2 August 2017 ROOF SIPs Installation Manual Table of Contents Topics General Requirements Materials Electrical Wiring Interior Finish Exterior Cladding Materials Estimation Details Air Barrier Details for Air Barrier Sealants AB-1 Air Barrier Details for Sealing SIP Connections AB-2 Vapour Barrier Details for Vapour Sealing SIP Connections.... VB-1 Typical Roof Ridge R-1 Roof Ridge Details for 12/12 Pitch Roof R-2 Beam Pocket Detail R-3 Roof Valley & Intermediate Roof Support R-4 Eave Detail and Roof Support at Exterior Wall R-5 Typical Sloped Roof Assembly R-6 Sloped Roof Assembly with Ridge Beam R-7 Flat Roof Assembly R-8 Skylight Opening & Assembly R-9 Typical Roof Connection Sections (Roof to Wall) R-10 Roofing Applied to SIPs R-11 Flat Roofing Applied to SIPs R-12 LED Pot Light Installation in Ceiling SIPs R-13 Roof Overhang Eave Details (Timberframe) R-TF-1 Roof Overhang & Rake (Timberframe) R-TF-2 Roof SIP - Installation Manual 2
3 August 2017 ROOF SIPs Installation Manual 1. General Requirements 1.1 Scope The basic design and construction requirements for the Thermapan Structural Insulated Panel (SIP) roof system is set forth in this specification. Criteria for materials, environmental control, design loads, and structural design are included. Where requirements are based on internationally recognized standards and specifications, these standards and specifications are referenced without elaboration. Installers shall reference engineering design package for fastening arrangements. 2. Materials 2.1 The Thermapan Roof SIP is composed of an expanded polystyrene (EPS) foam core laminated between two layers of oriented strand board (OSB) with a structural adhesive. 2.2 Framing Lumber shall be DOC PS 20 or NLGA No.2 or better. 2.3 Wire nails, ring nails, spikes and staples shall conform to CSA B111 or ANSI/ASME B Wood screws shall conform to ANSI/ASME B SIP screws shall conform to ICC-AC Caulking Compounds shall conform to CAN/CGSB or ASTM C Polyethylene Sheeting shall conform to CAN/CGSB-37.2, CAN/ CGSB-37.16, or ASTM D Low expansion foam seal shall conform to AAMA Structural adhesive shall conform to CAN/CGSB 71GP26, APA AFG-01 or ASTM D Electrical Wiring 3.1 An optional furring for electrical passage should be fastened to the underside of the roof SIP between the vapour barrier and the interior finish. See details R-1, R-4 and R-5. Roof SIP - Installation Manual 3
4 August Interior Finish 4.1 The interior of the roof SIP can be finished with any of the common required building code materials. It is recommended that the SIP joints and connections be sealed as per Details AB-1, AB-2 and VB Exterior Roofing 5.1 Consult your local building code and refer to details R-11 and R-12 for roofing applied to SIPs. Roof SIP - Installation Manual 4
5 August 2017 MATERIALS ESTIMATING Roof (Vaulted Ceiling) Estimation Only Lumber Requirements: Perimeter of roof or fascia length Caulking and Sealant Requirements: Every 1200 sqft (111 m 2 ) of SIP equals 1 case of Expandable Foam Every 2000 sqft (185 m 2 ) of SIP requires 1 case of Sealant Fasteners: Recommend 2 (50mm) Ring nail or 2 (50mm) screws for connection to panel ~ 1.25 times the square footage of SIPs... nailing of spline SIP screws use 40% of Roof square footage Roof SIP - Installation Manual 5
6 AIR BARRIER RECOMMENDED DETAILS FOR AIR BARRIER SEALANTS All sealants, FOAM (A) or CAULKING (B), should be applied onto the SIP in a continuous rectangular pattern along the outer most edge of the area to be sealed. (A) A low expansion FOAM SEALANT should conform to the AAMA standard. Apply a 1/2 inch or a 12.5 mm diameter of a continuous bead of expandable foam sealant onto the SIP: Expandable Foam Sealant Bead EPS (B) A CAULKING SEALANT should conform to ASTM C and/or CAN/CGSB M. Apply a 3/8 inch or a 10 mm diameter continuous bead of caulking onto the lumber spline: CAULKING (CONTINUOUS BEAD) Caulking Bead LUMBER STUD OR SPLINE AIR BARRIER DETAILS FOR AIR BARRIER SEALANTS DWG. No. NOVEMBER AB-1
7 AIR BARRIER RECOMMENDED DETAILS FOR SEALING SIP CONNECTIONS (1) Foam to Foam: Use a low expansion foam sealant. 1/4 (6 mm) GAP FOAM SEALANT FOAM SEALANT SIP SPLINE JOINT SEE VAPOUR BARRIER DETAIL (VB-1) BUTT JOINT (2) Foam to Wood: Use a low expansion foam sealant. PLATES SECTION LUMBER SPLINES CAP TOP PLATE FOAM SEALANT CAULKING (SEE WOOD TO WOOD) FOAM SEALANT BOTTOM PLATE LUMBER SPLINE, END STUD OR JOIST (3) Wood to Wood: Use caulking and a low expansion foam sealant. CORNER DETAIL PLAN LUMBER SPLINE FOAM SEALANT SEE VAPOUR BARRIER DETAIL (VB-1) FOAM SEALANT FOAM SEALANT CAULKING (SEE AB-1) CAULKING (SEE AB-1) AIR BARRIER DETAILS FOR SEALING SIP CONNECTIONS MAY 2009 DWG. No. AB-2
8 VAPOUR BARRIER RECOMMENDED DETAILS FOR VAPOUR SEALING SIP CONNECTIONS The function of a vapour barrier is to control the entry of water vapour into the building assembly. Vapour barriers should not be confused with an air barrier. All SIP seams and connections must be VAPOUR SEALED from the INTERIOR. These are recommended vapour barrier methods: OSB EXTERIOR INTERIOR CONTINUOUS 6 MIL POLY OVER ENTIRE SIP ASSEMBLY SEE AIR BARRIER DETAIL (AB-2) 6 MIL POLY STRIP CAULKED TO OSB SEE AIR BARRIER DETAIL (AB-2) CONTINUOUS 6 MIL POLY RECOMMENDED 6 MIL POLY STRIPS & CAULKING EXTERIOR INTERIOR CAULKING SEE AIR BARRIER DETAIL (AB-2) OSB SEE AIR BARRIER DETAIL (AB-2) SIP TAPE CAULKING SIP TAPE VAPOUR BARRIER DETAILS FOR VAPOUR SEALING SIP CONNECTIONS NOVEMBER 2010 DWG. No. 1 VB-1
9 SIP SCREW ( SEE FASTENING TABLE) FOAM SEALANT VAPOUR SEALED AS PER VB-1 CHAMFER BLOCKING (WEDGE) OPTIONAL FURRING FOR ELECTRICAL PASSAGE INTERIOR FINISH RIDGE SECTION (WITH RIDGE BEAM) STRUCTURAL SUPPORT AS REQUIRED SIP SCREW (SEE FASTENING TABLE) ADJUST FRAMING MEMBER AS REQUIRED FOAM SEALANT VAPOUR SEALED AS PER VB-1 CAULK TO PANEL INTERIOR FINISH OPTIONAL FURRING FOR ELECTRICAL PASSAGE RIDGE SECTION (NO RIDGE BEAM) NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS ROOF RIDGE DETAILS FEBRUARY DWG. No. R-1
10 SIP SCREWS CAULK TO PANEL 6 MIL POLY VAPOUR BARRIER RIDGE SECTION (TYPICAL RIDGE BEAM) SIP SCREWS CAULK TO PANEL RAFTER & BEAM BY OTHERS FOR RAFTER & BEAMS (DESIGNED BY OTHERS) 6 MIL POLY NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS SECTIONS - ROOF RIDGE DETAILS FOR 12/12 PITCH ROOF FEBRUARY 2012 R-2 DWG. No. R-2
11 CHAMFER BLOCKING FOAM SEALANT SIP SCREW SIP SCREW VAPOUR SEALED AS PER VB-1 CAULK TO PANEL TOP PLATES RIDGE BEAM AS REQUIRED POST (BUILT-UP OR SOLID) PANEL JOINT WALL P ANEL RIDGE BEAM & POST POCKET NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS BEAM POCKET DETAIL DECEMBER DWG. No. R-3
12 FOAM SEALANT SIP SCREW CAULK TO PANEL VAPOUR SEALED AS PER VB-1 CHAMFER BLOCKING INTERIOR FINISH OPTIONAL FURRING FOR ELECTRICAL PASSAGE ROOF VALLEY STRUCTURAL SUPPORT AS REQUIRED SIP SCREWS SIP SCREW FOAM CHAMFER BLOCKING OPTIONAL FURRING FOR ELECTRICAL PASSAGE INTERIOR FINISH PANEL JOINT AT ROOF SUPPORT WEDGE OR BEAM CHAMFERED AT TOP INTERIOR FINISH PANEL CONTINUES OVER ROOF SUPPORT STRUCTURAL SUPPORT AS REQUIRED NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS ROOF VALLEY & INTERMEDIATE ROOF SUPPORT JANUARY DWG. No. R-4
13 CHAMFER BLOCKING (INSERT AFTER ROOF PANELS ARE IN PLACE) SIP SCREW SEE FASTENING TABLE CAULK TO PANEL FASCIA FOAM SEALANT VAPOUR SEALED AS PER VB-1 INTERIOR FINISH FOAM OPTIONAL FURRING FOR ELECTRICAL PASSAGE CAULK FOAM SEALANT FASCIA CAP & PLATE BLOCKING SOFFIT FRAMING OVERHANG (SEE TABLE R-T-3) WALL PANEL ROOF SUPPORT NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS EAVE DETAIL & ROOF SUPPORT AT EXTERIOR WALL FEBRUARY DWG. N o. R-5
14 SECTION A-A SEE FASTENING TABLE AND DETAIL BELOW EPS CORE OSB SKIN VAPOUR SEALED AS PER VB-1 A A SEE SECTION B BELOW SPLINE ROOF ASSEMBLY SECTION B SIP SPLINE BLIND FASCIA (SITE) FASCIA WEDGE FOR PLUMB CUT (SITE) NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS. NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS TYPICAL SLOPED ROOF ASSEMBLY FEBRUARY DWG. No. R-6
15 SEE DETAIL R-1 OR R-2 A A SEE DETAIL R-4 OR R-5 BLIND FASCIA (SITE) FASCIA WEDGE FOR PLUMB CUT (SITE) ROOF ASSEMBLY SECTION A-A SIP SPLINE SIP SPLINE LUMBER SPLINE FOAM SEALANT OR CAULKING (SEE AB-1) NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS. NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS SLOPED ROOF ASSEMBLY WITH RIDGE BEAM FEBRUARY DWG. No. R-7
16 A A INSTALL FASCIA BOARD ON SITE SPLINE SEE SECTION B BELOW EPS CORE SECTION A-A SEE FASTENING TABLE SECTION B ISOMETRIC ROOF ASSEMBLY GENERIC DETAIL FOR FLAT ROOF FOAM SEAL 3 FOAM CORE SPLINE OSB SKIN CAULK VAPOUR SEALED AS PER VB-1 VAPOUR SEALED AS PER VB-1 NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS. NOTE: FASTENING TABLE ON CONNECTION DESIGN (CD) SHEET OF ENGINEERED SHOP DRAWINGS FLAT ROOF ASSEMBLY FEBRUARY DWG. No. R-8
17 ROOF JOISTS ATTACHED BY HANGERS OR SIDE NAILING OPTIONAL JOISTS OPTIONAL 1.5 RECESS TYPICAL U.N.O. 1.5 OR 3 RECESS SEE SKYLIGHT MANUFACTURER S DETAIL HANGER OR NAILS DOUBLE SPLINE JOIST SKYLIGHT OPENING & ASSEMBLY FEBRUARY DWG. No. R-9
18 FLASHING SECURE END PLATE REMOVE FOAM FROM ROOF PANEL AS TO INSTALL NAILER AND LEDGER BOARD TO MATCH WALL BOARD. LEDGER SECURED TO STUDS OPTION 1 FLASHING EMBEDDED MIN. 1" IN MASONRY SECURE TO NEW STUD WALL WITH SIP SCREWS WATER RESISTANT MEMBRANE NEW STUD WALL SECURED TO EXISTING STRUCTURAL WALL EXISTING WALL OPTION 2 NEW ROOF TO EXISTING WALL TYPICAL ROOF CONNECTION SECTIONS (ROOF TO WALL) DWG. No. FEBRUARY R-10
19 S (TWO SHOWN) ASPHALT SHINGLES NON-ADHERING BREATHABLE ROOFING UNDERLAYMENT INSTALLED AS PER MANUFACTURER S INSTRUCTIONS DRIP EDGE FASCIA COVER 2X_ FASCIA BOARD DRIP EDGE FASCIA BOARD FASCIA COVER FASCIA WEDGE FOR PLUMB CUT 2X_ BLIND FASCIA STARTER SHINGLE INSTALLED AS PER MANUFACTURER S INSTRUCTIONS METAL ROOFING OR CEDAR SHAKES S (TWO SHOWN) NON-ADHERING BREATHABLE ROOFING UNDERLAYMENT INSTALLED AS PER MANUFACTURER S INSTRUCTIONS DRIP EDGE FURRING INSTALLED AS PER MANUFACTURER S INSTRUCTIONS 2X_ FASCIA COVER FASCIA BOARD DRIP EDGE FASCIA BOARD FASCIA COVER FASCIA WEDGE FOR PLUMB CUT 2X_ BLIND FASCIA METAL ROOFING OR SHAKES INSTALLED AS PER MANUFACTURER S INSTRUCTIONS NOTE: VENTILATION OF SIP ROOF NOT REQUIRED. ROOFING APPLIED TO SLOPED SIPS DWG. No. AUGUST R-11
20 NON-ADHERED MEMBRANE (EPDM, PVC, TPO, ETC.) FASTENERS INTO OSB PROTECTIVE SHEATHING OR MEMBRANE AS REQUIRED OSB EPS ADHERED ROOFING MEMBRANE TORCHED ON OR GLUED ON ROOFING MEMBRANE FASTEN PROTECTIVE SHEATHING LAYER (OSB, PLYWOOD) WITH GLUE, NAILS OR SCREWS OSB EPS NOTES: SIP SURFACE TO BE DRY. INSTALL MEMBRANE ACCORDING TO MEMBRANE MANUFACTURER S DETAILS AND CONFORM TO REQUIREMENTS OF LOCAL BUILDING CODE. FLAT ROOFING APPLIED TO SIPS NOVEMBER 2011 DWG. No. R-12
21 * DRIVER BOX WIRING LED RECESS CEILING FIXTURE* STRAPPING INTERIOR FINISH * FIXTURE SPECIFICATIONS FIXTURE TO HAVE AMBIENT OPERATING TEMPERATURE +140F(+40C) MAXIMUM INSTALL AS PER MANUFACTURERS SPECIFICATIONS LED POT LIGHT INSTALLATION IN CEILING SIPS JANUARY 2017 DWG. No. R-13
22 UNFINISHED EAVE DETAIL FOR LEVEL SOFFIT RAFTER RECESS FOR INLAY FOAM SEALANT WALL PANEL VAPOUR SEALED AS PER VB-1 2 NAIL INTO TIMBERFRAME POST 1/2 DRYWALL CAULK TO PANEL FINISHED EAVE DETAIL WITH LEVEL SOFFIT RAFTER TAIL AND INLAY INSTALLED ON GROUND - SCREWED FROM TOP AND BOTTOM RAFTER 16" O/C RAFTER 1/2 " DRY WALL CAULK TO PANEL FINISHED FASCIA KICKER VAPOUR SEALED AS PER VB-1 INSULATION SUGGESTED POST FINISHED SOFFIT LEDGER WALL PANEL NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS. ROOF OVERHANG EAVE DETAILS (TIMBERFRAME) 8020 DWG. No. FEBRUARY R-TF-1
23 HURRICANE STRAP OSB "TIE" CONVENTIONAL LADDER FOAM SEALANT BEAM / RAFTER VAPOUR SEALED AS PER VB-1 BUILT OUT OPTION POPULAR FOR ROOFS WITH COMMON RAFTER SYSTEMS AND PANEL ORIENTED VERTICALLY WALL PANEL NOTE: SCREW AND GLUE LADDER TO WALL PANEL FOAM HELD BACK FOR RAKE BLOCKING 2X_ INLAY RAKE BLOCKING FOAM SEALANT RAFTER / BEAM VAPOUR SEALED AS PER VB-1 RUN-BY OPTION, POPULAR FOR ROOFS WITH PRINCIPAL RAFTERS AND PURLINS AND PANELS ORIENTED HORIZONTALLY WALL PANEL NOTE: REFER TO AIR BARRIER (AB-2) AND VAPOUR BARRIER (VB-1) DETAILS FOR SEALING SIP CONNECTIONS. ROOF OVERHANG & RAKE (TIMBERFRAME) 8020 DWG. No. MAY R-TF-2
Sections & Details VOCABULARY
1 Sections & Details VOCABULARY 1 ROOF FRAMING DETAIL RIDGE BOARD SHEATHING SHINGLES WEB FASCIA RAFTER (chord) SOFFIT SHEATHING STUD INSULATION DOUBLE TOP PLATE CEILING JOIST 2 FOUNDATION DETAIL STUD SHEATHING
More informationInstallation Instructions
Installation Instructions XTRACTOR VENT X18 / X18 XTRA / XLP Page X18 and X18 Xtra General Installation 2 XLP General Installation 3 Asphalt Fiberglass Shingles Detail 4 Ridge Beam Detail 5 Hip Roof Detail
More informationInstallation Instructions
Installation Instructions SHARK VENT XLP / XTRA Page Installation Considerations 3 Shark Vent XLP & Xtra General Installation 4 Steep Pitch Guidelines 5 Asphalt Shingles Detail 6 Ridge Beam Detail 7 Hip
More informationInstallation Instructions
Installation Instructions XTRACTOR VENT X18 / X18 XTRA / XLP Page Installation Considerations 3 X18 and X18 Xtra General Installation 4 XLP General Installation 5 Steep Pitch Guidelines 6 Asphalt Shingles
More information12x12 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationAsphalt Shingle Installation at Roof Edges, Intersections and Valleys
& Asphalt Shingle Installation at Roof Edges, Intersections and Valleys Abstract This updated document is intended to provide additional guidance and options for asphalt shingle installations at roof edges,
More informationMaterials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel
This 8 12-ft. shed features a simple gable roof, double doors, and side and rear windows for natural lighting. With full-height walls and doors, there's ample room for storing large items or creating a
More informationBUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame
BUILDING THE BASIC SHED Step A: Build the Foundation & Floor Frame 1. Excavate the building site and add a 4" layer of compactible gravel. If desired, add an extension to the base for the optional wood
More information8x8 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationWith Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans
12 X 8 Shed Plans With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans Blueprints And Diagrams Instructions For Building The Shed
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationInstallation Instructions
Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e H O W B U I L D S H E D. C O M Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More informationHOW TO BUILD A 12X8 SHED
HOW TO BUILD A 12X8 SHED With Illustrations, Drawings & Step By Step Details Note: This is a sample plan from RyanShedPlans. All other plans in our collection goes indepth with more details, more instructions,
More informationInstallation Guide - Evolution Series Wood Siding
Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration
More information10x10 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationInstallation Instructions
Installation Instructions ROLL VENT STANDARD / METRIC Page Installation Considerations 3 Roll Vent Standard General Installation 4 Roll Vent Metric General Installation 5 Steep Pitch Guidelines 6 Asphalt
More informationSG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationFastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side
ITEM 1 DESCRIPTION OF BUILDING ELEMENTS Blocking between joists or rafters to top plate, toe 2 Ceiling joists to plate, toe 3 4 5 6 Ceiling joists not attached to parallel rafter, laps over partitions,
More informationInstallation Instructions for Standard Lap and Self-Aligning Lap Siding
Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationShapes Siding. Perfection Shingles. Chalk Line
Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter
More informationROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION
ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION 1. 2. 3. Scope 1.1 This application standard provides the minimum installation criteria for wood
More informationInstallation Guide. Please read before installing SIPs Kit. 1 Method Statement for the erection of a SIPS Industries Kit Materials...
30a Renewable Chase Bibra Lake WA 6163 Tel: (08) 9494 2211 Fax: (08) 9494 2202 Email: info@sipsindustries.com.au Web: www.sipsindustries.com.au Installation Guide Please read before installing SIPs Kit.
More informationROOFING APPLICATION STANDARD (RAS) No. 130
ROOFING APPLICATION STANDARD (RAS) No. 130 1. Scope 1.1 This application Standard provides the minimum installation criteria for wood shingles and shakes. 2. Definitions 2.1 For definitions of terms used
More informationMaterial List for Log Complete Packages
Material List for Log Complete Packages DAYLIGHT BASEMENT EXTERIOR WALLS ( If Applicable ) 2X6 Pressure Treated Sills With 6" Foam Sill Sealer 2X6 K.D. Spruce Plates And Studs 2X10 K.D. Spruce Headers
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationInstallation Instructions for Panel Siding and Soffit
Installation Instructions for Panel Siding and Soffit 7/16 in. Panels Include: Sturdy Panel, Square Edge, 3/4 in. Channel and Reverse Board and Batten (RB&B) 1/2 in. Panels Include: Adobe Shiplap and 808
More informationThe City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.
Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 PART 1 GENERAL 1.1 SCOPE OF WORK.1 Total roof area approximately 1,312 m 2. The Work includes, but is not limited to:.1 Removal and disposal
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationPRIMED STRAND REVERSIBLE SHAKE
PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems
More informationAppendix C: Cheat Sheets Construction Manual
Appendix C: Cheat Sheets Construction Topic Section Reference Nails Not Applicable Lumber Not Applicable Cap Plate 4.2.10 Mud Sill Anchors 4.5.1 HVAC 4.5.4 Attic Access 4.5.5 Deadwood 4.5.6 Blocking 4.5.7,
More informationF-WAVE REVIA SYNTHETIC ROOFING SHINGLES
F-WAVE REVIA SYNTHETIC ROOFING SHINGLES Installation Manual for Steep-Slope Residential Installations For support with all other Steep-Slope Installations, please call F-Wave Technical Support at 888-GO-FWAVE.
More informationGarage Design Guide. October 2018
Garage Design Guide October 2018 The Corporation of the Township of Hamilton 8235 Majestic Hills Drive, P.O. Box 1060, Cobourg Ontario K9A 4W5 Tel: 905-342-2810 Fax: 905-342-2818 Email: Tim Jeronimus (Chief
More informationASPHALT T E C H N O L O G I E S
ASPHALT T E C H N O L O G I E S Evaluation of Active Ventilation Products Inc. Aura-D (AV-24) Ventilator in Accordance With FLORIDA BUILDING CODE PROTOCOL TAS 100(A)-95 TEST PROCEDURE FOR WIND AND WIND
More informationFASTENERS BUILDING DEPARTMENT
FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and
More informationTurada Hardwood Shingles and Shakes Installation instructions
1. General 1.1 Maximum Exposure: Maximum exposure for wood shingles and shakes shall comply with Table 1 herein, unless specifically specified in the roof assemblies Product Approval. 1.2 Solid and Spaced
More informationInstallation and Finishing Manual for Polyurethane (PUR) Core Structural Insulating Panels
Installation and Finishing Manual for Polyurethane (PUR) Core Structural Insulating Panels THE MURUS COMPANY, INC. P.O. BOX 220, 3234 ROUTE 549 MANSFIELD, PENNSYLVANIA, USA 16933 Toll free: 800-626-8787
More informationConstruction details: Master-C type profiles and joints:
Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationA P P L I C A T I O N I N S T R U C T I O N S
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More information3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25
3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 1 Directions For Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to building code and local amendments.
More information6x6 Shed Plans and Building Guide
Page 1 Legal 2018 Zac Spade & Christopher D. Brown. All Rights Reserved For information about special discounts available for bulk purchases, sales promotions, fundraising and educational needs, contact
More informationRoof 50% REDUCE STORM DAMAGE
redo the roof...... it s a good idea to replace the roofing felt, too. With the felt off, you can see the roof deck, or sheathing. Roof decking gives you something to nail the shingles to, but it also
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More informationCFDTT-01. Control Joint Study (General)
Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area
More informationTechnical Note No. 028
Technical Note No. 028 38 Series Strand Substrate for Board & Batten Applications This Technical Note provides guidance for the application of 38 Series Strand Substrate for Board & Batten Applications.
More informationSECTION ROUGH CARPENTRY
SECTION 06 10 00- ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Contracting Requirements and Division 1 Specification Sections, apply
More informationInstallation Instructions for Old Mill Shingle and Designer Shake Lap Siding
Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Includes: Cove, Craftsmen Staggered, Diamond, Fish Scale, Octagon, Round and Old Mill Shingle Lap Important: Read and understand
More informationInstallation Guide for Timber Framed Homes
Installation Guide for Timber Framed Homes 1 Table of Contents Introduction Page 3 Panel off Loading.Page 4 Panel Storage Page 5 Sip Tools...Pages 6 & 7 Building a Structural House Boards...Page 8 Field
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More information4. Metal roof jacks at penetrations and attachments
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SECTION 07 61 00 METAL SHINGLE ROOFING - - - - - - - - - - -
More informationSmartVent Eave Edge Installation Instructions
SmartVent Eave Edge Installation Instructions STEP 1: Cut a slit 1 wide (or a series of 1 ¾ holes at 3 on center) into the roof decking 6 to 7 up from the drip edge. SmartVent is rated 9NFA. Ensure drip
More informationCERACLAD.
CERACLAD 4. Horizontal Application (Wood Structure) Instructions and Details Siding Panel Installation Accessories Installation Overview Starter Bar Installation Install s Installation
More informationTHERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)
THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE) fig.3 Casement, Awning, Fixed Casement, Direct-Set, Double-Hung, Single-Hung & Horizontal Slider Windows Materials
More informationBARDOLINE INSTALLATION INSTRUCTIONS
BARDOLINE INSTALLATION INSTRUCTIONS www.onduline.com CONTENTS General conditions Material requirements Terms Estimating shingle requirements Roof preparation Shingle application 9 GENERAL CONDITIONS ONDULINE
More informationAIA Specification. Section Slate Shingles PART 1 GENERAL
AIA Specification Section 07315 Slate Shingles PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDIVISION 6 WOOD AND PLASTICS
DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.
More informationMAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.
PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER
More informationROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION
ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive
More informationROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION
ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive
More informationNEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
More informationExterior Wall Fastener Schedule
City of Republic Community Development Department Exterior Wall Fastener Schedule REVISION DATE: JANUARY 2017 Design and construction (2012 IRC Section R602.3): Exterior walls of wood frame construction
More information3.1 General Provisions
WOOD FRAME CONSTRUCTION MANUAL 107 3.1 General Provisions 3.1.1 Prescriptive Requirements The provisions of this Chapter establish a specific set of resistance requirements for buildings meeting the scope
More informationBuilding An Outdoor Playhouse
Building An Outdoor Playhouse If you want to give the children in your family their own retreat and improve your do-it-yourself skills at the same time, this playhouse is the perfect project for you. Not
More informationInstallation Guide Classic Series Wood Siding
Installation Guide Classic Series Wood Siding Please read the following instructions prior to beginning your installation. The following installation guidelines have been produced in accordance with the
More information1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Steep-Slope Roof Systems
More informationSanta Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide
Alumawood TM Newport with MAXX Panel TM Installation Guide Santa Fe Cover INSTALLATION GUIDE Whatever the weather, you can enjoy the sophisticated charm of a lattice cover. The Santa Whatever the weather,
More informationONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S
ONDUVILLA The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S 1 INSTALLATION INSTRUCTIONS Even though ONDUVILLA is easy to install, it is important to read through these
More informationInstallation and Finishing Manual for PUR Structural Insulating Panels
TM STRUCTURAL INSULATING PANELS Installation and Finishing Manual for PUR Structural Insulating Panels THE MURUS COMPANY, INC. P.O. BOX 220, 3234 ROUTE 549 MANSFIELD, PENNSYLVANIA, USA 16933 Toll free:
More informationE-Z BUILD SHED GUIDE 12' 12' 12' 16' 12' 20'
E-Z BUILD SHED GUIDE 12' 12' 12' 16' 12' 20' BUILD You can construct your own E-Z frame shed with the help of this step by step guide. North American softwood dimensional lumber sizes: Nominal Actual in
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised July 27, 2012 the North Dakota with pocket doors 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This
More informationAppendix A. Additional Information ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF)
Appendix A Additional ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF) Considering the proprietary nature of Insulated Concrete Forms (ICF) and the number of ICF manufacturers currently
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 12, 2017 the Arlington Building Size 12' x 16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted.
More informationSuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter
SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm
More informationVENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4
GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24" C/C MAX. BUTYL
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 13, 2017 the Belmont Building Size 12' x 16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted.
More informationSECTION WOOD SHINGLES
SECTION 07 31 29.13 WOOD SHINGLES SPEC WRITER NOTES: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. This guide specification does not include requirements
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationMaterial Description Qty Units Cost Total SQUARE FOOTAGE TOTAL Area 1692 sqft
Material Report for plan: Willowdale A Page 1 of 7 SQUARE FOOTAGE TOTAL Area 1692 sqft EXCAVATION & FOUNDATION EXCAVATION & BACKFILL Conc. Footing (volume) 5 m³ 122.50 612.50 Conc. Footing (length) 6"x20"
More informationChapter 51: Sidewall Overhang(s) Only - Enclosed
Chapter 51: Sidewall Overhang(s) Only - Enclosed Most Common Mistakes: 1. Incorrect eave height. 2. Placing eave girt below truss tails. 3. Fascia board top edges not bevel cut to match roof slope. 4.
More informationInstallation Manual for Thermo Panel
Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised March 6, 2017 the Arlington Building Size 12' x 24' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive - Greenville, PA 16125 This manual is copyrighted.
More informationTECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING
TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TABLE OF CONTENTS This installation guide provides detailed step-by-step instructions for do-it-yourself projects. We invite you to read it carefully and
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 19, 2015 the Arlington-R Building Size 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This
More informationConstruction Manual. 1. Delivery Day
1. Delivery Day By now you should have the construction site for your new log home prepared for delivery. Your logs will be coming on a large flatbed semi trailer truck that will require you to plan ahead
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 19, 2015 the Arlington-R Building Size 12' x 24' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More informationPROJECT INSTRUCTIONS Roofing
PROJECT INSTRUCTIONS Roofing This handout outlines some basic regulations contained within the 2015 Minnesota State Building Code, as well as other good building practices. However, this handout is not
More informationSLATE & SHINGLE INSTALLATION
EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend
More informationTapersawn Shake Installation Instructions
Smart-Shingle TM System Tapersawn Shake Installation Instructions INSTALLATION GUIDE MARKS Shake-Strip 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 13, 2017 the North Dakota with pocket doors Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 Building Size 12'x12'
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 12, 2017 the Arlington Building Size 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted.
More informationUL Construction No. 254
UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 13, 2017 the North Dakota with pocket doors 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual
More informationIRONWOOD SHAKE & FLASHING SPECIFICATIONS
3 1-51 3-3/4 1 IRONWOOD SHAKE & FLASHING SPECIFICATIONS 6 1-13- 1-1-1/4 2-1.5 Drip Edge 2.5 Drip Edge 2-7/8 1-1-1/4 3/4 1 2-1 IRONWOOD SHAKE Overall Length 51 Length of Coverage 48 Width of Coverage 1
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised June 14, 2017 the Belmont-R Building Size 12' x 24' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive - Greenville, PA 16125 This manual is copyrighted.
More information