MULTI POWER TRANSDUCER MODEL LSMT4

Size: px
Start display at page:

Download "MULTI POWER TRANSDUCER MODEL LSMT4"

Transcription

1 ISTRUCTIO MAUAL MULTI POWER TRASDUCER MODEL LSMT4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE ICLUDES: Multi Power Transducer... (1) Output label for users... (2) Mounting slider... (2) MODEL O. Confirm that the model number described on the product is exactly what you ordered. ISTRUCTIO MAUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POITS OF CAUTIO COFORMITY WITH EU DIRECTIVES This equipment is suitable for Pollution Degree 2 and Measurement Category II, Installation Category II. Prior to installation, check that the insulation class of this unit satisfies the system requirements. Insulation class of this unit is as follows. Input to output Reinforced insulation (480 V) Output to auxiliary power Reinforced insulation (300 V) Altitude up to 2000 meters. The equipment must be mounted inside a panel. The equipment must be installed such that appropriate clearance and creepage distances are maintained to conform to CE requirements. Failure to observe these requirements may invalidate the CE conformance. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. Install lightning surge protectors for those wires connected to remote locations. GEERAL PRECAUTIO Before you remove or mount the unit, turn off the power supply and the input signal for safety. EVIROMET Indoor use. Do not install the unit where it is directly exposed to rain, water droplets or sunlight. When heavy dust or metal particles are present in the air, install the unit inside proper housing and ventilate it. Do not install the unit where it is subjected to continuous vibration. Do not apply physical impact to the unit. Environmental temperature must be within -10 to +55 C (14 to 131 F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. WIRIG Do not install cables close to noise s (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AD... The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. LIGHTIG SURGE PROTECTIO In order to protect the unit from lightning surges entering through signal and power supply cables, use of appropriate lightning surge protectors are recommended. Please contact M-System. AUXILIARY POWER IPUT RATIGS Power input ratings are specified by the model number suffix code V AC rating: V AC, 50/60 Hz, <20VA V DC rating: V DC, <9W 24V DC rating: 24V±10%, <9W 48V DC rating: 48V±10%, <9W EM-1957 Rev.3 P. 1 / 14

2 COMPOET IDETIFICATIO FROT PAEL COFIGURATIO Output Terminals DATA Display Configuration Jack Power Input Terminals Control Buttons Input Terminals ISTALLATIO WALL MOUTIG Insert the provided slider into upper side of the unit, and pull out the slider on the lower side. Fasten the M4 screw to the hole (4.5 mm dia.) of the slider. (torque 1.4 m) To remove the slider, pull it out while pushing the latch to inside as shown in the figure below. DI RAIL MOUTIG Set the unit so that its DI rail adaptor is at the bottom. Position the upper hook at the rear side of the unit on the DI rail and push in the lower. When removing the unit, push down the DI rail adaptor utilizing a minus screwdriver and pull. DI Rail 35mm wide push push Slider EM-1957 Rev.3 P. 2 / 14

3 TERMIAL COECTIOS Connect the unit as in the diagram below. EXTERAL DIMESIOS unit: mm (inch) 7.2 (.28) 24 M3.5 TERMIAL SCREW (.17) DIA. MTG HOLE TERMIAL COVER 140 (5.52) 126 (4.96) 115 (4.53) 119 (4.69) (DI rail mounting) DI RAIL 35mm wide 75 (2.95) 125 (4.92) 116 (4.57) 6.5 (.26) [3.3 (.13)] 8.6 (.34) 13 M4 TERMIAL SCREW MOUTIG REQUIREMETS unit: mm (inch) 75 (2.95) 4-M4 126 (4.96) 130 (5.12) min. EM-1957 Rev.3 P. 3 / 14

4 WIRIG ISTRUCTIOS SOLDERLESS TERMIAL mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. M3.5 Screw (output) Torqu: 0.6 m Applicable wire size: mm 2 (.2 ) max 3. (.1 ) max M4 Screw (auxiliary power, voltage input and current input) Torqu: 1.4 m Applicable wire size: mm 2 4 (.16) max. 8 max. (.31) 4.3 (.17) dia. TERMIAL COECTIOS ote: In order to improve EMC performance, bond the FE terminal to ground. Caution: FE terminal is OT a protective conductor terminal. TERMIAL ASSIGMET ELECTRICAL COECTIO Output Terminals Power Input Terminals Input Terminals CH1+ CH1 CH10+ CH10 CH11+ CH11 CH12+ CH12 U(+) V( ) FE AALOG OUTPUT AALOG OUTPUT 10 COTACT OUTPUT 1 COTACT OUTPUT 2 POWER JACK COFIGURATOR EM-1957 Rev.3 P. 4 / 14

5 System / Application Terminal System / Application Terminal P1 1S 1L P1 1S 1L P1 P2 P3 1S 1L 3S 3L P1 P2 P3 1S 1L 3S 3L Single phase / 2-wire P1 1S 1L k K l L 3-phase / 3-wire, unbalanced P1 P2 P3 1S 1L 3S 3L k l k l u v u v v u U V k K l L U V V U k l k l P1 P2 P3 1S 1L P1 P2 P3 1S 1L P1 1S 1L P1 1S 1L 3-phase / 3-wire, balanced P1 P2 P3 1S 1L k K l L 3-phase / 4-wire, balanced P1 1S 1L k K l L u v v u u v k l U V k K l L P1 P3 1S 1L 3S 3L P1 P3 1S 1L 3S 3L Single phase / 3-wire P1 P3 1S 1L 3S 3L k K l L k K l L P1 P2 P3 1S 1L 2S 2L 3S 3L u v v u U V V U k l k l 3-phase / 4-wire, unbalanced P1 P2 P3 1S 1L 2S 2L 3S 3L k l k l k l P1 P2 P3 1S 1L 2S 2L 3S 3L u v u v u v U V U V U V k l k l k l EM-1957 Rev.3 P. 5 / 14

6 OPERATIG MODE The measurement display items can be chosen with 4 buttons. Phase voltage, Phase 1 Active power Power factor 1THD Phase voltage, Phase 2 Reactive power Frequency 2THD Phase voltage, Phase 3 Apparent power Power factor, Phase 1 3THD Phase to phase, 1 2 Active power, Phase 1 Power factor, Phase 2 Phase to phase THD, 1 2 Phase to phase, 2 3 Active power, Phase 2 Power factor, Phase 3 Phase to phase THD, 2 3 Phase to phase, 3 1 Active power, Phase 3 Phase to phase THD, 3 1 Current, Line 1 Reactive power, Phase 1 Current THD, Line 1 Current, Line 2 Reactive power, Phase 2 Current THD, Line 2 Current, Line 3 Reactive power, Phase 3 Current THD, Line 3 eutral current Apparent power, Phase 1 eutral current THD Apparent power, Phase 2 Apparent power, Phase 3 CHARACTER SET A B C D E F G H I J M O P Q R S T U V W X Y Z EM-1957 Rev.3 P. 6 / 14

7 SETTIG MODE BUTTO OPERATIO Button Menu/ umeric Input IU / PQS Move between Menu/ Increment/decrement at selected digit Select Menu/ Escape from Menu/ Enter the value Return without entering the value SETTIG MEU/SETTIG GROUP MEU Flow chart Operating Mode Press and hold Incorrect Passcode Incorrect Passcode Enter Passcode Enter the passcode. Passcode range: 0000 to When entered passcode is correct, the unit enters to setting menu. When entered passcode is incorrect, the unit returns to operating mode with error message. Setting Menu DEV.I Version Each time is pressed, the firmware version and the model number are alternately displayed. REBT Reboot O YES Operation Return to Setting Menu Reboot the unit PASS Change passcode The passcode can be changed within 0000 to Factory default is LOOP Loop test By selecting output item of loop test; output selection can be changed. AO1 AO10 PO1 PO2 Output Analog output 1 Analog output 10 Pulse output 1 Pulse output 2 Loop test operation Select the digit in the engineering unit value Increase the value at selected digit Decrease the value at selected digit Select O/OFF with / SETT Setting Group Menu IP To Input Setting Menu EER To Pulse Output Setting Menu AOUT To Analog Output Setting Menu OPT To Option Setting Menu MTE To Maintenance Menu EM-1957 Rev.3 P. 7 / 14

8 IP IPUT SETTIG MEU Flow chart To Setting Group Menu Input Setting Menu SYS System Configuration Operation 1P2W : Single phase/2-wire 1P3W : Single phase/3-wire 3P3B : 3-phase/3-wire balanced 3P3U : 3-phase/3-wire unbalanced 3P4B : 3-phase/4-wire balanced * 1 3P4U : 3-phase/4-wire unbalanced * 1 *1. Available only with LSMT4-2xxx-x CT1 CT rating, primary 1 to A [5A] CT2 CT rating, secondary 1 to 5 A [5A] VT1 VT rating, primary 0.05 to kv [0.11 kv] * 2 VT2 VT rating, secondary 50 to 480 V [110 V] * 2 When this setting is changed, voltage range is automatically set as shown in table below. Setting Others Automatic voltage range Same as the setting value VRG Voltage range 50 to 480 (V) [150 V] FREQ AC frequency Operation U1 : Voltage 1 (*) I1 : Current 1 CO I Low-end cutout, current 0.0 to 99.9 (%) [1.0 %] The current value below ( rated current setting value ) is regarded as 0 A. (*): Factory default setting CO V Low-end cutout, voltage 0.0 to 99.9 (%) [1.0 %] The voltage value below ( rated voltage setting value ) is regarded as 0 V. *2. Set rated voltage for VT according to the table shown below. System Configuration Voltage Single phase/2-wire Voltage between V V 3-phase/3-wire Line-to-line voltage V Single phase/3-wire Voltage between V V 3-phase/4-wire Phase voltage V EM-1957 Rev.3 P. 8 / 14

9 ETER PULSE OUTPUT SETTIG MEU Flow chart To Setting Group Menu Select Output PO1 PO2 Pulse Output Setting Menu CT Energy count type ID PARAMETER EP Active energy, incoming EQ Reactive energy, LAG ES Apparent energy EP Active energy, outgoing EQ Reactive energy, LEAD EQ G Reactive energy, incoming, LAG EQ D Reactive energy, incoming, LEAD EQ G Reactive energy, outgoing, LAG EQ D Reactive energy, outgoing, LEAD EQ P Reactive energy, incoming EQ P Reactive energy, outgoing WEI Pulse weight ID PARAMETER 0.001(*) p kwh/pulse 0.01 p 0.01 kwh/pulse 0.1 p 0.1 kwh/pulse 1.0 p 1.0 kwh/pulse p is determined by n calculated from the formula shown below and the table shown below. n= a primary rated voltage primary rated current 1000 Where a is 1: Single phase/2-wire, 2: Single phase/3-wire, 3: 3-phase, 3: 3-phase/4-wire. n p < n < n < n < n < DUR Pulse width Selectable within 100 to 2000 msec. by 100 msec. steps. [100 msec.] EM-1957 Rev.3 P. 9 / 14

10 AOUT AALOG OUTPUT SETTIG MEU Flow chart To Setting Group Menu Select Output AO1 AO2 AO3 Analog Output Setting Menu IP Assigned measurand Refer to the table, Parameters to be assigned to analog outputs. AO4 AO5 AO6 AO7 AO8 AO9 AO10 SCAL Proportional output Set the parameters for four items shown below. Setting range ISP Input range Refer to Analog output parameters table IZER Input 0 % Refer to Analog output parameters table OSP Output 100 % Refer to Analog output range table OZER Output 0 % Refer to Analog output range table With Proportional output, the input range (Input 0 % to Input range) is converted to output range (Output 0 % to Output 100 %.) After Input range is specified, Input 0 % is automatically assigned. Refer to the table, Parameters to be assigned to analog outputs for the value automatically assigned. LIA Linearization SCAL (*) TBL Set 0 % and 100 % for input and output to convert with Proportional output. Refer to the Proportional output for settings. Set the linearization table to convert with the linearization table. Refer to the linearization table for settings. TBL Linearization table Set input/output of 10 points in the linearization table as shown below. Setting range I0 Input 1st point Refer to the Analog : : output range I9 Input 10th point OUT0 Output 1st point Refer to the Analog : : output range OUT9 Output 10th point ADJ Adjustment By selecting item in the table below, output adjustment is performed in the adjustable range. ZERO SPA Adjustable range to (%) [0.00 %] to (%) [ %] Analog output range Model number Output rating Available setting range LSMT4-xxAx-x 4.00 to (ma) 3.20 to (ma) LSMT4-xx4x-x to (V) to (V) LSMT4-xx5x-x to (V) to (V) LSMT4-xx6x-x to (V) to (V) EM-1957 Rev.3 P. 10 / 14

11 Analog output parameters OE I1 I2 I3 I U12 U23 U31 U1 U2 U3 P P1 P2 P3 Q Q1 Q2 Q3 S S1 S2 S3 PF PF1 PF2 PF3 F ot assigned Current, Line 1 Current, Line 2 Current, Line 3 eutral current Phase to phase, Line 1 2 Phase to phase, Line 2 3 Phase to phase, Line 3 1 Phase voltage, Phase 1 Phase voltage, Phase 2 Phase voltage, Phase 3 Active power Active power, Phase 1 Active power, Phase 2 Active power, Phase 3 Reactive power Reactive power, Phase 1 Reactive power, Phase 2 Reactive power, Phase 3 Apparent power Apparent power, Phase 1 Apparent power, Phase 2 Apparent power, Phase 3 Power factor Power factor, Phase 1 Power factor, Phase 2 Power factor, Phase 3 Frequency Input range -100% -75% -50% -25% 0% 25% 50% 75% 100% 0 CT secondary rating 0 Voltage range P (outgoing) 0 (incoming) P P (LEAD) 0 (LAG) P 0 P 0 (LEAD) 1 (LAG) Available setting range for input range 0.00 to % [0.00 to %] 0.00 to % [0.00 to %] to % [0.00 to %] to % [ to %] 0.00 to % [0.00 to %] to % [ to 50.00%] 0.00 to % [0.00 to %] Auto setting value for input 0 % Sign inversion value of the input range 0.00 Sign inversion value of the input range T Q Reactive power for bidirectional current P (LEAD) (outgoing) 0 (LAG) P P (LEAD) (incoming) 0 (LAG) P to % [ to %] Sign inversion value of the input range When LEAD/LAG range of power rating is set, the unit outputs 0 to 50 % for outgoing and outputs; 50 to 100 % for incoming. T PF Power factor for bidirectional current 0 (LEAD) (outgoing) 1 (LAG) (incoming) 0 (LEAD) 1 (LAG) P to % [ to 50.00%] Sign inversion value of the input range When LEAD/LAG range of power factor is set, the unit outputs 0 to 50 % for outgoing; 50 to 100 % for incoming. Calculation of P (power rating) P (power rating) is automatically determined by rounding to the unit (CT secondary rating 100 (W)) after calculated with following formula by system configuration and secondary rating of CT/VT. It is available not to round with option setting. Power rating = (CT secondary rating) (VT secondary rating) a Calculation example System configuration a Rating Power rating Single phase/2-wire 1 110V/5A 220V/5A 500W 1000W Single phase/3-wire 3-phase/3-wire V/5A 110V/5A 220V/5A 1000W 1000W 2000W 3-phase/4-wire 3 220V/5A 3500W Inversion of output 0 % to 100 % When negative value is set to input range, output is inverted. For example, % is set to input range of reactive power, % is automatically set to input 0 % and then output characteristic is the figure shown below. Output (ma) Input (var) (LAG) (LEAD) EM-1957 Rev.3 P. 11 / 14

12 OUTPUT EXAMPLES Reactive power for bidirectional current Output (ma) Input (var) 1000 (LEAD) (LAG) (LEAD) (LAG) Outgoing Incoming Power factor for bidirectional current Range-100 to 100% Range-50 to 50% Output (ma) Output (ma) (LEAD) (LAG) (LEAD) (LAG) input (LEAD) (LAG) (LEAD) (LAG) Outgoing Incoming Outgoing Incoming input EM-1957 Rev.3 P. 12 / 14

13 OPT OPTIO SETTIG MEU Flow chart Option Setting Menu To Setting Group Menu ALIM Analog limit Select O/OFF of Analog limit. O Limit at -1 % and +101 % OFF (*) o limit (output -5 to +105 %) RPR Power rating round O (*) OFF After power rating is calculated by the formula below, it is rounded to nearest the integral multiple of (secondary rating 100 (W)). Power rating is calculated by the formula below (not rounded) Power rating = VT secondary rating CT secondary rating a System a configuration Single phase/2-wire Single phase/3-wire 3-phase/3-wire 3-phase/4-wire O OFF PF S Power factor sign IEC (*) Active power is incoming: positive, outgoing: negative IEEE Phase direction is LAG: positive, LEAD: negative Q S Reactive power sign IEC (*) SPC The range from power factor 1.0 to -180 is positive, other is negative. When incoming same as IEC. When outgoing, sign reversed. Q C Reactive power calculation VEC (*) SIGM Vector calculation method: Qn= Sn 2 Pn 2 Reactive power meter method: 1 smp Qn= (Uni ni) Ii + (smp/4) smp i=1 (*): Factory default setting S C Apparent power calculation VEC (*) SUM Vector calculation method: S = P 2 + Q 2 Sum calculation: S = S1 + S2 + S3 EM-1957 Rev.3 P. 13 / 14

14 MTE MAITEACE MEU Flow chart Maintenance Menu To Setting Group Menu BKUP Backup setting O YES Return to Maintenance Menu. Backup present settings into internal memory. REST Restore setting O YES Return to Maintenance Menu. Restore settings in the internal memory. CLR.A Initialization O YES Return to Maintenance Menu. Initialize settings with default. EM-1957 Rev.3 P. 14 / 14

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

NPN TRANSISTOR OUTPUT MODULE

NPN TRANSISTOR OUTPUT MODULE INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable) INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

53U MULTI POWER MONITOR OPERATING MANUAL MODEL 53U CONTENTS. (4 digital displays)

53U MULTI POWER MONITOR OPERATING MANUAL MODEL 53U CONTENTS. (4 digital displays) OPERATING MANUAL MULTI POWER MONITOR (4 digital displays) MODEL 53U 53U CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 LIGHTNING SURGE PROTECTION... 2 COMPONENT IDENTIFICATION... 3 INSTALLATION... 4 TERMINAL

More information

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of

More information

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link) INSTRUCTION MANUAL MULTI POWER MONITORING UNIT (clamp-on current sensor CC-Link) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation) INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any

More information

Status Indicator LED PWR LINK COL

Status Indicator LED PWR LINK COL INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you

More information

DISCRETE INPUT MODULE, 16 points

DISCRETE INPUT MODULE, 16 points INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

n FRONT PANEL CONFIGURATIONS

n FRONT PANEL CONFIGURATIONS INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.

More information

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series Power Transducer Series MUTI POWER TRASDUCER Functions & Features Measures simutaneousy severa variabes of a heavycurrent power system: current, votage, active, reactive and apparent power, active and

More information

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface.

These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface. ISTRUCTIO MAUAL IM450-U v3.1 -D3b -D3b-485 EERGY MULTIFUCTIO COUTER AVAILABLE MODELS -D3b: 3-phase energy counter with 7+1 digit display. 1 digital input and two digital pulse output for kwhr and kvarhr.

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

Electronic motor protection relay

Electronic motor protection relay Electroic motor protectio relay Type CET 5 - overview CET 5 - A motor protectio system The CET 5 provides umatched capabilities for the protectio, moitorig ad cotrol of idustrial motors. Suitable for all

More information

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM21 72R Retro-Fit Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class

More information

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM210 Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)

More information

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet ISH Delta Energy / Demand (Multifunction instrument) Data Sheet www.rishabh.co.in Page 1 of 6 Version: D 14 / 03 / 2012 Application: ISH Delta Energy measures important electrical parameters in 3 phase

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Analyzer Type EM210 MID Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

ELECTRICAL MULTIFUNCTION METER

ELECTRICAL MULTIFUNCTION METER ISTRUCTIO MAUAL IM454-U v0.9 EMM-4hp-PF-S ELECTRICAL MULTIFUCTIO METER GEERALITY These digital multimeters allow to monitor all the electrical parameters present on a distribution line. The local display

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary Application: Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwor & replaces the multiple analog panel meters. t measures electrical parameters lie AC current,, frequency,

More information

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+) Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Model PR300 Power and Energy Meter

Model PR300 Power and Energy Meter User s Manual Model PR300 Power and Energy Meter 4th Edition Introduction Thank you for purchasing the PR300 Power and Energy Meter. This manual provides information about the procedure for installing,

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

-EMM-4h. INSTRUCTION MANUAL IM442-U-M v0.6 ELECTRICAL MULTIFUNCTION METER

-EMM-4h. INSTRUCTION MANUAL IM442-U-M v0.6 ELECTRICAL MULTIFUNCTION METER ISTRUCTIO MAUAL IM442-U-M v0.6 EMM-4h ELECTRICAL MULTIFUCTIO METER GEERALITY These digital multimeters allow to monitor all the electrical parameters present on a distribution line. The local display of

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

Contents. Introduction and description Package contents Device identification PM Options... 80

Contents. Introduction and description Package contents Device identification PM Options... 80 Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control User s Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control IM 05D01C02-41E IM 05D01C02-41E 3rd Edition Blank Page Introduction i Thank you for purchasing

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS PREMIER INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006, PRI Ltd. 9600-3003-2 Issue C Information contained within this document is subject to change without notice and does not represent a

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation) Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver

More information

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft Energy Management Power Analyzer ype WM-DI Basic Version Optional dual pulse output Alarms (visual only) V L, An Optional galvanically insulated measuring inputs Product Description ype Selection Range

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

Models UT350/UT320 Digital Indicating Controllers

Models UT350/UT320 Digital Indicating Controllers User s Manual Models UT350/UT320 Digital Indicating Controllers User s Manual IM 05D01D02-41E IM 05D01D02-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UT350/UT320

More information

Digital Multifunction Meter - RISH Integra 2000

Digital Multifunction Meter - RISH Integra 2000 Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU Multifunction network analyzer Q15U2... - Q96U2L - Q96U4... Q15E2... - Q96E2... - MCU - MCUH Programmable transducer MCUU OPERATING MANUAL Ipm0163.8 - Edition 06.09 Langer Messtechnik GmbH Soyerhofstrasse

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter GM3T E GM3T-RS485 E Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V

More information

User s Manual Model PR300 Power and Energy Meter

User s Manual Model PR300 Power and Energy Meter User s Manual Model PR300 Power and Energy Meter Yokogawa Electric Corporation st Edition Model PR300 Power and Energy Meter Contents Introduction...i Notices... ii Checking the Package... iii Checking

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information