Camur II Anode Ladder Quick

Size: px
Start display at page:

Download "Camur II Anode Ladder Quick"

Transcription

1 Camur II Anode Ladder Quick 1 For automatic monitoring of Anode Ladder and Drill Core Anode 1 sensors Description The Camur II Anode Ladder node monitors automatically LPR, ZRA, resistance, potential and temperature. The inputs are galvanically separated from the bus side. Technical data Inputs Voltage 7 Current 7 AC resistance 7 Temperature 1 (Pt1000) Temp. coefficient 0,009 % / C Noise ± 1 division Impedance > 50 MΩ Sampling interval 1 s Polarization output (LPR) Range ± 2.4 V Resolution 0.1 mv Accuracy % Resistance measurement signals Vosc Rout Range 1 1 V 220 Ω (below 500 Ω: 0.5 V / 220 Ω ) Range 2 1 V 220 Ω Range 3 1 V 220 Ω Range 4 1 V 220 Ω Frequency of 1kHz Power in Power consumption Dimensions (WxHxD) Weight VDC V 64 x 82 x 34 mm 125 g 1 Sensortec GmbH Page 1 of 5

2 Voltage Current AC resistance Temperature Range 1 ± 2.4 VDC ± 5 madc Ω C Resolution 0.1 mv 1 μa 1 Ω 0.01 C Accuracy 0.2 mv 1 μa 1 % ± 0.1 C Range 2 ± 400 μa 2-20 k Ω - Resolution μa 1 Ω - Accuracy μa 1 % - Range 3 - ± 40 μa k Ω - Resolution μa 10 Ω u - Accuracy μa 1 % - Range M Ω - Resolution Ω - Accuracy % - (5% below 1 MΩ) Connectors Bus Double set of screw terminals in the node box. (+, -, H, L) Input / output A1 - A6 Anodes (working electrodes) 1-6 RC Rebar connection C Cathode (counter electrode) RE Reference electrode P1+ Supply voltage for Pt1000 P2- Supply voltage for Pt1000 P1 Input for Pt1000 P2 Input for Pt1000 Note! For two-wire Pt1000 sensors, connect P1+ with P1 and P2- with P2. The analog inputs are not galvanically separated from each other. Recording types Page 2 of 5

3 The Anode Ladder node supports recording types Monitor, Monitor Extended and LPR in Camur II software. Outputs from measurements in standard format reports a list of the measurements of each sensor in the format: [sensor name]-[value type], one column for each combination. Measurements that belong to the same sample interval are collected in one row. Measurement reports Monitor Value / type Unit Measurement I 1 ma Current between A1 and C I 2 ma Current between A2 and C I 3 ma Current between A3 and C I 4 ma Current between A4 and C I 5 ma Current between A5 and C I 6 ma Current between A6 and C I 7 ma Current between RC and C R 1 k Ω Resistance between A1 and A2 R 2 k Ω Resistance between A2 and A3 R 3 k Ω Resistance between A3 and A4 R 4 k Ω Resistance between A4 and A5 R 5 k Ω Resistance between A5 and A6 R 6 k Ω Resistance between A6 and RC R 7 k Ω Resistance between RC and C T C Temperature U 1 mv Potential between A1 and RE U 2 mv Potential between A2 and RE U 3 mv Potential between A3 and RE U 4 mv Potential between A4 and RE U 5 mv Potential between A5 and RE Page 3 of 5

4 U 6 mv Potential between A6 and RE U 7 mv Potential between RC and RE Monitor Extended The same as in Monitor plus LPR result calculation Value/ type Unit Measurement C1 I ma Calculated corrosion current at A1 C2 I ma Calculated corrosion current at A2 C3 I ma Calculated corrosion current at A3 C4 I ma Calculated corrosion current at A4 C5 I ma Calculated corrosion current at A5 C6 I ma Calculated corrosion current at A6 C7 I ma Calculated corrosion current at RC LPR measurements C1-V mv Potential between A1 and RE C1-I ma Current between A1 and C C2-V mv Potential between A2 and RE C2-I ma Current between A2 and C C3-V mv Potential between A3 and RE C3-I ma Current between A3 and C C4-V mv Potential between A4 and RE C4-I ma Current between A4 and C C5-V mv Potential between A5 and RE C5-I ma Current between A5 and C C6-V mv Potential between A6 and RE C6-I ma Current between A6 and C Page 4 of 5

5 C7-V mv Potential between RC and RE C7-I ma Current between RC and C LPR results Value/ type Unit Measurement C1I ma Calculated corrosion current at A1 C1S ma Standard deviation for corrosion current at A1 C2I ma Calculated corrosion current at A2 C2S ma Standard deviation for corrosion current at A2 C3I ma Calculated corrosion current at A3 C3S ma Standard deviation for corrosion current at A3 C4I ma Calculated corrosion current at A4 C4S ma Standard deviation for corrosion current at A4 C5I ma Calculated corrosion current at A5 C5S ma Standard deviation for corrosion current at A5 C6I ma Calculated corrosion current at A6 C6S ma Standard deviation for corrosion current at A6 C7I ma Calculated corrosion current at RC C7S ma Standard deviation for corrosion current at RC Page 5 of 5

AI Analogue Input Module (open < 2.8 ma)

AI Analogue Input Module (open < 2.8 ma) General Specifications GS48C17Z02-00E-N -02 Analogue Input Module (open < 2.8 ma) GENERAL Figure 1 This Analogue Input module, or trip amplifier, contains two circuits and can be utilized for various applications.

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

USB-TEMP and TC Series USB-Based Temperature Measurement Devices USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*

More information

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A slimline RS / EC Universal Measurement System Q.raxx A107-16 slimline RS / EC Universal Measurement System The Q.raxx slimline product is based on the standardised 19 technology, one rack unit (1 U) and is designed for measurements with a high level

More information

DEA 115, Digital Input/Output Modules

DEA 115, Digital Input/Output Modules Catalog 12 Input/Output Modules for S5 115 DEA 115, Digital Input/Output Modules Digital input/output module The digital input modules from the Systeme Helmholz GmbH convert the external binary signals

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

Components Signal Conditioning For Your Computer Instruments Standard Models

Components Signal Conditioning For Your Computer Instruments Standard Models EPAD2/CPAD2 Modules Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement CAN and RS-485 Modules EPAD2/CPAD2 Modules The EPAD2 and CPAD2 series are multichannel

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A... Electronics & Software Kistler LabAmp Charge Amplifier and Data Acquisition Unit for Dynamic Measurements This universal laboratory charge amplifier can be used wherever dynamic signals 1) of mechanical

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

Q.raxx A slimline RS / EC

Q.raxx A slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

DC Resistance Meters 2840 Series

DC Resistance Meters 2840 Series Data Sheet DC Meters Touch screen to zoom, select, and enter values The DC resistance meters feature high accuracy and resolution measurements in the milliohm range. Both meters are ideally suited for

More information

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status 06/03/0 panelmeter_gb.doc page subject to alterations; errs including printer s errs Digital panel meter Direct voltage

More information

Q.raxx A101-8 slimline RS / EC

Q.raxx A101-8 slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack mount unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field

More information

DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges

DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges ENERGY METERS 099 0 0 0 Overview of product range General overview Product selection guide by functions by applications Info & advice Keeping up with current changes µdigi and µdigi ranges x8 mm or 8x9

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Force and strain sensors. Measure. Test. Control. Edition 2016

Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key

More information

Measurement and Instrumentation

Measurement and Instrumentation POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Overview of ranges Selection guide Info & advice Economical range for industrial use μdigi1 - μdigi2 ranges Programmable range for universal

More information

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status /0/04 panelmeter6x4_gb.doc page subject to alterations; errs including printer s errs 6x4 Digital panel meter Direct

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

hvbase-n Negative High Voltage Generator and Voltage Divider for 10-stage PMT

hvbase-n Negative High Voltage Generator and Voltage Divider for 10-stage PMT and Voltage Divider for 10-stage PMT hvbase-n The is a combined negative high voltage generator and voltage divider for 10-stage photomultiplier tubes (PMT). It supports digital or analog high-voltage

More information

Homework Assignment 01

Homework Assignment 01 Homework Assignment 01 In this homework set students review some basic circuit analysis techniques, as well as review how to analyze ideal op-amp circuits. Numerical answers must be supplied using engineering

More information

Modicon Momentum automation platform 0

Modicon Momentum automation platform 0 Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,

More information

Exercise 2: Demodulation (Quadrature Detector)

Exercise 2: Demodulation (Quadrature Detector) Analog Communications Angle Modulation and Demodulation Exercise 2: Demodulation (Quadrature Detector) EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain demodulation

More information

SILICon IrrADIAnCe SenSor

SILICon IrrADIAnCe SenSor Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic

More information

DS 6000 Specifications

DS 6000 Specifications DS 6000 Specifications All the specifications are guaranteed except the parameters marked with Typical and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.

More information

Kistler LabAmp for DynoWare

Kistler LabAmp for DynoWare Electronics & Software Kistler LabAmp for DynoWare Charge Amplifier and Data Acquisition for Multicomponent Force Measurement This instrument is ideal for multicomponent force-torque measurement with piezoelectric

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface EPAD & CPAD Modules EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series are multichannel modules and combine analog signal conditioning and A/D converter in an extremely

More information

500mA Laser Diode Controller

500mA Laser Diode Controller IP500 500mA Laser Diode Controller Operating Manual THORLABS, Inc. Ph: (973) 579-7227 435 Route 206N Fax: (973) 300-3600 Newton, NJ 07860 USA www.thorlabs.com Table of Contents TABLE OF FIGURES 1 OVERVIEW

More information

TxBlock-USB Transmitter

TxBlock-USB Transmitter Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is

More information

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page: http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com Operating instructions RPM8000-OBD2

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

Lock-In-Amplifier Module

Lock-In-Amplifier Module Features BNC Connectors for Input and Output Signals Rugged Aluminium Housing Single Phase Detection with X Output Working Frequency 5 Hz... 10 khz, Digital Phase Shifter 0... 360 Parameter Control by

More information

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions RIGOL Data Sheet Product Overview DM3058/DM3058E [1] is a digital multimeter designed with 5 ½ digits readings resolution and dual-display especially fitting to the needs of high-precision, multifunction

More information

DA-Type Socket Assemblies

DA-Type Socket Assemblies DA-Type Socket Assemblies Socket Assemblies with Transimpedance Amplifier (DA Type) DA type socket assemblies contain an active voltage-divider circuit and an amplifier that converts high impedance current

More information

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface EPAD & CPAD Modules Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series

More information

AT432 Low Voltage Adjustable Shunt Regulator

AT432 Low Voltage Adjustable Shunt Regulator FEATURES DESCRIPTION Low voltage operation (down to 1.24V) Wide operating current range 80µA to 100mA 0.2Ω Typical output impedance Voltage reference tolerance 1% for B series and 0.5% for A series Pin-to-Pin

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Universal Dummy Cell 2. Operator's Manual

Universal Dummy Cell 2. Operator's Manual Universal Dummy Cell 2 Operator's Manual Copyright 2003, Gamry Instruments, Inc. All rights reserved. Printed in the USA. Revision 1.0 May 5, 2003 Copyrights and Trademarks UDC2 Universal Dummy Cell 2

More information

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing

More information

Integrated Servo Motor UCS57

Integrated Servo Motor UCS57 Integrated Servo Motor Introduction is a new generation of high performance digital integrated servo drive motor, which is a series of low voltage AC servo products integrated with AC servo motor and drive

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

VariTrans P V. Safe and Sound.

VariTrans P V. Safe and Sound. 1000 V. Safe and Sound. VariTrans P 29000 Compact high-voltage isolation amplifiers with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection. Isolation Amplifiers

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

Solid State Pressure Sensors D8M

Solid State Pressure Sensors D8M Solid State Pressure Sensors D8M Solid State Pressure Sensors with Analog, Pulse or Frequency Outputs Compact housing measures 30L x 30W x 12.4H mm. Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing

More information

Differential charge amplifier

Differential charge amplifier Electronics Differential charge amplifier Type 5181A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure

More information

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

E Charge-controlled amplifier module

E Charge-controlled amplifier module Technical Note E-506.10 Charge-controlled amplifier module Description... 1 Charge-controlled piezo operation... 1 Position servo-control operation... 1 CE conformity... 2 Safety notes... 3 Operating controls...

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014 OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS VERSION 1.2 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230;

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC Selection Guide PAD Series Modules Multi channel Low bandwidth - for static signals Isolation Digital output (RS-485) Exchangeable For DEWETRON systems with built-in DAQ rack Module # CH Input type Ranges

More information

DIGITAL MULTIMETER AX-588B

DIGITAL MULTIMETER AX-588B DIGITAL MULTIMETER AX-588B OPERATION MANUAL 1. Sumary His series product is a stable and battery-driven 3 ½ digital multimeter with high reliability. It adopts LCD screen with character height of 28mm;

More information

Shenzhen Tuofeng Semiconductor Technology Co., Ltd

Shenzhen Tuofeng Semiconductor Technology Co., Ltd TF PROGRAMMABLE PRECISION REFERENCES The is three-terminal adjustable shunt regulator with specified termal stability. The output voltage may be set to any value between (Approx. 2.5V) and 36V with two

More information

RTD Input Module. Product Specifications and Installation Data 1 DESCRIPTION 2 INSTALLATION

RTD Input Module. Product Specifications and Installation Data 1 DESCRIPTION 2 INSTALLATION RTD Input Module Product Specifications and Installation Data 1 DESCRIPTION The HE693RTD720 Input Modules allow RTD temperature sensors to be directly connected to the PLC without external signal processing

More information

User Manual Digital Multimeter

User Manual Digital Multimeter User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Product Information Features System Sources

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

BATTERY HiTESTER BT3563, BT3562, 3561

BATTERY HiTESTER BT3563, BT3562, 3561 BATTERY HiTESTER BT3563, BT3562, 3561 Simultaneous high-speed measurement of internal resistance and battery voltage From large-cell to high-voltage battery testing - HIOKI is The Choice The BT3563, BT3562,

More information

Analog Modules AS-i IP20

Analog Modules AS-i IP20 (Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage

More information

AT431 Adjustable Precision Shunt Regulators

AT431 Adjustable Precision Shunt Regulators FEATURES DESCRIPTION Programmable Output Voltage to 40V Voltage Reference Tolerance 1.0% for B Series and 0.5% for A Series Low Dynamic Output Impedance 0.22Ω Sink Current Capability of 0.1mA to 100mA

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 510-S/SP13 I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output VERSION 4.0 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany

More information

Model 3102D 0-2 kv H.V. Power Supply

Model 3102D 0-2 kv H.V. Power Supply Features Compact single width NIM package Regulated up to ±2000 V dc. 1 ma output Noise and ripple 3 mv peak to peak Overload and short circuit protected Overload, inhibit and polarity status indicators

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

8558A 8 1/2 Digit Multimeter

8558A 8 1/2 Digit Multimeter 8558A 8 1/2 Digit Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0) Order number 6ES7331-1KF02-0AB0 Properties 8 inputs in 8 channel groups Programmable resolution at each channel group (12 bits + sign) Programmable measurement type per channel group: Voltage Current Resistance

More information

TN-2 Interfacing with UltraVolt High Voltage Power Supplies Models A, AA, C, 10A-25A, 30A-40A, and F Series

TN-2 Interfacing with UltraVolt High Voltage Power Supplies Models A, AA, C, 10A-25A, 30A-40A, and F Series Introduction Interfacing with UltraVolt High Voltage Power Supplies Models A, AA, C, 10A-25A, 30A-40A, and F Series In this Technical Note, we provide tips for interfacing with the interconnection pins

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2018.12 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

IMP-2A ELECTRODE IMPEDANCE TESTER SINGLE CHANNEL

IMP-2A ELECTRODE IMPEDANCE TESTER SINGLE CHANNEL MicroProbes for Life Science IMP-2A ELECTRODE IMPEDANCE TESTER SINGLE CHANNEL User Instructions Version: October, 2015 18247-D Flower Hill Way Gaithersburg, MD 20879 Phone: +1 301 330-9788 Fax: +1 301

More information

Low Cost Three-Axis Fluxgate Sensor GFS-E. Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz

Low Cost Three-Axis Fluxgate Sensor GFS-E. Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz Handheld 3-Axis Gaussmeter Gaussmeter Fluxgate Low Cost Three-Axis Fluxgate GFS-E Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz Description: Low Cost Three-Axis

More information

2002 IS Catalog. Page

2002 IS Catalog. Page Page Introduction... 95 Current Repeaters/Drivers (Single-channel) KFD0-CS-Ex1.50P (Transmitter, positioner and indicator)... 96 KFD0-CS-Ex1.51P (Positioner and fire detector)... 97 KFD0-CS-Ex1.52 (Current

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V Thanks for buying our products,

More information

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab University of Jordan School of Engineering Electrical Engineering Department EE 204 Electrical Engineering Lab EXPERIMENT 1 MEASUREMENT DEVICES Prepared by: Prof. Mohammed Hawa EXPERIMENT 1 MEASUREMENT

More information

INSTRUCTION MANUAL Redox sensor M 1322 C

INSTRUCTION MANUAL Redox sensor M 1322 C INSTRUCTION MANUAL Redox sensor M 1322 C From version 2.01 2013 Controlmatik ABW d.o.o. 2 1. General... 7 1.1 Assembly... 8 1.2 Storage of Redox probes... 9 1.3 Connection to the electrical power supply...

More information

DOCUMENTATION. Its affordable price allows you to meet your budget target.

DOCUMENTATION. Its affordable price allows you to meet your budget target. DOCUMENTATION ULCOS is a real concentrate of technology, mixing performance and versatility. It is able to meet your high level expectation, for technical tender specifications. Its affordable price allows

More information

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in the mains lead are coloured In accordance with the following code: Green and Yellow:

More information

AI 043 S-DIAS Analog Input Module

AI 043 S-DIAS Analog Input Module AI 043 S-DIAS Analog Input Module Date of creation: 04.06.2014 Version date: 18.10.2017 Article number: 20-009-043-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18

More information

TARAline CS4. Data Sheet

TARAline CS4. Data Sheet TARAline CS4 indicator Application Chlorination agents Measuring system Electronic Information about the measuring range of sensors with 4-20 ma Accuracy after calibration at repeatability conditions (25

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

200GTL ALIGNMENT REVISION: 1.0 BURKE MODEL: 200GTL REVISION: 1.2 DATE: 02/14/06. Total Pages: 6 pages. Page:1 print date: 9/23/09

200GTL ALIGNMENT REVISION: 1.0 BURKE MODEL: 200GTL REVISION: 1.2 DATE: 02/14/06. Total Pages: 6 pages. Page:1 print date: 9/23/09 ALIGNMENT PROCEDURE MODEL: 200GTL REVISION: 1.2 DATE: 02/14/06 PREPARED BY: BURKE Total Pages: 6 pages Page:1 print date: 9/23/09 1 TEST CONDITION: 200GTL ALIGNMENT INSTRUCTION 1.0. TEST TEMPERTAURE: 77

More information

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-K-15195-01-02 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.10.2017 to 29.07.2019 Holder of certificate: Rohde

More information

Specifications. PCI Bus. Analog Input Input Characteristics

Specifications. PCI Bus. Analog Input Input Characteristics Specifications A This appendix lists the specifications of the NI 6034E/6035E/6036E. These specifications are typical at 25 C unless otherwise noted. The first section provides the specifications for the

More information

EC301 Potentiostat / Galvanostat

EC301 Potentiostat / Galvanostat User Manual EC301 Potentiostat / Galvanostat Stanford Research Systems Revision 1.2 (12/12/2017) Certification Stanford Research Systems certifies that this product met its published specifications at

More information

TL431 PROGRAMMABLE PRECISION REFERENCES FEATURES FUNCTION BLOCK DIAGRAM.

TL431 PROGRAMMABLE PRECISION REFERENCES FEATURES FUNCTION BLOCK DIAGRAM. PROGRAMMABLE PRECISION REFERENCES The TL43 is three-terminal adjustable shunt regulator with specified termal stability. The output voltage may be set to any value between V REF (Approx. 2.5V) and 36V

More information

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated

72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated P VA Digital panel meter with microprocess based technology digit PVE, PTE, PFE, PFL Galvanically insulated free scalable s/hysteresis Analogue galvanically insulated Min/max memy status //0 panelmeterx6analog_gb.doc

More information