Tratos High Voltage cables

Size: px
Start display at page:

Download "Tratos High Voltage cables"

Transcription

1 March 2013 Tratos High Voltage cables Cables for a moving world

2 Introduction High Voltage Cables Tratos is an international manufacturer and supplier of High & Extra High Voltage cable up to 245 kv. Since 1966, we have entered a new market segment producing high voltage cables up to 220 kv. In collaboration with our suppliers of new generation joints and terminals we are able to supply turnkey solutions incorporating design project management, production, installation and maintenance. Characteristics Advanced technology and construction Flexibility Lightness Strength Low maintenance and simpler accessories Applications Instruments, ignition systems, AC and DC power transmission Typical Usage In apparatus generally short lengths Within buildings or as buried cables in an industrial plant or for power distribution generally variable lengths As submarine cables under the ocean for power transmission as long as required 2

3 Introduction Cable construction Conductor consists of stranded Aluminium or soft drawn copper produced by two technologies: Circular Compacted (One or multi layers of stranded wires are assembled together to form a circular compacted conductor), Segmental Conductor (Five segments of compacted conductor in triangle shape of 72 degree are assembled together with separation of non metallic tapes to reduce the skin effect which reduce the AC conductor resistance. Segmental conductors are applied for conductor cross sectional area of 1000 mm2 and above). Swelling powder or water blocking tapes can be applied between the conductor strands to block the ingress of water inside the cable conductor (if required). An extruded layer of cross linkable semi conducting to reduce and control the electrical stress beneath the insulation layer of cross linked polyethylene (XLPE). The semi conducting layer shall be firmly bonded to the inner layer of the insulation. An extruded layer of cross linked polyethylene (XLPE) of high grad is extruded in dry cooling and curing continuous vulcani sation line. The thickness of insulation should be calculated as per the operating voltage, impulse voltage and expected cable life which should be verified by carrying out type tests as per the applicable standards. An extruded layer of cross linkable semi conducting is applied over the insulation layer to insure that the electric stress is homogenous around the insulated core. The semi conducting layer shall be firmly bonded to the outer layer of the insulation. Conductor screen, insulation and insulation screen are applied simultaneously in one process (triple extrusion process) to insure that all extruded layers are firmly bonded together. One or multi layers of metallic screen / sheath such as copper wires, lead, aluminum, etc. shall be applied as a return path of earth fault current. Metallic sheaths may be used for water blocking protection and mechanical protection. An extruded layer of PVC, PE (HDPE, LDPE, MDPE) shall be applied over the metallic layers for protection against chemical reaction, mechanical and electrical protection. Extruded semi conductive layer or graphite coating shall be applied over the outer sheath for testing purpose. 3

4 Introduction Faraday Cage Test Measuring 24m x 16m and standing at 14m high the cage enables Tratos to effectively administer AC Resonant Tests on site, allowing testing of up to 220kV of nominal voltage cables and up to 20km of medium voltage cable. The facility incorporates a new innovative locking system to ensure perfect shielding from any sort of external interference. Inside are sophisticated tools for testing and an adjustable high voltage reactor which, together with the exciter and the regulator, comprise the heart of the system. 4

5 Introduction Faraday Cage Test The reactor is insulated in oil. Its upper part includes space for oil expansion and it offers 12MW of resonance power, allowing three taps of 350kV, 150kV and 70kV. The exciter section is mounted in a separate oil-filled steel tank and contains a single phase, step-up transformer which supplies the AC voltage required for the resonant circuit. The regulator provides an adjustable input voltage to the exciter and controls the input voltage of the reactor. This sophisticated equipment can detect even very low levels of picocoulombs immunity to electrical noise, and resistance to vibration and impact. This allows incredibly precise measurements to be recorded, ensuring that Tratos meets industry standard ISO 9001, that Tratos is approved by BASEC and that the company s own exceptional standards of quality are granted. 5

6 Key Customers 6

7 Quality Approvals Facilities 7

8 Case Studies

9 Case studies Emirates Steel Industries Company: Danieli Type: HV cable 72 kv Tratos signed a contract with Italy's Danieli Corporation for the expansion of the Emirates Steel Industries (ESI) steel manufacturing factory located at Abu Dhabi's prestigious industrial city ICAD several kilometres of HV 72 kv cable have been supplied for this project. 9

10 Case studies Kent PHK Ltd Company: Kent PHK Ltd. Type: HV cable 66 kv In 2007, Tratos supplied Kent PHK Ltd with HV cables of 66 kv for railways. 10

11 Case studies Project Name: Altahullion - County Londonderry, Northern Ireland - Onshore wind farm Company: RES/B9 Energy Services Developed by: RES/B9 Energy Services Operator: RES Owner: RES Cable: HV cable and fibres Installation date: 2003 Commissioning: 2003 Description: Wind firm 26 MW - 20 turbines Siemens SWT (power 1300 kw, diameter 62 m) - Total nominal power: 26 MW Altahullion is situated near Dungiven, County Londonderry and is owned by RES. It was designed and built by RES using local contractors and commissioned in Altahullion's 20 turbines can generate up to 26MW. Electricity from the wind farm is sold to Belfast based Energia who supply hospitals, schools and Northern Ireland businesses. The public can visit the site by following the signs from the A6 Dungiven to Derry road. There is car parking, an information board and a special path up to the visitor turbine. 11

12 Case studies Project Name: Altahullion II - County Londonderry, Northern Ireland - Onshore wind farm Company: RES Developed by: RES Operator: RES Owner: RES Cable: HV cable and fibres Installation date: 2007 Commissioning: 2007 Description: Wind firm 11.7 MW - 9 turbines Siemens SWT (power 1300 kw, diameter 62 m) - Total nominal power: 11.7 MW The nine turbine extension to Altahullion Wind Farm, near Dungiven County Londonderry, was commissioned in The nine new turbines provide an additional 11.7 megawatts of power. The extension takes the total number of turbines at Altahullion to 29, with a total power capacity of 37.7 megawatts. The extension was developed and built by RES, with the help of local contractors. 12

13 High Voltage Cables

14 High Voltage Cables TRATOS HV - 38/66 kv-(72.5 kv) CU/XLPE/AT/HDPE Construction Conductor: stranded circular or segmental compacted copper Conductor screen: semi-conducting layer Insulation: XLPE Insulation screen: non metallic - semi-conducting layer and copper wire as metallic Tape: non-conductive water blocking Tape: copolymer aluminium tape Outer sheath: HDPE sheathed with graphite coating or extruded semi-conducting layer Standard colour: black Standards Design and Tested: IEC 60228, and

15 High Voltage Cables TRATOS HV - 38/66 kv-(72.5 kv) CU/XLPE/PB/HDPE Construction Conductor: stranded circular or segmantal compacted copper Conductor screen: semi-conducting layer Insulation: XLPE Insulation screen: non metallic - semi-conducting layer Tape: non-conductive water blocking Sheath: lead Outer sheath: HDPE sheathed with graphite coating or extruded semi-conducting layer Standard colour: black Standards Design and Tested: IEC 60228, and

16 High Voltage Cables TRATOS HV - 76/132 kv-(145 kv) CU/XLPE/AT/HDPE Construction Conductor: stranded circular or segmantal compacted copper Conductor screen: semi-conducting layer Insulation: XLPE Insulation screen: non metallic - semi-conducting layer Screen: copper wire as metallic Tape: semi-conductive water blocking Tape: copolymer aluminum tape Outer sheath: HDPE sheathed with graphite coating or extruded semi-conducting layer Standard colour: black Standards Design and Tested: IEC 60228, and

17 High Voltage Cables TRATOS HV - 76/132 kv-(145 kv) CU/XLPE/PB/HDPE Construction Conductor: stranded circular or segmantal compacted copper Conductor screen: semi-conducting layer Insulation: XLPE Insulation screen: non metallic - semi-conducting layer Tape: semi-conductive water blocking Sheath: lead Outer sheath: HDPE sheathed with graphite coating or extruded semi-conducting layer Standard colour: black Standards Design and Tested: IEC 60228, and

18 Tratos on demand Cables Tailor Made Our Cables Tailor Made" service can offer custom design and built solutions to the most demanding of circumstances. In conjunction with our clients Tratos can offer you: Variety of lengths Large overall diameter (above standard products) Cable designs Bespoke cables Environmentally specific cables (mud, chemicals, UV, water, oil, radiation) Case Study Tratos has manufactured and supplied Superconducting conductors to ITER (International Thermonuclear Experimental Reactor), an international nuclear fusion research and engineering project, which is currently building the world's largest experimental tokamak nuclear fusion reactor at the Cadarache facility in the south of France. 18

19 Tratos Group Cables for a moving world

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

REPORT OF PERFORMANCE TIC

REPORT OF PERFORMANCE TIC REPORT OF PERFORMANCE TIC 1580-13 OBJECT TYPE Three-core power cable 18/30(36) kv, 3x500 mm2, 2XWY(P)-FR XLPE Rated voltage, U 0/U (U m) 18/30 (36) kv Conductor material Cu Conductor cross-section 3x500

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv HV SYSTEMS Prysmian HV Systems Product Range 66kV & 132 kv Prysmian HV Product Range Version: 06/10 The History of Cables 66kV Copper Conductor XLPE Insulated Cables Prysmian Cables & Systmes Ltd is part

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

Tests on Extruded Cables

Tests on Extruded Cables Tests on Extruded Cables Pierre Argaut Chairman of CIGRE SC B1 October 26 th, 2011 At least, once in your life, you have heard these words: Development Tests Long-term Tests Prequalification Tests Extension

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature

More information

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv DRAFT SOUTH AFRICAN STANDARD (DSS): PUBLIC ENQUIRY STAGE Document number: 66/1339/4 Reference: SANS 1339 Date of circulation: 2009-12-08 Closing date: 2010-02-08 Number and title: SANS 1339:2010 Electric

More information

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE 09-1026 TYPE TEST CERTIFICATE OF COMPLETE TYPE TEST OBJECT single-core power cable TYPE 76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE Rated voltage, U o /U (U m ) 76/132 (145) kv Conductor material

More information

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems Summary for Call for Nominations 1. Background and scope ITER will be the world's largest experimental facility to demonstrate

More information

Testing Manual for Electrical Equipment

Testing Manual for Electrical Equipment EPPM, Singapore, 20-21 Sep 2011 Abstract Testing Manual for Electrical Equipment Nahed Al-Hajeri 1 and Anantha Madhavan 2 Quality Assurance (QA) refers to a program for the systematic monitoring and evaluation

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS) TENDER DOCUMENT NIT No. DLI/C&E/WI-665/535R FOR Tender for Supply of 3CX185 mm2, 11 KV (UE) grade, Power Cable for Augmentation of Raw Material Handling Receipt and Handling Facilities with new OHP Part

More information

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS 1.0 SCOPE 2.0 BONDING METHODS 2.1 Introduction 2.2 Design 2.3 Single-Point Bonding 2.4 Cross Bonding 2.5 Sheath Sectionalizing Joints 2.6 Sheath Standing Voltage 2.7 Sheath Voltage at Through Fault 2.8

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

EDS KV TRIPLEX CABLE RATING

EDS KV TRIPLEX CABLE RATING Document Number: EDS 02-0027 Network(s): Summary: EPN, LPN, SPN ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE RATING This engineering design standard provides the cable ratings and important

More information

This Certificate consists of 75 pages in total.

This Certificate consists of 75 pages in total. Object Heat shrinkable indoor termination 1086-16 Type MZDNK-3-15-C Rated voltage, U 0 /U (U m ) 8,7/15 (17,5) kv Conductor material Cu Conductor cross-section 3 x 185 mm 2 Insulation material XLPE Manufacturer

More information

EDS KV SINGLE CORE XLPE CABLES

EDS KV SINGLE CORE XLPE CABLES THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0034 ENGINEERING DESIGN STANDARD EDS 02-0034 33KV SINGLE CORE XLPE CABLES Network(s): EPN, LPN,

More information

Addison Medium Voltage Cables

Addison Medium Voltage Cables Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

Pulse Cable for TESLA Modulators Hans-Jörg Eckoldt DESY TESLA

Pulse Cable for TESLA Modulators Hans-Jörg Eckoldt DESY TESLA Pulse Cable for TESLA Modulators Hans-Jörg Eckoldt DESY TESLA 2000-35 1 Introduction... 3 2 Demands for the cable... 3 3 Cable construction... 3 4 Simulation results... 4 5 Installation... 7 6 Cooling...

More information

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

شركة الوقت للكهرباء والمقاوالت ذ.م.م. CONTRACTING COMPANY W.L.L. is a leading corporate in the United Arab Emirates offering quality services in the field of High Voltage Electrical work 400, 132 & 33 kv and Medium Voltage Power Distribution

More information

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv Israel Electric Corporation Ltd. - Customer Division - National Network Unit Issued date: February 2018 THE ISRAEL ELECTRIC CORPORATION LTD. National Network Unit Specification No. NPS - 361 for Single

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

CAST RESIN DRY TRANSFORMER

CAST RESIN DRY TRANSFORMER CAST RESIN DRY TRANSFORMER Majority owned subsidiary company of ELETTROMECCANICA COLOMBO s.a.s., Italy Elettromeccanica India Elettromeccanica India Pvt Ltd (EIPL) is a joint-venture company with Elettromeccanica,

More information

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor

More information

EDS LV WAVEFORM MAINS CABLE RATINGS

EDS LV WAVEFORM MAINS CABLE RATINGS Document Number: EDS 02-0033 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 02-0033 LV WAVEFORM MAINS CABLE RATINGS EPN, LPN, SPN This standard details the technical and practical information required

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information

CLEAN ENERGY Wind energy cables

CLEAN ENERGY Wind energy cables CLEAN ENERGY Wind energy cables 1 Table of Contents TELE-FONIKA KABLE 4 PRODUCTION POTENTIAL 5 CLEAN ENERGY 6 DESCRIPTION OF PICTOGRAMS USED IN CATALOGUE 7 MEDIUM VOLTAGE CABLES 8 MEDIUM VOLTAGE XLPE POWER

More information

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested

More information

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid. 1. Scope This specification defines the methods, the procedures and the requirements to verify the cables manufactured according to I.E.C. Specifications NPS361. 2. Standards All the standards referred

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60287-1-1 Edition 1.2 2001-11 Edition 1:1994 consolidated with amendments 1:1995 and 2:2001 Electric cables Calculation of the current rating Part 1-1: Current rating equations

More information

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES 3.1 Single-Core Copper Wire Screened Polymeric Cables 3.1.1 Removing the Outer Sheath Clean and abrade the outer sheath with an approved abrasive paper for

More information

15 years of experience

15 years of experience Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since

More information

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;

More information

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables 21, rue d Artois, F-75008 PARIS AUCKLAND 2013 http : //www.cigre.org Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables Michael Krüger, Rene Hummel, Stefan Böhler, OMICRON Austria

More information

HV AC TESTING OF SUPER-LONG CABLES

HV AC TESTING OF SUPER-LONG CABLES HV AC TESTING OF SUPER-LONG CABLES Stefan SCHIERIG, (Germany), schierig@highvolt.de Peter COORS, (Germany), coors@highvolt.de Wolfgang HAUSCHILD, IEC, CIGRE, (Germany), hauschild@highvolt.de ABSTRACT The

More information

EXCELLENT ELECTRICAL PERFORMANCES

EXCELLENT ELECTRICAL PERFORMANCES 50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations Version: 3.1 Date of Issue: September 2016 Page: 1 of 21 NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations 1. Purpose The purpose of this document is to detail the technical requirements

More information

TRANSFORMER TECHNOLOGY GPT

TRANSFORMER TECHNOLOGY GPT Core-Form TRANSFORMER TECHNOLOGY GlobalPT Corporation performs research and engineering developments and co-ordination of works of technical partners in the field of technological progress and commercial

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

Testing 320 kv HVDC XLPE Cable System

Testing 320 kv HVDC XLPE Cable System Testing 320 kv HVDC XLPE Cable System H. He, W. Sloot DNV GL, KEMA Laboratories Arnhem, The Netherlands Abstract Two unique test requirements in testing of a high- voltage direct- current (HVDC) cable

More information

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N S C I E N C E P A S S I O N T E C H N O L O G Y HVDC Transmission Michael Muhr Graz University of Technology Austria www.tugraz.at 1 Definition HV High Voltage AC Voltage > 60kV 220kV DC Voltage > 60kV

More information

HIGH PRESSURE MOULDING TECHNOLOGY

HIGH PRESSURE MOULDING TECHNOLOGY HIGH PRESSURE MOULDING TECHNOLOGY Romuald Lemaitre, Pierre Gaillard, Franck Tortey, Paul Woodward franck.tortey@alcatel-lucent.fr Alcatel - Lucent, 536 Quai de La Loire 62100 Calais Abstract: The Optical

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: All ENGINEERING COMMISSIONING PROCEDURE ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing of new and

More information

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems

More information

P Low Voltage Catalogue Cables Australia Powering your Project

P Low Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high

More information

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED Dial : (033)2677-5835 & 2667-8358 Tele Fax : (033)2667-8358 Manufacturer of Dry Type Transformers E-mail : unimag111@gmail.com Office & Factory : 26/5, Sarat Chatterjee Road, Howrah 711 104, West Bengal,

More information

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Efacec work every day to anticipate solutions for a sustainable world in the new energy era. Transformers Efacec is the largest industrial portuguese company of the electric and electromechanical sector developing high technology products, solutions and systems used every day by millions of people

More information

A6.6 9 th International Conference on Insulated Power Cables A6.6

A6.6 9 th International Conference on Insulated Power Cables A6.6 Development Process of extruded HVDC cable systems Dominik HÄRING, Gero SCHRÖDER, Andreas WEINLEIN, Axel BOSSMANN Südkabel GmbH, (Germany) dominik.haering@suedkabel.com, gero.schroeder@suedkabel.com, andreas.weinlein@suedkabel.com,

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70 Name : Roll No. :.... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/2011-12 2011 POWER SYSTEM-I Time Allotted : 3 Hours Full Marks : 70 The figures in the margin indicate full marks. Candidates

More information

AORC Technical meeting 2014

AORC Technical meeting 2014 AORC Technical meeting 2014 http : //www.cigre.org B1-1110 Development of ±160 kv XLPE Cable and its Application to the World s First Three-terminal VSC HVDC System in China Lin-jie Zhao, Hong Rao, Xiao-lin

More information

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another. TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power

More information

Notes 3 Explanatory Information 4-10

Notes 3 Explanatory Information 4-10 Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum

More information

CERTIFICATE OF CONFORMANCE

CERTIFICATE OF CONFORMANCE CERTIFICATE OF CONFORMANCE This is to confirm that Honeywell Airports Business have verified Tinned Copper Braided Screened Primary Cable supplied by PT Jembo Cable Company Tbk (Indonesia) for airfield

More information

Marshall Tufflex. Cable Management. Steel Trunking Systems

Marshall Tufflex.  Cable Management. Steel Trunking Systems Marshall Tufflex Cable Management www.marshall-tufflex.com Steel Trunking Systems Steel Trunking Systems from Marshall Tufflex Steel perimeter trunking systems from Marshall-Tufflex Steel has a mechanical

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

Critical Conductor Temperatures in Submarine Cables Equipped with Protection Pipes

Critical Conductor Temperatures in Submarine Cables Equipped with Protection Pipes 24 th Nordic Insulation Symposium on Materials, Components and Diagnostics 128 Critical Conductor Temperatures in Submarine Cables Equipped with Protection Pipes Rógvi Østerø, Joachim Holbøll Technical

More information

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES 1 Date:19.09.2013/08.01.2014 TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND 1.0 SCOPE: CABLES 1.1 The scope of this specification covers the design, manufacture, stage inspection at works,

More information

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured) WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

DESIGN OF A 45 CIRCUIT DUCT BANK

DESIGN OF A 45 CIRCUIT DUCT BANK DESIGN OF A 45 CIRCUIT DUCT BANK Mark COATES, ERA Technology Ltd, (UK), mark.coates@era.co.uk Liam G O SULLIVAN, EDF Energy Networks, (UK), liam.o sullivan@edfenergy.com ABSTRACT Bankside power station

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE EPN, LPN, SPN ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing

More information

Assuring the Reliability of Critical Power Cable Systems

Assuring the Reliability of Critical Power Cable Systems Assuring the Reliability of Critical Power Cable Systems Presented by: Benjamin Lanz Manager of Application Engineering IMCORP Power Cable Reliability Consulting & Diagnostics Some of the technologies

More information

MULTIMEDIA & DATA TRANSMISSION

MULTIMEDIA & DATA TRANSMISSION NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling

More information

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider Shunt Reactors Global Top Energy, Machinery & Plant Solution Provider Our Business Brief introduction of Hyosung Power & Industrial Systems PG While Hyosung is an established name for world-class electrical

More information

TMC Transformers TMC

TMC Transformers TMC TMC Product & Technology Presentation Cast Resin Transformer (CRT) History Cast resin transformers first appeared in Germany during the 1960s. This new style of dry type transformer was developed with

More information

Umbilicals and Subsea Power Cables Excellence in Connecting Subsea EWEA

Umbilicals and Subsea Power Cables Excellence in Connecting Subsea EWEA Umbilicals and Subsea Power Cables Excellence in Connecting Subsea EWEA Control and Power Umbilicals The control umbilical consists of hydraulic lines used for transfer of chemicals and fluids. In addition,

More information

Market Survey. Technical Description. Supply of Medium Voltage Pulse Forming System for Klystron Modulators

Market Survey. Technical Description. Supply of Medium Voltage Pulse Forming System for Klystron Modulators EDMS No. 1972158 CLIC Drive Beam Klystron Modulator Group Code: TE-EPC Medium Voltage Pulse Forming System for CLIC R&D Market Survey Technical Description Supply of Medium Voltage Pulse Forming System

More information

This is a preview - click here to buy the full publication. IEC 2006 Copyright - all rights reserved

This is a preview - click here to buy the full publication. IEC 2006 Copyright - all rights reserved INTERNATIONAL STANDARD IEC 60287-1-1 Second edition 2006-12 Electric cables Calculation of the current rating Part 1-1: Current rating equations (100 % load factor) and calculation of losses General IEC

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

Diagnostic testing of cast resin transformers

Diagnostic testing of cast resin transformers Paper of the Month Diagnostic testing of cast resin transformers Author Michael Krüger, OMICRON, Austria michael.krueger@omiconenergy.com Christoph Engelen, OMICRON, Austria christoph.engelen@omicronenergy.com

More information

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers SPECIFICATION GUIDE ABB VACUUM CAST COIL DRY TRANFORMERS CONTENTS 1. General 1.1. Codes and standards 1.2. Service conditions 1.3. System characteristics 1.4. Documentation 2. Design and construction 2.1.

More information

Premoulded cable joint SMPGB

Premoulded cable joint SMPGB Premoulded cable joint SMPGB 362-420 Premoulded for safe and easy installation Active pressure Reliable Joint bodies routinetested according to IEC before delivery Bolt connector technology Compact joint

More information

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By : Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg

More information

3.7 Grounding Design for EAST Superconducting Tokamak

3.7 Grounding Design for EAST Superconducting Tokamak 3.7 Design for EAST Superconducting Tokamak LIU Zhengzhi 3.7.1 Introduction system is a relevant part of the layout of Tokamak. It is important and indispensable for the system reliability and safety on

More information

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

EI HIGH VOLTAGE INSULATION TESTING POLICY

EI HIGH VOLTAGE INSULATION TESTING POLICY Network(s): Summary: ENGINEERING INSTRUCTION EI 09-0001 HIGH VOLTAGE INSULATION TESTING POLICY EPN, LPN, SPN This engineering instruction details the policy for the on-site insulation testing of new and

More information

Power transformers for Network, Rectifiers, Furnace

Power transformers for Network, Rectifiers, Furnace E N G L I S H OTN, OTR, OTF Transformers Power transformers for Network, Rectifiers, Furnace TTR TTO OTN, OTR, OTF reactors TTH OTN, OTR, OTF Transformers Technology Design Our designers experience combined

More information

DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES

DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES Heiner Ottersberg 1 NSW The Company Over 100 Years Experience in Cable Technology 1899 NSW (Norddeutsche Seekabelwerke) is founded by the

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices

More information

Introduction. Centrado leading-edge transformer. Introduction

Introduction. Centrado leading-edge transformer. Introduction Introduction Centrado leading-edge transformer products are designed to optimize safety and produced to deliver a great electrical power experience and solution - for factory, infrastructure, home industry,

More information

MATEFU Insulation co-ordination and high voltage testing of fusion magnets

MATEFU Insulation co-ordination and high voltage testing of fusion magnets Stefan Fink: MATEFU Insulation co-ordination and high voltage testing of fusion magnets Le Chateau CEA Cadarache, France April 7th, 29 Insulation co-ordination Some principle considerations of HV testing

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

Hendrix Tap, Tie & Ground Wire

Hendrix Tap, Tie & Ground Wire Hendrix Tap, Tie & Ground Wire MADE IN U.S.A. 53 Old Wilton Road Milford, NH 03055-3119 603-673-2040 www.marmonutility.com A Marmon Wire & Cable/Berkshire Hathaway Company Tap Wire Description Hendrix

More information