PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)
|
|
- Lawrence Glenn
- 5 years ago
- Views:
Transcription
1 INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCUDES: Signal conditioner (body base socket)...() MODE NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTI MANUA This manual describes necessary points of caution when you use this product, including installation, connection, hardware setting and basic maintenance procedures. This unit is factory adjusted and calibrated according to the Ordering Information included in the product package. If you don t need to change the pre-adjusted setting, you can skip the sections on hardware setting and calibration in this manual. COMPENT IDENTIFICATI Connection Diagram Front Cover Specifications Body Base Socket OW TO OPEN TE FRT COVER: Position your finger on the hook at the top of front cover and pull. POINTS OF CAUTI POWER INPUT RATING & OPERATIA RANGE ocate the power input rating marked on the product and confirm its operational range as indicated below: V AC rating: V, 66 z, approx. 6VA, and V DC ratings: Rating ±0%, approx. 6W 0V DC rating: 0V DC, approx. 6W GENERA PRECAUTIS Before you remove the unit from its base socket or mount it, turn off the power supply and input signal for safety. ENVIRMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within - to 60 C ( to 0 F) with relative humidity within 0 to 90% R in order to ensure adequate life span and operation. FRT PANE CFIGURATI The shape of base socket may be different for some models. Input Monitor ED P (not used, always ) Input Monitor ED P Front Cover (open) WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
2 INSTAATI Detach the yellow clamps located at the top and bottom of the unit for separate the body from the base socket. DIN RAI MOUNTING Set the base socket so that its DIN rail adaptor is at the bottom. Position the upper hook at the rear side of base socket on the DIN rail and push in the lower. When removing the socket, push down the DIN rail adaptor utilizing a minus screwdriver and pull. WA MOUNTING Refer to EXTERNA DI- MENSIS. Clamp (top & bottom) DIN Rail mm wide Spring oaded DIN Rail Adaptor Shape and size of the base socket are slightly different with various socket types. TERMINA CNECTIS Connect the unit as in the diagram below or refer to the connection diagram on the top of the unit. EXTERNA DIMENSIS unit: mm (inch) CAMP (top & bottom). (.) 0 (.9) DIN RAI mm wide 6 0 (.). (.) dia. MTG OE (.9) deep 0 (.) 0 (.9) 0 (.) M. SCREW 0 (.) () [. (.)] 0 (.9) When mounting, no extra space is needed between units. --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
3 CNECTI DIAGRAM INPUT SENSOR EXCITATI U() V() OUTPUT POWER Input Connection Examples Dry Contact PWR 0kΩ Voltage Pulse PWR -Wire Current Pulse Built-in Excitation 00Ω -WIRE PICK-UP External DC Supply -WIRE PICK-UP DC SUPPY 00Ω Output Connection Examples Open Collector DC Powered Voltage Pulse Power Photo MOSFET Relay AC Powered Relay or OAD Counter Coil Varistor or Spark Quenching Circuit U OAD Relay or Counter Coil Spark Quenching Diode --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
4 FUNCTI & FEATURES Galvanically isolating pulse rate signals. Pulse logic can be converted. For one-shot output, a pulse rise or drop can be selected for synchronization. Pulse width for one-shot output: 0 µsec. 00 msec. Accepting a wide variety of input: 0. 0 V at the input terminals Built-in sensor excitation: 0 ma, 60 ma, ma I/O PUSE OGIC OUTPUT WAVEFORM INPUT WAVEFORM VOTAGE PUSE or -WIRE CURRENT PUSE DRY CTACT Non VOTAGE PUSE OPEN COECTOR or POWER POTO MOSFET REAY Non The pulse width in one-shot means the bold lined section of a pulse waveform. --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
5 ARDWARE SETTING & CAIBRATI Sensitivity Adj. (V) Sensitivity Adj. (V) Input Monitor ED P (not used, always ) Input Monitor ED P O N SW 6 Fixed to the above setting (except No. )** (front cover open) O N SW 6 Set each switch according to the table below. Sensor Excitation Adj. SW FUNCTIS SWITC NO. INPUT CODE SW FUNCTI A B C D SW - with dry contact input (model suffix: A) with -wire current pulse input (model suffix: ) Adjustable range of sensitivity level for V (: 0 0 V, : 0 V) Refer to the section SENSITIVITY ADJUSTMENT. SW- is used for V adjustment. or (required level) Always or according to the adjustment Noise filter Type (: with, : without) or according to the noise level. Refer to the tables below for the max. frequency 6 Noise filter Type (: with, : without) which can pass through the filter. Attenuator for input signal (: with, : without) Input voltage is attenuated to half the original amplitude with this switch. (one-third for the model number suffix code A.) Input pulse sensing method (: DC coupled, : AC coupled) Turn this switch off with a 0 V or greater offset. *Set to with excitation voltage V. **SW- is for V adjustment, SW- for V. * * * INPUT FITER The tables below show the maximum frequency which can pass through the filter when the sensitivity level is set to V. The frequency may change according to the sensitivity level. After turning the filter, check that the P blinks according to the input signal. If it does not, readjust the sensitivity according to the instructions in the following section. Noise Filter Type (SW- = ) DC Coupling (SW- = ) AC Coupling (SW- = ) V p-p (V) MAX. FREQ. (z) V p-p (V) MAX. FREQ. (z) Noise Filter Type (SW-6 = ) DC Coupling (SW- = ) AC Coupling (SW- = ) V p-p (V) MAX. FREQ. (z) V p-p (V) MAX. FREQ. (z) , Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
6 SENSITIVITY ADJUSTMENT You can change the detection level with the sensitivity adj. located behind the front cover. The V determines the pulse rise and the V determines the pulse fall. See the Ordering Information Sheet included in the package for the factory settings. Input Monitor ED (P) (not used, always ) Input Monitor ED (P) ow to Change the Sensitivity A voltmeter of class 0. or better accuracy with pointed probes is required. V V Voltmeter Test oles ) Connect the negative probe of voltmeter to the terminal of base socket. See the figure to the right. ) If you need a noise filter, turn on the SW- or SW-6. ) Connect the positive probe to the test hole No. and turn the V potentiometer until the meter shows desired value.* ) Connect the positive probe to the test hole No. and turn the V potentiometer until the meter shows desired value.* ) Apply input signal and check that input monitor ED (P) blinks according to the input signal.** * For the V (V) sensitivity level less than V, turn off the SW- (SW-). For less than 0 V, turn on the SW- (SW-). The voltage values approx. half the amplitude are recommended for normal use. You had better have a reasonable span between and V in order to prevent noise interference. ** If the ED does not blink correctly, the sensitivity level may be out of the pulse amplitude. Check the offset, amplitude, etc. and go through the adjustment procedure again. SENSOR EXCITATI ADJUSTMENT You can change the sensor excitation voltage with the sensor excitation adj. located behind the front cover. If you need to change it, check that the required current is within the specification. V V Connect to Terminal of the base socket. Volts 0V Sensitivity Adj. (V) Sensitivity Adj. (V) Sensitivity evel VOTAGE PUSE (example) Input Monitor ED (front cover open) t Amplitude Vinp-p INPUT SENSOR EXC. V A Ammeter Voltmeter U() V() OUTPUT POWER ow to Change the Excitation A voltmeter and ammeter of class 0. or better accuracy are required. V V Volts Exc. 0V DRY CTACT (example) Amplitude Vinp-p t The voltage which remains across the terminals with contact ) Connect the voltmeter across the terminal. ) Connect the ammeter to terminal. ) Turn the potentiometer until the meter shows the desired value. Check that the current value indicated on the ammeter is within the allowable limit. If the value is greater than the limit, lower the voltage value or connect a separate power source. Otherwise, the transmitter may fail. VOTAGE (V) Voltage (V) Current (A) 600mW 60 0 CURRENT (ma) --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. 6 /
7 MAINTENANCE Regular calibration procedure is explained below: TROUBESOOTING Refer to the flow chart below. Checking & Maintenance All wires connected according to the connection diagram? Yes No To TERMINA CNECTIS Is the power supply voltage (Terminal ) at the proper level? Is the load connected to sensor excitation within allowance? No Is the P blinking according to the input signal? Check the input connection again and make sure that the input matches descriptions in the ordering information sheet. To ARDWARE SETTING & CAIBRATI, Refer to the sensitivity adjustment. Yes Check that the load resistance meets the described specification. Yes End of Checking IGTNING SURGE PROTECTI M-System offers a series of lightning surge protector for protection against induced lightning surges. Please contact M-System to choose appropriate models. --, Minamitsumori, Nishinari-ku, Osaka -006 JAPAN Phone: (6)669-0 Fax: (6) info@m-system.co.jp EM-0 Rev. P. /
JPQ2 PULSE ACCUMULATOR
INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as
More informationMODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.
MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs
More informationJTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION
INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received
More informationMODEL: JPR2. Plug-in Signal Conditioners M-UNIT
MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter
More informationWJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)
INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationCTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC
INSTRUCTION MANUA CT TRANSMITTER (camp-on current sensor) MODE CTC CTC BEFORE USE... Than you for choosing M-System. Before use, chec the contents of the pacage you received as outined beow. If you have
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationn FRONT PANEL CONFIGURATIONS
INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationMODEL: M5CTC SEN TRONIC AG
MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationNPN TRANSISTOR OUTPUT MODULE
INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as
More informationDISCRETE INPUT MODULE, 16 points
INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationMODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationMODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]
MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on
More informationStatus Indicator LED PWR LINK COL
INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationR7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2
INSTRUCTION MANUAL DC VOLTAGE OUTPUT MODULE, 2 points MODEL R7L-YV2 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationMULTI POWER TRANSDUCER MODEL LSMT4
ISTRUCTIO MAUAL MULTI POWER TRASDUCER MODEL LSMT4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems
More informationMODEL: DAST-20. Telemetering System
MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationDISCONTINUED MODEL Replaced with Model JPS3
Plug-in Signal Condiioners M-UNIT PUSE ADDER (field-programmable) MODE MODE & SUFFIX CODE SEECTI MODE A : Dry conac B :Volage pulse (Specify sensiiviy) C : V pulse (sensiiviy V) D : V/V pulse (sensiiviy
More informationMODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]
Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive
More informationMODEL: 48NDV. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides
More informationSLIM COMPACT SAFETY RELAY
SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationMODEL: 48NDVD. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire
More informationMODEL: LTWT. Power Transducer Series LT-UNIT
Power Transducer Series T-UNIT WATT TRANSDUCER Functions & Features Proides a DC output signa and a puse totaizer signa in proportion to AC actie power Conenient puse unit output (Wh 10 n ) Measuring bidirectiona
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationMODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series
Power Transducer Series MUTI POWER TRASDUCER Functions & Features Measures simutaneousy severa variabes of a heavycurrent power system: current, votage, active, reactive and apparent power, active and
More informationMODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits)
MODE: R-WT Remote I/O R Series AC POWER MODUE ( input circuits). (.) (.) [] OPTIONS ban: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detai, refer to M-System's
More informationUser s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User s Manual Model MS5 Potentiometer Converter (Free Range Type) IM 77J04S05-0E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 80-8750 Japan Phone: +8-422-52-779 Facsimile:
More informationElectro Controls. Input-Output Modules WattsIndustries.co.uk
Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay
More informationSolid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval
Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationSlim compact safety relay
Slim compact safety relay SF RELAYS Slim type Max..9 Max..9 Max.. Max..99 Max.. Max.. mm inch FEATURES Forcibly guide contact structure (EN Class A TÜV recognized) Slim profile (mm inch) Compact size with
More informationMODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series
MODEL: R-WTB Remote I/O R Series AC POWER MODULE ( input circuits, camp-on current sensor type CLSB use). (.) (.) (.) mm (inch) MODEL: R-WTB[][][][] ORDERING INFORMATION Code number: R-WTB[][][][] Specify
More informationPalm-sized, 16-channel Relay Terminals
Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive
More informationInductive Proximity Sensor
Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More information30 AMP POWER RELAY WITH SPACE SAVING DESIGN
VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage
More informationPower supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)
Controller CSM DS_E_3_1 Offers High-speed Input Response of 0.1 ms and Equipped with Built-in imer High-speed response of 0.1 ms. Ideal as a two-input Controller. Lineup includes the -BK with flip-flop
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More informationSlim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type
Slim type safety relays SF RELAYS Slim type RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION S: Slim type Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A Form B 4:
More information8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols
Safety Instruction Before operating this product, please read carefully the safety symbols and definitions described here. This product complies with class I safety specifications. Installation category
More informationR9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)
INSTRUCTION MANUAL MULTI POWER MONITORING UNIT (clamp-on current sensor CC-Link) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined
More informationUser s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES
User s Manual Model MA5 Distributor (Free Range Type) IM 77J04A05-0E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 80-8750 Japan Phone 8-422-52-779 Facsimile 8-422-52-6793 Please
More informationOPERATION MANUAL LDM-1000
OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4
More informationJUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationCONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions
CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationMODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series
Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal
More informationIndoor, outdoor and duct resistance thermometers
Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 1/6 Indoor, outdoor and duct resistance
More informationULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility
More informationUser s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES
User s Manual Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) IM 77J04X11-01E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 Japan Phone: 81-422-52-7179
More informationMODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection
Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of
More informationNo. 139 Jinghai Third Road, BDA, Beijing, China, Office TEL. +86 (10) Website
PONOVO POWER CO., LTD No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 Office TEL. +86 (10) 5908 9666 E-Mail Info@relaytest.com Website www.relaytest.com T1000 Series Universal Tester VERSION: DATE:
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationRelay for control panel of 1c 10A, 2c 5A and 1a 16A
HN (AHN) VDE Relay for control panel of c A, 2c A and a 6A HN RELAYS (AHN) RoHS compliant FEATURES. Slim and compact size % smaller (width and height) than existing model* (with the condition of screw
More informationGround / Jumper Assembly Tester Catalog No. 6714
Ground / Jumper Assembly Tester Catalog No. 6714 WARNINGS 1) Do not use this tester until all instructions have been read and understood. 2) If either of the circuit breakers have tripped, (the on/off
More informationTV-15, 30 AMP (1 Form A) Power Relay
VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off
More informationPower source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator
SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in
More informationMOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals
MOS FET Relay GVM SSR for Switching Analog Signals, with an Insulation Value of. kvac between Input and Output Terminals Switching minute analog signals. Linear voltage and characteristics. Switching AC
More informationDMS-40PC-4/20S 4½ Digit, 4-20mA Input, LED Display Meters
FEATURES Full-size, 0.52" (3.2mm) high, LED digits +7.5-32Vdc model draws 30mA +24V Isolated-power models Dip-switch selectable range, offset, and decimal points Non-interacting, 20-turn, gain (span) and
More informationMODEL: M8PP1. [4] OUTPUT PULSE WIDTH 1: Equal to the input 2: One-shot output (std. pulse width 50 ms) Specify when optional pulse width is required.
MODE: M8PP1 Dual Oupu Super-mini Signal ondiioners Pico-M Series Max. 50 kz for volage pulse inpu PUSE ISOTOR (buil-in exciaion, E) Funcions & Feaures mplifying, waveshaping a pulse rae inpu and providing
More informationMODEL ITMA DC - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT
J K T Bulletin No. ITMAD Drawing No. LP Released / DC INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG USER PROGRAMMABLE INPUT (Thermocouple types J, K, T, & E, or millivolt) MICROPROCESS CTROLLED SIMPLE ADJUSTABLE
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationLabel Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor
Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN
More informationSolid-state Twin Timer
Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time
More informationIsolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated High Level Voltage Output 7B22 FEATURES Unity gain single-channel signal conditioning output module. Interfaces and filters a +10 V input signal and provides an isolated precision output of +10V.
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationIsolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors
More information4-20mA, 0-10V and general process measuring bargraph displays
Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most
More informationIncorporated with red marker. Suitable for high speed production line
PARTICUAR USE SENSORS SERIES Hot Melt Glue Detector Quick, reliable and non-contact detection of hot melt glue EZ- Miniature sensor head Spot type The sensor head can be mounted in a congested and tight
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationEC Declaration of Conformity
EC Declaration of Conformity TABLE OF CONTENTS 1. SAFETY SUMMARY.. 1 2. INTRODUCTION 5 3. SPECIFICATION 7 EN 61326-1: Electrical equipment for measurement, control and laboratory use EMC requirements (1997+A1:
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationT6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224
T and T+ are trade names of Trol Systems Inc. TSI reserves the right to make changes to the information contained in this manual without notice. publication /4A115MAN- rev:1 2001 TSI All rights reserved
More informationTwo outputs: contact and non-contact
SRIS Sensor Controller Multi-functional slim sensor controller DI rail mounting Two outputs: contact and non-contact Connects two sensors -C7W Mountable on 3 mm.378 in DI rail by one-push. It reduces mounting
More informationLedex Drive Electronics and Coil Suppressors
Ledex and Coil Suppressors Ledex Coil Suppressors A voltage is generated by a changing magnetic field in proximity to a current-carrying member. The equation E = -N dø /dt, describes this by saying that
More informationMODEL: 47DV. Digital Panel Meters 47 Series
MODE: 47DV anel Meters 47 Series DC UT DIGITA ANE METER (5½ digit, CD display type) Functions & Features 5 1/2 digit DC input digital panel meter Scaling range -20000 to 100000 1/8 D size Display color
More informationElectronic Thermostat TE-1 Version according to EN
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More information