Session: 1E CONTRAST AGENTS II Chair: K. Ferrara University of California-Davis. 1E-1 10:30 a.m.

Size: px
Start display at page:

Download "Session: 1E CONTRAST AGENTS II Chair: K. Ferrara University of California-Davis. 1E-1 10:30 a.m."

Transcription

1 Session: 1E CONTRAST AGENTS II Chair: K. Ferrara University of California-Davis 1E-1 10:30 a.m. PULSE INVERSION DOPPLER FOR BLOOD FLOW DETECTION IN THE MACRO- AND MICRO-VASCULATURE WITH ULTRASOUND CONTRAST AGENTS M. BRUCE* 1,S.JENSEN 2,M.AVERKIOU 2,andJ.POWERS 2, 1 University of Washington, and 2 Philips Ultrasound. Corresponding mbruce@u.washington.edu Visualization of macro-vessels is difficult using existing contrast agent imaging methods without blooming or other artifacts. Early use of standard color flow equipment led to saturation and blooming, obscuring small vasculature. More recently, low Mechanical Index (MI<0.15) harmonic techniques have been devised to visualize nearly stationary microbubbles in the microcirculation in real time (frame rates>8hz). These methods provide a fleeting view of the larger feeding vessels at the beginning of a bolus before the microcirculation fills obscuring their view ( 5-10 secs). Moderate power techniques (MI ) are used to visualize the macrovasculature by destroying the bubbles in the microcirculation, but then perfusion is lost. We present a method using a low-mi pulse-inversion acquisition with ultrasound contrast agents, which enables the simultaneous visualization of blood flow in both the macro- and micro-vasculature. A combination of RF and Doppler filters enables the separation of the fundamental and harmonic flow components from tissue and stationary microbubbles. These flow signals are combined with conventional pulse inversion processing to make an image displaying both perfusion and flow. Using Definity at an MI of 0.07, this technique was compared against color flow without contrast for the detection of macrovascular blood flow in a human liver. Scanning at low MI reduced clutter in the fundamental and harmonic signals compared to high MI color flow by 25 db and 45 db respectively. Adding the contrast agent, even at very low MI, increased flow signals relative to color flow for the two components up to 15 db and 4 db, respectively. This gives overall improvement of flow to clutter ratios of 40 db and 49 db for the fundamental and harmonic components respectively, yielding improved flow sensitivity and penetration. 182

2 1E-2 10:45 a.m. DETECTION OF HARD-SHELLED ULTRASOUND CONTRAST AGENTS USING A SIGNAL SUBTRACTION METHOD S.H.BLOCH*,D.N.PATEL,P.A.DAYTON,M.WAN,andK.W.FERRARA, Department of Biomedical Engineering, UC Davis. Corresponding shbloch@ucdavis.edu Hard-shelled contrast agents demonstrate unique properties because the enclosed gas oscillates freely only after the shell is damaged. We have observed this behavior optically using a high-speed camera, and here we exploit this property to improve the ultrasound differentiation of hard-shelled microbubbles and tissue. Previous investigations have shown that microbubbles can be detected using phase inversion techniques. If one-cycle pulses are transmitted, the 180 (rarefaction-first) bubble echo contains harmonics while the 0 (compressionfirst) echo does not. This effect does not depend on the order of pulse transmission in flexible-shelled bubbles. However, we have previously reported that a submicron polymer-shelled agent, M1091, does exhibit order-dependent effects: the first echo is lower in amplitude and higher in frequency than the second echo, regardless of transmitted phase. We have now confirmed these effects using a second polymer-shelled agent, BG1135, and believe these to be general properties of hard-shelled microbubbles, whose response to the first ultrasound pulse includes the disruption of the microbubble shell. Based on these findings, we were able to design a pulse sequence to detect hard-shelled bubbles, signal subtraction, in which two same-phase single-cycle pulses are transmitted in succession and the resulting echoes subtracted. This subtraction results in the cancellation of tissue echoes even in the presence of tissue harmonic generation, with only a small reduction in bubble signal amplitude. Using 2.25 MHz, 1 MPa pulses with 180 phase, we achieved agent-to-tissue ratios exceeding 30 db, compared to less than 20 db for single-cycle phase inversion. We have studied the effectiveness of this technique relative to changes in pressure, transmitted frequency, and bubble and tissue motion. This research was supported by POINT Biomedical Corp., Bracco Research S.A., and NIH grant CA The authors thank Peter Frinking of Bracco Research, and Robert Short and Glenn Tickner of POINT Biomedical for their assistance. 1E-3 11:00 a.m. IN-VITRO B-MODE CONTRAST IMAGING USING CHIRP EXCITATION WITH A NON-LINEAR DECODER J. BORSBOOM*, C. TING CHIN, and N. DE JONG, Erasmus MC, Rotterdam, The Netherlands. Corresponding j.borsboom@erasmusmc.nl Coded excitation using chirps is used in ultrasound imaging to increase signal-tonoise ratio (SNR) and penetration depth. Previously, we proposed a non-linear 183

3 compression filter that can selectively compress and extract the fundamental and second harmonic parts of received echoes and obtain axial resolutions comparable to conventional imaging. In this study, we investigated whether non-linear contrast imaging with chirp excitation improves 2-D image quality due to increased SNR and increased contrast-to-tissue ratio (CTR). To quantitatively evaluate the performance of the non-linear coded excitation technique, we made B-mode images of a flow phantom using pulse and chirp excitations in both fundamental and second harmonic mode and compared the results by eyes, SNR and CTR. The flow phantom consisted of tissue-mimicking material with embedded flow channels of 10 mm, 5 mm, and 1 mm diameters in which either saline or an experimental contrast agent (BR14, Bracco Research SA, Geneva, Switzerland) was flowing. For scanning we used a 3.5 MHz, 65% bandwidth unfocussed transducer in pulse-echo mode excited with 0.98 µs Gaussian pulses and 10 µs Gaussian apodised chirps, both with centre frequency 2 MHz, 45% bandwidth and, MI s up to The transducer was mechanically scanned over the surface of the phantom. The echoes were digitized and recorded with a LeCroy digital oscilloscope and processed off-line. The resulting 2-D images showed the 10 and 5 mm channels in both fundamental and second harmonic modes. The spatial resolution of the harmonic chirp image is comparable to the spatial resolution of the other modes. SNR improved by 9.8 db for the fundamental and 8.8 db for the harmonic image when changing from pulse to chirp excitation. These figures compare well to an expected increase of 10 db. The CTR was found to be approximately equal for both pulse and chirp excitation. Hydrophone measurements showed that propagation harmonics generation is mainly dependent on peak pressure. Therefore, chirp excitation might be used to decrease contaminating tissue harmonics and hence increase CTR by decreasing the transmitted MI. 1E-4 11:15 a.m. A NEW IMAGING STRATEGY UTILIZING WIDEBAND TRANSIENT RESPONSE OF ULTRASOUND CONTRAST AGENTS D. E. KRUSE* 1,C.K.YEH 2, and K. W. FERRARA 1, 1 University of California, Davis, CA, 2 National Taiwan University, Taipei, Taiwan. Corresponding dekruse@ucdavis.edu High resolution clinical systems operating near 15 MHz are just becoming available; however they lack sensitive harmonic imaging modes for contrast agent detection primarily due to limited bandwidth. When sufficiently driven, it is well known from both experiment and theoretical models that microbubbles produce omnidirectional wideband acoustic transient responses upon collapse. This response has been utilized at frequencies below 7 MHz, but has not been explored at frequencies extending to 15 MHz, where resolution and sensitivity degrade more quickly as a function of depth. To overcome these limitations, we propose a novel strategy utilizing 2 separate transducers at widely separated frequencies 184

4 and arranged confocally for transmit 2 MHz/receive 15 MHz (T2R15) to simultaneously excite and receive acoustic transients. Experiments were performed to demonstrate that T2R15 shows similar resolution and greatly reduced attenuation compared to T15R15, and superior resolution compared to T2R2. In the experiments, T2 consisted of a 2.25 MHz single cycle, rarefaction-first pulse, with peak negative pressure varied from -200 kpa to -1.2 MPa. For comparison, T15 was generated with a wideband excitation and peak negative pressure of -240 kpa to simulate the pressure obtained following 4 cm of an attenuating medium (0.5 db/cm/mhz). To gain perspective, this pressure corresponds to -7.6 MPa without attenuation and neglecting non-linear propagation. To simulate closely spaced vessels, a lipid shelled contrast agent was pumped through two, 200 µm tubes with centers separated by 400 µm with a mean velocity of 2 mm/s. The flow phantom was placed in a water tank at the focus of both transducers, which were separated by 40 and mechanically scanned together. The axial resolution for T2R15 was sufficient to resolve and map Doppler power flow profiles in both vessels, thus illustrating high resolution and bandwidth of T2R15, which would be impossible at T2R2, where λ=770 µm. Acoustic transients were detected for T2 starting near -400 kpa. Results comparing T2R15 bandwidth and echo amplitude as a function of transmitted pressure will be presented. We acknowledge the NIH (EB 00239) for their support. 1E-5 11:30 a.m. TRIPLET PULSE SEQUENCE FOR SUPERIOR MICROBUBBLE/TISSUE CONTRAST S. UMEMURA* 1,T.AZUMA 1, H. KURIBARA 2, and H. KANDA 2, 1 Hitachi Central Research Laboratory, 2 Hitachi Medical Corporation. Corresponding sumemura@crl.hitachi.co.jp A number of imaging sequences have been proposed to improve microbubble/tissue contrast of harmonic imaging, in which the intensityof tissue harmonic echoes, arising from the nonlinear propagation of a transmit pulse in tissue, can be too significant to ignore in comparison with that of harmonic echoes from microbubbles. It is considered that the phase relation between transmit waves and reflected tissue echoes remains constant even after nonlinear propagation in the diagnostic amplitude range. In contrast, microbubble oscillation is so nonlinear that the phase relation between transmit waves and microbubble echoes may vary depending on the transmit amplitude. A new pulse echo sequence is conceived utilizing this difference of nonlinear character for surperior microbubble/tissue contrast. Three-time transmit/receive are performed with transmit pulses with the same envelope and a phase shift by 120, and the received echoes are summed. In the summation, the fundamental and second-harmonic components of tissue echoes will be completely cancelled while those of microbubble echoes will persist. The first order estimation of the microbubble/tissue contrast achievable with the proposed sequence was carried out, based on the numerical simulations of microbubble scattering and nonlinear propagation as responces to 185

5 the same pulse waves at 2 MHz. Scattering by a microbubble in water subjected to an acoustic pulse was calculated by numerically solving the Rayleigh-Plesset equation. Nonlinear propagation of an acoustic pulse in a contiguous tissue with the same attenuation coeffcient and B/A parameter as human liver was calculated using a finite element code, PZFlex. Waveforms after travelling 60 mm were analyzed. The transmit amplitude was adjusted so that it would be reduced to a certain magnitude at the reference point. Both calculated echo waveforms were purified with the same band pass filter, and the output peak-to-peak amplitudes were compared. The result predicted that the new sequence would achieve a microbubble/tissue contrast superior to the conventional B-mode and the pulse inversion sequence by 70 and 40 db, respectively, at a pulse-peak amplitude of 0.1 MPa. The experimental results with a tissue phantom and those with a flow phantom will also be presented. Authors thank to K. Asafusa and T. Osaka for their cooperation in constructing the data acquisition system for the experiment. 1E-6 11:45 a.m. A NEW HIGH FREQUENCY DESTRUCTION/REPERFUSION SYSTEM C. K. YEH* 1, D. E. KRUSE 2, M. C. LIM 3, D. E. REDLINE 3, and K. W. FERRARA 2, 1 National Taiwan University, Taipei, Taiwan, 2 University of California, Davis, CA, 3 UC Davis Medical Center, Sacramento, CA. Corresponding cyeh@ucdavis.edu In order to improve the resolution of contrast-assisted imaging systems, we have created a high frequency destruction/reperfusion imaging system with a spatial resolution of 160 µm x 160 µm. This represents a 25x improvement in resolution compared to previous efforts at clinical frequencies ( 800 µm square), thus allowing a separation of slow capillary and faster arteriole flow velocities. The system utilizes a 1-MHz cylindrically focused transducer for destruction and a 25-MHz spherically focused transducer for pulse/echo imaging. New signal processing methods take advantage of a priori knowledge of contrast echo decorrelation between frames as an alternative to previous methods which use non-linear bubble oscillations to separate bubble and tissue echoes. Speckle tracking and a clutter filter are applied across frames to remove the challenging physiologic motion artifacts that are obtained when imaging with a mechanically scanned transducer. To test the system, a new flow phantom has been developed capable of generating very low flow velocities typically found in the microcirculation ranging from 0.1 to 5 mm/s. Using an exponential reperfusion model, flow constants proportional to absolute flow rate were estimated from B-mode time-intensity curves. The in vitro results indicate a strong correlation (R=0.99) between the actual flow velocity and the estimated rate constant. The time intensity curves for both the in vitro and in vivo data show similar variability over time which is shown to be a function of the region-of-interest (ROI) size over which the intensities are summed. Preliminary in vivo images are presented showing blood perfusion in the ciliary processes and iris of the rabbit 186

6 eye. We estimate the time to 80% intensity for the in vivo data and demonstrate that this time ranges from 0.8 to 6.7 s. ROIs from within the iris include a range of reperfusion times expected for arterioles and capillaries. ROIs from the ciliary processes yielded slower perfusion as expected from vascular casts of the microcirculation in this region. Potential applications of this system include high-resolution perfusion assessment in small animals. We acknowledge the NIH (CA 76062) for their support. Session: 2E ALL YOU WANTED TO KNOW ABOUT IMAGING Chair: T. Thomas Siemens Ultrasound 2E-1 10:30 a.m. (Invited) CODED EXCITATION FOR DIAGNOSTIC ULTRASOUND: A SYSTEM DEVELOPER S PERSPECTIVE R. Y. CHIAO* and X. HAO, GE Medical Systems, Milwaukee, WI. Corresponding Richard.Chiao@med.ge.com Image quality in diagnostic B-mode ultrasound is fundamentally determined by resolution and penetration. Resolution depends on the frequency and bandwidth of the transmitted pulse, while penetration depends on the pulse energy, which in turn depends on the pulse amplitude and duration. Conventionally, high bandwidth for resolution has been achieved by using a short pulse. This results in a tradeoff between resolution and penetration since a short pulse also constrains the pulse energy due to the limited amplitude that may be transmitted for regulatory or hardware reasons. Coded excitation increases the transmitted pulse duration for increased energy while retaining the resolution of a short pulse through appropriate coding on transmit and decoding on receive. Physically, pluse energy is distributed with coding over a long time interval and over a wide bandwidth on transmit that is subsequently compressed to a short time interval on receive to gain SNR without loss of resolution. Coded Excitation has long been used in RADAR, however it has only recently been implemented on commercial ultrasound systems. This paper reviews the basic concepts behind coding and decoding for pulse compression including binary and chirp coding for both fundamental and harmonic imaging; discusses practical implementation issues related to tranducer bandwidth, dynamic focusing, and frame rate; and presents clinical images and a new theoretical result that achieves complete 2nd harmonic compression simultaneous with fundamental cancellation by using quadrature signals. 187

AN ULTRASOUND MODELING TOOL FOR CONTRAST AGENT IMAGING. Kangqiao Zhao, 2010, May

AN ULTRASOUND MODELING TOOL FOR CONTRAST AGENT IMAGING. Kangqiao Zhao, 2010, May AN ULTRASOUND MODELING TOOL FOR CONTRAST AGENT IMAGING -- Introduction ti to BubbleSim Kangqiao Zhao, 2010, May OUTLINE Introduction to Contrast Agent Imaging Applications Detection ti techniques Mechanical

More information

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound Ultrasound Physics History: Ultrasound Ultrasound 1942: Dr. Karl Theodore Dussik transmission ultrasound investigation of the brain 1949-51: Holmes and Howry subject submerged in water tank to achieve

More information

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming Ultrasound Bioinstrumentation Topic 2 (lecture 3) Beamforming Angular Spectrum 2D Fourier transform of aperture Angular spectrum Propagation of Angular Spectrum Propagation as a Linear Spatial Filter Free

More information

Dual-frequency insonation of single microbubbles

Dual-frequency insonation of single microbubbles Dual-frequency insonation of single microbubbles M. Emmer a, H. J. Vos b and N. De Jong c,d a Erasmus MC, Ee22, P.O. Box 24, CA Rotterdam, Netherlands b Biomedical Engineering, Erasmus MC, P.O. Box 24,

More information

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski Abstract The paper presents the multi-element synthetic

More information

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations The Ultrasound Research Interface: A New Tool for Biomedical Investigations Shelby Brunke, Laurent Pelissier, Kris Dickie, Jim Zagzebski, Tim Hall, Thaddeus Wilson Siemens Medical Systems, Issaquah WA

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 4, 6, 2M Open access books available International authors and editors Downloads Our authors are

More information

Lecture #5: Using Nonlinearity: Harmonic and Contrast-enhanced Ultrasound. Lecturer: Paul Sheeran

Lecture #5: Using Nonlinearity: Harmonic and Contrast-enhanced Ultrasound. Lecturer: Paul Sheeran Lecture #5: Using Nonlinearity: Harmonic and Contrast-enhanced Ultrasound Lecturer: Paul Sheeran Lecture Schedule 2 Jan. 7: Ultrasound and bioeffects: safety regulations and limits, ultrasound-mediated

More information

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions. Lesson 06: Pulse-echo Imaging and Display Modes These lessons contain 26 slides plus 15 multiple-choice questions. These lesson were derived from pages 26 through 32 in the textbook: ULTRASOUND IMAGING

More information

APPLYING SYNTHETIC APERTURE, CODED EXCITATION, AND TISSUE HARMONIC IMAGING TECHNIQUES TO ALLOW ULTRASOUND IMAGING WITH A VIRTUAL SOURCE ROBYN T.

APPLYING SYNTHETIC APERTURE, CODED EXCITATION, AND TISSUE HARMONIC IMAGING TECHNIQUES TO ALLOW ULTRASOUND IMAGING WITH A VIRTUAL SOURCE ROBYN T. APPLYING SYNTHETIC APERTURE, CODED EXCITATION, AND TISSUE HARMONIC IMAGING TECHNIQUES TO ALLOW ULTRASOUND IMAGING WITH A VIRTUAL SOURCE BY ROBYN T. UMEKI THESIS Submitted in partial fulfillment of the

More information

Ultrasound physical principles in today s technology

Ultrasound physical principles in today s technology Education Ultrasound physical principles in today s technology Brian Starkoff M.App.Sc.(Med. Ultrasound), AMS Holland Park Brisbane Queensland Australia Correspondence to email starkoff@optusnet.com.au

More information

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl Ultrasound Beamforming and Image Formation Jeremy J. Dahl Overview Ultrasound Concepts Beamforming Image Formation Absorption and TGC Advanced Beamforming Techniques Synthetic Receive Aperture Parallel

More information

Real Time Deconvolution of In-Vivo Ultrasound Images

Real Time Deconvolution of In-Vivo Ultrasound Images Paper presented at the IEEE International Ultrasonics Symposium, Prague, Czech Republic, 3: Real Time Deconvolution of In-Vivo Ultrasound Images Jørgen Arendt Jensen Center for Fast Ultrasound Imaging,

More information

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound. Resolution Enhancement and Frequency Compounding Techniques in Ultrasound. Proposal Type: Innovative Student PI Name: Kunal Vaidya PI Department: Chester F. Carlson Center for Imaging Science Position:

More information

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI ARCHIVES OF ACOUSTICS 33, 4, 573 580 (2008) LABORATORY SETUP FOR SYNTHETIC APERTURE ULTRASOUND IMAGING Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI Institute of Fundamental Technological Research Polish

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION Spatial resolution in ultrasonic imaging is one of many parameters that impact image quality. Therefore, mechanisms to improve system spatial resolution could result in improved

More information

Optimization of Axial Resolution in Ultrasound Elastography

Optimization of Axial Resolution in Ultrasound Elastography Sensors & Transducers 24 by IFSA Publishing, S. L. http://www.sensorsportal.com Optimization of Axial Resolution in Ultrasound Elastography Zhihong Zhang, Haoling Liu, Congyao Zhang, D. C. Liu School of

More information

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13 Basic Ultrasound Physics Kirk Spencer MD Speaker has no disclosures to make Sound Audible range 20Khz Medical ultrasound Megahertz range Advantages of imaging with ultrasound Directed as a beam Tomographic

More information

Pulse Inversion Techniques in Ultrasonic Nonlinear Imaging

Pulse Inversion Techniques in Ultrasonic Nonlinear Imaging R E V I E W A R T I C L E Pulse Inversion in Ultrasonic Nonlinear Imaging Pulse Inversion Techniques in Ultrasonic Nonlinear Imaging Che-Chou Shen*, Yi-Hong Chou 1,2, Pai-Chi Li 3 Pulse inversion (PI)

More information

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010 Parameter Estimation Techniques for Ultrasound Phase Reconstruction Fatemeh Vakhshiteh Sept. 16, 2010 Presentation Outline Motivation Thesis Objectives Background Simulation Quadrature Phase Measurement

More information

3. Ultrasound Imaging(2)

3. Ultrasound Imaging(2) 3. Ultrasound Imaging(2) Lecture 13, 14 Medical Imaging Systems Jae Gwan Kim, Ph.D. jaekim@gist.ac.kr, X 2220 Department of BioMedical Science and Engineering Gwangju Institute of Sciences and Technology

More information

as ~u 8 2:~ ~ ~ ~ ~ .2 ['""""'1 rr.; ~ > C'd ~ 0) ~ ~ C'd ;::J rr.;!:3 ~ ~ 0 O.J CD Q~ ... p- ~.8 1'1\ ~ ~ ::s 0 ~ 0 ::s rr.; rr.;

as ~u 8 2:~ ~ ~ ~ ~ .2 [''1 rr.; ~ > C'd ~ 0) ~ ~ C'd ;::J rr.;!:3 ~ ~ 0 O.J CD Q~ ... p- ~.8 1'1\ ~ ~ ::s 0 ~ 0 ::s rr.; rr.; Coj...j 0 ~ 0 1"""1 rr.; ~~ 0 ~ ~ 0) O.J CD Q~ ~~ rr.; ~ C'd ;::J rr.;!:3 ~ 0) ~ ~ ::s 0 as ~u ;;. 1"""1 ~ ~ roc ~ ~ ~ ~ 0 ::s ~ ~ 0.2 ['""""'1 rr.; ~ > C'd... p- ~.8 1'1\ ~ ~...,,...-! 8 2:~ NTNU Trondheim

More information

Photoacoustic Imaging of Blood Vessels in Tissue

Photoacoustic Imaging of Blood Vessels in Tissue of Blood Vessels in Tissue F.F.M. de Mul (University of Twente, Enschede, the Netherlands) FdM [µm] Imaging methods for hidden structures in turbid media (tissue) OCT/ OPS (C)M TOF / FM NIR green C(M)

More information

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading ECE 476/ECE 501C/CS 513 - Wireless Communication Systems Winter 2005 Lecture 6: Fading Last lecture: Large scale propagation properties of wireless systems - slowly varying properties that depend primarily

More information

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES Paper presented at the 23rd Acoustical Imaging Symposium, Boston, Massachusetts, USA, April 13-16, 1997: COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES Jørgen Arendt Jensen and Peter

More information

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement The Lecture Contains: Sources of Error in Measurement Signal-To-Noise Ratio Analog-to-Digital Conversion of Measurement Data A/D Conversion Digitalization Errors due to A/D Conversion file:///g /optical_measurement/lecture2/2_1.htm[5/7/2012

More information

Acousto-optic imaging of tissue. Steve Morgan

Acousto-optic imaging of tissue. Steve Morgan Acousto-optic imaging of tissue Steve Morgan Electrical Systems and Optics Research Division, University of Nottingham, UK Steve.morgan@nottingham.ac.uk Optical imaging is useful Functional imaging of

More information

Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m.

Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m. Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m. TISSUE HARMONIC IMAGING WITH IMPROVED TEMPORAL RESOLUTION D. J. NAPOLITANO*, C. H. CHOU, G. W. MCLAUGHLIN, T. L.

More information

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust The physics of ultrasound Dr Graeme Taylor Guy s & St Thomas NHS Trust Physics & Instrumentation Modern ultrasound equipment is continually evolving This talk will cover the basics What will be covered?

More information

Excitation of polymer-shelled contrast agents with high-frequency ultrasound

Excitation of polymer-shelled contrast agents with high-frequency ultrasound Excitation of polymer-shelled contrast agents with high-frequency ultrasound Jeffrey A. Ketterling and Jonathan Mamou Riverside Research Institute, Frederic L. Lizzi Center for Biomedical Engineering,

More information

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS T. Stepinski P. Wu Uppsala University Signals and Systems P.O. Box 528, SE- 75 2 Uppsala Sweden ULTRASONIC IMAGING of COPPER MATERIAL USING

More information

Ultrasonic Linear Array Medical Imaging System

Ultrasonic Linear Array Medical Imaging System Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata-700064.

More information

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions. Lesson 02: Sound Wave Production This lesson contains 24 slides plus 11 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 2 through 7 in the textbook: ULTRASOUND

More information

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading ECE 476/ECE 501C/CS 513 - Wireless Communication Systems Winter 2004 Lecture 6: Fading Last lecture: Large scale propagation properties of wireless systems - slowly varying properties that depend primarily

More information

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time Chapter 4 Pulse Echo Imaging Ultrasound imaging systems are based on the principle of pulse echo imaging. These systems require the use of short pulses of ultrasound to create two-dimensional, sectional

More information

12/26/2017. Alberto Ardon M.D.

12/26/2017. Alberto Ardon M.D. Alberto Ardon M.D. 1 Preparatory Work Ultrasound Physics http://www.nysora.com/mobile/regionalanesthesia/foundations-of-us-guided-nerve-blockstechniques/index.1.html Basic Ultrasound Handling https://www.youtube.com/watch?v=q2otukhrruc

More information

Radar-Verfahren und -Signalverarbeitung

Radar-Verfahren und -Signalverarbeitung Radar-Verfahren und -Signalverarbeitung - Lesson 2: RADAR FUNDAMENTALS I Hon.-Prof. Dr.-Ing. Joachim Ender Head of Fraunhoferinstitut für Hochfrequenzphysik and Radartechnik FHR Neuenahrer Str. 20, 53343

More information

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Diagnosis TTE TEE ICE 3D 4D Evaluation of Cardiac Anatomy Hemodynamic

More information

Physics of ultrasound

Physics of ultrasound 1 Physics of ultrasound Basic principles Nature of ultrasound Sound = longitudinal, mechanical wave particles move parallel to direction of travel Audible sound < 20 khz Ultrasound > 20 khz Sound cannot

More information

THE INFLUENCE OF THE TRANSDUCER BANDWIDTH AND DOUBLE PULSE TRANSMISSION ON THE ENCODED IMAGING ULTRASOUND

THE INFLUENCE OF THE TRANSDUCER BANDWIDTH AND DOUBLE PULSE TRANSMISSION ON THE ENCODED IMAGING ULTRASOUND THE INFLUENCE OF THE TRANSDUCER BANDWIDTH AND DOUBLE PULSE TRANSMISSION ON THE ENCODED IMAGING ULTRASOUND IHOR TROTS, ANDRZEJ NOWICKI, MARCIN LEWANDOWSKI, WOJCIECH SECOMSKI, JERZY LITNIEWSKI Institute

More information

A miniature all-optical photoacoustic imaging probe

A miniature all-optical photoacoustic imaging probe A miniature all-optical photoacoustic imaging probe Edward Z. Zhang * and Paul C. Beard Department of Medical Physics and Bioengineering, University College London, Gower Street, London WC1E 6BT, UK http://www.medphys.ucl.ac.uk/research/mle/index.htm

More information

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission:

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission: Data Transmission The successful transmission of data depends upon two factors: The quality of the transmission signal The characteristics of the transmission medium Some type of transmission medium is

More information

Introduction to Ultrasound Physics

Introduction to Ultrasound Physics Introduction to Ultrasound Physics Vassilis Sboros Medical Physics and Cardiovascular Sciences University of Edinburgh Transverse waves Water remains in position Disturbance traverse producing more wave

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Signal Processing in Acoustics Session 1pSPa: Nearfield Acoustical Holography

More information

Medical Imaging (EL582/BE620/GA4426)

Medical Imaging (EL582/BE620/GA4426) Medical Imaging (EL582/BE620/GA4426) Jonathan Mamou, PhD Riverside Research Lizzi Center for Biomedical Engineering New York, NY jmamou@riversideresearch.org On behalf of Prof. Daniel Turnbull Outline

More information

Chapter 2 Channel Equalization

Chapter 2 Channel Equalization Chapter 2 Channel Equalization 2.1 Introduction In wireless communication systems signal experiences distortion due to fading [17]. As signal propagates, it follows multiple paths between transmitter and

More information

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare 2 DOC1292532 Architecture of Quality Imaging Agile Acoustic Architecture E-Series and XDclear

More information

EE 422G - Signals and Systems Laboratory

EE 422G - Signals and Systems Laboratory EE 422G - Signals and Systems Laboratory Lab 5 Filter Applications Kevin D. Donohue Department of Electrical and Computer Engineering University of Kentucky Lexington, KY 40506 February 18, 2014 Objectives:

More information

Detection of Targets in Noise and Pulse Compression Techniques

Detection of Targets in Noise and Pulse Compression Techniques Introduction to Radar Systems Detection of Targets in Noise and Pulse Compression Techniques Radar Course_1.ppt ODonnell 6-18-2 Disclaimer of Endorsement and Liability The video courseware and accompanying

More information

Comprehensive Ultrasound Research Platform

Comprehensive Ultrasound Research Platform Comprehensive Ultrasound Research Platform Functional Requirements List and Performance Specifications Emma Muir Sam Muir Jacob Sandlund David Smith Advisor: Dr. José Sánchez Date: November 9, 2010 Introduction

More information

Coded excitations NINE. 9.1 Temporal coding

Coded excitations NINE. 9.1 Temporal coding CHAPTER NINE Coded excitations One of the major problems of all synthetic aperture imaging techniques is the signal-to-noise ratio. The signal level decreases not only due to the tissue attenuation but

More information

Underground Sonar Using Shear Waves -Resolution improvement Using Pulse Compression and Dynamic Focusing-

Underground Sonar Using Shear Waves -Resolution improvement Using Pulse Compression and Dynamic Focusing- Acoustics 8 Paris Underground Sonar Using Shear Waves -Resolution improvement Using Pulse Compression and Dynamic Focusing- H. Kawasai and T. Sugimoto Toin University of Yoohama, 1614 Kurogane-cho, Aoba-u,

More information

Compound quantitative ultrasonic tomography of long bones using wavelets analysis

Compound quantitative ultrasonic tomography of long bones using wavelets analysis Compound quantitative ultrasonic tomography of long bones using wavelets analysis Philippe Lasaygues To cite this version: Philippe Lasaygues. Compound quantitative ultrasonic tomography of long bones

More information

TRAVELING wave tubes (TWTs) are widely used as amplifiers

TRAVELING wave tubes (TWTs) are widely used as amplifiers IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 32, NO. 3, JUNE 2004 1073 On the Physics of Harmonic Injection in a Traveling Wave Tube John G. Wöhlbier, Member, IEEE, John H. Booske, Senior Member, IEEE, and

More information

White Rose Research Online URL for this paper: Version: Accepted Version

White Rose Research Online URL for this paper:   Version: Accepted Version This is a repository copy of Enhancement of contrast and resolution of B-mode plane wave imaging (PWI) with non-linear filtered delay multiply and sum () beamforming. White Rose Research Online URL for

More information

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading

ECE 476/ECE 501C/CS Wireless Communication Systems Winter Lecture 6: Fading ECE 476/ECE 501C/CS 513 - Wireless Communication Systems Winter 2003 Lecture 6: Fading Last lecture: Large scale propagation properties of wireless systems - slowly varying properties that depend primarily

More information

Lecture 19. Ultrasound Imaging

Lecture 19. Ultrasound Imaging Lecture 19 Ultrasound Imaging Contents 1. Introduction 2. Ultrasound and its generation 3. Wave propagation in the matter 4. Data acquisition (A, B, M and Doppler model) 5. Imaging reconstruction (5 steps)

More information

Mobile Radio Propagation: Small-Scale Fading and Multi-path

Mobile Radio Propagation: Small-Scale Fading and Multi-path Mobile Radio Propagation: Small-Scale Fading and Multi-path 1 EE/TE 4365, UT Dallas 2 Small-scale Fading Small-scale fading, or simply fading describes the rapid fluctuation of the amplitude of a radio

More information

Signal Characteristics

Signal Characteristics Data Transmission The successful transmission of data depends upon two factors:» The quality of the transmission signal» The characteristics of the transmission medium Some type of transmission medium

More information

Designing Non-linear Frequency Modulated Signals For Medical Ultrasound Imaging

Designing Non-linear Frequency Modulated Signals For Medical Ultrasound Imaging Downloaded from orbit.dtu.dk on: Nov 1, 218 Designing Non-linear Frequency Modulated Signals For Medical Ultrasound Imaging Gran, Fredrik; Jensen, Jørgen Arendt Published in: IEEE Ultrasonics Symposium

More information

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Abstract: Speckle interferometry (SI) has become a complete technique over the past couple of years and is widely used in many branches of

More information

Improving spatial resolution and contrast in ultrasound modulated optical tomography

Improving spatial resolution and contrast in ultrasound modulated optical tomography Improving spatial resolution and contrast in ultrasound modulated optical tomography NT Huynh, H Ruan, ML Mather, BR Hayes-Gill, SP Morgan* Electrical Systems and Optics Research Division, Faculty of Engineering,

More information

Transducer product selector

Transducer product selector Transducer product selector Precision Acoustics Ltd (PA) is pleased to offer a wide range of transducers. PA does not have a catalogue of standard transducers; instead each transducer we supply is custom

More information

Optimal Frequency Selection and Analysis Base on Scattering Cross Section for Ultrasound Contrast Second Harmonic Imaging

Optimal Frequency Selection and Analysis Base on Scattering Cross Section for Ultrasound Contrast Second Harmonic Imaging American Journal of Biomedical Engineering 14, 4(): 33-4 DOI:.593/j.ajbe.144. Optimal Frequency Selection and Analysis Base on Scattering Cross Section for Ultrasound Contrast Second Harmonic Imaging Ming-Huang

More information

Modern radio techniques

Modern radio techniques Modern radio techniques for probing the ionosphere Receiver, radar, advanced ionospheric sounder, and related techniques Cesidio Bianchi INGV - Roma Italy Ionospheric properties related to radio waves

More information

WIRELESS COMMUNICATION TECHNOLOGIES (16:332:546) LECTURE 5 SMALL SCALE FADING

WIRELESS COMMUNICATION TECHNOLOGIES (16:332:546) LECTURE 5 SMALL SCALE FADING WIRELESS COMMUNICATION TECHNOLOGIES (16:332:546) LECTURE 5 SMALL SCALE FADING Instructor: Dr. Narayan Mandayam Slides: SabarishVivek Sarathy A QUICK RECAP Why is there poor signal reception in urban clutters?

More information

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life.

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life. Whitepaper Retrospective Transmit Beamformation ACUSON SC2000 Volume Imaging Ultrasound System Chuck Bradley, Ph.D. Siemens Healthcare Sector Ultrasound Business Unit Mountain View, California USA Answers

More information

Photomultiplier Tube

Photomultiplier Tube Nuclear Medicine Uses a device known as a Gamma Camera. Also known as a Scintillation or Anger Camera. Detects the release of gamma rays from Radionuclide. The radionuclide can be injected, inhaled or

More information

MR Advance Techniques. Flow Phenomena. Class II

MR Advance Techniques. Flow Phenomena. Class II MR Advance Techniques Flow Phenomena Class II Flow Phenomena In this class we will explore different phenomenona produced from nuclei that move during the acquisition of data. Flowing nuclei exhibit different

More information

Incoherent Scatter Experiment Parameters

Incoherent Scatter Experiment Parameters Incoherent Scatter Experiment Parameters At a fundamental level, we must select Waveform type Inter-pulse period (IPP) or pulse repetition frequency (PRF) Our choices will be dictated by the desired measurement

More information

768 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 54, no. 4, april 2007

768 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 54, no. 4, april 2007 768 ieee transactions on ultrasonics, ferroelectrics, and frequency control, vol. 54, no. 4, april 2007 Bandwidth and Resolution Enhancement Through Pulse Compression Michael L. Oelze, Member, IEEE Abstract

More information

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA John S. Popovics and Joseph L. Rose Department of Engineering Science and Mechanics The Pennsylvania State University University Park, PA 16802 INTRODUCTION

More information

This is a repository copy of Nonlinear Generation of Harmonic Content within High Intensity Ultrasound Signals using Granular Chains.

This is a repository copy of Nonlinear Generation of Harmonic Content within High Intensity Ultrasound Signals using Granular Chains. This is a repository copy of Nonlinear Generation of Harmonic Content within High Intensity Ultrasound Signals using Granular Chains. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/114/

More information

Ultrasound Physics and Instrumentation, 5e Chapter 7: Level 1 Quiz Answers. 1) Which of the following is stated in the introduction of the chapter?

Ultrasound Physics and Instrumentation, 5e Chapter 7: Level 1 Quiz Answers. 1) Which of the following is stated in the introduction of the chapter? Ultrasound Physics and Instrumentation, 5e Chapter 7: Level 1 Quiz Answers 1) Which of the following is stated in the introduction of the chapter? a) Because of the importance of Doppler, this chapter

More information

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn 3D Optical Motion Analysis of Micro Systems Heinrich Steger, Polytec GmbH, Waldbronn SEMICON Europe 2012 Outline Needs and Challenges of measuring Micro Structure and MEMS Tools and Applications for optical

More information

Broadband Temporal Coherence Results From the June 2003 Panama City Coherence Experiments

Broadband Temporal Coherence Results From the June 2003 Panama City Coherence Experiments Broadband Temporal Coherence Results From the June 2003 Panama City Coherence Experiments H. Chandler*, E. Kennedy*, R. Meredith*, R. Goodman**, S. Stanic* *Code 7184, Naval Research Laboratory Stennis

More information

SMALL LESION DETECTION WITH RESOLUTION ENHANCEMENT COMPRESSION: A METHOD OF CODED EXCITATION/PULSE COMPRESSION PAUL MITCHELL LINDEN THESIS

SMALL LESION DETECTION WITH RESOLUTION ENHANCEMENT COMPRESSION: A METHOD OF CODED EXCITATION/PULSE COMPRESSION PAUL MITCHELL LINDEN THESIS SMALL LESION DETECTION WITH RESOLUTION ENHANCEMENT COMPRESSION: A METHOD OF CODED EXCITATION/PULSE COMPRESSION BY PAUL MITCHELL LINDEN THESIS Submitted in partial fulfillment of the requirements for the

More information

Random excitation by optimized pulse inversion in contrast harmonic imaging

Random excitation by optimized pulse inversion in contrast harmonic imaging Random excitation by optimized pulse inversion in contrast harmonic imaging Sébastien Ménigot, Jean-Marc Girault To cite this version: Sébastien Ménigot, Jean-Marc Girault. Random excitation by optimized

More information

Doppler Ultrasound. Amanda Watson.

Doppler Ultrasound. Amanda Watson. Doppler Ultrasound Amanda Watson amanda.watson1@nhs.net Before we start Why does blood appear black on a B-mode image? B-mode echoes vs. Doppler echoes In B-Mode we are concerned with the position and

More information

Optimal Control by Transmit Frequency in Tissue Harmonic Imaging

Optimal Control by Transmit Frequency in Tissue Harmonic Imaging Optimal Control by Transmit Frequency in Tissue Harmonic Imaging Sébastien Ménigot and Jean-Marc Girault April 6, 1 Ultrasound imaging systems usually wor in open loop. The system control is thus a sine

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62092 First edition 2001-08 Utrasonics Hydrophones Characteristics and calibration in the frequency range from 15 MHz to 40 MHz Ultrasons Hydrophones Caractéristiques et étalonnage

More information

Acoustic Velocity Independent Ultrasonic Flow-Meter

Acoustic Velocity Independent Ultrasonic Flow-Meter flotek.g 2017- Innovative Solutions in Flow Measurement and Control - Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India Acoustic Velocity Independent Ultrasonic Flow-Meter ABSTRACT Shalini

More information

Introduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University

Introduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University Introduction to Medical Engineering (Medical Imaging) Suetens 6 Ultrasound Imaging Ho Kyung Kim Pusan National University Sound Sonic: 20 Hz 20 khz (audible frequency) Subsonic () Ultrasound

More information

Time and Frequency Domain Windowing of LFM Pulses Mark A. Richards

Time and Frequency Domain Windowing of LFM Pulses Mark A. Richards Time and Frequency Domain Mark A. Richards September 29, 26 1 Frequency Domain Windowing of LFM Waveforms in Fundamentals of Radar Signal Processing Section 4.7.1 of [1] discusses the reduction of time

More information

Non-contact Photoacoustic Tomography using holographic full field detection

Non-contact Photoacoustic Tomography using holographic full field detection Non-contact Photoacoustic Tomography using holographic full field detection Jens Horstmann* a, Ralf Brinkmann a,b a Medical Laser Center Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany; b Institute of

More information

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors Derek Puccio, Don Malocha, Nancy Saldanha Department of Electrical and Computer Engineering University of Central Florida

More information

Where DSP meets Measurement Science: A Sound Example. By Andrew Hurrell PhD

Where DSP meets Measurement Science: A Sound Example. By Andrew Hurrell PhD Where DSP meets Measurement Science: A Sound Example By Andrew Hurrell PhD Measuring ultrasound why bother? 6 million ultrasound scans within NHS during 2004-2005 Ultrasound has potential for: Thermal

More information

Antenna Measurements using Modulated Signals

Antenna Measurements using Modulated Signals Antenna Measurements using Modulated Signals Roger Dygert MI Technologies, 1125 Satellite Boulevard, Suite 100 Suwanee, GA 30024-4629 Abstract Antenna test engineers are faced with testing increasingly

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Physical Acoustics Session 4aPA: Nonlinear Acoustics I 4aPA8. Radiation

More information

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids Joanna Brunker 1, *, Paul Beard 1 Supplementary Information 1 Department of Medical Physics and Biomedical Engineering, University

More information

Sonic Distance Sensors

Sonic Distance Sensors Sonic Distance Sensors Introduction - Sound is transmitted through the propagation of pressure in the air. - The speed of sound in the air is normally 331m/sec at 0 o C. - Two of the important characteristics

More information

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions. Lesson 06: Pulse-echo Imaging and Display Modes This lesson contains 22 slides plus 15 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 26 through 32 in

More information

Development of Broadband Radar and Initial Observation

Development of Broadband Radar and Initial Observation Development of Broadband Radar and Initial Observation Tomoo Ushio, Kazushi Monden, Tomoaki Mega, Ken ichi Okamoto and Zen-Ichiro Kawasaki Dept. of Aerospace Engineering Osaka Prefecture University Osaka,

More information

Advanced Detection Strategies for Ultrasound Contrast Agents

Advanced Detection Strategies for Ultrasound Contrast Agents Advanced Detection Strategies for Ultrasound Contrast Agents ISBN 90-9018845-2 2005 by Jerome Borsboom Cover design by Universal Press. All rights reserved. No part of this publication may be reproduced,

More information

A Detailed Examination of Waveforms from Multiple Sensors on a Composite Pressure Vessel (COPV)

A Detailed Examination of Waveforms from Multiple Sensors on a Composite Pressure Vessel (COPV) A Detailed Examination of Waveforms from Multiple Sensors on a Composite Pressure Vessel (COPV) By M. A. Hamstad University of Denver, Department of Mechanical and Materials Engineering Denver, CO USA

More information

Interference & Superposition. Creating Complex Wave Forms

Interference & Superposition. Creating Complex Wave Forms Interference & Superposition Creating Complex Wave Forms Waves & Interference I. Definitions and Types II. Parameters and Equations III. Sound IV. Graphs of Waves V. Interference - superposition - standing

More information

Multipath fading effects on short range indoor RF links. White paper

Multipath fading effects on short range indoor RF links. White paper ALCIOM 5, Parvis Robert Schuman 92370 CHAVILLE - FRANCE Tel/Fax : 01 47 09 30 51 contact@alciom.com www.alciom.com Project : Multipath fading effects on short range indoor RF links DOCUMENT : REFERENCE

More information

Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves

Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves International Journal of Chemical and Biological Engineering 3:4 010 Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves Hirofumi Taki, Takuya Sakamoto,

More information

Improvement of the power response in contrast imaging with transmit frequency optimization

Improvement of the power response in contrast imaging with transmit frequency optimization Improvement of the power response in contrast imaging with transmit frequency optimization Sébastien Ménigot, Anthony Novell, Ayache Bouakaz, Jean-Marc Girault To cite this version: Sébastien Ménigot,

More information

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA Abstract: A novel interferometric scheme for detection of ultrasound is presented.

More information