MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

Size: px
Start display at page:

Download "MODEL: AS4V. Plug-in Signal Conditioners M-UNIT"

Transcription

1 Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in engineering unit values Setpoint adjustments with the front keypad Software lock Adjustable hysteresis (deadband) On-delay timer Hi/Lo trip and energized/de-energized coil independently selectable for each setpoint Enclosed relays Relays can be powered by 00 V AC and 0 V DC High-density mounting on DIN rail Typical Applications Annunciator Various alarm applications [] OUTPUT : points; N.O. or make contact : points; N.C. or break contact : points; SPDT or transfer contact A: points; N.O. or make contact (small load current) A: points; N.C. or break contact (small load current) A: points; SPDT or transfer contact (small load current) [] POWER INPUT AC Power M: 0 0 V AC, 0 0 Hz (Operational voltage range V, Hz) DC Power R: V DC (Operational voltage range V ± %, ripple %p-p max.) P: V DC (Operational voltage range 0 V, ripple %p-p max.) 0 (.) (.0) 0 (.) mm (inch) MODEL: ASV [][] [][] ORDERING INFORMATI Code number: ASV-[][]-[][] Specify a code from below for each [] through []. (e.g. ASV-S-R/Q) Specify the specification for option code /Q (e.g. /C0/S0/SET) [] OPTIS (multiple selections) Standards & Approvals blank: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIS OF OPTI: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating (UL not available) TERMINAL SCREW MATERIAL /S0: Stainless steel (UL not available) EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-0) [] INPUT Current Z: Range 0 0 ma DC (Input resistance 0 Ω) Voltage S: Range - + V DC (Input resistance MΩ min.) S: Range - + V DC (Input resistance MΩ min.) GENERAL SPECIFICATIS Construction: Plug-in Connection: M. screw terminals Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Sampling cycle: 0 msec. User-configurable items: Front key pad ASV SPECIFICATIS ES-0 Rev. Page /

2 Alarm setpoint Display range scaling Power -delay time Alarm -delay time Moving average Hi/Lo trip operation Coil at alarm Hysteresis (deadband) 0 %, 0 % input setting Latching control Others (Refer to the instruction manual) DISPLAY LED: mm (. ) segment, red Number of display digits: digits for display; digits for display Range: - to (decimal point position selectable) PV indication: Input signal in engineering unit Overrange indication: LEDs blinking Power saving mode: Displays turn off if the keys are untouched for a preset time period LEDs: Red lights turn on when coils are energized. (L and L for -point alarm. L, L, L and L for -point alarm.) INPUT SPECIFICATIS DC Current: 0 0 ma DC; shunt resistor attached to input terminals (0. W) Operational range: 0 0 ma DC (with 0 Ω / 0. W) Minimum increment: 0. ma Default setting: 0 ma DC DC Voltage: - + V DC for S; - + V DC for S Operational range: V DC for S; V DC for S Minimum increment: mv for S; 0 mv for S Default setting: - + V DC for S; - + V DC for S OUTPUT SPECIFICATIS Quad Alarm Relay rating: 0 V A (cos ø = ) 0 V 0. A (cos ø = ) 0 V A (resistive load) Maximum switching voltage(note): 0 V AC or V DC Maximum switching power(note): 0 VA or 0 W Minimum load: V ma Mechanical life: cycles Dual Alarm Relay rating: 0 V A (cos ø = ) 0 V A (cos ø = ) 0 V A (resistive load) Maximum switching voltage(note): 0 V AC or V DC Maximum switching power(note): 00 VA or 0 W Minimum load: V ma Mechanical life: cycles Small load current type Relay rating: 0 V A (resistive load) Maximum switching voltage(note): 0 V DC Maximum switching power(note): 0 W (resistive load) Minimum load: V ma Mechanical life: cycles (Note): The value indicate capacity of output relay in equipment. Use within relay rating for EU and UL. Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) L ( ) L ( ) L ( ) L ( ) Input (%) 0 s s 0 s s 0 LL L H HH Trip Operation in Power Failure Output code, A: All relays turn off. Output code, A: All relays turn on. Output code, A: Terminals, turn on. INSTALLATI AC: VA max. DC:. W max. Operating temperature: - to + C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 00 g (. lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0. % of FS + digit) Display accuracy: ±(0. % of FS + digit) Temp. coefficient: ±0.0 %/ C (±0.00 %/ F) Response time: 0. sec. (0 0 % at 0 % setpoint) Line voltage effect: ±0. % over voltage range Insulation resistance: 0 MΩ with 00 V DC Dielectric strength: 000 V minute (input to output to power to ground) ASV SPECIFICATIS ES-0 Rev. Page /

3 STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 00-- EMS EN 00-- Low Voltage Directive EN - Measurement Category II (output) Installation Category II (power) Pollution Degree Input to output to power Basic insulation (00 V) RoHS Directive EN 0 Approval: UL/C-UL general safety requirements (UL -, CAN/CSA-C. No.-) EXTERNAL VIEW Display ALARM No. Display *Monitor LEDs L L L UP-DOWN Keys L No. UP-DOWN Keys *L or L does not turn on for dual output type. Refer to the instruction manual for detailed procedures. DIMENSIS unit: mm (inch) CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) (.0) M. SCREW 0 (.) (.0) [. (.)] 0 (.) When mounting, no extra space is needed between units. ASV SPECIFICATIS ES-0 Rev. Page /

4 TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM) (.) Input shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM n OUTPUT CODE:, A N.O. Relay Output L L L L n OUTPUT CODE:, A N.C. Relay Output INPUT + R * Low Drift Amplifier Digital Computation Circuit L OUTPUT L OUTPUT L OUTPUT L OUTPUT L OUTPUT L OUTPUT L OUTPUT L OUTPUT U(+) V( ) POWER Base Socket *Input shunt resistor attached for current input. n OUTPUT CODE:, A INPUT + R * SPDT Relay Output Low Drift Amplifier L L Digital Computation Circuit N.C. N.O. N.C. N.O. L OUTPUT L OUTPUT Relay Protection AC Powered LOAD DC Powered U LOAD Inductive Load (Coil) Varistor or Spark Quenching Circuit Inductive Load (Coil) Diode, Varistor or CR Circuit U(+) V( ) POWER Base Socket *Input shunt resistor attached for current input. ASV SPECIFICATIS ES-0 Rev. Page /

5 Specifications are subject to change without notice. ASV SPECIFICATIS ES-0 Rev. Page /

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1. MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs

More information

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NDV. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation) Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

[3] MOUNTING DIRECTION

[3] MOUNTING DIRECTION Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced

More information

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: JB2. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller

More information

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: 48NDVD. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire

More information

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration

More information

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2] MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:

More information

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same

More information

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

General Specifications

General Specifications General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type

More information

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5] MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5] Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type

More information

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: TC10EM. Temperature Controller TC10 Series Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III) MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC

More information

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10

More information

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: WL40MW1F. Wireless I/O WL40F Series Wireless I/O WL40F Series WIRELESS GATEWAY (Modbus-RTU Transparent 900MHz Band Wireless Device (child device)) FUTIONS & ATURES This unit Incorporates 900MHz band wireless module. Works as a gateway between

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

General Specifications

General Specifications General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage

More information

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available) MODEL: 7HU- Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication, outdoor enclosure, explosion-proof) Functions & Features Universal input: DC mv, T/C,

More information

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550 UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical

More information

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A PCB Relay Low-profile power relay with maximum switching of 8 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm. RoHS

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

MICRO-CONTROLLER X (48mm 48mm)

MICRO-CONTROLLER X (48mm 48mm) PX series Digital temperature Ctroller DATA SHEET Socket Type With frt dimensis of 48 48mm, this socket type temperature ctroller enables On-Off ctrol, PID ctrol or 8-step ramp/soak functi, using thermocouple,

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

OMRON MK-I / -S RELAY

OMRON MK-I / -S RELAY Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

LOW-PROFILE SURFACE-MOUNT RELAY

LOW-PROFILE SURFACE-MOUNT RELAY TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel

More information

General-purpose Relay

General-purpose Relay General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical

More information

Adjustable Digital Process Instrument MDK480

Adjustable Digital Process Instrument MDK480 Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions

More information

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation) INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays. Miniature Power Relays CSM DS_E_1_1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Relays with AC and DC coils have different colors of operating indicators

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

MODEL: LTWT. Power Transducer Series LT-UNIT

MODEL: LTWT. Power Transducer Series LT-UNIT Power Transducer Series T-UNIT WATT TRANSDUCER Functions & Features Proides a DC output signa and a puse totaizer signa in proportion to AC actie power Conenient puse unit output (Wh 10 n ) Measuring bidirectiona

More information

PID CONTROLLERS LT SERIES

PID CONTROLLERS LT SERIES PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

Classification Enclosure rating Contact form Contact material

Classification Enclosure rating Contact form Contact material PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm.

More information

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40 Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

PART NUMBERING SYSTEM

PART NUMBERING SYSTEM Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable

More information

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

Timers GE1A. GE1A Series ON Delay Timers Single Function

Timers GE1A. GE1A Series ON Delay Timers Single Function Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators

More information

SLIM COMPACT SAFETY RELAY

SLIM COMPACT SAFETY RELAY SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile

More information

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

30 AMP POWER RELAY WITH SPACE SAVING DESIGN VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage

More information