Measuring and Reset Lines Up to 00 parallel or twisted; Measuring Line >00 m shielded, shield connected with T Minimum Cross Section (mm) Maximum Line length (m) Max 00 m; Remote reset Up to 00 parallel or twisted; >00 m shielded, shield connected with r Bulletin Relay Configuration -E -E 0 Normal Tripped Power Off -
5 Bulletin 0S/S// Specifications, Continued Dedicated Function Relays, 0S-E to S-E Dedicated Function Relays 0S-E 0S-E S-E ELECTRICAL Main Rated Insulation Voltage (U i ) 0V AC 0V AC 0V AC Rated Operating Voltage (U e ) Measurement Range IEC: 0V AC CSA/UL: 0V AC 0... A AC/DC.V 0...V AC/DC IEC: 0V AC CSA/UL: 00V AC... A AC/DC IEC: 0V AC CSA/UL: 00V AC EB: 00V EC: 0V Accuracy ±% ±% ±% Number of Phases Supply Rated Supply Voltage (U s ) Operating Range V DC V AC, 0V AC AC: 0.. U s DC: 0.. U s V DC V AC, 0V AC AC: 0.. U s DC: 0.. U s V DC V AC, 0V AC AC: 0.. U s DC: 0.. U s Maximum Power Consumption VA VA VA Output Relay Type of Contacts Rated Operating Current () Form C 0V AC V DC () Form A () Form C 0V AC V DC () Form A () Form C 0V AC V DC Utilization Category AC, DC AC, DC AC, DC MECHANICAL Environmental Ambient Temperature Humidity (storage) 0 +0 C 0 +0 C 0 +0 C (operating) +0 C +0 C +0 C % non-condensing % non-condensing % non-condensing Maximum Altitude 000 m 000 m 000 m Pollution Environment Pollution Degree Pollution Degree Pollution Degree Degree of Protection IP0 IP0 IP0 Terminal Cross-Sections Terminal Screws M M M Conductor Size 0.. mm AWG 0.. mm AWG 0.. mm AWG 0 -
6 Bulletin 0S/S// Specifications, Continued Dedicated Function Relays, -E to -E Dedicated Function Relays -E -E -E -E ELECTRICAL Main Rated Insulation Voltage (U i ) 0V AC 0V AC 00V AC 0V AC Rated Operating Voltage (U e ) IEC: 0V AC CSA/UL: 0V AC IEC: 0V AC CSA/UL: 0V AC IEC: 00V AC CSA/UL: 00V AC IEC: 0V AC CSA/UL: 00V AC Measurement Range Freq: 0 Hz ( 00V p-p ) Back-EMF:.0.V Back-EMF:.0.V Accuracy ±% ±% Number of Phases Supply Rated Supply Voltage (U s ) 0V AC/DC 0V AC/DC V DC, V AC, 0V AC V DC, V AC, 0V AC Operating Range 0.. U s 0.. U s AC: 0.. U s DC: 0.. U s AC: 0.. U s DC: 0.. U s Maximum Power Consumption. VA. VA VA VA Output Relay Type of Contacts Rated Operating Current () Form A dependent 0V AC. 0V AC () Form A independent 0V AC. 0V AC () Form A independent 0V AC V DC () Form A () Form C 0V AC V DC Utilization Category AC, DC AC, DC AC, DC AC, DC MECHANICAL Environmental Ambient Temperature Humidity (storage) 0 +0 C 0 +0 C 0 +0 C 0 +0 C (operating) +0 C +0 C +0 C +0 C % non-condensing % non-condensing % non-condensing % non-condensing Maximum Altitude 000 m 000 m 000 m 000 m Pollution Environment Pollution Degree Pollution Degree Pollution Degree Pollution Degree Degree of Protection IP0 IP0 IP0 IP0 Terminal Cross-Sections Terminal Screws M M Conductor Size 0.. mm 0 AWG 0.. mm 0 AWG 0.. mm AWG 0.. mm AWG 0 -
7 Bulletin 0S/S// Approximate Dimensions Approximate Dimensions Dimensions shown are in millimeters (inches) Dimensions are not intended for manufacturing purposes. 0S-E, -E 0S-E, S-E, -E 0 -
8 Bulletin 0S/S// Approximate Dimensions, Continued Dimensions shown are in millimeters (inches) Dimensions are not intended for manufacturing purposes. -E, -E 0S-CT, 0S-CT, 0S-CT, 0S-CT Use only with Cat. Nos. 0S-E and 0S-E Cat. No. 0S-CT 0S-CT (-/) 0S-CT 0S-CT A Min. B C D E F (-/). (-/) 0 () (-/) (-/) (-/) (-/) (-/). (-/) () (-/) (-/) (-/). (-/). (/). (/). (/) 0 -
9 Function and Wiring Diagrams 0S-E Wiring Diagram Bulletin 0S/S// 0S-E Wiring Diagram Function and Wiring Diagrams 0S-E Function Diagram 0S-E Function Diagram 0 -
10 Bulletin 0S/S// Function and Wiring Diagrams S-E Wiring Diagram S-E Function Diagram 0-0
11 -E Wiring Diagram Bulletin 0S/S// -E Wiring Diagram Function and Wiring Diagrams, Continued -E Function Diagram -E Function Diagram 0 -
12 Bulletin 0 Arcing Ground Fault Detection System Overview Arcing Ground Fault Relay Cat. No. 0-DOBD Arcing Ground Fault Sensor Cat. No. 0-N Bulletin 0 Arcing Ground Fault Detection System Adjustable trip from A for maximum sensitivity without nuisance tripping Output Form C contact (single-pole double-throw) for application flexibility Time delay of 0 ms nominal to minimize nuisance tripping and allow time for high current inhibit Test circuit is built into test system for proper operation Table of Contents Product Selection... - Specifications... - Typical Wiring Diagrams... - Approximate Dimensions... - Standards Compliance CSA C., No. UL 0 Certifications CSA Certified (LR0) UL Listed (File E, Guide KDAX) The Bulletin 0 Arcing Ground Fault Detection Systems are intended for equipment protection only. These systems are not Ground-Fault Circuit-Interrupters for personnel protection as defined in Article 00 of the U.S. National Electric Code. Bulletin 0 is available in two designs, Class I and Class II. The Class I systems are intended for use with shunt-trip circuit breakers or medium voltage controllers. These Class I systems do not contain a high-current inhibit circuit. The Class II Systems are designed for use with motor starters or contactors to interrupt low-level ground faults. They incorporate a highcurrent inhibit circuit that guards against the controller opening when the fault current exceeds the controller interrupting capacity. Ground fault currents exceeding the interrupting rating of the controllers are designed to be cleared by the short circuit protection device (fuse or circuit breaker). Both Class I and Class II Systems consist of two parts a relay and a sensor. The relay contains all the detection, adjustment and output circuitry. The sensor is a special two-winding current transformer. Operation of the ground fault detection system is indicated by the relay toggle. 0 -
13 Bulletin 0 Arcing Ground Fault Detection System Product Selection Product Selection Arcing Ground Fault Relays Class II with High Current Inhibit Feature NEMA Starter Size Arcing Ground Fault Sensors Maximum Maximum High Current Inhibit [A] Voltage [V AC] Horsepower [Hp] Full Load Current [A] Min. Max. Cat. No BOAD BOBD BOCD COAD 0 0-COBD 0-COCD DOAD DOBD 0 0-DOCD EOAD EOBD 00 0-EOCD FOAD FOBD FOCD GOAD GOBD 00 0-GOCD NEMA Starter Size Max. Recommended Cable Size Window Diameter Cat. No. 00V AC -/ in. 0-N 0 00V AC 000V AC 000V AC 00 00V AC 0 000V AC 0 000V AC V AC V AC V AC For a -phase system with one cable per phase except as indicated. 000V cable select sensor to have a window diameter greater than. times the cable diameter. Arcing Ground Fault Relays Class I without High Current Inhibit Feature -/ in. 0-N -/ in. 0-N -/ in. 0-N Application Max. Line Voltage [V] Cat. No. Shunt-Trip Circuit Breaker 00 0-MV Medium Voltage Controller 00 Note: Interrupting capacity is determined by starter or circuit breaker selection. 0 -
14 Bulletin 0 Arcing Ground Fault Detection System Specifications 0 Wiring diagrams are shown in the tripped condition. -
15 Bulletin 0 Arcing Ground Fault Detection System Approximate DimensionsText Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Arcing Ground Fault Relay Arcing Ground Fault Sensors Cat. No. 0-N:. (/) x. dia. (/) Cat. No. 0-N:. (/) x. dia. (/) Cat. No. A B C D E F G H J K 0-N 0-N 0-N 0-N. (-/). (-/). (-/). (-/). (-/). (-/) (-/). (-/) 0 (-/). (-/). (-/). (-/) (-/) (-/). (-/). (-/). (-/). (-/). (-/). (-/). (-/). (-/). (-/). (-/). (-/) 0. (-/). (-/). (-/) Cat. No. 0-N Cat. No. 0-N. (-/). (-/). (-/) 0 (-/). (-/). (-/) 0 -
16 Bulletin 0 Motor Winding Heater Overview/Product Selection/Connection Diagram/Specifications Motor Winding Heater Product Selection -Phase Motor Voltage, +0%, -%, 0 Hz -Phase Hp Rating Cat. No EOA EOB EOC FOA FOB FOC GOA GOB GOC HOA HOB HOC For applications requiring different horsepower, kilowatt, and voltage ranges from those listed, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Connection Diagram See Applicable Codes and Laws. Bulletin 0 Motor Winding Heater Solid-state design Automatic operation No adjustments required Bulletin 0 Motor Winding Heater is intended for use with -phase AC motors to guard against damage caused by condensation build-up on motor windings, which can occur in high-humidity environments during motor off times. This device is not intended to be used to dry out damp motors. Bulletin 0 Motor Winding Heater is designed for used with -phase AC squirrel-cage motors controlled by automatic full-voltage starters. For applications involving reduced-voltage starters, multi-speed starters, synchronous motors, or the used of power factor correction capacitors, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Specifications Output Voltage Regulation Ambient Temperature Range Additional SCR Protection True RMS Output Current Power Delivered to the Motor Standards Compliance CSA C., No. UL 0 Certifications CSA Certified (LR ) UL Listed (File E, Guide NMTR) Voltage applied to motor winding will vary ±% maximum for line voltage variations of +0%, %. Operating 0 0 C ( F) Storage + C ( + F) Metal oxide varistor protects against voltage surges. RC snubber circuit limits rate of change of circuit voltage. Approximately % of full load current. Approximately W/Hp. Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes 0 Cat. No. A B C 0-EOA... 0-EOB0 (-/) (-/) (-/) 0-EOC0 0-FOA0 0-FOB 0-FOC 0-GOA 0-GOB 0-GOC 0-HOA 0-HOB 0-HOC 0. (-/). (-/). () 0 (-/). (-/). (-/). () 0. (-/) 0. (-/) -
Supplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation
More informationSupplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationDeploying Current Transformers in Applications Greater Than 200 A
Deploying Current Transformers in Applications Greater Than 200 A Andrew Schaeffler Step-down Current Transformers (CTs) are common, and useful, in large motor applications. They provide isolation between
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationRCMS460 and RCMS490 Series
4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationSoftstarters. Specification guide. Type PST. Low Voltage Products & Systems
Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationBulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide
Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................
More informationFeatures. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.
Measuring and Monitoring Relays K8AB Series Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions. Single-phase
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationStarting Torque Controller Technical Data
Technical Data Starting Torque Controller Technical Data Bulletin 154 Topic Page Product Overview 2 Catalog Number Explanation 2 Product Selection 3 Specifications 3 Wiring Diagrams 9 Approximate Dimensions
More informationIndustrial Controls. Catalog IC SIRIUS. Answers for industry.
Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationSolid-state Contactor Specifications
Technical Data Solid-state Contactor Specifications Bulletin Number 156 Topic Page Topic Page Catalog Number Explanation 2 Dual- and Three-phase Devices 25 Single-phase Devices 3 Product Selection 25 Product
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationNEMA Contactor and Starter Specifications
Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationCI-tronic Soft start motor controller
Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationElectronic relays. Monitoring. Monitoring
Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationS11 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More informationAF91 Adjustable Frequency Drives Series B
Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based
More informationSingle, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N
Bulletin Product Overview/Catalog Number Explanation Cat. No. -B-HXJX--N Control Circuit Transformer, - pole with Optional Cat. No. -R Fuse Cover Cat. No. -C-BASX--N Control Circuit Transformer, Non-Fused
More informationPTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device
MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor
More informationAC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10
Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge
More informationBulletin 1497 Global Control Transformers
Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Circuit Transformers Bulletin 1497 Global Control Circuit Transformers are designed to reduce supply voltages to control circuits.
More informationSELECTION GUIDE. BULLETIN 156 Solid-State Contactors
SELECTION GUIDE BULLETIN 156 Product Overview/Product Selection Bulletin 156 The Bulletin 156 are ideal replacements for electro-mechanical contactors where fast and demanding switching of loads such
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationEN 50178, IEC
Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230
More informationIPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection
IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.
More information650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN
650 PHOENIX CONTACT Monitoring relays, timer relays, function blocks The requirements pertaining to safety and system availability are constantly increasing regardless of the industry. Processes are becoming
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations
More informationReferences 1 for asynchronous motors 1
References 1 DF56902 DF5690 DF56901 ATS 01N10FT ATS 01N212QN ATS 01N20LY for 0.7 to kw motors power Nominal current Reference (2) Weight Single phase -phase 20 V 210 V 20 V 20 V 400 V 460 V kw HP kw HP
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationFor additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:
Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationModel Number Structure
Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported
More informationUser's Guide. AC Circuit Load Tester. Model CT70
User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor
More informationInstructions for D64RPB30 Series C1 Ground Fault Relay
Instructions for D64RPB30 Series C1 Ground Fault Relay Cat. No. D64RPB30 CT 24-240V AC / DC N.C. N.O. 1 2 3 4 5 6 7 8 ON F2024-01-01 FLASHES: 1 = E/F 2 = S/C 3 = BACKUP 4 = CT 5 = F/S CV LOSS CONT = TRIP
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content
ABB Measuring and monitoring relays CM and C5xx range Content Benefits and advantages, overview of features... 60 Approvals and marks... 64 Current and voltage monitors, single-phase... 65 Ordering details...
More informationCircuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A
SNO 4062K Basic unit for emergency stop and guard door applications Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring. PL e and category 4 as per
More informationPhase-sequence Phase-loss Relay
Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationProtection components
Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationSECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)
ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX
More informationTAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz
TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase
More informationBulletin 700-RTC Solid-State Timing Relay
Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,
More informationTime relays. Monitoring relays /
61 2007 Time relays /2008 Monitoring relays 62 Automation is our passion For dozens of years now, Relpol S.A. has been a worldwide known supplier of components used in industrial and power automation,
More informationSECTION AUTOMATIC TRANSFER SWITCH
SECTION 26 36 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, withstand and close-on ratings as shown on the plans.
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationEMI Installation Guidelines
EMI Installation Guidelines Although Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Interference (EMI), proper installation and wiring methods must be followed
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationDescription Basic devices with positive operation contacts
Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with
More informationContactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en
Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors
More informationCurrent monitor Type C 551
Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More information