1 UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide min. -/ in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (item ) to purlins to be No. 0-6 by in. long No. self-drilling point, No. Phillips drive head, cadmium plated steel screws. Two screws per clip to be used, inserted through / in. diameter guide holes. Purlins No. 6 MSG min. thickness steel (0,000 psi min. yield strength). Spacing: For MSG thickness panels - 60 in. OC For MSG thickness panels - 8 in. OC HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
2 UL Construction No. Wind-Uplift - Class 90 and 60 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG min. thickness coated steel. Panels 8 in. wide max., 0 in. wide min. -/ in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (item ) to purlins to be No. 0-6 by in. long cadmium plated pancake head No. phillips drive, No. self-drilling point steel screws. Two screws per clip to be used inserted through / in. diameter guide holes. Purlins No. 6 MSG min. thickness steel (0,000 psi min. yield strength). Spacing for Class 90 to be 8 in. OC: For Class 60 to be 60 in. OC HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
3 UL Construction No. 6 Wind-Uplift - Class 90 or 60 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad 0.0 in. thick aluminum or No. MSG min. thickness coated steel. Panels 0 in. wide. -/ in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (Item ) to purlins to be No. 0-6 by in. long cadmium plated, pancake head, No. phillips drive, No. self-drilling point. Two screws per clip to be used, inserted through / in. diameter guide holes in clip base. Purlins No. 6 MSG min. thickness steel (0,000 psi min. yield strength). Spacing for aluminum panels: Spacing for steel panels: For Class 90 to be 6 in. OC. For Class 60 to be 8 in. OC. MSG thick to be 60 in. OC. MSG thick to be 8 in. OC. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
4 UL Construction No. 0 Uplift - Class 90 / Fire Not Investigated Metal Roof Deck Panels * / Snap-Clad No. MSG min thickness coated steel. Panel width 8 in. max., 0 in. min., -/ in. high at the ribs. A bead of sealant may be used at panel side joints. A Metal Roof Deck Panels* (Not Shown) 0.0 in. min thick aluminum, 6 in. wide max, 0 in. wide min, -/ in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in.. high. Clip spacing to be 8 in. max. OC for steel panels and 8 in. max. OC for aluminum panels. Clips to interface with Item A (bearing plate). A Bearing Plate* (Not Shown) To be used with Snap-Clad Clips only (Item ). To be MSG thick coated steel, nom -/8 in. wide by 6 in. long. 6 7 Fasteners used to attach panel clips and bearing plates (Items & A) through rigid insulation and optional OSB and/or gypsum board and into light gauge steel deck (Item No. ) to be No. truss head type with No. Phillips drive, self-drilling steel screws. Two screws per clip to be used, inserted through / in. diameter guide holes. Fasteners to penetrate liner panel / in. min. Foamed Plastic (Rigid Insulation) Min thickness in., max thickness -/ in. Density to be a min of.8 pcf. A 7/6 B Oriented Strand Board (OSB) (Optional) (Not Shown) Located over foamed plastic (Item ). Max thickness in. Note: Bearing plates not required when OSB is used. Gypsum Board (Optional) Max thickness /8 in. Located over liner panel (Item ). Liner Panel Min thickness No. MSG. Coated steel (,000 psi) min yield strength min. depth -/ in., max. pitch 6 in., fabricated to various profiles. Underlayment (Not shown) One ply of 0 lb roofing felt or one layer of bituminous resin type water proofing membrane. Supports (Not Shown) Used to support liner panels, spaced per deck manufacturer s specifications for uplift. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
5 UL Construction No. Uplift - Class 90 / Fire Not Investigated Metal Roof Deck Panels* / Snap-Clad No. MSG min. coated steel panels 8 in. wide max., 0 in. wide min., -/ in. high at the ribs. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. Clips spaced 6 in. OC, max, fastened to plywood deck. Fasteners used to attach panel clips (Item ) to plywood to be No. 0- by in. long pancake head, No. Phillips drive, A-point, coated steel screw. Min two fasteners per clip to used. Underlayment Underlayment used over plywood deck to be Type or 0 organic felt. Sides overlapped min. in., end laps per manufacturer s instructions. Felt nailed to plywood deck with -/ in. long steel cap nails, located per manufacturer s instructions. Nail spacing to be max in. OC at the side lap and max in. OC in interior rows. As An Alternate: A self-adhering modified bitumen water proofing membrane may be used, installed per manufacturer s instructions. Note: when alternate is used the plywood joints need not be sealed. Plywood Decking Plywood decking to be graded per PS8 specifications, 9/ in. thick, exposure, APA Rated Sheathing (/0) square edged, Butt ends not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant applied with a caulking gun and feathered outward from the joint. (Note exception under Item No., alternate.) Supports (Not Shown) Spaced max of in. OC. Any of the following types may be used to support the plywood decking: a) Nom. by 6 in., No. grade or better S-P-F, Hemlock Fir, Douglas Fir or Southern Yellow Pine or equivalent. b) Wood trusses with a nom. by in. upper chord of the same grade as item a. c) No. MSG min cold formed coated steel (min. yield to be,000 psi). Plywood Fasteners (Not Shown) Fasteners used to attach the plywood deck or OSB to the supports to be as follows: a) For plywood-to-wood supports No. 8-8 by -7/8 in. long bugle-head steel screws with a No. Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 0 MSG No. 7-9 by -/ in. long bugle-head steel screws with a No. Phillips head drive Hi-Low threads and an S-Point. For a steel thickness greater than No. 0 MSG to No. 6 MSG, No. 6-0 by -/ in. long bugle-head steel screws with a No. Phillips drive and a S (TEKS/)supR point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and in. OC in the interior. Refer to General Information, Roof Deck Construction (Building Materials Directory) for items not evaluated. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
6 UL Construction No. 08 Uplift - Class 90 / Fire Not Investigated 6 MAX MAX Metal Roof Deck Panels* / Snap-Clad 0.0 in. min. thick aluminum; Panels 6 in. wide max., 0 in. wide min., -/ in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. Clips spaced 8 in. OC. Fasteners used to attach panel clips (Item ) to plywood (Item ) to be No. 0- by in. long, No. Phillips drive, bugle head coated steel wood screws. Two screws used per clip inserted through / in. diameter guide holes. Underlayment Underlayment used over plywood deck to be Type 0 organic felt. Sides overlapped min. in., end laps per manufacturer s instructions. Felt nailed to plywood deck with in. long galvanized steel roofing nails, located per manufacturer s instructions. Nail spacing to be max in. OC at the side lap and max in. OC in interior rows. As An Alternate: A self-adhering modified bitumen water proofing membrane may be used, installed per manufacturer s instructions. Note: when alternate is used the plywood joints need not be sealed. Supports Spaced max in. OC. Any of the following types may be used to support the plywood decking: a) by 6 in., min No. grade A.F.P.A. S-P-F Hemlock Fir, Douglas Fir or Southern Pine or equivalent. b) Wood trusses with a nominal by in. upper chord of the same grade as item a. c) No. MSG min thick cold formed coated steel (min. yield to be,000 psi). Plywood Fasteners (Not shown) Fasteners used to attach the plywood deck to the supports to be as follows: a) For plywood-to-wood supports No. 8-8 by -7/8 in. long bugle-head steel screws with a No. Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d by -/ in. long deformed shank common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 0 MSG, No. 7-9 by -/ in. long bugle-head steel screws with a No. Phillips head drive Hi-Low threads and an S-Point. For a steel thickness greater than No. 0 MSG to No. 6 MSG, No. 6-0 by -/ in. long bugle-head steel screws with a No. Phillips drive and a S (TEKS/) point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and in. OC in the interior. Plywood Decking Plywood decking to be graded per PS8 specifications, 9/ in. thick, exposure, APA rated sheathing (/0) square edged, Butt ends not blocked. Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
7 UL Construction No. 08A Uplift - Class 90 / Fire Not Investigated 8" MAX. (STEEL) 6" MAX. (ALUM.) NOM. Metal Roof Deck Panels* / Snap-Clad No. MSG min. thick coated steel panels, 8 in. wide max., 0 in. wide min., or 0.0 in. min. thick aluminum, 6 in. wide max., 0 in. wide min., / in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. Clips spaced 6 in. OC max for steel panels and 8 in. OC max for aluminum panels. Fastened to nailable insulation (Item ). Fasteners (Screws) Fasteners used to attach panel clip (Item ) to nailable insulation (Item ) to be No. 0- by in. long pancake head, No. Phillips drive, A-point coated steel screws. Min. two fasteners per clip. Underlayment Underlayment used over nailable insulation (Item ) to be Type 0 organic felt. Sides overlapped min. in. End laps per manufacturer s instructions. Felt nailed to nailable insulation with in. long galvanized steel roofing nails, located in side laps and between side lap per manufacturer s instructions. Nail spacing to be max in. OC at the side lap and max in. OC in interior rows. Nailable Insulation Consisting of in. min. to -/ in. max thick Classified polyisocyanurate foamed plastic with a factory laminated 7/6 in. thick APA rated O.S.B. Density of foamed plastic to be pcf. 7 8 Fasteners (Screws) Fasteners used to attach nailable insulation (Item ) to liner panel (Item 8) to be No. -, No. Phillips drive, truss head, painted steel screws. Length to depend on overall thickness of deck and to penetrate steel deck / in. min. A in. diameter formed pressure plate fabricated from No. MSG coated steel to be used with each screw. Fasteners located in three rows along the 8 ft. length of the nailable insulation beginning 6 in. from the 8 ft. edges with a row down the center and spaced in. OC beginning 6 in. from the ft. edges. A total of fasteners used for each by 8 ft. board. Liner Panel (Steel Deck) No. MSG min. thick coated steel. Min. depth -/ in., max pitch 6 in. fabricated to various profiles. Min. yield strength,000 psi. Fastened to supports (Item 6) with fastener type and spacing per liner panel manufacturer s instructions for uplift loading. Gypsum Board (Optional - Not Shown) 9 Max. thick /8 in. supplied in by 8 ft. sheets. Butt joints located over crests of metal roof deck panel (Item ). Fastened to panel with same fasteners used for nailable insulation (Item ). Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. 6 Supports (Purlins) Purlins used for liner panel (Item 8) support to be cold formed steel sections. As alternatives, structural steel components (hot rolled beams, channels, open web joists, etc.) may be used. Min. gauge and yield to depend on design considerations for uplift loading with max spacing to be 6 ft. OC. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
8 UL Construction No. 6 Uplift - Class 90 / Fire Not Investigated 6 MAX MAX Metal Roof Deck Panels* / Snap-Clad 6 in. wide max., 0 in. wide min., -/ in. high at the rib, fabricated from 6 oz., half-hard copper. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, -/ in. wide, -7/8 in. high. The clips are to be spaced a maximum of in. OC. Fasteners used to attach panel clips (Item ) to plywood (Item ) to be No. 0-6 by in. long, No. in. pancake head coated stainless steel screws. Two screws used per clip inserted through / in. diameter guide holes. Underlayment* Any UL Classified base or ply sheet, mechanically fastened with nails or Astaples. Underlayment: Rosin paper, 9 mil. thick, mechanically fastened with nails or staples. Plywood Decking Plywood decking to be graded per PS8 specification, 9/ in. thick, Grade B-C, exposure, APA rated sheathing (/0) square edged. All plywood joints to be sealed against leakage with caulk or a one part urethane sealant. c) No. MSG min. thick cold formed coated steel (min. yield to be,000 psi). Plywood Fasteners (Not shown) Fasteners used to attach the plywood deck (Item ) to the supports (Item 6) to be as follows: a) For plywood-to-wood supports, No. 8-8 by -7/8 in. long bugle-head steel screws with a No. Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d by -/ in. long deformed shank common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 0 MSG, No. 7-9 by -/ in. long bugle-head steel screws with a No. Phillips head drive Hi-Low thread and an S-Point. For a steel thickness greater than No. 0 MSG to No. 6 MSG, No. 6-0 by -/ in. long bugle-head steel screws with a No. Phillips drive and a S (TEKS/) point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and in. OC in the interior. Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. 6 Supports Spaced max in. OC. Any of the following types may be used to support the plywood decking: a) by 6 in., min. No. grade A.F.P.A. S-P-F Hemlock Fir, Douglas Fir or Southern Pine or equivalent. b) Wood trusses with a nominal by in. upper chord of the same grade as item a. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
9 UL Construction No. 790 Class A Coated Steel and aluminum panels identified as Snap-On Standing Seam, High Snap-On Standing Seam, Snap-On Batten, Integral Batten, Redi-Roof Batten, Redi-Roof Standing Seam, Snap-Clad, Integral Standing Seam, Tite-Loc and Tite-Loc Plus. Barrier Board: Ply Sheet (optional): NC / in. min. Georgia Pacific Corp. Dens-Deck Overlayment Board Any UL Classified Type G, G or G base/ply sheet, Type, 0 or 0 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels, mechanically fastened Barrier Board: Ply Sheet (optional): NC /8 in min. plywood Any UL Classified Type G, G or G base/ply sheet, Type, 0 or 0 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel roofing panels mechanically fastened Barrier Board: Ply Sheet (optional): NC 7/6 OSB or /8 in. plywood over polyisocyanurate insulation board or polyisocyanurate composite board, any thickness Any UL Classified Type G, G or G base/ply sheet, Type, 0 or 0 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened Barrier Board: Ply Sheet (optional): NC Polyisocyanurate, glass fiber, perlite or wood fiber, any thickness Any UL Classified Type G, G or G base/ply sheet, Type, 0 or 0 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened NC Steel roofing panels mechanically attached to metal purlins 6 Barrier Board: Ply Sheet (optional): C-/ Georgia Pacific Corp. / in. (min.) Dens-Deck with all joints staggered a min. of 6 in. from the plywood joints Any UL Classified Type G, G or G base/ply sheet, Type, 0 or 0 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
10 UL Construction No. 6 Metal Roof Deck Panels / File R9 Mechanically Attached Metal Roof Panels Mechanically Attached Metal Roof Panels Type Snap-Clad roof deck panels (No. MSG min gauge coated steel or 0.0 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Type Snap-Clad panels are secured by Snap-Clad Clips with the upper portion of the clip engaging the panel rib. A -/ by 6 in. bearing plate fabricated from No. 6 MSG coated steel is used under each panel clip (the bearing plate shall be placed over the specified insulation). Panel clips are attached to the steel deck with No. steel screws having a No. Phillips-drive truss head with an off-set drill-type point. Two fasteners per clip are used. For use in Design Numbers: P, P7, P0, P, P7, P9, P08, P0, P, P, P70, P7, P77, P70, P7, P7, P7, P76, P7, P7, P76, P80, P8, P89 and P8. Mechanically Attached Metal Roof Panels Types High Snap-On Standing Seam, Snap-On Standing Seam, Integral Batten, Integral Standing Seam, Redi-Roof Standing Seam, Redi-Roof Batten, Snap-Clad, Tite-Loc, Tite-Loc Plus roof deck panels (No. MSG min. gauge coated steel or 0.0 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Panels secured to a top layer of 7/6 in. APA-Rated oriented stand board (OSB) laminated to rigid insulation or /8 in. plywood over rigid insulation. Panels secured to oriented strand board or plywood at side ribs with panel clips designed specifically for these panels. Panel clips spaced 8 in. OC using No. 0 by -/ in. long self-drilling, self tapping wafer head. Zinc-plated carbon steel screws. The oriented strand board laminated insulation or plywood covered rigid insulation are mechanically fastened to steel roof deck and covered with a 0 lb. felt. For use in Design Numbers: P, P7, P0, P, P7, P9, P6, P08, P0, P, P, P, P70, P7, P77, P70, P7, P7, P7, P76, P7, P7, P76, P80, P8, P89 and P8. Mechanically Attached Metal Roof Panels Types Tite-Loc and Tite-Loc Plus roof deck panels (No. MSG min. gauge coated steel or 0.0 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Both types secured to hat sections+ or bearing plates++ with panel clips designed for the particular panel. For use in Design Numbers: P, P7, P0, P, P7, P08, P0, P, P70, P7, P7, P77, P70, P7, P7, P76, P7, P7, P76, P80, P8, P89, P8 +Hat-shaped member to be a minimum of 6 MSG, in. min. depth. Member to be fastened through the roof insulation to the steel roof deck with No. self-drilling and/or self-tapping fasteners. Spacing to be determined by the structural loading requirements. In addition, any compressible UL Classified glass fiber compressible blanket insulation with or without a vapor retarding facing may be used between the specified roof insulation and the metal roof panels. ++Bearing plate to be a minimum of 6 MSG. Member to be fastened through the roof insulation to the steel deck with No. self-drilling and/or self-tapping fasteners. HQ: 00 Tonne Road F: Annapolis Junction, MD 070 P: F: PAC Road P: F: rd Ave., NE, Ste Fridley, MN P: F: Northpoint Pkwy Ext, Bldg, Ste 00 Acworth, GA 00 P: F:
UNA-CLAD Metal Roof Systems
UNA-CLAD Metal Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and P Assemblies Factory Mutual Approvals (FM) Table of Contents 1.01 EXTERNAL FIRE RATINGS... 7 Assemblies are updated.
More informationUL 580 Construction No: ½ in Snap Lock w/ Clip
Test Type: Testing Authority: Test Name: UL 580 Construction No: 589 Underwriters Laboratories Wind Uplift Test Date: Test Completed By: Testing Laboratory Type: Width: Clip Spacing: Decking Construction:
More informationP1\C-CL \D PETERSEN ALUMINUM CORPORATION FL23953 METAL ROOFING CATEGORY INSTALLATION DETAIL BINDER TABLE OF CONTENTS:
p P1\C-CL \D P E T E R S E N PETERSEN ALUMINUM CORPORATION FL23953 METAL ROOFING CATEGORY INSTALLATION DETAIL BINDER TABLE OF CONTENTS: Snap-On Standing Seam Panel 24GA Steel &.032" Aluminum... 2-3 Snap-Clad
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationUL 580 Construction No: ½ in Mechanical Lock w/ Clip
Test Type: Testing Authority: Test Name: UL 580 Construction No: 588 Underwriters Laboratories Wind Uplift Test Date: Test Completed By: Testing Laboratory Panel Type: Greg Rezek Underwriters Laboratories
More informationCOMPOSITE SIDING INSTALLATION GUIDE
CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,
More informationAttachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016
Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016 SBCA has been the voice of the structural building components industry since 1983, providing
More informationSheet Steel Facts. Most common head design for self-drilling, self-tapping screws.
Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the
More informationMETAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS. Value through the Roof.
METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS Value through the Roof. Proven Performance. Huge Selection. Marco Quality. Value drives everything we do. That s why
More informationPROJECT INSTRUCTIONS Roofing
PROJECT INSTRUCTIONS Roofing This handout outlines some basic regulations contained within the 2015 Minnesota State Building Code, as well as other good building practices. However, this handout is not
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationThe City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.
Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 PART 1 GENERAL 1.1 SCOPE OF WORK.1 Total roof area approximately 1,312 m 2. The Work includes, but is not limited to:.1 Removal and disposal
More informationICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.
ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
More informationFASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS. Value through the Roof.
FASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS Value through the Roof. METAL-TO-METAL FASTENERS for CANADA QUIKDRILL METAL2METAL Value through the Roof. Reliable Self-Drilling Performance. Superior Marco Value.
More informationESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.
ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:
More informationROOFING City of Grand Rapids Building Safety Division
ROOFING City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Grand
More informationPRODUCT EVALUATION Effective July 1, 2009 RC-204
TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective
More informationFASTENERS BUILDING DEPARTMENT
FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationPerlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum
Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum u THE PERLOK CR 1.2 BASE SHEET FASTENER is a one piece unit, precision formed from G-90 galvanized steel,
More informationShapes Siding. Perfection Shingles. Chalk Line
Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationPerlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum
Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum u Uses THE PERLOK CR 1.2 BASE SHEET FASTENER is a one piece unit, precision formed from G-90 galvanized
More informationb) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the
PART 1 GENERAL 1) DESCRIPTION a) CertainTeed Symphony TM composite slate is an innovative roofing product that simulates the appearance, texture, and contours of traditional natural slate. It is a carefully
More informationFastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side
ITEM 1 DESCRIPTION OF BUILDING ELEMENTS Blocking between joists or rafters to top plate, toe 2 Ceiling joists to plate, toe 3 4 5 6 Ceiling joists not attached to parallel rafter, laps over partitions,
More informationMINI/MAXI-BATTEN. Panel Information. Detail Conditions. Flashing Profiles
Table of ontents Product Page No. Product Page No. Panel Information Profiles...PMB-2 Panel Overview...PMB-2 Flashing Profiles Eave...PMB- Extended Eave...PMB- leat...pmb- Offset leat...pmb- Starter...PMB-
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More informationLoad Tables, Technical Data and Installation Instructions
W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting
More informationAttachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016
Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder Installation Instructions Revised 9/2/2016 SBCA has been the voice of the structural building components industry
More information900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR
900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900
More informationPRIMED STRAND REVERSIBLE SHAKE
PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems
More informationRED DIAMOND SHINGLES Roof Installation Introduction:
RED DIAMOND SHINGLES Roof Installation Introduction: The guidelines set forth in this manual are intended for use with the application of Red Diamond shingles. Wallaba specie (Eperua Falcata) shingles
More informationDIVISION 6 WOOD AND PLASTICS
DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.
More informationA. Product Data: For each type of process and factory-fabricated product indicated.
SECTION 06100 - ROUGH CARPENTRY PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationTable of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1
Table of Contents DECRA Tile & Shake Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheets... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment... 4 Deck Preparation....
More informationGlasRoc Sheathing Type X
Wall / Fire-Rated Systems 3-5/8" (92 mm) Steel Studs ProRoc Steel Stud System 3-5/8" (92 mm) Steel Track 3-1/2" (89 mm) Glass Fiber or Mineral Wool Insulation GlasRoc Sheathing Type X UL Design U465 Cavity
More informationKS42 MF SERIES - HORIZONTAL INSTALLATION
CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF
More informationICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1790 Reissued September 1, 2012 This report is subject to renewal September 1, 2013. A Subsidiary of the International Code Council
More informationSECTION ASPHALT SHINGLES
SECTION 073110 - ASPHALT SHINGLES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Asphalt shingles. 2. Felt underlayment. 3. Self-adhering sheet underlayment. 4. Ice Shield Underlayment
More informationAsphalt Shingle Installation at Roof Edges, Intersections and Valleys
& Asphalt Shingle Installation at Roof Edges, Intersections and Valleys Abstract This updated document is intended to provide additional guidance and options for asphalt shingle installations at roof edges,
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More information4. Metal roof jacks at penetrations and attachments
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SECTION 07 61 00 METAL SHINGLE ROOFING - - - - - - - - - - -
More information1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels
SECTION 06 16 00 SHEATHING PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Roof and Wall Sheathing. B. Related Sections: Documents relating to the work of this section include, but are not limited to,
More informationTHE ENGINEERED WOOD ASSOCIATION
D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top
More informationThe better way to build TM. Installation Manual ROOF SIPs
The better way to build TM Installation Manual ROOF SIPs August 2017 ROOF SIPs Installation Manual Table of Contents Topics General Requirements.................................... 3 Materials..............................................
More informationBARRELL VAULT BATTENLESS
i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless
More informationSECTION SHEET METAL FLASHING AND TRIM
SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show
More informationFeatures 24 ga steel or 26 ga steel. Colors available on standard or premium and metallic. 16 to 24 o.c. On site factory made.
Strip Width Base Material Thickness Min Tensible Min Yield Coatings 16.00 to 24 in Steel.0128 to.027 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX539 The Nail Strip 1.5 (NS-150)
More informationSDWH TIMBER-HEX Screw
Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections, Including Ledgers Double-barrier coating provides corrosion resistance equivalent to hot-dip galvanization, making it suitable
More informationTECH BULLETIN SIP No Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) Roof/Ceiling: 1-Hour Rating
TECH BULLETIN SIP No. 2018 Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) ASTM E 119 (UL 263) tests have been conducted on R-Control SIPs to develop fire resistance assemblies.
More informationBarrel Vault Counter Batten and Batten
Barrel Vault Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationATOMIC. ASM Panel Brochure ARCHITECTURAL SHEET METAL,
ATOMIC ARCHITECTURAL SHEET METAL, INC. ASM Panel Brochure 3207 Labore Road Vadnais Heights, MN 55110 Phone: 651-646-1706 Fax: 651-646-1684 atomic@atomicsheetmetal.com 1 of 1Page 0 of 0 ARCHITECTURAL SHEET
More informationMetal Roof Installation Manual. Chapter 14: Fasteners
Metal Roof Installation Manual Chapter 14: Fasteners Chapter 14: Fasteners Chapter Contents 14. Introduction... 14-1 14.1 Fastener Parts and Installation... 14-1 14.1.1 Points... 14-1 14.1.2 Heads... 14-1
More informationProduct Information & Installation Instructions
Product Information & Installation Instructions TUFF-STRAND TM OSB Sheathing OSB Structural Panels from MARTCO Installation Instructions: Site-Built and Modular Construction Important Notice to Buyers
More informationTuff-Rib Install Guide
Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.
More informationB. Related Sections: The following Sections contain requirements that relate to this Section:
SECTION 07311 - ASPHALT SHINGLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationFOCUSING ON FASTENERS
FOCUSING ON FASTENERS 36 January 2010 www.professionalroofing.net MAKE INFORMED DECISIONS WHEN SELECTING FASTENERS BY JOAN P. CROWE, AIA Fasteners can be used with almost every roof system component and
More informationInstallation Instructions
Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General
More informationInstallation Instructions
Installation Instructions SLICKER MAX RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Top of Wall Detail 5 Bottom of Wall Detail 6 Wall Corner Detail
More informationINSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN
MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE
More informationInstallation Instructions for Siding
Smart-Shingle TM System "The new smart way to install cedar shingles." - This Old House Installation Instructions for Siding V3.2 INSTALLATION GUIDE MARKS Shingle-Strip 0 1 2 3 4 5 6 7 8 9 10 11 12 13
More informationInstallation Manual for Thermo Panel
Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on
More informationRESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017
RESIDENTIAL ADDENDUM NUMBER ONE August 28, 2017 The following additions to, deletions from, and clarifications of the Contract Documents govern insofar as they apply and shall take precedence over those
More informationINSTALLATION MANUAL STORAGE
IMVersion 1.1 INSTALLATION MANUAL GENERAL GUIDE: The information in this IM is intended to serve as a general guide to proper installation with no warranties intended or implied. Prime Panels assumes no
More informationSECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY
SECTION 07312 PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. This Section Includes the following: 1. Endureed Dominica PVC thatch shingles. 2. Self- adhering sheet underlayment. B. Related
More informationAdorn Mortarless Stone Veneer Installation Natural Concrete Products
Adorn Mortarless Stone Veneer Installation Adorn Mortarless Stone Veneer can be used on new or existing construction. Adorn is nailed or screwed onto the wall; therefore no brick ledge is required. Adorn
More informationT-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY
August 10, 2010 T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY ST - T-BRACE 2 R MiTek Industries, Chesterfield, MO Page 1 of 1 Note: T-Bracing / I-Bracing to be used when continuous lateral bracing is impractical.
More informationREPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1360 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00
More informationTechnical Note No. 026
Technical Note No. 026 Strand Substrate Installed Vertically for Board & or Board-on-Board Applications This Technical Note is an addendum to the Strand Substrate Application Instructions and Trim and
More informationDECRA Shingle Installation Guidelines
Installation Guide DECRA Shingle Installation Guidelines General Instructions Failure to use these guidelines may void the product warranty. Local building codes may require additional application techniques
More informationAsh Brook Golf Course Scotch Plains, New Jersey
SECTION 062013 - EXTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationB. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.
SECTION 06 16 43 GYPSUM SHEATHING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior GMF gypsum sheathing. 2. Joint treatment materials. 3. Panel and penetration joint and fastener treatment.
More informationFLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.
Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. GulfRib Roof Panel over over 15/32 Plywood Florida Product Approval #11651.21 R3 Florida Building Code 2017 Per Rule 61G20-3 Method:
More information1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS
General This Installation Instruction document for Owens Corning Berkshire roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with
More informationFLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.
26 GUAGE PANEL OVER 1X4 WOOD PURLINS OVER 15/32 PLYWOOD NO. 11651.14 R2 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. 5V Crimp Roof Panel over over 15/32 Plywood Florida Product
More informationKuraStone TM Installation Guide
Installation Guide Read these installation guidelines completely and thoroughly before beginning installation. Construction Requirements KuraStone pieces can be installed on braced wood or steel stud (18
More informationThe available roof cover choices are listed below: Fiberglass, Translucent Panels Steel. Shingles, Asphalt/Fiberglass, Irregular Pattern
Navigation Roof Cover Roof Cover The different choices available for roof materials are listed below. Enter the percentage of each roof material found on the home. NOTE: Typically you would enter a percentage
More informationSCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION
test TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Cold-Formed Steel Engineers Institute Washington, DC www.cfsei.org 866-465-4732 SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION
More informationRe-Roofing Policy SPECIAL REQUIREMENTS AND NOTES
CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8949 Building Safety Division (209) 456-8550 Planning Division (209) 456-8500 Public Works/Engineering
More informationTechnical Note No. 028
Technical Note No. 028 38 Series Strand Substrate for Board & Batten Applications This Technical Note provides guidance for the application of 38 Series Strand Substrate for Board & Batten Applications.
More informationSECTION ROUGH CARPENTRY
SECTION 06100 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide Rough Carpentry as shown and detailed on the Drawings and
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationSECTION ASPHALT SHINGLES
SECTION 07311 ASPHALT SHINGLES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Asphalt shingle roofing. 2. Flexible sheet membranes for eave protection, underlayment, and valley protection. 3. Associated
More informationConstruction details: Master-C type profiles and joints:
Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16
More informationInstallation Instructions
Installation Instructions SLICKER CLASSIC RAINSCREEN Page List of Approved Compatible Products 2 Nail Selection Guide 3 General Installation 4 Insulation Board Installation 5 EIFS Installation 6 Top of
More informationConstruction No. 90. Construction No. 90
Page 1 of 9 Page Bottom Construction No. 90 TGKX.90 Roof Deck Constructions Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the
More informationTECHNICAL BULLETIN. 7/2017 CertainTeed Corporation
TECHNICAL BULLETIN CEDAR IMPRESSIONS INDIVIDUAL 5 SAWMILL SHINGLE FLARE INSTALLATION INSTRUCTIONS (STANDARD WALL, TURRET WALL, OUTSIDE CORNER 90⁰;BAY/BOW) Cedar Impressions Individual 5 Sawmill Shingles
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationSECTION CARPENTRY
SECTION 06100 CARPENTRY PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Carpentry work including grounds, nailers, blocking, miscellaneous framing, plywood backing panels, plywood sheathing, preservative
More informationSECTION ROUGH CARPENTRY
SECTION 06 10 00- ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Contracting Requirements and Division 1 Specification Sections, apply
More information1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Steep-Slope Roof Systems
More informationSHEET METAL FLASHING AND TRIM Christ on the Mountain
SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Compatibly with the bumping of flashings and trim as identified in the Membrane Roofing Section 075000.
More informationTABLE OF CONTENTS A-1
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE
More informationMETAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof.
METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD Value through the Roof. Reliable Self-Drilling Performance. Superior Marco Value. Value drives everything we do. That s why our exclusive Weather-Tite
More informationMulti-Institutional Academic Health Science & Research Center Evansville, IN
SECTION 06 1053 - MISCELLANEOUS ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Division 01 Specification
More information400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationCOMPATIBILITY OF FASTENERS
COMPATIBILITY OF FASTENERS TECHNICAL BULLETIN Vol. 4, No. 2 NOVEMBER 2011 This bulletin applies to conditions where fasteners are not provided by Metl-Span. Profiled metal roof or wall panels rely upon
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More information