Lineator-HP High Performance model used where the highest power quality demands must be met

Size: px
Start display at page:

Download "Lineator-HP High Performance model used where the highest power quality demands must be met"

Transcription

1 LINEATOR TM Advanced Universal Harmonic Filter The LINEATOR Advanced Universal Harmonic Filter (AUHF) is a revolutionary advancement in the area of passive harmonic mitigation. No other device on the market can meet the stringent limits of IEEE Std 519 at an equivalent efficiency, size and cost. When your application calls for a truly cost effective harmonic solution, the LINEATOR AUHF is the logical choice. It provides Engineers with a standard off-the-shelf solution for what used to be a very challenging engineering problem. As industry evolves, so does the Lineator. Mirus has expanded it s product line to include two new Lineator models to meet your needs for those demanding applications. Revolutionary yreactor Design Better than 18-Pulse performance from standard 6-Pulse Variable Speed Drives Up to 3% more energy efficient than 18-Pulse or Active Front-end solutions and every bit as effective in treating harmonics Will meet IEEE 519 Std for both current and voltage distortion ABS Type Approved for marine applications `Wide Spectrum Harmonic Filter` that treats all harmonics generated by 3-phase diode or thyristor bridge rectifiers Lineator-HP High Performance model used where the highest power quality demands must be met Once again MIRUS leads the way in innovative passive harmonic mitigation solutions with the introduction of its new LINEATOR-HP model which is designed to offer <5%, THD(I). This level of harmonic mitigation matches Active Front end Drives (AFE S) and Active Filter (AF) performance without the high frequency harmonics introduced by these more expensive and complex solutions. With the addition of a new reactor design that allows for onsite reactor impedance optimization, current distortion levels of <5% THD(I) are achieved without introducing excessive voltage drop or VSD instability. Lineator-ED Extreme Duty model used when the operating conditions and environments can be harsh For extreme environments, such as excessive background voltage distortion (5% to 12% VTHD), high ambient (up to 55º C) or high elevation (above 3000 ft), Mirus now offers an extreme duty model for its Lineator AUHF. Our standard Lineator AUHF already outperforms any other competitive filter by guaranteeing performance when background voltage distortion is as high as 5%. In some applications however, such as marine vessels, drilling rigs and oil fields equipped with electrical submersible pumps (ESP s), existing voltage distortion levels will often exceed 5%. Also, when ambient temperature levels exceed 40º C or at higher elevations where the air is thinner, a more robust filter is required. The Lineator-ED model will meet this challenge. International Inc.

2 Design Considerations for Meeting Harmonic Limits in Variable Speed Drive Applications Features The most energy efficient harmonic solution for VSD s Meets harmonic limits for both land and marine VSD applications Guaranteed to meet IEEE Std 519 for both current and voltage distortion at the input terminals of the LINEATOR and PCC Wide Spectrum Harmonic Filter treats all major harmonics generated by VSD s and other 3-phase rectifier loads Total Demand Distortion (TDD) of the current at the LINEATOR input terminals will not exceed the limits as defined in Table 10.3 of IEEE Std 519 Compatible with engine driven generators thanks to the extremely low capacitive reactance, even at no load Suppresses overvoltages caused by commutation notching, capacitor switching and other fast changing loads Suitable for application on multiple VSD s provided only VSD s are connected Models available for AC Drives and DC Drives or other controlled rectifiers Benefits Saves energy by reducing upstream harmonic losses while operating at >99% efficiency Will not resonate with other power system components or attract line side harmonics Frees up system capacity by restoring VSD to near unity power factor Removal of harmonics improves overall system power factor True Power factor > 0.95 from 30% to 100% load Low capacitive reactance ensures generator compatibility Low capacitive reactance also eliminates the need for capacitor switching contactors (contactors are available upon request) The LINEATOR is a purely passive device consisting of a unique inductor combined with a relatively small capacitor bank. It's innovative design achieves reduction of all the major harmonic currents generated by VSD's and other similar 3-phase, 6-pulse rectifier loads. The resulting ITHD is reduced to <8% and and is now available in a model that achieves <5%. Although referred to as a filter, the LINEATOR exhibits none of the problems that plague conventional filters. Harmonic Distortion Reduction The filtering effectiveness of a trap filter is dependent upon the amount of harmonics present at untuned frequencies as well as the residual at the tuned frequency. To obtain performance better than 15% ITHD, multiple tuned branches are often required. Other broadband filters require relatively large capacitor banks (2 to 3 times more than Lineator) to achieve reasonable performance. Harmonics from other sources As a parallel connected device, the conventional trap filter has no directional properties. It therefore, can easily be overloaded by attracting harmonics from upstream non-linear loads. The LINEATOR, on the other hand, will present a high impedance to line side harmonics eliminating the possibility of inadvertent importation and overloading. System Resonance At frequencies below its tuned frequency, a conventional filter will appear capacitive. This capacitance has the potential of resonating with the power systems natural inductance. When a filter is tuned to a higher order harmonic, such as the 11th, it could easily resonate at a lower harmonic frequency, such as the 5th or 7th. Even the LCL passive filters required for low harmonic AFE Drives or parallel Active Harmonic Filters are susceptible to this problem. The natural resonance frequency of the LINEATOR is below that of any predominant harmonic, therefore inadvertent resonance is avoided. Capacitive Reactance and Leading Power Factor The large capacitor banks in trap filters and competing broadband filters present a high capacitive reactance to the system, especially under light loads. On weak power systems, this can raise voltages or cause excitation control problems in generator applications. To address this, some filter manufacturers offer mechanisms for switching out the capacitors under light loads, increasing cost and complexity. This is not necessary for the LINEATOR because even under no load conditions, it s capacitive reactance (kvar) remains below 15% of its kva rating. This ensures compatibility with engine generators, without the need to switch out capacitors. Competitor Filter kvar Curve (Typical) LINEATOR AUHF kvar Curve (Typical) Acceptable Operating Range Generator Reactive Power Capability Curve

3 Compare Performance! The LINEATOR outperforms all other forms of VSD harmonic solutions. By choosing the LINEATOR you have selected a filter that: performs in Real World environments even with background voltage distortion and voltage imbalance lowers operating costs by being highly efficient is compatible with engine generators and incorporates a low capacitive reactance design has a simple and compact design to reduce footprint and ensure reliability can be computer modeled to provide up front assurance of meeting harmonic limit standards such as IEEE Std 519, ABS and other marine certifying bodies is factory performance tested under actual VSD loading Outperforms 18-P Solutions As background voltage distortion increases, the harmonic mitigating performance of the 18-Pulse VSD degrades much quicker than the 6-Pulse / LINEATOR combination. This demonstrates that the LINEATOR AUHF will not attract harmonic currents as other non-linear loads distort the applied voltage waveform. LINEATOR is the only harmonic solution that guarantees performance even in heavily distorted environments. There is little degradation in harmonic mitigating performance of the 6-Pulse / LINEATOR combination as voltage imbalance increases. The 18-Pulse solution, on the other hand, degrades dramatically because harmonic cancellation due to phase shifting becomes much less effective with 3-phase voltage imbalance. Efficiency Comparison The unique design of the AUHF produces extremely low losses. It s operating efficiency therefore is much higher than competitive filters. The graphs below show typical losses and efficiencies for AUHF and two competitors. (AUHF is available in sizes up to 3500HP. Since competitor maximum sizes are only 600HP and 900HP, the chart range has been set at 1000HP) FL Losses (W) Efficiency at FL Filter Size (HP) Lineator AUHF Competitor1 Competitor2 100% 99% 98% 97% 96% Harmonic Filter Comparison - Typical Losses Harmonic Filter Comparison - Efficiency 95% Filter Size (HP) Lineator AUHF Competitor1 Competitor2 Improves VSD Performance VSD Input Current Waveform and Spectrum with no reactor. The 6-Pulse VSD / LINEATOR combination has 2% to 3% higher efficiency than the 18-Pulse solution over the entire operating range. (Efficiency shown is for a system that includes motor/gen set load, VSD, and harmonic mitigation equipment). When compared to an 18-Pulse VSD, a 400HP AUHF/VSD will save more than $3,000 in annual operating costs when averaging 75% loading at $0.07/kWHr. VSD Input Current Waveform and Spectrum with AC reactor. VSD Input Current Waveform and Spectrum with LINEATOR AUHF.

4 'Performance Guarantee' MIRUS guarantees that the LINEATOR AUHF will perform as advertised to reduce harmonic distortion caused by AC Variable Speed Drives and other non-linear loads equipped with 3-phase, 6-pulse, diode bridge rectifiers. A properly selected and installed LINEATOR will: Reduce Current Total Harmonic Distortion (ITHD), measured at the LINEATOR input terminals at full load, to: (i) <8% when background voltage distortion is <5% and voltage imbalance is <3% (ii) <5% when short circuit ratio (Isc/IL), as defined by IEEE Std 519, is <20 and when background voltage distortion is <0.5% and voltage imbalance is <1% (iii) Reduce Current Total Demand Distortion (ITDD), measured at the LINEATOR input terminals over its entire operating range, to levels defined in Item (i) above. ITDD is defined as the ratio of ITHD divided by the full load current (peak demand current) of the LINEATOR. (iv) Minimize the contribution to Voltage Harmonic Distortion of all VSD s equipped with the LINEATOR to <5% total and <3% for individual harmonics, as defined by IEEE Std (v) NOT become overloaded by other upstream harmonic sources. (vi) NOT resonate with other power system components. (vii) NOT have compatibility problems with engine generator sets properly sized for the load. The Harmonics & Energy (H&E ) Lab The Harmonics & Energy (H&E) Lab at MIRUS International Inc. provides the unique ability to test our products under real world non-linear load conditions. We also conduct compatibility testing with all major VSD manufacturers' products to ensure a trouble-free installation. Every LINEATOR is factory tested under VSD load to ensure our performance guarantee is met. No other manufacturer provides this level of testing whether they offer a passive filter, multi-pulse or active solution. SOLV Harmonic Analysis Software MIRUS offers proprietary software called Simulation of LINEATOR / VFD (SOLV). SOLV is a powerful and unique computer simulation program that will calculate current and voltage distortion levels based on your load requirements. By simply entering some basic information about your source and VSD system, you can generate very useful reports such as, an IEEE 519 Compliance Report. In addition to the accurate reports, you can print a single line representation of your system along with voltage and current waveforms and spectrums. MIRUS' SOLV will help you find the right solution for your VSD application without the need of a costly harmonic study. It can be downloaded at mirusinternational.com

5 Lineator Applications Oil & Gas Industry Application of ASD s in the Oil and Gas Industry continues to grow at a rapid pace. This includes Electrical Submersible Pumps (ESP s), Top Drives and Mud Pumps on Drilling packages, Compressors, etc. Without harmonic mitigation, very serious consequences can result. Although not conclusively proven, high levels of harmonic distortion has been considered as a possible cause of off-shore drilling rig disasters in the Gulf of Mexico and the North Sea. Apply LINEATOR anywhere Variable Speed Drives and 6-Pulse Rectifiers are used Water & Waste Water Although 18-Pulse ASD s are commonly used in the Water and Waste Water applications, there is a much better solution available. Lineator paired with a 6-Pulse ASD provides better harmonic mitigation performance especially if the supply has even low levels of voltage imbalance. And the Lineator s much lower losses can result in thousands of dollars in energy savings annually. HVAC Systems In many commercial buildings, the chillers, pumps and fan systems required for cooling represent a very large component of the building s electrical load. For today s Green Building designs, ASD s are being used on all of this equipment leading to harmonic distortion issues. To address this concern, Lineators are being used to eliminate harmonics without sacrificing any of the energy savings advantages of the ASD. Marine Vessels Due to the serious consequences of high harmonic distortion, the American Bureau of Shipping (ABS), Det Norse Veritas (DnV) and all other Marine Certifying bodies have mandatory harmonic limits that must be met in order to attain certification. Since ASD s are now common-place on thrusters and main propulsion systems, these limits cannot be met without effective harmonic mitigation. The Lineator will meet these limits without introducing the troublesome high frequency harmonics associated with active solutions such as Active Front-end Drives and Active Harmonic Filters. Condition Based Maintenance Tool When InSight is integrated into your system it provides essential health and performance information to the operator to let them know whether the equipment is operating within safe limits. For instance, should power quality or environmental conditions affect the normal operation of an Adjustable Speed Drive equipped with a Lineator Harmonic Filter and InSight monitor, operators can be notified of the filter's condition so that proactive action can be taken, if necessary. Oil and Gas industry Water and Waste Water Irrigation systems HVAC systems Mining operations Marine vessels Printing presses Elevators and escalators Pulp and paper processing Induction furnaces Industrial rectifiers. Welding operations Stay in touch with your equipment, locally or remotely Mirus designed InSight as a web-based monitoring system allowing easy access via any web browser or by adding a touchscreen display at the equipment.

6 Rating Tables: (type D Lineator) [1] Specifying the LINEATOR HP for applications with standard 6-Pulse VFD's provides end-users with low harmonic drive systems that results in 20% to 30% less capital costs than other solutions Motor Size Lineator Rating (3-Phase) 208, 240V (60Hz) 400, 440V (50Hz) Input Amps Standard Enclosure Enhanced Enclosure Standard Enclosure Enhanced Enclosure HP kw 220/ 380/ 415/ 208V 240V 400V 440V Output Case Weight Case Weight Case Weight Case Weight 60Hz 50/60Hz 50Hz 50Hz kw Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] SU1 65 [30] SU1-E 75 [34] 58 [26] 68 [31] [35] 86 [39] SU1 67 [30] SU1-E 77 [35] [36] 80 [36] 78 [35] 88 [40] SU2-E SU2 117 [53] 127 [58] 90 [41] 100 [45] [63] 148 [67] 118 [54] SU2-E 128 [58] [70] 164 [74] SU2 130 [59] 140 [64] [86] SU3-E 199 [90] 142 [65] 152 [69] SU3 253 [115] 263 [119] 154 [70] 164 [74] [125] 333 [151] 186 [84] SU3-E 196 [88] [143] SU4-E 337 [153] SU3 218 [99] 228 [103] [148] 399 [181] 304 [138] 314 [142] SU4 442 [201] 516 [235] 323 [147] SU4-E 414 [188] [213] -E 542 [246] SU4 345 [156] 434 [197] [251] 627 [285] 365 [166] -E 469 [213] [189] 514 [234] [262] MT4-E 600 [273] [266] 670 [305] MT4 800 [363] 1006 [456] [374] LT1-E 1031 [467] [415] 1121 [508] LT [499] LT2-E 1176 [535] [771] 1839 [834] LT [854] 1954 [886] [871] LT3-E 2054 [931] [884] 2084 [945] [1118] 2564 [1163] LT [1167] 2958 [1245] [1236] 3408 [1549] [1299] HT2-E 3548 [1613] [1635] 3690 [1677] [1703] 3840 [1745] HT [1749] 4376 [1943] [1808] 4506 [2048] [1850] HT3-E 4600 [2088] [2111] 4750 [2157] HT [2270] 5100 [2315] [2372] [2520] Motor Size Lineator Rating (3-Phase) 480V (60Hz) 600V (60Hz), 690V (50-60Hz) Input Amps Standard Enclosure Enhanced Enclosure Standard Enclosure Enhanced Enclosure HP kw 460/ 575/ 660/ 480V 600V 690V Output Case Weight Case Weight Case Weight Case Weight 60Hz 60Hz 50/60Hz kw Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] [26] 68 [31] 57 [26] 67 [30] SU1 67 [30] SU1-E 77 [35] 67 [30] SU1-E 77 [35] [35] 88 [40] SU1 77 [35] 87 [39] [41] 100 [45] 86 [39] 96 [44] [54] 128 [58] 98 [45] 128 [58] [59] SU2-E 140 [64] 125 [57] SU2-E 135 [61] SU2 142 [65] 152 [69] 137 [62] 147 [67] [70] 164 [74] SU2 149 [68] 159 [72] [84] 196 [89] 184 [83] 196 [89] [99] SU3-E 228 [103] 206 [94] SU3-E 216 [98] SU3 304 [138] 314 [142] 298 [135] 308 [140] [147] 333 [151] SU3 315 [143] 325 [147] [156] SU4-E 419 [191] 345 [156] SU4-E 419 [191] SU4 365 [166] 439 [200] SU4 365 [166] 439 [200] [189] -E 489 [222] 415 [189] -E 489 [222] [262] 640 [290] 578 [262] 640 [290] [266] MT4-E 695 [316] 585 [266] MT4-E 695 [316] [363] 1006 [456] 780 [354] 1006 [456] MT4 825 [374] 1031 [467] MT4 805 [365] 1031 [467] [415] LT1-E 1121 [508] 915 [415] LT1-E 1121 [510] LT [634] 1476 [670] LT [634] 1476 [670] [771] LT2-E 1839 [834] 1650 [748] LT2-E 1740 [789] [854] 1954 [886] 1805 [819] 1852 [842] LT [871] 2054 [931] LT [854] 2054 [932] [884] LT3-E 2084 [945] 1915 [869] LT3-E 2064 [936] [1118] 2564 [1163] 2331 [1057] 2515 [1141] LT [1167] 2958 [1245] LT [1121] 2855 [1298] [1236] 3408 [1549] 2609 [1186] 2999 [1363] [1299] HT2-E 3548 [1613] 2782 [1265] HT2-E 3172 [1442] [1635] 3690 [1677] 3540 [1606] 3620 [1642] [1703] 3840 [1745] 3702 [1679] 3800 [1724] HT [1749] 4376 [1943] HT [1723] 3875 [1758] [1808] 4506 [2048] 3945 [1789] 4250 [1928] [1850] HT3-E 4600 [2088] 4015 [1821] HT3-E 4340 [1969] [2111] 4750 [2157] 4600 [2087] 4750 [2155] HT [2270] 5100 [2315] HT [2243] 5100 [2313] [2372] 5180 [2350] [2520] 5490 [2490] 1. For type T Lineator use enclosure and weights from the next size up.

7 Cap. Fuse Cap. Fuse Cap. Fuse Cap. Fuse Cap. Fuse Cap. Fuse A Dimensions A B E B E FRONT VIEW 1.00 TYP. D C F RIGHT SIDE VIEW 1.00 TYP., MT4, LT ENCLOSURE A1 B1 C1 A2 B2 C2 A3 B3 C3 FRONT VIEW E0P PANEL/BASE MOUNT Ordering Information Model Motor Line Horsepower Voltage Advanced Universal Harmonic Filter D C F FRONT VIEW RIGHT SIDE VIEW BACK VIEW SU1, SU2, SU3 ENCLOSURE CASE STYLE RIGHT SIDE VIEW 5 to 3500 H G FRONT VIEW E0 OPEN STYLE Frequency RIGHT SIDE VIEW DIMENSIONS - inches [mm] SU4 ENCLOSURE Load Type HT ENCLOSURE A1 B1 C1 A2 B2 C2 A3 B3 C3 FRONT VIEW E0M MODULAR Enclosure Type VVV Hz L En O [1] D Diode Bridge Rectifier [2] 440 T Thyristor Bridge Rectifier 690 (VAC) E0 No Enclosure Base Mount Only (5 to 1400HP) E0P No Enclosure Panel/Wall Mountable (5 to 125HP) E0M Modular (Caps. shipped Loose) (400 to 3500HP) E1 Nema 3R [IP23] Ventilated Enclosure (5 to 3500HP) CAPACITOR BOARD (Supplied loose) Standard Enhanced A B C D E F G H SU1 SU1-E [597] [286] 8.75 [222] [286] 8.00 [203] 9.00 [229] [330] 9.00 [229] SU2 SU2-E [749] [336] [260] [324] 9.00 [229] [254] [406] [279] SU3 SU3-E [864] [514] [336] [406] [445] [330] [508] [457] SU4 SU4-E [1016] [559] [470] [584] [508] [508] -E [1143] [661] [534] [635] [546] [483] MT4 MT4-E [1308] [813] [648] [749] [597] [597] LT1 LT1-E [1499] [1003] [762] [864] [610] [813] LT2 LT2-E [1677] [1118] [864] [965] [660] [915] LT3 LT3-E [1905] [1232] [991] [1092] [699] [1041] HT2 HT2-E [1981] [1486] [1295] [1428] [1333] [1289] HT3 HT3-E [2134] [1740] [1499] [1638] [1587] [1492] AUHF HP VV 1. D type AUHF is suitable for standard diode bridge and diode/scr precharged front-end VSD s. 2. T type AUHF is suitable for DC drives, Current Source Inverters and other controlled rectifier loads. A A B E FRONT VIEW B E FRONT VIEW C D F RIGHT SIDE VIEW D C 6.50 F Typ. RIGHT SIDE VIEW BACK VIEW Optional E Nema 3R [IP23] Enhanced HP High Performance ED Extreme Duty MD Marine Duty General Specifications: HP / kw RATING: Available for motor/drive system sizes up to 3500HP / 2600kW VOLTAGE: Standard voltages up to 690V, 3-phase FREQUENCY: 50 or 60Hz OVERLOAD CAPABILITY: Suitable for overload of 150% for 60 seconds every 10 minutes HARMONICS TREATED: 5th, 7th, 11th, 13th,... K-FACTOR SUITABILITY: Up to 20 INPUT K-FACTOR: Reduced to <1.5 INPUT CURRENT DISTORTION: <8% at full load [<5% available] SHORT CIRCUIT RATING: 100kAIC NO LOAD CAPACITIVE REACTANCE (kvar) LEVELS: 5 to 75HP 15 to 20% 100 to 3500HP 10 to 15% EFFICIENCY: >99% ELEVATION: 3300ft [1000m] above sea level VENTILATION: Convection air cooled ENCLOSURE: NEMA 3R [IP23] Paint: Polyester powder coated Color: ANSI 61 Grey OPTIONAL: Nema 3R [IP23] Enhanced DNV or Lloyds Certification Lineator-ED Selection Curve BACKGROUND VTHD Typical Lineator Configurations Standalone VSD System Input TM LINEATOR AUHF VSD 15% 12% 10% 5% 0 0 VSD System with Bypass* Input ELEVATION Extreme Duty Lineator Standard Lineator 40 [104 ] AMBIENT TEMPERATURE TM LINEATOR AUHF VSD x 1000 m 4500 m [3000 ft] [15000 ft] C [122 ] [131 F] Multiple VSD System Input TM LINEATOR AUHF VSD VSD VSD MOTOR MOTOR MOTOR MOTOR MOTOR R * When the VSD requires a bypass, the LINEATOR does not require bypassing. It will provide Reduce Voltage Reactor Start which gives a smooth ramp to full speed with built in ramp and full load power factor correction..

8 Expect better. Call us. To discuss how MIRUS can help you meet your power quality challenges, contact us at our head office: MIRUS International Inc. 31 Sun Pac Blvd. Brampton, Ontario Canada L6S 5P6 Tel: (905) Fax: (905) Toll-Free: TO MIRUS ( ) R International Inc. Harmonic and Energy Solutions Real-world performance for real-world loads. C Mirus International Inc. All specifications subject to change without notice. AUHF-PS01-A3 Effective: March 2014

9 MIRUS International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 THE LINEATOR TYPICAL SPECIFICATION Advanced Universal Harmonic Filter (AUHF) PART 1 GENERAL 1.1 All PWM AC Variable Frequency Drives of [ 30 ] hp and above shall be equipped with harmonic mitigation equipment to prevent power system problems resulting from high levels of harmonic distortion..1 The harmonic mitigation equipment and all of its components shall be manufactured and tested in accordance with the latest applicable standards of UL, CSA and NEMA..2 Demonstration of compatibility between the harmonic mitigation equipment and the VFD must be available upon request..3 Harmonic mitigation equipment shall be warranted to be free of defects in materials and workmanship for a period of 3 years from the date of shipment..4 Factory Performance Testing: Manufacturer must be capable of factory testing for harmonic mitigating performance and energy efficiency under actual variable frequency drive loads. A detailed description of the program and a sample test report must be provided at time of quotation..5 Subject to compliance with all of the contract documents and specifications, the acceptable product and manufacturer is: LINEATOR AUHF, by MIRUS International Inc. (905) , Toll Free: (888) PART 2 - PRODUCT 2.1 Key Requirements:.1 The harmonic mitigation equipment shall treat all of the characteristic low frequency harmonics generated by a 3- phase, diode bridge rectifier load (5 th, 7 th, 11 th, 13 th, etc.)..2 The characteristic harmonics shall be suppressed without the need for individual tuning or the requirement to phase shift against other harmonic sources..3 Harmonic mitigation shall be by passive inductor/capacitor network. Active electronic components shall not be used..4 Power factor shall be.98 lagging to.95 leading in operating range from full to half load..5 To ensure compatibility with engine generators, the harmonic mitigation equipment must never introduce a capacitive reactive power (KVAR), which is greater than 20% of its kva rating..6 The harmonic mitigation equipment shall not resonate with system impedances or attract harmonic currents from other harmonic sources..7 The harmonic mitigation equipment in combination with the Variable Frequency Drive shall meet all requirements as outlined in the 1992 edition of IEEE std 519 for individual and total harmonic voltage and current distortion. The Point of Common Coupling (PCC) for all voltage and current harmonic calculations and measurements shall be the input terminals to the harmonic mitigation equipment..8 Total Harmonic Voltage Distortion (THVD) shall meet the requirements of Table 10.2 of IEEE std 519 by not exceeding 5% and by limiting the individual harmonic voltage distortion to less than 3%. These limits shall apply while operating on either utility supply or generator supply when applicable. The harmonic mitigation equipment vendor shall not be responsible for pre-existing voltage distortion caused by other harmonic sources..9 Total Demand Distortion (TDD) of the current at the input terminals of the harmonic mitigation equipment shall not exceed the limits as defined in Table 10.3 of IEEE std 519. For Isc/IL ratio < 20, TDD must be less than 5%. For all other Isc/IL ratios, the TDD must not exceed 8% even when Table 10.3 allows for more relaxed limits. For singlephase applications, the TDD must not exceed 12%..10 The full load efficiency of the harmonic mitigation equipment / VFD combination shall be greater than 96%. The harmonic mitigation equipment itself shall have efficiency no less than 99%. 2.2 Basic Requirements:.1 All wiring shall be copper..2 Insulation class: 220 C system. Temperature rise: 130 C.3 Anti-vibration pads shall be used between the reactor or transformer core and the enclosure..4 Ventilated, sprinkler proof NEMA-3R enclosure. 2.3 Options:.1 Submit for approval before shipment certified production test results with serial numbers for harmonic mitigation performance and energy efficiency under actual variable frequency drive loading. PART 3 - EXECUTION 3.1 Installation.1 The harmonic mitigation equipment shall be handled, stored and installed in accordance with the manufacturer's recommended installation practices as found in the installation, operation, and maintenance manual. Installation shall comply with all applicable codes. 3.2 Acceptance.1 [OPTION] Harmonic compliance shall be verified with onsite field measurements of both the voltage and current harmonic distortion at the input terminals of the harmonic mitigating equipment with and without the equipment operating. A recording type Fluke 41 or equivalent harmonics analyzer displaying individual and total harmonic currents and voltages must be utilized. Mirus International Inc. [ ] TO MIRUS AUHF-TS001-A3

10 MIRUS International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 THE LINEATOR TECHNICAL DATA Advanced Universal Harmonic Filter (AUHF) Enclosed GENERAL SPECIFICATIONS: RATING For motor/drive system sizes INPUT CURRENT < Full Load 5HP(4kW) to 3500HP(2600kW) DISTORTION VOLTAGE Standard voltages up to 690V EFFICIENCY > 99% FREQUENCY 60Hz (50Hz available) ELEVATION 3300ft [1000m] above sea level OVERLOAD CAPABILITY Suitable for overload of 150% for 60 VENTILATION Convection air cooled seconds every 10 minutes AMBIENT TEMPERATURE 104 Deg F [40 Deg C] HARMONICS TREATED All harmonics 5 th and higher WINDING MATERIAL Copper K-FACTOR SUITABILITY Up to 20 (Reduced to <1.5 on input of AUHF) ENCLOSURE Type: TYPE-3R, Colour: ANSI 61 Grey Paint: Polyester powder coated Wall Mtg Capability: 5 to 200HP MAXIMUM CAPACITIVE REACTIVE N.L. < 20% of rated input current OPTIONS: TYPE-3R Enhanced Outdoor Ventilated Enclosure, Fan Cooling ( HP), Hinged Doors ( HP) Motor Size Lineator Rating (3-Phase) 480V (60Hz) 600V (60Hz), 690V (50-60Hz) Input Amps Standard Enclosure Enhanced Enclosure Standard Enclosure Enhanced Enclosure HP kw 460/ 575/ 660/ 480V 600V 690V Output Case Weight Case Weight Case Weight Case Weight 60Hz 60Hz 50/60Hz kw Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] [26] 68 [31] 57 [26] 67 [30] SU1 67 [30] SU1-E 77 [35] 67 [30] SU1-E 77 [35] [35] 88 [40] SU1 77 [35] 87 [39] [41] 100 [45] 86 [39] 96 [44] [54] 128 [58] 98 [45] 128 [58] [59] SU2-E 140 [64] 125 [57] SU2-E 135 [61] SU2 142 [65] 152 [69] 137 [62] 147 [67] [70] 164 [74] SU2 149 [68] 159 [72] [84] 196 [89] 184 [83] 196 [89] [99] SU3-E 228 [103] 206 [94] SU3-E 216 [98] SU3 304 [138] 314 [142] 298 [135] 308 [140] [147] 333 [151] SU3 315 [143] 325 [147] [156] SU4-E 419 [191] 345 [156] SU4-E 419 [191] SU4 365 [166] 439 [200] SU4 365 [166] 439 [200] [189] -E 489 [222] 415 [189] -E 489 [222] [262] 640 [290] 578 [262] 640 [290] [266] MT4-E 695 [316] 585 [266] MT4-E 695 [316] [363] 1006 [456] 780 [354] 1006 [456] MT4 825 [374] 1031 [467] MT4 805 [365] 1031 [467] [415] LT1-E 1121 [508] 915 [415] LT1-E 1121 [510] LT [634] 1476 [670] LT [634] 1476 [670] [771] LT2-E 1839 [834] 1650 [748] LT2-E 1740 [789] [854] 1954 [886] 1805 [819] 1852 [842] LT [871] 2054 [931] LT [854] 2054 [932] [884] LT3-E 2084 [945] 1915 [869] LT3-E 2064 [936] [1118] 2564 [1163] 2331 [1057] 2515 [1141] LT [1167] 2958 [1245] LT [1121] 2855 [1298] [1236] 3408 [1549] 2609 [1186] 2999 [1363] [1299] HT2-E 3548 [1613] 2782 [1265] HT2-E 3172 [1442] [1635] 3690 [1677] 3540 [1606] 3620 [1642] [1703] 3840 [1745] 3702 [1679] 3800 [1724] HT [1749] 4376 [1943] HT [1723] 3875 [1758] [1808] 4506 [2048] 3945 [1789] 4250 [1928] [1850] HT3-E 4600 [2088] 4015 [1821] HT3-E 4340 [1969] [2111] 4750 [2157] 4600 [2087] 4750 [2155] HT [2270] 5100 [2315] HT [2243] 5100 [2313] [2372] 5180 [2350] [2520] 5490 [2490] Mirus International Inc. [ ] TO MIRUS AUHF-S001-C6 Page 1 of 2

11 MIRUS International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 THE LINEATOR TECHNICAL DATA Advanced Universal Harmonic Filter (AUHF) Enclosed Motor Size Lineator Rating (3-Phase) 208, 240V (60Hz) 400, 440V (50Hz) Input Amps Standard Enclosure Enhanced Enclosure Standard Enclosure Enhanced Enclosure HP kw 220/ 380/ 415/ 208V 240V 400V 440V Output Case Weight Case Weight Case Weight Case Weight 60Hz 50/60Hz 50Hz 50Hz kw Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] Style lbs [kg] [1] SU1 65 [30] SU1-E 75 [34] 58 [26] 68 [31] [35] 86 [39] SU1 67 [30] SU1-E 77 [35] [36] 80 [36] 78 [35] 88 [40] SU2-E SU2 117 [53] 127 [58] 90 [41] 100 [45] [63] 148 [67] 118 [54] SU2-E 128 [58] [70] 164 [74] SU2 130 [59] 140 [64] [86] SU3-E 199 [90] 142 [65] 152 [69] SU3 253 [115] 263 [119] 154 [70] 164 [74] [125] 333 [151] 186 [84] SU3-E 196 [88] [143] SU4-E 337 [153] SU3 218 [99] 228 [103] [148] 399 [181] 304 [138] 314 [142] SU4 442 [201] 516 [235] 323 [147] SU4-E 414 [188] [213] -E 542 [246] SU4 345 [156] 434 [197] [251] 627 [285] 365 [166] -E 469 [213] [189] 514 [234] [262] MT4-E 600 [273] [266] 670 [305] MT4 800 [363] 1006 [456] [374] LT1-E 1031 [467] [415] 1121 [508] LT [499] LT2-E 1176 [535] [771] 1839 [834] LT [854] 1954 [886] [871] LT3-E 2054 [931] [884] 2084 [945] [1118] 2564 [1163] LT [1167] 2958 [1245] [1236] 3408 [1549] [1299] HT2-E 3548 [1613] [1635] 3690 [1677] [1703] 3840 [1745] HT [1749] 4376 [1943] [1808] 4506 [2048] [1850] HT3-E 4600 [2088] [2111] 4750 [2157] HT [2270] 5100 [2315] [2372] [2520] SU1, SU2, SU3 ENCLOSURE SU4 ENCLOSURE, MT4, LT HT ENCLOSURE CASE STYLE ENCLOSURE DIMENSIONS - inches [mm] Standard Enhanced A B C D E F G H SU1 SU1-E [597] [286] 8.75 [222] [286] 9.00 [229] 8.50 [216] [305] 9.00 [228] SU2 SU2-E [749] [336] [260] [324] [279] [254] [406] 11.00[279] SU3 SU3-E [864] [514] [336] [406] [457] [330] [508] 18.00[457] SU4 SU4-E [1016] [559] [470] [584] [508] [508] -E [1143] [661] [534] [635] [546] [483] MT4 MT4-E [1308] [813] [648] [749] [597] [597] LT1 LT1-E [1499] [1003] [762] [864] [610] [813] LT2 LT2-E [1677] [1118] [864] [965] [660] [915] LT3 LT3-E [1905] [1232] [991] [1092] [699] [1041] HT2 HT2-E [1981] [1486] [1295] [1428] [1333] [1289] HT3 HT3-E [2134] [1740] [1499] [1638] [1587] [1492] Notes: 1. Approximate Values. 2. Specifications are subject to change without notice. 3. Lineator sizing is by standard motor horsepower and kw ratings. Each is capable of supplying the larger of the two ratings. 4. Cable entry is from left or right side only unless otherwise indicated. 5. For additional information refer to: Typical Specifications, Internal Layout and Connection Diagrams. Mirus International Inc. [ ] TO MIRUS AUHF-S001-C6 Page 2 of 2

12 MIRUS International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 SPECIFICATION PWM Variable Frequency Drive (VFD) Typical Harmonic Specification PART 1 - GENERAL 1.1 All PWM AC Variable Frequency Drives of [ 30 ] hp and above shall be equipped with harmonic mitigation equipment to prevent power system problems resulting from high levels of harmonic distortion..1 The harmonic mitigation equipment and all of its components shall be manufactured and tested in accordance with the latest applicable standards of UL, CSA and NEMA..2 Demonstration of compatibility between the harmonic mitigation equipment and the VFD must be available upon request..3 Harmonic mitigation equipment shall be warranted to be free of defects in materials and workmanship for a period of 3 years from the date of shipment...4 Factory Performance Testing: Manufacturer must be capable of factory testing for harmonic mitigating performance and energy efficiency under actual variable frequency drive loads. A detailed description of the program and a sample test report must be provided at time of quotation..5 Subject to compliance with all of the contract documents and specifications, the following manufacturers and products are acceptable:.1 MIRUS International Inc. LINEATOR Advanced Universal Harmonic Filter (AUHF).2 MIRUS International Inc. LINEATOR Single Phase Universal Harmonic Filter (SUHF).3 VFD with an 18-pulse rectifier as manufactured by ABB, Allen Bradley, Cutler Hammer, Robicon, or Toshiba. PART 2 - PRODUCT 2.1 Key Requirements:.1 The harmonic mitigation equipment shall treat all of the characteristic low frequency harmonics generated by a 3-phase, diode bridge rectifier load (5 th, 7 th, 11 th, 13 th, etc.)..2 The characteristic harmonics shall be suppressed without the need for individual tuning or the requirement to phase shift against other harmonic sources..3 Harmonic mitigation shall be by passive inductor/capacitor network or internal phase shifting transformer. Active electronic components shall not be used..4 Power factor shall be.98 lagging to.95 leading in operating range from full to half load..5 To ensure compatibility with engine generators, the harmonic mitigation equipment must never introduce a capacitive reactive power (KVAR) which is greater than 20% of its kva rating..6 The harmonic mitigation equipment shall not resonate with system impedances or attract harmonic currents from other harmonic sources..7 The harmonic mitigation equipment in combination with the Variable Frequency Drive shall meet all requirements as outlined in the 1992 edition of IEEE std 519 for individual and total harmonic voltage and current distortion. The Point of Common Coupling (PCC) for all voltage and current harmonic calculations and measurements shall be the input terminals to the harmonic mitigation equipment..8 Total Harmonic Voltage Distortion (THVD) shall meet the requirements of Table 10.2 of IEEE std 519 by not exceeding 5% and by limiting the individual harmonic voltage distortion to less than 3%. These limits shall apply while operating on either utility supply or generator supply when applicable. The harmonic mitigation equipment vendor shall not be responsible for pre-existing voltage distortion caused by other harmonic sources..9 Total Demand Distortion (TDD) of the current at the input terminals of the harmonic mitigation equipment shall not exceed the limits as defined in Table 10.3 of IEEE std 519. For Isc/IL ratio < 20, TDD must be less than 5%. For all other Isc/IL ratios, the TDD must not exceed 8% even when Table 10.3 allows for more relaxed limits. For single-phase supply applications, the TDD must not exceed 12%..10 The full load efficiency of the harmonic mitigation equipment / VFD combination shall be greater than 96%. The harmonic mitigation equipment itself shall have efficiency no less than 99%. 2.2 Basic Requirements:.1 All wiring shall be copper..2 Insulation class: 220 C system. Temperature rise: 130 C.3 Anti-vibration pads shall be used between the reactor or transformer core and the enclosure..4 Ventilated, sprinkler proof NEMA-3R enclosure. 2.3 Other Requirements:.1 [OPTION] Submit for approval before shipment certified production test results with serial numbers for harmonic mitigation performance and energy efficiency under actual variable frequency drive loading. PART 3 - EXECUTION 3.1 Installation.1 The harmonic mitigation equipment shall be handled, stored and installed in accordance with the manufacturer's recommended installation practices as found in the installation, operation, and maintenance manual. Installation shall comply with all applicable codes. 3.2 Acceptance.1 [Option] Harmonic compliance shall be verified with onsite field measurements of both the voltage and current harmonic distortion at the input terminals of the harmonic mitigating equipment with and without the equipment operating. A recording type Fluke 41 or equivalent harmonics analyzer displaying individual and total harmonic currents and voltages must be utilized. Mirus International Inc. [ ] TO MIRUS MIRUS-S001-B7

13 LINEATOR TM Single Phase Universal Harmonic Filter (SUHF) (Patented) Standard 3-phase Variable Frequency Drives are often used as phase converters to supply 3-phase motors when only 1-phase power is available on remote locations such as farms, golf courses, oil and gas fields and residential areas for water and waste water systems. The Lineator-1Q3 TM has been designed to address this application by accepting 1-phase input and supplying a quasi 3-phase supply to the VFD. This will significantly lower both input harmonic current distortion (by up to 10x) and DC ripple current within the VFD. Reducing the ripple current may allow for less derating of the VFD. Treats all major harmonics generated by 3-phase Variable Frequency Drives when fed by 1-phase power (3rd, 5th, 7th, 9th, 11th, 13th ) 1 Q 1 Q3 3 The only passive harmonic filter for 3-phase VFD's operating on 1-phase supply TM Easily applied at the VFD input Helps meet IEEE 519 standard for both current and voltage distortion Input current demand distortion < 12% over entire operating range (10x reduction) Compatible with engine generators since capacitive reactance is < 20% of rated kva even under light loads Will not resonate with other power system components or attract line side harmonics Suppresses overvoltages caused by capacitor switching and other fast changing loads Built-in capacitor bank switching contactor to prevent VFD overvoltages at light loads

14 General Specifications: L LINEATORI N E EA T O R - 1Q3 TM HP / kw RATING Available for motor/drive system sizes up to 150HP / 110kW VOLTAGE Standard voltages up to 600V FREQUENCY 60Hz (50Hz available) HARMONICS TREATED 3 rd, 5 th, 7 th, 9 th,11 th, 13 th,... K-FACTOR SUITABILITY Up to 20 INPUT K-FACTOR Reduced to < 1.5 INPUT CURRENT DISTORTION < Full Load EFFICIENCY > 99% ELEVATION < _ 3300ft [1000m] above sea level AMBIENT TEMPERATURE < _ 104 Deg F [40 Deg C] VENTILATION Convection air cooled WINDING MATERIAL Copper ENCLOSURE NEMA 3R Grey (SU1, 2 & 3 suitable for Wall Mount) OPTIONS Nema 3R Enhanced * All LINEATOR 1Q3 units are shipped complete with a capacitor bank switching contactor and control system that automatically switches the filter capacitors off whenever the VFD is in the idle-no load ready-to-run mode. HP kw Input Amps (1ph/60Hz) % Fundamental % fund Amps Single Phase Universal Harmonic Filter Typical Application 10% 5% 0% Input Voltage Input Current Harmonic # Harmonic # 60 HP VFD Motor Horsepower HP 5 to 150 DIMENSIONS Case Style H in.[mm] SU [749] SU [864] SU [1016] [1143] MT [1308] 30 HP 480V Excess ripple current requires drive derating of 2x Vthd = 5.8% at input of VFD Ithd = 109% (VAC) W in.[mm] [260] [336] [470] [661] [813] 60 D Diode Bridge Rectifier T Thyristor Bridge Rectifier D in.[mm] [324] [406] [584] [635] [749] Application with Lineator-1Q3 TM Balanced 1-phase, 2-wire 1Q3 reduces ripple current which may allow for less derating when approved by VFD manufacturer ORDERING INFORMATION Model Line Frequency Load Enclosure Voltage Type Type SUHF VVV Hz L En O Input Current % Fundamental % fund Amps 10% 5% 0% Input Voltage Harm onic # Harmonic # 30 HP 1Q3 Unbalanced 3-wire E0P No Enclosure E1 Nema 3R Ventilated Mtg. Hole Center W [279] [457] [508] [546] [597] 50 HP VFD 30 HP 480V Balanced 3-phase, 3-wire Vthd = 2.0% at input of 1Q3 Ithd = 9.8% Motor Size Lineator Rating 240V (60Hz) 480V (60Hz) 600V (60Hz) Standard Enhanced Standard Enhanced Standard Enclosure Enclosure Enclosure Enclosure Enclosure Optional E Nema 3R Enhanced Mtg. Hole Center D [254] [330] [508] [483] [597] Enhanced Enclosure Output Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] 240VAC 480VAC 600VAC kva Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] [37] 84 [38] 74 [34] 77 [35] 71 [32] 74 [33] SU2 93 [42] SU2-E 96 [44] 84 [38] 87 [39] 80 [36] 83 [38] SU2 SU2-E SU2 SU2-E [50] 114 [52] 99 [45] 102 [46] 94 [42] 97 [44] [72] 165 [75] 119 [54] 122 [55] 112 [51] 115 [52] [86] 195 [88] 168 [76] 174 [79] 158 [72] 164 [75] SU3 213 [97] SU3-E 219 [99] 188 [85] 194 [88] 177 [80] 183 [83] [124] 279 [127] SU3 238 [108] SU3-E 244 [111] SU3 222 [101] SU3-E 228 [103] [151] 339 [154] 288 [131] 294 [133] 268 [121] 274 [124] [176] 397 [180] 318 [144] 324 [147] 295 [134] 301 [136] SU4 413 [187] SU4-E 421 [191] 358 [162] 366 [166] 333 [151] 341 [155] [209] 469 [213] SU4 398 [180] SU4-E 406 [184] SU4 369 [168] SU4-E 377 [171] [255] 593 [269] 458 [208] 466 [211] 424 [192] 432 [196] -E [299] 689 [312] 568 [258] 598 [271] 527 [239] 557 [252] -E -E MT4 847 [384] MT4-E 884 [401] 688 [312] 718 [326] 636 [288] 666 [302] 1. Approximate Values International Inc. MIRUS International Inc. 31 Sun Pac Blvd. Brampton, Ontario Canada L6S 5P6 Tel:(905) Fax:(905) Toll Free: TO MIRUS mirus@mirusinternational.com Website: R R SUHF-PS01-A6 Effective: February 2013 C Mirus International Inc. All specifications subject to change without notice.

15 MIRUS International Inc. TYPICAL SPECIFICATION LINEATOR-1Q3 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 Single Phase Universal Harmonic Filter (SUHF) PART 1 - GENERAL 1.1 Single phase to quasi 3-phase harmonic filter for 3-phase PWM AC Variable Frequency Drives being supplied with single phase voltage..1 The harmonic mitigation equipment and all of its components shall be manufactured and tested in accordance with the latest applicable standards of UL, CSA and NEMA..2 Demonstration of compatibility between the harmonic mitigation equipment and the VFD must be available upon request..3 Harmonic mitigation equipment shall be warranted to be free of defects in materials and workmanship for a period of 12 months from the date of start-up or 18 months from the date of shipment..4 Factory Performance Testing: Manufacturer must be capable of factory testing for harmonic mitigating performance and energy efficiency under actual variable frequency drive loads. A detailed description of the program and a sample test report must be provided at time of quotation..5 Subject to compliance with all of the contract documents and specifications, the acceptable product and manufacturer is: LINEATOR-1Q3 SUHF, by MIRUS International Inc. (905) , Toll Free: (888) PART 2 - PRODUCT 2.1 Key Requirements:.1 The harmonic mitigation equipment shall treat all of the characteristic low frequency harmonics generated by a 3- phase, diode bridge rectifier load when supplied with single phase voltage (3 rd, 5 th, 7 th, 9 th, 11 th, 13 th, etc.). Total Harmonic Current Distortion shall be reduced by more than 10x when compared to a VFD without harmonic treatment and shall be less than 12% when measured at the input terminals of the harmonic mitigation equipment under full load operation..2 The characteristic harmonics shall be suppressed without the need for individual tuning or the requirement to phase shift against other harmonic sources..3 Harmonic mitigation shall be by passive inductor/capacitor network. Active electronic components shall not be used..4 Power factor shall be.98 lagging to.95 leading in operating range from full to half load..5 To ensure compatibility with engine generators, the harmonic mitigation equipment must never introduce a capacitive reactive power (KVAR), which is greater than 20% of its kva rating..6 The harmonic mitigation equipment shall not resonate with system impedances or attract harmonic currents from other harmonic sources..7 The full load efficiency of the harmonic mitigation equipment / VFD combination shall be greater than 96%. The harmonic mitigation equipment itself shall have efficiency no less than 99%. 2.2 Basic Requirements:.1 All wiring shall be copper..2 Insulation class: 220 C system. Temperature rise: 130 C.3 Anti-vibration pads shall be used between the reactor or transformer core and the enclosure..4 Ventilated, sprinkler proof NEMA-3R enclosure. 2.3 Other Requirements:.1 [OPTION] Submit for approval before shipment certified production test results with serial numbers for harmonic mitigation performance and energy efficiency under actual variable frequency drive loading. PART 3 - EXECUTION 3.1 Installation.1 The harmonic mitigation equipment shall be handled, stored and installed in accordance with the manufacturer's recommended installation practices as found in the installation, operation, and maintenance manual. Installation shall comply with all applicable codes. 3.2 Acceptance.1 [OPTION] Harmonic compliance shall be verified with onsite field measurements of both the voltage and current harmonic distortion at the input terminals of the harmonic mitigating equipment with and without the equipment operating. A recording type Fluke 41 or equivalent harmonics analyzer displaying individual and total harmonic currents and voltages must be utilized. Mirus International Inc. [ ] TO MIRUS SUHF-TS001-A1

16 MIRUS International Inc. 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 THE LINEATOR-1Q3 TECHNICAL DATA Single Phase Universal Harmonic Filter (SUHF) [60Hz] GENERAL SPECIFICATIONS: SU1, SU2, SU3 ENCLOSURE DIM. - in. [mm] SU4, ENCLOSURE DIM. in. [mm] HP / kw RATING Available for motor/drive system sizes up to 150HP / 110kW VOLTAGE Standard voltages up to 600V FREQUENCY 60Hz (50Hz available) HARMONICS TREATED 3 th, 5 th, 7 th, 9 th, 11 th, 13 th, K-FACTOR SUITABILITY Up to 20 INPUT K-FACTOR Reduced to <1.5 INPUT CURRENT DISTORTION Full Load EFFICIENCY > Full Load ELEVATION 3300ft [1000m] above sea level AMBIENT TEMPERATURE 104 Deg F [40 Deg C] VENTILATION Convection air cooled WINDING MATERIAL Copper ENCLOSURE Type: NEMA-3R Paint: Polyester powder coated Colour: ANSI 61 Grey CASE A B C D E F G H SU [749] [336] [260] [324] [279] [254] [406] [279] SU [864] [514] [336] [406] [457] [330] [508] [457] SU [1016] [559] [470] [584] [508] [508], MT4 ENCLOSURE DIM. - inches [mm] CASE A B C D E F [1143] [661] [534] [635] [546] [483] MT [1308] [813] [648] [749] [597] [597] OPTIONS: Nema 3R Enhanced Motor Size Lineator Rating 240V (60Hz) 480V (60Hz) 600V (60Hz) Standard Enhanced Standard Enhanced Standard Enclosure Enclosure Enclosure Enclosure Enclosure HP kw Input Amps (1ph/60Hz) Enhanced Enclosure Output Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] Case Weight [1] 240VAC 480VAC600VAC kva Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] Style lbs [kg] [37] 84 [38] 74 [34] 77 [35] 71 [32] 74 [33] SU2 93 [42] SU2-E 96 [44] 84 [38] 87 [39] 80 [36] 83 [38] SU2 SU2-E SU2 SU2-E [50] 114 [52] 99 [45] 102 [46] 94 [42] 97 [44] [72] 165 [75] 119 [54] 122 [55] 112 [51] 115 [52] [86] 195 [88] 168 [76] 174 [79] 158 [72] 164 [75] SU3 213 [97] SU3-E 219 [99] 188 [85] 194 [88] 177 [80] 183 [83] [124] 279 [127] SU3 238 [108] SU3-E 244 [111] SU3 222 [101] SU3-E 228 [103] [151] 339 [154] 288 [131] 294 [133] 268 [121] 274 [124] [176] 397 [180] 318 [144] 324 [147] 295 [134] 301 [136] SU4 413 [187] SU4-E 421 [191] 358 [162] 366 [166] 333 [151] 341 [155] [209] 469 [213] SU4 398 [180] SU4-E 406 [184] SU4 369 [168] SU4-E 377 [171] [255] 593 [269] 458 [208] 466 [211] 424 [192] 432 [196] -E [299] 689 [312] 568 [258] -E 598 [271] 527 [239] 557 [252] -E MT4 847 [384] MT4-E 884 [401] 688 [312] 718 [326] 636 [288] 666 [302] Notes: 1. Approximate Values. 2. For additional information refer to: Typical Specifications, Internal Layout and Connection Diagrams. 3. For Thyristor Diode Bridge models, larger sizes and/or other enclosure types contact Mirus. 4. All LINEATOR 1Q3 units are shipped complete with a capacitor bank switching contactor and control system that automatically switches the filter capacitors off whenever the VFD is in the idle-no load ready-to-run mode. 5. Specifications are subject to change without notice. Mirus International Inc. [ ] TO MIRUS SUHF-S001-A6

LINEATOR. Advanced Universal Harmonic Filter

LINEATOR. Advanced Universal Harmonic Filter R International Inc. LINEATOR Patented Revolutionary New Reactor esign Advanced Universal Harmonic Filter Wide Spectrum Harmonic Filter for treatment of all harmonics generated by 3-phase diode or thyristor

More information

Lineator-HP High Performance model used where the highest power quality demands must be met

Lineator-HP High Performance model used where the highest power quality demands must be met LINATOR TM Advanced Universal Harmonic Filter The LINATOR Advanced Universal Harmonic Filter (AUHF) is a revolutionary advancement in the area of passive harmonic mitigation. No other device on the market

More information

How Harmonics have led to 6 Power Factor Misconceptions

How Harmonics have led to 6 Power Factor Misconceptions Harmonic and Energy Saving Solutions How Harmonics have led to 6 Power Factor Misconceptions Tony Hoevenaars, P.Eng. Power Factor Misconceptions 1. Low power factor is normally caused by electric motors

More information

Challenges of Parallel Operations

Challenges of Parallel Operations GENLINK TM issimilar Pitch Limiter Key Features Inserts >40% impedance in neutral current circulating path Reduces neutral circulating current by >75% Adds

More information

Electromagnetic Harmonic Filters Technical Guide

Electromagnetic Harmonic Filters Technical Guide Eliminator Series Electromagnetic Harmonic Filters Technical Guide Neutral Current Eliminator TM (NCE TM ) Parallel connected, 3-phase, 4-wire passive electromagnetic device that diverts 3rd and other

More information

GE Energy. Matrix Harmonic Filter Series D

GE Energy. Matrix Harmonic Filter Series D GE Energy Matrix Harmonic Filter Series D Matrix Harmonic Filter GE Matrix Harmonic Filters provide broadband reduction of harmonics. Matrix Harmonic Filters not only offer better performance over other

More information

MIRUS International Inc.

MIRUS International Inc. LINEATOR Universal Harmonic Filter for VFD s Questions and Answers This document has been written to provide answers to the more frequently asked questions we have received regarding the application of

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

WITH THEIR relatively weak generator-based power systems

WITH THEIR relatively weak generator-based power systems IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 49, NO. 3, MAY/JUNE 2013 1215 Preventing AC Drive Failures Due to Commutation Notches on a Drilling Rig A. H. Hoevenaars, Member, IEEE, Ian C. Evans, and

More information

Electromagnetic Harmonic Filters Technical Guide

Electromagnetic Harmonic Filters Technical Guide Eliminator Series Electromagnetic Harmonic Filters Technical Guide Neutral Eliminator TM (NCE TM ) Parallel connected, 3-phase, 4-wire passive electromagnetic device that diverts 3rd and other triplen

More information

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved

More information

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute

More information

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N Harmonic Basics 3 rd Harmonic Fundamental 5 t1h Harmonic 7 th Harmonic Harmonic

More information

Harmonics White Paper

Harmonics White Paper Harmonics White Paper New Breakthrough In PWM Drives Technology Reduces Input Line Harmonics Without the Use of Filtering Devices Harmonic Distortion Damages Equipment and Creates a Host of Other Problems

More information

THE FIRST STEP IN THE RESOLUTION OF VOLTAGE DISTORTION FOR SHARED GENERATORS AND MV UNDERSEA RING MAIN IN AN OFFSHORE OIL FIELD

THE FIRST STEP IN THE RESOLUTION OF VOLTAGE DISTORTION FOR SHARED GENERATORS AND MV UNDERSEA RING MAIN IN AN OFFSHORE OIL FIELD THE FIRST STEP IN THE RESOLUTION OF VOLTAGE DISTORTION FOR SHARED GENERATORS AND MV UNDERSEA RING MAIN IN AN OFFSHORE OIL FIELD Copyright Material IEEE Paper No. PCIC - Abstract Ian C. Evans Managing Partner

More information

7/15/2002 PP.AFD.08 1 of 28

7/15/2002 PP.AFD.08 1 of 28 Power Quality Considerations When Applying Adjustable Frequency Drives Explanations and Various Countermeasures 7/15/2002 PP.AFD.08 1 of 28 Power Quality Why the Renewed Interest in Power Quality? Copy

More information

PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer

PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer Transformerless drives help industry reduce the cost of motor control while using standard motors.

More information

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation Variable Frequency Drive Packages with Harmonic Mitigation Low Harmonic Drive Packages Engineered by Rockwell Automation What Do I Need to know About Harmonics? What are Harmonics? Harmonics are deviations

More information

The increase in the application

The increase in the application Harmonic mitigation for AC variable frequency pump drives Pump applications increasingly use AC variable speed drives. However, their operation introduces harmonic distortion of voltage supplies, which

More information

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE - 519 Solutions Harmonics Tutorial 1 Power Conversion Equipment can save energy and control motors, heaters,

More information

Amps Without HGA. Amps With HGA. Amps Without HSD Time (ms)

Amps Without HGA. Amps With HGA. Amps Without HSD Time (ms) Harmonic Solutions HarmonicGuard Active (HGA) Filter Save money and space: a single bus-applied HGA can correct harmonics for multiple loads Reduce current harmonic distortion to less than 5% allowing

More information

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive DRIVING POWER QUALITY ISO 9001:2008 Certification Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive Abstract December 18 th, 2012 Author: Todd

More information

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,

More information

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives .0 Volume 6 Solid-State Control CA0800007E March 05 www.eaton.com V6-T-47 .0 Adjustable Frequency Drives Overview What Are Harmonics? Take a perfect wave with a fundamental frequency of 60 Hz, which is

More information

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. Harmonic Mitigation for Variable Frequency Drives HWEA Conference February 15, 2011 Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. 1 OVERVIEW Linear vs. Non- Linear Load Definitions AC Drive Input Current Harmonics

More information

Harmonic Distortion and Variable Frequency Drives

Harmonic Distortion and Variable Frequency Drives Harmonic Distortion and Variable Frequency Drives Definitions Variable Frequency Drives (VFDs); sometimes referred to as variable speed drives. Harmonic Distortion is a measure of the amount of deviation

More information

Effective Harmonic Mitigation with Active Filters

Effective Harmonic Mitigation with Active Filters Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with

More information

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS Highly Efficient, System-Designed Solutions for Harmonic Distortion Introducing Danfoss Advanced Harmonic Solutions (AHS) Danfoss

More information

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement PQ01 Harmonic Solutions for VFD s Review of Power Control Harmonics, Power Factor, Distortion & Displacement Related Content at the Expo PQ02 Power Quality and Monitoring.. PQ03 Using Test Eqipment to

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

Economical Solutions to Meet Harmonic Distortion Limits[4]

Economical Solutions to Meet Harmonic Distortion Limits[4] Economical Solutions to Meet Harmonic Distortion Limits[4] Abstract: The widespread adoption of variable frequency drive technology is allowing electricity to be utilized more efficiently throughout most

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters Section [26 35 26][16280] Active Harmonic Filters (Low Voltage) Part 1 General 1.1 Summary A. Scope: Provide design and engineering, labor,

More information

Harmonic Filtering in Variable Speed Drives

Harmonic Filtering in Variable Speed Drives Harmonic Filtering in Variable Speed Drives Luca Dalessandro, Xiaoya Tan, Andrzej Pietkiewicz, Martin Wüthrich, Norbert Häberle Schaffner EMV AG, Nordstrasse 11, 4542 Luterbach, Switzerland luca.dalessandro@schaffner.com

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

Technical Paper. Harmonic Distortion in Data Centers

Technical Paper. Harmonic Distortion in Data Centers Technical Paper Harmonic in Data Centers Written By: Ian Wallace Summary Power quality and power reliability are critical to data center operation. As strides have been made to improve energy efficiency

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse ADJUSTABLE SPEED DRIVES HX7 Series 18-Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

Power Quality Solutions

Power Quality Solutions Power Quality Solutions What is Power Quality? For electrical systems to function in their intended manner without significant loss of performance or life, they require a supply of electricity that is

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

Reduce harmonics in HVAC&R inverters through C-Less technology

Reduce harmonics in HVAC&R inverters through C-Less technology Reduce harmonics in HVAC&R inverters through C-Less technology Karim Lamrabtine Global Product Manager VSD 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net What are Harmonics? Standards Compliance How

More information

Power Factor. Power Factor Correction.

Power Factor. Power Factor Correction. Power Factor. Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively

More information

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017 Harmonics and Their Impact on Power Quality Wayne Walcott Application Engineering Manager June, 2017 Presentation Overview A little about harmonics What are harmonics What are NOT harmonics What creates

More information

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive DRIVING POWER QUALITY ISO 9001:2008 Certification Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive Abstract November 13, 2012 Todd Shudarek,

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

VFDs and Harmonics in HVAC Applications

VFDs and Harmonics in HVAC Applications VFDs and Harmonics in HVAC Applications Larry Gardner Product Marketing Manager Yaskawa America, Inc. Jeff Grant Senior Sales Engineer LONG Building Technologies October 20, 2016 2016 Yaskawa America,

More information

PowerGard Series C 18-Pulse Enclosed Drive Controllers

PowerGard Series C 18-Pulse Enclosed Drive Controllers PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive and power quality solutions PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

Active Harmonic Filter

Active Harmonic Filter Reactive Power and Harmonic Compensation Active Harmonic Filter The new StacoSine Plus active harmonic filter is available in 100, 150, 200 and 300 amp assemblies. Modules can be paralleled for a maximum

More information

APPLICATION NOTE. Applying Type DD60 Capacitors in Harmonic Filter Applications. Total Power Factor PF = cosine ɸ

APPLICATION NOTE. Applying Type DD60 Capacitors in Harmonic Filter Applications. Total Power Factor PF = cosine ɸ APPLICATION NOTE SEPTEMBER 12, 2017 F-AN-001 FRAKO North America W67N222 Evergreen Bvd Suite 209 Cedarburg, WI 53012 Phone: 1-262-618-2403 Fax: 1-262-618-2303 www.frako.de Applying Type DD60 Capacitors

More information

Phoenix DX Clean Power (18 Pulse) AC Drive

Phoenix DX Clean Power (18 Pulse) AC Drive PHOENIX DX Phoenix DX Clean Power (18 Pulse) AC Drive Poor power quality can be costly. Nonlinear loads, including AC Drives, introduce undesirable harmonic currents into the power system that can damage

More information

How adjustable speed drives affect power distribution

How adjustable speed drives affect power distribution How adjustable speed drives affect power distribution Application Note Adjustable speed drives (ASDs) can be both a source and a victim of poor power quality. ASDs as victim loads Although ASDs are usually

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

APPLICATION GUIDE. Harmonics in HVAC applications

APPLICATION GUIDE. Harmonics in HVAC applications APPLICATION GUIDE Harmonics in HVAC applications Table of contents 4 Harmonics in general and why we should care 4 Introduction 4 Basics of harmonics 5 Causes of harmonic distortion 5 Problems caused

More information

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY Carrier Corporation Syracuse, New York October 2005 TABLE OF CONTENTS INTRODUCTION... 2 Common VFD Terms

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation TMdrive -XL Series Family Product Application Guide metals cranes mining testing oil & gas solar inverters power generation cement TMdrive-XL Series 8 MVA 15 MVA 20 MVA 30 MVA The TMdrive XL series family

More information

Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants

Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants Sherif M. Ismael Electrical Engineering Division, Engineering for the Petroleum and Process

More information

High Frequency SineWave Guardian TM Filter

High Frequency SineWave Guardian TM Filter High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion Harmonic Solutions Clean Power Drive Solution to Harmonic Distortion UTILITY GRID UTILITY SWITCH YARD IN THE FACILITY IEEE-519 POINT OF COMMON COUPLING POWER PLANT GENERATION TRANSMISSION MEDIUM VOLTAGE

More information

Harmonic Filters for Single Phase Equipment

Harmonic Filters for Single Phase Equipment POWER QUALITY Harmonic Filters for Single Phase Equipment Agriculture Call Centers Casino Slot Machines Computer Centers Distributed Generation Electronic Power Converter Oil & Gas On-Line UPS Power Electronics

More information

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products

More information

ULTRA-K Series 600K - he

ULTRA-K Series 600K - he 5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems

More information

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse ADJUSTABLE SPEED DRIVES W7 Series 18 Pulse Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating

More information

Drives 101 Lesson 5. Power Input Terminology for a VFD

Drives 101 Lesson 5. Power Input Terminology for a VFD Drives 101 Lesson 5 Power Input Terminology for a VFD This lesson covers the terminology associated with the incoming power to a Variable Frequency Drive (VFD) and the efforts to protect both the VFD and

More information

Reliable power onboard and offshore

Reliable power onboard and offshore Reliable power onboard and offshore AccuSine PCS+ Active Harmonic Filters For electrical network reliability and quality in Marine 2 What causes harmonics in Marine applications? Power electronics with

More information

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7 White Paper Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7 Dr. Jun-koo Kang, Yaskawa Electric America Doc#: WP.AFD.02 Copyright Yaskawa Electric America,

More information

NJWA - Harmonics and Drives Proper System Design

NJWA - Harmonics and Drives Proper System Design Session Goals Larry Stanley, Sr. Regional Business Development Engineer, Water Segment Matthew LaRue, ABB Drives Product Manager Philadelphia District, Baldor of Philadelphia NJWA - Harmonics and Drives

More information

VARIABLE FREQUENCY DRIVE

VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE Yatindra Lohomi 1, Nishank Nama 2, Umesh Kumar 3, Nosheen aara 4, Uday Raj 5 (Assistant Professor in Department of Electrical Engineering GIET Kota2) (Department of Electrical

More information

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS High voltage shunt capacitor banks Alstom Grid high voltage shunt capacitor bank offering is divided in: By bank construction HV open rack capacitor banks HV enclosed capacitor banks By bank design HV

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web:  - ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors. and Drives Control R Interface OBICON Perfect Harmony Short overview 14.03.2007 1 System overview Product features Truly Scaleable Technology 300 kw to 30 MW (Single Channel) Large Number of Framesizes

More information

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and

More information

Power Factor & Harmonics

Power Factor & Harmonics Power Factor & Harmonics Andy Angrick 2014 Harmonic Distortion Harmonic problems are becoming more apparent because more equipment that produce harmonics are being applied to power systems Grounding Harmonics

More information

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES FS1 ADJUSTABLE SPEED DRIVES FS1 Now Available With LonWorks BACnet & MetasysN2 FS1 Model FLA & Dimensions (in.)/ Weight (lbs.) VOLTAGE HP MODEL NUMBER FLA FRAME Dimensions (in.) SHIPPING H W D WEIGHT (lbs.)

More information

Isolation Transformer Series

Isolation Transformer Series Isolation Transformer Series Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment

More information

Harmonic Mitigating Transformer - Technical Guide

Harmonic Mitigating Transformer - Technical Guide Harmonic Mitigating - Technical Guide HARMONY Series s HARMONY-1 www.mirusinternational.com Benefits: Prevent voltage flat-topping while reducing energy costs. Reduce voltage distortion caused by harmonic

More information

Meduim Voltage Drives

Meduim Voltage Drives YANTRA HARVEST Meduim Voltage Drives YANTRA HARVEST ENERGY PVT. LTD. Office No. 101, 102, 103, Plot No. 84, Survey No. 40, Ambedkar Road, Sangamwadi, Near RTO Office, Pune - 411001 (India) Tel / Fax :

More information

Power-Sure 700. Technical Data TD158001EN. Contents

Power-Sure 700. Technical Data TD158001EN. Contents Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...

More information

CHAPTER 4 HARMONICS AND POWER FACTOR

CHAPTER 4 HARMONICS AND POWER FACTOR 4.1 Harmonics CHAPTER 4 HARMONICS AND POWER FACTOR In this research a comparative study of practical aspects of mixed use of diode and Thyristor converter technologies in Aluminium Smelters has been carried

More information

Open-Delta Systems Affect Variable Frequency Drives

Open-Delta Systems Affect Variable Frequency Drives Open-Delta Systems Affect Variable Frequency Drives To avoid premature drive failure, proper precautions must be taken when installing VFDs on open-delta supplies. Written by: Dan Peters, Yaskawa America,

More information

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD) Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics

More information

Medium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON

Medium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON Medium Voltage Drives in Industrial Applications By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON Outline Introduction Medium Voltage Drive Topologies A Brief Comparison Power Semiconductors

More information

Understanding Input Harmonics and Techniques to Mitigate Them

Understanding Input Harmonics and Techniques to Mitigate Them Understanding Input Harmonics and Techniques to Mitigate Them Mahesh M. Swamy Yaskawa Electric America YASKAWA Page. 1 Organization Introduction Why FDs Generate Harmonics? Harmonic Limit Calculations

More information

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005 ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005 Two Types of Electrical Loads Linear Non-Linear INCANDESCENT LIGHTING COMPUTERS INDUCTION MOTORS VARIABLE FREQUENCY DRIVES FLUORESCENT

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified 8/23/17 Updated sections on System Design and Performance Requirements; Submittals; Equipment; Accessories or Special Features; Quality

More information

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers Power Quality 13 Answering Today s Power Challenges Jefferson Electric is continually updating its product line to remain on the forefront of transformer technology. Electrical harmonics have become a

More information

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Dry Type Transformers Full Line Catalog. jeffersonelectric.com Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production

More information

Thyristorised Automatic Power Factor

Thyristorised Automatic Power Factor Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

Figure 1 Typical Inverter Block Diagram

Figure 1 Typical Inverter Block Diagram AC Drives and Soft Starter Application Guide Walter J Lukitsch PE, Gary Woltersdorf Jeff Theisen, John Streicher Allen-Bradley Company Milwaukee, WI Abstract: There are usually several choices for starting

More information

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation UPEC21 31st Aug - 3rd Sept 21 Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation H. M. Zubi IET and IEEE member hz224@bath.ac.uk R. W. Dunn IEEE member E-mail r.w.dunn@bath.ac.uk

More information

Reducing Total Harmonic Distortion with Variable Frequency Drives

Reducing Total Harmonic Distortion with Variable Frequency Drives Reducing Total Harmonic Distortion with Variable Frequency Drives Low Harmonic Technology in Optidrive Eco Overview Overview Both AC line chokes and DC link chokes have historically been used with Variable

More information

Principles for Controlling Harmonics

Principles for Controlling Harmonics Principles for Controlling Harmonics Harmonic distortion is present to some degree on all power systems. Fundamentally, one needs to control harmonics only when they become a problem. There are three common

More information

Power IT LV Active Filters PQFA - PQFL - PQFT

Power IT LV Active Filters PQFA - PQFL - PQFT Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS PM734D - Winding 312 Technical Data Sheet PM734D SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT PM734F - Winding 312 Technical Data Sheet PM734F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information