MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

Size: px
Start display at page:

Download "MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection"

Transcription

1 Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of current transformers. Up to 8 circuits can be measured. (Common voltage measurement) Current sensors are easy to install in existing systems. Wide input range of 5 to 600 A is availabe. All measured values, counter values, display mode, setting data are stored in the non-volatile memory when power is off. By using SD card, data logging of current and power etc. with calendar is available. 5 (4.9) EXTESIO UIT : With connection AUXILIARY POWER SUPPLY AD4: universal V AC (Operational range V, 50 / 60 Hz) / 0 40 V DC (Operational range V, ripple 0 %p-p max) [] OPTIOS /Q: With options (specify the specification) SPECIFICATIOS OF OPTIO: Q (multiple selections) COATIG (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating EX-FACTORY SETTIG /SET: Preset according to the Ordering Information Sheet (o. ESU-6) 40 (5.5) 80 (.5) mm (inch) MODEL: R9CWTU 00 AD4[] ORDERIG IFORMATIO Code number: R9CWTU-00-AD4[] Specify a code from below for []. (e.g. R9CWTU-00-AD4/Q) Specify the specification for option code /Q (e.g. /C0/SET) COFIGURATIO : Single-phase/-wire, -phase/-wire, single-phase/-wire; 8 circuits COECTIO 0: Terminal block I/O 0: Without RELATED PRODUCTS Discrete I/O Extension Unit (model; R9WTU-ED) Multi power Monitoring Extension Unit (model; R9WTU-EP) PC configurator software (model: PMCFG) Downable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software down site or the users manual for the PC configurator for applicable cable types. Clamp-on current sensor (model: CLSE) The clamp-on current sensors, not included in this product package, must be ordered separately. Required number depends upon the system configuration. SD card A SD card is required to store data in the unit. Use the specified model number of memory card. Available for purchase from M-System. Consult M-System. - Hagiwara Solutions SD6-004GH (S-004GT, S-004GL... discontinued) - Apacer Technology AP-ISD04GIS4B-T (AP-ISD04GIS4B-T... discontinued) GEERAL SPECIFICATIOS Construction: Stand-alone Degree of protection: IP0 Connection Auxiliary power or voltage input: M.5 screw terminals (torque 0.8 m) Current input: M screw terminals (torque 0.5 m) R9CWTU SPECIFICATIOS ES-6 Rev.5 Page /

2 etwork: M screw terminals (torque 0.5 m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, ichifu Co.,ltd Applicable wire size M screw terminal: 0.5 to.65 mm (AWG to 6) M.5 screw terminal:.04 to.6 mm (AWG 6 to 4) Configuration: Single-phase/-wire, single-phase/-wire, - phase/-wire Screw terminal: ickel-plated steel Housing material: Flame-resistant resin (black) Isolation: Sensor core to sensor output or current input or voltage input to CC-Link to auxiliary power to FE Measured variables Voltage: R, S, T, R S, S T, T R Current: R, S, T, Active / reactive / apparent power: R, S, T, Σ Power factor: R, S, T, Σ Frequency Active energy: Incoming Reactive energy: Incoming lag Active / reactive / apparent power intervals (demand) Average (demand) current: R, S, T, Harmonic contents: Σ Voltage: R -, S -, T -, R - S, S - T, T - R Current: R, S, T, Max. and min. values Calendar log (inserting SD card): Voltage, Current, power, electric energy, power factor Operating mode setting: Connection, clamp-on sensor selection Status indicators: Power, SD Card Recommended solderless terminal size - M 6 (.4) max. (.) max mm (inch) Recommended solderless terminal size - M.5 etwork cable: CC-Link cable designated by Mitsubishi Electric Station number: - 64 (rotary switch) Station Type: Remote device Data allocation: Baud rate setting: 56 kbps (default), 65 kbps,.5 Mbps, 5 Mbps, 0 Mbps (rotary switch) Baud rate setting: Rotary switch 56kbps, 65kbps,.5Mbps, 5Mbps, 0Mbps CC-Link LED: Run, RD, SD, ERR IPUT SPECIFICATIOS Frequency: 50 / 60 Hz (45 65 Hz) Voltage Input Rated voltage Between lines: 400 V AC Line-neutral (phase voltage): 0 V (single-phase / -wire and -wire) Input burden: UL / 00 kω / phase Over capacity: 00 % of rating for 0 sec., 0 % continuous Selectable primary voltage range: V Current Input CLSE-R5: 0 5 A AC CLSE-05: 0 50 A AC CLSE-0: 0 00 A AC CLSE-0: 0 00 A AC CLSE-40: A AC CLSE-60: A AC Over capacity: 0 % continous, 500 % for 0 sec. Selectable primary current range: A (Using CLSE- R5 the unit is configurable only with configurator software.) Operational range Current: 0 0 % of the rating Voltage: 0 0 % of the rating Apparent power: 0 % of the rating Active/reactive power: ±0 % of the rating Frequency: Hz Power factor: ± (. ) max. (. ) max mm (inch) CC-Link COMMUICATIO CC-Link: Ver..0 Station Type: Remote device Connector: M screw terminal ISTALLATIO Auxiliary power supply AC: < 9 VA DC: < W Operating temperature: -0 to +55 C (4 to F) Operating humidity: 0 to 90 %RH (non-condensing) Atmosphere: o corrosive gas or heavy dust Mounting: Surface or DI rail Weight: 500 g (. lb) R9CWTU SPECIFICATIOS ES-6 Rev.5 Page /

3 PERFORMACE Accuracy (at 0-5 C or F, Hz) * Add the accuracy of the current sensor for overall values. Voltage: ±0.5 % of the rating * Current: ±0.5 % of the rating * Power: ±0.5 % of the rating * Power factor: ±.5 % Frequency: ±0. % of the rating * Energy: ± % Harmonic contents: ± % of the rating * *. Sensor error margin not included *. The described accuracy levels are ensured at the input % or more for phase current with -phase/-wire unbalanced, for neutral current with -phase/4-wire unbalanced, and neutral current with -phase/-wire. Data update period: Harmonic contents and frequency: sec. Other: 500 msec. Calendar clock: (with battery backup) Accuracy: Monthly deviation minutes at 5 C Back up period: Approx. years at 5 C without power With the power on, no battery drain Battery: Primary lithium battery (non-removable) Insulation resistance: 00 MΩ with 500 V DC Dielectric strength: 000 V minute (current input or voltage input to CC-Link to auxiliary power to FE) EXTERAL VIEW FROT VIEW CC-Link Terminals Terminating Resistor SW C C FE 9 8ch 8 8ch ch 6 ch 5 6ch 4 6ch 5ch 5ch T 8 8ch 8ch 6 ch 5 ch 4 6ch 6ch 5ch 5ch 0 T Term on Terminal Block, Current Input Station Address Setting Rotary SW STATIO SD Card Slot Baud Rate Setting Rotary SW Operating Mode Setting DIP SW (SW) Terminal Block, Voltage Input / Auxiliary Power Supply ch ch ch ch 4 ch 5 ch 6 4ch 4ch 8 P P C ch ch ch 4 ch 5 ch 6 ch 4ch 8 4ch 9 U(+) V(-) FE C PC Configurator Connection Jack Status Indicator / CC-Link LED Terminal Block, Current Input R9CWTU SPECIFICATIOS ES-6 Rev.5 Page /

4 TERMIAL COECTIOS Use the model CLSE clamp sensor for current inputs. The figure below shows only one circuit. At the maximum of eight (8) current sensor inputs are available (ch through 8ch). Grounding is not required for low voltage circuits. System / Application Terminal System / Application Terminal P P Single-phase / -wire Three-phase / -wire balanced L P P u v u v v u U V k K l L L U V V U k K l L P P P Single-phase / -wire P Three-phase / -wire unbalanced L P P k l K L u v v u U V V U u v v u U V V U L COECTIO DIAGRAMS MASTER COECTIO Master Unit TERMIATOR blue white yellow FG Remote Unit FE Remote Unit TERMIATOR FE Be sure to connect the terminating resistor across and at both ends of communication line. When this unit is located at an end, turn the terminating resistor SW O. The Master Unit can be located at not only both ends but also any node of the of communication line. R9CWTU SPECIFICATIOS ES-6 Rev.5 Page 4/

5 TERMIAL ASSIGMETS CC-Link C C FE Current Input 9 8ch 8 8ch ch 6 ch 5 6ch 4 6ch 5ch 5ch T 8 8ch 8ch 6 ch 5 ch 4 6ch 6ch 5ch 5ch 0 T o. ID FUCTIO 4 FE CC-Link ground 5 Shield 6 C Unused C Unused Auxiliary Power Supply, Voltage Input P P U(+) V( ) FE o. ID FUCTIO U(+) Auxiliary power (+) V( ) Auxiliary power ( ) FE Power ground 4 Voltage input 5 P Voltage input P 6 P Voltage input P Voltage input o. ID FUCTIO o. ID FUCTIO 5ch Ch.5, Current input 0 5ch Ch.5, Current input 5ch Ch.5, Current input 5ch Ch.5, Current input 6ch Ch.6, Current input 6ch Ch.6, Current input 4 6ch Ch.6, Current input 6ch Ch.6, Current input 5 ch Ch., Current input 4 ch Ch., Current input 6 ch Ch., Current input 5 ch Ch., Current input 8ch Ch.8, Current input 6 8ch Ch.8, Current input 8 8ch Ch.8, Current input 8ch Ch.8, Current input 9 T Unused 8 T Unused Current Input 0 ch ch ch ch 4 ch 5 ch 6 4ch 4ch 8 C ch ch ch 4 ch 5 ch 6 ch 4ch 8 4ch 9 C o. ID FUCTIO o. ID FUCTIO C Unused 0 C Unused ch Ch., Current input ch Ch., Current input ch Ch., Current input ch Ch., Current input 4 ch Ch., Current input ch Ch., Current input 5 ch Ch., Current input 4 ch Ch., Current input 6 ch Ch., Current input 5 ch Ch., Current input ch Ch., Current input 6 ch Ch., Current input 8 4ch Ch.4, Current input 4ch Ch.4, Current input 9 4ch Ch.4, Current input 8 4ch Ch.4, Current input R9CWTU SPECIFICATIOS ES-6 Rev.5 Page 5/

6 DIMESIOS unit: mm (inch) 6 (.4) 4 M SCREW TERMIAL (.8) dia. MTG HOLE DI RAIL 5 mm wide 40 (5.5) 6 (4.96) 5 (4.5) (DI RAIL MOUT) 5 (.95) 5 (4.9) 80 (.5) 6.5 (.5) [4 (.6)]. (.9) M.5 SCREW TERMIALS MOUTIG REQUIREMETS unit: mm (inch) SIGLE MOUTIG 5 (.95) 4 M4 6 (4.96) Pitch 0 (5.) min. BASIC + EXTESIO UIT 5 (.95) 0.5 (.8) 6 M4 6 (4.96) Pitch (8.8) min. R9CWTU SPECIFICATIOS ES-6 Rev.5 Page 6/

7 SCHEMATIC CIRCUITRY & COECTIO DIAGRAM AUX. POWER SUPPLY VOLTAGE IPUT U AUXILIARY POWER SUPPLY V FE 4 P 5 VOLTAGE P 6 Isolation Comm. Circuit FE C To other CC-Link devices COMMUICATIO C 0 Ch. CURRET Ch. 5 CURRET CURRET IPUT Ch. CURRET 4 4 Control Circuit Ch. 6 CURRET CURRET IPUT Ch. CURRET Ch. CURRET 6 6 Ch. 4 CURRET 8 8 Ch. 8 CURRET 9 8 C 9 T C 0 8 T EXTESIO COECTOR Specifications are subject to change without notice. R9CWTU SPECIFICATIOS ES-6 Rev.5 Page /

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link) INSTRUCTION MANUAL MULTI POWER MONITORING UNIT (clamp-on current sensor CC-Link) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined

More information

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: JB2. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2] MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series Power Transducer Series MUTI POWER TRASDUCER Functions & Features Measures simutaneousy severa variabes of a heavycurrent power system: current, votage, active, reactive and apparent power, active and

More information

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter

More information

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: WL40MW1F. Wireless I/O WL40F Series Wireless I/O WL40F Series WIRELESS GATEWAY (Modbus-RTU Transparent 900MHz Band Wireless Device (child device)) FUTIONS & ATURES This unit Incorporates 900MHz band wireless module. Works as a gateway between

More information

MODEL: DLS. Telemetering System

MODEL: DLS. Telemetering System POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power

More information

MULTI POWER TRANSDUCER MODEL LSMT4

MULTI POWER TRANSDUCER MODEL LSMT4 ISTRUCTIO MAUAL MULTI POWER TRASDUCER MODEL LSMT4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation) Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver

More information

NPN TRANSISTOR OUTPUT MODULE

NPN TRANSISTOR OUTPUT MODULE INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as

More information

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same

More information

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1. MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs

More information

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: TC10EM. Temperature Controller TC10 Series Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete

More information

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series MODEL: R-WTB Remote I/O R Series AC POWER MODULE ( input circuits, camp-on current sensor type CLSB use). (.) (.) (.) mm (inch) MODEL: R-WTB[][][][] ORDERING INFORMATION Code number: R-WTB[][][][] Specify

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits)

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits) MODE: R-WT Remote I/O R Series AC POWER MODUE ( input circuits). (.) (.) [] OPTIONS ban: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detai, refer to M-System's

More information

[3] MOUNTING DIRECTION

[3] MOUNTING DIRECTION Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced

More information

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

DISCRETE INPUT MODULE, 16 points

DISCRETE INPUT MODULE, 16 points INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

Electronic motor protection relay

Electronic motor protection relay Electroic motor protectio relay Type CET 5 - overview CET 5 - A motor protectio system The CET 5 provides umatched capabilities for the protectio, moitorig ad cotrol of idustrial motors. Suitable for all

More information

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III) MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC

More information

Status Indicator LED PWR LINK COL

Status Indicator LED PWR LINK COL INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front

More information

onlinecomponents.com

onlinecomponents.com 9 Transistor Remote Terminal Blocks Ultra-compact CompoBus/S Transistor Terminal Blocks SRT models support both high-speed communications (75 kbps) and longdistance communications (5 m) systems, switch

More information

RISH CON - Hz FREQUENCY TRANSDUCER

RISH CON - Hz FREQUENCY TRANSDUCER RISH CON - Hz FREQUENC TRANSDUCER Data Sheet Trasducer for measurig Frequecy Hz www.rishabh.co.i Page of 5 Versio: D 04 / 0 / Applicatio : The Rish CON - Hz trasducer is used for frequecy measuremet. The

More information

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating

More information

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NDV. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides

More information

INSTRUCTION MANUAL IM411-U v0.3. EMT-4s Series MULTIFUNCTIONAL TRANSDUCER

INSTRUCTION MANUAL IM411-U v0.3. EMT-4s Series MULTIFUNCTIONAL TRANSDUCER ISTRUCTIO MAUAL IM411-U v0.3 Series MULTIFUCTIOAL TRASDUCER IDEX ISTRUCTIO MAUAL... 1 Introduction... 2 Available Models... 2 Options... 2 Block Diagram... 2 Measurement Method... 3 Accuracy... 3 Measured

More information

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: 48NDVD. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire

More information

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: RZMS-U9. PC Recorders RZMS Series s RZMS Series PC RECORDER (universal input, 12 points; isolated) Functions & Features Industrial recorder on PC 12-point universal inputs Channel-to-channel isolation Trigger input and alarm contact output

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable

More information

CompoNet Gateway Unit for CC-Link

CompoNet Gateway Unit for CC-Link CompoNet Gateway Unit for CC-Link Overview of Gateway Unit...2 CompoNet Settings...2 CompoNet Gateway Unit for CC-Link...3 1 CRT1-series Smart Slave Units 1 Overview of Gateway Unit The CompoNet Gateway

More information

MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC

MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC MODEL: RC Remote I/O R Series CC-Link I/O MODULE (CE not available. Option /UL Not selectable) MS: Potentiometer input, points (Option /UL Not selectable) CTE: AC current input, points, Clamp-on current

More information

Remote Sensor Amplifier Terminal

Remote Sensor Amplifier Terminal 9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points

More information

Multi-point Temperature Controller

Multi-point Temperature Controller Multi-point Temperature Controller Controls Up to Eight Zones, Built-in DeviceNet Communications Applications include plastic injection and extrusion machines, and continuous temperature control processes

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

Remote Sensor Amplifier Terminal

Remote Sensor Amplifier Terminal 9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points

More information

53U MULTI POWER MONITOR OPERATING MANUAL MODEL 53U CONTENTS. (4 digital displays)

53U MULTI POWER MONITOR OPERATING MANUAL MODEL 53U CONTENTS. (4 digital displays) OPERATING MANUAL MULTI POWER MONITOR (4 digital displays) MODEL 53U 53U CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 LIGHTNING SURGE PROTECTION... 2 COMPONENT IDENTIFICATION... 3 INSTALLATION... 4 TERMINAL

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

Resistance Temperature Device Conversion Module

Resistance Temperature Device Conversion Module No.SS2-2330-0350 (Rev. 1) SystempaK (Digital/Single Case) Resistance Temperature Device Conversion Module Model J-SRP 90/95 Introduction The Resistance Temperature Device (RTD) Conversion Module (J-SRP)

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

Field Network SRT Series

Field Network SRT Series Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Long-distance detection of up to 6,000 mm supports a wide variety of applications. The Sensor is not

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5] MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

Measuring centers MC7x0 series Multifunction Meter MC740

Measuring centers MC7x0 series Multifunction Meter MC740 Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

General Specifications

General Specifications General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Palm-sized, 16-channel Relay Terminals

Palm-sized, 16-channel Relay Terminals Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive

More information

WARNING Improper operation may result in serious personal injury CAUTION

WARNING Improper operation may result in serious personal injury CAUTION SAFETY PRECAUTIONS Thank you for using our S100 Profibus-DP Communication module Safety PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety precautions

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications.

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications. Rev 2-23-217 Electrical Specifications Maximum Power: 5W Typical Efficiency: 87% Input Voltage Range: 12-277 Vac ± 1% Frequency: Power Factor: Inrush Current: Input Current (Max): 5/6 Hz >.9 @ 8-1% load,

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

800W Single Output Power Supply

800W Single Output Power Supply Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( 0% ~ 05% ) U profile, High power density Constant current limiting High efficiency up

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation) INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any

More information

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of

More information

Encoder - Absolut 2RMHF-SSI

Encoder - Absolut 2RMHF-SSI Absolute Encoder: Ø24 mm Hollow Shaft: Ø3 mm to ¼ Inch Singleturn or Multiturn SSI Interface Binary or Gray Code Preset of Zero Position Choice of Counting Direction IP-Rating: IP64 or IP67 Mechanical

More information