96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply
|
|
- Annabella Singleton
- 5 years ago
- Views:
Transcription
1 m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status /0/04 panelmeter6x4_gb.doc page subject to alterations; errs including printer s errs 6x4
2 Digital panel meter Direct voltage Direct current Shunt Alternating voltage Alternating current Resistance Potentiometer PT00/PT000 Thermocouple m/s Direct voltage, direct current ORDER NUMBER (without option) 0 V 50 V V 600 V 0/40 ma 00 ma 0 V signal input (DC) 0 sens supply VDC 5 VAC 30 VAC Power supply 4 VDC Power supply 4 VDC (galv. insulated) DV C DV C DV C connections see page 6 Direct voltage (Shunt) 60 mv 50 mv mv V signal input (DC) 6 0 V VDC 5 VAC 30 VAC Power supply 4 VDC Power supply 4 VDC (galv. insulated) DV C DV C DV C Alternating voltage, alternating current V 0 V V 400 V A 5 A 0 V signal input (AC) VDC 5 VAC 30 VAC Standard DV C True effective value RMS DV C Power supply 4 VDC (galv. insulated) Standard DV C True effective value RMS DV C Resistance, potentiometer measurement bridge 0k Ohm bridge 00k Ohm bridge M Ohm Rx VDC 5 VAC 30 VAC Power supply 4 VDC Power supply 4 VDC (galv. insulated) DV C DV C DV C Thermocouple L, J K VDC Thermocouple 5 VAC 30 VAC Typ L (FeCuNi DIN) Typ J (FeCuNi americ.) Typ K (NiCrNi) 50 up to 500 C 50 up to 500 C 00 up to 00 C Power supply 4 VDC (galv. insulated) DT 3.40x.0C DT 3.40x.0C (fill in the desired type of thermocouple in the der number instead of x) status /0/04 panelmeter6x4_gb.doc page subject to alterations; errs including printer s errs DV3, DT3 6x4
3 PT00 ( wire) ORDER NUMBER OF TYPE (without options) PT00 (wire) VDC 5 VAC 30 VAC wire DT 3.0.0C (, C) wire DT C (600 C) 3 wire DT C (, C) 3 wire DT C (600 C) PT00 (3 wire) PT00 (wire) PT00 (3wire) VDC 5 VAC 30 VAC Power supply 4 VDC (galv. insulated) wire DT 3.0.0C (, C) wire DT C (600 C) 3 wire DT C (, C) 3 wire DT C (600 C) PT00 (4 wire) see panel meter with microprocess based technology PT000 ( wire) PT000 (wire) VDC 5 VAC 30 VAC Power supply 4 VDC (galv. insulated) Power supply 4 VDC (galv. insulated) wire DT C (, C) wire DT C (, C) wire DT C (600 C) wire DT C (600 C) OPTIONS DV Direct voltage DV Shunt DV Alternating voltage DV Resistance DT 3.40x... Thermocouple DT 3.x0.../3.x06... PT00/0 ( 3 wire) Additional price EUR LED green x x x x x x Protection IP54 at the front x x x x x x 6,5 Protection IP65 at the front (see following table) x x x x x x,0 Plug in terminal x x x x x,5 Sens supply 4 VDC/50 ma (supply voltage 30/5 VAC and 4 VDC) x 4,55 Sens supply 0 VDC/0 ma (supply voltage 30/5 VAC and 4 VDC) x 4,55 Sens supply 4 VDC/50 ma (supply voltage 4 VDC galv. insulated) x 35,0 Sens supply 0 VDC/0 ma (supply voltage 4 VDC galv. insulated) x 35,0 Sens supply 4 VDC/00 ma x 56,5 (supply voltage 30/5 VAC and 4 VDC galv. insulated) Sens supply 0 VDC/0 ma x 56,5 (supply voltage 30/5 VAC and 4 VDC galv. insulated) With supply voltage AC and DC (galvanically insulated) the sens supply is galv. insulated from the measuring input! Analog 00 VDC/ ma (supply voltage 30/5 VAC and 4 VDC) x x x x x x 3,0 Analog 00 ma/load 500 Ω (supply voltage 30/5 VAC and 4 VDC) x x x x x x 3,0 Analog 40 ma/load500 Ω (supply voltage 30/5 VAC and 4 VDC) x x x x x x 3,0 Analog 00 VDC/ ma (supply voltage 4 VDC galv. insulated) x x x x x x 6,35 Analog 00 ma/load500 Ω (supply voltage 4 VDC galv. insulated) x x x x x x 6,35 Analog 40 ma/load 500 Ω (supply voltage 4 VDC galv. insulated) x x x x x x 6,35 Analog with customer specified offset (S6) x x x x x x 0,5 Measuring input 0 ma (S0) x 5,35 Figures height 0 mm adjustment by potentiometer at the rear side (S33) x x x x x x 3,00 Dimension strips selectable x x x x x x Other power supplies on demand x x x x x x Setpoints See type PVE... status /0/04 panelmeter6x4_gb.doc page 3 subject to alterations; errs including printer s errs DT3 6x4
4 Settings ex wks with protective system IP65, adjustable on rear side Settings deviating from the standard settings must be indicated in the der description. As Standard desired Sign plus active inactive x x x x x Blanking no yes x x x x Indication time 0,5 sec. sec. x x x x Technical data DV Direct voltage DV Shunt DV Alternating volatge DV Resistance DT 3.40x... Thermocouple f all units of the DV3, DT3 series, if not indicated otherwise Dimension Housing B6 x H4 x T34 mm, including screw terminal (T=4 mm, including plug in terminal) Assembly cut out.0 0. x mm Fastening special quick plastic clamp proper to fix in wall thickness up to 50 mm Housing material PC/ABSblend, colour black, UL4V0 Protective system at the front IP40 connetion IP00 Weight approx kg Connection at the rear side via terminals up to.5 mm Input DV Direct voltage, Direct current Measuring range 00 V, 50 V, 00 V, 600 V, 0/40 ma, 000 ma all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (500 up to 500) Input resistance Ri with 0 V = ~55 kω 600 V = ~4. MΩ 50 V = ~0 kω 0 ma = ~00 Ω 00 V = ~. MΩ 00 ma = ~0 Ω DV Direct voltage (Shunt) Measuring range 060mV, 50mV, 300mV, V all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (00 up to 00) Input resistance Ri with 60mV = ~5kΩ 300mV = ~5kΩ 50mV = ~3kΩ V = ~30kΩ DV Alternating voltage, Alternating current Measuring range 0 V, 0 V, 00 V, 400 V, A, 5 A all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (00 up to 00) Input resistance Ri with V = ~0 kω 400 V = ~4 MΩ 0 V = ~00 kω A = ~6 mω 00 V = ~ MΩ 5 A = ~56 mω DV Resistance Measuring range 0 kω, 00 kω, MΩ all ranges selectable via connection terminal Offset adjustment suppted by offset potentiometer (00 up to 00) DT3.x0... PT00 Sens wire, 3wire Measuring range 50.0 up to. C Sens current approx. ma DT3.x06... PT00 Sens wire, 3wire Measuring range 00 up to 600 C Sens current approx. ma DT PT000 Sens wire Measuring range 50 up to, C Sens current approx. 0. ma DT PT000 Sens wire Measuring range 00 up to 600 C Sens current approx. 0. ma DT3.40x... Thermocouple L FeCuNi (DIN) 50 up to 500 C J FeCuNi (americ.) 50 up to 500 C K NiCrNi 00 up to 00 C Output DV Sens supply (galv. insulated f 30/5 VAC and 4 VDC/DC from the measuring input) 4 VDC/50 ma 0 VDC/0 ma (other sens supplies/perfmances on demand) F all versions Analog 00 VDC/ ma (0.% of measuring value, /0,05% of full scale) 00 ma, 40 ma load 500 Ω (0.% of measuring value, /0.05% of full scale) Offset Not changeable, offset cresponds to 0 digit, see options Final value Adjustable to 0 V 0 ma, within the indication range 350 to (The measuring inputs are not galv. insulated from the!) DT 3.x0.../3.x06... PT00/0 ( 3 wire) status /0/04 panelmeter6x4_gb.doc page 4 subject to alterations; errs including printer s errs 6x4
5 Technical data Output DT3.x0... Final value 00 C 0 V 0 ma adjustable f range from 35.0 C up to. C DT3.x06... Final value 600 C 0 V 0 ma adjustable f range from 00 C up to 600 C DT3.40x... Final value 500 C 0 V 0 ma adjustable f range from 00 C up to 500 C Final value 00 C 0 V 0 ma adjustable f range from 00 C up to 00 C Accuracy F all versions Measuring principle DualSlopeIntegration DV Temp. drift ~ 00 ppm/k DV ~ 50 ppm/k DV I ~ 00 ppm/k / U ~ 00 ppm/k DV ~ 00 ppm/k DT3.40x... ~ 00 ppm/k DT3.x0... ~ 00 ppm/k DT3.x06... ~ 00 ppm/k F all versions Measuring fault /0.% of measuring value, / digit DV3.0x4... Frequency range Nominal precision 40 Hz up to 000 Hz Measuring fault Voltage range: /0.5% of measuring value, /digit A range: /0.5% of measuring value, /digit 5 A range: /0.5% of measuring value, /digit Measuring principle (input) Via rectifier (effective value with sine wavefm only) DV3.x4... Frequency range Nominal precision 40 Hz up to 000 Hz Measuring fault Voltage range: /0.5% of measuring value, /digit, crestfact 3 A range: /0.5% of measuring value, /digit, crestfact 3 5 A range: /0.5% of measuring value, /digit, crestfact 3 Measuring principle (input) True effective value RMS Accuracy DT3.x0... Measuring fault max. /0,5 C, / digit DT3.x06... Measuring fault max. / C, / digit DT3.60x... Measuring fault R L 0 Ω = / K R L > 0 Ω 0 Ω = / K DT3.40x... Measuring fault type J, L max. 5 C Measuring fault type K Range from 00 C up to 50 C max. 5 C Range > 50 C up to 600 C max 5 C Range > 600 C up to 00 C max 5 C F all versions Resolution / digit DT3.x0... 0, C DT3.x06... C DT3.40x... C Power unit Supply voltage 30/5 VAC / 0% (5060 Hz), 4 VDC (30 V), 4 VDC (/0%) galv. insulated Consumption max. 5 VA Indication Display LED with segments, 4 mm high (optionally 0 mm), red 3½digit = indication Overflow by showing on the fourth digit DV DV DV Decimal point adjustable by bridging on front side Measuring time selectable 0.5 sec. Blanking blanking out of last digit (selectable by bridge on front side) Plus sign selectable by bridging on front side DV Decimal point adjustable by bridging on front side Measuring time selectable 0.5 sec. Blanking blanking out of last digit (selectable by bridge on front side) DT3.xx... DT3.xx6... Measuring time sec. Ambient Wking temperature 0 up to 60 C conditions Sting temperature 0 up to 0 C status /0/04 panelmeter6x4_gb.doc page 5 subject to alterations; errs including printer s errs 6x4
6 Housing: mm 6 mm mm Assembly cut out 0, mm,0 mm 0,0 mm 45,0 mm 0,6 mm 0,0 mm 4 mm 3 mm (with plug in terminal 4 mm) 6 mm Connection diagrams DV instruments without sens supply wire: 40 ma 3wire: 00 ma 3wire: 00 V / 05 V 40 ma 0 V / 6 V i.e. 4 VDC/DC i.e. 4 VDC/DC i.e.4 VDC/DC DV instruments with sens supply wire: 40 ma 3wire: 00 ma 3wire: 00 V / 05 V 40 ma 0 V / 6 V i.e. 4 VDC/DC i.e. 4 VDC/DC i.e. 4 VDC/DC wire: 40 ma 3wire: 00 ma 3wire: 00 V / 05 V 40 ma 0 V / 6 V i.e. 30 VAC i.e. 30 VAC i.e. 30 VAC status /0/04 panelmeter6x4_gb.doc page 6 subject to alterations; errs including printer s errs 6x4
96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply
m/s Digital panel meter 3½digit DV3, DT3 Without setpoints Analog Sens supply status 06/03/0 panelmeter_gb.doc page subject to alterations; errs including printer s errs Digital panel meter Direct voltage
More information48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output
kw Digital panel meter ½-digit DV, DT Without setpoints Analog status /0/04 - panelmeter_gb.doc page subject to alterations; errs including printer s errs Digital panel meter Direct voltage Direct current
More informationm/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication
P m/min Digital panel meter with 4½digit PV4, PT4, PF4, PW4 galvanically insulated free scalable setpoints/hysteresis optical setpoint indication analog galvanically insulated sens supply galvanically
More information72x36. Digital panel meter with microprocessor based technology 4-digit PVE4, PTE4, PFE4, PFL4. Galvanically insulated
P VA Digital panel meter with microprocess based technology digit PVE, PTE, PFE, PFL Galvanically insulated free scalable s/hysteresis Analogue galvanically insulated Min/max memy status //0 panelmeterx6analog_gb.doc
More informationDIGITAL PANEL INSTRUMENTS
DIGITAL PANEL STRUMENTS PVE, PTE, PFE, PFL Programmable Digital Panel Instrument x mm Programmable digital panel f moniting and control with different interfaces and inputs Direct voltage / current PT00/PT000
More informationminimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)
Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default
More informationminimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting
Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly
More informationminimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting
Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 25 mm without plug-in terminal adjustment via factory default or directly
More informationinstallation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)
Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal adjustment via factory default or directly
More informationinstallation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting
Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal min-/max-memory 30 additional adjustable
More informationminimal installation depth: 97 mm without plug-in terminal min-/max-value recording display flashing at threshold undercut/ exceedance
Digital panel meter 4-digit M1 red display with -1999 9999 digits (optional green, orange or blue displays) minimal installation depth: 97 mm without plug-in terminal adjustment via factory default or
More informationDIGITAL PANEL INSTRUMENTS
M2-1V.../ M2-1T... M2-1V.../ M2-1T... Case 96 x 48 mm Programmable Digital Panel 96 x 48 mm Red display of -1999 up to 99999 (optional green, orange, blue or tricolour display) Minimal installation depth:
More informationDigital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)
1 2 3 4 P Digital panelmeter with microprocessor based technology 5 digit PU5 Universal measuring input free configurable Measuring inputs: voltage, current, shunt, thermocouple, resistance, resistor thermocouple
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationEconomical Digital Indicators For Process and Electrical Measurement
Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.
More informationLight-strip indicator
/2 s /2 PROLUX 96 x 24 mm with 5 segments, /6 PROLUX 144 x 24 mm with 101 segments, /10 PROLUX 144 x 6 mm with 71 segments, Siemens MP 12 200 PROLUX 96 x 24 mm with 5 segments, Design The PROLUX light-strip
More informationSINEAX V 604s Programmable multifunctional transmitter
SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationDigital Indicator DS 96/48 PK
Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationDIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES
Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationUSB-2404-UI Specifications
Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise
More informationDRG-SC Series Signal Conditioners
DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable
More information20 General technical data XI/ON
20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationPROGRAMMABLE CONTROLLER
SERIES FP21 High Accuracy ±0.1% Programmable 9 Patterns and 9 Steps (81 Steps Max.) Auto-Tuning PID RA / DA Selectable User-Selectable Inputs (Thermocouple) User-Selectable Ranges Programmable Scaling
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationCTP16-Rotate. KMT - Kraus Messtechnik GmbH
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationDigital indicator for panel mounting With multi-function input Model DI25
Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation
More informationVersaPoint I/O Module
GFK-2012A March 2010 Module provides two-input channels for measuring signals from standard thermocouples. It supports thirteen different thermocouples types. In addition, it accepts linear voltage inputs
More informationBasic Series Square Panel Meters Features Benefits
Features Benefits Worldwide sales and service All panel meters can be supplied ex stock 1) Shunt resistors without protective cover (nominal current up to 1.5 ka) ASK 31.3 / ASK 412.4 current transformers
More informationDIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS
Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback
More informationTrip amplifier, 1 channel
Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5
More informationTransmitter / Signal Conditioning
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Transmitter / Signal Conditioning System Measuring input Direct connection
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationSEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER
RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION
More informationVersaPoint I/O Module
Module provides two-input channels for resistive temperature sensors. It supports platinum or nickel sensors according to the DIN standard and SAMA Directive. In addition, CU10, CU50, CU53, KTY81 and KTY84
More informationDIGITAL PANEL METER N24 AND N25 METER SERIES
DIGITAL PANEL METER N24 AND N25 METER SERIES USER S MANUAL Contents 1. APPLICATION...5 2. METER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1 Fixing Way...7 4.2 External Connection Diagrams...8
More informationDigital Indicator DS 96/24
Data Sheet 10/33-2.11-EN Digital Indicator DS 96/24 This indicator is suitable for measuring direct voltage or direct current. By using potentiometers, the digital display can be assigned to any input
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationJUMO di 32 / di 08. Brief description. Block structure
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 037 25 Fax: +49 (0) 661 60 036 81 EMail: mail@jumo.net Internet:
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationLOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION
EN K09LV LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION General Description The K09LV instrument is a three points galvanic insulator, with input on high sensitivity voltage, and active output.
More informationModule Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc
HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems
More informationDC1010/DC1020/DC1030/DC1040
05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and
More informationMeasurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Overview of ranges Selection guide Info & advice Economical range for industrial use μdigi1 - μdigi2 ranges Programmable range for universal
More informationAnalogue temperature controllers
Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications
More informationDEIF A/S. Insulation monitor. Type SIM-Q
Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on
More informationTransmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.
TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement
More informationVariTrans P V. Safe and Sound.
1000 V. Safe and Sound. VariTrans P 29000 Compact high-voltage isolation amplifiers with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection. Isolation Amplifiers
More informationDATA SHEET. Voltmeters and Ammeters,
DATA SHEET Voltmeters and Ammeters, Moving Coil (type ) Q48, Q72, Q96, Q144 90 or 240 pointer Accuracy class 1.5 Exchangeable scale (type x) Document no.: 4921210012S Application: Moving-coil instruments
More informationSefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website
Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal
More informationElectronic Thermostat TE-1 Version according to EN
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright
More informationEnglish. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM
English Operating manual Temperature measuring transducer MU125 Company / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents Page 1. Intended use (areas of application)...
More informationULTRASTAB IHF Precision Current Transducer
ULTRASTAB 867-200IHF Precision Current Transducer The Ultrastab 867-200IHF Current Transducer is a model in the Ultrastab Current Transducer program. It is the second generation of current transducers
More informationDIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges
ENERGY METERS 099 0 0 0 Overview of product range General overview Product selection guide by functions by applications Info & advice Keeping up with current changes µdigi and µdigi ranges x8 mm or 8x9
More informationDEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF
/ LF Insulation monitor Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range...kω or 1...MΩ Working frequency down
More informationIndicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN
Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm
More informationKS 40-1 burner Universal Burner Controller
Universal Burner Controller BluePort interface and BlueControl software aintenance anager and error list odulating, two or three stage regulation Automatic/manual and function key External setpoint and
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More information658 Current to Position Converters
658 Current to Position Converters Current to Position Converters for Solid State Switching Output Adjustable Zero, Span and Deadband Two Wire Input from Controller Operates with 90 to 1000 Ω Feedback
More informationN24, N25 DIGITAL PANEL METER
DIGITAL PANEL METER www.sifamtinsley.co.uk USER S MANUAL Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters DIGITAL PANEL METER Current Transformers
More informationONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:
X A L I S XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide display and signals transmission solutions. XALIS disign allows exceptional performances
More informationAnalog Modules AS-i IP20
(Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage
More informationFalcon F35 & F45 Digital Panel Meters
1/8 DIN Indicator 3-1/2 or 4-1/2 digit bright red LED display Front panel pops off for easy decimal point setting and display scaling Only 3.12 (79mm) required behind panel Optional excitation output NEMA
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationSHIMADEN PROGRAMMABLE CONTROLLER
SHIMADEN PROGRAMMABLE CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES FP21 High Accuracy ±0.1% Programmable 9 Patterns and 9 Steps (81 Steps Max.) Auto-Tuning PID RA / DA Selectable
More informationUltrasonic Sensor (HART)
Characteristics 500 - LEVEL - DISTANCE - MODULAR - ECONOMIC - Input: - Ranges - Output: - Voltage supply: - Accuracy: - Process connection: - Electrical connection: - Temperature range: - Limit value contacts:
More informationDigital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel
Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined
More informationDigital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40
Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable
More informationBASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter
Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationSEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications
Sefram SEFRAM Make sure to visit our Website http://wwwseframfr A new family of paperless recorders 6 to 72 channels, to cover all your applications 6 to 72 analogue channels Measurement boards : - 6 isolated
More informationVariTrans P D1 TRMS
Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True
More informationQ.raxx A slimline RS / EC
The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary
More informationSR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER
SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES SR25 MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER High Accuracy ±0.1% High Sampling Cycle 0.1 sec. Auto-Tuning
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationИ М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz
8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationTransducer for Measurement Bridges SCM90, SIGS15
Transducer for Measurement Bridges SCM90, SIGS15 General Description Transducer for measurement bridges for DINrails and for printed circuit boards. Programmable ranges and bridge supply, voltage or current
More informationULTRASTAB I U Precision
ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation
More informationR7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES
HONEYWELL MicroniK 1 R742B TEMPERATURE CONTROLLER GENERAL PRODUCT DATA The temperature controller R742B uses direct digital control technology to provide a more accurate and efficient operation of heating,
More information1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10
CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationMAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION
Data Sheet Load Monitoring Unit FEATURES For Use with Full-bridge Strain Gauge Transducers (Sensitivity 0.5 to 2 mv/v) Voltage Input for Different Charge Summation Summer with 4 Inputs Taring Facility
More information