Ratings for Switching AC Motors AC-2, AC-3, AC / /
|
|
- Gloria Walton
- 5 years ago
- Views:
Transcription
1 Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor sizes Front and side mounting of auxiliary contacts Electronic and pneumatic timing modules Space-saving coil-mounted control modules Reversible coil terminations (line or load side) All devices can be attached to mm DIN mounting Rail Environmentally friendly materials The Bulletin -C/-C IEC contactor family, along with a wide range of common accessories and Bulletin solid-state overload relays, provides the most compact and flexible starter component system available. Your order must include: cat. no. of the contactor specified with coil voltage code and, if required, cat. no. of any accessories and/or replacement coils. Ratings for Switching AC Motors AC-, AC-, AC- -Phase kw ( Hz) Hp ( Hz) Table of Contents Product Selection... this page Accessories... - Approximate Dimensions... - Standards Compliance EN/IEC --, -- IEC Type Coordination CSA C. No. UL Meets the material restrictions for European Directive //IEC-EU-RoHS Certifications CE Marked culus Listed (File No. E; Guide NLDX, NLDX) CCC Aux. Contacts V/ -Phase -Phase AC- AC- V V V V V V V V V V N.O. N.C. Cat. No. / -/ -/ -C -C... / -/ -C -C.... -C -C. -/ -C -C -C -/ -C -C -C./. -C -C -C -/ -C -C -C. -C -C -C -C -C -C -/ -C -C -C -C -C For screwless terminals, add an "R" after the letter "C" in the catalog number. Example: Cat. No. -C becomes Cat. No. -CR. Coil voltage code and terminal position see page - Publication A-CAA-EN-P -
2 Bulletin -C/-C Product Selection Reversing AC- and DC-Operated Contactors Cat. No. -CD Cat. No. -CZJ Cat. No. -CD I e [A] -Phase kw ( Hz) AC- AC- V V/V V V Ratings for Switching AC Motors AC-, AC-, AC- -Phase Hp ( Hz) -Phase Auxiliary Contacts Installed per Contactor V V V V V V N.O. N.C. Cat. No. / -/ -/ -C... / -/ -C.... -C. -/ -C -/./... -/ -C -C -C -C -C -C -C -C -C -C -C -C -C -C The N.C. auxiliary contact is supplied as part of the mechanical/electrical interlock. Coil Voltage Code and Terminal Position The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: V, Hz: Cat. No. -C becomes Cat. No.-CD. [V] Hz Hz R K V W X Y KP D P S KG L F VA T N G B M C Hz Q J V X KP D KG H L A T I E N B C / Hz KJ KY KP KD KG KL KL KF KA KN KB Not available on /-C or -C contactors. DC Voltages [V] Standard ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE ZD ZP ZS ZA ZF ZT -C C with Integrated Diode DJ Electronic with Integrated Diode EQ EJ EY ED EA -C C with Integrated Diode DR DQ DJ DW DY DZ DB DG DE DD DP DS DA DF DT Coil Terminal Position All contactors are delivered with the coil terminals located on the line side. For load side coil terminations, insert a U prior to the coil voltage code. Ordering example: Cat. No. -CUD. Publication A-CAA-EN-P Cat. No. -C Line Side Cat. No. -CU Load Side -
3 Bulletin Line Assignment of Contacts Assignment of Contacts Auxiliary Contact Blocks Circuit Diagram Side Mounting -SB -SB -SB -SB -SB -SBL Control K -C_ -C_ -C_ -C_ A A K -C_ -C_ -C_ -C_ A A Contactors -C (AC and DC Control) -C_ -C_ -C_ -C_ -C_ -C_ -C_ K A A -C_ -C_ -C_ -C_ -C_ -C_ K A A -C_ -C_ -C_ -C_ K A A R R -C_ -C_ -C_ -C_ -C_ -C_ K A A R R R R AC/DC + = + = + = + = + = + = AC/DC + = + = + = + = + = + = AC/DC + = + = + = + = + = AC/DC + = + = + = + = + = + = AC/DC + = + = + = + = + = + = AC/DC + L = L + L = L + L = L + L = L + L = L + L = L Up to auxiliary contacts possible: contactor + front mounted (AC max. N.C. / DC max. N.C.), side mounted (AC max. N.O. / DC max. N.O. and max. N.C.). Early make and/or late break. Double numbering: because of double numbering only left-side mounting is recommended. - Publication A-CAA-EN-P
4 Bulletin -C/-C Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Bulletin -C Contactors and Accessories c Mounting Position c c AC contactors and DC contactors with electronic coils DC contactors AC Contactors and DC Contactors with V or V Electronic Coils Cat. No. a b c c c Ød d d -C -C (-/) (-/). (-/). (-/) (/) -. ( -/) (-/) (-/) -C, -C (-/) (-/). (). (-/). (/) -. ( -/) (-/) (-/) -C (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -C (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -C -C (-/) (-/) (-/). (-/). (/) -. ( - /) (-/) (-/) -C (-/) (-/) (-/). (-/). (/) -. ( - /) (-/) (-/) DC Contactors with Conventional Coils Cat. No. a b c c c Ød d d -CZ -CZ (-/) (-/). (-/). () (/) -. ( -/) (-/) (-/) -CZ (-/) (-/). (-/) (-/) (/) -. ( -/) (-/) (-/) -CZ -CZ (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -CZ (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -CZ (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -CD -CD (-/) (-/) (-/). (-/). (/) -. ( -/) (-/) (-/) -CD (-/) (-/) (-/). (-/). (/) -. ( - /) (-/) (-/) DC Contactors with V or V DC Electronic Coils Cat. No. a b c c c Ød d d -CE -CE (-/) (-/). (-/). (-/) (/) -. ( -/) (-/) (-/) -CE -CE (-/) (-/). (). (-/). (/) -. ( -/) (-/) (-/) -CEA -CED (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) -CEA -CED (-/) (-/). (-/). (-/). (/) -. ( -/) (-/) (-/) Accessories Contactors with mm (inches) Auxiliary contact block for front mounting - or -pole c/c + (c/c + -/) Auxiliary contact block for side mounting - or -pole a + (a + /) Pneumatic Timing Module c/c + (c/c + -/) Electronic Timing Module on coil terminal side b + (b + /) Mechanical Interlock on side of contactor a + (a + /) Mechanical Latch c/c + (c/c + -/) Interface Module on coil terminal side b + (b + /) Surge Suppressor on coil terminal side b + (b + /) Labeling with Terminal Lug Kit Paralleling Links - label sheet + (+ ) marking tag sheet with clear cover + (+ ) marking tag adapter for System V / V +. (+ /) marking tag adapter for System Bul. W +. (+ /) -C C b + (b + -/) -C b + (b + -/) -C b + (b+ -/) -C C b + (b + -/) -C C b + (b + -/) c + / (c + /) -C C b + (b + -/) Publication A-CAA-EN-P
5 Bulletin /-K, /-C, /-D, S/S-C, S-D -KR /-K /-C, S/S-C * * Coil Type : Conventional X X X X X X X X X X X X X X X Electronic EI AC- Active Power Load ( Hz); Ambient temperature C V [A] () V [A] () V [A] V [kw] I e V [kw]... V [kw].. V [kw] V [kw].. V [kw] V [kw] Ambient temperature C V [A] V [A] V [A] V [kw]... I e V [kw]... V [kw].. V [kw] V [kw].. V [kw] V [kw] Switching of -phase Motors; ( Hz) Ambient temperature C, AC-, AC- V [A] V [A] V [A]..... V [A]..... V [A]..... V [A]..... V [A] V [kw] V [kw] V [kw] V [kw]..... V [kw] V [kw] V [kw] Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) [A] Rated power (enclosed) V [A] phase V [A]. V [Hp] / /..... V [Hp] /... V [A] V [A] V [A] phase V [A].... V [Hp]... V [Hp]... V [Hp].. V [Hp].. - Publication A-CAA-EN-P
6 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X AC- Active Power Load ( Hz); Ambient temperature C Ambient temperature C Switching of -phase Motors; ( Hz) Ambient temperature C, AC-, AC- () () () () () () () () () () () () () () () (). Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) Rated power (enclosed) V: values in ( ) AC- and AC- lifespan - % Publication A-CAA-EN-P -
7 Bulletin /-K, /-C, /-D, S/S-C, S-D /-K /-C, S/S-C Conventional X X X X X X X X X X X Coil Type : Electronic EI Switching of -phase Motors, (Hz); Ambient temperature C, AC- V [A].... V [A].... V [A]... V [A]... V [A]... V [A]... V [A] V [kw].... V [kw].... V [kw]..... V [kw].... V [kw].... V [kw]..... V [kw] AC- at approximately, operations V [A] V [A] /V [A] V [A] V [A].... V [A] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw]... V [kw] Max. switching frequency Ops/h Wye-Delta ( Hz) V [Hp]. ½ ½ V [Hp]. ½ V [Hp]. V [Hp]. UL/CSA Elevator Duty V [A] V [A] V [A] V [A] V [Hp] ½ ½ V [Hp] ½ V [Hp] ½ V [Hp] ½ Star-Delta Starting ( Hz) V [A]. V [A]. V [A]... V [A]... V [A]... V [A].... V [A] V [kw].... V [kw]..... V [kw].. V [kw].. V [kw]... V [kw].... V [kw] Power ratings at Hz: Preferred values according to IEC - Approval pending on Cat. No. -D D. - Publication A-CAA-EN-P
8 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D X X X X X X X X X X X X X X X Switching of -phase Motors, ( Hz); Ambient temperature C, AC- () () () () () () () () () () () () () () () () AC- at approximately, operations.... Wye-Delta ( Hz) UL/CSA Elevator Duty.. TBD.. TBD.. TBD.. TBD TBD TBD TBD TBD Star-Delta Starting ( Hz) () () () () () () () () () () () () V: Values in ( ) AC- and AC- lifespan -% Approval pending on Cat. No. -D D. Publication A-CAA-EN-P -
9 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type : /-K /-C, S/S-C Conventional X X X X X X X X X X X Electronic EI Switching of Power Transformers, AC-a ( Hz) Inrush Current Rated transformer current = n V [A] V [A] V [A] V [A] V [A] V [A]..... n = V [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] n = V [A] n = V [A] Hz Peak Inrush/peak rated transformer current n = [A]..... V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Hz Peak Inrush/peak rated transformer current n = [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Hz Peak Inrush/peak rated transformer current n= [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Publication A-CAA-EN-P
10 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D X X X X X X X X X X X X X X X Switching of Power Transformers, AC-a ( Hz) Hz Peak Inrush/peak rated transformer current Hz Peak Inrush/peak rated transformer current Hz Peak Inrush/peak rated transformer current Publication A-CAA-EN-P -
11 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type : Switching of -phase Capacitors, AC-b ( Hz) /-K /-C, S/S-C * * Conventional X X X X X X X X X X X X X Electronic EI V [kvar]. V [kvar]. V [kvar]. Single capacitor C V [kvar]. V [kvar]. V [kvar]. V [kvar] V [kvar]... V [kvar]... V [kvar].. C V [kvar]. V [kvar]. V [kvar]. V [kvar] V [kvar]. V [kvar]. V [kvar] Group capacitors C V [kvar] V [kvar] V [kvar] V [kvar] V [kvar].. V [kvar].. V [kvar] C V [kvar] V [kvar] V [kvar] V [kvar] Hz Single Capacitor C V [kvar]. V [kvar]. V [kvar] V [kvar] Hz Group Capacitors C V [kvar].. V [kvar].. V [kvar] V [kvar] Switching of Lamps Gas discharge lamps AC-a, C open [A].. enclosed [A].... Individually compensated: Max. capacitance at expected Short-circuit current of ka [μf] ka [μf] ka [μf] Filament AC-b /V [A] Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC ( Hz) V [A] AC-a V [A] V [A] Switching of Motor Load for Home Appliances ( Hz) AC-b V [A]. V [A] V [A].. Inductance of leads between capacitors in parallel: min. μh (-C C contactors: min μh) - Publication A-CAA-EN-P
12 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X Switching of -phase Capacitors, AC-b ( Hz) Hz Single Capacitor C Hz Group Capacitor C Switching of Lamps Individually compensated: Max. capacitance at expected Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC ( Hz) Switching of Motor Load for Home Appliances ( Hz) Publication A-CAA-EN-P -
13 Bulletin /-K, /-C, /-D, S/S-C, S-D /-K /-C, S/S-C * * Conventional X X X X X X X X X X X X X Coil Type : Electronic EI Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release ( Hz) V [A] AC-a V [A] V [A] - automatic reset of overload release V [A].. AC-b V [A].. V [A].. Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-, C V [A] /V [A] / /. /. pole V [A]. V [A] V [A] V [A] /V [A] poles in series V [A] V [A]... V [A].... V [A] /V [A] poles in series V [A] V [A] V [A] Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-, C V [A] /V [A] poles in series V [A] V [A]... V [A] Series-wound Motors Starting, reverse current braking, reversing, stepping DC-, C V [A] /V [A] poles in series V [A]. V [A]... V [A] Short Time Withstand I CW, C s [A] Resistance and Power Dissipation Main current circuit resistance [mω] Power dissipation by all circuits at I e AC-/V [W] Total power dissipation At I e AC-/V AC [W] DC [W] Lifespan Mechanical AC control [Mil. operations] Mechanical DC control [Mil. operations] Electrical AC- ( V) [Mil. operations] Weight AC DC Non- Rev. Rev. Non- Rev. Rev. kg (lbs.) kg (lbs.) kg (lbs.) kg (lbs.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) - Publication A-CAA-EN-P
14 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release ( Hz) - automatic reset of overload release Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-, C Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-, C Series-wound Motors Starting, reverse current braking, reversing, stepping DC-, C Short Time Withstand I CW, C Resistance and Power Dissipation Total power dissipation.... (.) (.) Lifespan Weight. (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) Values in brackets refer to electronic coil (EI) version.. (.) [. (.)]. (.). (.). (.). (.). (.). (.). (.). (.). (). (). (.) [. (.)]. (.). (.). (.). (.). (.). (.). (.). (.). (). () Publication A-CAA-EN-P -
15 Bulletin /-K, /-C, /-D, S/S-C, S-D -KR /-K /-C, S/S-C Coil Type : Conventional X X X X X X X X X X X X X X X X X Conductor Cross Sections - Main Contacts Terminal type Electr. EI () conductor [mm] () conductors [mm] () conductor [mm] () conductors [mm] b max. [mm] c max. [mm] s max. [mm] Ø min. [mm] Recommended torque [N m] Cross section per UL/CSA [AWG] Recommended torque [lb-in]... With terminal lug kit Cross section per UL/CSA [AWG] Recommended torque [lb-in] With Frame Terminal Block top opening [mm] bottom opening [mm] top opening [mm] bott. opening [mm] b max. s top s bottom [mm] Recommended torque [N m] Cross section per UL/CSA top [AWG] bottom [AWG] Recommended torque [lb-in] Pozidriv No. / Blade No. screw Pozidriv No. / Blade No. screw Hexagonal socket screw Fine- or coarse-stranded only - Publication A-CAA-EN-P
16 Bulletin /-K, /-C, /-D, S/S-C, S-D /-D, S-D X X X X X X X X X X X X. x x.. -DL -DL -DL -DL MCM (x) MCM (X) / MCM (X) / MCM -DTB -DTB / AWG AWG MCM AWG MCM AWG MCM Pozidriv No. / Blade No. screw Pozidriv No. / Blade No. screw Hexagonal socket screw Hexagonal screw Publication A-CAA-EN-P -
17 Bulletin /-K, /-C, /-D, S/S-C, S-D Short-Circuit Coordination Data Coil Type : /-K /-C, S/S-C * * * * Conventional X X X X X X X X X X X X X X X X X X Electronic El Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC -- (contactor and fuses only) DIN Fuses - gg, gl ka Available Fault Current Type "" (V) [A] Type "" (V) [A] Type "" (V) [A] BS Fuses ka Available Fault Current Type "" (V) [A] TBD Type "" (V) [A] TBD Per UL and CSA. No. (contactor and fuses or circuit breaker only) UL Class K and RK Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class K and RK Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class CC and CSA HRCI-MISC Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class J and CSA HRCI-J Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class CC and CSA HRCI-MISC Fuses ka Available Fault Current UL verified combination to IEC -- "Type " [A] UL Class J and CSA HRCI-J Fuses ka Available Fault Current UL verified combination to IEC -- "Type " [A] TBD UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] TBD UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] TBD A max. fuse for Type coordination. See for complete short-circuit current ratings. - Publication A-CAA-EN-P
18 Bulletin /-K, /-C, /-D, S/S-C, S-D /-D, S-D / X X X X X X X X X X X ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current To be determined. Publication A-CAA-EN-P -
19 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type - /-K Publication A-CAA-EN-P /-C, S/S-C * * * * Conventional X X X X X X X X X X X X X X X X X X Electronic EI Operating Limits Hz, Hz, pick-up [x Us] / Hz dropout [x Us] DC (conventional) DC (electronic) pick-up [x Us] dropout [x Us] pick-up [x Us].. dropout [x Us]. Coil Consumption Hz, Hz, pick-up [VA/W] / / / / / / / / / Hz hold-in [VA/W] /. /. / / /. /. /. / DC (conventional) DC (electronic) pick-up [W] cold., warm hold-in [W] cold., warm pick-up (avg/peak) [W] / / / hold-in [W]... Operating Times closing delay [ms] AC opening delay [ms] With RC module opening delay [ms] DC closing delay [ms] (conventional) opening delay [ms] With integ. diode With external diode opening delay [ms] V V opening delay [ms] DC (electronic) closing delay [ms] opening delay [ms] Max. Ripple ± % Min. OFF time [ms] For,,, and V DC coils /-D, S-D / / Conventional X X Coil Type Electronic EI X X X X X X X X X Operating Limits Hz, Hz, pick-up [x Us] / Hz dropout [x Us] DC control pick-up [x Us] dropout [x Us] Coil Consumption Hz, Hz, pick-up [VA/W] / / / / / Hz hold-in [VA/W] / / / / DC control pick-up [W] hold-in [W] Operating Times AC closing delay [ms] opening delay [ms] With RC module opening delay [ms] DC closing delay [ms] opening delay [ms] Integrated diode opening delay [ms] External diode opening delay [ms] Electronic coil drives are designed to minimize power requirements, but this control may exhibit a higher inrush ( W, < ms) when energizing. This must be taken into account for the proper sizing of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your local Rockwell Automation sales office or Allen-Bradley distributor for detailed information.
20 Bulletin /-K, /-C, /-D, S/S-C, S-D Auxiliary Contacts, Auxiliary Contact Blocks, and Pneumatic Timers Switching of AC Loads Internal -K -C, S-C -D, S-D Internal Frontmounted Frontmounted Frontmounted (Bifurcated) Sidemounted Convent'l Side-mounted Bifurcated Electronically compatible at C [A]. AC- I th at C [A] at V AC- at rated voltage of V [A]. /V [A]. V [A]. V [A]... ( ma) V [A] at V [A].. V V [A]... V [A] V [A].... Switching of DC Loads DC- L/R< ms resistive loads at V DC [A] V DC [A].. V DC [A] V DC [A] V DC [A] DC- L/R< ms inductive loads with economy resistor in series at V DC [A] V DC [A]... V DC [A]... V DC [A] V DC [A] DC- switching electromagnets at V DC [A]... V DC [A]... ( ma) V DC [A] at V DC [A] V V DC [A] Fuse gg Short-circuit protection with no welding of contacts per IEC -- [A] [A] Protective Separation per IEC -, Annex N Min. switching capacity according to IEC -- V/ ma V/ ma between load and auxiliary circuit V between load and auxiliary circuit V between load and auxiliary circuit V V/ ma V/ ma V/ ma V/ ma V/ ma Failure rate V/ ma ( Mio. ops.) <- (less than failure to Mio. operations) V/ ma Load Carrying Capacity per UL/CSA Rated voltage AC [V] max. max. max. max. General Continuous rating C [A]. purpose Heavy pilot duty Switching capacity AC [A] A B A. (A ) Rated voltage DC [V] max. max. max. max. Switching capacity DC [A] Q P Q Q Standard pilot duty (P ) Standard pilot duty (Q ). Publication A-CAA-EN-P -
21 Bulletin /-K, /-C, /-D, S/S-C, S-D General -K -C, S-C -D, S-D Rated Isolation Voltage U i IEC [V] UL, CSA [V] Rated Impulse Voltage Withstand U imp [kv] Rated Voltage U e AC / Hz [V],,,,,,,,,,,,,,,,,,,,,, DC [V],,,,,,,,,,,, Insulation Class of the Coil Class F per IEC Class insulation system per UL Class F per IEC Class B per VDE, Table Rated coil frequency AC / Hz, DC AC / Hz, DC AC Hz, / Hz, DC Ambient Temperature Storage [ C] Operation at rated voltage [ C] at C % current reduction against C values Climatic Withstand IEC -- IEC -- / - / - IEC -- Max. Altitude of Installation Site [m] NN, per IEC - NN, per IEC - NN, per IEC - Protection Class IPX IPX IP IEC / DIN Single contactor cover IP IEC / DIN Contactor with frame terminal block IP IEC / DIN Auxiliary contact IPX IP IEC / DIN Protection against Accidental Contact Finger and back-of-hand proof per VDE, part Finger and back-of-hand proof per VDE, part Resistance to Shock IEC - IEC -- IEC -- Resistance to Vibration IEC - IEC -- IEC -- Mechanically Linked Contacts IEC --, Annex L Mirror Contacts IEC - Annex F Standards Compliance Certifications -K (on main device) -K + -KF IEC/EN -/--/--; UL ; CSA.. No. CE, culus CCC - / S-C C + -FA/- FB/-FC, (except L, L), - / S-C C + -FAB/-FBB/- FCB - / S-C C + -FA/- FB/-FC, (except L, L), - / S-C C + -SA/SB, - / S-C C + -FAB/-FBB/- FCB IEC/EN -/--/--; UL ; CSA.. No. CE, culus, CCC -D + x -DS- S-D + x S-DS- IEC/EN -/--/--; UL ; CSA.. No. CE, culus, CCC - Publication A-CAA-EN-P
22 Bulletin -K/-K, -C/-C, -D/-D, -G Electrical Life in Utilization Category Bulletin -C/-C IEC contactors are designed for superior performance in a wide variety of applications. When selecting IEC products, the user must give consideration to the specific load, utilization category and required electrical life of the application. The life-load curves shown here are based on Rockwell Automation tests according to the requirements defined in IEC --. Since contact life in application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. To find the contactor s estimated electrical life, follow these guidelines:. Identify the appropriate utilization category from the table below.. Choose the graph for the utilization category selected.. Locate the intersection of the life-load curve for the appropriate contactor with the application s operational current (I e ) found on the horizontal axis.. Read the estimated contact life along the vertical axis. Contact Life for Mixed Utilization Categories AC- and AC-: In many applications, the utilization category cannot be defined as either purely AC- or AC-. In those applications, the electrical life of the contactor can be estimated from the following equation: Lmixed = Lac/[ + Pac*(Lac/Lac )], where: Lmixed = Approximate contact life in operations for a mixed AC-/AC- utilization category application Lac = Approximate contact life in operations for a pure AC- utilization category (from the AC- life-load curves) Lac = Approximate contact life in operations for a pure AC- utilization category (from the AC- life-load curves) Pac = Percentage of AC- operations AC- AC- AC- AC- AC- Test Conditions Resistance Furnaces: Non inductive or slightly inductive loads Slip-ring motors: Starting and reversing Squirrel-cage motors: Starting and stopping of running motors Squirrel-cage motors: Starting, plugging, inching Soleniods: Contactors, valves and lifting magnets I e < A I e > A I e < A I e > A Making Breaking I/I e U/U e cosφ I c /I e U r /U e cosφ I e Rated operational current I Making Current U e Rated voltage Ic Breaking Current U r Recovery voltage U Off-load voltage Plugging is understood as stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. Inching (jogging) is understood as energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. - Publication A-CAA-EN-P
23 Bulletin -C/-C Life-Load Curves AC- C Non- or slightly inductive loads, resistance furnaces; U e = V E+ C C C C C C C C C C C C / C Operating cycles E+ C E+ AC- Switching of slip-ring motors; U e = V E+ C C C C C C C Rated operating current I e AC- [A] C C C C Operating cycles E+ E+ Rated operating current I e AC- [A] - Publication A-CAA-EN-P
24 Bulletin -C/-C Life-Load Curves AC- Switching of squirrel-cage motors while starting; U e = V E+ C C C C C C C C C C C Operating Cycles E+ E+ Rated Operating Current I e AC- [A] Switching of squirrel-cage motors while starting; U e = V E+ C C C C C C C C C C C Operating Cycles E+ E+ Rated Operating Current I e AC- [A] Publication A-CAA-EN-P -
25 Bulletin -C/-C Life-Load Curves AC- Switching of squirrel-cage motors while starting; U e = V E+ C C C C C C C C C C C Operating Cycles E+ E+ AC- Switching of squirrel-cage motors; U e = V Operating Cycles E+ E+ E+ C C C C C C C C C C Rated Operational Current I e AC- [A] C E+ Rated Operating Current I e AC- [A] - Publication A-CAA-EN-P
26 Bulletin -C/-C Life-Load Curves AC- & AC- % AC- Mixed operation of squirrel-cage motors; U e = V E+ C C C C C C C C C C C Operating Cycles E+ E+ Rated Operating Current I e AC- / AC- [A] Heavy Duty Starting and Regular Short-time Operation Bulletin -C Contactors C/C/C C C/C C C/C/C C Maximum Starting Time/Loading Time [s] Starting Current/Short Time Current [A] Publication A-CAA-EN-P -
27 Bulletin -C/-C Maximum Operating Rates AC- C Non- or slilghtly inductive loads, resistance furnaces; U e = V E+ Permissible switching rate [ops/hr] E+ E+ E+ E+ C/C/C/C C/C/C E+ C/C C/ C/C E+ P/Pn [%] AC- Stepping of slip-ring motors; U e = V E+ Permissible switching rate [ops/hr] E+ C/C/C C/C/C/C C/C C/C E+ P/Pn [%] - Publication A-CAA-EN-P
28 Bulletin -C/-C Maximum Operating Rates AC- Switching of squirrel-cage motors while starting; U e = V Relative operating time %, Starting time t A =. s E+ Permissible switching rate [ops/hr] E+ C/C/C C/C/C/C C/C/C/C E+ AC- Inching of squirrel-cage motors; U e = V Starting time t A =. s E+ P/Pn [%] Permissible switching rate [ops/hr] E+ C C C C/C C/C/C C C/C E+ P/Pn [%] Publication A-CAA-EN-P -
Ratings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationBulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide
Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................
More informationConnection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K
Bulletin Overview/Product Selection Προδυχτ Σελεχτιον Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUA Red Cover and
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationThe CWC0 compact contactors are offered as a complete solution for switching and controlling motors.
Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationMiniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays
Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationDescription Basic devices with positive operation contacts
Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationBlock Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4
/0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationXT IEC Power Control Miniature Controls
Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationNZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data
Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More information3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching
Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL
More informationType: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationNEMA Contactor and Starter Specifications
Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationNS..S contactor relays - with spring terminals AC operated
NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More informationIndustrial Controls. Catalog IC SIRIUS. Answers for industry.
Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationElectronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact
Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationIGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards
APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationSolid-state Contactor Specifications
Technical Data Solid-state Contactor Specifications Bulletin Number 156 Topic Page Topic Page Catalog Number Explanation 2 Dual- and Three-phase Devices 25 Single-phase Devices 3 Product Selection 25 Product
More informationElectronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationSupplemental Motor Protection Devices Table of Contents
Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -
More informationBulletin 700-R -RM Sealed Switch Relays
Bulletin 700-R -RM Sealed Switch Relays Bulletin 700 R, RM Sealed Switch Relays Sealed contacts Extremely long mechanical and electrical life Hazardous locations Class 1, Div Groups A, B, C, D Harsh environments
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationElectronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationPluggable interface relays CR-U Universal relays
Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationLC2D09BL REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationSmall but rugged DRAFT
Series C8 and CT8 Starters n ingenious miniature contactor and starter system Sprecher + Schuh s New C8 Series of miniature contactors and starters provide an extremely compact and reliable method of controlling
More informationMini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU
/0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationLC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationLC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More information