LUCAS MUNOZ SURVEY NO. 86 ABSTRACT NO. 488, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS.
|
|
- Coral Carroll
- 5 years ago
- Views:
Transcription
1 PALM VALLEY LOCATION MAP PARADISE TRACE SOL HALLIE PL VALLEY RD R.O.W. SQ.FT. D.R. FIR SIR G,E,T,CA D.P.R. O.P.R. N.T.S. 410 RAY ELLISON BLVD LEGEND SET 1/2" IRON ROD W/ CAP STAMPED "VICKREY PROP. COR." (UNLESS OTHERWISE NOTED) SIGN (AS NOTED) RIGHT-OF-WAY SQUARE FEET NOT TO SCALE DR 410 STORM WATER MANHOLE ELM VALLEY RAY ELLISON DR FOUND 1/2" IRON ROD W/ CAP STAMPED "VICKREY PROP. COR." (UNLESS OTHERWISE NOTED) SITE BLVD DEED RECORD OF BEXAR COUNTY, TEXAS WALNUT OFFICIAL PUBLIC RECORD OF REAL PROPERTY OF BEXAR COUNTY, TEXAS VALLEY GAS, ELECTRIC, TELEPHONE AND CABLE TELEVISION DR DEED AND PLAT RECORDS OF BEXAR COUNTY, TEXAS GN1 GN2 GN3 10M PARCEL ACRE DRAINAGE EASEMENT GENERAL NOTES FIR ACRE TRACT DEED REFERENCE: VOL , PG. 908, O.P.R. OWNER: SCC REALTY COMPANY, LTD. L8 POINT OF BEGINNING FIR PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE OWNER: SCC REALTY COMPANY, LTD. BURIED PIPELINE MARKER L7 STORM DRAIN STRUCTURE FIR INLET STRUCTURE N22 14'00"W ' 10M PARCEL ACRE DRAINAGE EASEMENT C1 STORM DRAIN STRUCTURE 10L GAS EASEMENT FIR 10G 10H 10I 10J 10K 10L 10M SCHEDULE B EXCEPTIONS CURVE C1 C2 C3 LENGTH ' ' ' RADIUS ' ' ' CURVE TABLE DELTA TANGENT 25 38'46" ' 18 12'14" ' 58 23'04" ' CHORD BEARING S50 31'02"E S46 47'47"E N51 28'10"W CHORD ' ' ' AS-SURVEYED DESCRIPTION Being a acre (181,065 square feet) tract of land out of the Lucas Muñoz Survey No. 86, Abstract No. 488, and the Maria F. Rodriguez Survey No. 4, Abstract No. 16, New City Block 15228, situated in the City of San Antonio, Bexar County, Texas, said acre tract being comprised of a portion of a acre tract conveyed from Ray Ellison Self Storage, LLC to S&K Development Company, Inc. by Warranty Deed recorded in Volume 15042, Page 904, Official Public Records of Real Property (O.P.R.) of Bexar County, Texas (all records cited herein are recorded in Bexar County, Texas), a acre tract conveyed from James M. Schneider to S&K Development Company, Inc. by Special Warranty Deed recorded in Volume 17563, Page 214, O.P.R. and a portion of Old Dwyer Road, a closed and vacated right-of-way by Ordinance , said acre tract being more particularly described as follows, with all bearing being referenced to North American Datum of 1983, Texas Coordinate System, South Central Zone: BEGINNING at a found ½ iron rod with cap stamped VICKREY PROP. COR. at a point of curvature to the right, on the south right-of-way (ROW) line of Ray Ellison Blvd. (ROW varies in width), said point being the intersection of the centerline of said closed and vacated Old Dwyer Road and the south right-of-way line of said Ray Ellison Blvd., said corner being the northwest corner of land conveyed to S&K Development Company, Inc. by said ordinance and being a corner of land conveyed to SCC Realty Company, Ltd. by said ordinance, for the northwest corner of the herein described tract; THENCE along the southwest right-of-way line of said Ray Ellison Blvd., the following two (2) calls: 1.)along said curve to the right, along the northeast line of said closed and vacated Old Dwyer Road and said acre tract, an arc length of feet, with a radius of feet, a central angle of 25 38'46, and a chord bearing and distance of S50 31'02 E, feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. at a tangent point, for a corner of the herein described tract, and 2.)S37 43'27 E, along the northeast line of said acre tract, a distance of feet to a found ½ iron rod with yellow cap stamped BIG SKY RPLS 5418 at the most northerly corner of a acre tract conveyed from S&K Development Company, Inc. to City of San Antonio by Warranty Deed recorded in Volume 17675, Page 1362, O.P.R., for a corner of the herein described tract; THENCE departing said southwest right-of-way line of Ray Ellison Blvd., into and across said acre tract and along the northwest and southwest lines of said acre tract, the following three (3) calls: 1.)S52 16'33 W, a distance of feet to a found ½ iron with yellow cap stamped BIG SKY RPLS 5418 at the most westerly corner of said acre tract, for an interior corner of the herein described tract, 2.)S37 43'27 E, a distance of feet to a found ½ iron rod with yellow cap stamped BIG SKY RPLS 5418 at a point of curvature to the left, for a corner of the herein described tract, and 3.)along said curve to the left, an arc length of feet, with a radius of 1, feet, a central angle of 18 12'14, and a chord bearing and distance of S46 47'47 E, feet to a set ½ iron rod with cap stamped VICKREY PROP. COR. on a northwest line of the remaining portion of Lot 2, Block 146, New City Block 15228, Freedom Hills Apartment, an addition to the City of San Antonio, according to plat thereof recorded in Volume 9694, Page 180, Deed and Plat Records, for the most easterly corner of the herein described tract; THENCE S34 19'37 W, departing said southwest line of acre tract, into and across said acre tract, closed and vacated Old Dwyer road and acre tract and along said northwest line of remaining portion of Lot 2, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. on the southwest line of said acre tract, same point also being an interior corner for said Lot 2, for the most southerly corner of the herein described tract; CIVIL ENVIRONMENTAL SURVEY DESCRIPTION NO. DATE REVISIONS Country Parkway San Antonio, TX Telephone: (210) TBPLS Firm Registration No: FIR-RED CAP STAMPED "RPLS 4540" L6 L5 FIR FOUND 3/8" IRON ROD IN CONCRETE MONUMENT REMAINING PORTION OF LOT 2, BLOCK 146, N.C.B FREEDOM HILLS APARTMENT (VOL. 9694, PG. 180, D.P.R.) DEED REFERENCE: VOL , PG. 1297, O.P.R. OWNER: JAMES M. SCHNEIDER C3 S37 43'27"E ' PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE OWNER: S&K DEVELOPMENT COMPANY, INC. UTILITY RESERVATION ORDINANCE FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" ACRE TRACT (181,065 SQ. FT.) OUT OF A ACRE TRACT CONVEYED FROM RAY ELLISON SELF STORAGE, LLC. TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 904, O.P.R.) A ACRE TRACT CONVEYED FROM JAMES M. SCHNEIDER TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 214, O.P.R.) AND A PORTION OF CLOSED AND VACATED OLD DWYER ROAD BY ORDINANCE L2 L1 FIR-YELLOW CAP STAMPED "BIG SKY RPLS 5418" BURIED PIPELINE MARKER ACRE TRACT JAMES M. SCHNEIDER TO S&K DEVELOPMENT COMPANY, INC. (VOL , PG. 214, O.P.R.) C2 APPROXIMATE LOCATION OF SURVEY LINE EDGE OF PAVEMENT MARIA F. RODRIGUEZ SURVEY NO. 4 ABSTRACT NO. 16, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS. PARCEL 19369A ACRE TRACT S&K DEVELOPMENT COMPANY, INC. TO CITY OF SAN ANTONIO (VOL , PG. 1362, O.P.R.) INLET STRUCTURE L3 10L SIR DEPRESSION BURIED PIPELINE MARKER THENCE along the common line of said Lot 2 and acre tract, the following three (3) calls: 1.)N80 38'43 W, a distance of feet to a found 3/8 iron rod in concrete monument at a point of curvature to the right, for a corner of the herein described tract, 2.)along said curve to the right, an arc length of feet, with a radius if feet, a central angle of 58 23'04, and a chord bearing and distance of N51 28'10 W, feet to a found 3/8 iron rod in concrete monument at a point of tangency, for a corner of the herein described tract, and 3.)N22 14'00 W, a distance of feet to a found ½ iron rod with red cap stamped RPLS 4540 at the most northerly corner of said Lot 2, same point also being the southeast corner of a acre tract conveyed to SCC Realty Company, Ltd. by Deed recorded in 17338, Page 908, O.P.R., same point also being the southwest corner of said land conveyed to SCC Realty Company, Ltd. by said ordinance, for a corner of the herein described tract; THENCE N80 32'32 E, along the south line of said land owned by SCC Realty Company, Ltd. by said ordinance, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR. at the southeast corner of said land owned by SCC Realty Company, Ltd., same point also being the most northerly corner of said acre tract and lying on the centerline of closed and vacated Old Dwyer Road, for an interior corner of the herein described tract; THENCE continuing along said centerline of closed and vacated Old Dwyer Road, along the east line of said land owned by SCC Realty Company, Ltd. by said ordinance and along the west line of land owned by S&K Development Company, Inc. by said ordinance, the following three (3) calls: 1.)N22 14'00 W, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR., for a corner of the herein described tract, 2.) N27 57'40 W, a distance of feet to a found ½ iron rod with cap stamped VICKREY PROP. COR., for a corner of the herein described tract, and N40 40'12 W, a distance of feet returning to the POINT OF BEGINNING and containing acres (181,065 square feet) of land. CAT. 1A, COND. II LAND TITLE SURVEY LAND TITLE SURVEY OF A ACRE (181,065 SQUARE FEET) TRACT OF LAND OUT OF THE LUCAS MUÑOZ SURVEY NO. 86, ABSTRACT NO. 488, AND THE MARIA F. RODRIGUEZ SURVEY NO. 4, ABSTRACT NO. 16, NEW CITY BLOCK 15228, SITUATED IN THE CITY OF SAN ANTONIO, BEXAR COUNTY, TEXAS. 6/7/ :49:52 PM \ ranguiano R:\ \Survey\dwg\SH_SURVEY01-1.dwg LUCAS MUNOZ SURVEY NO. 86 ABSTRACT NO. 488, N.C.B CITY OF SAN ANTONIO, BEXAR, TEXAS. FOUND 3/8" IRON ROD IN CONCRETE MONUMENT L4 FIR PRELIMINARY, THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWED OR RELIED UPON AS A FINAL SURVEY DOCUMENT. PREPARED FOR: DATE S&K DEVELOPMENT COMPANY, INC c PROJ NO. DATE: SCALE 1" = 50' OF 1 1 DRAWN BY: R.M.A. APPROVED BY: S.H. FIELD CREW: J.M.
2
3 FH-2 CURB BLDG-4 12,092 SF ANE FIRE LANE R GUTTE SITE PLAN & CURB BLDG-5 18,131 SF TANK 1 GAL. 18 0K FFE=76 9 CONC 33' DIA. PUMP HOUSE WATER WELL FH-1 FIRE L BLDG-3 18,358 SF N TIO N E DET OND P EX 2 FH SEPTIC FIELD 2772 SF BLDG-2 TWO-STORY 14,195 SF OFFICE T IDEN RES = E FF File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: 7-SITE Plotted: 3/28/2018 3:45:17 PM Plotted by: Albert Rubio UTTER FIRE IO ENT T E AD COS &G CURB LANE ND N PO R LN TER 8" WT & GUT EX 1 FH 7 OF 10
4 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: EX-CONDITIONS Plotted: 9/20/ :15:59 AM Plotted by: Albert Rubio COSA DETENTION POND SCALE: 1":40' 0' 50' 100' 8 OF 16 EXISTING CONDITIONS
5 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: EROSION Plotted: 9/20/ :17:29 AM Plotted by: Albert Rubio LOC LOC LOC LOC LOC LOC LOC AREA (SEE DETAIL) WASHOUT & LOC CONSTRUCTION LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF LOC LOC LOC LOC LOC SF SF SF SF SF SF SF COSA DETENTION POND SCALE: 1":40' 0' 100' 200' LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SPOILS AREA CONCRETE SF SF SF SF SF SF LOC LOC SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF STABILIZED ENTRANCE LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC SF SF LOC LOC LOC LOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOCLOC LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF SF LOC LOC LOC LOC LOC LOC SF SF SF SF SF SF LOC LOC LOC LOC 8 OF 16 STORM WATER POLLUTION PREVENTION PLAN
6 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA-EX OFFSITE Plotted: 9/20/ :18:42 AM Plotted by: Albert Rubio OS AC DA AC COSA DETENTION POND 0' 100' 200' SCALE: 1":40' NE CORNER EX. CULVERTS NE CORNER EX. DETENTION POND DA AC DA AC OS AC OS AC LEGEND DRAINAGE AREAS TIME AND CONCENTRATION DRAINAGE AREA FLOW ARROW SE CORNER EX. 4X4 AREA INLET 8 OF 16 DRAINAGE AREA MAP-EXISTING CONDITIONS
7 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA Plotted: 9/20/ :19:38 AM Plotted by: Albert Rubio S=0.25% OS AC 0.44 AC FFE=767.5 HOUSE PUMP WELL WATER DA-3 S=5.0% 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND HP SCALE: 1":40' 0' 100' 200' LEGEND DRAINAGE AREAS TIME AND CONCENTRATION DRAINAGE AREA FLOW ARROW NE CORNER EX. CULVERTS NE CORNER EX. DETENTION POND FDC FH S=5.5% 14,195 SF TWO-STORY SEE EXISTING DRIANAGE MAP FOR OFFSITE TOPOGRAPHY BLDG-2 DA AC HP S=0.6% 18,131 SF BLDG-5 12,092 SF BLDG-4 18,358 SF BLDG-3 DA AC OS AC OS AC BP AC FH S=0.8% S=7.8% S=0.7% HP BP AC S=9% T/W= T/W=771.5 RAMP S=7:1 7' W ACCESS T/W= POND DETENTION T/W= BP AC T/W=770.5 SE CORNER EX. 4X4 AREA INLET 8 OF 16 DRAINAGE AREA MAP-DEVELOPED CONDITIONS
8 EXISTING CONDITIONS DEVELOPED CONDITIONS CONCRETE REINFORCEMENT DETAIL (NOT TO SCALE) CONC. SPLASH PAD 3' W X 4" H REINF.CONC. SLAB ON 2" SAND CUSHION W/#3 OC 2' CURB (TYP.) EACH WAY 3' CURB-CUT (TYP) #5 18" OC EACH WAY 8" CONC. POND WALL W/#4 18" OC 8" CONC. POND WALL EACH WAY W/#4 18" OC EACH WAY 2' L X 8"H CONC. FOOTING 3-#5 CONT. HORIZ. BARS #5 #5 18" OC 18" OC EACH WAY EACH WAY CONC. SPLASH PAD 3' W X 4" H REINF.CONC. SLAB ON 2" SAND CUSHION W/#3 OC EACH WAY 2' L X 8"H CONC. FOOTING 3-#5 CONT. HORIZ. BARS DRAINAGE CALCULATIONS File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DA CALCS Plotted: 9/20/ :20:03 AM Plotted by: Albert Rubio NOTE: REINFORCEMENT SHALL ACCURATELY BE PLACED AT SLAB MID DEPTH OR WALL CENTER AND HELD FIRMLY IN PLACE BY MEANS OF BARS SUPPORTS OF ADEQUATE STRENGTH AND NUMBER THAT WILL PREVENT DISPLACEMENT AND KEEP STEEL AT ITS PROPER POSITION DURING THE PLACEMENT OF THE CONCRETE. IN NO INSTANCE SHALL THE STEEL BE PLACED DIRECTLY ON THE SUBGRADE OR SAND CUSHION LAYER. 12 OF 18
9 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: SITE Plotted: 9/20/ :20:29 AM Plotted by: Albert Rubio BLDG-4 12,092 SF FFE=767.5 HOUSE PUMP 12" WTR LN 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND EASEMENT WELL WATER SCALE: 1":40' 0' 100' 200' FDC 8" WTR LN FH-1 14,195 SF TWO-STORY BLDG-2 8" WTR LN 18,131 SF BLDG-5 18,358 SF BLDG-3 FH-2 DRAINAGE POND DETENTION 8 OF 16 SITE PLAN
10 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: DIMENSION Plotted: 9/20/ :21:05 AM Plotted by: Albert Rubio 12,092 SF FFE=767.5 HOUSE BLDG-4 PUMP 12" WTR LN 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K RESIDENT TANK 1 TANK 2 OFFICE COSA DETENTION POND WELL WATER SCALE: 1":40' 0' 100' 200' FDC 8" WTR LN FH-1 14,195 SF TWO-STORY BLDG-2 8" WTR LN 18,131 SF BLDG-5 18,358 SF BLDG-3 FH-2 POND DETENTION 8 OF 16 DIMENSION CONTROL PLAN
11 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: GRADING 1 Plotted: 9/20/ :21:37 AM Plotted by: Albert Rubio S=0.25% 775 S=7.8% 31' DIẠ CONC CONC 31 DIA. GAL. 93K GAL. 93K TANK 1 TANK 2 COSA DETENTION POND SCALE: 1":20' 0' 50' 100' WATER WELL 12" WTR LN RESIDENT 765 FFE=767.5 HOUSE PUMP OFFICE S=5.0% HP FDC 8" WTR LN FH-1 S=5.5% 14,195 SF TWO-STORY BLDG HP S=0.6% 8" WTR LN HP 774 MAH LINE 8 OF 16 GRADING PLAN ONE
12 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: GRADING 2 Plotted: 9/20/ :21:59 AM Plotted by: Albert Rubio MAH LINE 8" WTR LN HP S=0.6% HP ,131 SF BLDG-5 18,358 SF BLDG-3 FH ,092 SF BLDG S=0.8% S=0.7% SCALE: 1":20' 0' 50' 100' S=9% T/W= T/W=771.5 RAMP S=7:1 7' W ACCESS DETENTION POND T/W= T/W= T/W= OF 16 GRADING PLAN TWO
13 10' 20' 7' CONC CHAN POND FL(IN)= ' 100 YR WSE= ' 20' T/WALL= ' T/WALL= :1 0' 0' 25 YR WSE= X3 CONC PAD POND FL(OUT)=766 4' W ROCK AREA=766.7 :1 7 = S S=0.5% 100 YR WSE= YR WSE= YR WSE=768.3 FL= ' CONC PAD=766.5 FINISH GRADE 5 YR WSE=768.3 PROPERTY LINE PROPERTY LINE T/WALL=770.5 T/WALL=771.5 S= DETENTION POND SECTION "A-A" SCALE: 1" = 10' DETENTION POND SECTION "B-B" SCALE: 1" = 10' DETENTION POND SECTION "C-C" SCALE: 1" = 10' 7' W ACCESS RAMP S=7:1 DETENTION POND T/WALL=770.5 T/WALL= YR WSE= YR WSE= YR WSE= " ORIFICE FL=766 FL= FINISH GRADE 3X3 CONC PAD POND FL(OUT)=766 B T/W=770.5 TOP WALL= T/ W =7 C.5 B 71 DETENTION POND (OUTLET) 7.25" DIA. ORIFICE=766.0 DETENTION POND PLAN 766 A 5' CONC PAD W/ENERGY DISSIPATORS =766 30' ' 30' DETENTION POND OUTFALL (NOT TO SCALE) DETENTION DETENTION POND (OUTLET) 1.25' L WEIR= ' 10' PROPERTY LINE 10' T/ W = ' 0' 76 File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: POND DETENTION Plotted: 9/20/ :22:25 AM Plotted by: Albert Rubio A T/W=770.5 C SCALE: 1" = 10' 770.5T/W=771.5 POND OUTFALL 1.25' WEIR FL= OF 18
14 HP " R PUM HO P FFE USE = " W T 1+00 BEGIN WTR LN A 1-93,000 GALS. WATER TANK No " GATE VAVLE 1-8" 22.5 BEND 25 NE 24 "R FDC FH-1 30' 60' BLDG-5 18,131 SF FH-2 CURB WTR LN A 1-514" FIRE HYDRANT 1-8"X6" TEE MJ 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 11.5 L.F. 6" D.I. PIPE CL WTR LN 1-8" BEND SCALE: 1":30' 0' 8" WTR LN 2+30 WTR LN 1+20 WTR LN A 17'X17' PUMP HOUSE 1-93,000 GALS. WATER TANK No " 45 BENDS 1-8" GATE VAVLE 1-8" GATE VAVLE BEND SEE PUMP HOUSE DETAIL WTR LN A 1-FIRE DEPT. CONNECTION 1-8"X6" TEE MJ 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 11.5 L.F. 6" D.I. PIPE CL. 350 BLDG-4 12,092 SF FIRE L A CP 770. R LN FIRE L ANE CP N BLDG-3 18,358 SF TR L HP BLDG-2 TWO-STORY 14,195 SF OFFICE WATER WELL 12" W E NT RESID FFE=7 2 TANK K 3 9. GAL 68 7 = E F F. 31 DIA CONC TANK 1 3K GAL = E FF CONC 31' DIA T/W= CESS AC 1 7' W P S=7: 8. 6 M 6 7 RA T/W = D PON N IO ENT T E AD COS FIRE CU LANE P 24" RC UTTER RB & G TER & GUT CURB & GUT TER WTR LN A 1-514" FIRE HYDRANT 1-8"X6" TEE MJ 1-8" CAP 1-6" GATE VALVE MJ 1-6" VALVE BOX COMPLETE 10 L.F. 6" D.I. PIPE CL ' FIRE PUMP: FAIRBANKS NIJHUIS HORIZONTAL SPLIT CASE 6" F MODEL PUMP 1,500 GPM 2" WATER LINE TO APARTMENT/OFFICE FIRE SPRINKLER SYSTEM 2" WTR 1. ALL PIPE FITTINGS SHALL BE CAST IRON FLANGE TYPE WITH DUCTILE IRON PIPE WITHIN THE PUMP HOUSE. 2. ALL PIPE FITTINGS AND PIPE SHALL BE AT LEAST 1 FT ABOVE PUMP HOUSE CONCRETE FLOOR AND INSTALLED WITH PIPE SUPPORT. 3. NORMAL AND EMERGENCY LIGHTING SHALL BE PROVIDED AT THE PUMP HOUSE. 12"X2" WATER SERVICE TAP THERMOSTATICALLY ACTIVATED VENT FAN AND PASSIVE Dbl LOUVER VENT STANDARD HOSE SPIGOT ATTACHED TO EXTERIOR WALL 11.8' 12" FLG X PE PIPE 6' GARAGE DOOR FIRE DEPARTMENT NOTES: EXHAUST COLLAR THRU WALL (TYP.) 3.0' 2. THE CITY OF MANOR FIRE DEPARTMENT SHALL HAVE A RIGHT OF ENTRY ONTO PROPERTY TO INSPECT ANY PORTION OF THE FIRE PROTECTION WATER SYSTEM AS DEEMED NECESSARY IN THE CITY'S REASONABLE DETERMINATION. 3. THE TANKS, PUMPS, AND OTHER IMPORTANT ASPECTS OF FIRE PROTECTION SYSTEM SHALL BE INSPECTED QUARTERLY BY QUALIFIED PERSONNEL ASSIGNED BY HOME OWNERS ASSOCIATION. 6. FINAL INSPECTION REQUIRED BY MANOR FIRE DEPARTMENT AFTER FIRE PROTECTION SYSTEM HAS BEEN INSTALLED. 2" WTR 7. THE DIESEL TANK SHALL BE A 119 GAL CAPACITY DOUBLE WALL TANK AS RECOMMENDED BY THE AURORA PUMP SUPPLIERS. THE MINIMUM TANK SIZE REQUIRED WAS CALCULATED BASED ON 100% OF HP PLUS EXPANSION 5% AND SUMP RESERVE 5% 64 HP X 1.10 = 70.4 GAL CAPACITY REQUIRED ' 6. FIRE PUMP HOUSE SHALL BE CONSTRUCTED WITH AN AUTOMATIC SPRINKLER SYSTEM PER NFPA SEC KNOX KEY BOX SHALL BE PROVIDED AT PUMP HOUSE FOR FIRE DEPT. ACCESS.. 5. FIRE PUMP AND DIESEL MOTOR SHALL BE INSTALLED ON CONCRETE BASE PER MANUFACTURER'S INSTRUCTIONS. 1. A COMPLETE OPERATION MANUALS SHALL BE PROVIDED THAT INCLUDES PUMP CURVES, ELECTRICAL SCHEMATIC AND COMPONENTS OF THE CONTROL PANEL, AND PUMP MAINTENANCE RECOMMENDATIONS WITH REQUIRED FREQUENCIES AND WRITTEN WARRANTY FROM PUMP SUPPLIERS TO HOME OWNERS ASOCIATION AND KEPT ON FILE FOR FUTURE RERENCE. KNOX KEY BOX DIESEL ENGINE EXHAUST MUFFLER TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 7. A REPORT OF EACH INSPECTION, TEST, AND RESULTS MUST BE KEPT ON FILE AND BE READILY AVAILABLE TO THE MANOR FIRE DEPT UPON REQUEST OR AS REQUIRED BY FIRE CODE. 8. ANY OPERATIONAL DEFICIENCIES MUST BE NOTED AND INCLUDED IN THE REPORT TOGETHER WITH RECOMMENDED REMEDIATION NECESSARY TO BRING THE FIRE PROTECTION TANKS AND PUMP INTO PERMIT COMPLIANCE REGARDING SYSTEM OPERATION. FIRE PROTECTION - WATER PLAN PUMP HOUSE NOTES: 2" WTR 20' - 2" WTR PVC Sch ALARM HORN/BELL SHALL BE ACTIVATED WHEN FIRE PUMP IS ON AND SUCTION INTAKE IS DRAINING TANKS. PUMP HOUSE DETAIL (NOT TO SCALE) ALARM HORN/BELL (WEATHER PROOF TYPE) SHALL BE INSTALLED ON EXTERIOR WALL OF PUMP HOUSE AND BE ACTIVATED WHEN FIRE PUMP IS ONAND SUCTION INTAKE OPERATIONAL PASSIVE Dbl LOUVER VENT 8" WATER LINE PVC C900 ALARM LIGHT IN VAPOR PROOF FIXTURE WITH A 40-WATT FLASHING RED LIGHT SHALL BE INSTALL ON EXTERIOR WALL FOR FIRE PUMP FAILURE INDICATOR File: C:\Users\Albert Rubio\Documents\Ray Ellison San Antonio\Drawings\XREF\BASE-RAY ELLISON.dwg Layout: WATER Plotted: 9/20/ :22:51 AM Plotted by: Albert Rubio 12" WTR TO TANKS 8 OF 16
15
16
LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)
MEMORANDUM MICHAEL B. FLETCHER, P.E. COUNTY ENGINEER 327 N. Ashley Street Valdosta, GA 31601 Telephone: (229) 671-2424 Fax: (229) 245-5299 mfletcher@lowndescounty.com LOWNDES COUNTY ENGINEERING PLAN REVIEW
More informationCITY OF MUSKEGO DRAFTING STANDARDS
CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under
More informationSECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS
SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of
More informationPorter County Plan Commission
Plan Type: Development Plan Administrative DRC PC Primary Plan Administrative DRC PC Secondary Plat/Replat Administrative DRC PC PUD Conceptual Detailed Final Project Information Project Name: Developer
More informationAuthorized Agent: City of Manassas Check List Attached: Contact: Address: Phone Number: Fax Number: Developer s Name: Phone Number:
CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street Room 201 Manassas, Virginia, 20110 Phone: 703-257-8278 Fax: 703-257-5831 Application Date: APPLICANT
More informationCITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)
CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION
More informationUTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1
UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.
More informationCHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN
N/A Waiver (1) Four (4) copies of application form. (2) Fifteen (15) copies of plan (3) Subdivision/site plan application fee & professional review escrow deposit (4) Variance application fee & professional
More informationList of Figures. List of Forms
City of Columbia Engineering Regulations PART 1: SUBMISSION OF PLANS Table of Contents Paragraph Description Page No. 1.1 General 1-1 1.2 Engineer s Report 1-1 1.3 Plans 1-3 1.4 Revisions to Approved Plan
More informationSECTION SITE SURVEYS
SECTION 02 21 13 SITE SURVEYS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section to specify survey required before design
More informationBRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006
Project Name: BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Phase: Unit: # Lots: Development Type (residential, commercial, industrial, etc.) Braselton Project No.
More informationCity of Massillon Site Plan Checklist
City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete
More informationVICINITY MAP SCALE 1'' = 2000'
LOCATED IN THE SOUTHWEST QUARTER OF SECTION AND THE WEST HALF OF SECTION 4, TOWNSHIP SOUTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, SHEET OF 5 E47 TOLL ROAD CASE NO. ZAX 26-4 LEGAL DESCRIPTION: A
More informationCITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS
CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------
More informationResidential Room Addition / Remodel Submittal Requirement Checklist
City of Elko Building Department 1753 College Avenue Elko, Nevada 89801 (775) 777-7220 fax (775) 777-7229 Residential Room Addition / Remodel Submittal Requirement Checklist TWO COMPLETE SETS OF PROPERLY
More informationCHAPTER 11. Plan Standards
CHAPTER 11 Plan Standards A. Introduction The city requires uniform public improvement plans for ease of record keeping and understanding. The following standards govern most plan submittals to the city.
More informationAPPLICATION FOR SITE PREPARATION PERMIT
Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision/Plat Name: Location Description/ Nearest Intersection: Acreage: APPLICATION FOR SITE PREPARATION PERMIT No.
More informationCITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS
CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE E-10 ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS The City of Lompoc has determined that the Engineering Division should administer and issue Encroachment
More informationLantz-Boggio Architects 5650 DTC Parkway, Suite 220 Englewood, CO UPPER LEVEL 113' - 4"
CASTLE PINES NORTH FILING NO. 9. LOTS,,,, TRACT B AND TRACT J A PORTION OF THE N / OF SECTION, TS, RW, SIXTH P.M.. ACRES XXXX-XXX ' - " 00 00 0 KEYNOTE LEGEND 00 00 0 0 0 0 00 0 ' - " ' - " ' - " 00' -
More informationApplication for Site Plan Review
Application for Site Plan Review 3275 Central Blvd., Hudsonville, Michigan 49426-1450, 616.669.0200 fax 616.669.2330 It is STRONGLY recommended that any application that must go before the Planning Commission
More information1.1 GENERAL RECORD DRAWING REQUIREMENTS
Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has
More informationMAY J. Collins Engineering Associates, LLC San Jose Blvd. Jacksonville, Florida 32223
PROJECT LOCATION: 95 NOCATEE PARKWAY PONTE VEDRA, FL. 38 J. Collins Engineering Associates, LLC 56-3 San Jose Blvd. Jacksonville, Florida 32223 NOT TO SCALE 904-262-42 sm sm ON DRAWING WHERE SECTION OR
More informationCITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST
CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation
More informationSection E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02
Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing
More informationAGENDA Planning Review Committee Pinellas County Planning Department 310 Court Street, 1 st Floor Conference Room 119 April 8, :00 A.M.
AGENDA Planning Review Committee Pinellas County Planning Department 310 Court Street, 1 st Floor Conference Room 119 April 8, 2013 10:00 A.M. Case Summary Review: 1. CU-3-1-13 Berati # 2, LLC 2. Z/LU/CU-7-3-13
More informationPLANNING AND DEVELOPMENT
OVERVIEW Effective January 1, 1992 all applications for multi-family residential and all non-residential building permits require site plan approval before permit issuance. All new developments and existing
More informationResidential Construction Checklist Single and Two Family Construction
DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy
More informationAnne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist
Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated
More informationCITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION:
CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION: LOG NO.: LEGEND REVIEW REVIEWED BY DATE / - Requirement satisfied 1 O Requirement not satisfied 2?
More informationACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).
ACSA PLAN REVIEW CHECKLIST (Guideline Only) Revised: December 3, 2015 General (1) Proper Title (2) Vicinity map on first sheet. (3) Date and latest plan revision. (4) Standard water and sewer general plan
More informationAppendix C Construction Details
7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses
More informationNEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST
NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST Project Name Checked By Date Designer Check List marks to be
More informationCITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST
CITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST Tract Number and Subdivision Name: Engineering Firm: Contact Person: Address: City: State: Zip: Phone No. Fax No. Assessor s Parcel Number(s) Tentative
More informationDANE COUNTY ORDINANCE AMENDMENT NO: Internal Tracking Number: RECU25846
DANE COUNTY ORDINANCE AMENDMENT NO: 10314 Internal Tracking Number: RECU25846 Amending Section 10.03 relating to Zoning Districts in the Town of Cottage Grove. The Dane County Board of Supervisors does
More informationGrease Interceptor Design Checklist
CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private
More informationItem 2. September 28, 2017
September 28, 2017 Item 2 Applicant: Georgetown Development Location: 190 N 1100 W Prepared by: Sean Conroy, Community Development Director Public Hearing: No Zone: PRD-1 Attachments: 1. Findings. 2. Project
More informationCommunity & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS
Community & Economic Development Department Planning Division 14177 Frederick Street PO Box 8805 Moreno Valley, CA 92552-0805 (951) 413-3206 Fax (951) 413-3210 SECOND UNITS Completed and Signed Project
More informationAnne Arundel County Dept. of Inspections and Permits Storm Drain Checklist
Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated
More informationOil-Water Separator Design Checklist
CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water
More information3. The PAC (Permit Application Center) will notify the design professional of plan review results.
Planning and Development Dept. Infrastructure Division P.O. Box 11706, or 155 Johnston Street Rock Hill, South Carolina 29731-1706 Phone: 803-329-5515 FAX: 803-329-7228 www.cityofrockhill.com AS-BUILT
More informationAPPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST
VI-K -1 of 8 APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST Final Submittal Major Subdivision Project Name Subdivision Number Location (Street
More informationCITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST
CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation
More informationPROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic
GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable
More informationMinor Site Plan Application and Checklist Land Disturbing Activities
Minor Site Plan Application and Checklist Land Disturbing Activities INSTRUCTIONS: Please provide the requested information below. The Development Services Department reviews each site plan submittal based
More informationCabaniss Engineering Inc.
280 North River Church 4215 Rice Mine Road NE -1529 North River Church Subdivision Plat Book 2010, Page 131 Deed Book 550 Page 761 4 18,427 sf 67.7' 5 14,367 sf 60.2' 65.0' 3 13,546 sf 35.2' 6 35' X 277.99
More informationPRELIMINARY PLAT CHECK LIST
Name of Proposed Subdivision: The following items must be included with the initial submittal of a Preliminary Plat: Application, filled out completely Project Narrative Pre-application Conference Report
More informationB.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST
B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST YES* GENERAL SUBMISSION ITEMS Does the submission include: 1. Thirteen (13) copies of completed Application Form? 2. Thirteen (13) copies of the Preliminary
More informationFundamentals III CHAPTER PROJECT EXERCISE
CHAPTER 4 Fundamentals III PROJECT EXERCISE This project exercise provides point-by-point instructions for setting up the drawing with layers and then creating the objects shown in Figure P4 1. FIGURE
More informationDOCUMENT MINIMUM CONSTRUCTION DRAWING REQUIREMENTS FOR PRELIMINARY REVIEW/APPROVAL 1.2. GALVESTON COUNTY CONSOLIDATED DRAINAGE DISTRICT (GCCDD)
DOCUMENT 01105 FOR PRELIMINARY REVIEW/APPROVAL PART I: SUBMITTAL 1.1 CITY OF FRIENDSWOOD (COF) A. Submit four (4) copies of drawings. B. Submit by 5:00 PM a minimum of fourteen calendar days (14 cd) prior
More informationSECTION III SUBMITTALS AND APPROVALS
SECTION III SUBMITTALS AND APPROVALS In order to expedite the approval process of new water distribution system and sanitary sewer collection system extensions, the Hilton Head No. 1 Public Service District
More informationSITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS
INCORPORATED VILLAGE OF ROCKVILLE CENTRE BUILDING DEPARTMENT SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS Presubmission - Prior to a formal submission, the applicant should meet in person with
More informationSurvey Requirements. Design Guidelines and Standards. June Office of the University Architect
Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements
More informationZoning District: R-1, R-2, and R-4 Applicant: Exeter Rose Farm, LLC, 953 Islington Street #23D Portsmouth, NH 03801
2220.00, Town Planner Town Planning Office, Town of Exeter 10 Front Street Exeter, NH 03833 Re: Exeter Rose Farm Subdivision Design Review Engineering Services Exeter, New Hampshire Site Information: Tax
More informationSewer Line Extension Permit Design Checklist
CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line
More informationJune 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA
June 10, 2014 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA ADDENDUM NO. 5 BID NO. Y14-792 PH IFB EAST SERVICE AREA POTABLE WATER AND RECLAIMED WATER STORAGE AND REPUMP FACILITY BID OPENING: June
More informationManhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard
More informationSite Plan/Building Permit Review
Part 6 Site Plan/Building Permit Review 1.6.01 When Site Plan Review Applies 1.6.02 Optional Pre- Application Site Plan/Building Permit Review (hereafter referred to as Site Plan Review) shall be required
More informationPART 4 STANDARD DRAWINGS FOR CONSTRUCTION
4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of
More informationP.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint)
P.L., CHAPTER, approved October, Assembly, No. 0 (First Reprint) 0 0 0 AN ACT concerning the approval and filing of maps and amending P.L.0, c.. BE IT ENACTED by the Senate and General Assembly of the
More informationTooker Family Residence
110 25 90 E B M U D (N) POP-UP DRAIN + DRAIN ROCK BASIN DISCHARGE OF SURFACE DRAINS AND DOWNSPOUTS - SHEET FLOW ACROSS LANDSCAPE NOTE: SEE SHEET S2.0.1 FOR FOUNDATION + RAIN WATER DRAINAGE DESIGN 143.57'
More information7000 Fifteen Mile Road Sterling Heights, Michigan
7000 Fifteen Mile Road Sterling Heights, Michigan Industrial Building With Excess Land and Rail Access As exclusive agents, we are pleased to offer the following property for lease: 128,648 Sq. Ft. Completely
More informationWashington County Road Engineering Plan Submittal/Review Checklist
Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should
More informationClarifications in italics added July 2018
SECTION 10000 RECORD DRAWING CHECKLIST Clarifications in italics added July 2018 All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes,
More informationINSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September
More informationDEVELOPMENT PLAN CHECKLIST
Project Identification Information: DEVELOPMENT PLAN CHECKLIST 1.0 GENERAL 1.1 Additional information as required by specific Land Use 1.2 All sheets to include sheet number ( of ) 1.3 Seal and signature
More informationSANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS
SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS All plans for sanitary sewer main extensions, improvements and modifications
More informationTown of Westlake Construction Plans Review Checklist
CONSTRUCTION PLANS CONTENTS All Drawings 24 x 36 Cover Sheet Final Plat Site Plan Demolition Plan Utility Plan Drainage Area Map and Calculations Paving Plan & Profile Sheets Storm Drain Plan & Profile
More informationExisting and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.
PLAN REQUIREMENTS The plans for street design shall conform to the requirements of Sections 3 and 4. The following requirements shall also be shown on the plans where applicable. Road and Storm Plans:
More information3. DESIGN SPECIFICATIONS
Schedule H to Bylaw 7452, Subdivision Bylaw Page 10 3. DESIGN SPECIFICATIONS 3.1 General 3.1.1 The Design Specifications apply to the design of sanitary sewers, storm drains, waterworks, roadways, and
More informationWhat Plans Do I Need for a Building Permit?
What Plans Do I Need for a Building Permit? 6 CITY OF PORTLAND, OREGON - BUREAU OF DEVELOPMENT SERVICES 1900 SW 4th Avenue, Por tland, Oregon 97201 503-823-7300 www.portlandoregon.gov/bds This brochure
More informationExample Plans: Business Signs (Not For Construction)
Plans: Business s Site Plan 220 10 utility easement 120 40 50 Proposed Awning Proposed Freestanding 40 79 20 Street Name Proposed Wall C L N 123 Historic Way Indianapolis, IN 46000 Basic Elements of a
More information2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard
More informationSUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT
SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT SINGLE-FAMILY SITE PLAN INFORMATION PACKET GENERAL INFORMATION This information packet explains how your application for a single-family site plan will
More informationStandard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.
DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard
More informationROUTES: 65 SECTIONS: miles in length. THE FOLLOWING ITEMS AND APPROXIMATE QUANTITIES ARE INVOLVED:
ARKANSAS DEPARTMENT OF TRANSPORTATION CA0801 HWY. 110 - CLINTON (WIDENING) (S) FEDERAL AID PROJECT ACNHPP-0071(31) THE PURPOSE OF THIS PROJECT IS TO WIDEN HIGHWAY 65 IN VAN BUREN COUNTY. THIS PROJECT CONSISTS
More informationKC Water Rules and Regulations For Water Main Extensions and Relocations
KC Water Rules and Regulations For Water Main Extensions and Relocations MAY 2017 NOTE: Changes from 2016 are highlighted in yellow and appear on Pages 5, 8, 10-11, 13, and 15. Additional changes made
More informationWATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL
WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL This summary is not all inclusive of the requirements set forth by the York County Planning & Development Services, York County
More information10010 RECORD DRAWING INFORMATION
SECTION 10000 RECORD DRAWING CHECK LIST All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes, shall submit to the Town of Cary Engineering
More informationEssential Skills: Reading and Interpreting Maps and Plans
Essential Skills: Reading and Interpreting Maps and Plans Prepared for: NEW YORK STATE PLANNING FEDERATION April 14, 2015 Prepared by: BME ASSOCIATES Peter G. Vars, P.E. Stages of Plan Review Concept /
More informationResidential Plot Plans
Residential Plot Plans Planning & Development Services/Building Safety Division 1 Riverfront Plaza Ste. 110 Lawrence, KS 66044 (785)832-7700 Fax (785)832-3110 Email: buildinginspections@lawrenceks.org
More informationACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS
ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS Detailed construction drawings for system extensions shall be prepared for approval with a submittal to the Authority. All construction
More informationTown of Mount Pleasant PRELIMINARY Design Review Submittal Check List June 1, 2014
Town of Mount Pleasant PRELIMINARY Design Review Submittal Check List June 1, 2014 This form is to be completed by either applicant or their representative and submitted with Preliminary Review plans.
More informationEIGHTH AMENDMENT TO THE PARVIN ROAD CORRIDOR TIF PLAN TAX INCREMENT FINANCING PLAN
EIGHTH AMENDMENT TO THE PARVIN ROAD CORRIDOR TIF PLAN TAX INCREMENT FINANCING PLAN I. Introduction The purpose of the Eighth Amendment to the Parvin Road Corridor Tax Increment Financing Plan (hereinafter
More informationREQUIREMENTS. for ENGINEERING SERVICES PUBLIC CONSTRUCTION PROJECTS
REQUIREMENTS for ENGINEERING SERVICES on PUBLIC CONSTRUCTION PROJECTS April, 2007 David W. Johnson Senior Engineer Design & Construction Requirements for Engineering Services on Public Construction Projects
More informationProject Name: County File No.: Checked by: For: Date:
Project Name: County File No.: Checked by: For: Date: Print name Firm or agency Items noted in the checklist shall be considered the minimum amount of information necessary for submission of construction
More informationSection 101. Street Design
Section 101 Street Design This section establishes the uniform policies and procedures for the preparation of street design plans and construction requirements in the City of Irvine. It is not intended
More informationCity of Starkville Development Review Committee Infrastructure Drawings Submittal Checklist for Site Plan Applications
City of Starkville Development Review Committee Infrastructure Drawings Submittal Checklist for Site Plan Applications Please submit ten (10) folded copies of the Infrastructure Drawings along with this
More informationSUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT
Case #: SUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT 171 North Ross Street, Suite 200 Auburn, AL 36830 (334) 501-3000 ~ Fax: (334) 501-7294 Applicant Name: Mailing Address: Email Address:
More information1. Denver Water is not the provider. [C1 Cover] Baseline Response: Revised to show Thornton Water Department as the provider.
Nate Hatleback Project Manager City of Thornton 303 538 7694 Nate.Hatleback@cityofthornton.net Re: Topgolf Review The City of Thornton has provided comments regarding several submittals on June 14 th,
More informationConceptual, Preliminary and Final Site Plan Review in Holladay City
Conceptual, Preliminary and Final Site Plan Review in Holladay City The City of Holladay incorporated in December, 1999 and adopted its own zoning ordinance in May, 2000. All land use decisions are made
More informationPRECISE GRADING PLAN CHECKLIST
PRECISE GRADING PLAN CHECKLIST PUBLIC WORKS DEPARTMENT / ENGINEERING DIVISION 8130 Allison Avenue, La Mesa, CA 91942 Phone: 619. 667.1166 Fax: 619. 667.1380 Grading plans shall address both rough grading
More informationCITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS
CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 002 DRAFTING AND DRAWING STANDARDS SECTION 2.1 INTRODUCTION... 1 (a) Objective...1 (b) Applicability...1 2.2 SUBMITTAL
More informationLegal Description & Site Plan Requirements and Layouts
Legal Description & Site Plan Requirements and Layouts Plot Plan * A plot plan shows the location of a house from an aerial view. * The site plan, also known as a plot or lot plan includes: 1. Site plan
More informationSingle-Family Dwelling Submittal Requirements
Single-Family Dwelling Submittal Requirements The purpose of this guideline is to assist our customers in preparing for plan submittal. The items listed must be included before your plans can be accepted
More informationNOTICE. INFRASTRUCTURE: Currently, the District is responsible for infrastructure in Lakewood Ranch COD 5 including but not limited to the following:
This Instrument prepared by and recording return to: Lakewood Ranch Town Hall 8175 Lakewood Ranch Blvd. Lakewood Ranch, FL 34202 NOTICE DISCLOSURE OF PUBLIC FINANCING AND MAINTENANCE OF IMPROVEMENTS TO
More informationCITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST
CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for
More informationChapter 13 Plan Submittals
Chapter 13 Plan Submittals U30013.DOC 02/01/07 Chapter 13 Plan Submittals Section Topic Page 13.1 General 13.1 13.2 Subdivision Plans 13.1 13.3 Capital Improvement Project Plans 13.12 U30013.DOC 02/01/07
More informationSUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard
More informationDIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS
CITY OF ALBANY DEPARTMENT OF PUBLIC WORKS DIVISION A GENERAL AND DRAFTING ENGINEERING STANDARDS Prepared By PUBLIC WORKS DEPARTMENT ALBANY, OREGON 97321 Telephone: (541) 917-7676 TABLE OF CONTENTS A 1.00
More informationSeptember 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP
CITY OF ANN ARBOR, MICHIGAN Public Services Area / Engineering 301 E. Huron Street, P.O. Box 8647 Ann Arbor, Michigan 48107 Phone (734) 794-6410 Fax (734) 994-1744 Web: www.a2gov.org Printed on recycled
More information