Electronic relays. Monitoring. Monitoring
|
|
- Augustus Terry
- 5 years ago
- Views:
Transcription
1 Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive downtimes. Consequently, electrical parameters such as voltage, current, phases, power factor (cos ϕ) and filling levels of conductive fluids should be monitored carefully and professionally. Series C x electronic monitoring relays from ABB are versatile. This extensive range offers various relays for detection and monitoring of electrical parameters such as current, voltage, phase imbalance, phase failure and phase sequence in single-phase or three-phase power systems and filling levels of conductive fluids. Thus, relays C 0 to C make it just as easy to protect installations and machines against overvoltage and undervoltage as they do to monitor currents in AC or DC power systems. Relays C 6 monitor overvoltage and undervoltage in -phase power systems with and without neutral conductor while units C and C 7 monitor phase failure, phase sequence and phase imbalance. Relay C 9 for power monitoring (cos ϕ) is used for control tasks on machines and to protect the machines against underload or overload. Level monitor C detects fluid levels of conductive fluids and can be converted to detection of falling or rising levels. Status LEDs indicate the circuit states of the units. Signalling is performed by one or two changeover contacts as an output protective circuit. All C x monitoring relays can be mounted quickly and in space-saving manner. With their overall width of 7.,. or mm, they offer performance and reliability while requiring minimum space. The ergonomic design of the operating controls allows easy and precise setting and the design and coloration of the monitoring units of Series C x match those of the entire range of ABB switchgear devices. The relays are mounted either on a mm DIN rail by snapping them on or with screws on a mounting plate. All units of the C x Series are rugged and designed for use in rough industrial atmospheres. The UL and CSA approvals permit worldwide use and all relays bear the CE mark. ABB Control Inc.. 8//00 Proof AC 0 9/00
2 Selection guide C0 C C.0 C.0 C C0 C C.0 C.0 C Current monitor Voltage monitor Voltage monitor Voltage monitor Voltage monitor Phase Single phase Single phase Single phase Single phase Single phase Range and frequency 0. V 00V 0 80V of the measuring signal 0A 00mA 0V 0 00V 6 60V 0 00Hz 0 00 Hz DC 6 60V V 0/60Hz DC 0 00 Hz DC 0 00 Hz DC Supply voltage tolerance +/- % with 0VAC/VDC VAC/VDC 0.8. Us 0.8. Us 0.8. Us resp VAC 0 7 VAC/VDC Max. power consumption VA 0 Permissible ambient temp operation F/ C - to +0/-0 to to +0/-0 to to +0/-0 to to +0/-0 to to +0/-0 to +60 storage F/ C - to +8/-0 to to +8/-0 to to +8/-0 to to +8/-0 to to +8/-0 to +70 Enclosure Housing IP IP IP IP IP Terminals IP 0 IP 0 IP 0 IP 0 IP 0 Width mm/inches 7./0.7./0.89./0.89./0.89./0.89 for relay output Contact arrangement N.O. SPDT SPDT SPDT SPDT Contact material AaCdO AaCdO AaCdO AaCdO AaCdO Maximum permissible Making/breaking capac. 0 VA 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w Max. switched current A VAC/VDC 8A VAC/ 0A VDC 8A VAC/ 0A VDC 8A VAC/ 0A VDC 8A VAC/ 0A VDC Min. switched current 0mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC Max. switched voltage 0VAC/VDC 80VAC 80VAC 80VAC 80VAC Electrical service life at 0 VA ohmic at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic Operations 00,000 00,000 00,000 00,000 00,000 Mechanical service life operations Insulation contact/coil kv kv kv kv kv Conductor connector single-core mm x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) flex. w/ wire end ferrule mm x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) single-core or stranded AWG x (0 - ) x (0 - ) x (0 - ) x (0 - ) x (0 - ). ABB Control Inc. 8//00 Proof AC 0 9/00
3 Selection guide C C C6.0 C6.0 C7 C9 C C C6.0 C6.0 C7 C9 Phase monitoring Level monitor Voltage monitor Voltage monitor Phase monitoring Power factor monitor Single phase Three phase Three phase Three phase 00V 00V 00V 00V 60V 0/60Hz 0/60Hz 0/60Hz 0/60Hz 0VAC 00VAC 0/60Hz x 00V 60V 0.8. Us Max. VA Max. 6 Max. - to +0/-0 to to +0/-0 to to +0/-0 to to +0/-0 to to +8/-0 to to +8/-0 to to +8/-0 to to +8/-0 to +70 IP IP IP IP IP IP IP 0 IP 0 IP 0 IP 0 IP 0 IP 0./0.89./0.89 /.78 /.78 /.78 /.78 N.O. SPDT SPDT SPDT SPDT SPDT AaCdO AaCdO AaCdO AaCdO AaCdO AaCdO 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w 000 VA or 90 w 8A VAC/ 0A VDC 8A VAC/ 0A VDC 8A VAC/VDC 8A VAC/VDC 8A VAC/ 0A VDC 8A VAC/ 0A VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 00mA VAC/VDC 80VAC 80VAC 80VAC/VDC 80VAC/VDC 80VAC 80VAC at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic at 000 VA ohmic 00,000 00,000 00,000 00,000 00,000 00, KV kv kv kv kv kv x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0. -.) x (0 - ) x (0 - ) x (0 - ) x (0 - ) x (0 - ) x (0 - ) ABB Control Inc.. 8//00 Proof AC 0 9/00
4 C0 Current monitor Measuring Rated control Weight Pieces/ Type range I s supply voltage Contact /piece unit VAC 0/60Hz VAC VDC (oz) pack C0 0 /0 0 N.O..8 SAR000R0007 $ 8 As soon as the value of the alternating current to be monitored reaches the threshold value set on the front panel, the output relay picks up after expiration of the permanently set delay time (00 ms). If the current drops below the set threshold value minus a fixed hysteresis of percent, the relay returns to its release condition after expiration of the permanently set delay T (0ms). Current monitoring, single phase AC for overcurrents Design with straight-through transformer Relay output, N.O. Overall width 7mm A/A A/A (+) A U C0 Threshold value I s Hysteresis Monitored measuring current Output relay T Rated control supply voltage U s V V U c, 00 0VAC Voltage tolerance Maximum power consumption VA 0 Frequency of the measured signal Hz 0 00Hz Threshold value Hysteresis Setting accuracy Repeat accuracy in the case of constant parameters ±0.% Deviations in the case of voltage fluctuations ±0.0%/V in the case of temperature fluctuations ±0.08%/ C Delay times on transgression of the threshold value ms 00 T on undershoot of the hysteresis of the hysteresis ms 0 ON delay ms maximum 0 ± % with VAC/VDC resp VAC Absolute value of measuring range -% fixed, of set threshold value ±0% referred to full scale value Load rating of the output relay A maximum Ambient operation C/ F -0 to +60/- to +0 temperature storage C/ F -0 to +70/- to +8 Conductor single core mm x (0. to.) connection flexible with wire and ferrule mm x (0. to.) Enclosure IP0 terminals, IP0 housing AWG x (0-7) I I R (-) A A. ABB Control Inc. 6/6/00 Proof AC 0 7/00 In the case of sinusoidal currents. Measuring principle: Arithmetic averaging.
5 C Current monitor Type Measuring Rated control Weight Pieces/ range I s supply voltage Contacts /piece unit VAC 0/60Hz VAC VDC (oz) pack SAR00R000 SAR00R000 C SPDT.9 SAR00R000 $ 7 ( ranges) 0 SAR00R000 0 SAR00R000 SAR00R000 SAR00R000 C SPDT.9 SAR00R000 7 ( ranges) 0 SAR00R000 0 SAR00R000 C A/A A/A T T T T T T Without latching 6 T T 6 With latching Threshold value Hysteresis Monitored measuring current Output relay, function OVER Output relay, function UNDER 6 Latching Current monitoring without latching: As soon as the value of the alternating current or direct current to be monitored reaches the threshold value set on the front panel, the output relay drops out after expiration of the set time. The relay picks up immediately again when the current has reached the hysteresis value again. Current monitoring with latching: If the set limit value is reached, the output relay drops out after expiration of the set time and remains latched in this position even if the measuring current once again assumes a permitted value. Function overcurrent (OVER) and undercurrent (UNDER) Owing to the ON delay T, current peaks (function OVER) resp. current fades (function UNDER) which may occur on make do not lead to a change in the relay state. The delay time prevents a disturbing, constant switch-on and switchoff of the relay if the measured value is near to the set threshold value. Current monitoring, single phase AC and DC for overcurrent or undercurrent yellow LED for indication of the relay state green LED for indication of the supply voltage applied Relay output, changeover contact Type C.0 C.0 Rated control supply voltage U s V See selection data (electrical isolation by means of transformer does not apply in the case of DC) Voltage tolerance Maximum power consumption VA 0.8. x U s Frequency of the measured signal Hz 0 00 and DC Threshold value adjustable 0 00% of the measuring range Hysteresis adjustable 0% of the set threshold value Setting accuracy ±0% referred to full scale value Repeat accuracy in the case of constant parameters ±0.% Deviations in the case of voltage fluctuations ±0.%/V in the case of temperature fluctuations ±0.0%/ C Delay times T ON delay s 0 ±0% on reaching the threshold value s 0. ±0% Measuring ranges Inputs E-M E-M E-M E-M E-M E-M Sensitivity A Input resistance Ohm Overcurrent resistance, sustaineda s A Function setting With or without memory and undervoltage or overvoltage Slide switch Load rating of the output relay A maximum 8 Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 Conductor connection single-core mm x (0..) flexible with wire end ferrule mm x (0..) Enclosure IP0 terminals, IP0 housing In the case of sinusoidal currents. Measuring principle: Arithmetic averaging. ABB Control Inc.. 6/6/00 Proof AC 0 7/00
6 C Voltage monitor Type Measuring Rated control Weight Pieces/ range I s supply voltage Contacts /piece kg unit VAC 0/60Hz VAC VDC (oz) pack SAR00R000 C SAR00R000 $ 7 ( ranges) 0 SPDT. SAR00R000 0 SAR00R000 SAR00R000 C SAR00R000 7 ( ranges) 0 SPDT. SAR00R000 0 SAR00R000 C.0 A/A A/A Without latching 6 With latching Threshold value I s Hysteresis Monitored voltage Output relay, function OVER Output relay, function UNDER 6 Latching 6 Voltage monitoring without latching: As soon as the measuring-circuit voltage reaches the set threshold value, the output relay changes its circuit state after expiration of the set time. It returns immediately to the original state when the measuring-circuit voltage reaches the set hysteresis value. Voltage monitoring with latching: If the set threshold value is reached, the output relay changes its circuit state after expiration of the set time and remains latched in this position even if the measuring-circuit voltage once again assumes a permitted value. Voltage monitoring, single phase for overvoltage or undervoltage With or without latching yellow LED for indication of the relay state: blinks during the operating time green LED for indication of the control voltage applied Relay output, changeover contact Type C.0 C.0 Rated control supply voltage U s V See selection data (electrical isolation by means of transformer does not apply in the case of VDC) Voltage tolerance Maximum power consumption VA 0.8. x U s Frequency of the measured signal Hz 0 00 and DC Threshold value Hysteresis Setting accuracy Delay times on reaching the threshold value Adjustable from 0 00% of the measuring range Adjustable from 0% of the set threshold value ±0% referred to full scale value s adjustable 0. Measuring ranges Inputs E-M E-M E-M E-M E-M E-M Sensitivity V Input resistance kohm Overvoltage resistance V Function setting With or without memory Undervoltage or overvoltage Slide switch Load rating of Rated operating current the output relay //AC-, 0V A maximum 8 Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 Conductor connection single-core mm x (0..) flexible with wire end ferrule mm x (0..) Enclosure IP0 terminals, IP0 housing.6 ABB Control Inc. 6/6/00 Proof AC 0 7/00
7 C Voltage monitor with two limit values (+) A U C Hysteresis Monitored voltage 7 Upper threshold value 8 Lower threshold value 9 Output relay Type Measuring range Weight Pieces/ = rated control supply voltage U s Contacts /piece kg unit VAC (oz) pack C 0 80VAC/VDC SAR00R0008 SPDT. 6 60VAC/VDC SAR00R0009 Relay C monitors a voltage corresponding to its own control supply voltage. As soon as the monitored voltage value leaves the set range, the output relay drops out after the set time has elapsed. Voltage monitoring, single phase for overvoltage or undervoltage yellow LED for indication of the relay state green LED for indication of the control voltage applied Relay output, changeover contact Rated control supply voltage U s V See evaluation data (with reverse voltage protection) Voltage tolerance Maximum power consumption VA. See evaluation data Frequency of the measured signal/power system Hz 0/60 and DC Threshold value Hysteresis Setting accuracy Delay times on reaching the threshold value Absolute scale within the measuring range Fixed % of the set threshold value ±0% referred to full scale value s 0. - $ 0 Measuring ranges Inputs A A Sensitivity V See selection data, measuring range of version Input resistance kohm Overvoltage strength V See selection data, upper value of the rated control supply voltage Load rating of rated operating current the output relay AC-, 0V A maximum 8 Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 Conductor connection single-core mm x (0..) flexible with wire end ferrule AWG x (0-7) mm x (0..) Enclosure IP0 terminals, IP0 housing U R (-) A ABB Control Inc..7 6/6/00 Proof AC 0 7/00
8 C Phase monitor U L L L C T Output relay Delay on pickkup, 00ms T Delay on dropout, maximum 00ms T L L Measuring Rated control Weight Pieces/ Type range Is supply voltage Contacts /piece unit VAC 0/60Hz VAC (oz) pack C x x SPDT. SAR000R000 $ 7 Relays for phase monitoring monitor the phase sequence and failure of one of the three phases. No settings are required during operation. If the phase sequence is correct and none of the three phases has failed, the output relay picks up after the delay time and the LED lights. In the event of a phase failure or fault, the output relay drops out after the delay time T has elapsed and the LED goes out. If a phase sequence error occurs on switch-on of the voltage, the relay does not pick up. Note: Relay C is not protected against reverse voltage. If there is a risk of energy recovery from a motor in the event of phase failure, relay C7 with monitoring of phase asymmetry can be used. Phase monitoring, three phase phase failures and phase sequence yellow LED for indication of the relay state (OK state) Relay output, changeover contacts Rated control supply voltage U s V x 0 00, the monitored power system simultaneously serves to power the relay Voltage tolerance x Power consumption at 00V VA at 00V VA 0 at 60V VA Frequency of the measured power system Hz 0/60 Delay time with correct phase sequence ms maximum 00 T in the case of phase failure ms approximately 00 Load rating of the output relay Making/breaking capacity AC VA maximum 000 DC W maximum 80 Switched current AC/DC A maximum 8 Switched voltage AC/DC V maximum 0 Disruptive strength in accordance with IEC -.kv/ min. Electrical service life operations 0 at maximum making/breaking capacity Mechanical service life operations x 0 Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 Conductor connection single-core mm x (0..) flexible with wire end ferrule mm x (0..) Enclosure IP0 terminals, IP0 housing.8 ABB Control Inc. 6/6/00 Proof AC 0 7/00
9 C Level monitor for conductive fluids Measuring range Weight Pieces/ Type = rated control supply voltage U s Contacts /piece unit VAC (oz) pack VAC C 8VAC 0VAC SPDT.9 0VAC SAR000R000 SAR000R000 SAR000R000 SAR000R000 $ 9 A/A C T Maximum level Minimum level Monitored level Output relay, function down Output relay, function up T The supply voltage must be interrupted for at least 0.s in order to reset the device The basic mode of operation is based on measurement of the impedance of the fluid between two submersible probes. If the measured value is less than the threshold value set on the front panel, the actual relay changes its circuit state. In order to preclude the effects of electrolysis phenomena, the probes operate with AC. Regulating two levels: The output relay changes its circuit state as soon as the fluid level reaches the maximum probe whilst the minimum probe is immersed. It returns to the original circuit state as soon as the minimum probe is no longer in contact with the fluid. Level monitoring of conductive fluids Selectable supply or discharge monitoring yellow LED for indication of the relay state green LED for indication of the control supply voltage applied Relay output, changeover contact Rated control supply voltage U s V See evaluation data Voltage tolerance Emergency failure stored energy time ms 00 Maximum power consumption VA 0.8. X U s Function setting supply or discharge monitoring Slide switch OVER/UNDER Sensitivity adjustable kh 00 Measuring accuracy at maximum sensitivity 0 to +0% Electrode voltage max (0/60 Hz) V Electrode current max. (0/60 Hz) ma Cable capacitance with special cable nf 0 Delay times upper level, terminal Max-M ms 00 lower level, therminal Min-M ms 00 Electrical isolation by means of transformer (kv, 8mm creepage distance) Class II in accordance with DIN VDE 0 Insulation voltage of the contacts and the electrodes with respect to the power supply V 00 Load rating of the output relay A maximum 8 Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 Conductor connection single-core mm x (0..) AWG x (0-7) flexible with wire end ferrule mm x (0..) Enclosure IP0 terminals, IP0 housing Filling level monitoring Up Pump-off monitoring down The special cable (maximum 00m) does not need to be shielded but we do not advise laying this cable in parallel with power supply cables. A shielded line may also be used, whereby the shield must be connected to terminal M. ABB Control Inc..9 6/6/00 Proof AC 0 7/00
10 C6.0 Voltage monitor between phases and neutral conductor in three phase power systems C6.0 U Threshold value Umax Hysteresis Threshold value Umin Output relay Umin Output relay Umax L L L T L/L L/L L/L Measuring range Weight Pieces/ Type = rated control supply voltage U s Contacts /piece unit VAC (oz) pack C6.0 00VAC SPDT SAR000R0006 $ 6 The output relay picks up as soon as the values of the three star voltages of the phases with respect to the neutral conductor lie between the lower and upper threshold value. The threshold values are set separately via two potentiometers on the device front panel. If the value of one voltage is outside of this range, the corresponding output relay drops out after a delay time or T (which can be set on the front panel) has elapsed. A fixed hysteresis of % prevents continuous switch-on and switch-off of the output relay if the measuring circuit voltage is near to a set threshold value. The phase sequence and phase asymmetry are not monitored. Device C6.0 also responds to failure of the neutral conductor. Voltage monitoring in three phase power systems with neutral conductor Measures its own supply voltage Relay for monitoring overvoltages and undervoltages Lower and upper threshold value separately settable Detection of phase failures Does not respond to incorrect phase sequence Indication of overvoltage, undervoltage and relay status via three LEDs Delay if the threshold value is overshot or undershot can be set on the front panel between 0. and 0s Two output relays: changeover contact 8A: Overvoltage changeover contact 8A: Undervoltage Overall width: mm /.78 in. Lower threshold value 80 98%U n Upper threshold value Electrical isolation Power system monitoring Frequency of the monitored power system Hysteresis Indicating accuracy 0 0% U n by means of transformer x 00VAC 0/60 Hz Repeat accuracy in the case of constant parameters ± 0.% fixed, % of the set threshold value ±0% of the scale value Delay on transgression of the threshold values 0.s 0s, 0 + 0% Output relay (in accordance with AC-, resistive load) AgCdO changeover contacts, 8A AC The special cable (maximum 00m) does not need to be shielded but we do not advise laying this cable in parallel with power supply cables. A shielded line may also be used, whereby the shield must be connected to terminal M..0 ABB Control Inc. 6/6/00 Proof AC 0 7/00
11 C6.0 Voltage monitor for three phase power systems Measuring range Weight Pieces/ Type = rated control supply voltage U c Contacts /piece unit VAC (oz) pack C6.0 00VAC SPDT 0.6 SAR00R0006 $ 6 C6.0 U Threshold value Umax Hysteresis Threshold value Umin Output relay Umin Output relay Umax T L/L L/L L/L The output relay picks up as soon as the values of the three phase-to-phase voltages lie between the lower and upper threshold value. The threshold values are set separately via two potentiometers on the device front panel. If the value of one voltage is outside of this range, the corresponding output relay drops out after a delay time or T (which can be set on the front panel) has elapsed. A fixed hysteresis of % prevents continuous switch-on and switch-off of the output relay if the measuring circuit voltage is near to a set threshold value. The phase sequence and phase asymmetry are not monitored. in three phase power systems with neutral conductor Measures its own supply voltage Relay for monitoring overvoltages and undervoltages Lower and upper threshold value separately settable Detection of phase failures Does not respond to incorrect phase sequence Indication of overvoltage, undervoltage and status via three LEDs Delay if the threshold value is overshot or undershot can be set on the front panel between 0. and 0s Two output relays: changeover contact 8 A: Overvoltage changeover contact 8 A: Undervoltage Overall width: mm /.78 in. Lower threshold value 80 98%U n Upper threshold value Electrical isolation 0 0%U n by means of transformer Power system monitoring x 00VAC +N Frequency of the monitored power system Hysteresis Indicating accuracy 0/60 Hz Repeat accuracy in the case of constant parameters ± 0.% fixed, % of the set threshold value ±0% of the scale value Delay on transgression of the threshold values 0.s 0s, 0 + 0% Output relay (in accordance with AC-, resistive load) AgCdO changeover contacts, 8A AC The special cable (maximum 00m) does not need to be shielded but we do not advise laying this cable in parallel with power supply cables. A shielded line may also be used, whereby the shield must be connected to terminal M. ABB Control Inc.. 6/6/00 Proof AC 0 7/00
12 C7 Phase monitor relay Measuring range Weight Pieces/ Type = rated control supply voltage U s Contacts /piece unit VAC (oz) pack C7 0VAC 00VAC SPDT. SAR00R000 SAR00R0006 $ 7 C7 L L L T T T L L In a three-phase power system, the phase monitor relay simultaneously monitors the phase sequence, phase loss with a maximum phase energy recovery of 70% of the voltage set on the front panel via a potentiometer and a symmetrical drop of the voltage of the three phases below % of the preset value. If the phase sequency of the three phases is correct, the output relay operates, indicated by a green LED. The output relay drops out after a delay time T which can be set on the front panel between 0. and 0s (and the LED goes out) if one of the following faults occurs: Reversal of the direction of rotation Failure of one or more phases Voltage drop. Note: Delay T does not occur in the event of failure of L and L but only in the event of failure of L, phase reversal or voltage drop. It is used to prevent the output relays from chattering in the case of transitional situations occuring particularly, when starting motors. phase sequence, phase failure and asymmetry of: phase failure, failure of at least one phase, undervoltage Monitors its own supply voltage Asymmetry adjustable via potentiometer Delay in the event of fault can be set between 0. and 0s Relay output, two changeover contacts One green LED for indication of the supply voltage applied One yellow LED for indication of the relay state Supply voltage Own power supply terminals L + L Operating range 0.7 to. x Un Frequency 0/60Hz Power consumption maximum 6VA Insensitivity to brief power failures 0ms Response time 00ms Insulation voltage Overvoltage category III, pollution serverity in accordance with IEC 66-, VDE00: kv/ Input circuit Resistance of the measurement input kh x UN Phase energy recovery maximum 70% of the set threshold value Undervoltage detection (symmetrical drop out) -% of the threshold value Indicating accuracy of the threshold value ±0% Output relay changeover contacts AgCdO Making/breaking capacity 000VA AC 80 W Maximum switched current 8 A AC Minimum switched current 00 ma AC Maximum switched voltage 0VAC Time delay if fault occurs 0. 0s (0 to +0%) Ambient Operation C/ F -0 to +60/- to +0 temperature Storage C/ F -0 to +70/- to +8 The special cable (maximum 00m) does not need to be shielded but we do not advise laying this cable in parallel with power supply cables. A shielded line may also be used, whereby the shield must be connected to terminal M.. ABB Control Inc. 6/6/00 Proof AC 0 7/00
13 C9 cos ϕ monitor Measuring range Weight Pieces/ Type = rated control supply voltage U s Contacts /piece unit VAC (oz) pack C9 0VAC 00VAC SPDT 0.60 SAR6000R000 SAR6000R0006 $ 68 C9 the power factor (cosine ϕ) motor overload and underload Measurement of the phase shift between current and voltage (cos ϕ) Independent setting of the minimum and maximum threshold value between 0 and 0.99 ON delay can be set on the front panel between 0. and 0s Delay in the event of a fault between 0. and s Two changeover contact outputs 8 A Overall width: mm /.78 in. Hysteresis Indicating accuracy Output relay (in accordance with AC-, resistive load) % at start of scale % at end of scale ±% of the scale value AgCdO changeover contacts, maximum 8A AC The special cable (maximum 00m) does not need to be shielded but we do not advise laying this cable in parallel with power supply cables. A shielded line may also be used, whereby the shield must be connected to terminal M. ABB Control Inc.. 6/6/00 Proof AC 0 7/00
14 Conformity with the following standards: VDE 0 General Guidelines for Electrical Relays VDE 0609 Connection by Means of Screw-Type Terminals VDE 00 Creepage Distances VDG Shock-Hazard protection IEC 8- Guidelines for Low-Voltage Switchgear IEC (relevant parts) General Guidelines for Measuring and Protective Relays IEC 80- Interference Immunity DIN 677 Mounting on DIN Rails IEC 9 Enclosure General technical data C0 Housing material Self-extinguishing Relative humidity 9% Operating temperature -0 to +60 C Storage temperature -0 to +70 C Enclosure Housing IP 0, terminals IP 0 Output: C- C9 Relay contact NO or changeover contacts Contact material AgCdO Max. permissible making/breaking capacity 0 VA 000 VA, oder 90W Max. switched current A AC/DC 8A AC / 0A DC Min. switched current 0mA AC/DC 00mA AC/DC Max. switched voltage 0V AC/DC 80V AC Electrical service life 0 operations at 0 operations at 0 VA ohmic 000 VA ohmic Mechanical service life 0 x 0 6 operations x 0 6 operations Insulation contact/coil kv Connection cross-sections x. mm flexible with wire end ferrules x. mm single-core. ABB Control Inc. 6/6/00 Proof AC 0 7/00
15 Approximate dimensions C, C, C, C, C C Ø C6.0, C6.0, C7, C ABB Control Inc.. 8//00 Proof AC 0 9/00
Current monitor Type C 551
Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationEMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description
3-Phase Voltage Monitoring Relay INTERFACE Data Sheet PHOENIX CONTACT - 03/2006 Description Voltage monitoring in 3-phase networks with settable threshold values, settable response delay, monitoring of
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationThree-phase monitoring relay
1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationMoeller Electric Corporation
EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationProtection and safety SQZ3 phase and sequence relay
SQZ3 phase and sequence relay Supply voltage [Vn] 400 V a.c. Frequency [Hz] 0/60 SQZ3 2CSC4001F0201 Contact type [A] 1 CO, 20 V, 10 A (cos =1) safety switching Minimum voltage adjustment trimmer [%] 100
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationElectronic measuring and monitoring relays CM-range
Electronic measuring and CM-range Content Benefits and advantages CM range, function overview... 30 Selection and ordering details Current and voltage monitors, single phase... 33 Three phase monitors...
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content
ABB Measuring and monitoring relays CM and C5xx range Content Benefits and advantages, overview of features... 60 Approvals and marks... 64 Current and voltage monitors, single-phase... 65 Ordering details...
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationAdvantages. Applications
3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationXUA1 - AC Voltage and phase balance relay
XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 DPC01 PPC01 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect
More informationThree-phase monitoring relay
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More information650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN
650 PHOENIX CONTACT Monitoring relays, timer relays, function blocks The requirements pertaining to safety and system availability are constantly increasing regardless of the industry. Processes are becoming
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 DPC71 PPC71 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationThree-phase monitoring relays Product group picture
Product group picture /7 ABB Catalog Electronic Products and Relays 013/014 CDC 110 004 C009 Table of contents Three-phase monitoring relays Product group picture 7 Table of contents 8 Benefits and advantages,
More informationThree-phase monitoring relays Product group picture
Product group picture /7 ABB Catalog Electronic Products and Relays 015 CDC 110 004 C010 Table of contents Three-phase monitoring relays Benefits and advantages, Applications /9 Operating controls /30
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationThree-phase monitoring relays Table of contents
Table of contents Three-phase monitoring relays Three-phase monitoring relays 78 Benefits and advantages, Applications 79 Operating controls 80 Selection table - Singlefunctional 81 Ordering details -
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationElectronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationThree-phase monitoring relay CM-PBE
Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPhase sequence and phase failure monitor
Measuring and monitoring relay Measuring and monitoring relay Current and voltage monitor Detection of falling below and exceeding a set threshold value of voltages and currents Phase sequence and phase
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01
Monitoring Relays True RMS 3-Phase, 3-Phase+, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationXP2-R Power and Reverse Power Relay
XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC
Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel
More informationXP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)
XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationMultifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72
Data sheet Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 The three-phase monitoring relays CM-MPN.x2 monitor the phase parameters phase sequence, phase failure,
More informationInsulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.x serves to monitor insulation resistance in accordance with IEC
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationEasy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays
EMR6 EMT6 ETR4 www.eaton.eu Easy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays The measuring and monitoring of industrial applications made simple - with the EMR6 With
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More information