Output of three-phase motors at 50 Hz and 400 V

Size: px
Start display at page:

Download "Output of three-phase motors at 50 Hz and 400 V"

Transcription

1 RT0, RH Coupling Relays (Interfaces) Description DC operation IEC and EN (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements of the connection to solid-state control equipment. Coupling relays have a low power consumption, an extended working range of the solenoid coil (0.7 to.25 x s ) as well as an integrated surge suppression against switching voltages (exceptions: RT0.-HB4. and RH..-HB40). Onto RT0. and RH coupling relays of size S00, auxiliary switch blocks cannot be fitted. Onto size S0, two singlepole auxiliary switch blocks can be snapped on. RT0 Coupling Relays (Interfaces) for Switching Motors Selection and ordering data Surge suppressor Ratings C-2 and C- duty T u : to 0 C Operational current I e at 400 V Output of three-phase motors at 50 Hz and 20 V uxiliary contacts RT0 coupling relays Weight approx. Identification Design Order No. Price number kw kw kw kw NO NC Preferred type With screw connection for screw and snap-on mounting onto 5 mm standard rail DC operation Size S00 Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 2. W at 24 V (no auxiliary block mountable) 400 V 500 V 90 V unit kg RT0.-.B4. RT0 2.-KB40 Diode, varistor RT0 5-HB4 0.2 or RC element 0 RT0 5-HB42 mountable Built-in RT0 5-JB4 0.2 diode 0 RT0 5-JB42 Built-in RT0 5-KB4 0.2 varistor 0 RT0 5-KB42 Diode, varistor RT0 -HB4 0.2 or RC element 0 RT0 -HB42 mountable Built-in RT0 -JB4 0.2 diode 0 RT0 -JB42 Built-in RT0 -KB4 0.2 varistor 0 RT0 -KB42 Diode, varistor RT0 7-HB4 0.2 or RC element 0 RT0 7-HB42 mountable Built-in RT0 7-JB4 0.2 diode 0 RT0 7-JB42 Built-in RT0 7-KB4 0.2 varistor 0 RT0 7-KB42 Size S0 Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 4.2 W at 24 V (two single-pole auxiliary switch blocks mountable) Built-on varistor RT0 24-KB RT0 25-KB RT0 2-KB40 0. ccessories, see page /. Technical data, see page /0. Internal circuit diagrams, see page /. Dimensions, see page /52. /27

2 RT0 Coupling Relays (Interfaces) for Switching Motors Selection and ordering data CGE CLMP Surge suppressor Ratings C-2 and C- duty T u : to 0 C Operational current Output of three-phase motors at 50 Hz and I e at 400 V 20 V 400 V 500 V 90 V uxiliary contacts RT0 coupling relays Weight approx. Identification Design Order No. Price number kw kw kw kw NO NC Preferred type unit kg With Cage Clamp connection for screw and snap-on mounting onto 5 mm standard rail DC operation Size S00 Cage Clamp connection for all terminals Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 2. W at 24 V (no auxiliary block mountable) RT0 5-2JB4 Diode, varistor RT0 5-2HB4 0.2 or RC element 0 RT0 5-2HB42 mountable RT0 2-KB40 Built-in RT0 5-2JB4 0.2 diode 0 RT0 5-2JB42 Built-in RT0 5-2KB4 0.2 varistor 0 RT0 5-2KB42 Diode, varistor RT0-2HB4 0.2 or RC element 0 RT0-2HB42 mountable Built-in RT0-2JB4 0.2 diode 0 RT0-2JB42 Built-in RT0-2KB4 0.2 varistor 0 RT0-2KB42 Diode, varistor RT0 7-2HB4 0.2 or RC element 0 RT0 7-2HB42 mountable Built-in RT0 7-2JB4 0.2 diode 0 RT0 7-2JB42 Built-in RT0 7-2KB4 0.2 varistor 0 RT0 7-2KB42 Size S0 Cage Clamp connection for auxiliary and coil terminals Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 4.2 W at 24 V (two single-pole auxiliary switch blocks mountable) Built-on RT0 24-KB varistor RT0 25-KB RT0 2-KB ccessories, see page /. Technical data, see page /0. Description, see page /27. Internal circuit diagrams, see page /. Dimensions, see page /52. /28

3 RH Coupling Relays (Interfaces) for Switching uxiliary Circuits Selection and ordering data Surge suppressor Rated operational current I e /C-5/C-4 at 20 V 400 V 500 V 90 V With screw connection for screw and snap-on mounting onto 5 mm standard rail RH..-.B40 DC operation size S00 Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 2. W at 24 V (no auxiliary block mountable) Contacts RH coupling relays Weight approx. Identification Design Order No. Price number acc. to EN 50 0 NO NC Preferred type unit kg Diode, varistor 2 40 E 4 RH 40-HB or RC element E RH -HB40 mountable 22 E 2 2 RH 22-HB40 Built-in diode Built-in varistor 2 40 E 4 RH 40-JB E RH -JB40 22 E 2 2 RH 22-JB E 4 RH 40-KB E RH -KB40 22 E 2 2 RH 22-KB40 With Cage Clamp connection for screw and snap-on mounting onto 5 mm standard rail DC operation size S00 Cage Clamp connection for all terminals Rated control supply voltage s = 24 V DC, coil voltage tolerance 7 to 2 V Power consumption of the solenoid coils 2. W at 24 V (no auxiliary block mountable) RH 22-2KB40 Diode, varistor 2 40 E 4 RH 40-2HB or RC element E RH -2HB40 mountable 22 E 2 2 RH 22-2HB40 CGE CLMP Built-in diode Built-in varistor 2 40 E 4 RH 40-2JB E RH -2JB40 22 E 2 2 RH 22-2JB E 4 RH 40-2KB E RH -2KB40 22 E 2 2 RH 22-2KB40 ccessories, see page /. Technical data, see page /0. Description, see page /27. Internal circuit diagrams, see page /. Dimensions, see page /52. /29

4 RT0, RH Coupling Relays (Interfaces) Technical data ny technical data not given in the table below are identical to those of the RH contactor relays (from page /5 on) and the RT0 contactor relays for switching motors in Part. The coupling relays size S00 (RH and RT0.) cannot be expanded by auxiliary switch blocks. Two single-pole auxiliary switch blocks can be mounted onto the RT0 2. coupling relay (see Part ). Contactor Type Size RT0.-HB4. RH..-HB40 S00 RT0.-JB4. RH..-JB40 S00 RT0.-KB4. RH..-KB40 S00 RT0 2.-KB40 S0 Coil voltage tolerance 0.7 to.5 x s q 7 to 2 V Power consumption of the coils (with cold coil) at s 7 V.2 W.2 W.2 W 2. W 24 V 2. W 2. W 2. W 4.2 W closing = closed 0 V. W. W. W. W Permissible residual current of the electronics (with 0 signal) 24V < 0 m x < 0 m x < 0 m x < m x s s s 24V s Surge suppression of the coil without overvoltage protection with diode with varistor with varistor Operating times of the coupling relays Closing at 7 V ON-delay OFF-delay NO NC 40 to 20 ms 0 to 70 ms 40 to 20 ms 0 to 70 ms 40 to 20 ms 0 to 70 ms 9 to 270 ms 8 to 250 ms at 24 V ON-delay OFF-delay NO NC 0 to 0 ms 20 to 40 ms 0 to 0 ms 20 to 40 ms 0 to 0 ms 20 to 40 ms 4 to 87 ms 55 to 78 ms at 0 V ON-delay OFF-delay NO NC 20 to 50 ms 5 to 0 ms 20 to 50 ms 5 to 0 ms 20 to 50 ms 5 to 0 ms 5 to 4 ms 45 to 5 ms Opening at 7 to 0 V OFF-delay ON-delay NO NC 7 to 7 ms 22 to 0 ms 40 to 0 ms 0 to 70 ms 7 to 7 ms 22 to 0 ms 8 to 9 ms 24 to 25 ms pright mounting position Please enquire /0

5 RT0, RH Coupling Relays (Interfaces) Internal circuit diagrams DC operation to be connected to the solenoid coil terminal of L+. RT0. coupling relays for switching motors, size S00 Terminal designations acc. to EN (no auxiliary block can be snapped on) Surge suppressor mountable NO NC Ident. No.: 0E 0E (+) 5 2 (-) NSK-25 (+) (-) NSK-2 RH coupling relays for auxiliary circuits, size S00 Terminal designations acc. to EN 50 0 (no auxiliary block can be snapped on) Surge suppressor mountable 4 NO NO + NC Ident. No.: 40E E (+) (-) NSK-22 (+) (-) NSK-2 2 NO + 2 NC 22E (+) (-) NSK-24 Diode built-in NO Ident. No.: 0E NC 0E Diode built-in 4 NO Ident. No.: 40E NO + NC E 2 NO + 2 NC 22E (+) 2 (-) NSK-29 (+) 2 (-) NSK-0 (+) (-) NSK-27 (+) (-) NSK-08 (+) (-) NSK-28 Varistor built-in NO Ident. No.: 0E NC 0E Varistor built-in 4 NO Ident. No.: 40E NO + NC E 2 NO + 2 NC 22E (+) 2 (-) NSK-4 (+) 2 (-) NSK-5 (+) (-) NSK- (+) (-) NSK-2 (+) (-) NSK- RT0 2. coupling relays for switching motors, size S0 (two single-pole auxiliary switch blocks can be snapped on) Varistor built-on Surge suppressor for size S00 (plug-in direction coded) Diode Varistor RC element Diode assembly Diode with LED Varistor with LED NSK-09 NSK-905 NSK-907 /

6 RT0, RH Coupling Relays (Interfaces) Position of terminals Size S00 RT0. coupling relays NO Ident. No.: 0E NC NSK NSK-74 RH coupling relays 4 NO Ident. No.: 40E NO + NC E 2 NO + 2 NC 22E NSK NSK NSK-557 Size S0 RT0 2. coupling relay /2

7 RH9 24, TX7 090 Interfaces for Mounting onto Contactors Description DC operation IEC and DIN VDE 00 The interfaces are suitable for use in any climate. They are safe from touch according to DIN VDE 00 Part 00. The terminal designations are in accordance with EN Design System compatible actuation with 24 V DC, coil voltage tolerance 7 V to 0 V. Small power consumption of the coils in accordance with the technical data of the electronic systems. n LED indicates the switching condition. Surge suppression The TX D and RH9 24-GP interfaces have an integrated varistor for the contactor coil to be operated. Mounting The RH9 24-GP interfaces are connected directly to the coil and the TX7 090 interfaces are snapped onto the auxiliary switch blocks laterally. Selection and ordering data DC operation with screw connection For contactor Contacts Design Order No. Price Weight approx. Packing Size Type Preferred type unit kg nits Interface for direct mounting onto the contactor coil RH9 24-GP S0 to S NO with surge suppressor RH9 24-GP 0.04 Interface for lateral snapping onto the auxiliary switch TX D to 4 TF4 to TF9, TK48 to TK5 NO with surge suppressor TX D /

8 General data Rated insulation voltage i (pollution degree ) V 00 Degree of protection Terminals Housing IP 20 IP 40 Permissible ambient temperature during operation when stored C C 25 to to +80 Conductor cross-sections solid finely stranded with end sleeve terminal screws mm 2 mm 2 2 x (0.5 to 2.5) 2 x (0.5 to.5) M Short-circuit protection (weld-free protection at I k W k) Fuses, utilization category gl/gg NH DIZED NEOZED RH9 24, TX7 090 Interfaces for Mounting onto Contactors Technical data Type N Type 5SB Type 5SE Control circuit Rated control supply voltage s DC V 24 Coil voltage tolerance DC V 7 to 0 Power consumption of the coils at s W 0.5 Current input m 20 Release voltage V 4 Function indicator LED yellow Snubber Varistor Load circuit Mechanical endurance Electrical endurance at I e Operating cycles Operating cycles 20 x 0 x 0 5 Operating frequency /h 5000 operating cycles Make-time ms approx. 7 Break-time ms approx. 4 Bounce time ms approx. 2 Contact material gsno Operational voltage V 24 to 250 C/DC Permissible residual current of the electronics (with 0 signal) m 2.5 Rated currents ) Conventional thermal current I th Rated operational current I e acc. to utilization categories (DIN VDE 00) Operational current with resistive load acc. to DIN VDE 045 (relay standard) and DIN VDE 00 at 24 V 0 V 20 V at 24 V 0 V 20 V C-5 DC C-2 DC ) Capacitive loads may cause micro welding at the contacts. /4

9 RH9 24, TX7 090 Interfaces for Mounting onto Contactors Internal circuit diagrams RH9 24-GP with surge suppression $ L B+ B2- N TX D with surge suppression X2 2 X NO B+ % NO4 B2- NSK-72b 2 NSK-8057 $ Interface % Contactor Typical circuits RH9 24-GP with surge suppression TX D with surge suppression NSK-844 L- NO 4 X2 2 L+ B + NO B2 - X 2 $ Interface % Contactor L N /5

10 Modular Terminal-Type Interfaces TX7 002, TX7 00 Coupling Relays and Optocouplers Description C and DC operation DIN VDE 00 Part, DIN VDE 045, DIN VDE 00 and EN The input and output interfaces differ in the location of terminals and LEDs. blank label is fitted on each interface to enable identification of the devices. Small power consumption of the coils matches the technical data of the electronics systems. The contact of an optocoupler is a semiconductor, which is not subject to wear. Welding is not possible. Surge suppression The connection of inductive loads with a surge suppressor increases the service life of the coupling relays. Mounting For snapping onto horizontal and vertical standard mounting rail. With vertical rail and close mounting the permissible ambient temperature T u = 40 C. Can be mounted in any position. Typical circuit Selection and ordering data C and DC operation for snap-on mounting onto 5 mm standard rail Rated control Pack. supply voltage s Contacts (version) Width Order No. Price Weight approx. 50/0 Hz C NO CO mm Preferred type unit kg nits TX7 002 and TX7 00 coupling relays Output interfaces with screw connection TX V C/DC.5 TX7 002-B V C/DC (hard gold-plated) TX7 002-B02 TX7 002 optocouplers TX V C/DC 7.5 TX7 002-BB V C/DC TX7 002-BF00 24 V C/DC TX7 002-CB V C/DC 2 (hard goldplated) TX7 002-FB02 Output interfaces with Cage Clamp connection 24 V C/DC.5 TX7 00-B Input interfaces with screw connection 24 V C/DC 0 V C/DC 20 V ) C/DC 20 V ) C/DC 20 V C/DC (hard goldplated) Output interfaces with screw connection.5 TX B00 TX E00.5 TX F00 TX F TX BF V DC (semiconductor) 2.5 TX7 002-B TX7 002-B ccessories Input interfaces with screw connection 24 V C/DC (semiconductor) 2.5 TX B to 240 V C (semiconductor) 2.5 TX G Connecting lead for TX7 002, TX terminals with leads, blue TX B ) Observe max. permissible conductor length See page /7. / Only supplied in packs.

11 Modular Terminal-Type Interfaces TX7 002, TX7 00 Coupling Relays Technical data General data Rated insulation voltage i (pollution degree ) V 00 Degree of protection for TX Housing Relay Short-circuit protection (weld-free protection at I k W k) Fuses, utilization category gl/gg 4 Permissible ambient temperature during operation when stored C C 25 to to +80 IP 20 IP 40 IP 20 IP 7 Conductor cross-sections Screw connection: solid finely stranded with or without end sleeve Terminal screws Cage Clamp connection (at TX7 00): solid, finely stranded finely stranded with end sleeve mm 2 x (0.25 to 4) mm 2 x (0.5 to 2.5) M mm 2 x (0.08 to 2.5) mm 2 x (0.25 to 2.5) Control circuit Type TX7 002-/TX7 00- B02 B00 BB00 FB02 CB00 2B00 2E00 BF00 2BF02 2F00 2F05 Working range 0.8 to.25 x s 0.8 to. x s Power consumption of the coils at s W Release voltage % of s W 0% W 25% Max. permissible conductor length C m (min. cross-section: 0.75 mm 2 ) DC m 2000 Permissible residual current of the electronics (with 0 signal) m Operating times at s Function indicator ON-delay OFF-delay ms ms < 8 < 0 LED yellow Load side Rated currents ) Conventional thermal current I th Rated operational current I e acc. to utilization categories (DIN VDE 00) (TX7 002-CB00: C-5, I e =2) C-5 Operational current with resistive load acc. to DIN VDE 045 (relay standard) and DIN VDE V 0 V 20 V 24 V 0 V 20 V Note: The connection of a suppression circuit to inductive loads increases the service life of the coupling relays. C-2 Operational voltage C/DC V 24 to 250 Min. contact loading for TX , 24 V C/DC, 0 m TX , TX F05 DC DC-2 Min. contact loading for TX V C/DC, 0. m Mechanical endurance 20 x 0 operating cycles Electrical endurance at I e x 0 5 operating cycles Operating frequency /h 5000 operating cycles Contact material at TX g/ni 0.5 hard gold-plated Power limit/hard gold plating at TX V/20 m ) Capacitive loads may cause micro welding at the contacts. 2) TX7 002-FB02 without safe isolation acc. to DIN VDE 00 Part 0. /7

12 Modular Terminal-Type Interfaces TX7 002 Optocouplers Technical data General data Rated insulation voltage i (pollution degree ) Optoelectronic coupler for safe isolation acc. to DIN VDE 0884 Conductor cross-sections solid finely stranded with or without end sleeve Terminal screws V 00 V to 00 mm 2 x (0.25 to 4) mm 2 x (0.5 to 2.5) M Derating diagram for TX7 002-B0 Load current as a function of the ambient temperature T u Permissible ambient temperature during operation when stored C C 20 to to +80 Control circuit Type TX B00 B0 4B00 4G00 Working range DC DC C/DC C V 7 to 0 7 to 0 7 to 0 88 to 24 V Current input m < 8 at 7 V DC < 5 at 7 V DC < 0 at 7 V C/DC < 9 at 88 V C < 20 at 24 V DC < 7 at 24 V DC < 4 at 24 V C/DC < 24 at 20 V C < 22 at 0 V DC < 8.5 at 0 V DC < 8 at 0 V C/DC < 28 at 24 V C Release voltage V > 5 > 8 > 5 > 40 Operating times ms < 0 < 0. < < 8 ON-delay at 7 V DC at 7 V DC at 7 V C/DC at 88 V C 24 V DC 24 V DC 24 V C/DC < 20 0 V DC 0 V DC 0 V C/DC at 20 V C < 22 at 24 V C OFF-delay ms < 0 < 0. < 8 < 0 at 7 V DC at 7 V DC at 7 V C/DC at 88 V C 24 V DC 24 V DC < 25 < 20 0 V DC 0 V DC at 24 V C/DC at 20 V C < 0 < 25 at 0 V C/DC at 24 V C Function indicator LED yellow LED yellow LED yellow LED yellow Max. permissible conductor length C m (min. cross-section: 0.75 mm 2 ) DC m Load side Type TX B00 B0 4B00 4G00 Rated operational current I e.8.5 (see derating diagram) 00 m 00 m Short time load rating ms Contacts NO contact NO contact NO contact NO contact Triac Transistor Transistor Transistor Operational voltage ) (Working range) r.m.s. 50/0 Hz C 48 to 24 V DC w 0 V DC w 0 V DC w 0 V Minimum load current m 0 Conductive voltage drop V w.5 w. w.7 w 0. Residual current < 5 m < 0. m < 0. m µ of the electronics (with 0 signal) Operating frequency Hz at I e Hz at I e 5 Hz 5 Hz ) Observe minimal switching voltage with TX7 002-B00. /8

13 Modular Terminal-Type Interfaces TX7 002, TX7 00 Coupling Relays and Optocouplers Internal circuit diagrams Coupling relays Terminal designations acc. to EN TX B. 00 -B02-2F05 TX7 00-B00 -CB00 2 -FB02 2-2BF02 NS NS NS NSK Optocouplers Terminal designations acc. to EN TX7 002-B00 -B0-4B00-4G0. NS NS NS NS Position of terminals Coupling relays Output interfaces TX7 002-B0. TX7 00-B00 -B. 00 -CB00 -FB02 Input interfaces TX TX BF02 Optocouplers Output interfaces TX7 002-B0. Input interfaces TX /9

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6 Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram

More information

Solid-State Soft Starters

Solid-State Soft Starters Selection and ordering data Rated operational voltage U e V Soft starters for three-phase asynchronous motors 3RW30 25-1B14 3RW30 35-1B14 t ambient temperature 40 C Size Order No. Price Weight Pack. Rated

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

2 or 4 pole changeover contact Plug-in/Faston 187

2 or 4 pole changeover contact Plug-in/Faston 187 56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

SIRIUS/SIKOSTART Soft Starters For Standard Applications

SIRIUS/SIKOSTART Soft Starters For Standard Applications Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

3TX7, 3RS18 Coupling Relays

3TX7, 3RS18 Coupling Relays TX7, RS18 Coupling Relays TX7 Coupling Relays, Narrow Design Relay couplers Siemens AG 2010 Application AC and DC operation EN 60947, EN 60664-1 and EN 50005. In the coupling links in double-decker design,

More information

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250 Power Electronics POWERSWITCH Semiconductor Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250 Power Electronics POWERSWITCH Solid-State Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard

More information

Short-circuit-proof switching amplifier for inductive loads up to 10 A

Short-circuit-proof switching amplifier for inductive loads up to 10 A MICROOPTO Overview Short-circuit-proof switching amplifier for inductive loads up to 10 Powerful, compact solid-state relay with error signalling contact The MICROOPTO family offers the customer high-quality

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry. Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction

More information

62.22 Copper side view

62.22 Copper side view 62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection 65 Power relays 20-30 65 20 Power relays 1 NO + 1 NC (SPST-NO + SPST-NC) 65.31 Flange mount Faston 250 connections 65.61 PCB mount C coils & DC coils Cadmium Free option available 65.31 65.61 20 rated

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

Relay modules, Relay sockets, Plug relays

Relay modules, Relay sockets, Plug relays , Relay sockets, Plug relays General information Relay input side (coil) Single relays housed in slim, rail mounting enclosures taking up the minimum of space. Multiple relays (up to 24) in compact rail

More information

Solid-State Switching Devices

Solid-State Switching Devices SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay 62 Series - Power relays 16 62 SERIES Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages, approvals... 224 R100.xx semiconductor contactors, single-phase Ordering details... 225 Technical data... 228 Dimensional drawings...

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

RELOG. All-or-nothing Relay

RELOG. All-or-nothing Relay RELOG All-or-nothing Relay Table of Content Page RELOG a system with contact components used in control engineering 3 Survey of the 'All-or-nothing relays' device program included in the RELOG system 3

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Datasheet - PROTECT-IE-02

Datasheet - PROTECT-IE-02 Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

62 Series - Power relays 16 A. Features / /

62 Series - Power relays 16 A. Features / / 6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Electronic timer CT-SDE

Electronic timer CT-SDE CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

38 Series - Relay interface modules A. Features /

38 Series - Relay interface modules A. Features / Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks. 2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346 314 PHOENIX CONTACT PHOENIX CONTACT 315 RIF-0 for miniature and solid-state relays Page 328 RIF-1 for miniature and solid-state relays Page 334 RIF-2 for industrial relays Page 342 RIF-3 for octal relays

More information

SIGMA Terminal components

SIGMA Terminal components SIGMA Terminal components Optocouplers Content Terminal components Description, Certifications, Authorizations... 151 Ordering details R1000 / R2000 / R 1500... 152 Ordering details - Series RT, PT, MT...

More information

Power Supplies. 11/2 Introduction. 4AV Non-Stabilized. Power Supplies

Power Supplies. 11/2 Introduction. 4AV Non-Stabilized. Power Supplies Siemens AG 009 Power Supplies / Introduction AV Non-Stabilized Power Supplies Filtered for Supply of Electronic Controls General data / - Overview / - Design / - Function / - Technical specifications AV,

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Description Basic devices with positive operation contacts

Description Basic devices with positive operation contacts Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

PSR-SCP- 24DC/ESD/5X1/1X2/300

PSR-SCP- 24DC/ESD/5X1/1X2/300 Extract from the online catalog PSR-SCP- 24DC/ESD/5X1/1X2/300 Order No.: 2981428 Safety relay with adjustable delay time 0-300 s, screw version Commercial data EAN 4017918975227 Pack 1 pcs. Customs tariff

More information

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................

More information

SOLID STATE RELAY RATINGS

SOLID STATE RELAY RATINGS Solid State Relays SOLID STATE RELAY RATINGS PART NUMBER HPR48A25 HPR48A50 HPR48A75 3PSS60A75 HPR48D25 HPR48D50 HPR48D75 Rated operational current AC51 @ Ta=25 C 25 AMPS rms 50 AMPS rms 75 AMPS rms 75

More information

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1 Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information