SUBMITTAL TRANSMITTAL

Size: px
Start display at page:

Download "SUBMITTAL TRANSMITTAL"

Transcription

1 SUBMITTAL TRANSMITTAL GENERAL CONTRACTORS 835 GIL HARBIN INDUSTRIAL BLVD. VALDOSTA, GA (229) Fax (229) DATE June 1, 2010 JOB NO TO: BES Incorporated 2712 Bull Street Beaufort, SC P ATTENTION RE Mr. Robert Beach Enclave Force Protection Access Control Point Contract W9128F-09-C-0051 Ft. Gillem, Georgia Submittal Number SD-05 Description Cold Formed Metal Calculations See Form 4025 Attached COPY TO File SIGNED If enclosures are not as noted, kindly notify us at once.

2 ClarkWestern material certification - code approvals and performance standards: ClarkWestern s products meet or exceed these applicable performance standards. Structural framing standards Interior drywall framing with ProSTUD Drywall Framing System AISI North American Specification for the Design of Cold-Formed Steel Structural Members, 2001 with 2004 supplement ASTM C955 ASTM C1007 Installation Load-bearing steel framing ASTM A1003 Material specification for steel sheet requirements Protective coating standards ASTM A924 ASTM A653 ASTM A463 ASTM A591 ASTM A792 ASTM A875 Metallic coated hot-dip process Zinc coated hot-dip process Aluminum-coated hot-dip process Zinc-coated, light coating mass applications 55% aluminum-zinc alloy-coated hot-dip process Zinc-5% aluminum alloy-coated hot-dip process Additional code approvals SSMA (Steel Stud Manufacturers Association) ICC-ES ER-4943P ClarkWestern Building Systems is a member of the Steel Stud Manufacturer s Association (SSMA). ClarkWestern Building Systems has prepared this literature with the utmost diligence and care for accuracy and conformance to standards. ClarkWestern Building Systems reserves the right to modify or change any information contained in this literature without notification. AISI North American Specification for the Design of Cold-Formed Steel Structural Members, 2001 with 2004 supplement ASTM C653 Coating specification ASTM A1003 Material specification ASTM C645 ASTM E119 ASTM E72 ASTM E90 Non-structural steel framing members Fire tests Strength tests Airborne sound transmission UL Underwriters Laboratories Testing Standard UL 263 Fire Tests of Building Construction/Materials Over 40 UL designs for ProSTUD See UL file number R26034 for additional information. Fire designs include U419, V450 & V438. Additional code approvals IBC International Building Code IAPMO ES Pending ICC-ES Pending **UL and UL Design are service marks of Underwriters Laboratories, Inc. ClarkWestern intends this information to be accurate, informative and helpful as a selection guide for choosing ClarkWestern Building System products. However, this information is only to be used for guidance and is not intended to replace the design, drawings, specifications and decisions of a professional architect or engineer. Independent product testing and certification Sound ratings: Western Elecro - Acoustic Laboratory Fire testing: Underwriters Laboratories Inc. Structural testing: (STAR) Structural Testing and Research Inc. Structural analysis: CTLGroup Metal lath & accessories ASTM C847 ASTM C841 Metal lath Installation of interior lathing & furring ASTM C1063 Installation of lathing & furring ASTM A653 Zinc coated hot-dip process ASTM C1047 Accessories standards control joints ASTM A924 Metallic-coated hot-dip process UUB790A APB type 1, grade D, style 2 CE ML/SFA-920 Furring (metal) lathing and plastering Guide specs for metal lathing & furring ClarkWestern Building Systems or its affiliates shall not be responsible for incidental or consequential damages, directly or indirectly sustained, nor for loss caused by application of our products for other than their intended uses. Our liability is limited to replacement of defective products. Claims shall be deemed waived unless they are made to us in writing within thirty (30) days of the date a problem was or reasonably should have been discovered. Green benefits and recycled content: LEED Credit MR 2 Construction Waste Management ClarkWestern products are manufactured from cold-formed steel. Steel is 100% recyclable, which helps divert debris from the waste stream. The contribution to LEED must be calculated by the contractor based on weight or volume. LEED Credit MR 4 Recycled Content ClarkWestern s steel products have a minimum of 25.5% post-consumer recycled content, and 6.8% pre-consumer. If you wish to report a higher number for your project or seek Credit MR 5 regional materials, please contact Tech Support at or visit USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. ClarkWestern Building Systems, Inc. plant locations: CALIFORNIA - Riverside Phone: CALIFORNIA - Woodland Phone: CONNECTICUT - Bristol Phone: FLORIDA - Dade City Phone: GEORGIA - Pendergrass Phone: ILLINOIS - Rochelle Phone: MARYLAND - Baltimore Phone: OHIO - Middletown Phone: TEXAS - Dallas Phone: ClarkWestern Design Services. A full spectrum of solutions. CW DESIGN: EAST - Roswell, GA Toll-Free Phone: Local Phone: Toll-Free Fax: Local Fax: CW DESIGN: NORTHEAST - Portland, ME Toll-Free Phone: Toll-Free Fax: CW DESIGN: WEST - Riverside, CA Toll-Free Phone: Toll-Free Fax: TECHNICAL SUPPORT: Phone: CW-FullLine 03/10 ClarkWestern Building Systems, Inc. The technical content of this literature is effective 03/05/10 and supersedes all previous information Centre Pointe Dr. Ste. 210 West Chester, OH Phone: Fax: clarkwestern.com

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

SUBMITTAL SHEET. Project Submittals by

SUBMITTAL SHEET. Project Submittals by Galvanized Tie Wire and Hanger Wire Submittal of Product Performance SUBMITTAL SHEET Project Submittals by GRABBER CONSTRUCTION PRODUCTS, INC. Submittal Date: Contract Number: Project Name: Section Number:

More information

Submittal Sheet. Product: Item# Description Unit Pack

Submittal Sheet. Product: Item# Description Unit Pack Submittal Sheet Submittal Sheet #0309412 Bugle Head Screws (212) Product: Item# Description Unit Pack C368 6 x 1-1/4-in, Bugle Head, Fine Thread,, Phosphate, Collated 1,000 1268YZ 10 x 3-1/2-in, Bugle

More information

Letter of Transmittal/Submittal

Letter of Transmittal/Submittal Letter of Transmittal/Submittal FROM: TO: Baker Concrete Construction 1904 Jasper Street DATE JOB NUMBER 09/23/10 Aurora, CO 80011 9921 303.367.8111 ATTENTION Nick Dewald 937.536.9000 RE: Bruce Herman

More information

TRANSMITTAL. Project: Moody AFB CDC Date: Comm. No.: To: Slone Associates, Inc. Fax 835 Gil Harbin Industrial Blvd.

TRANSMITTAL. Project: Moody AFB CDC Date: Comm. No.: To: Slone Associates, Inc. Fax 835 Gil Harbin Industrial Blvd. TRANSMITTAL Project: Moody AFB CDC Date: 01.11.10 Comm. No.: 09036 To: Slone Associates, Inc. Fax 835 Gil Harbin Industrial Blvd. US Mail Valdosta, GA 31601 Messenger Attn. Santiago Iturralde - 229.244.6709

More information

1.1 RELATED DOCUMENTS

1.1 RELATED DOCUMENTS SECTION 050505 -BEVEL RAIL ENDS PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 Specification Sections

More information

SECTION BULLET- RESISTANT DOORS

SECTION BULLET- RESISTANT DOORS 1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and

More information

METAL LATH PLASTERING ACCESSORIES

METAL LATH PLASTERING ACCESSORIES METAL LATH PLASTERING ACCESSORIES ESR-1623 www.cemcosteel.com TABLE OF CONTENTS FOR METAL LATH 1. Metal Lath a. Expanded Metal Lath and "D"......2 b. Self Furring Dimpled Metal Lath and "D"...... 2 c.

More information

What is stronger than concrete?

What is stronger than concrete? USG Performance Flooring Solutions What is stronger than concrete? USG LEVELROCK BRAND & USG DUROCK BRAND MYTH BROCHURE Award-winning Allentown Homes (Colorado Springs, CO) great room featuring USG Durock

More information

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-27 05 28.36 40 (August 2011) ----------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Elco Construction Products 1301 Kerr Drive Decorah, IA fax: Technical Manual 2010 HangerMate anchors were designed to speed installation of fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. They can also be used to install strut channels,

More information

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3528 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

USG BORAL HIGHLANDS CEILING SYSTEM Technical Manual (Installation Guide)

USG BORAL HIGHLANDS CEILING SYSTEM Technical Manual (Installation Guide) USG BORAL HIGHLANS CEILING SYSTEM Technical Manual (Installation Guide) The USG Boral Highlands Ceiling System provides customised ceiling visual effects with multiple perforation patterns and panel height

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 28.36 40 (May 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Translucents Canopies. Design and Installation Guide October, 2017

Translucents Canopies. Design and Installation Guide October, 2017 Translucents Canopies Design and Installation Guide October, 2017 Design and Installation Guide Translucents Canopies from USG feature stand-alone decorative elements that can be independently suspended

More information

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3870 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 05 00

More information

835 Gil Harbin Industrial Blvd Valdosta, GA 31601

835 Gil Harbin Industrial Blvd Valdosta, GA 31601 QUALITY CONTROL PLAN NAVFAC SE PUBLIC WORKS MAYPORT FEAD MAYPORT 1966 BONHOMME RICHARD STREET MAYPORT NAVAL STATION FL 32228-0073 N69450-08-D-1781/0004 835 Gil Harbin Industrial Blvd Valdosta, GA 31601

More information

Regal Series Recessed Flatwalls

Regal Series Recessed Flatwalls Regal Series Recessed Flatwalls General Specifications The Amico Regal Series Recessed Flatwall shall be manufactured by Amico Corporation, in accordance with job specific shop drawings and documents.

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 06 1053 - MISCELLANEOUS ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Division 01 Specification

More information

USG Ceiling Solutions USG PERFORATIONS METAL CEILING SYSTEMS SELECTION GUIDE

USG Ceiling Solutions USG PERFORATIONS METAL CEILING SYSTEMS SELECTION GUIDE USG Ceiling Solutions USG PERFORATIONS METAL CEILING SYSTEMS SELECTION GUIDE PRESENTING THE COMPLETE LINE OF STANDARD PERFORATION PATTERNS OFFERED BY USG. USG LIBRETTO GRIDLESS METAL SYSTEM USG CELEBRATION

More information

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. PS 061 SEVEN SPRINGS WASTEWATER TREATMENT FACILITY IMPROVEMENTS PASCO COUNTY,

More information

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE 1.0 GENERAL 1.1 Scope 1.1.1 The work shall consist of supply and installing chain link fence, including braces and gates, as shown on the plans and specifications at the locations designated by the Engineer.

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Originally Issued: 08/28/2015 Revised: 08/26/2016 Valid Through: 08/31/2017

Originally Issued: 08/28/2015 Revised: 08/26/2016 Valid Through: 08/31/2017 EVALUATION SUBJECT: STRUCTALATH NO. 17 SFCR II, NO. 17 III SFCR, NO. 17 SFCR TWIN TRACK AND NO. 17 SFCR TWIN TRACK 2.5, STRUCTA MEGA LATH, V-TRUSS WALLS AND CEILINGS LATH, V-TRUSS WALLS AND CEILINGS LATH

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 279 Reissued 08/2018 This report is subject to renewal 08/2020. DIVISION: 0 00 00 CONCRETE

More information

SIM. Mass Loaded Vinyl

SIM. Mass Loaded Vinyl Mass Loaded Vinyl SIM Soundproofing INSTALLATION Manual When building sound isolated walls, floors and ceilings, we want to introduce significant non-resonant mass. MLV is an excellent source for this

More information

American National Standard. For Wet Process Porcelain Insulators Indoor Apparatus Type ANSI/NEMA C (R2002, R2012)

American National Standard. For Wet Process Porcelain Insulators Indoor Apparatus Type ANSI/NEMA C (R2002, R2012) ANSI/NEMA C29.10-1989 (R2002, R2012) American National Standard For Wet Process Porcelain Insulators Indoor Apparatus Type Secretariat: National Electrical Manufacturers Association Approved: August 2012

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-87 (2) 99-043 www.icc-es.org ESR-3332 Reissued 09/207 This report is subject to renewal 09/208. DIVISION: 0 00 00 METALS

More information

Manufacturing Facilities City of Industry, CA Denver, CO Ft. Worth, TX Pittsburg, CA PRO-X HEADER. LEED v3 for Building and Design Construction

Manufacturing Facilities City of Industry, CA Denver, CO Ft. Worth, TX Pittsburg, CA PRO-X HEADER. LEED v3 for Building and Design Construction Cororate Headquarters 91746 Product Descrition Basic Use is a light gauge steel header that rovides horizontal and vertical load suort. This re-engineered metal framing comonent is designed as a 1- or

More information

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019 SUNMODO CORPORATION 14800 NE 65 th Street Vancouver, WA 98682 SUNMODO EZ ROOF MOUNT L-FOOT KITS FOR SHINGLE ROOFS CSI Section: 06 25 23 Wood, Plastic, and Composite Fastenings 07 71 00-Roof Specialties

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI SELF-DRILLING AND SELF-PIERCING SCREWS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI SELF-DRILLING AND SELF-PIERCING SCREWS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2196 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 05 00

More information

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 4185 Issued 06/2018 This report is subject to renewal 06/2019. SECTION: 05 05 23

More information

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 051200 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Product Evaluation Report

Product Evaluation Report Product Evaluation Report PER0601 Page 1 of 6 Initial Listing September, 06 This Document Published By: ReApproved April, 08 Listed Product VersaPin Gripshank Pneumatic Fastener Listed For Aerosmith Fastening

More information

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 53 00.00 40 (November 2015) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 53 00.00 40 (November 2008) UFGS-26 53 00 (August 2008)

More information

Grate-Lock Safety Grating - Design Load Table of Contents

Grate-Lock Safety Grating - Design Load Table of Contents Safety - Design Load Table of Contents Safe Loading Tables (6", 9", & 12" Widths) 11 2" Channel Height... 90-91 21 2" Channel Height... 92-93 3" Channel Height... 94-95 4" Channel Height... 96-97 Accessories

More information

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1408 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 05 00

More information

Classic Beauty of Handsplit Wood Shake

Classic Beauty of Handsplit Wood Shake Ageless Beauty Classic Beauty of Handsplit Wood Shake DECRA Shake XD offers the classic beauty and architectural detail of a thick, rustic, handsplit wood shake combined with the superior performance and

More information

3M Scotchlok Copper/ Aluminum Compression Lugs, Series

3M Scotchlok Copper/ Aluminum Compression Lugs, Series Copper/ Aluminum Compression s, 40000 Series Data Sheet January 2014 Description Agency Approvals and Self Certifications Copper/Aluminum Compression s 40000 Series are made of high conductivity aluminum

More information

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A SECTION 061050 - MISCELLANEOUS CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Letter of Transmittal

Letter of Transmittal 3710 QUINCY AVENUE OGDEN, UT 84403-1934 Ph : (801)627-1414 Letter of Transmittal To: GEN ARCHITECTS, INC. 11001 SW RIVERSIDE DRIVE PORTLAND, OR 97219 Ph: (503)243-7183 Fax: (503)243-7193 Subject: Submittal

More information

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply

More information

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA Approved: PC Reso No. 430 (05) September 12, 2005 Amended: PC Reso No. 583 (08) March 12, 2008 Palm Square Shopping Center Page 1 PALM SQUARE SHOPPING CENTER

More information

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION HOLLOW METAL DOORS AND FRAMES PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 08 11 13 HOLLOW METAL DOORS AND A. Non-fire-rated hollow metal doors and frames. B. Hollow metal frames for wood doors. C. Fire-rated hollow metal doors and

More information

*Revised September 1, 2003

*Revised September 1, 2003 LEGACY REPORT ER-580* Reissued January, 00 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 560 Workman Mill Road, Whittier, California 9060 # (56) 699-054 Regional Office # 900 Montclair

More information

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

LEGACY REPORT.  (800) (562) A Subsidiary of the International Code Council. *Revised September 2003 ICC-ES Evaluation Report ER-580* Reissued January 00 www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council Legacy report on the 997 Uniform Building Code DIVISION: 05

More information

USG Structural Solutions USG STRUCTURAL PANEL CONCRETE SUBFLOOR REPAIR MANUAL. usg.com

USG Structural Solutions USG STRUCTURAL PANEL CONCRETE SUBFLOOR REPAIR MANUAL. usg.com USG Structural Solutions USG STRUCTURAL PANEL CONCRETE SUBFLOOR REPAIR MANUAL usg.com TABLE OF CONTENTS USG STRUCTURAL PANEL CONCRETE SUBFLOOR... 5 Hole Patch Repair... 5 1. Patch Repair Limitation...

More information

DURATION. Shingles with Patented and SureNail Technologies. TruDefinition. Estate Gray

DURATION. Shingles with Patented and SureNail Technologies. TruDefinition. Estate Gray TruDefinition DURATION Shingles with Patented and SureNail Technologies Estate Gray TruDefinition DURATION Shingles with Patented and SureNail Technologies Bold contrast. Deep dimension. TruDefinition.

More information

ODOT ITB Group 4 Item 33 Qty. 1

ODOT ITB Group 4 Item 33 Qty. 1 ODOT ITB 180-17 Group 4 Item 33 Qty. 1 ODOT ITB 180-17 Group 4 Item 34 Qty. 1 ODOT ITB 180-17 Group 4 Item 35 Qty. 1 ODOT ITB 180-17 Group 4 Item 36 Qty. 1 STRUCTURAL BOLTS NUCOR FASTENER TECHNICAL

More information

Specialty Fastening Systems Solutions for the Construction Industry

Specialty Fastening Systems Solutions for the Construction Industry Specialty Fastening Systems Solutions for the Construction Industry BI-METAL SCREWS Drywall / Denseglass SELF DRILLING SCREWS IN STAINLESS STEEL SUS304 Steel Framing Exterior Sheathing Plank / Panel Sidings

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3564 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General CEILING SYSTEMS Between us, ideas become reality WOODWORKS Installation Instructions Linear Solid Panels 1. General 1.1 Product Description WoodWorks Linear features a solid wood ceiling system in 1' x

More information

3M Scotchlok Insulated Electrical Spring Connector B (Blue)

3M Scotchlok Insulated Electrical Spring Connector B (Blue) 3M Scotchlok Insulated Electrical Spring Connector B (Blue) Data Sheet November 2008 Application Use 3M Scotchlok Insulated Electrical Spring Connector B (Blue) to electrically connect two or more conductor

More information

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts. SECTION 58 PRECAST CONCRETE BOX CULVERT 58.1 DESCRIPTION A. General This work consists of furnishing and installing Pre-cast Concrete Box Culverts. B. Related Work Section 51 Section 52 Section 53 Section

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON MILLENNIUM DECORATIVE METAL COLUMN COVERS DIVISION 05 7500 or DIVISION 09 2000 Note To Specifier: Column Covers are a finished, decorative product and should be installed

More information

Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1

Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1 Designation: A 787 05 Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing This standard is issued under the fixed designation A 787; the number immediately

More information

A. Extent of structural precast concrete work is shown on drawings and in schedules.

A. Extent of structural precast concrete work is shown on drawings and in schedules. SECTION 03 41 00 - STRUCTURAL PRECAST CONCRETE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification

More information

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company. Government Recognized Export House OHSAS 800:200 ISO 400:2004 PED Approved Company. Phone : +9 22 44 (2 Lines) Fax : +9 22 289 4 Email : export@reliablepipes.com domestic@reliablepipes.com Designation:

More information

Ageless Beauty. Imagine. a lifetime of beauty with the strength of steel

Ageless Beauty. Imagine. a lifetime of beauty with the strength of steel Ageless Beauty Imagine a lifetime of beauty with the strength of steel Original You deserve the best, the original, DECRA As the original stone coated steel roofing system, the DECRA product line represents

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Installation

More information

4. Metal roof jacks at penetrations and attachments

4. Metal roof jacks at penetrations and attachments - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SECTION 07 61 00 METAL SHINGLE ROOFING - - - - - - - - - - -

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2451:1998 Australian/New Zealand Standard Bolts, screws and nuts with British Standard Whitworth threads (rationalized series) AS/NZS 2451:1998 This Joint Australian/New Zealand Standard was prepared

More information

St. Monica Food Pantry

St. Monica Food Pantry St. Monica Food Pantry 26 5113-1 ELECTRICAL WORK DIVISION 26 SECTION 265113 INTERIOR LIGHTING FIXTURES PART 1. GENERAL 1.1 WORK INCLUDES A. Extent, location, and details of interior lighting fixture work

More information

PROJECT TITLE PROJECT NO: CONTRACT TITLE UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PROJECT TITLE PROJECT NO: CONTRACT TITLE UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA If project is not administered in PRISM, coordinate use of Exhibit 6 submittal schedule with this section. SECTION 01 33 23 SHOP DRAWINGS, PRODUCT DATA AND SAMPLES PART 1 - GENERAL 1.1 REQUIREMENTS INCLUDED

More information

Architectural Door Accessories. Markar Continuous Hinges

Architectural Door Accessories. Markar Continuous Hinges Architectural Door Accessories Why Continuous Hinges? Hinge failure most commonly begins when doors are opened beyond stop device limits. The resulting kickback shock to the hinges can surpass 1000 lbs.

More information

SUBMITTAL REVIEW Steel Reinforcement - Slab and Masonry Shop Drawings GCAN. Notes: 1. See comments on submittal.

SUBMITTAL REVIEW Steel Reinforcement - Slab and Masonry Shop Drawings GCAN. Notes: 1. See comments on submittal. SUBMITTAL REVIEW Submittal: No. 010.00 Spec Section: 03 3000 2.3 Steel Reinforcement Shop Drawings - Slab and Masonry Reviewed By: Laura Landon, Comma-Q Architecture Date: June 13, 2012 Project: BPS Belgrade

More information

January 7, 1997 COATED PRINTING PAPER, GS-10 1 GS-10 SECOND EDITION JANUARY 7, This standard has been superseded by Edition 2.

January 7, 1997 COATED PRINTING PAPER, GS-10 1 GS-10 SECOND EDITION JANUARY 7, This standard has been superseded by Edition 2. January 7, 1997 COATED PRINTING PAPER, GS-10 1 GS-10 GREEN SEAL STANDARD FOR COATED PRINTING PAPER SECOND EDITION JANUARY 7, 1997 This standard has been superseded by Edition 2.1, July 12, 2013 Green Seal,

More information

SECTION TRAFFIC SIGNAGE

SECTION TRAFFIC SIGNAGE SECTION 10 14 53 TRAFFIC SIGNAGE PART 1 - GENERAL 1.01 SECTION INCLUDES A. Furnishing and installing roadside traffic signage. B. Providing additional traffic signs as required in Sections 01 55 28 Controlling

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Versai Evolution of Versatile Fencing

Versai Evolution of Versatile Fencing Versai Evolution of Versatile Fencing About Versai Ornamental Fencing Versai Ornamental Fencing Versai Ornamental Fencing by Fortress is the next generation in ornamental fencing. It offers a solution

More information

Corrosion of Roofing Fastener Systems

Corrosion of Roofing Fastener Systems Corrosion of Roofing Fastener Systems Interim Report March 2, 2016 Kurtis Gurley, PhD, Forrest Masters, PhD, PE Associate Professor of Civil Engineering Engineering School of Sustainable Infrastructure

More information

Steel wire for general fencing purposes

Steel wire for general fencing purposes BRITISH STANDARD BS 4102:1998 ICS 77.140.65 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Specification for Steel wire for general fencing purposes Committees responsible for this

More information

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO. 2012-16A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST 2014 CHAIN LINK FENCE SPECIFICATIONS Chain link fence,

More information

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION test TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Cold-Formed Steel Engineers Institute Washington, DC www.cfsei.org 866-465-4732 SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 51 13 (May 2011) ------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 51 13 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1475 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 07 00

More information

A. It is preferred that all submittals to be submitted electronically in PDF format.

A. It is preferred that all submittals to be submitted electronically in PDF format. June 20 2013, Rev 00 10 2800 Toilet, Bath, and Laundry Accessories PART 1. GENERAL 1.01 This Section includes: A. Toilet room accessories: 1.02 Submittals 1. Grab bars 2. Metal framed mirrors 3. Sanitary

More information

HEADLINE BUILDING MATERIALS

HEADLINE BUILDING MATERIALS EADLINE BUILDING MATERIALS eb: www.hbm.ae l Email: commercial@hbm.ae eavy ex Structural Bolts ASTM A 325M Metric Series Dimensions P.O. Box 37366, Dubai, UAE l Tel: +971 4 3475675 l Fax: +971 4 347 5485

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

Hilti, Inc. November Dallas Parkway, Suite 1000 Plano, Texas Toll Free Website Guide Specification

Hilti, Inc. November Dallas Parkway, Suite 1000 Plano, Texas Toll Free Website  Guide Specification Hilti, Inc. November 2015 7250 Dallas Parkway, Suite 1000 Plano, Texas 75024 Toll Free 800-879-8000 Website www.us.hilti.com Guide Specification Specifier Notes: This guide specification is written in

More information

SUBMITTAL REVIEW Underground Natural Gas Piping Data Sheets GCAN. Notes: 1. See engineer s comments. Submittal: No. 016.

SUBMITTAL REVIEW Underground Natural Gas Piping Data Sheets GCAN. Notes: 1. See engineer s comments. Submittal: No. 016. SUBMITTAL REVIEW Submittal: No. 016.00 Spec Section: 3 113 Underground Natural Gas Piping Reviewed By: Laura Landon, Comma-Q Architecture Date: June 1, 01 Project: BPS Belgrade Elementary School Location:

More information

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5. 1.0 Scope 2.0 References 3.0 Definitions 4.0 Submission and Design Requirements 5.0 Materials 5.1 General 5.2 Marking 6.0 Equipment 7.0 Production 7.1 Steel Octagonal Poles 7.2 Base Plate 7.3 Top Cap 7.4

More information

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out. Woven Steel Wire Fence Type-47 Under the state specification 710.02 for fencing, ASTM A 116 is called out. Go to the steel and fencing certification manual for more information about the basic properties

More information

PART MATERIALS. Section Fencing Materials. Description

PART MATERIALS. Section Fencing Materials. Description PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain

More information

Product Catalog 2012 Bollards Cleats Cleat Seat Bench Trash Receptacle Bollard

Product Catalog 2012 Bollards Cleats Cleat Seat Bench Trash Receptacle Bollard J.C. MacElroy Company, Inc. Product Catalog 2012 Bollards Cleats Cleat Seat Bench Trash Receptacle Bollard 91 Ethel Road West Piscataway, NJ 08854 Phone: (732) 572-7100 Fax: (732) 572-7112 info@macelroy.com

More information

SECTION METAL FABRICATIONS

SECTION METAL FABRICATIONS SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM

More information

DURATION SHINGLES. with SureNail Technology. TruDefinition Duration Shingles are a component of the Owens Corning Total Protection Roofing System.

DURATION SHINGLES. with SureNail Technology. TruDefinition Duration Shingles are a component of the Owens Corning Total Protection Roofing System. TruDefinition DURATION SHINGLES with SureNail Technology TruDefinition Duration Shingles are a component of the Owens Corning Total Protection Roofing System. ^ Estate Gray TruDefinition DURATION SHINGLES

More information

Design and Construction Standards SECTION ATHLETIC LOCKERS

Design and Construction Standards SECTION ATHLETIC LOCKERS SECTION 10505 ATHLETIC LOCKERS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The provisions of the General Conditions, Supplementary Conditions, and the Sections included under Division 1, General Requirements,

More information

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT [March 25, 2015] Malarkey recently received our new, updated ICC ES Evaluation Report (ESR 3150) which includes the additions of Windsor shingles and all

More information

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,

More information

Solar Reflective Shingles

Solar Reflective Shingles Solar Reflective Shingles Mesquite WWW.MALARKEYROOFING.COM Distributed From: (See chart inside for distribution) Ecoasis Premium features Cool Roofing Granules from 3M that reflect solar rays, which may

More information

Grounding and Utility Enclosure

Grounding and Utility Enclosure Grounding and Utility Enclosure UE-1P UE-1P-INS Revision 1 DX Engineering 2006 P.O. Box 1491 Akron, OH 44309-1491 Phone: (800) 777-0703 Tech Support and International: (330) 572-3200 Fax: (330) 572-3279

More information

SECTION REFERENCE STANDARDS

SECTION REFERENCE STANDARDS SECTION 01 42 00 S PART 1 GENERAL 1.01 REQUIREMENTS INCLUDED A. Applicability of Reference Standards. B. Provision of Reference Standards at site. C. Acronyms used in Contract Documents for Reference Standards.

More information

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1360 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

DIVISION 6 WOOD AND PLASTICS

DIVISION 6 WOOD AND PLASTICS DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 34 59 (August 2008) Change 1-11/12 --------------------------- Preparing Activity: USACE Superseding UFGS-08 34 59 (April 2006) UFGS-08 34 53.00 40 (June 2006) UNIFIED

More information

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section 02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,

More information

Section Meetings Section Material and Equipment. None Required

Section Meetings Section Material and Equipment. None Required January 2000 Page 1 of 8 PART 1 GENERAL 1.01 OTHER CONTRACT DOCUMENTS 1.02 DESCRIPTION OF WORK 1.03 RELATED WORK PART 2 PRODUCTS The General Conditions of the Contract, General Requirements and Supplemental

More information

REPORT HOLDER: SENCO BRANDS INC IVY POINTE BOULEVARD CINCINNATI, OHIO EVALUATION SUBJECT: SENCO SELF-DRILLING AND SELF-PIERCING SCREWS

REPORT HOLDER: SENCO BRANDS INC IVY POINTE BOULEVARD CINCINNATI, OHIO EVALUATION SUBJECT: SENCO SELF-DRILLING AND SELF-PIERCING SCREWS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3558 Reissued 06/2017 This report is subject to renewal 06/2019. DIVISION: 05 00

More information