1 Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and DC Full-voltage non-reversing and reversing contactors,, and A contactors rated at V IPX finger protection Optional integrated surge suppressor Compatible with Bulletin -K bimetallic overload relay Mirror contacts per IEC -- and mechanically linked contacts per IEC -- on main unit Your order must include: cat. no. (with coil voltage code) of the mini contactor specified and, if required, cat. no. of any accessories Allen-Bradley Bulletin -K miniature contactors are designed for commercial and light industrial applications where panel space is at a premium. These miniature devices, while mm wide, are shallower and have less panel depth requirements than standard IEC contactors. The miniature contactors have been designed with flexibility in mind. They are available with AC or DC operating coils, several contact ratings, and optional - or -pole adder decks in a variety of auxiliary contact configurations. Rated Operational Ratings for switching AC motors - AC-, AC-, AC- Auxiliary Contacts Current I e [A] -Phase kw ( Hz) Hp ( Hz) C -Phase -Phase AC- AC- V /V V V V V V V V V N.O. N.C. Screw Terminals.... / -/ -/ / -/... / -/ -/ Spring Clamp Terminals.... / / -/ -/. / May be ordered in package quantities of. Add letter M to the end of the cat. no. Example: -KZJM. The Cat. No. as listed is incomplete. Select a Coil Voltage Code from page - to complete the Cat. No. Example: V DC: Cat. No. -K becomes Cat. No. -KZJ. -Pole AC- and DC-Operated Contactors Rated Operational Current I e [A] Ratings for switching AC motors - AC-, AC- -Phase kw ( Hz) Hp ( Hz) Standards Compliance IEC/EN -,--,--,-- UL CSA.. No. NF F - Meets the material restrictions for European Directive //IEC-EU-RoHS Certifications CE Marked culus Listed (File No. E, Guide NLDX, NLDX) CCC Pkg. Qty. Cat. No. -K -K -K -K -K -K -KR -KR -KR -KR Contact Configuration, Main Pole C -Phase -Phase Pkg. AC- AC- V /V V V V V V V V V N.O. N.C. Qty. Cat. No. -K.... / -/ -/ -K -K -K / -/ -K -K -K... / -/ -/ -K -K May be ordered in package quantities of. Add letter M to the end of the cat. no. Example: -KZJM. The Cat. No. as listed is incomplete. Select a Coil Voltage Code from page - to complete the Cat. No. Example: V DC: Cat. No. -K becomes Cat. No. -KZJ. Table of Contents Product Selection... this page Accessories Approximate Dimensions Publication A-CAA-EN-P

2 Reversing AC- and DC-Operated Contactors Rated Operational Current I e [A] -Phase kw ( Hz) Ratings for switching AC motors - AC-, AC-, AC- Hp ( Hz) Bulletin -K, -K IEC Miniature Contactors Product Selection Auxiliary Contacts per Contactor C -Phase -Phase AC- AC- V /V V V V V V V V V N.O. N.C. Cat. No / -/ -K -K... -/ -/ -K Used for electrical interlocking The Cat. No. as listed is incomplete. Select a standard Coil Voltage Code from this page to complete the Cat. No. Example: V, / Hz: Cat. No. -K becomes Cat. No. -KKF. Bulletin -K reversing contactors are factory assembled and include contactors, mechanical interlock (Cat. No. -KMCH) and wiring kit (Cat. No. -KPR) for power and control circuit (electrical interlock). Wiring schematic see -KPR. Coil Voltage Code for screw type terminal versions The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: V, Hz: Cat. No. -K becomes Cat. No.-KD. AC Voltages [V] Hz D Hz D B VC / Hz KJ KF KA KN DC Voltages [V] Standard ZQ ZJ ZD ZS ZA ZT with Integrated Diode DJ Coil Voltage Code for spring clamp type terminal versions The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: V, Hz: Cat. No. -K becomes Cat. No.-KD. AC Voltages [V] Hz D Hz D / Hz KJ KF DC Voltages [V] Standard ZJ ZD with Integrated Diode DJ Publication A-CAA-EN-P -

3 Bulletin -K/-K IEC Miniature Contactors Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Bulletin -K Contactors and Accessories, Bulletin -K Overload Relays. (-/). (-/) (-/) (/) (-/). (-/) (-/). (-/). (-/) (-/) (-/). (-/). (-/) Mounting Position With Accessories * ) -Minimum distance to grounded parts or walls * ) Publication A-CAA-EN-P -

4 Bulletin -K, -K IEC Miniature Contactors Assignment of Contacts Assignment of Contacts Device Combinations in Accordance with IEC - / -- Table valid for : AC / DC =.. x U s, T amb. = - C + C, normal position (horizontal rail mounting) Auxiliary Contact Blocks Circuit Diagram -KFAE -KFC -KFAE -KFB -KFC -KFAE -KFC -KFAE -KFC -KFAE -KFC -KFAZ -KFB -KFC -KFAZ -KFC -KFAE -KFC Control K -K -K -K A A Miniature Contactors -K (AC and DC Control) K -K -K -K A A Front Mounting -K -K -K K A A K -K -K -K A A R R K -K -K -K A AC/DC + = AC/DC + = + = + = AC/DC + = AC/DC + = + = + = + = AC/DC + = + = + = + = AC/DC + = AC/DC + = + = + = + = AC/DC AC/DC + = + = AC/DC + = AC/DC + = + = + = AC/DC + = AC/DC + = + = + = AC/DC + = + = + = AC/DC AC/DC + = + = AC/DC + = AC/DC + = + = + = + = A R R R R For other operating limits, please contact our technical consultant. Combination possible but not recommended, due to repeating or not consecutive sequence numbering T amb. max. + C T amb. max. + C and only allowed for coil voltage V DC or V AC - Publication A-CAA-EN-P

5 Bulletin /-K, /-C, /-D, S/S-C, S-D -KR /-K /-C, S/S-C * * Coil Type : Conventional X X X X X X X X X X X X X X X Electronic EI AC- Active Power Load ( Hz); Ambient temperature C V [A] () V [A] () V [A] V [kw] I e V [kw]... V [kw].. V [kw] V [kw].. V [kw] V [kw] Ambient temperature C V [A] V [A] V [A] V [kw]... I e V [kw]... V [kw].. V [kw] V [kw].. V [kw] V [kw] Switching of -phase Motors; ( Hz) Ambient temperature C, AC-, AC- V [A] V [A] V [A]..... V [A]..... V [A]..... V [A]..... V [A] V [kw] V [kw] V [kw] V [kw]..... V [kw] V [kw] V [kw] Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) [A] Rated power (enclosed) V [A] phase V [A]. V [Hp] / /..... V [Hp] /... V [A] V [A] V [A] phase V [A].... V [Hp]... V [Hp]... V [Hp].. V [Hp].. - Publication A-CAA-EN-P

6 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X AC- Active Power Load ( Hz); Ambient temperature C Ambient temperature C Switching of -phase Motors; ( Hz) Ambient temperature C, AC-, AC- () () () () () () () () () () () () () () () (). Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) Rated power (enclosed) V: values in ( ) AC- and AC- lifespan - % Publication A-CAA-EN-P -

7 Bulletin /-K, /-C, /-D, S/S-C, S-D /-K /-C, S/S-C Conventional X X X X X X X X X X X Coil Type : Electronic EI Switching of -phase Motors, (Hz); Ambient temperature C, AC- V [A].... V [A].... V [A]... V [A]... V [A]... V [A]... V [A] V [kw].... V [kw].... V [kw]..... V [kw].... V [kw].... V [kw]..... V [kw] AC- at approximately, operations V [A] V [A] /V [A] V [A] V [A].... V [A] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw]... V [kw] Max. switching frequency Ops/h Wye-Delta ( Hz) V [Hp]. ½ ½ V [Hp]. ½ V [Hp]. V [Hp]. UL/CSA Elevator Duty V [A] V [A] V [A] V [A] V [Hp] ½ ½ V [Hp] ½ V [Hp] ½ V [Hp] ½ Star-Delta Starting ( Hz) V [A]. V [A]. V [A]... V [A]... V [A]... V [A].... V [A] V [kw].... V [kw]..... V [kw].. V [kw].. V [kw]... V [kw].... V [kw] Power ratings at Hz: Preferred values according to IEC - Approval pending on Cat. No. -D D. - Publication A-CAA-EN-P

8 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D X X X X X X X X X X X X X X X Switching of -phase Motors, ( Hz); Ambient temperature C, AC- () () () () () () () () () () () () () () () () AC- at approximately, operations.... Wye-Delta ( Hz) UL/CSA Elevator Duty.. TBD.. TBD.. TBD.. TBD TBD TBD TBD TBD Star-Delta Starting ( Hz) () () () () () () () () () () () () V: Values in ( ) AC- and AC- lifespan -% Approval pending on Cat. No. -D D. Publication A-CAA-EN-P -

9 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type : /-K /-C, S/S-C Conventional X X X X X X X X X X X Electronic EI Switching of Power Transformers, AC-a ( Hz) Inrush Current Rated transformer current = n V [A] V [A] V [A] V [A] V [A] V [A]..... n = V [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] n = V [A] n = V [A] Hz Peak Inrush/peak rated transformer current n = [A]..... V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Hz Peak Inrush/peak rated transformer current n = [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Hz Peak Inrush/peak rated transformer current n= [A] V [kva] V [kva] V [kva] V [kva] V [kva] V [kva] Publication A-CAA-EN-P

10 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D X X X X X X X X X X X X X X X Switching of Power Transformers, AC-a ( Hz) Hz Peak Inrush/peak rated transformer current Hz Peak Inrush/peak rated transformer current Hz Peak Inrush/peak rated transformer current Publication A-CAA-EN-P -

11 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type : Switching of -phase Capacitors, AC-b ( Hz) /-K /-C, S/S-C * * Conventional X X X X X X X X X X X X X Electronic EI V [kvar]. V [kvar]. V [kvar]. Single capacitor C V [kvar]. V [kvar]. V [kvar]. V [kvar] V [kvar]... V [kvar]... V [kvar].. C V [kvar]. V [kvar]. V [kvar]. V [kvar] V [kvar]. V [kvar]. V [kvar] Group capacitors C V [kvar] V [kvar] V [kvar] V [kvar] V [kvar].. V [kvar].. V [kvar] C V [kvar] V [kvar] V [kvar] V [kvar] Hz Single Capacitor C V [kvar]. V [kvar]. V [kvar] V [kvar] Hz Group Capacitors C V [kvar].. V [kvar].. V [kvar] V [kvar] Switching of Lamps Gas discharge lamps AC-a, C open [A].. enclosed [A].... Individually compensated: Max. capacitance at expected Short-circuit current of ka [μf] ka [μf] ka [μf] Filament AC-b /V [A] Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC ( Hz) V [A] AC-a V [A] V [A] Switching of Motor Load for Home Appliances ( Hz) AC-b V [A]. V [A] V [A].. Inductance of leads between capacitors in parallel: min. μh (-C C contactors: min μh) - Publication A-CAA-EN-P

12 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X Switching of -phase Capacitors, AC-b ( Hz) Hz Single Capacitor C Hz Group Capacitor C Switching of Lamps Individually compensated: Max. capacitance at expected Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC ( Hz) Switching of Motor Load for Home Appliances ( Hz) Publication A-CAA-EN-P -

13 Bulletin /-K, /-C, /-D, S/S-C, S-D /-K /-C, S/S-C * * Conventional X X X X X X X X X X X X X Coil Type : Electronic EI Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release ( Hz) V [A] AC-a V [A] V [A] - automatic reset of overload release V [A].. AC-b V [A].. V [A].. Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-, C V [A] /V [A] / /. /. pole V [A]. V [A] V [A] V [A] /V [A] poles in series V [A] V [A]... V [A].... V [A] /V [A] poles in series V [A] V [A] V [A] Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-, C V [A] /V [A] poles in series V [A] V [A]... V [A] Series-wound Motors Starting, reverse current braking, reversing, stepping DC-, C V [A] /V [A] poles in series V [A]. V [A]... V [A] Short Time Withstand I CW, C s [A] Resistance and Power Dissipation Main current circuit resistance [mω] Power dissipation by all circuits at I e AC-/V [W] Total power dissipation At I e AC-/V AC [W] DC [W] Lifespan Mechanical AC control [Mil. operations] Mechanical DC control [Mil. operations] Electrical AC- ( V) [Mil. operations] Weight AC DC Non- Rev. Rev. Non- Rev. Rev. kg (lbs.) kg (lbs.) kg (lbs.) kg (lbs.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) - Publication A-CAA-EN-P

14 Bulletin /-K, /-C, /-D, S/S-C, S-D /-C, S/S-C /-D, S-D * * X X X X X X X X X X X X X X X X X Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release ( Hz) - automatic reset of overload release Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-, C Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-, C Series-wound Motors Starting, reverse current braking, reversing, stepping DC-, C Short Time Withstand I CW, C Resistance and Power Dissipation Total power dissipation.... (.) (.) Lifespan Weight. (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) Values in brackets refer to electronic coil (EI) version.. (.) [. (.)]. (.). (.). (.). (.). (.). (.). (.). (.). (). (). (.) [. (.)]. (.). (.). (.). (.). (.). (.). (.). (.). (). () Publication A-CAA-EN-P -

15 Bulletin /-K, /-C, /-D, S/S-C, S-D -KR /-K /-C, S/S-C Coil Type : Conventional X X X X X X X X X X X X X X X X X Conductor Cross Sections - Main Contacts Terminal type Electr. EI () conductor [mm] () conductors [mm] () conductor [mm] () conductors [mm] b max. [mm] c max. [mm] s max. [mm] Ø min. [mm] Recommended torque [N m] Cross section per UL/CSA [AWG] Recommended torque [lb-in]... With terminal lug kit Cross section per UL/CSA [AWG] Recommended torque [lb-in] With Frame Terminal Block top opening [mm] bottom opening [mm] top opening [mm] bott. opening [mm] b max. s top s bottom [mm] Recommended torque [N m] Cross section per UL/CSA top [AWG] bottom [AWG] Recommended torque [lb-in] Pozidriv No. / Blade No. screw Pozidriv No. / Blade No. screw Hexagonal socket screw Fine- or coarse-stranded only - Publication A-CAA-EN-P

16 Bulletin /-K, /-C, /-D, S/S-C, S-D /-D, S-D X X X X X X X X X X X X. x x.. -DL -DL -DL -DL MCM (x) MCM (X) / MCM (X) / MCM -DTB -DTB / AWG AWG MCM AWG MCM AWG MCM Pozidriv No. / Blade No. screw Pozidriv No. / Blade No. screw Hexagonal socket screw Hexagonal screw Publication A-CAA-EN-P -

17 Bulletin /-K, /-C, /-D, S/S-C, S-D Short-Circuit Coordination Data Coil Type : /-K /-C, S/S-C * * * * Conventional X X X X X X X X X X X X X X X X X X Electronic El Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC -- (contactor and fuses only) DIN Fuses - gg, gl ka Available Fault Current Type "" (V) [A] Type "" (V) [A] Type "" (V) [A] BS Fuses ka Available Fault Current Type "" (V) [A] TBD Type "" (V) [A] TBD Per UL and CSA. No. (contactor and fuses or circuit breaker only) UL Class K and RK Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class K and RK Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class L Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class CC and CSA HRCI-MISC Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class J and CSA HRCI-J Fuses ka Available Fault Current UL Listed Combination (V) [A] UL Class CC and CSA HRCI-MISC Fuses ka Available Fault Current UL verified combination to IEC -- "Type " [A] UL Class J and CSA HRCI-J Fuses ka Available Fault Current UL verified combination to IEC -- "Type " [A] TBD UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] TBD UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] UL Inverse-Time Circuit Breaker ka Available Fault Current UL Listed Combination (V) [A] TBD A max. fuse for Type coordination. See for complete short-circuit current ratings. - Publication A-CAA-EN-P

18 Bulletin /-K, /-C, /-D, S/S-C, S-D /-D, S-D / X X X X X X X X X X X ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current / ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current ka Available Fault Current To be determined. Publication A-CAA-EN-P -

19 Bulletin /-K, /-C, /-D, S/S-C, S-D Coil Type - /-K Publication A-CAA-EN-P /-C, S/S-C * * * * Conventional X X X X X X X X X X X X X X X X X X Electronic EI Operating Limits Hz, Hz, pick-up [x Us] / Hz dropout [x Us] DC (conventional) DC (electronic) pick-up [x Us] dropout [x Us] pick-up [x Us].. dropout [x Us]. Coil Consumption Hz, Hz, pick-up [VA/W] / / / / / / / / / Hz hold-in [VA/W] /. /. / / /. /. /. / DC (conventional) DC (electronic) pick-up [W] cold., warm hold-in [W] cold., warm pick-up (avg/peak) [W] / / / hold-in [W]... Operating Times closing delay [ms] AC opening delay [ms] With RC module opening delay [ms] DC closing delay [ms] (conventional) opening delay [ms] With integ. diode With external diode opening delay [ms] V V opening delay [ms] DC (electronic) closing delay [ms] opening delay [ms] Max. Ripple ± % Min. OFF time [ms] For,,, and V DC coils /-D, S-D / / Conventional X X Coil Type Electronic EI X X X X X X X X X Operating Limits Hz, Hz, pick-up [x Us] / Hz dropout [x Us] DC control pick-up [x Us] dropout [x Us] Coil Consumption Hz, Hz, pick-up [VA/W] / / / / / Hz hold-in [VA/W] / / / / DC control pick-up [W] hold-in [W] Operating Times AC closing delay [ms] opening delay [ms] With RC module opening delay [ms] DC closing delay [ms] opening delay [ms] Integrated diode opening delay [ms] External diode opening delay [ms] Electronic coil drives are designed to minimize power requirements, but this control may exhibit a higher inrush ( W, < ms) when energizing. This must be taken into account for the proper sizing of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your local Rockwell Automation sales office or Allen-Bradley distributor for detailed information.

20 Bulletin /-K, /-C, /-D, S/S-C, S-D Auxiliary Contacts, Auxiliary Contact Blocks, and Pneumatic Timers Switching of AC Loads Internal -K -C, S-C -D, S-D Internal Frontmounted Frontmounted Frontmounted (Bifurcated) Sidemounted Convent'l Side-mounted Bifurcated Electronically compatible at C [A]. AC- I th at C [A] at V AC- at rated voltage of V [A]. /V [A]. V [A]. V [A]... ( ma) V [A] at V [A].. V V [A]... V [A] V [A].... Switching of DC Loads DC- L/R< ms resistive loads at V DC [A] V DC [A].. V DC [A] V DC [A] V DC [A] DC- L/R< ms inductive loads with economy resistor in series at V DC [A] V DC [A]... V DC [A]... V DC [A] V DC [A] DC- switching electromagnets at V DC [A]... V DC [A]... ( ma) V DC [A] at V DC [A] V V DC [A] Fuse gg Short-circuit protection with no welding of contacts per IEC -- [A] [A] Protective Separation per IEC -, Annex N Min. switching capacity according to IEC -- V/ ma V/ ma between load and auxiliary circuit V between load and auxiliary circuit V between load and auxiliary circuit V V/ ma V/ ma V/ ma V/ ma V/ ma Failure rate V/ ma ( Mio. ops.) <- (less than failure to Mio. operations) V/ ma Load Carrying Capacity per UL/CSA Rated voltage AC [V] max. max. max. max. General Continuous rating C [A]. purpose Heavy pilot duty Switching capacity AC [A] A B A. (A ) Rated voltage DC [V] max. max. max. max. Switching capacity DC [A] Q P Q Q Standard pilot duty (P ) Standard pilot duty (Q ). Publication A-CAA-EN-P -

21 Bulletin /-K, /-C, /-D, S/S-C, S-D General -K -C, S-C -D, S-D Rated Isolation Voltage U i IEC [V] UL, CSA [V] Rated Impulse Voltage Withstand U imp [kv] Rated Voltage U e AC / Hz [V],,,,,,,,,,,,,,,,,,,,,, DC [V],,,,,,,,,,,, Insulation Class of the Coil Class F per IEC Class insulation system per UL Class F per IEC Class B per VDE, Table Rated coil frequency AC / Hz, DC AC / Hz, DC AC Hz, / Hz, DC Ambient Temperature Storage [ C] Operation at rated voltage [ C] at C % current reduction against C values Climatic Withstand IEC -- IEC -- / - / - IEC -- Max. Altitude of Installation Site [m] NN, per IEC - NN, per IEC - NN, per IEC - Protection Class IPX IPX IP IEC / DIN Single contactor cover IP IEC / DIN Contactor with frame terminal block IP IEC / DIN Auxiliary contact IPX IP IEC / DIN Protection against Accidental Contact Finger and back-of-hand proof per VDE, part Finger and back-of-hand proof per VDE, part Resistance to Shock IEC - IEC -- IEC -- Resistance to Vibration IEC - IEC -- IEC -- Mechanically Linked Contacts IEC --, Annex L Mirror Contacts IEC - Annex F Standards Compliance Certifications -K (on main device) -K + -KF IEC/EN -/--/--; UL ; CSA.. No. CE, culus CCC - / S-C C + -FA/- FB/-FC, (except L, L), - / S-C C + -FAB/-FBB/- FCB - / S-C C + -FA/- FB/-FC, (except L, L), - / S-C C + -SA/SB, - / S-C C + -FAB/-FBB/- FCB IEC/EN -/--/--; UL ; CSA.. No. CE, culus, CCC -D + x -DS- S-D + x S-DS- IEC/EN -/--/--; UL ; CSA.. No. CE, culus, CCC - Publication A-CAA-EN-P

22 Bulletin -K/-K IEC Miniature Contactors Bulletin -K/-K Life-Load Curves Electrical life; U e = V AC AC- Switching of squirrel-cage motors while starting AC- Non- or slightly inductive loads, resistance furnaces Contact Life (millions of operations). -K -K -K. Electrical life; U e = V AC AC- Stepping of squirrel-cage motors -K; -K Rated current Ie AC- [A] (Dashed curves AC- only, open) -K Contact Life (millions of operations)... Rated current Ie AC- [A] Publication A-CAA-EN-P -

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / / Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts

More information

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / / Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor

More information

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................

More information

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K Bulletin Overview/Product Selection Προδυχτ Σελεχτιον Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUA Red Cover and

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

PKZ 2 Manual Motor Protectors Technical Data

PKZ 2 Manual Motor Protectors Technical Data 08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Description Basic devices with positive operation contacts

Description Basic devices with positive operation contacts Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000

More information

Type: DILM40(RDC24) Article No.:

Type: DILM40(RDC24) Article No.: Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation

More information

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Solid-state Contactor Specifications

Solid-state Contactor Specifications Technical Data Solid-state Contactor Specifications Bulletin Number 156 Topic Page Topic Page Catalog Number Explanation 2 Dual- and Three-phase Devices 25 Single-phase Devices 3 Product Selection 25 Product

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Supplemental Motor Protection Devices Table of Contents

Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6 Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram

More information

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Bulletin 700-R -RM Sealed Switch Relays

Bulletin 700-R -RM Sealed Switch Relays Bulletin 700-R -RM Sealed Switch Relays Bulletin 700 R, RM Sealed Switch Relays Sealed contacts Extremely long mechanical and electrical life Hazardous locations Class 1, Div Groups A, B, C, D Harsh environments

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions

More information

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10 Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -

More information

RJ Series Slim Power Relays

RJ Series Slim Power Relays RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC Overview/Product Selection Bulletin 700-FS Adjustable Function and Timing Range DIN Rail Mounted without Cost of Socket 22.5 mm Wide Multifunction or Single Functions Available as SPDT or DPDT Contact,

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Bulletin 700-RTC Solid-State Timing Relay

Bulletin 700-RTC Solid-State Timing Relay Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Small but rugged DRAFT

Small but rugged DRAFT Series C8 and CT8 Starters n ingenious miniature contactor and starter system Sprecher + Schuh s New C8 Series of miniature contactors and starters provide an extremely compact and reliable method of controlling

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Pluggable interface relays CR-U Universal relays

Pluggable interface relays CR-U Universal relays Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU /0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information