Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en
|
|
- Georgia Harris
- 6 years ago
- Views:
Transcription
1 Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en
2 Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors Schaltbau offers a scalable solution for handling direct current loads in the range of 0 A to 0 A for the most common coil voltages up to 0 V. When utilizing a contactor its coil is powered by a battery and a magnetic field is generated around its armature by the direct current voltage coming from the battery. That is why Schaltbau battery contactors feature extra wide coil tolerance. They have double-break contacts, are compact in size, economical in price, and known for their reliability. Version»C«are single-pole NO contactors with magnetic blowout, whereas version»h«are single-pole change-over contactors which feature an additional, electrically seperated contact element. This extra normally closed contact is, however, without blowout magnets and not designed to make and break current. Bistable versions: C6 Series contactors are also available with magnetic latching. The change towards one of the two bistable positions of the main contact is operated by a pulse of 00 msec. duration. The coil consumes no power except for the short pulse necessary to close and reopen the main contact, see also catalogue B6en. Features Applications Rugged, compact design Four different sizes Double breaking main contacts Extra wide coil tolerance for industrial and railway applications in accordance with VDE and UIC standards General purpose motor control contactor Starting lift/lower controls as well as speed and directional controls of industrial trucks Heater and air conditioning control of electric locomotives and multiple units Battery powered electric functions in passenger coaches Deep discharge protection for batteries of uninter- ruptible power supplies (UPS) Standards Meet requirements for industrial applications to: IEC 97- Low-voltage switchgear and controlgear - Part : General rules IEC 97-- Low-voltage switchgear and controlgear - Part -: Contactors and motor starters - Electromechanical contactors and motor starters. DIN EN 75- Safety of industrial trucks - Electrical requirements - Part : General requirements for battery powered trucks Meet requirements for railway applications to: IEC 077- Railway applications - Electric equipment for rolling stock - Part : General service conditions and general rules. IEC 077- Railway applications - Electric equipment for rolling stock - Part : Electrotechnical components; General rules C7 and C6 Series contactors C6 and C65 Series contactors Subject to change
3 Ordering code C7 Series Example: C7 C/ EV-V C6 Series Example: C6 C/ EV-R Series C7 Single pole contactor Contact configuration Series C6 Contact configuration Single pole contactor C SPST NO * H SPDT * Coil voltage / 6 / 8 / 7 / 80 / 0 V DC Coil tolerance R -0 % +0 % U s E -0 % +5 % U s Coil suppression X none V varistor Aux. contacts, Configuration C SPST NO * H SPDT * Coil voltage / 6 / 8 / 7 / 80 / 0 V DC Coil tolerance R E Coil suppression -0 % +0 % U s -0 % +5 % U s X none V varistor Aux. contacts, Configuration V microswitch, SPDT * Aux. contacts, Number of R S80, SPDT * Aux. contacts, Number of x microswitch * x microswitch * Stock items: Stock items: SPST NO contactors C7 C/ RX C7 C/ EV C7 C/ 8RX C7 C/ 6EV C7 C/ 80RX C7 C/ 8EV C7 C/ 7EV C7 C/0EV SPDT contactors C7 H/ RX C7 H/ EV C7 H/ 80RX C7 H/0EV SPST NO contactors C6 C/ RX C6 C/ EV C6 C/ 8RX C6 C/ 6EV C6 C/ 80RX C6 C/ 8EV C6 C/ 7EV C6 C/0EV SPDT contactor C6 H/ RX C6 Series Example: C6 C/ EV-R C65 Series Example: C65 C/ EV-R Series C6 Single pole contactor Contact configuration Series C65 Single pole contactor Contact configuration C SPST NO * H SPDT * Coil voltage / 6 / 8 / 7 / 80 / 0 V DC Coil tolerance R -0 % +0 % U s E -0 % +5 % U s Coil suppression X none V varistor Aux. contact, Configuration C SPST NO * H SPDT * Coil voltage / 6 / 8 / 7 / 80 / 0 V DC Coil tolerance R -0 % +0 % U s E -0 % +5 % U s at 55 C (-0 % +5 % U s at 70 C) Coil suppression X none V varistor Aux. contacts, Configuration R S80, SPDT * Aux. contact, Number of R S80, SPDT * Aux. contacts, Number of x microswitch * x microswitch * Stock items: Stock items: SPST NO contactors C6 C/ RX C6 C/ EV C6 C/ 8RX C6 C/ 8EV C6 C/ 80RX C6 C/ 7EV C6 C/0EV SPDT contactors C6 H/ RX C6 H/ 8RX C6 H/ 80RX SPST NO contactors C65 C/ RX C65 C/ EV C65 C/ 8RX C65 C/ 8EV C65 C/ 80RX C65 C/ 7EV C65 C/0EV SPDT contactor C65 H/ RX Presented in this catalogue are only stock items which can be supplied in short delivery time. Types for AC operation are available on special order: Replace version C with B (= NO contactor without blowouts) and version H with G (= changeover contactor without blowouts. Special variant If you need a special variant feel free to contact us. Maybe the type of contactor you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minumum order quantities apply. Subject to change * Version C are NO contactors fitted with permanent magnets. The normally open (make) contact is designed to make and break current like an open style power relay. * Version H changeover contactors feature electrically separated potential carrying make and break contacts. Please note that here only the normally open (make) contact is capable of switching current loads, whereas the normally closed (break) contact is designed to carry current but not to make and break current. * One microswitch max., with silver plated contacts
4 Specifications for industrial applications Series C7..R C6..R C6..R C65..R Type of voltage DC, AC * Main contacts, Number of, Configuration x SPST-NO or x SPDT * Nominal voltage U n Rated insulation voltage U i Rated impulse withstand voltage U imp Pollution degree Overvoltage category 0 V 50 V.5 kv PD OV Conventional thermal current I th 50 A 00 A 0 A 0 A Making capacity, resistive, T = ms 0 A 800 A,000 A,000 A Breaking capacity, T < ms SPST-NO SPDT * 80 V DC: 00 A 80 V DC: 00 A 80 V DC: 00 A 80 V DC: 00 A 80 V DC: 500 A 80 V DC: 00 A 80 V DC:,500 A 80 V DC: 800 A Rated short-time withstand current I cw 800 A / 00 ms.000 A / 00 ms,500 A / 00 ms,500 A / 00 ms Switch-off, no reversing only in one direction Main contacts Contact material Main terminals / tightening torque NO: NC: AgSnO AgNi / Nm max. AgSnO AgNi / 6 Nm max. AgSnO AgNi / 6 Nm max. AgSnO AgNi M0 / 0 Nm max. Auxiliary contacts Number of / Configuration Switching capacities, T = 0 ms Terminals, x SPDT.5 A at V DC;.0 A at 8 V DC; 0.5 A at 80 V DC.0 x 0.5 mm x S80.5 A at V DC;.0 A at 8 V DC; 0.5 A at 80 V DC 6. x 0.8 mm Magnetic drive Coil voltage U s Coil tolerance Coil power dissipation at U s and T a = 0 C Coil suppression Coil terminals, V... 0 V DC -0 % % U s W x 0.8 mm V... 0 V DC -0 % % U s 8 W x 0.8 mm V... 0 V DC -0 % % U s 0 W x 0.8 mm V... 0 V DC -0 % % U s 7 W x 0.8 mm Degree of protection IP00 Mechanical endurance, operating cycles Electrical endurance, operating cycles Vibration / Shock (EN 67) Mounting position Temperature Ambient temperature T a Storage temperature NO > m NC > m > m > 00,000 (U n, I th, T < ms, cycle 6/min) Class B, Cat. : Hz / 5 g (0 msec., half sinus) Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards -5 C +50 C -0 C +85 C Weight 0 g g 550 g g 9 g...,050 g,900 g...,50 g * Types for AC applications available on special order: Replace version C with B (= NO contactor without blowout); and version H with G (= changeover contactor without blowout), see ordering code on page * Changeover contactor: Here only the normally open (make) contact is capable of switching current loads, whereas the normally closed (break) contact is not designed to make and break current. Subject to change
5 5 Specifications for railway applications Series C7..E C6..E C6..E C65..E Type of voltage DC, AC * Main contacts, Number of, Configuration x SPST-NO or x SPDT * Nominal voltage U n Rated insulation voltage U i Rated impulse withstand voltage U imp Pollution degree Overvoltage category 0 V 50 V.5 kv PD OV Conventional thermal current I th NO: NC: 0 A 0 A 80 A A 0 A 0 A 0 A 0 A Making capacity, resistive, T = ms 00 A 0 A 800 A,500 A Breaking capacity, T < ms NO: Changeover:* 80 V DC: 50 A 80 V DC: A 80 V DC: 50 A 80 V DC: 50 A 80 V DC: 00 A 80 V DC: 50 A 80 V DC:,500 A 80 V DC: 800 A Rated short-time withstand current I cw 700 A / 00 ms 800 A / 00 ms.000 A / 00 ms.000 A / 00 ms Switch-off, no reversing only in one direction Main contacts Contact material Main terminals / tightening torque NO: NC: AgSnO AgNi / Nm max. AgSnO AgNi / 6 Nm max. AgSnO AgNi / 6 Nm max. AgSnO AgNi M0 / 0 Nm max. Auxiliary contacts Number of / Configuration Switching capacities, T = 0 ms Terminals, x SPDT.5 A at V DC;.0 A at 8 V DC; 0.5 A at 80 V DC.0 x 0.5 mm x S80.5 A at V DC;.0 A at 8 V DC; 0.5 A at 80 V DC 6. x 0.8 mm Magnetic drive Coil voltage U s Coil tolerance Coil power dissipation at U s and T a = 0 C Coil suppression Coil terminals, V... 0 V DC -0 % % U s 8 W Varistor 6. x 0.8 mm V... 0 V DC -0 % % U s W Varistor 6. x 0.8 mm V... 0 V DC -0 % % U s W Varistor 6. x 0.8 mm V... 0 V DC -0 % % U s * W Varistor 6. x 0.8 mm Degree of protection IP00 Mechanical endurance, operating cycles Electrical endurance, operating cycles Vibration / Shock (EN 67) Mounting position Temperature Ambient temperature T a Storage temperature NO > m NC > m > m > 00,000 (U n, I th, T < msec., cycle 6/min) Class B, Cat. : Hz / 5 g (0 msec., half sinus) Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards -5 C +70 C -0 C +85 C Weight 0 g g 550 g g 9 g...,050 g,900 g...,50 g * Types for AC applications available on special order: Replace version C with B (= NO contactor without blowout); and version H with G (= changeover contactor without blowout), see ordering code on page. * Changeover contactor: Here only the normally open (make) contact is capable of switching current loads, whereas the normally closed (break) contact is not designed to make and break current. * at -5 C C Subject to change
6 6 C7 SPST-NO or SPDT contactor Device outline: C7 Series SPST-NO contactor Circuit diagram C7 Series 8 ±0.5 0 ± ±0. 6 ±0. 85 ±0. 5 Ø.5 Ø.5 8 ±0.5 0 ± ± ±0. Ø ±0.5 0 ±0. 0 ±0..8x0.5.8x ± Circuit diagram VS-C7-x Tie bar HK-C7 Auxiliary contact C7 Series Outline: Tie bar VS-C7-7,5 Auxiliary contact assembly HK-C7 Ø7 Ø ± ±0. 6 ±0. 85 ± ±0. Ø.5 Device outline: C7 Series SPDT contactor 0 6. Ø.5 R7 8 ± ±0. Outline: Tie bar VS-C7-8, Ø7 R ±0. Screws M Torque Nm.8x0.5 Screws M Torque Nm Screws M Torque Nm.8x0.5 Screws M Torque Nm ± ± ± Fitted with varistor + and auxiliary contact, see ordering code on page. + Mounting: C7 Series contactors can be retrofitted with an auxiliary contact. + Loosen the M hex screw a little that connects the yoke to the magnet core. Slide slotted mounting bracket of auxiliary contact assembly under screw head. Push yoke against housing and retighten screw. + Fitted with varistor and auxiliary contact, see ordering code on page. Dimensions in mm / Subject to change
7 7 Characteristic curves Contact performance Dimensioning C7 Series Continuously rated, normally open contact Guide to permissible current rating 0 I th on name plate Short-time duty SPST-NO NO contact SPDT NC contact Overtemperature [K] Wire cross-section mm² 6 mm² Coil tolerance* R E R E R E 6 sec 50 A 80 A 50 A 80 A 00 A 0 A min 0 A 90 A 0 A 90 A 0 A 75 A min 00 A 70 A 00 A 70 A 90 A A 0 5 min 80 A A 80 A A 70 A 50 A 0 resulting from coil Conventional thermal current I th [A] 0 min 70 A 50 A 70 A 50 A A --- Above current ratings refer to wire cross-section 6 mm² * Coil voltage tolerance R: -0 % % U s E: -0 % % U s Continuously rated, normally closed contact Overtemperature [K] Wire cross-section mm² 6 mm² I th on name plate The thermal current rating for continuous duty is dependent on the upper limiting temperature of the contact elements which must not exceed 50 C. Wire gauge, ambient temperature, duty and operating cycles, contamination of contacts and contact wear are all factors that influence the surface temperature rise of the contact studs. All the above current ratings should, therefore, be considered as a guide only. The way you mount the contactor has no less an impact on the rise of temperature and the insulation of the switching device. So please observe the clearance between live or earthed parts and comply with the safety regulations of the applicable standards. No liability will be accepted by Schaltbau in any circumstances for indirect damage resulting from clearances not being observed, devices not mounted properly, or products tampered with in any way Conventional thermal current I th [A] Max. breaking capacity DC of NO contact for coil tolerance R and E 900 NO contactors version C Mounting position C7 Series Breaking current [A] Coil tolerance R % U s Coil tolerance E % U s E E R R L/R = 0 ms L/R = 5 ms L/R = 0 ms L/R = 5 ms Possible mounting orientations Horizontal Main contacts Mounting plate Vertical Switched voltage [V] The maximum breaking capacity is the value of prospective current at a stated DC voltage which can be ruptured by the contactor where the ensuing arc upon contact separation is still being quenched. For actual operation the current rating of the contactor should, therefore, be limited to 0 %... % of its maximum breaking capacity. Please note that for double throw contactors, in addition to the foregoing limitations, the switch off load of the normally open contact must be further reduced by 0 % to 50 %. Subject to change Mounting positions: Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards
8 .8x0.5 Screws.8x0.5 M Torque Nm C6 SPST-NO Ø.5or SPDT contactor Screws M Torque Nm Device outline: C6 Series SPST-NO contactor Ø ±0. 6 ±0. 5 ±0. 70 ± ± Circuit diagram + C6 Series 8 85 ±0. 85 ± ±0. Device outline: C6 Series SPDT contactor ±0. 0 ± 0 ± ±0. 85 ± ±0. 05 ± ± ±0. Ø Ø Fitted with varistor and auxiliary contact, see ordering code on page. + Circuit diagram 55 + VS-C6-x Tie bar HK-C6 Auxiliary contact C6 Series + 0 ±0. 5 Ø Ø Outline: Tie bar VS-C6-, Ø9.5.5 ± R Outline: Tie bar VS-C6-7,0 Mounting: Ø Ø9.5 C6 Series contactors can be Flat retrofitted tabs with an auxiliary contact. Loosen the M5 hex screw a little that connects the yoke to the magnet core. Slide slotted mounting bracket of auxiliary contact Ø ±0. assembly under screw head. Push yoke against housing and retighten 6 0 ±0. screw ±0. Dimensions in mm / Subject + to change R0 Auxiliary contact assembly HK-C6 + Fitted with varistor and auxiliary contact, see ordering code on page.
9 9 Characteristic curves Contact performance Dimensioning C6 Series Continuously rated, normally open contact Guide to permissible current rating 0 I th on name plate Short-time duty SPST-NO NO contact SPDT NC contact Overtemperature [K] Wire cross-section 6 mm² 5 mm² Coil tolerance* R E R E R E 6 sec 50 A 0 A 50 A 0 A 50 A 80 A min 00 A 50 A 00 A 50 A 50 A 0 A min 50 A 5 A 50 A 5 A 5 A 90 A 0 5 min 0 A 00 A 0 A 00 A 5 A 80 A 0 resulting from coil Conventional thermal current I th [A] 0 min 0 A A A 70 A Above current ratings refer to wire cross-section 6 mm² * Coil voltage tolerance R: -0 % % U s E: -0 % % U s Continuously rated, normally closed contact Overtemperature [K] Wire cross-section 6 mm² 5 mm² I th on name plate The thermal current rating for continuous duty is dependent on the upper limiting temperature of the contact elements which must not exceed 50 C. Wire gauge, ambient temperature, duty and operating cycles, contamination of contacts and contact wear are all factors that influence the surface temperature rise of the contact studs. All the above current ratings should, therefore, be considered as a guide only. The way you mount the contactor has no less an impact on the rise of temperature and the insulation of the switching device. So please observe the clearance between live or earthed parts and comply with the safety regulations of the applicable standards. No liability will be accepted by Schaltbau in any circumstances for indirect damage resulting from clearances not being observed, devices not mounted properly, or products tampered with in any way Conventional thermal current I th [A] Max. breaking capacity DC of NO contact for coil tolerance R and E 800 NO contactors version C Mounting position C6 Series Breaking current [A] Coil tolerance R % U s Coil tolerance E % U s E E R R L/R = 0 ms L/R = 5 ms L/R = 0 ms L/R = 5 ms Possible mounting orientations Horizontal Main contacts Mounting plate Vertical Switched voltage [V] The maximum breaking capacity is the value of prospective current at a stated DC voltage which can be ruptured by the contactor where the ensuing arc upon contact separation is still being quenched. For actual operation the current rating of the contactor should, therefore, be limited to 0 %... % of its maximum breaking capacity. Please note that for double throw contactors, in addition to the foregoing limitations, the switch off load of the normally open contact must be further reduced by 0 % to 50 %. Subject to change / Dimensions in mm Mounting positions: Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards
10 8 (DIN 6) Torque 6 Nm Ø Ø C6 SPST-NO or SPDT contactor (DIN 6) 0 C6 Series Device outline: C6 Series SPST-NO contactor Circuit diagram ±0. 0 ± (DIN 6) Torque 6 Nm Ø Ø Device outline: C6 Series SPDT contactor ±0. 0 ±0. (DIN 6) Torque 6 Nm Ø Ø ± ± ±0. ±0. (DIN 6) (DIN 6) Fitted with varistor and auxiliary contact, see ordering code on page ±0. ± Circuit diagram Fitted with varistor and auxiliary contact, see ordering code on page. VS-C6-x Tie bar HK-C6 Auxiliary contact C6 Series Ø9.5 R0 7 ± 7 ± ±0. ±0. Outline: Tie bar VS-C6-7, Auxiliary contact 97 + assembly HK-C (DIN 6) Outline: Tie bar VS-C6-56,0 Mounting: Ø9.5 C6 Series contactors can be retrofitted with an auxiliary contact. Loosen the M5 hex screw a little that connects the yoke to the magnet core. Slide slotted mounting bracket of auxiliary contact 56 ±0. assembly under screw head. Push yoke against housing and retighten Torque 6 Nm (DIN 6) Ø screw Ø Reduced scale diagrams / dimensions in mm Dimensions in mm / Subject to change ±0. ±0. R0 7 ± 7 ±0. ± ± ± M0 M0 +
11 Characteristic curves Contact performance Dimensioning C6 Series Continuously rated, normally open contact Guide to permissible current rating 0 I th on name plate Short-time duty SPST-NO NO contact SPDT NC contact Overtemperature [K] Wire cross-section 5 mm² 5 mm² Coil tolerance* R E R E R E 6 sec 800 A 650 A 800 A 650 A 00 A 0 A min 80 A 0 A 80 A 0 A 0 A 70 A min 0 A 70 A 0 A 70 A 70 A 50 A 0 5 min 90 A 55 A 90 A 55 A A resulting from coil Conventional thermal current I th [A] 0 min 70 A A A --- Above current ratings refer to wire cross-section 5 mm² * Coil voltage tolerance R: -0 % % U s E: -0 % % U s Continuously rated, normally closed contact Overtemperature [K] Wire cross-section 5 mm² 5 mm² I th on name plate The thermal current rating for continuous duty is dependent on the upper limiting temperature of the contact elements which must not exceed 50 C. Wire gauge, ambient temperature, duty and operating cycles, contamination of contacts and contact wear are all factors that influence the surface temperature rise of the contact studs. All the above current ratings should, therefore, be considered as a guide only. The way you mount the contactor has no less an impact on the rise of temperature and the insulation of the switching device. So please observe the clearance between live or earthed parts and comply with the safety regulations of the applicable standards. No liability will be accepted by Schaltbau in any circumstances for indirect damage resulting from clearances not being observed, devices not mounted properly, or products tampered with in any way Conventional thermal current I th [A] Max. breaking capacity DC of NO contact for coil tolerance R and E Breaking current [A] NO contactors version C Coil tolerance R % U s Coil tolerance E % U s L/R = 0 ms L/R = 5 ms Mounting position Possible mounting orientations Horizontal Mounting plate Vertical C6 Series Main contacts Switched voltage [V] The maximum breaking capacity is the value of prospective current at a stated DC voltage which can be ruptured by the contactor where the ensuing arc upon contact separation is still being quenched. For actual operation the current rating of the contactor should, therefore, be limited to 0 %... % of its maximum breaking capacity. Please note that for double throw contactors, in addition to the foregoing limitations, the switch off load of the normally open contact must be further reduced by 0 % to 50 %. Subject to change / Dimensions in mm Mounting positions: Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards
12 Ø C65 SPST-NO or SPDT contactor Ø (DIN 6) C65 Series Device outline: C65 Series SPST-NO contactor Circuit diagram ± ±0. 7 ± ± ±0. 0 ±0. (DIN 6) ± ± M0 M0 Fitted with varistor and auxiliary contact, see ordering code on page. Ø Ø ± Device outline: C65 Series SPDT contactor 97 + ±0. 7 ± 97 + ±0. M0 (DIN 6) Circuit diagram M ±0. 0 ±0. (DIN 6) ± ± M0 M0 M0 M0 Fitted with varistor and auxiliary contact, see ordering code on page. Ø Ø (DIN 6) VS-C65-x Tie bar HK-C65 Auxiliary contact C65 Series Outline: Tie bar VS-C65-,5 Ø R Auxiliary contact assembly HK-C ± Outline: Tie bar VS-C65-7,5 8 Ø 7.5 ± R Mounting: C65 Series contactors can be retrofitted with an auxiliary contact. Loosen the M5 hex screw a little that connects the yoke to the magnet core. Slide slotted mounting bracket of auxiliary contact assembly under screw head. Push yoke against housing and retighten screw. Dimensions in mm / Subject to change
13 Characteristic curves Contact performance Dimensioning C65 Series Continuously rated, normally open contact Guide to permissible current rating 0 I th on name plate Short-time duty SPST-NO NO contact SPDT NC contact Overtemperature [K] Wire cross-section 70 mm² 95 mm² Coil tolerance* R E R E R E 6 sec,500 A,00 A,500 A,00 A 650 A 50 A min 500 A 00 A 500 A 00 A 0 A 50 A min 00 A 0 A 00 A 0 A 70 A 0 A 0 5 min 50 A 80 A 50 A 80 A 50 A min 00 A 0 A 00 A 0 A 0 A --- resulting from coil Conventional thermal current I th [A] Above current ratings refer to wire cross-section 70 mm² * Coil voltage tolerance R: -0 % % U s E: -0 % % U s at 55 C / -0 % % U s at 70 C Continuously rated, normally closed contact Overtermperature [K] Wire cross-section 70 mm² 95 mm² I th on name plate The thermal current rating for continuous duty is dependent on the upper limiting temperature of the contact elements which must not exceed 50 C. Wire gauge, ambient temperature, duty and operating cycles, contamination of contacts and contact wear are all factors that influence the surface temperature rise of the contact studs. All the above current ratings should, therefore, be considered as a guide only. The way you mount the contactor has no less an impact on the rise of temperature and the insulation of the switching device. So please observe the clearance between live or earthed parts and comply with the safety regulations of the applicable standards. No liability will be accepted by Schaltbau in any circumstances for indirect damage resulting from clearances not being observed, devices not mounted properly, or products tampered with in any way Conventional thermal current I th [A] Max. breaking capacity DC of NO contact for coil tolerance R and E 000 NO contactors version C Mounting position C65 Series Breaking current [A] Coil tolerance R % U s Coil tolerance E % U s at 55 C or % U s at 70 C L/R = 0 ms L/R = 5 ms Possible mounting orientations Horizontal Mounting plate Vertical 00 Main contacts Switched voltage [V] The maximum breaking capacity is the value of prospective current at a stated DC voltage which can be ruptured by the contactor where the ensuing arc upon contact separation is still being quenched. For actual operation the current rating of the contactor should, therefore, be limited to 0 %... % of its maximum breaking capacity. Please note that for double throw contactors, in addition to the foregoing limitations, the switch off load of the normally open contact must be further reduced by 0 % to 50 %. Subject to change / Dimensions in mm Mounting positions: Horizontal: contact studs must point upwards or Vertical: plasma exits must point upwards
14 Notes Subject to change
15 5 Notes Subject to change
16 Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse Munich Germany Phone Fax Internet contact@schaltbau.de RoHS 0/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 008. Quality you can count on Schaltbau Certified to DIN EN ISO 00 since 00. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 900 since 99. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements B87/7/0 Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit Issued -07
B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.
Connect - Contact - Control Single pole cam contactors for DC and AC applications 10 7 120 M ED: % U 1,V Uiso. 0V 200A U 12V Art.:x-xxxx-xxxxxx Bj: xxwyy U 8,V 155 165 max. 60 B 80.en 2 Single pole C160/C162
More informationC20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control
Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!
More informationC20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control
Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!
More informationConnect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e
Connect - Contact - Control DC Contactors 600V / 750V / 1000V F 215e 2 Contents Application... 3 Technical Data... 3 Load Ratings... 3 Device Identification... 4 Coil Power Reduction... 5 Fire Rating...
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationConnect - Contact - Control. Connectors. Short Form Catalogue
Connect - Contact - Control Connectors Short Form Catalogue Components for electrical engineering Schaltbau connectors nowadays ensure good connections in all areas of electrical engineering. The product
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationThe CWC0 compact contactors are offered as a complete solution for switching and controlling motors.
Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationIGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards
APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More informationPluggable interface relays CR-U Universal relays
Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationRelay interface modules A
4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More information2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)
46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationDescription Basic devices with positive operation contacts
Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More informationHigh-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40
High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 C O M P O N E N T S The UR26, UR36 & UR40 are DC high-speed current limiting air Circuit-Breakers, trip free, single pole, bi-directional,
More informationElectronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different rated control supply voltages U S : DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationTransformers, Power Supply Units and Socket Outlets
Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationLC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -
More information48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12
48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More information40 Series - Miniature P.C.B. Relays A
..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient
More informationClassification Enclosure rating Contact form Contact material
PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm.
More informationLC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC2D09BL REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationLC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCOMPONENTS. Power contactor Type BMS09.08 / BMS18.08
COMPONENTS Power contactor Type 09.08 / 18.08 Type A (V AC General information The contactor, with more than hundred thousands units in operation worldwide, has always been a contactor valued by the car
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More informationmm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi
34 Series - Slim electromechanical PCB relays 6 A Features 34.51 Ultra-slim 1 Pole - 6 A relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw or screwless sockets 1 Pole
More informationThree-phase monitoring relay
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationRELOG. All-or-nothing Relay
RELOG All-or-nothing Relay Table of Content Page RELOG a system with contact components used in control engineering 3 Survey of the 'All-or-nothing relays' device program included in the RELOG system 3
More informationClassification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A
PCB Relay Low-profile power relay with maximum switching of 8 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm. RoHS
More informationInsulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC
Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More information38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationOrdering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A
PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10
More informationSafety Relay H-462. Dimensions LxWxH(in mm) Size 1: 57,8 x20,5 x48,6 Size 2: 67,4 x20,5 x48,6
General 4or 6 contacts Forced guided contact set According to EN 50205, application type A Ambient temperature 25 +80 C Soldering heat resistance 260 C/5s RoHS compliance Signal relay according to UIC
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationLow profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b
Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight
More informationStep relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control
Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationIndustrial Controls. Catalog IC SIRIUS. Answers for industry.
Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationElectronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationLC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil
Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationPower Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250
Power Electronics POWERSWITCH Semiconductor Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at
More informationKILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc
Product Facts Designed to be the smallest, lightest weight, lowest cost sealed contactor in the industry with its current rating (500+A carry, 2000A interrupt at 320VDC) Built-in coil economizer only 1.7W
More information