Open Type Without Enclosure
|
|
- Aron Jennings
- 5 years ago
- Views:
Transcription
1 Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General Use Resistive Heating Ballast Lighting (Fluorescent) Discharge Lighting (Mercury Vapor High Pressure Sodium and Metal Halide) Open Type Without Enclosure Type General Purpose Enclosure Type /X Watertight, Corrosion- Resistant Enclosure Stainless Steel Power Poles V AC Maximum Hz Type R// Rainproof, Dusttight Industrial Use Enclosure Cat. No. Cat. No. Cat. No. Cat. No. L-TO L-TA L-AO L-AA L-AC L-AJ L-BO L-BA L-BC L-BJ L-CO L-CA L-CC L-CJ L-DO L-DA L-DC L-DJ L-EO L-EA L-EC L-EJ L-FO L-FA L-FC L-FJ L-GO L-GA L-GC L-GJ L-HO L-HA L-HC L-HJ L-JO L-JA L-KO L-KA General Use Resistive Heating Tungsten Lamp Loads (Max. V Line, V Load) Ballast Lighting (Fluorescent) Discharge Lighting (Mercury Vapor High Pressure Sodium and Metal Halide) Cat. No. Cat. No. Cat. No. Cat. No. Power Poles V AC Maximum Hz L-TO L-TA L-AO L-AA L-AC L-AJ L-BO L-BA L-BC L-BJ L-CO L-CA L-CC L-CJ L-DO L-DA L-DC L-DJ L-EO L-EA L-EC L-EJ L-FO L-FA L-FC L-FJ Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. L-AO becomes Cat. No. L-AOD. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. [V] AC, Hz K S P T N KN I Q M R AC, Hz J D H A F U B C Fiberglass-reinforced polyester hubs are included with each starter. Does not include line and load lugs, see page - for kits. Feed-through wiring only. Only available on sizes. When using V coils on size or, an interposing relay may be required. See coil VA values on page -. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. Special Purpose Bolted Enclosures Hazardous Location Contactor Type & ; Class I, Groups C & D; Class II, Groups E, F & G Type R, & ; Class I, Groups C & D; Class II, Groups E, F & G Size Poles Divisions & Enclosure Code (E) Divisions & Enclosure Code (H) Available Available - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P
2 Bulletin Line Approximate Dimensions NEMA AC Contactors Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin FL, L, and LP and for NEMA sizes, for Bulletin and F Contactors Note: Top mounting hole on Size is / in. (. mm) to the left of centerline on Open Type. Mounting screws: # for sizes, / #, or / # for sizes. NEMA Size /A /A A A A A A Bulletin F-FL Number of Switching Poles Bulletin L-LP -- A Width -/ () -/ (.) -/ () -/ () -/ () -/ () -/ () -/ (.) -/ (.) -/ (.) () -/ (.) -/ (.) () For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. ( mm). B Height -/ () () -/ () -/ () -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -/ (.) -/ () -/ () -/ (.) -/ (.) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () Approximate Shipping Weight [lb (kg)] (.) (.) -/ (.) -/ (.) (.) -/ (.) -/ (.). (.) (.) () (). (.). () (.) - Publication A-CAA-EN-P
3 Bulletin Line Mechanical Ratings NEMA Size Mechanical Life (Millions of Operations) Maximum Number of Auxiliary Contacts Operating Time [ms] Pick-up (Average) Drop-out (Average) Construction NEMA Size Wire Size for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs Type of Power Terminal # AWG lb in Pressure terminals # AWG lb in # AWG lb in Saddle or wire clamps # AWG lb in Pressure terminals # / AWG lb in # / AWG lb in # AWG MCM lb in Lugs sold separately. See page -. Direct bus connections only. Environmental Power Contacts Silver alloy Contact Material Auxiliary Contacts Silver Requirements for Sizing of Wire All wire rated F ( C) or higher must be sized per the local Electrical Code for F ( C) wire. NEMA Size Operating Position Operating Temperature Range Altitude Corrosion-Resistance Horizontal Starters with eutectic alloy Overload relay + F ( + C) Vertical Horizontal Vertical Starters with SMP Overload relay + F ( + C) (provided condensation is prevented) feet before derating All metal parts are treated for corrosion-resistance Publication A-CAA-EN-P -
4 Bulletin Line Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletin,,, E, F, G, and X NEMA Size Combination Contactors and Starters with Disconnect Switch: Bulletin,,, E, F, G, and X Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] H, K Maximum Voltage [V] H, K J, R L L Combination Lighting Contactors with Disconnect Switch: Bulletin L Available Short Circuit Amperes RMS Lighting Contactor Rating [A] Fuse Type Symmetrical [A] Maximum Voltage [V] H, K H, K J, R Combination Contactors and Starters with Circuit Breaker: Bulletin,,, E, F, G, and X Available Short Circuit Amperes RMS Enclosure Type NEMA Size Symmetrical [A] Maximum Voltage [V], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & R, R// Combination Lighting Contactors with Circuit Breaker: Bulletin L Available Short Circuit Amperes RMS Enclosure Type Lighting Contactor Rating [A] Symmetrical [A] Maximum Voltage [V], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & For the most up-to-date SCCRs, please see the on-line Industrial Controls catalog at - Publication A-CAA-EN-P
5 Bulletin Line AC Coil Data NEMA Size Operating Volt Amperes Burden [VA] Inrush Hz Coils Sealed Heat Dissipation [W].. & P. ( poles). ( poles). ( poles) ( poles) ( poles). ( poles). (Series L).. (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay). Coil Operating Limits % This rating is for the size contactor coil only. All starters are shipped with an interposing relay as standard. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Auxiliary Contacts (NEMA A and P) Bulletin, AC Rating Designation A Maximum AC Contact Rating Per Pole [A] Continuous [VA] Maximum Voltage Carrying Current or Hz Make Break [A] Make Break.. Maximum DC Contact Rating Per Pole for, Auxiliary Contacts (Maximum Continuous Carrying Current is A) DC Rating Designation V DC V DC V DC P. A. A (Requires Contacts in Series). A (Requires Contacts in Series) Publication A-CAA-EN-P -
6 Bulletin Line Load-Life Curves Bulletin Line contactors and starters are designed to provide superior performance in a variety of applications. These load-life curves are based on Rockwell Automation tests according to the requirements defined in IEC -. Actual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves. To find the contactor s estimated electrical life, follow these guidelines: Choose the appropriate graph that most closely approximates the utilization category of the application. Locate the intersection of the life-load curve of the appropriate contactor with the application s operational current (I e ) found on the horizontal axis. Read the estimated contact life in millions of operations along the vertical axis. Contact Life for Mixed Utilization Categories AC and AC In many applications, the utilization category cannot be defined as either purely AC or AC. In those applications, the electrical life of the contactor can be estimated from the following equation: L = mixed L AC L AC AC + P ( ) L AC Where: L mixed = Approximate contact life for a mixed AC/AC utilization category application L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) P AC = Percentage of AC operations Utilization Categories CategoryTypical Duty ACStarting of squirrel cage motors and switching off only after the motor is up to speed. ACStarting of squirrel cage motors with inching and plugging duty. Bulletin Load/ Life Curves AC and AC M M M M M NEMA SIZE AC NEMA SIZE M M M M M AC M OPERATING CYCLES M K K K K OPERATING CYCLES K K K K K K K K K K K K K K K K OPERATIONAL CURRENT le (APMERES) OPERATIONAL CURRENT le (APMERES) - Publication A-CAA-EN-P
7 Bulletin Line Group Motor Ratings for NEMA Contactors/Starters Manual Starters FLA Range (Amps) Group Rating (V) Contactors w/o Limiter with Limiter Size Size Size Size Size -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -BO -CO -MN+- P -MN+- P.. ka -CO -DO.. ka -CO -DO Group Rating (V) Starters FLA Range Manual Starters (Amps) w/o Limiter with Limiter Size Size Size Size Size -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -BO -CO -MN+- P.. ka -CO -DO -MN+- P.. ka -CO -DO Cat. No. is incomplete. Refer to page -. Cat. No. is incomplete. Refer to page -. Publication A-CAA-EN-P -
8 Bulletin Line Full Load Currents of -Phase, Hertz AC Induction Motors The full load currents listed below are average values for horsepower rated motors of several manufacturers at the more common rated voltages and speeds. These average values, along with the similar values listed in the U. S. National Electrical Code (NEC), should be used only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the motor nameplate, may vary considerably from the listed value depending on the specific motor design. ATTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running Overcurrent Protection. HP / / / / -/ -/ RPM Full Load Current [A] V V V V V V Synchronous speed nameplate is usually less due to slip HP RPM Full Load Current [A] V V V V V V Publication A-CAA-EN-P
Open Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationNEMA Contactor and Starter Specifications
Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationDeploying Current Transformers in Applications Greater Than 200 A
Deploying Current Transformers in Applications Greater Than 200 A Andrew Schaeffler Step-down Current Transformers (CTs) are common, and useful, in large motor applications. They provide isolation between
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationAC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10
Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts
More informationPowerFlex 400 Submittal
PowerFlex 400 Submittal Submittal Date: Project Name: Project Location: Consulting Engineer: Contractor: Contractor PO #: Distributor Name: Distributor Contact: Distributor Reference #: Note: This is general
More informationFor additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:
Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of
More informationand START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.
6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO
More informationBulletin 700-RTC Solid-State Timing Relay
Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,
More informationSupplemental Motor Protection Devices Table of Contents
Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor
More informationStarting Torque Controller Technical Data
Technical Data Starting Torque Controller Technical Data Bulletin 154 Topic Page Product Overview 2 Catalog Number Explanation 2 Product Selection 3 Specifications 3 Wiring Diagrams 9 Approximate Dimensions
More informationBulletin 140U Molded Case Circuit Breakers
Bulletin 40U Multitap End Cap Optional Optional Optional 40U-J-MTLA 40U-J-MTL6A 40U-J-ECM Aluminum Aluminum Molded Housing /4 screw /4 screw lb-in lb-in.6 N m.6 N m Cu/Al Cu/Al 60/7 C 60/7 C () (6) (A)
More informationDescription & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...
SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make
More informationNEMA Size 1 Cat. No. CN55DN3AB
-80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79
More informationBulletin 700-R -RM Sealed Switch Relays
Bulletin 700-R -RM Sealed Switch Relays Bulletin 700 R, RM Sealed Switch Relays Sealed contacts Extremely long mechanical and electrical life Hazardous locations Class 1, Div Groups A, B, C, D Harsh environments
More informationKinetix 300 Drive (single-phase and three-phase) Power Specifications
Chapter 4 Kinetix 3 EtherNet/IP Indexing Servo Drives Kinetix 3 Drive (single-phase and three-phase) Power Specifications Attribute 297-V33PR1 297-V33PR3 297-V33PR5 297-V33PR6 AC input voltage AC input
More informationBulletin 1497 Global Control Transformers
Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Circuit Transformers Bulletin 1497 Global Control Circuit Transformers are designed to reduce supply voltages to control circuits.
More information1394 External Shunt Resistor Kit
Installation Instructions 1394 External Shunt Resistor Kit (Catalog Number 1394-SR10A) Introduction This publication provides the information necessary to install the 1394 External Shunt Resistor kit on
More informationAC Magnetic Starters (GE)
AC Magnetic Starters (GE) Description of Operation With Local or Remote Start-Stop Selector Switch (LVR) Control Starting Stopping Restarting Turning the selector switch to START energizes M and starts
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationBulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide
Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationSolid-state Contactor Specifications
Technical Data Solid-state Contactor Specifications Bulletin Number 156 Topic Page Topic Page Catalog Number Explanation 2 Dual- and Three-phase Devices 25 Single-phase Devices 3 Product Selection 25 Product
More information1204 Reflected Wave Reduction Device
Instructions 1204 Reflected Wave Reduction Device (Catalog Number 1204-RWR2-09-B, C) This publication will guide you through installation (including mounting, wiring and grounding procedures) of the 1204
More informationBUCK-BOOST TRANSFORMERS
Where Are Buck-Boost Transformers Used? A typical buck-boost application is 120 volts in, 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage transformer
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationIC800SSD Hardware Manual Pub 348R5. for models. A publication of
IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A
More informationSupplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationBulletin 520 Multi-Speed
Bulletin 520 Multi-Speed Bulletin 520 NEM sizes 0 7 Exceptional electrical life Dependable coil operation Eutectic alloy overload relays: Class 10, 20, or 30 Solid-state overload relays: Class 10, 15,
More informationSingle, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N
Bulletin Product Overview/Catalog Number Explanation Cat. No. -B-HXJX--N Control Circuit Transformer, - pole with Optional Cat. No. -R Fuse Cover Cat. No. -C-BASX--N Control Circuit Transformer, Non-Fused
More informationReduced Voltage Starters
Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current
More informationReduced Voltage Starters
Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current
More informationMini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU
/0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing
More informationVariable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation
Variable Frequency Drive Packages with Harmonic Mitigation Low Harmonic Drive Packages Engineered by Rockwell Automation What Do I Need to know About Harmonics? What are Harmonics? Harmonics are deviations
More informationAF91 Adjustable Frequency Drives Series B
Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based
More informationSupplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation
More informationSIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV
Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationInstruction Bulletin Reduced Voltage Starters Autotransformer Type Class 8606
Instruction Bulletin educed Voltage Starters Autotransformer Type Class 8606 Bulletin No. 50006-025-01E December,1994 aleigh, NC, U.S.A. Supersedes 50006-025-01D dated 11/92 eference No. 8606-1 educed
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationKinetix 6000 Integrated Axis Modules
Chapter 6 Kinetix 6000 Multi-axis Servo Drives Kinetix 6000 Integrated Axis Modules This section contains power specifications, mounting dimensions, and catalog numbers for the Bulletin 2094 (230V and
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationHigh Frequency Sinewave Guardian TM Filter
High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationACS600, ACS800. Installation Guide
ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368
More informationATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW
Characteristics soft starter for asynchronous motor - ATS01-22 A - 200..240 V - 4..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationSELECTION GUIDE. BULLETIN 156 Solid-State Contactors
SELECTION GUIDE BULLETIN 156 Product Overview/Product Selection Bulletin 156 The Bulletin 156 are ideal replacements for electro-mechanical contactors where fast and demanding switching of loads such
More informationInverter MICROMASTER 410
Inverter MICROMASTER 40 /2 Description /4 Circuit diagrams /6 Technical data /7 Selection and ordering data /8 Options /0 Dimension drawings Siemens DA 5.2 2005/2006 / MICROMASTER 40 Description Inverter
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationConnection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K
Bulletin Overview/Product Selection Προδυχτ Σελεχτιον Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUA Red Cover and
More informationPF/PFQ. High Amperage plug and receptacle. Main Advantages
High Amperage plug and receptacle Main Advantages u u u Durable in harsh environments Safety features provide maximum protection Easy plug insertion and removal Watch the PF video and other product videos
More informationKRPA, KRP, KA, KR series
Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting
More informationPowerGard Series C 18-Pulse Enclosed Drive Controllers
PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive and power quality solutions PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive
More informationDPC F - P3-24. Part Number Scheme. Dimensions
Description Definite Purpose Contactor Definite Purpose contactors are electrically operated switching devices specifically designed for the heating, ventilation, air conditioning, heat pump and refrigeration
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationType 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs
Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationHigh Frequency SineWave Guardian TM Filter
High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationBulletin 1497 Global Control Transformers
Bulletin 1497 Global Control Transformers Bulletin 1497 Multi Tap Transformers 1497 A M1 3 N VA Rating and Voltage Fuse Block Options Factory Installed Options Code Description Code Code Block Options
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW
Product datasheet Characteristics ATS01N206QN soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Complementary Assembly style Function available Supply voltage limits Main Range of
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact Footprint Superior
More informationCrane Control Class 7001
Catalog 17 CONTENTS Description.....................................................Page.................................................. 0 ST DC Static Timer............................................
More information+ 24V 3.3K - 1.5M. figure 01
ELECTRICITY ASSESSMENT 35 questions Revised: 08 Jul 2013 1. Which of the wire sizes listed below results in the least voltage drop in a circuit carrying 10 amps: a. 16 AWG b. 14 AWG c. 18 AWG d. 250 kcmil
More informationATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW
Characteristics soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP
Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO:
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More informationBLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany
2354235 11/2008 Soft start - soft stop unit SH31 User manual 09/2010 BLEMO Frequenzumrichter Siemensstraße 4 D-63110 Rodgau Dudenhofen Germany Tel.: ++49 / 6106 / 82 95-0 Fax: ++49 / 6106 / 82 95-20 Internet:
More informationAmpere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001
MAG-GARD Motor Circuit Protector Class, 8, 6, 68 Instantaneous trip magnetic onl circuit breakers have a single adjustment which simultaneousl sets the magnetic trip level of each individual pole. MAG-GARD
More informationAmbient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3
CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2
More informationMotor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87
Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationS&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)
Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be
More informationBulletin 505 Full Voltage Reversing
Bulletin 505 Full Voltage Reversing Bulletin 505 NEM sizes 00 8 Exceptional electrical life Dependable coil operation Eutectic alloy overload relays: Class 10, 20, or 30 Solid-state overload relays: Class
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationT e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker
T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion
More informationMiniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays
Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationIGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards
APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2
More informationSIRIUS/SIKOSTART Soft Starters For Standard Applications
Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase