FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.
|
|
- Karin Robbins
- 5 years ago
- Views:
Transcription
1 FUEL GAS PIPING SECTION PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior fuel gas piping, other than service piping from the street gas main. C. Related work in other section: See SECTION 15050, BASIC MECHANICAL MATERIALS AND METHODS and SECTION PLUMBING. 1.2 QUALITY ASSURANCE A. Installers qualification: See SECTION B. Submittals: 1. Manufacturer s Data: a. Pipe and Fittings b. Pressure Regulator c. Gas Equipment Connectors d. Valves e. Automatic Earthquake Shutoff Valve, including certification f. Warning Type C. Requirements of Regulatory Agencies 1. California Code of Regulations (CCR) Title 24 Part 4 California Mechanical Code, Appendix B, chapter 22, Fuel Gas Piping. Title 24 Part 5 California Plumbing code, Chapter 12, Fuel Gas Piping Title 24 Part 12 Standard No : California Standard for Earthquake Actuated Automatic Gas Shutoff System.
2 D. Reference Standards: The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only. 1. American National Standards Institute (ANSI) Publications: B1.1 Unified Inch Screw Threads (UN and UNR Thread Form) B Pipe Threads, General Purpose (Inch) B16.3 Malleable Iron Threaded Fittings, class 150 and 300 B16.5 Pipe Flanges and Flanged Fittings B16.9 Factory-Made Wrought Steel Butt welding Fittings. B16.11 Forged Steel Fittings, Socket-Welding B16.33 Manually Operated Metallic Gas Valves for use in Gas Piping System up to 125 psig. B16.39 Malleable Iron Threaded Pipe Unions, Class 150, 250, and 300. B B Square and Hex bolts and Screws Inch Series Including Hex Cap Screws and Lag Screws Square and Hex Nuts Z21.69 Connectors for Movable Gas Appliances. Z21.70 Earthquake Actuated Automatic Gas Shutoff Systems 2. American Society of Testing and Materials (ASTM) Publications: A53 A120 Pipe, Steel, Black and Hot-Dipped Zinc-Coated (Galvanized ) Welded and Seamless, for Ordinary Uses Pipe, Steel, Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless, for Ordinary Uses PART 2 PRODUCTS
3 2.1 GENERAL A. Materials and equipment shall conform with the requirements of CCR Title 24, Part 5, Chapter 12, and with the following. 2.2 PIPING See Section SHUT-OFF VALVES A. ABOVEGROUND: Valves shall be as follows with sizes as indicated: 1. Size Larger than 2 Inches: casts-iron body plug valve per ANSI B 16.38, nonlubricated, wedge-mechanism or tapered lift plug flanged ends. 2. Sizes 2 Inches and Smaller: Bronze body plug valve per ANSI B16.33, straightway, taper plug, regular pattern with a port opening at least equal to the internal pipe area or round port full bore pattern, non-lubricated, Teflon packing, flat or square head stem with lever operator, 125 psig WOG rating, threaded ends. 2.4 PRESSURE REGULATOR A. Spring-loaded diaphragm pressure regulator, (psig to inches water reduction) pressure operating range as required for the pressure reduction indicated, volume capacity not less than indicated, and threaded ends for sizes 3 inches and smaller, otherwise flanged. Maxitrol or equal. Size, capacity, type model number and accessories as scheduled or shown. 2.5 EARTHQUAKE AUTOMATIC GAS SHUT-OFF VALVE A. ANSI Z21.70 fabricated and UL listed or AGA (American Glass Association) listed or IAPMO (International Association of Plumbing and Mechanical Officials) listed. The valve may be either pendulum or ball type. B. Approved by the state architect and conforming to CCR, T24, Pt12, STD GAS EQUIPMENT CONNECTORS A. Flexible Connectors: ANSI Z B. Quick Disconnect Couplings: ANSI Z21.41.
4 C. Semi-rigid Tubing and Fittings: ANSI Z PART 3 EXECUTION 3.1 INSTALLATION A. General: Install gas piping, appliances, and equipment, in accordance with Title 24, Part 5 California Plumbing Code, and Part 4, Appendix B where applicable. B. Excavating and Backfilling in accordance with SECTION 15050, BASIC MECHANICAL MATERIALS AND METHODS. C. Piping: Cut pipe accurately to actual dimensions and assemble to preclude residual stress. Terminate each vertical supply pipe to burner or appliance with tee, nipple and cap to form a sediment trap. To supply multiple items of gas-burning equipment, provide manifold with inlet connections at both ends. D. Clean inside of pip and fittings before installation. Blow lines clear using 80 to 100 psig clean dry compressed air. Steel lines shall be rapped sharply along entire pipe length before blowing clear. Cap or plug pipe ends to maintain cleanliness throughout installation. E. Valves: 1. Install valves approximately at locations indicated. Orient stems vertically with operators on top or horizontally. Provide support for valves to resist operating torque to Plastic pipes. 2. Pressure Regulator: Provide plug cock ahead of regulator. Install regulator inside building and extend a full-size vent line from relief outlet on regulator to a suitable point outside of building. On outlet side of regulator, provide a union and a 3/8-inch gauge tap with plug. 3. Stop Valve and Shut-Off Valve: Provide stop valve on service branch at connection to main and shut-off valve on riser outside of building. F. Final Connections: 1. Make final connections to all equipment and appliances using rigid pipe and fittings. 2. Caution: Make final connections gas-tight, using minimal torque. 3.2 FIELD INSPECTION AND TEST:
5 A. In addition to the inspections required by Code the following inspections, procedures and tests shall be carried out by the Contractor. B. System Purging: After pressure tests, and before testing a gas contaminated line, purge line with nitrogen at junction with main line to remove all air or gas. Clear completed line by attaching a test pilot fixture at capped stub-in line at building location and let gas flow until test pilot ignites. CAUTION Failure to purge may result in an explosion within the line. END OF SECTION
A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements.
SPEC-3017 1/8 1.0 PURPOSE This specification describes the minimum requirements for the installation of breathing air distribution systems (indoor and outdoor) up to the connection to the breathing air
More informationThis specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.
SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to
More informationSECTION BASIC MATERIALS AND METHODS
SECTION 15050 BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and Fittings. 1.02 RELATED SECTIONS A. Basic Mechanical Requirements: Section 15010. B. Supports, Anchors, and Seals:
More informationThis specification describes the minimum requirements for piping systems for the following service:
201/11/2 1/9 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Underground Service Water Note: This specification does not apply to piping
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125
More information.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.
Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems
More informationThis specification describes the minimum requirements for piping systems for the following service:
201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)
More informationSECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING
SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationNote: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings.
1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Liquid and High Pressure Gaseous Dry Sulphur Dioxide (Less than 100 ppm of water)
More informationAllentown, PA - Plant Expansion Steel Pipe Spec. No. 671-S40 December 31, 2015
Steel DIVISION 15: MECHANICAL SECTION 15061: STEEL PIPE 1.0 GENERAL All materials shall be of high quality and as per the following specifications. 2.0 PRODUCTS 2.1 Specification CS-1 Service = (CA, VAC)
More informationMueller Gas Products. Mueller H17800 Curb Stop Tee No Blo Curb Stop Tee Weld x Weld 1440 PSI
Mueller Gas Products Distributed by: Mountain States Pipe and Supply Colorado Springs, Colorado 80903 1 800 777 7173 Mueller H17800 Curb Stop Tee No Blo Curb Stop Tee Weld x Weld 1440 PSI MUELLER NO-BLO
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING
SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationSteel Couplings. Product Specifications Welded steel couplings both galvanized and black in diameters from 1/8 up to 4
Merchant Couplings Steel Couplings Merchant Couplings Product Specifications Welded steel couplings both galvanized and black in diameters from 1/8 up to 4 Technical Specifications Standards: Product complies
More informationSection COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.
PART 1 GENERAL 1.01 SUMMARY Section 15155 This Section covers couplings and coupling adapters for ductile iron and steel pipe. 1.02 MEASUREMENT AND PAYMENT A. No separate payment for Work performed under
More informationA. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.
SECTION 22 05 16 LOOPS FOR PLUMBING PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION FUEL OIL SYSTEM (PLUMBING)
SECTION 15484 FUEL OIL SYSTEM (PLUMBING) PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02221 - Excavating, Backfilling, and Compaction for Utilities. 2. 03300 - Cast-In-Place Concrete. 3. 15410 -
More information5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves
MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping
More informationGeneral Information. Ball Curb Valve
General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)
More informationReliance SG800 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationFITTINGS & GAUGES 20,000 PSI
PRESSURE GAUGE Features 4" high visibility face with laminated safety glass dial cover Accurate within +/- 0.5% of full scale range Stainless steel case and internals Heavy-duty movement Glycerine-filled
More informationQUALITY ASSURANCE SPECIFICATION
Page 1 of 8 QAS: 2.02 QUALITY ASSURANCE SPECIFICATION REVISION: 0 DATE: 08/29/14 MATERIAL PURCHASING Code Material Purchase Specification for Pipe, Valves, Fitting, and Flanges PAGE 1 OF 8 1.0 Purpose
More informationSECTION TRAFFIC SIGNAGE
SECTION 10 14 53 TRAFFIC SIGNAGE PART 1 - GENERAL 1.01 SECTION INCLUDES A. Furnishing and installing roadside traffic signage. B. Providing additional traffic signs as required in Sections 01 55 28 Controlling
More informationEngineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard
Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More information5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.
2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc
More informationSymphony II Adaptable Table System
Symphony II Adaptable Table System 1.00 General 1.01 Conditions 1.02 Scope of work 1. This section covers all materials, equipment, tools and labor for the supply and installation of the laboratory Symphony
More informationB34 Series Regulator Commercial and Industrial Regulator
B34 Series Regulator Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34 is particularly
More informationSECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section
02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,
More informationHYDRONIC PIPING
SECTION 23 21 13 HYDRONIC PIPING PART 1 GENERAL 1.01 SECTION INCLUDES A. Hydronic system requirements. B. Heating water piping, above grade. C. Chilled water piping, above grade. D. Condenser water piping,
More informationMATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.
Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.
More informationPage 1 of 12 Second Revision No. 5-NFPA 12-2014 [ Section No. 2.3.4 ] 2.3.4 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C 700, West Conshohocken, PA 19428-2959. ASTM A53, Standard
More informationSECTION BULLET- RESISTANT DOORS
1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and
More informationFisher 667 Diaphragm Actuators Size 80 and 100
Instruction Manual 667 Size 80 and 100 Actuators Fisher 667 Diaphragm Actuators Size 80 and 100 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Maximum Pressure Limitations...
More informationHydraulic Adapters STEEL PIPE ADAPTERS NPTF DRY SEAL PIPE ASSEMBLY INSTRUCTIONS. Steel Pipe Adapters. Steel Pipe Adapters. Hydraulic.
CONFORMANCE SAE J54 for hex nipples, expanders, elbows, tees and crosses SAE J54, J50 and J5 for bushing and plugs. Temperature Range -65 0 F to +400 0 F MATERIALS - SAE L4 carbon steel plated zinc with
More informationCaution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation
Genie Probe Regulator (GPR)/ Genie Probe (GP2)/ Genie Probe for Composite Sampler (CSA)/ And (Model H) Installation and Operation Instructions Caution: Not designed for external fire. Prior to use in a
More informationFord Water Meter Couplings & Accessories
Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas
More informationThe MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.
MUELLER SMALL DRILLING MACHINES 2.1 Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines are available in hand
More informationFitting C.O. Adapter
ABS-DWV Fittings ABS/DWV Service Weight Pipe Schedule 30 Single step solvent cementing procedures no primer required. Excellent solvent cementing characteristics. Black. 84/Ctn. x h Hub Sanitary 0321612
More informationSECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 05 12 00 - STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. This Section includes plumbing fixtures and related components.
SECTION 224200 PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationTENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018
SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationSAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2
SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT Addendum No. 2 The following shall modify the Contract Documents. The work shall be accomplished in accordance with such modifications.
More informationInternational Organization for Standardization. American National Standards Institute
DFTG1329 Standards are published documents that set up rules, specifications and protocols designed to ensure consistency, compatibility and reliability of products, materials and services. Standards are
More informationSECTION COMMON WORK RESULTS FOR HVAC
SECTION 23 05 00 COMMON WORK RESULTS FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball Valve. 2. Hangers and Supports. 3. Identification Tags and Sleeves. 1.2 INCLUDED SECTIONS A. Section
More informationCV Control Valves Installation and Operation Manual
CV00 - Control Valves Installation and Operation Manual Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation of the Armstrong CV00 Control Valve. Selection
More informationANSI ORIFICE FLANGES METAL-KOREA
METAL-KOREA ANSI ORIFICE FLANGES ORIFICE FLANGES are widely used in conjunction with orifice meters for measuring the rate of flow of liquids and gases. They are basically the same as standard welding
More informationThe MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.
MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines
More informationI-VICFLEX.VS1. Victaulic VicFlex Style VS1 Dry Sprinkler WARNING WARNING TECHNICAL DATA BEND CHARACTERISTICS INSTALLATION INSTRUCTIONS SIDEWALL
INSTALLATION INSTRUCTIONS I-VICFLEX.VS1 Victaulic VicFlex Style VS1 Dry Sprinkler SIDEWALL Y Read and understand all instructions before attempting to install any Victaulic VicFlex Style VS1 Dry Sprinklers.
More informationDIVISION 6 WOOD AND PLASTICS
DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.
More informationRiser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8
Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18 Manual 40100X35-8 3 2 4 Access covers with bolts supplied with Interceptor 1 5 14 6 11 15 Sampling Port/Cleanout cap supplied with Interceptor 12
More informationSECTION MANHOLES
SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard
More information1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series
SECTION 31 66 13 HELICAL PILES AND HELICAL ANCHORS PART 1 - GENERAL 1.1 DESCRIPTION A. This work pertains to furnishing and installing Helical Piles and Bracket Assemblies shown in the Contract in accordance
More informationSECTION DOMESTIC WATER AND SANITARY DRAINAGE PIPING PART 1 GENERAL
15140.1 SECTION 15140 DOMESTIC WATER AND SANITARY DRAINAGE PIPING PART 1 GENERAL 1.1 SECTION INCLUDES A. Furnish and install sanitary drainage and vent piping systems, and domestic water piping, including
More informationSECTION METAL FABRICATIONS
SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM
More informationPRESTON HEALTH SERVICES ARCHITECT S NO. 2700
SECTION 23 3113 - LOW PRESSURE DUCTWORK PART 1 - GENERAL 1.1 SCOPE OF WORK: A. The work required under this section includes all work necessary for a complete installation of ductwork and accessories.
More informationExcavating, Backfilling, and Compaction for Utilities Piping (Plumbing).
SECTION 15047 - IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Identification including necessary accessories indicated on Construction Documents and specified in this section or as required
More informationAUDAS. Tel: Fax: No.259 Baichi north Rd.Haiyan.Zhejiang.
Standard State SECTION A : SCREW THREAD Basic elements of screw thread design ANSI/ASME B1.7M Nomenclature.Definitions and letter symbols for screw thread ASME B1.1 Unified inch screw thread ( UN and UNF
More informationMEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C
MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of
More information1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"
More informationThe Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8
September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers
More informationSECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY
SECTION 26 05 36 CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY PART 1 -GENERAL 1.1 SUMMARY A. Section includes cable tray. 1.2 REFERENCES A. ASTM A 123 Standard Specification for Zinc (Hot-Dip Galvanized)
More informationFIRE PROTECTION PRODUCTS
FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,
More informationInstallation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602
596 597 Installation Tools Pipe Cutters for steel and cast iron pipes 598 Pipe Cutters / Pipe Deburring Reamer for stainless steel pipes 600 Pipe Cutters / Pipe Deburring Reamer / Calibrating Tool for
More informationMUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2
operating Instructions manual MUELLER GAS TAble of contents PAGE DH-5 Drilling Machine For use on 1 1 /2 & 2 Line Stopper Fittings General Information 2 Installing and Stopping-off 1 1 /2 and 2 Line Stopper
More informationMUELLER E-5TM. and D-5TM. Drilling Machines. Reliable Connections. E-5 General Information 2. D-5 General Information 3. Operating Instructions 4-5
operation Instructions manual MUELLER E-5TM and D-5TM TAble of contents PAGE E-5 General Information 2 Drilling Machines D-5 General Information 3 Operating Instructions 4-5 E-5 Parts 6 D-5 Parts 7! WARNING:
More informationPiping & Equipment Identification
Piping & Equipment Identification Part 1 General 1.01 Description of Work A. Work in this section includes: Identification materials, including necessary accessories indicated on Contract Documents and
More informationPART MATERIALS. Section Fencing Materials. Description
PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain
More informationApplication for design registration
Avis au lecteur sur l accessibilité : Ce document est conforme au standard du gouvernement du Québec SGQRI 008-02 afin d être accessible à toute personne handicapée ou non. Toutes les notices entre accolades
More informationSECTION CABLE TRAYS
SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More information00238 R4 BODY, BOLT ON TORQUE TUBE PRODUCT LINE: 916/18 DATE: 12/4/06
0 0 SH CAP SCREW, /-0 NC X / G PLAIN 00 NUT, NYLOCK, /-0 NC ZINC 00 HH CAP SCREW, /- NC X G ZINC 0 O-RING, -N0, -/ OD X / SECTION 00 WHEEL DRIVE MOTOR WITH KEY 0 00 GEAR, WHEEL DRIVE MOTOR 0 WASHER, /
More informationVersai Evolution of Versatile Fencing
Versai Evolution of Versatile Fencing About Versai Ornamental Fencing Versai Ornamental Fencing Versai Ornamental Fencing by Fortress is the next generation in ornamental fencing. It offers a solution
More informationMiniature Steam Pty Ltd (Incorporating Live Steam Supplies)
Miniature Steam Pty Ltd (Incorporating Live Steam Supplies) Materials List 28 May 2013 The attached listings outline products we offer and their retail prices as at the above date. We reserve the right
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationNAVSEA STANDARD ITEM T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods
NAVSEA STANDARD ITEM ITEM NO: 009-48 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Pressure Seal Bonnet Valve; repair (shop) 2. REFERENCES: 2.1 S9086-CJ-STM-010/CH-075, Fasteners 2.2. T9074-AS-GIB-010/271,
More informationKhathij Industrial Fasteners
Dear Sir/Madam, Khathij Industrial Fasteners This is Saqubar Sadique representing 'KHATHIJ INDUSTRIAL FASTENERS' from Chennai, India. We 'Khathij industrial fasteners' like to introduce us as a Stockist
More informationUL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.
UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator
More informationSection Heavy Duty Slide Gates Tender No. [ ] Page 1
Tender No. [ ] Page 1 1.0 GENERAL 1.1 REFERENCES.1 Provide heavy duty slide gates in accordance with the following standards (latest revision) except where specified otherwise..2 American Society for Testing
More informationRepair Manual 12 PL PILOT
Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without
More informationA. Deviation from this standard must be approved by the Project Architect.
September 2012, rev. 00 26 5600 Exterior Lighting PART 1. GENERAL 1.01 Related Documents A. Deviation from this standard must be approved by the Project Architect. B. Drawings and general provisions of
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PRESSURE GAUGES, Section 15130
PART 1 GENERAL 1.01 SUMMARY Section 15130 PRESSURE GAUGES, This Section includes the furnishing and subsequent installation of pressure gauges and pressure level transmitters as shown on Plans and specified
More informationPIPING NOMENCLATURE. Header Branch connection Valve Flange Expansion joint Expansion loop Pipe support Reducer Elbow
PIPING COMPONENTS Piping components are mechanical elements suitable for joining or assembly into pressure-tight fluid containing piping systems. Components include pipe, tubing, fittings, flanges, gaskets,
More informationSECTION CUSTOM FABRICATED EQUIPMENT
SECTION 11401 CUSTOM FABRICATED EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 05500 - Metal Fabrications. 2. 10100 - Chalkboards, Markerboards, Tackboards, and Bulletin Board Cabinets.
More informationGeberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio
Geberit Duofix Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Masse Geberit Duofix Element für Wand-WC, cm, mit Sigma Unterputzspülkasten cm 9¾" (500) 4¾" (0)
More informationYour Global Sales Partner
Your Global Sales Partner www.techlineint.com THE TECHLINE COMMITMENT As a leader in global sourcing since 1982, we are dedicated to placing the world s manufacturing capabilities within the grasp of our
More information11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014
74 480 330 90 72 180 150 60 90 18 11- OD at Transition Point 36 184 74 Microcosmic Elevation 14 1 Moto Ohtake I. GENERAL NOTES: A. SCULPTURE DESIGN CRITERIA 1. CALIFORNIA BUILDING CODE (CBC, 2010 EDITION)
More informationSECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)
PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 03 15 00 CONCRETE ANCHORING Display hidden notes to specifier. (Don't know how? Click Here) A. General purpose mechanical anchors for horizontal and vertical
More informationDrilling & Tapping Wide selection from a single source. Durable designs.
Drilling & Tapping Wide selection from a single source. Durable designs. Type No. of Models Nom. Size (in.) Page Hole Cutting Model HC300 3 Up to 3" 6.2 Model HC450 3 Up to 4 3 4" 6.3 Hole Saws 51 Up to
More informationRELINER INSIDE DROP SYSTEM SPECIFICATIONS
1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme
More informationMounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves
Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves NOTE: These instructions apply only to 60 series ball valves with bodies containing external mounting nibs. External
More informationHow to Identify a PBM VALVE SERIES
How to Identify a PBM VALVE SERIES Series 0 (SP, DP, MP) 1. If it is a manual valve, the handle generally would be made of a cast iron or cast bronze. 2. If it is a manual valve, the stem at the very top
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 33 13 (May 2009) Change 2-11/12 --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 051200 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationAutomated Tiki Torch Installation Instructions
Automated Tiki Torch Installation Instructions Automated Tiki Torch with Poles (Exploded View) 14 Automated Tiki Head 6 8 Tiki Pole (Powder Coated Aluminum or Faux Bamboo Pole) 12 Base Pole (Powder Coated
More informationFisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87
Instruction Manual 667 Actuator (Size 30/30i - 76/76i and 87) Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationSECTION CHAIN LINK FENCING
SECTION 32 31 13 CHAIN LINK FENCING PART 1 - GENERAL 1.01 SECTION INCLUDES A. The Work specified in this Section consists of furnishing and installing permanent chain link fences and gates in accordance
More informationReliance SG777 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.SG777 10/16/2016 Reliance SG777 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationMBC /602(L) MBC /602(L) MBC /602(L)
GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Two normally closed automatic shutoff valves and servo regulator in one
More informationCollins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY
PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply
More informationNAVSEA STANDARD ITEM
NAVSEA STANDARD ITEM FY-19 DATE: 01 OCT 2017 CATEGORY: I 1. SCOPE: 1.1 Title: Threaded Fastener Requirements; accomplish 2. REFERENCES: 2.1 Standard Items 2.2 S9086-CJ-STM-010/075, Fasteners 3. REQUIREMENTS:
More information