1 Harmonic Solutions HarmonicGuard Active (HGA) Filter Save money and space: a single bus-applied HGA can correct harmonics for multiple loads Reduce current harmonic distortion to less than 5% allowing you to meet IEEE-519 specifi cations Easily monitor performance & remotely control the HGA with one of our communications options Patented Master - Master operation allows multiple fi lters to run in a more robust closed-loop mode Amps Without HGA Injection Current Amps With HGA HarmonicGuard Passive (HGP) Filter 3 2 Meets IEEE-519 requirements by limiting current harmonic distortion to less than 5% with background voltage distortion as high as 5% Internal fusing prevents capacitor damage 1kA SCCR simplifi es system acceptance Available with a wide range of options to suit any application Generator compatible Amps Without HGP Amps With HGP HarmonicShield (HSD) Filter 4 2 The HarmonicShield is TCI s newest addition to our passive harmonic fi lter line. 5% ithd Performance over a wide load range UL 58 Listed Available in UL Type 1 and Type 3R package 48V and 6V, up to 6 HP Optional contactor Available with or without lugs Amps Without HSD Amps With HSD KDR/KLR Line Reactor Extend your drive uptime by reducing the likelihood of the drive tripping Protect other equipment on the same bus from operational issues caused by voltage distortion Reduce overheating issues due to harmonic currents Visit Us At:

2 Power Factor Correction PF Guard TM Capacitor Bank Automatic Cap Bank prevents leading power factor and reduces apparant power drawn from the utility Returns power factor to near unity Includes a detuning reactor to mitigate resonance issues Motor Protection Solutions MotorShield TM Sinewave Output Filter (for cable leads up to approximately 15, ft.) Protect your motor and cable runs by reduction of vibration and heat to improve system performance Protects older and non inverter duty motors from the harmful effects of voltage spikes caused by VFDs Reduce audible motor noise Ideal for protecting lead insulation in downhole pumping applications Volts Without MotorShield Volts With MotorShield V1k dv/dt Output Filter (for cable leads up to approximately 1,5 ft.) Extend the life of your motor and cable by reduction of harmful voltage spikes due to dv/dt Protect cable runs and reduce motor heating, noise and vibration Prevent motor failure with protection against motor insulation breakdown Volts feet Without V1k Volts High Frequency Noise Solutions KRF EMC Filter With V1k 5 feet Filter EMI/RFI noise caused by power switching devices Prevent interference between automated lighting circuits, security cameras, and other critical electronics on your system TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #27865 Version 1.6 Copyright 216

3 Power Factor Correction The Power of PF Guard Avoid penalty fees and high utility bills with TCI s PF Guard. By providing reactive power to your system the PF Guard will improve your facility s power factor to near unity. This reduces the amount of costly apparent power the utility must provide. The PF Guard will reduce the demand on your electrical equipment, resulting in improved electrical system capacity and a more effective power supply. Powerful Features The PF Guard offers an automatic switching design, providing an optimized solution for your application. A detuned, anti-resonance reactor is built into the unit for an extra layer of protection from harmonics and to prevent equipment failure, reduce costs and increase the life of the system. What is Power Factor? All inductive loads require two types of power to function properly: Active power (kw) performs real work in loads such as motors Reactive power (kvar) is consumed by inductive loads such as AC motors and performs no productive work Power Factor is the ratio between the active power and the total power consumed (apparent power or kva) and is the standard measure of how effectively electrical power is being used by a system. Why Improve Power Factor? When the power factor is below 1. or unity, the electrical capacity of the system decreases, forcing the utility to supply more apparent power than necessary. Utilities can pass on the resulting costs to the industrial users as power factor penalties and high utility bills. Issues caused by low power factor may include: Poor system performance High energy costs Electric surcharges Harmful environmental impacts

4 Power Factor Correction Technical Characteristics Voltage Rating 48 VAC Phase 3-Phase Operating Frequency 6 Hz Fuse Interrupt Rating 2kA SCCR Rating 1kA: Terminal block, disconnect switch or fuse block option 5kA: Circuit breaker only, 65kA: With customer supplied fusing KVAR Rating(s) 15, 2, 25, 3, 4, 5, 6 Voltage Unbalance 1% maximum Continuous Overvoltage 11% Capacitor Tolerance ±5% Expected Life Over 13, operating hours Maximum Harmonic Voltage 5% Discharge Time Less than 1 minute Environmental Conditions Operating Temperature Enclosed: -1 C (14 F) to 4 C (14 F) Storage Temperature -3 C (-22 F) to 6 C (14 F) Relative Humidity 95% non-condensing Operating Altitude Up to 1,m without derating Cooling Method Forced Air Convection Reference Technical Standards Protection (Enclosure) UL Type 1 Agency Approvals UL 58A Part Numbering System Typical Applications Large Industrial Heavy Manufacturing Wood Processing Steel / Paper Mills Tire / Rubber Refi neries Mining TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #29745 Version 1.3 Copyright 215

5 Harmonics & Power Quality Poor power quality can be a result of variable frequency drives or other types of non-linear loads using a power conversion process that causes current and voltage distortion. This resulting distortion is known as harmonics. Issues caused by harmonics may include: Transformer and distribution equipment overheating Random breaker tripping Sensitive equipment failure Poor power factor HarmonicGuard Active Filter The HarmonicGuard Active (HGA) filter monitors the load current and reacts to changes almost instantaneously. A counter current is injected by the unit to cancel out harmonics and synchronize the current and voltage waveforms. True power factor will be returned to near unity if power factor correction is enabled on the filter. The HGA meets even the most stringent IEEE requirements with its advanced technology. A large, built-in, 65k color touchscreen HMI display with LED backlight is included, along with the communication options of Modbus RTU over RS485, Modbus TCP/IP, EtherNet/IP, DeviceNet and HGA-HMI. HGA Filters vs. Other Harmonic Solutions In comparison to 18-pulse drives, the HarmonicGuard Active filter is superior in many aspects and features including: The HGA is a bus-applied solution eliminating the need for harmonic correction at each drive which results in significant savings Can be installed in an MCC section Offers up to a 65% reduced footprint when coupled with a standard 6-pulse drive The HGA is a shunt-applied device: a failure will not shut down your processes Can be less expensive than multi-pulse and AFE (active front-end) variable frequency drives Optional add-ons: (contact factory for more details) Ready to assemble wall mount or floor stand Portable HMI unit (HGA-HMI) for 3R units Remote mountable HMI unit for open chassis and 3R units Advantages of the HarmonicGuard Active Filter The HGA s patented master-master operation provides unparalleled accuracy not found in other active filters Up to six HGA filters can be connected in parallel to increase correction capability Automatic harmonic cancellation Remaining capacity, after harmonic target is achieved, can be applied towards power factor correction Bus-Applied Configuration for MCC or Switchboard The HGA can be directly connected to the power bus in standard MCC and Switchboard configurations. Large, 65K Color HMI Typical Applications Wastewater Treatment Plants Mining Material Handling Oil & Gas HVAC Systems Chemical Processing Data Centers Renewable Energy Pulp & Paper

6 Technical Specifications Compensation Capacity (Parallel for High Capacity) Technical Characteristics Power Factor Correction Response Time Harmonic Cancellation Spectrum 48 V: 5A, 1A, 15A, 2A, 25A, 3A, 4A, 5A; 3-phase, 6 Hz 6 V: 39A, 78A, 11A, 15A, 185A, 22A, 37A; 3-phase; 6 Hz Up to.98 lagging Less than 8 ms to step load changes To the 5th harmonic - auto-selecting RMS Current Attenuation Less than 1:1 Parallel Configuration Up to six active filters can be connected in parallel* Display High quality 6 65k color touchscreen with LED backlight Communications Modbus RTU over RS485, Modbus TCP/IP, EtherNet/IP, DeviceNet, HGA-HMI Environmental Conditions Open Chassis: C (32 F) to 4 C (14 F) Derating above 4 C UL Type 1: C (32 F) to 4 C (14 F) Derating above 4 C Operating Temperature UL Type 12: C (32 F) to 4 C (14 F) Derating above 4 C UL Type 3R: -2 C (-4 F) to 4 C (14 F) Derating above 4 C Relative Humidity 95%, non-condensing Operating Altitude 1, m (3,3 ft), up to 3, m (9,9 ft) with derating Storage Temperature Open Chassis, UL Type 1 & UL Type 12: -2 C (-4 F) to 6 C (14 F) UL Type 3R: -4 C (-4 F) to 6 C (14 F) Reference Technical Standards Agency Approvals UL & cul Listed Protection (Enclosure) Open Chassis, UL Type 1, UL Type 12, UL Type 3R Over Current Protection Molded Case Circuit Breaker HMI Languages English, French, Spanish Surge Protection ANSI C62.42 Warranty One year of useful service, or 18 months from shipment *Consult factory for larger systems. Non-linear Load Waveform Resulting Line Current Waveform TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #28722 Version 1.7 Copyright 216

7 Harmonics & Power Quality TCI s HarmonicGuard Passive gives you options. Our HGP 5% harmonic filter is a performance product with the versatility to tackle tough application challenges. This field-proven passive fi lter has factory options available to meet your specifi c requirements, such as: Contactor - Can be used to disconnect capacitors to prevent leading power factor. Fuse Monitor - The fuse monitor will detect a fuse failure. Heater - Protects internal fi lter electronics from corrosion and condensation. Vibration Pads - Reduces audible noise. Floor Stand - 12 steel feet for Type 3R enclosures 125hp and below. Units 15 hp and above include provisions for fl oor mounting. Custom designs are available upon request. HarmonicGuard Passive Filter Limits current harmonic distortion to less than 5% over a wide load range Industry leading performance under high background voltage distortion True 1kA SCCR IEEE compliant Generator compatible Increases drive uptime Eliminates nuisance tripping ithd% vs. % Load % ithd % Load HGP Filters vs. Other Harmonic Solutions Today s marketplace has provided numerous products intended to address harmonics and power quality issues in industrial applications. TCI is focused on developing solutions that offer the lowest total cost of ownership for the end user. Compared to 18-pulse drives, the HGP: Is a more efficient and reliable solution at reduced loads Has a better ithd at reduced loads Saves money by reducing operation costs and energy loss Has a smaller footprint Compared to Active Front End, the HGP: Does not require input (LCL and EMI/RFI) filters as AFE does. Is a more cost effective solution. Produces no ground leakage current. Application The HGP filter is a drive applied 5% passive harmonic filter. High quality components and a robust design allow this passive filter to deliver best in class performance under the harshest conditions and in the most challenging applications. Typical Applications Oil & Gas Steel Industry Water/Wastewater HVAC Systems Machining Airports Commercial Buildings Hospitals Irrigation Fields, Farms Extruders Pulp & Paper

8 Technical Specifications Voltage / Frequency Rating 28, 24, 48 & 6 VAC- 6 Hz 4 VAC- 5 Hz Phase 3Ø Motor drive input power rating range 28, 24 VAC: 5-1 Hp 4 VAC: 4-1 KW 48, 6 VAC: Hp SCCR (Short Circuit Current Rating) 1 ka Immunity from Voltage Distortion Less than 5% ithd at full load with vthd as high as 5%* THID Less than 5% at full load Efficiency Greater than 99% Overload Capability 2% of current rating for 3 minutes Environmental Conditions Operating Temperature Open: 5 C (122 F), Enclosed: 4 C (14 F) Storage Temperature 6 C (14 F) Elevation Up to 1, m without derating. Consult factory for higher elevations. Humidity 95% non-condensing Protection Category Open Chassis, UL Type 1, UL Type 3R and Type 12 enclosure Cooling Method Natural or Forced Air Convection Reference Technical Standards Agency Approvals culus Part Numbering System H G P 1 5 L X 1 S Series: Rating (HP - 6Hz) ( kw - 5 Hz ): Voltage Rating: A - 48 V B - 24 V C - 6 V D - 28 V L - 4 V Frequency: W - 6 Hz (HP Rated) X - 5 Hz (kw Rated) Enclosure: - Open 3 - Type 3R 1 - Type Type 12 Option: S - Standard C - Contactor F - Contactor and Fuse Monitor G - Standard & Fuse Monitor Option: - Standard Option: - Standard F - Floor Stand (for 15 HP and below Type 3R & 2 HP and below Type 1) Option: - Typical Voltage Distortion 1 - High Voltage Distortion Option: - Standard H - Heater (only available on Type 3R Enclosures) P - Oilfield Version V - Vibration Pads P One-Line Diagram (System Bus/ Panel/ Source Transformer) LINE Current Distortion (ithd) vs. Background Voltage Distortion (vthd) % ithd LINE REACTOR FUSE % vthd (VFD) LOAD CONTACTOR(S) (Optional) TUNING REACTOR CAP(S). *When configured for High Background Voltage Distortion. See IOM for guidelines for distortion above 5%. TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #28559 Version 1.8

9 Harmonics & Power Quality TCI s HarmonicShield passive harmonic filter offers the best-in-class performance that you expect from TCI at a price that you don t. TCI s new HarmonicShield is a 5% passive harmonic fi lter designed for a wide variety of standard duty indoor and outdoor environments, wherever a VFD is used. Harmonics Power system harmonics are not new. However industrial equipment generate more harmonics than ever while simultaneously sensitive electronic equipment is becoming increasingly susceptible. Couple this with the transformer heating and nuisance breaker trips caused by harmonics as well as the utilities IEEE-519 mandate and managing harmonics is no longer optional. And while the problem is well known, the solution can at times be confusing. Multi-pulse drives, harmonic mitigating transformers, active front end drives, standard VFD with harmonic mitigating equipment; which one is right for you? HarmonicShield TCI s new HarmonicShield can make the decision easy. The HarmonicShield offers industry leading 5% ithd performance even at light loads and under the harshest of conditions. The optional contactor allows the tuning circuit to be disconnected at light loads to avoid leading power factor problems. Natural convection cooling means no moving parts. A lug kit option accommodates oversized cabling if needed. All this is backed up by TCI s 3 year warranty, which means you will have many years of hassle free operation. General Application and Maintenance Free The HarmonicShield (HSD) filter is built using the highest quality components and is suitable for general power quality applications and normal environmental conditions. The HSD filter is designed with simplicity in mind. This convection cooled, maintenance-free fi lter requires no adjustments once installed. Typical Applications Oil & Gas Equipment Metal Processing Equipment Water/Wastewater Pump Systems HVAC Compressors and Blowers Irrigation Pumps Extruders Pulp & Paper Mills ithd 12% 1% 8% 6% 4% 2% The Economics of Harmonics If you re like most, spending the least possible amount of your budget on harmonic mitigation is a goal. A 6-pulse drive with TCI s new HarmonicShield passive harmonic filter is the most cost effective method of meeting IEEE-519: 214 s tightest standards. When compared to an 18-pulse drive solution the HarmonicShield and 6-pulse drive combination can save you up to 46%. And when compared to an active front end drive that number shoots up to 59%. The HarmonicShield offers TCI s industry best performance in an economical package. Price Ratio ithd Price Ratio % 6-Pulse Drive 6-Pulse Drive + Line Reactor 6-Pulse Drive + HarmonicShield 18-Pulse Drive HSD vs. Other Harmonics Solutions Active Front End Drive.

10 Technical Specifications Voltage / Frequency Rating 48 & 6 VAC- 6 Hz Phase 3Ø Immunity from Voltage Distortion Less than 5% ithd at full load with vthd as high as 5% ithd Less than 5% at full load Efficiency Greater than 99% Overload Capability 2% of current rating for 3 minutes Environmental Conditions Operating Temperature 4 C (14 F) Storage Temperature 6 C (14 F) Elevation Up to 1, m without derating. Consult factory for higher elevations. Humidity 95% non-condensing Protection Category UL Type 1 and UL Type 3R Cooling Method Natural Convection Reference Technical Standards Agency Approvals UL & cul Listed (up to 6 Hp) NOTE: The HSD is classifi ed as an Auxiliary Device, not an industrial control panel. Under UL and NFPA NEC guidelines an SCCR rating or marking is not required. Part Numbering One-Line Diagram H S D 1 5 A W 3 Series: Horse Power: Voltage Rating: A - 48 V C - 6 V Frequency: W - 6 Hz Enclosure: 1 - UL Type UL Type 3R Option: - Standard, no contactor 1 - With contactor Option: - Standard, no lugs 1 - Lugs Option: - Standard Option: - Standard Line Line Reactor Load Contactor (opt.) Tuning Reactor Capacitor(s) Application Matrix TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #3253 Version 1.2 Copyright 216

11 HARMONIC FILTER DRIVE-APPLIED HARMONICGUARD HG7 Limits harmonic distortion and improves power factor Meets IEEE Protects drives and other sensitive equipment Improves energy efficiency Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filters

12 HARMONIC FILTER DRIVE-APPLIED HARMONICGUARD HG7 Harmonic Current Distortion Without HG7 Amps Harmonic Current Distortion with HG7 applied Amps Typical Problems, Superior Solutions with HG Filters Power quality has degraded over time due to the increased use of non-linear loads. The IEEE-519 standard for harmonic distortion was developed to address this problem. An increasing number of utilities are now mandating that this standard be followed. Harmonics and Power Quality Variable frequency drives are beneficial for a wide range of applications, however VFDs contain a power conversion process that creates current and voltage distortion which can cause system-wide problems. If non-linear loads represent a significant portion of the entire installed load, this distortion begins to cause problems throughout the electrical system: Transformer and distribution equipment overheating Random breaker tripping Sensitive equipment may fail completely Poor power factor Reduced system efficiency The HG7 Passive Harmonic Filter The HG7 not only limits current distortion to less than 7% (5-6% typical), it also: Eliminates nuisance tripping Increases drive uptime dramatically Improves power factor Improves system efficiency & reliability Extends equipment life Meeting IEEE-519 Recommendations on Harmonics The HG7 passive filter provides a cost effective solution allowing the user to meet IEEE-519 requirements. Using our harmonic analysis software, TCI can help customers meet IEEE-519. Typical applications include: Wastewater treatment plants Commercial buildings Hospitals Airports HG7 Filters v. Other Harmonic Solutions The HG7 passive filter is built using the highest quality components. HG7 filters include capacitors designed to withstand harsh harmonic currents. The UL58A configuration includes built-in safety features like fusing and easy access inside the enclosure. Processes will not shut down if the filter goes off-line. When compared to multi-pulse solutions, HG7 filters: Save money Save space Reduce energy losses

13 Configure the HG7 to meet your performance and monitoring needs: ST - Part Numbering System High Quality Harmonic Filter HG 15 A W 3 STC Series HP Voltage Rating A = 48V, B = 24V, C = 6V, L = V Frequency X = 5 Hz, W = 6 Hz Enclosure = Open, 1 = UL Type 1, 3 = UL Type 3R Package Option ST = Base Option Package STC = Contactor & CPT Option Package STCH = Contactor & CPT Option Package with Heater XM = Power Monitor Package KP = Component Package Package Options STC - High Quality Harmonic Filter with contactor and control power transformer which allows users to remove the capacitors from circuit, eliminating the possibility of leading power factor Product Specifications 3-Phase Ratings: 48V/6Hz: HP 6V/6Hz: 15-9 HP 24V/6Hz: HP 4V/5Hz: 4-71 kw Harmonic Reduction: < 7% (Typically better TDD) at full load Efficiency (typical): Below 1 HP 98% 1-25 HP 98.8% Above 25 HP > 99% Capacitors: Components designed for harmonicrich environments Protection: All units have internal fusing protection for the capacitors and trap reactor Operating Temperature: Open: 5 C (122 F) Enclosed: 4 C (14 F) Maximum Altitude: 1, m (Derating necessary above 1, m) XM - Similar to STC version with the addition of a power monitor display to view filter performance One-Line Diagram Fundamental Frequency: 6 Hz (5Hz for 4V) Agency Approvals: cul, UL Enclosures: Open, UL Type 1, UL Type 3R HG7 HarmonicGuard Filters are warranted for three years from the date of original shipment (System Bus/ Panel/ Source Transformer) LINE LINE REACTOR FUSE (VFD) LOAD TUNING REACTOR CONTACTOR(S) (Optional) CAP(S). Performance Guarantee When properly applied and sized for the application, HG7 will typically provide 5-6% current distortion. TCI further guarantees that the HG7 will lower ITDD (as calculated using IEEE-519 guidelines) to no more than 8% at the filter input terminals. If a properly selected, installed, and loaded HG7 filter fails to meet the guaranteed performance levels, TCI will provide the necessary components or replacement filter at no additional charge. TCI does not take responsibility for additional installation or removal costs, to include, but not limited to, replacement of third party equipment. Please see TCI web site for minimum system requirements.

14 HG7 Typical Applications Oil and Gas Pumps Irrigation Fields, Farms Water, Wastewater HVAC Steel Industry Pulp/Paper Machining Extruders Additional Power Quality Solutions: HarmonicGuard Active (HGA) Filter Helps meet IEEE-519 Reduces current harmonic distortion to less than 5% at full load Actively monitors system current, improves power factor to near unity Built-in touchscreen display & Modbus RTU Copyright 215 Part Number: 2522 Version 1.5 KDR Line Reactor Prevents nuisance tripping Protects the source by lowering current distortion created by the drive MotorGuard TM Sinewave Output Filter Protects the motor by converting the PWM waveform into a near sinusoidal wave Prevents voltage overshoots that cause early degradation of insulation systems in motors, transformers, and cables Extends motor life by reducing operating temperature V1k Motor Protection Output Filter Protects the motor and cable from voltage spikes due to high dv/dt and excessive cable capacitance Helps stop motor insulation breakdown Protects cable runs (up to 3, feet) and reduces motor heating, noise and vibration KRF EMI/RFI Filter Filter EMI/RFI noise caused by power switching devices Meet FCC regulation 15, subpart J Prevents interference with automated lighting circuits, security cameras, and other critical electronics TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Please contact us about specific products and services. Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filters

15 Harmonics & Power Quality KDR Line Reactor Variable frequency drives (VFD) are beneficial to a wide range of applications, but contain a power conversion process that creates current and voltage distortion, known as harmonics. Issues caused by harmonics may include: Transformer and distribution equipment overheating Random breaker tripping Sensitive equipment failure Poor power factor KDR Line Reactor The KDR Line Reactor offers impedance against the flow of harmonics and other high frequencies that can cause tripping and equipment failure. Drives and other sensitive devices are protected by the KDR from electrical distortion on the line including harmonics. Harmonic Current Distortion Without KDR 3 2 Advantages of the KDR Line Reactor Extend the life of the motor on the output of the VFD Protect other equipment on the line from operational issues caused by voltage distortion Dramatically increase drive uptime by reducing the likelihood of the drive tripping Improve power factor Reduce motor heating and audible noise Increase system productivity Meet IEEE Typical Applications Pulp & Paper Machining Wastewater Treatment Plants Oil & Gas HVAC Systems Irrigation Fields, Farms Extruders Steel Industry Warranty Every TCI line reactor is manufactured in Wisconsin with high quality materials and is backed by a lifetime warranty.* Amps Transient Voltage Without KDR Harmonic Current Distortion With KDR Bus Volts Amps Transient Voltage With KDR Bus Volts Manufactured in Germantown, Wisconsin

16 Technical Specifications Environmental Conditions Operating Temperature Operating Altitude Reference Technical Standards Agency Approvals Fundamental Frequency Impedance Protetion System Voltage Short Term Overload Rating Inductance Characteristics Input and Output Protection (enclosure) DIN Rail version available Open: 5 C (122 F) Enclosed: 4 C (14 F) 2, m (6, ft) Derating necessary above 2, m cul, UL; UL Recognized, CE Marked 5/6 Hz Low Z and High Z 28/24 VAC, 48 VAC, 575/6 VAC, 69 VAC Tolerate 2% rated I for a minimum of 3 minutes Minimum 95% L at 11% Load Minimum 8% L at 15% Load Available for either the line or load side of a VFD Open, UL Type 1, UL Type 3R See website for details Impedance Options KDR Line Reactors have been designed to provide the best protection for both your drive and your application. KDR Optimized Drive Reactors are available in two ratings versions, Low Z (low impedance) and High Z (high impedance). Input impedance can significantly improve drive performance. Select impedance based on the guidelines below: Use KDR Low Z Units For: Any application where either a 1.5% or 3% reactor would be applied. Reduction of nuisance tripping caused by: Transient voltages caused by capacitor switching Line notching DC bus overvoltage tripping Inverter overcurrent and overvoltage Additional benefits include: Lowering injected percentage of harmonic current Improving true power factor Reducing cross-talk between drives Adding impedance to drives with DC link chokes/ reactors when more impedance is desired due to a relatively stiff source Performance Guarantee Properly sized for the application, a KDR reactor is guaranteed to eliminate any AC drive overvoltage tripping problems. If a KDR reactor is installed and the tripping problem remains, TCI will take back the reactor and pay shipping both ways. (Offer valid for 6 days from date of shipment.) Use KDR High Z Units For: Any application where a 5% reactor would be applied. KDR High Z offers the same superior benefits as Low Z plus additional benefits which include: Helping prevent drive component damage Providing maximum harmonic mitigation without adding capacitance Part Numbering System KDR Series UL Listed (Blank if UL Recognized) Design Frame Sequence Code Impedance Rating L = Low Impedance H = High Impedance P = Output Reactor Enclosure E1 = UL Type 1 E3R = UL Type 3R KDR UL A 55 H E3R *For the life of the drive TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #2332 Version 1.5 Copyright 215

17 HIGH PERFORMANCE SINEWAVE OUTPUT FILTER MotorGuardTM Eliminate harmful dv/dt to result in sinewave output Allows Nema MG1 Part 3 motors to be used where Part 31 motors would otherwise be required Greatly extend motor and cable life by reduction of motor noise, vibration, and heat Specific applications can reach 15, feet Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filters

18 HIGH PERFORMANCE SINEWAVE OUTPUT FILTER MotorGuard Typical Problems, Superior Solutions with MotorGuard As Pulse Width Modulated (PWM) Drives are incorporated into various applications and processes, the increased energy savings and decreased maintenance on Drives can be offset by increases in Motor failures. Voltage Without MotorGuard The MotorGuard product family has been designed as an engineered solution for motor failures due to the reflected wave phenomenon. Reflective Wave Phenomenon Voltage wave reflection is a function of the voltage rise time (dv/dt) and the length of the motor cables. Volts The impedance on either end of the cable run does not match, causing voltage pulses to be reflected back in the direction from which it arrived. As these reflected waves encounter other waves, their values add, causing higher peak voltage. As wire length or carrier frequency increases, the overshoot peak voltage also increases. Voltage With MotorGuard Volts Peak Voltages on a 46V system can reach 12 to 16V, causing rapid breakdown of motor insulation, leading to motor failure. On 575V systems, the peak voltages can easily reach 21V. If this is left uncontrolled, insulation failure may occur. Eliminate Reflective Wave The MotorGuard filter converts the PWM wave form to a near sinusoidal wave form by eliminating the carrier frequency, allowing sensitive applications to take advantage of the efficiencies and savings that PWM output power supplies and drives offer. MotorGuard filters: Eliminate Torque Ripple Eliminate Voltage Wave Reflection Can reach 15, feet for specific applications Reduce Motor Noise, Vibration, and Heat Increase Motor Life May be used with virtually all AC induction motors, lead lengths and lead types Can be used with a wide range of carrier frequencies from 2 khz to 12 khz and beyond.

19 58A Industrial Enclosure UL Listed Part Numbering System Series Current Rating Voltage Rating A = 48V C = 6V Enclosure = Open Panel 1 = Type 1 A = Standard NEMA General Purpose Part Numbering System KMG 13 A 1 A KMG 13 A G1 Series Current Rating Voltage Rating A = 48V C = 6V Enclosure G1 = GP Indoor G3R = GP NEMA 3R Options L = Lugs, = No Lugs B = Monitor Board, = No Monitor Board S = Thermal Switch, = No Thermal Switch H = Space Heater, = No Space Heater Product Specifications Carrier frequencies from 2 khz to 12 khz Short Term Overload Rating: Tolerance 2% rated I for a minimum of 3 minutes System Voltage: 48 VAC, 6 VAC Insulation System: Class H (18 C) or Class R (22 C) Temperature Rise: 115 C or 155 C Ambient Temperature: Open Panel 5 C (122 F) Enclosed Panel 4 C (14 F) Distance: up to 15, feet Voltage Distortion: < 5% (typical) Agency Approvals: Industrial - cul, UL Enclosures: Industrial Version: UL Open, UL Type 1 General Purpose: NEMA 1 and 3R Low Voltage PWM Power Supply to Medium Voltage Motor DRIVE DRIVE Motor Guard STEP-UP XFMR Block Diagram Test Stand Motor Guard Multiple Motor Applications DRIVE MOTOR PERFORMANCE GUARANTEE Properly sized and applied, the addition of a MotorGuard Output Filter is guaranteed to bring the application into compliance with NEMA Standards Publication No. MG-1. If the system fails to meet MG-1 standards with the addition of a MotorGuard filter, TCI will take back the output filter and pay shipping both ways. This offer is valid for 6 days from the installation date. DRIVE Motor Guard MOTOR MOTOR MOTOR Extreme Long Lead Applications DRIVE Motor Guard MOTOR

20 MOTORGUARD TYPICAL APPLICATIONS Extreme long motor lead lengths. Applications can reach 15, feet Low voltage PWM power supply to medium voltage motor Multiple motor applications such as conveyors, blowers, pumps, and fans Test floor and test stand applications Shore to ship power for non-6 Hz systems HVAC systems to reduce audible noise Additional Power Quality Solutions: HarmonicGuard Active (HGA) Filter Helps meet IEEE-519 Reduces current harmonic distortion to less than 5% at full load Actively monitors system current, improves power factor to near unity Built-in touchscreen display & Modbus RTU Copyright 215 Part Number: Version 1.5 HarmonicGuard Passive (HGP) and HarmonicGuard HG7 Filters Helps meet IEEE-519 Improves power factor The HGP limits current harmonic distortion to less than 5% over a wide load range The HG7 reduces current harmonic distortion to less than 7% at full load KDR Line Reactor Prevents nuisance tripping Protects the source by lowering current distortion created by the drive V1k Motor Protection Output Filter Protects the motor and cable from voltage spikes due to high dv/dt and excessive cable capacitance Helps stop motor insulation breakdown Protects cable runs (up to 3, feet) and reduces motor heating, noise and vibration KRF EMI/RFI Filter Filter EMI/RFI noise caused by power switching devices Meet FCC regulation 15, subpart J Prevents interference with automated lighting circuits, security cameras, and other critical electronics TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Please contact us about specific products and services. Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filters

21 Motor Protection MotorShield Sinewave Output Filter As Pulse Width Modulated (PWM) Drives are incorporated into various applications and processes, the increased energy savings and decreased maintenance on drives can be offset by increases in motor failures. High voltage spikes caused by a phenomenon known as reflected wave (dv/dt) occur when there are long cable runs between the drive and the motor. The impedance on either end of the cable run does not match, causing voltage pulses to be reflected back in the direction from which it arrived. As these reflected waves encounter other waves, their values add, causing higher peak voltage. Peak voltages on a 48V system can reach 1,6V. These high peak voltages will cause a rapid breakdown of motor insulation, leading to motor failure. Industry Application: Fans & Pumps The MotorShield is designed to extend motor life in variable torque applications such as fans and pumps with lead lengths up to 15, feet. Motors on these systems typically produce a large amount of heat as they run. The MotorShield is the perfect solution to prevent overheating and motor failure. Typical Applications Wastewater Treatment Plants Mining Material Handling Oil & Gas HVAC Systems Chemical Processing Power Plants Data Centers Renewable Energy Pulp & Paper Motor Input Waveform Without MotorShield 15 TCI s MotorShield TM improves system performance by protecting the motor from the harmful effects of reflected waves and preventing motor failure associated with insulation failure, overheating, and noise. Volts Motor Input Waveform With MotorShield Volts

22 Technical Specifications Current Ratings VFD Output Voltage VFD Output Frequency VFD Carrier Frequency Filter Performance 48V: 9 to 18 amps 6V: 8 to 5 amps Intermittent current: 15% for 1 minute out of every 6 minutes Up to 48 V, 3-phase, at fundamental base frequency configured to Volts per Hz Up to 8 Hz 2 khz to 16 khz Maximum peak voltage of output waveform - 48 V: 1V Maximum dv/dt of output waveform - 48 V: 5V/μs Environmental Conditions Maximum Elevation 3,3 ft (1, m), derating required for operation above this level Ambient Operating Temperature Range -3 C (32 F) to 4 C (14 F) Cooling provisions required for operation above this temperature Ambient Storage Temperature Range -4 C (-4 F) to 5 C (122 F) Maximum Humidity, Operating or Storage 95%, non-condensing Reference Technical Standards Enclosure Options NEMA 1/3R enclosure Insertion Impedance 6.5% nominally at 6 Hz & full load current Capacitors High endurance design (no PCBs) Agency Approvals UL & cul Listed (up to 48 amps) Part Numbering System Series: UL Rating: MSD - UL 58 MSN - Non-UL Current Rating: Voltage Rating: A - 48 V C - 6 V Enclosure: 3 - Type 1 / 3R Option: - Default MS D 1 6 A 3 Extreme Long Lead Applications MOTOR VFD Multiple Motor Applications MOTOR MOTOR MOTOR VFD Low Voltage PWM Power Supply to Medium Voltage Motor VFD STEP-UP XFMR MOTOR Performance Guarantee Properly sized and applied, the addition of a MotorGuard Sinewave Output Filter is guaranteed to bring the application into compliance with NEMA Standards Publication No. MG-1. If the system fails to meet MG-1 standards with the addition of a MotorGuard filter, TCI will take back the output filter and pay shipping both ways. This offer is valid for 6 days from the installation date. TCI, LLC transcoil.com W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #2944 Version 1.4 Copyright 215

23 Motor Protection dv/dt Output Filter The benefits of installing a Pulse Width Modulated (PWM) Drive, including increased energy savings and decreased maintenance, may make it seem like the perfect solution. But, these benefits can be offset by increases in motor failures. Voltage wave reflection is a function of the voltage rise time (dv/dt) and the length of the motor cables. The impedance on either end of the cable run does not match, causing voltage pulses to be reflected back in the direction from which it arrived. As these reflected waves encounter other waves, their values add, causing higher peak voltage. As wire length or carrier frequency increases, the overshoot peak voltage also increases. Peak voltages on a 48V system can reach 1,6V and 2,1V on a 6V system. These high peak voltages can cause a rapid breakdown of motor insulation, leading to motor failure. Superior Design, Proven Results By combining a patented dampening circuit with a low pass filter, V1k filters increase the voltage rise time (dt out of dv/dt) thereby preventing voltage spikes from exceeding 1, V, and protecting motor and cable insulation. With thousands of successful applications worldwide, the V1k is a proven reliable solution with its industry leading performance and benefits: Extend the life of your motor & cable by reduction of harmful voltage spikes due to dv/dt. Protect cable runs and reduce motor heating, noise and vibration. Prevent motor failure with protection against motor insulation breakdown. Reduce Common Mode by a minimum of 3%. Improve system productivity and increase bearing life and up-time. Protect long lead lengths up to 3, feet (depending on cable and VFD size). Typical Applications Oil and Gas Pumps Irrigation Field, Farms Wa s t ew a t e r Tre a t m e n t P l a n t s HVAC Pulp, Paper

24 Technical Specifications Technical Characteristics Ratings 2-75 amps; 24 V - 6 V Carrier Frequency 1-12 khz Insulation Rating 6 V Class Insulation Class Class H (18 C) or Class R (22 C) Efficiency 98% Lead Length Specific applications can reach 3, feet (consult factory for applications above 1,5 feet) Fundamental Frequency -6 Hz (consult factory for applications over 8 khz and/or 6-12 Hz fundamental if the cable lengths exceed 4 feet) Environmental Conditions Operating Temperature Enclosed: 4 C (14 F) Operating Altitude 2, m (6, ft) Derating necessary above 2, m Reference Technical Standards Agency Approvals UL & cul Protection (enclosure) Open, UL Type 1, UL Type 3R Warranty One year of useful service, not to exceed 18 months from date of shipment. Operation possible up to 12 Hz output drive frequency with derating (contact factory for details). Voltage Without V1k 15 Common Mode Without V1k 1 Volts feet Voltage With V1k 15 Per Unit Current Common Mode With V1k 1 Volts feet Per Unit Current Multiple Motor Applications MOTOR MOTOR MOTOR VFD Please see web site for configuration guidelines. Performance Guarantee Properly sized and applied, TCI guarantees that the V1k will limit motor terminal peak input voltage to 15% of the bus voltage with a wire lead length of 1, feet and a carrier frequency of 4 khz. Maximum lead length and carrier frequency can vary depending on wire lead type. If a properly selected, installed and loaded V1k filter fails to meet the guaranteed performance levels, TCI will provide the necessary components or replacement filter at no additional charge. TCI does not take responsibility for additional installation or removal costs to include, but not limited to, replacement of third party equipment. Please see TCI s website for minimum requirements. TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #25383 Version 1.6 Copyright 215

25 Harmonics & Power Quality KDR Line Reactor Variable frequency drives (VFD) are beneficial to a wide range of applications, but contain a power conversion process that creates current and voltage distortion, known as harmonics. Issues caused by harmonics may include: Transformer and distribution equipment overheating Random breaker tripping Sensitive equipment failure Poor power factor KDR Line Reactor The KDR Line Reactor offers impedance against the flow of harmonics and other high frequencies that can cause tripping and equipment failure. Drives and other sensitive devices are protected by the KDR from electrical distortion on the line including harmonics. Harmonic Current Distortion Without KDR 3 2 Advantages of the KDR Line Reactor Extend the life of the motor on the output of the VFD Protect other equipment on the line from operational issues caused by voltage distortion Dramatically increase drive uptime by reducing the likelihood of the drive tripping Improve power factor Reduce motor heating and audible noise Increase system productivity Meet IEEE Typical Applications Pulp & Paper Machining Wastewater Treatment Plants Oil & Gas HVAC Systems Irrigation Fields, Farms Extruders Steel Industry Warranty Every TCI line reactor is manufactured in Wisconsin with high quality materials and is backed by a lifetime warranty.* Amps Transient Voltage Without KDR Harmonic Current Distortion With KDR Bus Volts Amps Transient Voltage With KDR Bus Volts Manufactured in Germantown, Wisconsin

26 Technical Specifications Environmental Conditions Operating Temperature Operating Altitude Reference Technical Standards Agency Approvals Fundamental Frequency Impedance Protetion System Voltage Short Term Overload Rating Inductance Characteristics Input and Output Protection (enclosure) DIN Rail version available Open: 5 C (122 F) Enclosed: 4 C (14 F) 2, m (6, ft) Derating necessary above 2, m cul, UL; UL Recognized, CE Marked 5/6 Hz Low Z and High Z 28/24 VAC, 48 VAC, 575/6 VAC, 69 VAC Tolerate 2% rated I for a minimum of 3 minutes Minimum 95% L at 11% Load Minimum 8% L at 15% Load Available for either the line or load side of a VFD Open, UL Type 1, UL Type 3R See website for details Impedance Options KDR Line Reactors have been designed to provide the best protection for both your drive and your application. KDR Optimized Drive Reactors are available in two ratings versions, Low Z (low impedance) and High Z (high impedance). Input impedance can significantly improve drive performance. Select impedance based on the guidelines below: Use KDR Low Z Units For: Any application where either a 1.5% or 3% reactor would be applied. Reduction of nuisance tripping caused by: Transient voltages caused by capacitor switching Line notching DC bus overvoltage tripping Inverter overcurrent and overvoltage Additional benefits include: Lowering injected percentage of harmonic current Improving true power factor Reducing cross-talk between drives Adding impedance to drives with DC link chokes/ reactors when more impedance is desired due to a relatively stiff source Performance Guarantee Properly sized for the application, a KDR reactor is guaranteed to eliminate any AC drive overvoltage tripping problems. If a KDR reactor is installed and the tripping problem remains, TCI will take back the reactor and pay shipping both ways. (Offer valid for 6 days from date of shipment.) Use KDR High Z Units For: Any application where a 5% reactor would be applied. KDR High Z offers the same superior benefits as Low Z plus additional benefits which include: Helping prevent drive component damage Providing maximum harmonic mitigation without adding capacitance Part Numbering System KDR Series UL Listed (Blank if UL Recognized) Design Frame Sequence Code Impedance Rating L = Low Impedance H = High Impedance P = Output Reactor Enclosure E1 = UL Type 1 E3R = UL Type 3R KDR UL A 55 H E3R *For the life of the drive TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Part #2332 Version 1.5 Copyright 215

27 3-PHASE EMC POWER LINE FILTER KRF Limits high frequency noise Reduces interference Protects sensitive equipment Eliminates drive cross-talk Meet FCC Regulation 15, Subpart J Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filters

28 3-PHASE EMC POWER LINE FILTER KRF Before KRF Non-Linear Loads can draw harmonic current from the source, resulting in harmful high frequency noise There are many pieces of equipment that can generate EMI (electro magnetic interference), variable frequency drives included. In the case of variable frequency drive, the electrical noise produced is primarily contained in the switching edges of the PWM controller. Increases in switching frequencies also increase the effective edge frequencies produced, thereby increasing the amount of electrical noise. Reduce High Frequency Distortion KRF filters use a combination of high frequency inductors and capacitors to reduce noise in the critical 15 khz to 3 MHz frequency range. The inductors act as open circuits and the capacitors act as short circuits at high frequencies while allowing the lower power line frequencies to pass untouched. KRF filters assist with cost effective compliance to EMC directives, in a compact, efficient, light-weight design. The high common mode and differential mode reduction in the critical 15 khz to 3 MHz frequency range ensures that potential interference from AC drives is reduced or eliminated. After KRF EMI (Electro Magnetic Interference) RFI (Radio Frequency Interference) The terms EMI and RFI are often used interchangeably. EMI is actually any frequency of electrical noise, whereas RFI is a specific subset of electrical noise on the EMI spectrum. Conducted EMI is unwanted high frequencies that ride on the utility AC wave form. Incorrect Interconnection Layout Correct Interconnection Layout KRF Filter KRF Filter To Line Ground VFD To Line and Load Note: Connect ground to main ground bus VFD To Load

29 Part Numbering System K RF 18 A CB K-Series 3 - Phase EMI/RFI Filter Max Current (amps) Voltage Rating A = 48V V = 69V Termination TB = Termination Block CB = Copper Bus Equipment Interference and Failure The power line noise emissions associated with variable frequency drives can cause disturbances in nearby equipment. Typical disturbances include: Dimmer and ballast instability Lighting disturbances such as flashing Poor radio reception Instability of control systems Flow metering fluctuation Computer system failures Remote I/O glitches Encoder feedback errors Nuisance faults PLC Analog meter bouncing Thermostat control problems Product Specifications 3-Phase System Voltage: 48 VAC (applied to 24 VAC - 52 VAC) 69 VAC (applied to 6 VAC - 76 VAC) Amp Ratings: 48V (8-25) 69V (25-25) Fundamental Frequency: 5/6 Hz Units to accommodate up to 2,5 amps Filtering: Advanced two-stage filtering design Warranty: 1 year Ambient Temperature: -25 to 1 C Maximum Altitude: 1, meters (3, feet) Derating necessary above 1, meters Short Term Overload Rating: 15% rated I for 3 minutes or 25% for 3 seconds Tested Value: 1% tested for Hipot, ground continuity, input-output continuity and insertion loss characteristic Agency Approvals: ENEC, UR & cur Typical Circuit Diagram

30 KRF Typical Applications Motor drives Elevators Commercial Buildings Wind farms Photovoltaics UPS Power supplies Additional Power Quality Solutions: HarmonicGuard Active (HGA) Filter Helps meet IEEE-519 Reduces current harmonic distortion to less than 5% at full load Actively monitors system current, improves power factor to near unity Built-in touchscreen display & Modbus RTU Copyright 215 Part Number: Version 1.5 HarmonicGuard Passive (HGP) and HarmonicGuard HG7 Filters Helps meet IEEE-519 Improves power factor The HGP limits current harmonic distortion to less than 5% over a wide load range The HG7 reduces current harmonic distortion to less than 7% at full load KDR Line Reactor Prevents nuisance tripping Protects the source by lowering current distortion created by the drive MotorGuard TM and MotorShield TM Sinewave Output Filters Protects the motor by converting the PWM waveform into a near sinusoidal wave Prevents voltage overshoots that cause early degradation of insulation systems in motors, transformers, and cables Extends motor life by reducing operating temperature V1k Motor Protection Output Filter Protects the motor from voltage spikes due to dv/dt Helps stop motor insulation breakdown Protects cable runs (up to 3, feet) and reduces motor heating, noise and vibration TCI, LLC W132 N1611 Grant Drive Germantown, WI 5322 USA Toll Free: P: F: Please contact us about specific products and services. Line Reactors Harmonic Filters EMC Filters dv/dt Filters Sinewave Filter

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved

More information

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute

More information

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,

More information

Power Quality Solutions

Power Quality Solutions Power Quality Solutions What is Power Quality? For electrical systems to function in their intended manner without significant loss of performance or life, they require a supply of electricity that is

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. Harmonic Mitigation for Variable Frequency Drives HWEA Conference February 15, 2011 Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. 1 OVERVIEW Linear vs. Non- Linear Load Definitions AC Drive Input Current Harmonics

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse ADJUSTABLE SPEED DRIVES HX7 Series 18-Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation Variable Frequency Drive Packages with Harmonic Mitigation Low Harmonic Drive Packages Engineered by Rockwell Automation What Do I Need to know About Harmonics? What are Harmonics? Harmonics are deviations

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

Phoenix DX Clean Power (18 Pulse) AC Drive

Phoenix DX Clean Power (18 Pulse) AC Drive PHOENIX DX Phoenix DX Clean Power (18 Pulse) AC Drive Poor power quality can be costly. Nonlinear loads, including AC Drives, introduce undesirable harmonic currents into the power system that can damage

More information

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse ADJUSTABLE SPEED DRIVES W7 Series 18 Pulse Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating

More information

Effective Harmonic Mitigation with Active Filters

Effective Harmonic Mitigation with Active Filters Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web:  - ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

Harmonic Distortion and Variable Frequency Drives

Harmonic Distortion and Variable Frequency Drives Harmonic Distortion and Variable Frequency Drives Definitions Variable Frequency Drives (VFDs); sometimes referred to as variable speed drives. Harmonic Distortion is a measure of the amount of deviation

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

Technical Paper. Harmonic Distortion in Data Centers

Technical Paper. Harmonic Distortion in Data Centers Technical Paper Harmonic in Data Centers Written By: Ian Wallace Summary Power quality and power reliability are critical to data center operation. As strides have been made to improve energy efficiency

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS Highly Efficient, System-Designed Solutions for Harmonic Distortion Introducing Danfoss Advanced Harmonic Solutions (AHS) Danfoss

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

The Reflective Wave Phenomenon dv/dt and Reflective Wave unsuppressed causes Motor failures

The Reflective Wave Phenomenon dv/dt and Reflective Wave unsuppressed causes Motor failures TCI s KLC & KLCUL dv/dtguard Output Filters Provide Superior Patented Protection for Motors s the technology of Pulse Width Modulated (PWM) Drives are incorporated into various applications and processes,

More information

Active Harmonic Filter

Active Harmonic Filter Reactive Power and Harmonic Compensation Active Harmonic Filter The new StacoSine Plus active harmonic filter is available in 100, 150, 200 and 300 amp assemblies. Modules can be paralleled for a maximum

More information

High Frequency SineWave Guardian TM Filter

High Frequency SineWave Guardian TM Filter High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference

More information

How Harmonics have led to 6 Power Factor Misconceptions

How Harmonics have led to 6 Power Factor Misconceptions Harmonic and Energy Saving Solutions How Harmonics have led to 6 Power Factor Misconceptions Tony Hoevenaars, P.Eng. Power Factor Misconceptions 1. Low power factor is normally caused by electric motors

More information

KRF EMC Filters Installation, Operation and Maintenance Manual

KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters limit high frequency noise, as well as: Reduce interference Protect sensitive equipment Eliminate drive cross-talk Meet FCC

More information

Challenges of Parallel Operations

Challenges of Parallel Operations GENLINK TM issimilar Pitch Limiter Key Features Inserts >40% impedance in neutral current circulating path Reduces neutral circulating current by >75% Adds

More information

7/15/2002 PP.AFD.08 1 of 28

7/15/2002 PP.AFD.08 1 of 28 Power Quality Considerations When Applying Adjustable Frequency Drives Explanations and Various Countermeasures 7/15/2002 PP.AFD.08 1 of 28 Power Quality Why the Renewed Interest in Power Quality? Copy

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

Thyristorised Automatic Power Factor

Thyristorised Automatic Power Factor Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor

More information

MTE training MTE Corporation

MTE training MTE Corporation 1 MTE Corporation Improving the Performance and Reliability of Power Electronic Systems 2 MTE solutions to Long lead dive applications Protection of motors drive cables and Variable frequency inverters

More information

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement PQ01 Harmonic Solutions for VFD s Review of Power Control Harmonics, Power Factor, Distortion & Displacement Related Content at the Expo PQ02 Power Quality and Monitoring.. PQ03 Using Test Eqipment to

More information

LINEATOR. Advanced Universal Harmonic Filter

LINEATOR. Advanced Universal Harmonic Filter R International Inc. LINEATOR Patented Revolutionary New Reactor esign Advanced Universal Harmonic Filter Wide Spectrum Harmonic Filter for treatment of all harmonics generated by 3-phase diode or thyristor

More information

Lineator-HP High Performance model used where the highest power quality demands must be met

Lineator-HP High Performance model used where the highest power quality demands must be met LINEATOR TM Advanced Universal Harmonic Filter The LINEATOR Advanced Universal Harmonic Filter (AUHF) is a revolutionary advancement in the area of passive harmonic mitigation. No other device on the market

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

External Drive Hardware

External Drive Hardware US1086e_External Drive Hardware, 08/2010 External Drive Hardware Selection and Application Answers Answers to external hardware questions A soup to nuts list of questions with installation / application

More information

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives .0 Volume 6 Solid-State Control CA0800007E March 05 www.eaton.com V6-T-47 .0 Adjustable Frequency Drives Overview What Are Harmonics? Take a perfect wave with a fundamental frequency of 60 Hz, which is

More information

Drives 101 Lesson 5. Power Input Terminology for a VFD

Drives 101 Lesson 5. Power Input Terminology for a VFD Drives 101 Lesson 5 Power Input Terminology for a VFD This lesson covers the terminology associated with the incoming power to a Variable Frequency Drive (VFD) and the efforts to protect both the VFD and

More information

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N Harmonic Basics 3 rd Harmonic Fundamental 5 t1h Harmonic 7 th Harmonic Harmonic

More information

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors. and Drives Control R Interface OBICON Perfect Harmony Short overview 14.03.2007 1 System overview Product features Truly Scaleable Technology 300 kw to 30 MW (Single Channel) Large Number of Framesizes

More information

PowerGard Series C 18-Pulse Enclosed Drive Controllers

PowerGard Series C 18-Pulse Enclosed Drive Controllers PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive and power quality solutions PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive

More information

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM Abstract Efficient operation of the electrical system of any facility is essential to controlling operational costs while maximizing

More information

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products

More information

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES FS1 ADJUSTABLE SPEED DRIVES FS1 Now Available With LonWorks BACnet & MetasysN2 FS1 Model FLA & Dimensions (in.)/ Weight (lbs.) VOLTAGE HP MODEL NUMBER FLA FRAME Dimensions (in.) SHIPPING H W D WEIGHT (lbs.)

More information

PowerFlex 400 Submittal

PowerFlex 400 Submittal PowerFlex 400 Submittal Submittal Date: Project Name: Project Location: Consulting Engineer: Contractor: Contractor PO #: Distributor Name: Distributor Contact: Distributor Reference #: Note: This is general

More information

McGill Power Sales & Engineering, INC.

McGill Power Sales & Engineering, INC. 1 McGill Power Sales & Engineering, INC. Power Factor Correction Terry McGill President McGill Power Sales & Engineering Inc. 2007 Eaton Corporation. All rights reserved. Agenda What is power factor? What

More information

Reducing Total Harmonic Distortion with Variable Frequency Drives

Reducing Total Harmonic Distortion with Variable Frequency Drives Reducing Total Harmonic Distortion with Variable Frequency Drives Low Harmonic Technology in Optidrive Eco Overview Overview Both AC line chokes and DC link chokes have historically been used with Variable

More information

APPLICATION GUIDE. Harmonics in HVAC applications

APPLICATION GUIDE. Harmonics in HVAC applications APPLICATION GUIDE Harmonics in HVAC applications Table of contents 4 Harmonics in general and why we should care 4 Introduction 4 Basics of harmonics 5 Causes of harmonic distortion 5 Problems caused

More information

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications: Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of

More information

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS. MAIN TOPICS DISCUSSED Electric Rates Electrical system utilization ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K Power quality Harmonics Power factor (Cos phi) improvement Section K - 2 ELECTRIC

More information

VARIABLE FREQUENCY DRIVE

VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE Yatindra Lohomi 1, Nishank Nama 2, Umesh Kumar 3, Nosheen aara 4, Uday Raj 5 (Assistant Professor in Department of Electrical Engineering GIET Kota2) (Department of Electrical

More information

ULTRA-K Series 600K - he

ULTRA-K Series 600K - he 5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services edarat group INTRODUCTION Harmonics are a mathematical way of describing distortion

More information

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics Power IT LV Active Filters PQFI PQFM PQFK The ABB comprehensive solution for active filtering of harmonics Harmonics and Power Quality Power Quality relates to the amplitude, frequency and distortion of

More information

Power-Sure 700. Technical Data TD158001EN. Contents

Power-Sure 700. Technical Data TD158001EN. Contents Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...

More information

Lineator-HP High Performance model used where the highest power quality demands must be met

Lineator-HP High Performance model used where the highest power quality demands must be met LINATOR TM Advanced Universal Harmonic Filter The LINATOR Advanced Universal Harmonic Filter (AUHF) is a revolutionary advancement in the area of passive harmonic mitigation. No other device on the market

More information

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner conditioning products Electronic voltage regulator -Sure 700 & 800 -Suppress T7 & 100 Harmonic correction unit Sag ride-through power conditioner The power to work Basics of power quality The partner you

More information

PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer

PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer Transformerless drives help industry reduce the cost of motor control while using standard motors.

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

The new Yaskawa Varispeed G7 Inverter

The new Yaskawa Varispeed G7 Inverter The new Yaskawa Varispeed G7 Inverter Unique new 3-level PWM flux vector Constant or variable torque applications control method 0.4 kw to 300 kw power range Exceptional low speed/high torque control Quick

More information

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and

More information

Power IT LV Active Filters PQFA - PQFL - PQFT

Power IT LV Active Filters PQFA - PQFL - PQFT Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable

More information

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017 Harmonics and Their Impact on Power Quality Wayne Walcott Application Engineering Manager June, 2017 Presentation Overview A little about harmonics What are harmonics What are NOT harmonics What creates

More information

The Reflective Wave Phenomena

The Reflective Wave Phenomena Application Note The Reflective Wave Phenomena Rev2.doc The Reflective Wave Phenomena Note to Specifiers This application note contains Cutler-Hammer s recommendations for the application of filters for

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network AccuSine PCS Active Harmonic Filter Cruise through rough waves in your electrical network How Can Active Harmonic Filters Solve Power Quality Issues in Your Facility? Power electronic devices that have

More information

GE Energy. Matrix Harmonic Filter Series D

GE Energy. Matrix Harmonic Filter Series D GE Energy Matrix Harmonic Filter Series D Matrix Harmonic Filter GE Matrix Harmonic Filters provide broadband reduction of harmonics. Matrix Harmonic Filters not only offer better performance over other

More information

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution Harmonic Solutions in Electrical Systems Raed Odeh Application Specialist - Power Quality & Electrical Distribution Agenda I. Harmonic Basics II.Harmonic Mitigation Solutions III.Case Study 2 Harmonic

More information

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection: Utility Systems Technologies, Inc. Sag Fighter TM Deep Voltage Sag Protection: D e e p Vo l t a g e S a g P r o t e c t i o n For three phase application: Q u a l i t y P o w e r. B e t t e r B u s i n

More information

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network AccuSine PCS Active Harmonic Filter Cruising through rough waves in your electrical network The Schneider Electric AccuSine power correction system (PCS) injects harmonic current to cancel harmonic current

More information

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE - 519 Solutions Harmonics Tutorial 1 Power Conversion Equipment can save energy and control motors, heaters,

More information

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter PFCC-1000 series Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter Powerful Flexibility Durability - Quality email.us.at:.quotes@tanddproducts.com www.tanddproducts.com

More information

Reduce harmonics in HVAC&R inverters through C-Less technology

Reduce harmonics in HVAC&R inverters through C-Less technology Reduce harmonics in HVAC&R inverters through C-Less technology Karim Lamrabtine Global Product Manager VSD 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net What are Harmonics? Standards Compliance How

More information

General Purpose Drives

General Purpose Drives AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase

More information

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion Harmonic Solutions Clean Power Drive Solution to Harmonic Distortion UTILITY GRID UTILITY SWITCH YARD IN THE FACILITY IEEE-519 POINT OF COMMON COUPLING POWER PLANT GENERATION TRANSMISSION MEDIUM VOLTAGE

More information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17 Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................

More information

Understanding Input Harmonics and Techniques to Mitigate Them

Understanding Input Harmonics and Techniques to Mitigate Them Understanding Input Harmonics and Techniques to Mitigate Them Mahesh M. Swamy Yaskawa Electric America YASKAWA Page. 1 Organization Introduction Why FDs Generate Harmonics? Harmonic Limit Calculations

More information

Power Factor. Power Factor Correction.

Power Factor. Power Factor Correction. Power Factor. Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator) PRODUCT SPECIFICATION FOR A 15 THRU 500 kva, THREE PHASE, MODULAR POWER REGULATOR AND CONDITIONER PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator) 1.0 General This specification covers the electrical

More information

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD) Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics

More information

Introduction: TAS PowerTek Ltd. MAVROS

Introduction: TAS PowerTek Ltd. MAVROS Introduction: Electrical supply system in today s scenario faces a major challenge due to Power Quality issues. Harmonics on supply system due to Electronics type of loads that are used extensively. Power

More information

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 8 PART 1 GENERAL 1.1 SCOPE.1 This specification shall apply to the materials, design, fabrication, inspection, and testing of 600 V Variable Frequency Drives (VFD)

More information

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG PRODUCT CATALOG M O T O R & G E N E R A T O R P R O T E C T I O N BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG Why Your Equipment Needs MEG-ALERT Protection 1 2 3 4 5 6 7 How can you be sure

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller

More information

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage

More information

VFDs and Harmonics in HVAC Applications

VFDs and Harmonics in HVAC Applications VFDs and Harmonics in HVAC Applications Larry Gardner Product Marketing Manager Yaskawa America, Inc. Jeff Grant Senior Sales Engineer LONG Building Technologies October 20, 2016 2016 Yaskawa America,

More information

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Harmonics, its Mitigation & Result of Case study of Spinning Mill International Journal of Innovative Research in Engineering & Management (IJIREM) ISSN: 2350-0557, Volume-2, Issue-4, July 2015, its Mitigation & of Case of Spinning Mill Yogesh Subhash Shimpi M. Tech

More information

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION Nominal Input Voltage Max. Output Power Nominal Output Voltage Max. Output Current 120/277 Vac 12, 24, Vdc 5, 3.92 A Efficiency up to 90% typical Max. Case Temperature 100 C (measured at the hot spot)

More information

Harmonics White Paper

Harmonics White Paper Harmonics White Paper New Breakthrough In PWM Drives Technology Reduces Input Line Harmonics Without the Use of Filtering Devices Harmonic Distortion Damages Equipment and Creates a Host of Other Problems

More information

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General

More information

Application Note. Applicable Product: AC Drives

Application Note. Applicable Product: AC Drives Application Note Application Note Guidelines For The Use Of 400-600 Volt AC Drives In Medium Voltage Applications Applicable Product: AC Drives 4kV Step-down Transformer AC Drive 400-600V Output Filter

More information

Generator Advanced Concepts

Generator Advanced Concepts Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves

More information

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric ADJUSTABLE SPEED DRIVES VF-S11 The Next Generation of Micro Inverters is Here. The S11 provides maximum torque with precise speed control. It features an easy-to-use, quiet and compact design. In addition,

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

Do Capacitor Switching Transients Still Cause Problems?

Do Capacitor Switching Transients Still Cause Problems? Do Capacitor Switching Transients Still Cause Problems? Mark McGranaghan We have been evaluating problems related to capacitor switching transients for many years. Capacitor banks have been used on distribution

More information

Harmonic Filters for Single Phase Equipment

Harmonic Filters for Single Phase Equipment POWER QUALITY Harmonic Filters for Single Phase Equipment Agriculture Call Centers Casino Slot Machines Computer Centers Distributed Generation Electronic Power Converter Oil & Gas On-Line UPS Power Electronics

More information