DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges

Size: px
Start display at page:

Download "DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges"

Transcription

1 ENERGY METERS Overview of product range General overview Product selection guide by functions by applications Info & advice Keeping up with current changes µdigi and µdigi ranges x8 mm or 8x9 mm format - for industrial applications C.A 00, C.A 0 and C.A 00 ranges 8x9 mm format - for universal applications Synchronization instruments Synchro coupler 9 9

2 General overview Digital Panel Meters

3 Product selection guide 0? µdigi and µdigi ranges µdigi 0 µdigi 08 ENERGY METERS C.A 00, C.A 0 and C.A 00 ranges C.A 00 C.A 0 C.A 00 0 Synchronization instruments Synchro coupler SELECTION GUIDE INFO & ADVICE

4 Product selection guide Digital Panel Meters

5 SELECTING A PANEL METER ENERGY METERS µdigi µdigi ranges 08 0 C.A 00 C.A 0 C.A 00 ranges 0 µdigi µdigi CA 00 CA 0 CA 00 Format of front panel x 8 8 x 9 8 x 9 8 x 9 8 x 9 ADC resolution ± bits ± bits ± bits ± bits ± bits Number of digits displayed / / AC Ammeter µdigi E µdigi AAC C.A 00-E AC Voltmeter µdigi E µdigi VAC C.A 00-E Frequency meter µdigi F C.A 00-F C.A 00-D DC Ammeter µdigi E µdigi ADC C.A 00-E DC Voltmeter µdigi E µdigi VDC C.A 00-E Process signals µdigi P/LP µdigi PRC C.A 0-M C.A 00-P Measurement functions Thermocouple thermometer µdigi T µdigi TTC C.A 0-M C.A 00-T Pt 00 thermometer µdigi TPT C.A 0-M C.A 00-T Tachometer µdigi F µdigi TAC C.A 00-F C.A 00-D Counter C.A 00-I C.A 00-D Chronometer C.A 00-I C.A 00-D Load cell C.A 0-M C.A 00-C Potentiometer C.A 0-M C.A 00-P Special functions MIN/MAX µdigi ALP Analogue outputs Option Option Option RS output Option Option Option Outputs RS8 output µdigi ALP Option Option Option Threshold output(s) Option Option Option Option User-programmable Product advantages BCD output Economical programmable range for industrial use Programmable range for universal use Option GENERAL OVERVIEW INFO & ADVICE

6 Info & advice Digital Panel Meters KEEPING UP WITH CURR Digital panel meters are used to display an analogue value clearly and precisely. The digital processing allows these instruments to display different values, but also to connect them to external measurement or supervision systems. Several criteria influence the choice of a digital panel meter, the first of these being the scale or the measurement range, defined by the variation range of the signal to be measured. The resolution The number of display counts defines the resolution of the panel meter. The resolution is the necessary variation of the measurement signal required to vary the reading by one point. For a given rating, the greater the display capacity, the better the resolution. As an example, for an -bits (,000-counts) panel meter with a 0 V calibre, the resolution is 0 mv. However, for industrial applications, it is not always wise to choose a digital panel meter of too high resolution. The measurement signal may be subject to noise interference, resulting in the permanent instability of light weight display units. Accuracy Accuracy, which is not to be confused with resolution, defines the maximum variation between the instrument reading and the true value of the signal measured. It is expressed in the form: E = x % of the reading ± y counts. The first term is relative to the conversion method and the precision of the components, and the second to the different drift, dispersion, fluctuation and noise factors that can affect the instrument. The error is therefore constant over the entire measurement range. This is one of the main advantages of the digital panel meter over the galvanometer, where the most accurate readings are obtained at the end of the scale.

7 ENT CHANGES Format The format and the weight of the instrument must also be taken into consideration, affecting as they do the dimensioning of electrical cabinets. The format 8x9 (DIN standard 00) is the industrial standard. Alongside this, panel meters of reduced dimensions, such as the x, have proven especially useful for smaller-sized machines and embedded equipment. Display The visibility of panel meter display characters is directly linked to the light difference between the these and the screen background. LEDs, LCDs and backlit LCDs offer different levels of readability. LED technology, used on most of the ENERDIS range of digital panel meters, offers the best display contrast. A choice of red, green and amber colours also ensures they are easy to read. Display only or multifunction products? Panel meters are increasingly universal, and must be able to display both strong signals, such as the voltage of a network, and weak signals such as process signals. Instruments with multiple inputs, calibres and outputs are increasingly equipped with digital interfaces (RS, RS8) for remote communication, analogue outputs, and relay or alarm interfaces for connection to logic controllers. Number of digits and display points The display of a digital panel meter is characterized by the number of digits. We speak, for example, of / digit or / digit panel meters. A full digit has 0 possible states, in other words all values between 0 and 9. A / digit has a maximum value of and is capable of states: 0 and. A / digit can display a maximum value equal to and may comprise states: 0,,,. We can therefore expect a / digit panel meter to be capable of counting up to,000 (0 to,999), and a / digit panel meter to be capable of counting up to 0,000 (0 to,999). For this, the real display range of the apparatus must not be inferior. HOW TO GET THE BEST OUT OF YOUR PANEL METER Environment Digital panel meters, in general, are intended for interior use, their electronic circuit being sensitive to difficult climatic environments (in contrast to analogue panel meters, which are suitable for both interior and exterior use). They must also support emissions stimulated and emitted by the electrical equipment. Maintenance Unlike the analogue panel meter, the digital panel meter accepts low currents (maximum 00 V and A). It therefore requires only minimum precautions for the use of currents and voltages. QUIZ Test your knowledge: How many points can be displayed by a / digit panel meter? 0-,000 counts 0-,999 counts 0-9,999 counts What character colour gives the greatest readability? White Blue Red What is the format most widely used? x8 mm 8x9 mm x9 mm GENERAL OVERVIEW SELECTION GUIDE 99 0 ENERGY METERS Consult the answers on: 0 0

8 µdigi range Digital Panel Meters µdigi-lp -0 ma process signal µdigi-p U/I process signal µdigi-e AC/DC voltage/current µdigi RANGE x 8 mm programmable panel meters for industrial use Plug-in connectors for quick and easy connection Display with levels of brightness Remote configuration of the µdigi-alp via the RS8 serial link µdigi-t Temperature (Pt00, thermocouple) µdigi-f Frequency, rpm, pulse µdigi-alp Process signals with alarms PRODUCT ADVANTAGES Display with LEVELS OF BRIGHTNESS Instant MOUNTING WITHOUT TOOLS SIMPLE PROGRAMMING using keys COMPACT DIMENSIONS -POINT LINEARIZATION of the input signals on the µdigi-alp Programming Quick and easy: - Local programming using the keys of the keyboard. Only the instructions required for the application are shown. No mistakes are possible. Access to programming can be protected on all the instruments. - Remote programming with the µdigi-prg software available free on the site for the µdigi-alp with RS8 option.

9 µdigi-lp -0 ma process signal µdigi-p U/I process signal µdigi-e U/I voltage and current Input: -0 ma Display range: -, ,999 Input: Vdc Vdc Vdc ( MΩ) Vdc (00 MΩ) madc (. Ω) Display range: -, ,999 T O O R D E R Input: 00 Vac 00 Vac Vdc Vdc ( MΩ) Aac Aac Adc - + Adc ( mω) Display range: -,999 9,999 (dc) 0 9,999 (ac) ENERGY METERS Power supply Self-powered (active loop) P µdigi-t Temperature (Pt00 and thermocouple) Power supply 8 - Vac & Vdc P Vac & Vdc P0 0 0 µdigi-f Frequency, rpm, pulse Power supply 8 - Vac & Vdc P Vac & Vdc P0 0 0 µdigi-alp Process signal with alarms Pt00 : C C -8 +, F C J : C -8 +, F K : -0 +,0 C -8 +,8 F T : C -8 + F Display range: -,999 9,999 Frequency meter: 0.0 Hz... khz (voltage 0 to 00 Vac) Tachometer: Magnetic Vin > 0 mv rms (0 Hz) Vin > 00 mv rms ( Hz) NAMUR Rc =. kω ; Ion < ma ; Ioff > ma NPN/PNP Rc =.9 kω (NPN) ;. kω (PNP) 0 <. V / >. V Encoder/TTL/V 0 <. V / >. V SWITCH Vc = V (internal) Rc =.9 kω (internal) Fc = 0 Hz Display range: 0 9,999 Entrée : Vdc Vdc ( MΩ) mvdc (00 MΩ) madc (. mω) Display range: -,999 9,999 -segment signal linearization T O O R D E R Power supply 8 - Vac & Vdc P Vac & Vdc P0 0 0 Associated products Voltmeter / ammeter switches 9 Current transformers & shunts Power supply 8 - Vac & Vdc P Vac & Vdc P0 0 0 Thermocouple / probe Catalogue Power supply Option 8 - Vac & Vdc - P Vac & Vdc - P Vac & Vdc RS8 P Vac & Vdc RS8 P0 0 0 SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD

10 µdigi range Digital Panel Meters µdigi RANGE x 8 mm programmable panel meters for industrial use Display µdigi-lp µdigi-p µdigi-e µdigi-t µdigi-f µdigi-alp ADC Resolution bits ± bits Measurement rate /s /s Display range -,999 9,999 -,999 9,999 -,999 9,999 (dc) 0 9,999 (ac) -,999 9, ,999 -,999 9,999 -segment red LED display Height 0mm Height 8mm Reading digits Polarity automatic Overrun OVE display Decimal position Programmable using software Accuracy µdigi-lp µdigi-p µdigi-e µdigi-t µdigi-f µdigi-alp ±0. % + counts ± 0.% + counts - ± 0.% + counts for 00 V/Aac inputs Pt00 C : ±0. % + count (Res ) - ±0. % + counts (Res 0. ) F : ±0. % + counts (Res ) - ±0. % + counts (Res 0. ) "J, K and T" thermocouples C : ±0. % + counts (Res ) F : ±0. % + counts (Res ) ±0.0 % + count ±0. % + count Mechanical specifications Material polycarbonate as per UL9 V-O Weight 0 g 0 g (µdigi-lp) 0 g (µdigi-alp) Protection rating front panel IP Mounting on panel with self-locking strap Environment Operating temperature -0 C to +0 C Storage temperature - C to + 8 C Relative humidity < 9% at +0 C Max. altitude,000 m Power supply High level Low level Consumption 8/ Vac 0/0 Hz 00/00 Vdc / Vac 0/0 Hz 0./0 Vdc. W (< W for µdigi-alp)

11 Standards Insulation dielectric strength: EN 00- (category II installation) EMC immunity/emission: EN 000--, EN 000--, EN / EN 0 (EN for µdigi-lp and µdigi-alp EN and EN for µdigi-alp) Dimensions (in mm) ENERGY METERS µdigi-lp µdigi-p µdigi-e µdigi-t µdigi-f µdigi-alp (a) 0 mm 0 mm 00 mm Panel drilling specifications (in mm) SELECTION GUIDE INFO & ADVICE RANGE INFO

12 µdigi range Digital Panel Meters µdigi VAC AC VOLTAGE µdigi VDC DC VOLTAGE µdigi TPT TEMPERATURE Pt 00 µdigi PRC PROCESS SIGNAL U/I µdigi RANGE Programmable panel meters in 8 x 9 mm format for industrial applications Easy programming using three front panel keys Accessories for surface and DIN rail mounting Quick connection using plug-in connectors Easy installation of card options µdigi AAC AC CURRENT PRODUCT ADVANTAGES µdigi ADC DC CURRENT ECONOMICAL single-function range INSTANT FITTING without tools µdigi TTC Thermocouple Temperature Mounting accessories Multi-position fitting with DIN rail adapter Back fitting with DIN rail adapters P0 9 0 P0 9 0 Optional card -relays alarm card P0 9 0 µdigi TAC TACHOMETER

13 µdigi VAC AC Voltage µdigi VDC DC Voltage µdigi TPT Temperature Pt 00 µdigi PRC Process Signal U/I ENERGY METERS Direct (0 Hz to khz) : 0 V (90 kω) 00 V ( MΩ) 00 V ( MΩ) Direct : 0 V (90 kω) 00 V ( MΩ) 00 V ( MΩ) C (0 Ω/wires) C (0 Ω/wires) 0 ±0 V ( MΩ) 0 ±0 ma (. Ω) Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F T O O R D E R Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F µdigi AAC AC Current µdigi ADC DC Current µdigi TTC Temperature Thermocouple µdigi TAC Tachometer Direct or on CT (0 Hz to khz) : A (0.0 Ω) A (0.0 Ω) On shunt (0 Hz to khz) : 00 mv ( kω) 0 mv (00 mω) Direct : A (0.0 Ω) A (0.0 Ω) On shunt : 00 mv ( kω) 0 mv (00 mω) J : C C K : C -0 +,0 C T : C Frequency: 0 to 999,9 Hz Speed: 0 to 9,999 counts Magnetic sensor: Vin > 0 mvrms NAMUR sensor Encoder TTL/ V or NPN/PNP Dry contact Voltage: 0 to 0 Vac T O O R D E R Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F Supply /0 Vac 0 0F /8 Vac 0 0F Vdc 0 0F Vdc 0 0F 8 Vdc 0 0F Supply /0 Vac 0 08F /8 Vac 0 08F Vdc 0 08F Vdc 0 08F 8 Vdc 0 08F Associated products Voltmeter and ammeter switches 9 Accessories and option cards 08 CT Current transformers and shunts Thermocouple / probe Catalogue SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD

14 µdigi range Digital Panel Meters µdigi RANGE Programmable panel meters in 8 x 9 format for industrial applications Display ADC resolution ± bits AAC, VAC, ADC, VDC, PRC -,999 9,999 Display range TPT, TTC -,999,999 TAC frequency TAC speed 0 9,999 Display indicators Red LED segments Height. mm Reading digits Polarity Automatic Overrun OVE displayed Decimal position Programmable by software AAC, VAC, ADC, VDC, PRC measurements / second Measurement rate TPT, TTC measurements / second TAC 0. Hz to to khz Accuracy AAC, VAC, ADC, VDC, PRC ±0. % ± counts TPT network 0. C ±0. % +0. C TPT network C ±0. % + C TTC tc J, K, T : 0. C ±0. % +0. C TTC tc J, K, T : C ±0. % + C TAC 0. % ± pts Mechanical specifications Material Weight Protection rating Fitting polycarbonate V0 as per UL9 0 g IP on front panel On panel using self-locking Environment Operating temperature - 0 to + 0 C Storage temperature - to + 8 C Relative humidity < 9 % at + 0 C Maximum altitude,000 m Power supply AC voltage Consumption DC voltage Consumption / 0 Vac ± % 0 / 0 Hz / 8 Vac ± % 0 / 0 Hz VA Vdc (0- Vdc) Vdc (- Vdc) 8 Vdc (- Vdc) W

15 Standard Low voltage directive //CEE Insulation - dielectric strength IEC 00- Dimensions (in mm) ENERGY METERS Panel drilling specifications (in mm) (drilling) (drilling) SELECTION GUIDE INFO & ADVICE RANGE INFO

16 The C.A 00 range Digital Panel Meters C.A 00-E C.A 00-F C.A 00 RANGE Programmable digital panel meters in 8 x 9 format for universal use Easy programming using three front panel keys Accessories for surface and DIN rail mounting Quick connection using plug-in connectors Easy installation of card options C.A 00-I PRODUCT ADVANTAGES REDUCED DEPTH for easy installation in cabinets and on equipment RECORDING of maximum and minimum values of input variable SERIAL LINK for remote processing of measurement data Description With its communication option, the C.A 00 is suitable for supervision via a PC, logic controller or any other "master" system: the measurement readings may be obtained on PC via a serial link. Optional cards* Card C.A XXX AL Relays P0 9 0 Card C.A 00 RS/RS8 communication P0 9 0 *Additional cards (complement or replacement) Mounting accessories Multi-position fitting with DIN rail adapters P0 9 0 Rear fitting with DIN rail adapters P0 9 0 Connector + m RS cable P0 9 0 Connector + m RS8 cable P0 9 0 Kit of x C.A 00 screw connectors P0 9 0 Converter RS F/RS8 - screw P0 9 0

17 C.A 00-E Electrical quantities AC/DC C.A 00-F Frequency meter / Tachometer C.A 00-I Counter / Chronometer ENERGY METERS Voltage ( ratings) : 00 Vac/dc max - 80 Hz max Current ( ratings) : Aac/dc max Shunt ( ratings) : 00 mv max Magnetic sensor: Vin > 0 mveff NAMUR sensor: Ion < madc / Ioff > madc Rc = kω TTL/V encoder or NPN/PNP sensor: "" >. Vdc / "0" <. Vdc Dry contact: Vc = V / Rc =.9 kω Fc = 00 Hz Voltage: 0 to 0 Vac (Fmin 0. Hz / Fmax khz) Magnetic sensor: Vin > 0 mveff NAMUR sensor: Ion < madc / Ioff > madc Rc = kω TTL/V encoder or NPN/PNP sensor: "" >. Vdc / "0" <. Vdc Dry contact: Vc = V / Rc =.9 kω Fc = 00 Hz (Fmin 0. Hz / Fmax khz) T O O R D E R Customized products E.g. Model Auxiliary power supply Alarm Analogue output Digital communication C.A 00-E X X /0 Vac: Vdc: /8 Vac: Vdc: without: X relays: without: X -0 ma: options maximum without: X RS/RS8: Associated products Voltmeter and ammeter switches Accessories and option cards CT Current transformers and Shunts Thermocouple / probe SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD Catalogue

18 C.A 00 range Digital Panel Meters C.A 00 RANGE Programmable digital panel meters format 8 x 9 mm Displays C.A 00-E C.A 00-F C.A 00-I Measurement points ± bits Frequency meter : Counter : Etendue d'affichage DC : 0 9, ±9,999 AC : ,999 Tachometer : Chronometer : 0 9, s 9,999 h Display indicators Red LED segments, Height, mm Reading digits Polarity automatic Overrun OVE displayed Decimal position Programmable by software Display blocking Function MIN / MAX Display rate measurements/second < measurement/second < measurement/second Response time 00 ms 0. to 9.9 s - OFFSET function OFFSET C.A 00-E C.A 00-F C.A 00-I pushbutton memorization Sensor excitation C.A 00-E C.A 00-F C.A 00-I Sensor excitation 8 V or Vdc/0 ma 8 V or Vdc/0 ma Accuracy C.A 00-E C.A 00-F C.A 00-I dc : 0. % Measurements ± counts ±0. % ±0.0 % ac : 0. % ± counts ± count ± counts Temperature coefficient 00 ppm/ C 0 ppm/ C 0 ppm/ C Mechanical specifications Material Polycarbonate VO as per UL Weight 0 g (without option) 0 g (without option) Protection rating IP on front panel Fitting On panel using self-locking strap

19 Environment Operating temperature 0 to +0 C Storage temperature - to +8 C Relative humidity < 9 % at +0 C ENERGY METERS Supply AC voltage Consumption DC voltage Consumption bivoltage /0 Vac ± % 0/0 Hz bivoltage /8 Vac ± % 0/0 Hz VA 0. Vdc or Vdc W Standards Low voltage directive //EEC Isolation - dielectric strength IEC 0- Dimensions (in mm) Panel drilling specifications (in mm) (drilling) (drilling) SELECTION GUIDE INFO & ADVICE RANGE INFO 0 0

20 C.A 0 range Digital Panel Meters C.A 0-M C.A 0 RANGE 8 x 9 mm programmable digital panel meter. Process, temperature and load cell in the same product. display colours Quick connection using plug-in connectors (spring-cage type) Remote configuration via the RS or RS8 serial link PRODUCT ADVANTAGES PRODUCT, FUNCTIONALITIES DISPLAY COLOURS INSTANT MOUNTING WITHOUT TOOLS INPUT SIGNAL LINEARIZATION OVER 0 SEGMENTS SERIAL LINK for remote processing of measurement data PREPROGRAMMED COMMAND FUNCTIONS available on isolated inputs Description The C.A 0-M is a -in- programmable panel meter which can be configured for process, temperature or load-cell signals. The serial link allows remote processing of the measurements on a PC. The CA0-PRG software, available free of charge from the site allows direct reading of the measurements, as well as remote configuration and programming of one or more connected panel meters. It can also be used to save and retrieve the configuration of an existing panel meter. Optional cards* Model Card C.A XXX AL relays P0 9 0 Card C.A XXX AL relays P0 9 0 Card C.A XXX AL NPN P0 9 0 Card C.A XXX COM RS P0 9 0 Card C.A XXX COM RS8 P0 9 0 Card C.A 0 Output 0-0 V P0 9 0 Card C.A 0 Output - 0 ma P0 9 Accessories Model Multiple mounting with DIN-rail adapters P0 9 0 Connector + m cable RS P0 9 0 Connector + m cable RS8 P0 9 0 * Extra cards (addition or replacement)

21 Process input Measurement of process signals from the most widely-used low-level sensors, in the ±0 V or ±0 ma range. The panel meter can also be connected to a potentiometric converter to measure displacement, length, etc. Temperature input Temperature measurement using thermocouple probes (J, K and T) and Pt00 probes.the measurements can be displayed in C or F, with a resolution of one degree or one tenth of a degree. Load cell input Measurement of loads (masses, forces, torques, pressures, etc.) using low-level sensors such as strain gauge bridges. Options available Card with alarms on relays Outputs Max. voltage Max. current x RT relays 0 Vac or Vdc 8 A at 0 Vac or 8 A at Vdc Card with alarms on relays Outputs Max. voltage Max. current x T relays 0 Vac or 0 Vdc 00 ma at 0 Vac or A at 0 Vdc ENERGY METERS Card with alarms on NPN transistor Outputs Max. voltage Max. current Communication card NPN optocouplers 0 Vdc 0 ma at 0 Vac Analogue output card Output signal V... 0 ma Accuracy 0.% ± digit Temp. coeff. 0. mv per K 0. ma per K Max. load > 00 Ω < 800 Ω Type of link RSC RS8 Protocol ISO, C.A protocol or ModBus/RTU Speed,00,,00,,800, 9,00 or 9,00 bauds RJ- with Output connector RJ9- double adapter (input and output) T O O R D E R Customized product Model Auxiliary power supply Alarm Analogue output Digital communication E.g. C.A 0-M X 8- Vac & Vdc : - Vac & 0.-0 Vdc : None : X relays : relays : transistors : None : X -0 ma : 0-0 V : None : X RS : RS8 : Associated products Voltmeter and ammeter switches 9 Current transformers and shunts Thermocouple / probe Catalogue SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD

22 C.A 0 range Digital Panel Meters C.A 0 RANGE 8 x 9 mm programmable digital panel meters Display C.A 0-M ADC resolution ± bits Measurement rate Load cell process 0 / second Pt00 / second CT 0 / second Display range - 9,999 to +9,999 Display units -segment programmable colour LED (red, green, amber), height mm Reading digits Polarity automatic Overrun -ouer Decimal position by programming Sensor excitation C.A 0-M Process V (0 ma) - 0 V / V (0 ma) Load cell 0 V (0 ma) - V (0 ma) Potentiometer 0 V (0 ma) Pt00 < ma dc Mechanical specifications C.A 0-M Material polycarbonate as per UL 9 V-0 Weight 0 g Protection rating IP on front panel Mounting On panel using self-locking strap Environment C.A 0-M Operating temperature -0 C to +0 C Storage temperature - C to +80 C Relative humidity < 9% at 0 C Maximum altitude,000 m Power supply High level Low level Consumption C.A 0-M 8/ Vac 0/0 Hz - 00/00 Vdc / Vac 0/0 Hz - 0./0 Vdc W without option, 8 W max. Special functions Reset to factory configuration Change of display colour Total or partial locking of programming by code Display with brightness levels Accuracy C.A 0-M Temperature coefficient 00 ppm/ C Warm-up time 0 minutes Measurements Process Voltage: mv Current: µa Load cell µv Potentiometer 0.00 % of the display Temperature 0. / (selectable)

23 Standards Insulation dielectric strength: EN 00- (Category II installation) EMC Immunity: EN 000--, EN 000--, EN 000--, EN 000--, EN 000--, EN EMC Emission: EN 0 ENERGY METERS Dimensions (in mm) Panel drilling specifications (in mm) (drilling) (drilling) SELECTION GUIDE INFO & ADVICE RANGE INFO

24 C.A 00 range Digital Panel Meters C.A 00-P C.A 00-C C.A 00-T C.A 00 RANGE Programmable panel meters in 8 x 9 mm format for universal use Easy programming using five front panel keys Accessories for surface and DIN rail mounting Quick connection using plug-in connectors Easy installation of card options C.A 00-D PRODUCT ADVANTAGES RECORDING of maximum and minimum values of input variable SERIAL LINK for remote processing of measurements LINEARISATION of input signal over segments Description On the instruments, two digital filters can be activated to stabilise the display of measurements depending on the processing conditions. The measurement display can be disabled remotely by closing a contact.the display and reset of MAX and MIN values can also be activated remotely. On the C.A 00-P and C.A 00-C, activation and cancellation of the OFFSET function can also be controlled remotely.the OFFSET command functions may be modified by the user, with functions in all being pre-programmed on the instruments. On the C.A 00-P and C.A 00-C models, the display can also be set to flashing mode to indicate an alarm threshold overrun. Option cards* Model Card C.A XXX AL relay P0 9 0 Card C.A XXX AL relay P0 9 0 Card C.A XXX AL NPN P0 9 0 Card C.A 00 analogue output P0 9 0 Card C.A 00 BCD output P Card C.A XXX RS Communication P0 9 0 Card C.A XXX RS8 Communication P0 9 0 Accessories Model Multi-position fitting with DIN rail adapters P0 9 0 Rear fitting with DIN rail adapters P0 9 0 Connector + m RS cable P0 9 0 Connector + m RS8 cable P0 9 0 Kit of x C.A 00 screw connectors P0 9 0 Converter RS F/RS8 - screw P0 9 0 * Additional cards (complement or replacement)

25 C.A 00-P Process signal U/I DC C.A 00-C Load cell ENERGY METERS Voltage : 0 to ±0 V on MΩ Current : 0 to ±0 ma on Ω Potentiometer : MΩ 0 to ± mvdc on 00 MΩ 0 to ±0 mvdc on 00 MΩ 0 to ±0 mvdc on 00 MΩ 0 to ±00 mvdc on 00 MΩ C.A 00-T Temperature C.A 00-D Frequency meter / Tachometer Counter / Chronometer tc J : -0 to +80 C / -8 to +, F tc K : -0 to +,00 C / -8 to +,9 F tc T : -00 to +00 C / -8 to + F tc R : 0 to,00 C / - to +,09 F tc S : 0 to,00 C / - to +,09 F tc E : -0 to +,000 C / -8 to +,89 F Pt 00 : -00 to +800 C / -8 to +, F Magnetic sensor:vin > 0 mvrms NAMUR sensor: Ion < madc / Ioff > madc / Rc = kω TTL/V encoder or NPN/PNP sensor: "" >. Vdc / "0" <. Vdc Dry contact: Vc = V / Rc =.9 kω / Fc = 00 Hz Voltage : 0 to 0 Vac (Fmin 0. Hz / Fmax khz) T O O R D E R Customized products E.g. Model Auxiliary power supply Alarm Analogue output Digital communication C.A 00-P X X /0 Vac : /8 Vac : 0/0 Vdc : without : X relays : relays : transistors : without : X 0-0 V / -0 ma : without: X RS : RS8 : BDC : * * Choice of the BCD output cancels the alarm and analogue outputs Associated products Voltmeter and ammeter switches Accessories and option cards CT Current transformers and Shunts Thermocouple / probe SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD Catalogue 0

26 C.A 00 range Digital Panel Meters C.A 00 RANGE Programmable digital panel meters in 8 x 9 format for universal use Display C.A 00-P C.A 00-C C.A 00-T C.A 00-D ADC resolution ± bits ± bits ± bits - Counter: ±,000 Tachometer: 0 99,999 Display range ±,000 ±,000 ±,000 Chronometer: 0.00 s to 9,999.9 h Frequency meter: 0 to,000 Display indicators Red LED segments, Height. mm Reading digits Polarity automatic Overrun OVE displayed Decimal position Programmable by software Display blocking MAX/MIN function Measurement rate measurements / second Response time ms (0,, or ms depending on filter programmed) Function C.A 00-P C.A 00-C C.A 00-T C.A 00-D OFFSET function on keyboard on keyboard by programming on keyboard Display blocking: Remote control ( logical inputs) pre-programmed functions 8 pre-programmed MIN/MAX/RESET functions and clear MIN/MAX/RESET display Sensor excitation Sensor excitation C.A 00-P C.A 00-C C.A 00-T C.A 00-D 0 ma at or 0 V or 0 ma at V 0 ma at or 0 V - 8 V or Vdc / 0 ma Accuracy C.A 00-P C.A 00-C C.A 00-T C.A 00-D Measurements 0. µa or 0. µa 0.0 % R ± counts 0. C or C 0.0 % R ± count Temperature coefficient 0 ppm/ C 00 ppm/ C 00 ppm/ C 0 ppm/ C Mechanical specifications Material Weight Protection rating Fitting Polycarbonate VO as per UL g (without option) 80 g (with options) IP on front panel On panel using self-locking strap

27 Environment Operating temperature 0 to +0 C Storage temperature - to +8 C Relative humidity < 9 % at +0 C ENERGY METERS Power supply AC voltage Consumption DC voltage Consumption bivoltage /0 Vac ± % 0/0 Hz bivoltage /8 Vac ± % 0/0 Hz VA without option, 0 VA max 0 to 0 Vdc W without option, 0 W max Standards Low voltage directive //EEC Insulation - dielectric strength IEC 0- Dimensions (in mm) Panel drilling specifications (in mm) (drilling) (drilling) SELECTION GUIDE INFO & ADVICE RANGE INFO 0 0 0

28 Synchro coupler range Digital Panel Meters Synchro coupler PID Synchro coupler SYNCHRO COUPLER RANGE LED display of measurements: phase, frequency and voltage Displays deviations between setpoint and measurement values User-programmable on front face PRODUCT ADVANTAGES INTEGRATED IN 9 x 9 FORMAT: Adjustments carried out in seconds (PID model) synchronization command adjustment command synchronization command modes Description The SYNCHRO COUPLER is an automatic synchronization instrument for generator sets. It includes: - a control relay for assisted manual coupling or automatic coupling with time delay control - two control relays (fast/slow) for speed adjustment - an external control loop for opening the coupling relay - four front panel keys for programming, display and messages (password option included)

29 SYNCHRO COUPLER PID SYNCHRO COUPLER ENERGY METERS Display: phase angle variations by 0 LEDs disposed in a circle voltages, frequencies, variations (in %) on digits frequency variations ±, status of coupler relay, conditions obtained in phase, frequency and voltage Display: as for synchro coupler PID adjustment method (Proportional Integral Derivative) for synchronization that is faster and more accurate than with conventional synchronous couplers Proportional: proportional correction of measurement errors Integral: guarantees reduction of adjustment error to 0 Derivative: brings greater stability to the system, enabling you to anticipate the inertia of generator sets (e.g. hydroelectric) T O O R D E R Power Supply 0 VAC LS9N X 0 VAC LS9N X 00 VAC LS9N X Power Supply 0 VAC LS9N X 0 VAC LS9N X 00 VAC LS9N X SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD. 0 0

30 Synchro coupler range Digital Panel Meters SYNCHRO COUPLER RANGE Synchronization instruments for LV networks Electrical specifications Voltage inputs Nominal voltage 80 Vac Range 0 to 00 V Frequency 80 Hz Consumption < 00 µa Relay outputs Sealed inverter deviation 8 A - 0 Vac / A - 0 Vdc Multimeter measurements (accuracy) Phase angle deviation ± 0. Frequency ± 0.0 Hz Voltage (RMS) Class ± digits Auxiliary supply AC voltage - 0 % / + % Frequency...0 Hz Consumption 0 VA Environment Operating temperature -0 C to + C Storage temperature -0 C to +0 C Relative humidity < 90 % at 0 C Protection rating Pollution level Mechanical specifications Casing materials Casing and flange Front panel Protection rating Weight Connection Fitting Self-extinguishing black ABS Light grey polycarbonate IP front panel (IP optional) 0g Holder for. mm wire Mounting on 8 mm front panel

31 Mechanical specifications standards Safety IEC 00- Dimensions DIN 00 EMC EN - ANSI function Nos. and 90 Resistance to shock IEC Resistance to vibrations IEC Environment IEC 008- ENERGY METERS Electrical specifications Dimensions and drilling specifications (mm) Speed control SYNCHRO 9.0 Vg0 Vg F.G0 F.G V% F.% Enb V F Fitting flange Control loop Auxiliary supply G0 Generator G Panel cut-out SELECTION GUIDE INFO & ADVICE RANGE INFO 0 0

Measurement and Instrumentation

Measurement and Instrumentation POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Overview of ranges Selection guide Info & advice Economical range for industrial use μdigi1 - μdigi2 ranges Programmable range for universal

More information

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40 Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of

More information

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven) Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

Multifunctional counter tico 772/773/774

Multifunctional counter tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

DIGITAL PANEL INSTRUMENTS

DIGITAL PANEL INSTRUMENTS M2-1V.../ M2-1T... M2-1V.../ M2-1T... Case 96 x 48 mm Programmable Digital Panel 96 x 48 mm Red display of -1999 up to 99999 (optional green, orange, blue or tricolour display) Minimal installation depth:

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined

More information

ONE CALIBRATOR ONLY MAIN FEATURES:

ONE CALIBRATOR ONLY MAIN FEATURES: ONE CALIBRATOR ONLY The MEMOCAL 2000 is a lightweight versatile, portable, hand-held calibrator developed to solve two different and coexisting customer needs: field calibration (maintenance) and laboratory

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

MEMOCAL 2000/2000S. Hand-held calibrator

MEMOCAL 2000/2000S. Hand-held calibrator MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Analog Digital Multimeter with Insulation Resistance Measurement

Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,

More information

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

Device manual Multifunction display and evaluation system FX 360. Mode/Enter Device manual Multifunction display and evaluation system FX 360 7390275 / 08 07 / 2009 Mode/Enter Set Safety instructions This manual is part of the unit. It contains texts and diagrams for the correct

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01% Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,

More information

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13. LDI 35 OPERATING INSTRUCTIONS General features 2 Technical features 3 Installation 10 Preliminary operations 12 Front panel description 13 Operating mode 15 Important: We suggest you keep the original

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

Position Indicator with/without Limit Values

Position Indicator with/without Limit Values .1 Position Indicator with/without Limit Values Large, 6-digit, 14 mm high LED display Prescaler 2 variable limit values Eeasy direct selection by 2 function keys Rrelay output with two change-over contacts

More information

GAMMA 10 DIGITAL MULTIMETER

GAMMA 10 DIGITAL MULTIMETER Gamma 10 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

S T T U S I N S T R U M E N T S

S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DIN rail mounting temperature controller with current transformer input deltadue series D1 line BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

GAMMA 12 DIGITAL MULTIMETER

GAMMA 12 DIGITAL MULTIMETER Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

em4 local - Robust Specific characteristics Part number

em4 local - Robust Specific characteristics Part number em4 em4 local em4 local Very compact and easy to program nanoplc Save time in designing your application using the most intuitive graphical function block language of the market Measure accurately your

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN Each click of a dial opens a doorway to precision. Precision DC Calibrator Bulletin -01EN Yokogawa is a leader in providing high precision measurement equipment electric voltage/current, electric resistance,

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet 5492B T The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service repair, and manufacturing. The instrument enhances

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Energy Management Energy meters Type EM2-DIN

Energy Management Energy meters Type EM2-DIN Energy Management Energy meters Type 6-dgt µp-based indicator Manual scrolling of partial and total energies: kwh, kvarh. TRMS measurement of distorted waves (voltage/current) All configuration functions

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver with Wireless Data Transmission Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured

More information

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Multifunction Intelligent 4-wire Isolated Signal Conditioner Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

Indicators and configurable displays

Indicators and configurable displays Contents Overview.2 Process value displays with LED display.4 Process value displays with LCD display.20 1460730000 2014/2015.1 Overview In industrial and process automation, displays provide a visual

More information

TxBlock-USB Transmitter

TxBlock-USB Transmitter Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

CALYS 75. Field documenting multifunction calibrator

CALYS 75. Field documenting multifunction calibrator Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.

More information

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

M.3. Electrical measurement and control. Electrical energy meters for partial consumption M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction

More information

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol

More information

Measurement and control. Digital instruments and measuring transducers

Measurement and control. Digital instruments and measuring transducers Measurement and control Digital instruments and measuring transducers M.2 - Digital instruments and measuring transducers Introduction...M2-3 Product selection table...m2-5 DC Series Digital indicator

More information

Flexible Counter Series in DIN size 24 x 48 mm

Flexible Counter Series in DIN size 24 x 48 mm Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information