LUCAS MUNOZ SURVEY NO. 86 ABSTRACT NO. 488, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS.

Size: px
Start display at page:

Download "LUCAS MUNOZ SURVEY NO. 86 ABSTRACT NO. 488, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS."

Transcription

1 PALM VALLEY LOCATION MAP PARADISE TRACE SOL HALLIE PL VALLEY RD R.O.W. SQ.FT. D.R. FIR SIR G,E,T,CA D.P.R. O.P.R. N.T.S. 410 RAY ELLISON BLVD LEGEND SET 1/2" IRON ROD W/ CAP STAMPED "VICKREY PROP. COR." (UNLESS OTHERWISE NOTED) SIGN (AS NOTED) RIGHT-OF-WAY SQUARE FEET NOT TO SCALE DR 410 STORM WATER MANHOLE ELM VALLEY RAY ELLISON DR FOUND 1/2" IRON ROD W/ CAP STAMPED "VICKREY PROP. COR." (UNLESS OTHERWISE NOTED) SITE BLVD DEED RECORD OF BEXAR COUNTY, TEXAS WALNUT OFFICIAL PUBLIC RECORD OF REAL PROPERTY OF BEXAR COUNTY, TEXAS VALLEY GAS, ELECTRIC, TELEPHONE AND CABLE TELEVISION DR DEED AND PLAT RECORDS OF BEXAR COUNTY, TEXAS GN1 GN2 GN3 10M PARCEL ACRE DRAINAGE EASEMENT GENERAL NOTES FIR ACRE TRACT DEED REFERENCE: VOL , PG. 908, O.P.R. OWNER: SCC REALTY COMPANY, LTD. L8 POINT OF BEGINNING FIR PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE OWNER: SCC REALTY COMPANY, LTD. BURIED PIPELINE MARKER L7 STORM DRAIN STRUCTURE FIR INLET STRUCTURE N22 14'00"W ' 10M PARCEL ACRE DRAINAGE EASEMENT C1 STORM DRAIN STRUCTURE 10L GAS EASEMENT FIR 10G 10H 10I 10J 10K 10L 10M SCHEDULE B EXCEPTIONS CURVE C1 C2 C3 LENGTH ' ' ' RADIUS ' ' ' CURVE TABLE DELTA TANGENT 25 38'46" ' 18 12'14" ' 58 23'04" ' CHORD BEARING S50 31'02"E S46 47'47"E N51 28'10"W CHORD ' ' ' AS-SURVEYED DESCRIPTION Being a acre (181,065 square feet) tract of land out of the Lucas Muñoz Survey No. 86, Abstract No. 488, and the Maria F. Rodriguez Survey No. 4, Abstract No. 16, New City Block 15228, situated in the City of San Antonio, Bexar County, Texas, said acre tract being comprised of a portion of a acre tract conveyed from Ray Ellison Self Storage, LLC to S&K Development Company, Inc. by Warranty Deed recorded in Volume 15042, Page 904, Official Public Records of Real Property (O.P.R.) of Bexar County, Texas (all records cited herein are recorded in Bexar County, Texas), a acre tract conveyed from James M. Schneider to S&K Development Company, Inc. by Special Warranty Deed recorded in Volume 17563, Page 214, O.P.R. and a portion of Old Dwyer Road, a closed and vacated right-of-way by Ordinance , said acre tract being more particularly described as follows, with all bearing being referenced to North American Datum of 1983, Texas Coordinate System, South Central Zone: BEGINNING at a found ½ iron rod with cap stamped VICKREY PROP. COR. at a point of curvature to the right, on the south right-of-way (ROW) line of Ray Ellison Blvd. (ROW varies in width), said point being the intersection of the centerline of said closed and vacated Old Dwyer Road and the south right-of-way line of said Ray Ellison Blvd., said corner being the northwest corner of land conveyed to S&K Development Company, Inc. by said ordinance and being a corner of land conveyed to SCC Realty Company, Ltd. by said ordinance, for the northwest corner of the herein described tract; THENCE along the southwest right-of-way line of said Ray Ellison Blvd., the following two (2) calls: 1.)along said curve to the right, along the northeast line of said closed and vacated Old Dwyer Road and said acre tract, an arc length of feet, with a radius of feet, a central angle of 25 38'46, and a chord bearing and distance of S50 31'02 E, feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. at a tangent point, for a corner of the herein described tract, and 2.)S37 43'27 E, along the northeast line of said acre tract, a distance of feet to a found ½ iron rod with yellow cap stamped BIG SKY RPLS 5418 at the most northerly corner of a acre tract conveyed from S&K Development Company, Inc. to City of San Antonio by Warranty Deed recorded in Volume 17675, Page 1362, O.P.R., for a corner of the herein described tract; THENCE departing said southwest right-of-way line of Ray Ellison Blvd., into and across said acre tract and along the northwest and southwest lines of said acre tract, the following three (3) calls: 1.)S52 16'33 W, a distance of feet to a found ½ iron with yellow cap stamped BIG SKY RPLS 5418 at the most westerly corner of said acre tract, for an interior corner of the herein described tract, 2.)S37 43'27 E, a distance of feet to a found ½ iron rod with yellow cap stamped BIG SKY RPLS 5418 at a point of curvature to the left, for a corner of the herein described tract, and 3.)along said curve to the left, an arc length of feet, with a radius of 1, feet, a central angle of 18 12'14, and a chord bearing and distance of S46 47'47 E, feet to a set ½ iron rod with cap stamped VICKREY PROP. COR. on a northwest line of the remaining portion of Lot 2, Block 146, New City Block 15228, Freedom Hills Apartment, an addition to the City of San Antonio, according to plat thereof recorded in Volume 9694, Page 180, Deed and Plat Records, for the most easterly corner of the herein described tract; THENCE S34 19'37 W, departing said southwest line of acre tract, into and across said acre tract, closed and vacated Old Dwyer road and acre tract and along said northwest line of remaining portion of Lot 2, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. on the southwest line of said acre tract, same point also being an interior corner for said Lot 2, for the most southerly corner of the herein described tract; CIVIL ENVIRONMENTAL SURVEY DESCRIPTION NO. DATE REVISIONS Country Parkway San Antonio, TX Telephone: (210) TBPLS Firm Registration No: FIR-RED CAP STAMPED "RPLS 4540" L6 L5 FIR FOUND 3/8" IRON ROD IN CONCRETE MONUMENT REMAINING PORTION OF LOT 2, BLOCK 146, N.C.B FREEDOM HILLS APARTMENT (VOL. 9694, PG. 180, D.P.R.) DEED REFERENCE: VOL , PG. 1297, O.P.R. OWNER: JAMES M. SCHNEIDER C3 S37 43'27"E ' PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE OWNER: S&K DEVELOPMENT COMPANY, INC. UTILITY RESERVATION ORDINANCE FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" ACRE TRACT (181,065 SQ. FT.) OUT OF A ACRE TRACT CONVEYED FROM RAY ELLISON SELF STORAGE, LLC. TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 904, O.P.R.) A ACRE TRACT CONVEYED FROM JAMES M. SCHNEIDER TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 214, O.P.R.) AND A PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE L2 L1 FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" BURIED PIPELINE MARKER ACRE TRACT JAMES M. SCHNEIDER TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 214, O.P.R.) C2 APPROXIMATE LOCATION OF SURVEY LINE EDGE OF PAVEMENT MARIA F. RODRIGUEZ SURVEY NO. 4 ABSTRACT NO. 16, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS. PARCEL 19369A ACRE TRACT S&K DEVELOPMENT COMPANY, INC. TO CITY OF SAN ANTONIO (VOL , PG. 1362, O.P.R.) INLET STRUCTURE L3 10L SIR DEPRESSION BURIED PIPELINE MARKER THENCE along the common line of said Lot 2 and acre tract, the following three (3) calls: 1.)N80 38'43 W, a distance of feet to a found 3/8 iron rod in concrete monument at a point of curvature to the right, for a corner of the herein described tract, 2.)along said curve to the right, an arc length of feet, with a radius if feet, a central angle of 58 23'04, and a chord bearing and distance of N51 28'10 W, feet to a found 3/8 iron rod in concrete monument at a point of tangency, for a corner of the herein described tract, and 3.)N22 14'00 W, a distance of feet to a found ½ iron rod with red cap stamped RPLS 4540 at the most northerly corner of said Lot 2, same point also being the southeast corner of a acre tract conveyed to SCC Realty Company, Ltd. by Deed recorded in 17338, Page 908, O.P.R., same point also being the southwest corner of said land conveyed to SCC Realty Company, Ltd. by said ordinance, for a corner of the herein described tract; THENCE N80 32'32 E, along the south line of said land owned by SCC Realty Company, Ltd. by said ordinance, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. at the southeast corner of said land owned by SCC Realty Company, Ltd., same point also being the most northerly corner of said acre tract and lying on the centerline of closed and vacated Old Dwyer Road, for an interior corner of the herein described tract; THENCE continuing along said centerline of closed and vacated Old Dwyer Road, along the east line of said land owned by SCC Realty Company, Ltd. by said ordinance and along the west line of land owned by S&K Development Company, Inc. by said ordinance, the following three (3) calls: 1.)N22 14'00 W, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR., for a corner of the herein described tract, 2.) N27 57'40 W, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR., for a corner of the herein described tract, and N40 40'12 W, a distance of feet returning to the POINT OF BEGINNING and containing acres (181,065 square feet) of land. CAT. 1A, COND. II LAND TITLE SURVEY LAND TITLE SURVEY OF A ACRE (181,065 SQUARE FEET) TRACT OF LAND OUT OF THE LUCAS MUÑOZ SURVEY NO. 86, ABSTRACT NO. 488, AND THE MARIA F. RODRIGUEZ SURVEY NO. 4, ABSTRACT NO. 16, NEW CITY BLOCK 15228, SITUATED IN THE CITY OF SAN ANTONIO, BEXAR COUNTY, TEXAS. 6/7/ :49:52 PM \ ranguiano R:\ \Survey\dwg\SH_SURVEY01-1.dwg LUCAS MUNOZ SURVEY NO. 86 ABSTRACT NO. 488, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS. FOUND 3/8" IRON ROD IN CONCRETE MONUMENT L4 FIR PRELIMINARY, THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWED OR RELIED UPON AS A FINAL SURVEY DOCUMENT. PREPARED FOR: DATE S&K DEVELOPMENT COMPANY, INC c PROJ NO. DATE: SCALE 1" = 50' OF 1 1 DRAWN BY: R.M.A. APPROVED BY: S.H. FIELD CREW: J.M.

2

3 FH-2 CURB BLDG-4 12,092 SF ANE FIRE LANE R GUTTE SITE PLAN & CURB BLDG-5 18,131 SF TANK 1 GAL. 18 0K FFE=76 9 CONC 33' DIA. PUMP HOUSE WATER WELL FH-1 FIRE L BLDG-3 18,358 SF N TIO N E DET OND P EX 2 FH SEPTIC FIELD 2772 SF BLDG-2 TWO-STORY 14,195 SF OFFICE T IDEN RES = E FF File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: 7-SITE Plotted: 3/28/2018 3:45:17 PM Plotted by: Albert Rubio UTTER FIRE IO ENT T E AD COS &G CURB LANE ND N PO R LN TER 8" WT & GUT EX 1 FH 7 OF 10

4 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: EX-CONDITIONS Plotted: 9/20/ :15:59 AM Plotted by: Albert Rubio COSA DETENTION POND SCALE: 1":40' 0' 50' 100' 8 OF 16 EXISTING CONDITIONS

5 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: EROSION Plotted: 9/20/ :17:29 AM Plotted by: Albert Rubio LOC LOC LOC LOC LOC LOC LOC AREA (SEE DETAIL) WASHOUT & LOC CONSTRUCTION LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF LOC LOC LOC LOC LOC SF SF SF SF SF SF SF COSA DETENTION POND SCALE: 1":40' 0' 100' 200' LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SPOILS AREA CONCRETE SF SF SF SF SF SF LOC LOC SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF STABILIZED ENTRANCE LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC SF SF LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOCLOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF LOC LOC LOC LOC 8 OF 16 STORM WATER POLLUTION PREVENTION PLAN

6 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA-EX OFFSITE Plotted: 9/20/ :18:42 AM Plotted by: Albert Rubio OS AC DA AC COSA DETENTION POND 0' 100' 200' SCALE: 1":40' NE CORNER EX. CULVERTS NE CORNER EX. DETENTION POND DA AC DA AC OS AC OS AC LEGEND DRAINAGE AREAS TIME AND CONCENTRATION DRAINAGE AREA FLOW ARROW SE CORNER EX. 4X4 AREA INLET 8 OF 16 DRAINAGE AREA MAP-EXISTING CONDITIONS

7 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA Plotted: 9/20/ :19:38 AM Plotted by: Albert Rubio S=0.25% OS AC 0.44 AC FFE=767.5 HOUSE PUMP WELL WATER DA-3 S=5.0% 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND HP SCALE: 1":40' 0' 100' 200' LEGEND DRAINAGE AREAS TIME AND CONCENTRATION DRAINAGE AREA FLOW ARROW NE CORNER EX. CULVERTS NE CORNER EX. DETENTION POND FDC FH S=5.5% 14,195 SF TWO-STORY SEE EXISTING DRIANAGE MAP FOR OFFSITE TOPOGRAPHY BLDG-2 DA AC HP S=0.6% 18,131 SF BLDG-5 12,092 SF BLDG-4 18,358 SF BLDG-3 DA AC OS AC OS AC BP AC FH S=0.8% S=7.8% S=0.7% HP BP AC S=9% T/W= T/W=771.5 RAMP S=7:1 7' W ACCESS T/W= POND DETENTION T/W= BP AC T/W=770.5 SE CORNER EX. 4X4 AREA INLET 8 OF 16 DRAINAGE AREA MAP-DEVELOPED CONDITIONS

8 EXISTING CONDITIONS DEVELOPED CONDITIONS CONCRETE REINFORCEMENT DETAIL (NOT TO SCALE) CONC. SPLASH PAD 3' W X 4" H REINF.CONC. SLAB ON 2" SAND CUSHION W/#3 OC 2' CURB (TYP.) EACH WAY 3' CURB-CUT (TYP) #5 18" OC EACH WAY 8" CONC. POND WALL W/#4 18" OC 8" CONC. POND WALL EACH WAY W/#4 18" OC EACH WAY 2' L X 8"H CONC. FOOTING 3-#5 CONT. HORIZ. BARS #5 #5 18" OC 18" OC EACH WAY EACH WAY CONC. SPLASH PAD 3' W X 4" H REINF.CONC. SLAB ON 2" SAND CUSHION W/#3 OC EACH WAY 2' L X 8"H CONC. FOOTING 3-#5 CONT. HORIZ. BARS DRAINAGE CALCULATIONS File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA CALCS Plotted: 9/20/ :20:03 AM Plotted by: Albert Rubio NOTE: REINFORCEMENT SHALL ACCURATELY BE PLACED AT SLAB MID DEPTH OR WALL CENTER AND HELD FIRMLY IN PLACE BY MEANS OF BARS SUPPORTS OF ADEQUATE STRENGTH AND NUMBER THAT WILL PREVENT DISPLACEMENT AND KEEP STEEL AT ITS PROPER POSITION DURING THE PLACEMENT OF THE CONCRETE. IN NO INSTANCE SHALL THE STEEL BE PLACED DIRECTLY ON THE SUBGRADE OR SAND CUSHION LAYER. 12 OF 18

9 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: SITE Plotted: 9/20/ :20:29 AM Plotted by: Albert Rubio BLDG-4 12,092 SF FFE=767.5 HOUSE PUMP 12" WTR LN 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND EASEMENT WELL WATER SCALE: 1":40' 0' 100' 200' FDC 8" WTR LN FH-1 14,195 SF TWO-STORY BLDG-2 8" WTR LN 18,131 SF BLDG-5 18,358 SF BLDG-3 FH-2 DRAINAGE POND DETENTION 8 OF 16 SITE PLAN

10 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DIMENSION Plotted: 9/20/ :21:05 AM Plotted by: Albert Rubio 12,092 SF FFE=767.5 HOUSE BLDG-4 PUMP 12" WTR LN 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND WELL WATER SCALE: 1":40' 0' 100' 200' FDC 8" WTR LN FH-1 14,195 SF TWO-STORY BLDG-2 8" WTR LN 18,131 SF BLDG-5 18,358 SF BLDG-3 FH-2 POND DETENTION 8 OF 16 DIMENSION CONTROL PLAN

11 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: GRADING 1 Plotted: 9/20/ :21:37 AM Plotted by: Albert Rubio S=0.25% 775 S=7.8% 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K TANK 1 TANK 2 COSA DETENTION POND SCALE: 1":20' 0' 50' 100' WATER WELL 12" WTR LN RESIDENT 765 FFE=767.5 HOUSE PUMP OFFICE S=5.0% HP FDC 8" WTR LN FH-1 S=5.5% 14,195 SF TWO-STORY BLDG HP S=0.6% 8" WTR LN HP 774 MAH LINE 8 OF 16 GRADING PLAN ONE

12 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: GRADING 2 Plotted: 9/20/ :21:59 AM Plotted by: Albert Rubio MAH LINE 8" WTR LN HP S=0.6% HP ,131 SF BLDG-5 18,358 SF BLDG-3 FH ,092 SF BLDG S=0.8% S=0.7% SCALE: 1":20' 0' 50' 100' S=9% T/W= T/W=771.5 RAMP S=7:1 7' W ACCESS DETENTION POND T/W= T/W= T/W= OF 16 GRADING PLAN TWO

13 10' 20' 7' CONC CHAN POND FL(IN)= ' 100 YR WSE= ' 20' T/WALL= ' T/WALL= :1 0' 0' 25 YR WSE= X3 CONC PAD POND FL(OUT)=766 4' W ROCK AREA=766.7 :1 7 = S S=0.5% 100 YR WSE= YR WSE= YR WSE=768.3 FL= ' CONC PAD=766.5 FINISH GRADE 5 YR WSE=768.3 PROPERTY LINE PROPERTY LINE T/WALL=770.5 T/WALL=771.5 S= DETENTION POND SECTION "A-A" SCALE: 1" = 10' DETENTION POND SECTION "B-B" SCALE: 1" = 10' DETENTION POND SECTION "C-C" SCALE: 1" = 10' 7' W ACCESS RAMP S=7:1 DETENTION POND T/WALL=770.5 T/WALL= YR WSE= YR WSE= YR WSE= " ORIFICE FL=766 FL= FINISH GRADE 3X3 CONC PAD POND FL(OUT)=766 B T/W=770.5 TOP WALL= T/ W =7 C.5 B 71 DETENTION POND (OUTLET) 7.25" DIA. ORIFICE=766.0 DETENTION POND PLAN 766 A 5' CONC PAD W/ENERGY DISSIPATORS =766 30' ' 30' DETENTION POND OUTFALL (NOT TO SCALE) DETENTION DETENTION POND (OUTLET) 1.25' L WEIR= ' 10' PROPERTY LINE 10' T/ W = ' 0' 76 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: POND DETENTION Plotted: 9/20/ :22:25 AM Plotted by: Albert Rubio A T/W=770.5 C SCALE: 1" = 10' 770.5T/W=771.5 POND OUTFALL 1.25' WEIR FL= OF 18

14 HP " R PUM HO P FFE USE = " W T 1+00 BEGIN WTR LN A 1-93,000 GALS. WATER TANK No " GATE VAVLE 1-8" 22.5 BEND 25 NE 24 "R FDC FH-1 30' 60' BLDG-5 18,131 SF FH-2 CURB WTR LN A 1-514" FIRE HYDRANT 1-8"X6" TEE MJ 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 11.5 L.F. 6" D.I. PIPE CL WTR LN 1-8" BEND SCALE: 1":30' 0' 8" WTR LN 2+30 WTR LN 1+20 WTR LN A 17'X17' PUMP HOUSE 1-93,000 GALS. WATER TANK No " 45 BENDS 1-8" GATE VAVLE 1-8" GATE VAVLE BEND SEE PUMP HOUSE DETAIL WTR LN A 1-FIRE DEPT. CONNECTION 1-8"X6" TEE MJ 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 11.5 L.F. 6" D.I. PIPE CL. 350 BLDG-4 12,092 SF FIRE L A CP 770. R LN FIRE L ANE CP N BLDG-3 18,358 SF TR L HP BLDG-2 TWO-STORY 14,195 SF OFFICE WATER WELL 12" W E NT RESID FFE=7 2 TANK K 3 9. GAL 68 7 = E F F. 31 DIA CONC TANK 1 3K GAL = E FF CONC 31' DIA T/W= CESS AC 1 7' W P S=7: 8. 6 M 6 7 RA T/W = D PON N IO ENT T E AD COS FIRE CU LANE P 24" RC UTTER RB & G TER & GUT CURB & GUT TER WTR LN A 1-514" FIRE HYDRANT 1-8"X6" TEE MJ 1-8" CAP 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 10 L.F. 6" D.I. PIPE CL ' FIRE PUMP: FAIRBANKS NIJHUIS HORIZONTAL SPLIT CASE 6" F MODEL PUMP 1,500 GPM 2" WATER LINE TO APARTMENT/OFFICE FIRE SPRINKLER SYSTEM 2" WTR 1. ALL PIPE FITTINGS SHALL BE CAST IRON FLANGE TYPE WITH DUCTILE IRON PIPE WITHIN THE PUMP HOUSE. 2. ALL PIPE FITTINGS AND PIPE SHALL BE AT LEAST 1 FT ABOVE PUMP HOUSE CONCRETE FLOOR AND INSTALLED WITH PIPE SUPPORT. 3. NORMAL AND EMERGENCY LIGHTING SHALL BE PROVIDED AT THE PUMP HOUSE. 12"X2" WATER SERVICE TAP THERMOSTATICALLY ACTIVATED VENT FAN AND PASSIVE Dbl LOUVER VENT STANDARD HOSE SPIGOT ATTACHED TO EXTERIOR WALL 11.8' 12" FLG X PE PIPE 6' GARAGE DOOR FIRE DEPARTMENT NOTES: EXHAUST COLLAR THRU WALL (TYP.) 3.0' 2. THE CITY OF MANOR FIRE DEPARTMENT SHALL HAVE A RIGHT OF ENTRY ONTO PROPERTY TO INSPECT ANY PORTION OF THE FIRE PROTECTION WATER SYSTEM AS DEEMED NECESSARY IN THE CITY'S REASONABLE DETERMINATION. 3. THE TANKS, PUMPS, AND OTHER IMPORTANT ASPECTS OF FIRE PROTECTION SYSTEM SHALL BE INSPECTED QUARTERLY BY QUALIFIED PERSONNEL ASSIGNED BY HOME OWNERS ASSOCIATION. 6. FINAL INSPECTION REQUIRED BY MANOR FIRE DEPARTMENT AFTER FIRE PROTECTION SYSTEM HAS BEEN INSTALLED. 2" WTR 7. THE DIESEL TANK SHALL BE A 119 GAL CAPACITY DOUBLE WALL TANK AS RECOMMENDED BY THE AURORA PUMP SUPPLIERS. THE MINIMUM TANK SIZE REQUIRED WAS CALCULATED BASED ON 100% OF HP PLUS EXPANSION 5% AND SUMP RESERVE 5% 64 HP X 1.10 = 70.4 GAL CAPACITY REQUIRED ' 6. FIRE PUMP HOUSE SHALL BE CONSTRUCTED WITH AN AUTOMATIC SPRINKLER SYSTEM PER NFPA SEC KNOX KEY BOX SHALL BE PROVIDED AT PUMP HOUSE FOR FIRE DEPT. ACCESS.. 5. FIRE PUMP AND DIESEL MOTOR SHALL BE INSTALLED ON CONCRETE BASE PER MANUFACTURER'S INSTRUCTIONS. 1. A COMPLETE OPERATION MANUALS SHALL BE PROVIDED THAT INCLUDES PUMP CURVES, ELECTRICAL SCHEMATIC AND COMPONENTS OF THE CONTROL PANEL, AND PUMP MAINTENANCE RECOMMENDATIONS WITH REQUIRED FREQUENCIES AND WRITTEN WARRANTY FROM PUMP SUPPLIERS TO HOME OWNERS ASOCIATION AND KEPT ON FILE FOR FUTURE RERENCE. KNOX KEY BOX DIESEL ENGINE EXHAUST MUFFLER TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 7. A REPORT OF EACH INSPECTION, TEST, AND RESULTS MUST BE KEPT ON FILE AND BE READILY AVAILABLE TO THE MANOR FIRE DEPT UPON REQUEST OR AS REQUIRED BY FIRE CODE. 8. ANY OPERATIONAL DEFICIENCIES MUST BE NOTED AND INCLUDED IN THE REPORT TOGETHER WITH RECOMMENDED REMEDIATION NECESSARY TO BRING THE FIRE PROTECTION TANKS AND PUMP INTO PERMIT COMPLIANCE REGARDING SYSTEM OPERATION. FIRE PROTECTION - WATER PLAN PUMP HOUSE NOTES: 2" WTR 20' - 2" WTR PVC Sch ALARM HORN/BELL SHALL BE ACTIVATED WHEN FIRE PUMP IS ON AND SUCTION INTAKE IS DRAINING TANKS. PUMP HOUSE DETAIL (NOT TO SCALE) ALARM HORN/BELL (WEATHER PROOF TYPE) SHALL BE INSTALLED ON EXTERIOR WALL OF PUMP HOUSE AND BE ACTIVATED WHEN FIRE PUMP IS ONAND SUCTION INTAKE OPERATIONAL PASSIVE Dbl LOUVER VENT 8" WATER LINE PVC C900 ALARM LIGHT IN VAPOR PROOF FIXTURE WITH A 40-WATT FLASHING RED LIGHT SHALL BE INSTALL ON EXTERIOR WALL FOR FIRE PUMP FAILURE INDICATOR File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: WATER Plotted: 9/20/ :22:51 AM Plotted by: Albert Rubio 12" WTR TO TANKS 8 OF 16

15

16

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee) MEMORANDUM MICHAEL B. FLETCHER, P.E. COUNTY ENGINEER 327 N. Ashley Street Valdosta, GA 31601 Telephone: (229) 671-2424 Fax: (229) 245-5299 mfletcher@lowndescounty.com LOWNDES COUNTY ENGINEERING PLAN REVIEW

More information

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under

More information

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of

More information

Porter County Plan Commission

Porter County Plan Commission Plan Type: Development Plan Administrative DRC PC Primary Plan Administrative DRC PC Secondary Plat/Replat Administrative DRC PC PUD Conceptual Detailed Final Project Information Project Name: Developer

More information

Authorized Agent: City of Manassas Check List Attached: Contact: Address: Phone Number: Fax Number: Developer s Name: Phone Number:

Authorized Agent: City of Manassas Check List Attached: Contact:   Address: Phone Number: Fax Number: Developer s Name: Phone Number: CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street Room 201 Manassas, Virginia, 20110 Phone: 703-257-8278 Fax: 703-257-5831 Application Date: APPLICANT

More information

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360) CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION

More information

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.

More information

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN N/A Waiver (1) Four (4) copies of application form. (2) Fifteen (15) copies of plan (3) Subdivision/site plan application fee & professional review escrow deposit (4) Variance application fee & professional

More information

List of Figures. List of Forms

List of Figures. List of Forms City of Columbia Engineering Regulations PART 1: SUBMISSION OF PLANS Table of Contents Paragraph Description Page No. 1.1 General 1-1 1.2 Engineer s Report 1-1 1.3 Plans 1-3 1.4 Revisions to Approved Plan

More information

SECTION SITE SURVEYS

SECTION SITE SURVEYS SECTION 02 21 13 SITE SURVEYS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section to specify survey required before design

More information

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Project Name: BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Phase: Unit: # Lots: Development Type (residential, commercial, industrial, etc.) Braselton Project No.

More information

City of Massillon Site Plan Checklist

City of Massillon Site Plan Checklist City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete

More information

VICINITY MAP SCALE 1'' = 2000'

VICINITY MAP SCALE 1'' = 2000' LOCATED IN THE SOUTHWEST QUARTER OF SECTION AND THE WEST HALF OF SECTION 4, TOWNSHIP SOUTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, SHEET OF 5 E47 TOLL ROAD CASE NO. ZAX 26-4 LEGAL DESCRIPTION: A

More information

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

Residential Room Addition / Remodel Submittal Requirement Checklist

Residential Room Addition / Remodel Submittal Requirement Checklist City of Elko Building Department 1753 College Avenue Elko, Nevada 89801 (775) 777-7220 fax (775) 777-7229 Residential Room Addition / Remodel Submittal Requirement Checklist TWO COMPLETE SETS OF PROPERLY

More information

CHAPTER 11. Plan Standards

CHAPTER 11. Plan Standards CHAPTER 11 Plan Standards A. Introduction The city requires uniform public improvement plans for ease of record keeping and understanding. The following standards govern most plan submittals to the city.

More information

APPLICATION FOR SITE PREPARATION PERMIT

APPLICATION FOR SITE PREPARATION PERMIT Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision/Plat Name: Location Description/ Nearest Intersection: Acreage: APPLICATION FOR SITE PREPARATION PERMIT No.

More information

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE E-10 ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS The City of Lompoc has determined that the Engineering Division should administer and issue Encroachment

More information

Lantz-Boggio Architects 5650 DTC Parkway, Suite 220 Englewood, CO UPPER LEVEL 113' - 4"

Lantz-Boggio Architects 5650 DTC Parkway, Suite 220 Englewood, CO UPPER LEVEL 113' - 4 CASTLE PINES NORTH FILING NO. 9. LOTS,,,, TRACT B AND TRACT J A PORTION OF THE N / OF SECTION, TS, RW, SIXTH P.M.. ACRES XXXX-XXX ' - " 00 00 0 KEYNOTE LEGEND 00 00 0 0 0 0 00 0 ' - " ' - " ' - " 00' -

More information

Application for Site Plan Review

Application for Site Plan Review Application for Site Plan Review 3275 Central Blvd., Hudsonville, Michigan 49426-1450, 616.669.0200 fax 616.669.2330 It is STRONGLY recommended that any application that must go before the Planning Commission

More information

1.1 GENERAL RECORD DRAWING REQUIREMENTS

1.1 GENERAL RECORD DRAWING REQUIREMENTS Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has

More information

MAY J. Collins Engineering Associates, LLC San Jose Blvd. Jacksonville, Florida 32223

MAY J. Collins Engineering Associates, LLC San Jose Blvd. Jacksonville, Florida 32223 PROJECT LOCATION: 95 NOCATEE PARKWAY PONTE VEDRA, FL. 38 J. Collins Engineering Associates, LLC 56-3 San Jose Blvd. Jacksonville, Florida 32223 NOT TO SCALE 904-262-42 sm sm ON DRAWING WHERE SECTION OR

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing

More information

AGENDA Planning Review Committee Pinellas County Planning Department 310 Court Street, 1 st Floor Conference Room 119 April 8, :00 A.M.

AGENDA Planning Review Committee Pinellas County Planning Department 310 Court Street, 1 st Floor Conference Room 119 April 8, :00 A.M. AGENDA Planning Review Committee Pinellas County Planning Department 310 Court Street, 1 st Floor Conference Room 119 April 8, 2013 10:00 A.M. Case Summary Review: 1. CU-3-1-13 Berati # 2, LLC 2. Z/LU/CU-7-3-13

More information

PLANNING AND DEVELOPMENT

PLANNING AND DEVELOPMENT OVERVIEW Effective January 1, 1992 all applications for multi-family residential and all non-residential building permits require site plan approval before permit issuance. All new developments and existing

More information

Residential Construction Checklist Single and Two Family Construction

Residential Construction Checklist Single and Two Family Construction DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy

More information

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION:

CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION: CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION: LOG NO.: LEGEND REVIEW REVIEWED BY DATE / - Requirement satisfied 1 O Requirement not satisfied 2?

More information

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached). ACSA PLAN REVIEW CHECKLIST (Guideline Only) Revised: December 3, 2015 General (1) Proper Title (2) Vicinity map on first sheet. (3) Date and latest plan revision. (4) Standard water and sewer general plan

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST Project Name Checked By Date Designer Check List marks to be

More information

CITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST

CITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST CITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST Tract Number and Subdivision Name: Engineering Firm: Contact Person: Address: City: State: Zip: Phone No. Fax No. Assessor s Parcel Number(s) Tentative

More information

DANE COUNTY ORDINANCE AMENDMENT NO: Internal Tracking Number: RECU25846

DANE COUNTY ORDINANCE AMENDMENT NO: Internal Tracking Number: RECU25846 DANE COUNTY ORDINANCE AMENDMENT NO: 10314 Internal Tracking Number: RECU25846 Amending Section 10.03 relating to Zoning Districts in the Town of Cottage Grove. The Dane County Board of Supervisors does

More information

Grease Interceptor Design Checklist

Grease Interceptor Design Checklist CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private

More information

Item 2. September 28, 2017

Item 2. September 28, 2017 September 28, 2017 Item 2 Applicant: Georgetown Development Location: 190 N 1100 W Prepared by: Sean Conroy, Community Development Director Public Hearing: No Zone: PRD-1 Attachments: 1. Findings. 2. Project

More information

Community & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS

Community & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS Community & Economic Development Department Planning Division 14177 Frederick Street PO Box 8805 Moreno Valley, CA 92552-0805 (951) 413-3206 Fax (951) 413-3210 SECOND UNITS Completed and Signed Project

More information

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

Oil-Water Separator Design Checklist

Oil-Water Separator Design Checklist CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water

More information

3. The PAC (Permit Application Center) will notify the design professional of plan review results.

3. The PAC (Permit Application Center) will notify the design professional of plan review results. Planning and Development Dept. Infrastructure Division P.O. Box 11706, or 155 Johnston Street Rock Hill, South Carolina 29731-1706 Phone: 803-329-5515 FAX: 803-329-7228 www.cityofrockhill.com AS-BUILT

More information

APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST

APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST VI-K -1 of 8 APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST Final Submittal Major Subdivision Project Name Subdivision Number Location (Street

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable

More information

Minor Site Plan Application and Checklist Land Disturbing Activities

Minor Site Plan Application and Checklist Land Disturbing Activities Minor Site Plan Application and Checklist Land Disturbing Activities INSTRUCTIONS: Please provide the requested information below. The Development Services Department reviews each site plan submittal based

More information

Cabaniss Engineering Inc.

Cabaniss Engineering Inc. 280 North River Church 4215 Rice Mine Road NE -1529 North River Church Subdivision Plat Book 2010, Page 131 Deed Book 550 Page 761 4 18,427 sf 67.7' 5 14,367 sf 60.2' 65.0' 3 13,546 sf 35.2' 6 35' X 277.99

More information

PRELIMINARY PLAT CHECK LIST

PRELIMINARY PLAT CHECK LIST Name of Proposed Subdivision: The following items must be included with the initial submittal of a Preliminary Plat: Application, filled out completely Project Narrative Pre-application Conference Report

More information

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST YES* GENERAL SUBMISSION ITEMS Does the submission include: 1. Thirteen (13) copies of completed Application Form? 2. Thirteen (13) copies of the Preliminary

More information

Fundamentals III CHAPTER PROJECT EXERCISE

Fundamentals III CHAPTER PROJECT EXERCISE CHAPTER 4 Fundamentals III PROJECT EXERCISE This project exercise provides point-by-point instructions for setting up the drawing with layers and then creating the objects shown in Figure P4 1. FIGURE

More information

DOCUMENT MINIMUM CONSTRUCTION DRAWING REQUIREMENTS FOR PRELIMINARY REVIEW/APPROVAL 1.2. GALVESTON COUNTY CONSOLIDATED DRAINAGE DISTRICT (GCCDD)

DOCUMENT MINIMUM CONSTRUCTION DRAWING REQUIREMENTS FOR PRELIMINARY REVIEW/APPROVAL 1.2. GALVESTON COUNTY CONSOLIDATED DRAINAGE DISTRICT (GCCDD) DOCUMENT 01105 FOR PRELIMINARY REVIEW/APPROVAL PART I: SUBMITTAL 1.1 CITY OF FRIENDSWOOD (COF) A. Submit four (4) copies of drawings. B. Submit by 5:00 PM a minimum of fourteen calendar days (14 cd) prior

More information

SECTION III SUBMITTALS AND APPROVALS

SECTION III SUBMITTALS AND APPROVALS SECTION III SUBMITTALS AND APPROVALS In order to expedite the approval process of new water distribution system and sanitary sewer collection system extensions, the Hilton Head No. 1 Public Service District

More information

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS INCORPORATED VILLAGE OF ROCKVILLE CENTRE BUILDING DEPARTMENT SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS Presubmission - Prior to a formal submission, the applicant should meet in person with

More information

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements

More information

Zoning District: R-1, R-2, and R-4 Applicant: Exeter Rose Farm, LLC, 953 Islington Street #23D Portsmouth, NH 03801

Zoning District: R-1, R-2, and R-4 Applicant: Exeter Rose Farm, LLC, 953 Islington Street #23D Portsmouth, NH 03801 2220.00, Town Planner Town Planning Office, Town of Exeter 10 Front Street Exeter, NH 03833 Re: Exeter Rose Farm Subdivision Design Review Engineering Services Exeter, New Hampshire Site Information: Tax

More information

Sewer Line Extension Permit Design Checklist

Sewer Line Extension Permit Design Checklist CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line

More information

June 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA

June 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA June 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA ADDENDUM NO. 5 BID NO. Y14-792 PH IFB EAST SERVICE AREA POTABLE WATER AND RECLAIMED WATER STORAGE AND REPUMP FACILITY BID OPENING: June

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

Site Plan/Building Permit Review

Site Plan/Building Permit Review Part 6 Site Plan/Building Permit Review 1.6.01 When Site Plan Review Applies 1.6.02 Optional Pre- Application Site Plan/Building Permit Review (hereafter referred to as Site Plan Review) shall be required

More information

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION 4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of

More information

P.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint)

P.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint) P.L., CHAPTER, approved October, Assembly, No. 0 (First Reprint) 0 0 0 AN ACT concerning the approval and filing of maps and amending P.L.0, c.. BE IT ENACTED by the Senate and General Assembly of the

More information

Tooker Family Residence

Tooker Family Residence 110 25 90 E B M U D (N) POP-UP DRAIN + DRAIN ROCK BASIN DISCHARGE OF SURFACE DRAINS AND DOWNSPOUTS - SHEET FLOW ACROSS LANDSCAPE NOTE: SEE SHEET S2.0.1 FOR FOUNDATION + RAIN WATER DRAINAGE DESIGN 143.57'

More information

7000 Fifteen Mile Road Sterling Heights, Michigan

7000 Fifteen Mile Road Sterling Heights, Michigan 7000 Fifteen Mile Road Sterling Heights, Michigan Industrial Building With Excess Land and Rail Access As exclusive agents, we are pleased to offer the following property for lease: 128,648 Sq. Ft. Completely

More information

Washington County Road Engineering Plan Submittal/Review Checklist

Washington County Road Engineering Plan Submittal/Review Checklist Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should

More information

Clarifications in italics added July 2018

Clarifications in italics added July 2018 SECTION 10000 RECORD DRAWING CHECKLIST Clarifications in italics added July 2018 All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes,

More information

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September

More information

DEVELOPMENT PLAN CHECKLIST

DEVELOPMENT PLAN CHECKLIST Project Identification Information: DEVELOPMENT PLAN CHECKLIST 1.0 GENERAL 1.1 Additional information as required by specific Land Use 1.2 All sheets to include sheet number ( of ) 1.3 Seal and signature

More information

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS All plans for sanitary sewer main extensions, improvements and modifications

More information

Town of Westlake Construction Plans Review Checklist

Town of Westlake Construction Plans Review Checklist CONSTRUCTION PLANS CONTENTS All Drawings 24 x 36 Cover Sheet Final Plat Site Plan Demolition Plan Utility Plan Drainage Area Map and Calculations Paving Plan & Profile Sheets Storm Drain Plan & Profile

More information

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards. PLAN REQUIREMENTS The plans for street design shall conform to the requirements of Sections 3 and 4. The following requirements shall also be shown on the plans where applicable. Road and Storm Plans:

More information

3. DESIGN SPECIFICATIONS

3. DESIGN SPECIFICATIONS Schedule H to Bylaw 7452, Subdivision Bylaw Page 10 3. DESIGN SPECIFICATIONS 3.1 General 3.1.1 The Design Specifications apply to the design of sanitary sewers, storm drains, waterworks, roadways, and

More information

What Plans Do I Need for a Building Permit?

What Plans Do I Need for a Building Permit? What Plans Do I Need for a Building Permit? 6 CITY OF PORTLAND, OREGON - BUREAU OF DEVELOPMENT SERVICES 1900 SW 4th Avenue, Por tland, Oregon 97201 503-823-7300 www.portlandoregon.gov/bds This brochure

More information

Example Plans: Business Signs (Not For Construction)

Example Plans: Business Signs (Not For Construction) Plans: Business s Site Plan 220 10 utility easement 120 40 50 Proposed Awning Proposed Freestanding 40 79 20 Street Name Proposed Wall C L N 123 Historic Way Indianapolis, IN 46000 Basic Elements of a

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT

SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY SITE PLAN INFORMATION PACKET GENERAL INFORMATION This information packet explains how your application for a single-family site plan will

More information

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details. DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard

More information

ROUTES: 65 SECTIONS: miles in length. THE FOLLOWING ITEMS AND APPROXIMATE QUANTITIES ARE INVOLVED:

ROUTES: 65 SECTIONS: miles in length. THE FOLLOWING ITEMS AND APPROXIMATE QUANTITIES ARE INVOLVED: ARKANSAS DEPARTMENT OF TRANSPORTATION CA0801 HWY. 110 - CLINTON (WIDENING) (S) FEDERAL AID PROJECT ACNHPP-0071(31) THE PURPOSE OF THIS PROJECT IS TO WIDEN HIGHWAY 65 IN VAN BUREN COUNTY. THIS PROJECT CONSISTS

More information

KC Water Rules and Regulations For Water Main Extensions and Relocations

KC Water Rules and Regulations For Water Main Extensions and Relocations KC Water Rules and Regulations For Water Main Extensions and Relocations MAY 2017 NOTE: Changes from 2016 are highlighted in yellow and appear on Pages 5, 8, 10-11, 13, and 15. Additional changes made

More information

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL This summary is not all inclusive of the requirements set forth by the York County Planning & Development Services, York County

More information

10010 RECORD DRAWING INFORMATION

10010 RECORD DRAWING INFORMATION SECTION 10000 RECORD DRAWING CHECK LIST All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes, shall submit to the Town of Cary Engineering

More information

Essential Skills: Reading and Interpreting Maps and Plans

Essential Skills: Reading and Interpreting Maps and Plans Essential Skills: Reading and Interpreting Maps and Plans Prepared for: NEW YORK STATE PLANNING FEDERATION April 14, 2015 Prepared by: BME ASSOCIATES Peter G. Vars, P.E. Stages of Plan Review Concept /

More information

Residential Plot Plans

Residential Plot Plans Residential Plot Plans Planning & Development Services/Building Safety Division 1 Riverfront Plaza Ste. 110 Lawrence, KS 66044 (785)832-7700 Fax (785)832-3110 Email: buildinginspections@lawrenceks.org

More information

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS Detailed construction drawings for system extensions shall be prepared for approval with a submittal to the Authority. All construction

More information

Town of Mount Pleasant PRELIMINARY Design Review Submittal Check List June 1, 2014

Town of Mount Pleasant PRELIMINARY Design Review Submittal Check List June 1, 2014 Town of Mount Pleasant PRELIMINARY Design Review Submittal Check List June 1, 2014 This form is to be completed by either applicant or their representative and submitted with Preliminary Review plans.

More information

EIGHTH AMENDMENT TO THE PARVIN ROAD CORRIDOR TIF PLAN TAX INCREMENT FINANCING PLAN

EIGHTH AMENDMENT TO THE PARVIN ROAD CORRIDOR TIF PLAN TAX INCREMENT FINANCING PLAN EIGHTH AMENDMENT TO THE PARVIN ROAD CORRIDOR TIF PLAN TAX INCREMENT FINANCING PLAN I. Introduction The purpose of the Eighth Amendment to the Parvin Road Corridor Tax Increment Financing Plan (hereinafter

More information

REQUIREMENTS. for ENGINEERING SERVICES PUBLIC CONSTRUCTION PROJECTS

REQUIREMENTS. for ENGINEERING SERVICES PUBLIC CONSTRUCTION PROJECTS REQUIREMENTS for ENGINEERING SERVICES on PUBLIC CONSTRUCTION PROJECTS April, 2007 David W. Johnson Senior Engineer Design & Construction Requirements for Engineering Services on Public Construction Projects

More information

Project Name: County File No.: Checked by: For: Date:

Project Name: County File No.: Checked by: For: Date: Project Name: County File No.: Checked by: For: Date: Print name Firm or agency Items noted in the checklist shall be considered the minimum amount of information necessary for submission of construction

More information

Section 101. Street Design

Section 101. Street Design Section 101 Street Design This section establishes the uniform policies and procedures for the preparation of street design plans and construction requirements in the City of Irvine. It is not intended

More information

City of Starkville Development Review Committee Infrastructure Drawings Submittal Checklist for Site Plan Applications

City of Starkville Development Review Committee Infrastructure Drawings Submittal Checklist for Site Plan Applications City of Starkville Development Review Committee Infrastructure Drawings Submittal Checklist for Site Plan Applications Please submit ten (10) folded copies of the Infrastructure Drawings along with this

More information

SUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT

SUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT Case #: SUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT 171 North Ross Street, Suite 200 Auburn, AL 36830 (334) 501-3000 ~ Fax: (334) 501-7294 Applicant Name: Mailing Address: Email Address:

More information

1. Denver Water is not the provider. [C1 Cover] Baseline Response: Revised to show Thornton Water Department as the provider.

1. Denver Water is not the provider. [C1 Cover] Baseline Response: Revised to show Thornton Water Department as the provider. Nate Hatleback Project Manager City of Thornton 303 538 7694 Nate.Hatleback@cityofthornton.net Re: Topgolf Review The City of Thornton has provided comments regarding several submittals on June 14 th,

More information

Conceptual, Preliminary and Final Site Plan Review in Holladay City

Conceptual, Preliminary and Final Site Plan Review in Holladay City Conceptual, Preliminary and Final Site Plan Review in Holladay City The City of Holladay incorporated in December, 1999 and adopted its own zoning ordinance in May, 2000. All land use decisions are made

More information

PRECISE GRADING PLAN CHECKLIST

PRECISE GRADING PLAN CHECKLIST PRECISE GRADING PLAN CHECKLIST PUBLIC WORKS DEPARTMENT / ENGINEERING DIVISION 8130 Allison Avenue, La Mesa, CA 91942 Phone: 619. 667.1166 Fax: 619. 667.1380 Grading plans shall address both rough grading

More information

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS SECTION 2.1 INTRODUCTION... 1 (a) Objective...1 (b) Applicability...1 2.2 SUBMITTAL

More information

Legal Description & Site Plan Requirements and Layouts

Legal Description & Site Plan Requirements and Layouts Legal Description & Site Plan Requirements and Layouts Plot Plan * A plot plan shows the location of a house from an aerial view. * The site plan, also known as a plot or lot plan includes: 1. Site plan

More information

Single-Family Dwelling Submittal Requirements

Single-Family Dwelling Submittal Requirements Single-Family Dwelling Submittal Requirements The purpose of this guideline is to assist our customers in preparing for plan submittal. The items listed must be included before your plans can be accepted

More information

NOTICE. INFRASTRUCTURE: Currently, the District is responsible for infrastructure in Lakewood Ranch COD 5 including but not limited to the following:

NOTICE. INFRASTRUCTURE: Currently, the District is responsible for infrastructure in Lakewood Ranch COD 5 including but not limited to the following: This Instrument prepared by and recording return to: Lakewood Ranch Town Hall 8175 Lakewood Ranch Blvd. Lakewood Ranch, FL 34202 NOTICE DISCLOSURE OF PUBLIC FINANCING AND MAINTENANCE OF IMPROVEMENTS TO

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for

More information

Chapter 13 Plan Submittals

Chapter 13 Plan Submittals Chapter 13 Plan Submittals U30013.DOC 02/01/07 Chapter 13 Plan Submittals Section Topic Page 13.1 General 13.1 13.2 Subdivision Plans 13.1 13.3 Capital Improvement Project Plans 13.12 U30013.DOC 02/01/07

More information

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard

More information

DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS

DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS CITY OF ALBANY DEPARTMENT OF PUBLIC WORKS DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS Prepared By PUBLIC WORKS DEPARTMENT ALBANY, OREGON 97321 Telephone: (541) 917-7676 TABLE OF CONTENTS A 1.00

More information

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP CITY OF ANN ARBOR, MICHIGAN Public Services Area / Engineering 301 E. Huron Street, P.O. Box 8647 Ann Arbor, Michigan 48107 Phone (734) 794-6410 Fax (734) 994-1744 Web: www.a2gov.org Printed on recycled

More information