Modicon Momentum automation platform 0
|
|
- Claud Short
- 5 years ago
- Views:
Transcription
1 Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V, ±0 V, -5 V, -0 ma, ± 0 ma). Low level (± 5 mv, ± 00 mv). Thermocouples (B, E, J,...). Temperature probes (Ni..., Pt...). The analog output bases are used to control analog fi eld devices such as various speed drives, proportional control valves, etc. The current or the voltage is proportional to the digital value defi ned by the user program. The outputs can be confi gured so that when the program stops the outputs either reset to zero or hold the last value received. This feature is useful during debugging since, if the outputs are set to Hold, the operation of the analog fi eld devices is not disturbed every time the program stops. In order to cover a wide range of applications, Momentum I/O bases offer the following functions in addition to A/D or D/A conversion: b Choice of input/output ranges (voltage, current, thermocouple, temperature probes). b Selection of number of channels used. b Cold junction compensation for thermocouple modules. b Broken wire detection (0 AAI 00 00, 0 AAI 0 00, 0 AAI 50 0). 5 Description 0 App analog I/O base units comprise on the front panel: Internal interface connector for the communication module or processor module. A locking and earth contact for the communication module or processor module. LED status indicators (the number of indicators will depend on the number of channels). Two connectors for the removable terminal blocks. 5 An earthing screw. A slot for the power strip Two screw holes for panel mounting. A protective cover. Connectors to be ordered separately: b removable screw or spring terminal blocks 0 XTS 00p 00. b to -row screw or spring bus bar 0 XTS 00p 0. Characteristics : pages / to / pages / and /9 page /9 pages /0 and /
2 Characteristics Characteristics of analog input bases Type of base units 0 AAI Number of inputs LEDs Format of data x differential imputs Ready (green) Full bits signed ( s complement) Protection Base and actuators Polarity inversion Ranges ± 0 VDC ± 5 VDC 0 ma ± 0 ma 5 VDC Input impedance kω >.000 > >.000 Error at 5 C % Error at 0 C % Resolution bits sign bipolar 5 bits unipolar Conversion times ms ms max. for input channels (. ms per input channel. ms) Error indication None Isolation Channel to channel VDC ± 00 for minute Field to ground VDC 500 for minute Communication adapter to VAC 500 for minute ground Common mode rejection Channel to ground 50 Hz or 00 VDC Crosstalk between channels db u 0 External power requirement Nominal VDC Limit values VDC 0. to. Current ma VDC EMC for industrial environment Immunity IEC surge on auxiliary power supply kv Emissions EN 500- Approvals UL, CSA, e pages / and /9 page /9 pages /0 and /
3 Characteristics (continued) Characteristics of analog input bases (continued) Type of base units 0 AAI AAI 50 0 Number of inputs x single-ended input x differential inputs Format of data Full bits signed ( s complement) Protection Base and actuators Polarity inversion Error indication None Ranges ± 0 V ± 5 V 0 ma ± 5 mv ± 00 mv Input impedance kω > 00 > 00 < 0.50 > 0000 > 0000 Error at 5 C 0.5 % FS 0.5 % FS 0.5 % FS ± µv ± µv Error at 0 C 0.5 % FS 0.5 % FS 0.5 % FS ± µv ± 9 µv Temperature drift (0 C) 0 PE / C 0 PE / C 0 PE / C PE (Full scale) 0 V 5 V ma Resolution bits sign bits sign bits 5 bits sign Filtering Low pass with cut-off frequency 0 khz Current source Pt00 ma 0.5 Ni00 ma 0.5 Pt000 ma 0.5 Ni000 ma 0.5 Update time ms.5 x n n = number of declared channels Error indication None 500 Potential isolation Channel to channel VDC None 00 Base power supply and ground VDC 500 for minute 500 for minute Channels to ground VAC 0 for minute 500 for minute Base power V ± 0 (voltage or current output) ± 0 (voltage or current output) Common mode Channel to ground V ± 00 DC, 50 AC Common mode Voltage between channels V 00 DC, 5 AC single phase or -phase or 50 AC single phase Common mode rejection Channel to ground 50 VAC at Hz or 00 VDC 5 db DC, 5 db AC 50 Hz, 55 db AC 0 Hz Between channels 0 db DC, 0 db AC 50 Hz, 0 db AC 0 Hz Serial mode rejection 5 db AC 50 Hz, 5 db AC 0 Hz Input protection Polarity inversion Operating voltage VDC Internal current ma VDC Power dissipation Typical W.95.5 Maximum W Fusing Internal A slow-blow A slow-blow External 500 ma fast-blow 500 ma fast-blow Agency approvals UL, e, CSA, FM Class I, Div. II pages / and /9 page /9 pages /0 and /
4 Characteristics (continued) Characteristics of analog output bases Type of base units 0 AAO AAO 9 00 Number of outputs x Format of data Full bits signed ( s complement) Protection Base and actuators Polarity inversion Ranges ± 0 V 0 0 ma ± 0 V 0 ma Load impedance kω minimum 0. maximum minimum 0. maximum Capacitive load µf < Error at 5 C % 0. PE 0. PE 0. PE 0. PE Error at 0 C % 0.5 PE 0. PE 0.5 PE 0.5 PE Temperature drift (0 C) 0 PE / C 0 PE / C 0 PE / C 0 PE / C Resolution bits sign Update time ms < Full scale Fail State 0 V in the range of ± 0V ma in the range of 0 0 ma Hold, reset to zero, reset to full scale Potential isolation Channel to channel None Base power supply and ground VDC 500 for minute Channels to ground VAC 500 for minute Outprotections Short-circuits in the voltage circuits, open in current polarity inversion Base power V ± 0 (voltage or current output) Common mode rejection VAC Hz or 50 DC channel to ground Operating voltage VDC Internal current Base ma VDC Actuators ma VDC Power dissipation Typical W 5. Maximum W.5 Internal fusing A, slow-blow Agency approvals UL, e, CSA pages / and /9 page /9 pages /0 and / 5
5 Characteristics (continued) Characteristics of discrete and analog I/O bases Type of base unit 0 AMM AMM Number of inputs and outputs x differential inputs x discrete inputs x analog outputs x discrete outputs Operating voltage VDC Internal current ma 00 typical (at VDC), 50 maximum (at VDC) Differential inputs for 0 AMM / maximum (at VDC) Conversion time 0 ms for all channels Conversion error ± 0 V ± 5 V 5 V ± 0 ma 0 ma 5 C % C % Resolution bits bits bits bits bits Conversion consistency % ± 0.0 ± 0.0 ± 0.0 ± 0.0 ± 0.0 Common mode voltage Input voltage starting at Ag ± V Common mode suppression db > 5 0 Overvoltage Voltage ranges V ± 0 solid state if voltage is V ± 50 dynamic max. 00 ms ± 0 solid state if voltage is V ± 50 dynamic max. 00 ms Overvoltage current ranges ma > Input resistance Ω M 50 Fail state Hold or reset to zero Discrete inputs Voltage VDC typical, 0 maximum typical Signal Type True high On Voltage VDC Off Voltage VDC Input current ma.5 minimum at state ( ma at operating voltage),. maximum at state 0 Input resistance kω. Response time ms. from 0 to state. from to state 0 Analog outputs Resolution bits for single-phase measuring range 0 0 ma, bits for -phase measuring range ± 0 V Conversion time ms for all channels Conversion error 5 C max. ± 0.5 % of upper measuring range value 0 C max. ± 0.0 % of upper measuring range value Output load u kω for voltage output, y 00 Ω for current output Discrete outputs Voltage VDC typical, 0 maximum Type Semiconductor Signal Type True high Current capacity per channel, per group, per module Leakage current ma VDC VDC On State Voltage drop VDC < A < 0.5 A Response time Off to On ms < 0. On to Off ms < 0. Output protection The outputs are protected against overload and short-circuit-circuiting Output indicator red LED per On output in the event of an overload or short-circuit-circuiting Error message Message I/O error on bus adapter if module is defective Max. Switching cycles 000/hr (inductive load A), 00/s (resistive load A), /s (filament load. W) Potential isolation Discrete input and output None Analog input to output None Analog input and output and to VAC 500 for minute operating voltage Operating voltage and all inputs and outputs from ground VAC 500 for minute Power dissipation Typical W.0 Maximum W.0 Agency approvals UL, e, CSA, FM Class I, Div. II UL, e, CSA pages / and /9 page /9 pages /0 and /
6 Characteristics (continued) Characteristics of discrete and analog I/O bases (continued) Type of base unit 0 ANR ANR 0 9 Number of inputs and outputs x analog inputs x discrete inputs x analog outputs x discrete outputs Operating voltage VDC, range Internal current ma VDC Analog inputs Resolution bit Input range VDC Input type Single-ended Conversion time 0.5 ms maximum for input channels Conversion error 0. 5 C for 0-0 VDC inputs Max input signal VDC 5 for voltage input Max temperature drift VDC 0 inputs Input resistance MΩ > for voltage inputs Discrete inputs Voltage VDC Confi guration groups of inputs Signal Type True high Minimum on voltage VDC > Maximum off voltage VDC < 5 Input current Minimum On ma Maximum Off ma Input voltage Range VDC... Surge VDC 5 peak for 0 ms Response time Off to On ms., On to Off ms. Analog outputs Resolution bit Output range VDC Conversion time ms.0 for all four channels Conversion error max. 0. % of upper measuring range 5 C Output load > kω VDC Fail state Hold or reset to zero Discrete outputs Voltage VDC 0-0 operating, 50 for ms maximum Type Solid State Switch Signal type True high Current capacity A 0.5 per point, per group, per module Leakage current ma 0 VDC Surge current A.5 for ms On state voltage drop VDC < 0.5 A current Response time Off to On ms. On to Off ms.05 Output protection The Outputs are protected against overload and short-circuiting Output indicator LED per point Potential isolation Discrete input to output None Analog input to output None Analog input and output to VAC 500 for minute. operating voltage Operating voltage and all inputs and outputs from ground VAC 500 for minute Power dissipation Typical W.0 Maximum W.0 Agency approvals UL, e, CSA pages / and /9 page /9 pages /0 and /
7 References Analog input bases Type of inputs Number of channels Ranges Reference Weight kg bits sign single-ended ± 5 V, ± 0 V, -0 ma 0 AAI bits sign, differential Pt 00, Pt 000, NI 00 thermocouples B, E, J, K, N, R, S, T, differential ± 5 V, ± 0 V, -5V ± 0 ma, -0 ma 0 AAI AAI AAI pp0 p0 Analog output bases Type of outputs Number of channels Ranges Reference Weight kg bits sign ± 0 V, 0-0 ma 0 AAO ± 0 V, -0 ma 0 AAO AAO pp 00 Discrete and analog I/O bases Type Ranges Reference Weight kg Inputs Outputs Inputs Outputs differential analog analogs bits sign bits discretes discretes 0.5 A ± 5 V, ± 0 V -5 V ± 0 ma -0 ma 0-0 ma ± 0 V VDC VDC 0 AMM AAM differential analog analogs bits sign bits discretes discretes 0.5 A ± 5 V, ± 0 V -5 V ± 0 ma -0 ma 0-0 ma ± 0 V VDC VDC 0 AMM analog bits analogs bits x discretes x discretes 0.5 A analog bits analogs bits x discretes x discretes 0.5 A 0-0 V 0-0 V 0 ANR VDC VDC ± 0 V ± 0 V 0 ANR VDC VDC Characteristics : pages / to / page /9 pages /0 and /
8 References (continued), dimensions, mounting 0 XTS XTS XTS 00 0 Accessories Description Composition Type of connection Terminal blocks Set of connectors row Reference Weight kg Screw 0 XTS Spring 0 XTS Bus Bar rows Screw 0 XTS 00 0 Spring 0 XTS 00 0 rows Screw 0 XTS Spring 0 XTS 00 0 rows Screw 0 XTS 00 0 Spring 0 XTS XTS Cable Grounding Rail Used to connect the cable shielding CER 00 0 XTS 00 0 High vibration environment clips Used to prewire the I/O base units. Requires screw or spring connection terminals 0 BDM XTS 00 0 Replacement parts Description Use Reference Weight kg Sheets of labels 0 front labels for Momentum modules 0 XTS CER 00 Set of codingand locating device For screw or spring connection terminals 0 XCP Dimensions, mounting 0 App Rail or panel mounting (),5 () 0 5 9,5 5 0 () holes for M screws, for panel mounting. () Equipment or enclosure. Characteristics : pages / to / pages /0 and / 9
9 Connections Connections of analog input bases and analog output bases 0 AAI AAI 0 00 Example of external wiring of -wire sensor Example of external wiring of -wire sensor Inl Inl Inl Inl Inl5 Inl Inl Inl Inl9 Inl0 Inl Inl Inl Inl Inl5 Inl V InU InU InU InU InU5 InU InU InU M- L InI InI InI InI InI5 InI InI InI VDC Return M L 500 ma fast-blow Return Agnd Agnd Agnd Agnd Agnd5 Agnd Agnd Agnd InI InI InI InI InI5 InI InI InI InU InU InU InU InU5 InU InU InU InU9 InU0 InU InU InU InU InU5 InU U I U VDC I Voltage input Current input Group of channels Internal wiring 0 AAI AAO 0/9 00 Example of external wiring of sensor Example of external wiring of -wire actuator V Return Fuse ( A slow-blow) Fuse ( A slow-blow) V Return IS RTD RTD IS InU InU IS RTD RTD IS IS RTD RTD IS InU InU InU InU IS RTD RTD IS InU InU L L 500 ma fast-blow OutI L OutI OutU L OutI OutI OutU L OutI OutI OutU L OutI OutI OutU M- L 0 ma fast-blow 50 ma M- L fast-blow U U U Group of channels Group of channels Internal wiring Internal wiring 0
10 Connections Connections of discrete and analog bases 0 AMM /AMM Example of external wiring of -wire sensor Example of external wiring of -wire actuator U IS U IS U IS U IS QV QI QV QI I I I I L () 5 ma () fast- Return blow U IS U IS U IS U IS QV QI QV QI I I I I L () 5 ma () fast- Return blow UI I UI I UI I UI I O O L 5 A fastblow UI I UI I UI I UI I O O L 5 A fastblow I U I -wire actuator U -wire actuator External bridge Group of channels Group of channels Internal wiring Internal wiring 0 AMM /AMM (continued) 0 ANR 0 90/9 Example of external wiring of digital sensor/actuator Example of mixed discrete and analog I/O sensor/actuator field wiring U IS U IS U IS U IS QV QI QV QI I I I I L () 5 ma () fast- Return blow I I I I I5 I I I AI AI AI AI AI5 AI M- L VDC Fuse () DGnd AGnd - Return UI I UI I UI I UI I O O L 5 A fastblow A0 A0 A0 A0 M- L VDC Fuse () - Return L M A fastblow Discrete output Nr.5 Analog input Nr. Analog output Nr. - Return Discrete input Nr. VDC PE Fuse () IN PE Out PE -wire sensor -wire actuator Group of channels Internal wiring () c V for 0 AMM , c V for 0 AMM () Depending on application, max 5 A.
S200 I/O System Units
S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationUSB-2404-UI Specifications
Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise
More informationNI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O
DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional
More informationCompactLogix 5370 L3 Control System
CompactLogix 5370 Controllers CompactLogix 5370 L1 Control System CompactLogix 5370 L2 Control System CompactLogix 5370 L3 Control System CompactLogix 5370 controllers provide scalable controller solutions
More informationCAN-IO Custom IO remote module
CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves
More information20 General technical data XI/ON
20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas
More informationQuantum I/O Modules. At a Glance. The following section provides information on the Quantum Input/Output (I/O) modules. What s in this Chapter?
Quantum I/O Modules At a Glance Introduction What s in this Chapter? The following section provides information on the Quantum Input/Output (I/O) modules. This chapter contains the following sections:
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationUniStream Uni-I/O Modules
UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,
More informationSCXI 8-Channel Isolated Analog Input Modules
SCXI 8-Channel Isolated Analog Input NI, NI SCXI-1120, NI SCXI-1120D 8 channels 333 ks/s maximum sampling rate Gain and lowpass filter settings per channel Up to 300 V rms working isolation per channel
More information6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)
Order number 6ES7331-1KF02-0AB0 Properties 8 inputs in 8 channel groups Programmable resolution at each channel group (12 bits + sign) Programmable measurement type per channel group: Voltage Current Resistance
More informationProgramming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.
6.9 Analog input module SM 331; AI 8 x RTD; (6ES7331-7PF01-0AB0) Cycle time extension due to wire-break monitoring The wire-break monitoring software function of the module is available in all operating
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More informationC1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications
Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationLCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans
LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationTemperature head transmitter itemp PCP TMT 181
Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationVersaPoint I/O Module
GFK-2012A March 2010 Module provides two-input channels for measuring signals from standard thermocouples. It supports thirteen different thermocouples types. In addition, it accepts linear voltage inputs
More informationAnalog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
More informationSpecifications. PCI Bus. Analog Input Input Characteristics
Specifications A This appendix lists the specifications of the NI 6034E/6035E/6036E. These specifications are typical at 25 C unless otherwise noted. The first section provides the specifications for the
More informationNI DAQPad -6020E Family Specifications
NI DAQPad -6020E Family Specifications This document lists the I/O terminal summary and specifications for the NI DAQPad-6020E family of devices. This family includes the following devices: NI DAQPad-6020E
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationMCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable
MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationFM 355 CONTROLLER MODULE
FM 355 CONTROLLER MODULE Function The FM 355 has 4 separate closed-loop control channels. The controllers display the features: Standard control structures (depending on the control structure selected,
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationGE Fanuc IC695ALG312. Rx3i PacSystem
GE Fanuc IC695ALG312 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695alg312 Rx3i PacSystem GE IP Isolated Thermocouple Input module 12 INPUTS 919-535-3180 sales@pdfsupply.com June 2008
More informationX20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622
X20(c)AI4622 1 General information The module is equipped with 4 inputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using
More informationAIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)
Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationLDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.
LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1
21-12-1 51169931-MTN1 Eaton Logic Controller ELCM TC Temperature s INSTRUCTION SHEET [Applicable Temperature modules] ELCM-TC4ANNN IL546E 2-1362-2 4A I-TC The ELCM-TC4ANNN measurement module supports 4
More informationICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More informationPlug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs
Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities
More information1769 Compact I/O Modules Specifications
Technical Document 1769 Compact I/O Modules Specifications Catalog Numbers 1769 Series Topic Page Summary of Changes 2 I/O Module Overview 2 Place Compact I/O Modules 4 Digital I/O Modules 5 Analog I/O
More informationProcess Multimeter DPM 79
NEW! Processmeter is a handheld, battery operated tool for measuring & simulation of electrical parameters. It has all the features of a digital multimeter (including the feature of RTD and TC) and it
More informationLOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION
EN K09LV LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION General Description The K09LV instrument is a three points galvanic insulator, with input on high sensitivity voltage, and active output.
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationIntroduction ISOLATED SIGNAL CONDITIONING can significantly increase
Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal
More informationIsolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or
More informationIsolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1
More informationAnalog Signal Conditioning Accessories
NI 64-channel multiplexer mv, V, current, and thermocouple inputs NI 8-channel simultaneous sample-and-hold mv, V inputs NI SC-2042-RTD 8-channel RTD/thermistor RTD, thermistor, mv, V inputs NI 8-channel
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationNI 6013/6014 Family Specifications
NI 6013/6014 Family Specifications This document lists the I/O terminal summary and specifications for the NI 6013/6014 family of devices. This family includes the following devices: NI PCI-6013 NI PCI-6014
More informationLDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.
LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. Its compact size, high efficiency, excellent reliability together with easy
More informationIsolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire
More informationDRG-SC Series Signal Conditioners
DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationNote The module converts unipolar and bipolar input signals
PROGRAMMABLE ANALOG SIGNAL CONVERTER THREE WAY GALVANIC ISOLATOR - 19 input scales - 7 output scales - 1 SPDT alarm contact - input/output isolation 3kV - auxiliary supply output for loop powered sensors
More information5069 Compact I/O Modules Specifications
Technical Data 5069 Compact I/O Modules Specifications Digital I/O Module Catalog Numbers 5069-IB16, 5069-IB16F, 5069-IB6F-3W, 5069-OB16, 5069-OB16F, 5069-OW4I, 5069-OX4I Analog I/O Module Catalog Numbers
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationTBX-68S Isothermal Terminal Block
INSTALLATION GUIDE TBX-68S Isothermal Terminal Block Contents Introduction This installation guide describes how to install and connect signals to the TBX-68S isothermal terminal block for use with the
More informationTxBlock-USB Transmitter
Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationPACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012
November 2012 PACSystems* RX3i Isolated RTD Input Module, 8 Channels, IC695ALG508-CA Isolated RTD Input module IC695ALG508 provides eight isolated differential RTD input channels. Each channel can be individually
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationIsolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series
Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationC520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters
C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationGeneral Specifications
General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O
More informationMCR-T-UI(/NC) MCR-T-UI-E(/NC)
MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring
More informationXIOC technology and networking modules
/ XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationCALYS 100. Field precision documenting multifunction calibrator
Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More information02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More information02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
More informationem4 em4 alert em4 alert 2G
em4 em4 alert em4 alert 2G Connect your equipment to the GPRS 2G network and get alerted by SMS or email Control your application by SMS Receive data reports by SMS or datalogs by email or FTP in.csv (Excel)
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationOPERATING INSTRUCTIONS NI Channel, 24-Bit, Universal Analog Input Module
OPERATING INSTRUCTIONS NI 9219 4-Channel, 24-Bit, Universal Analog Input Module These operating instructions describe how to use the National Instruments 9219. For information about installing, configuring,
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules
0 0 ma 0 V...0 ma JUMPFLEX Series Transducers / Relay and Optocoupler Modules JUMPFLEX Series A Complete Product Line is Available, Bringing Each Signal into Shape. The perfect match of housing and electronics
More informationIsolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors
More informationPROGRAMMABLE FIELD TEMPERATURE TRANSMITTER
Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance
More information1769 Compact I/O Modules Specifications
Technical Data 1769 Compact I/O Modules Specifications Catalog Numbers 1769 series Topic Page Available 1769 I/O Modules 4 Digital I/O Modules 6 Analog I/O Modules 7 Specialty I/O Modules 8 Module Specifications
More informationCALYS 75. Field documenting multifunction calibrator
Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.
More informationCALYS 50. Field multifunction calibrator for basic use
Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field
More informationISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits
ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in
More informationPFXLM4B01 D * * (1) (2) (3) (4)
Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationGeneral specifications and features
General specifications and features General specifications and features Table 1 General AC/DC/Relay DC/DC/Relay DC/DC/DC Order number 6ES7 212-1BE31-0XB0 6ES7 212-1HE31-0XB0 6ES7 212-1AE31-0XB0 Dimensions
More information