JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

Size: px
Start display at page:

Download "JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)"

Transcription

1 Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver Two inputs (phase A and B) are required for adequate operation of the JRQ. EXCITATI : V : V : V Current Voltage A : 0mA DC :0 0mV DC B : 0mA DC :0 00mV DC C : ma DC :0 V DC D :0 0mA DC :0 0V DC E :0 ma DC :0 V DC F :0 0mA DC : V DC G :0 ma DC W : -0 0V DC Z : Specify current W : - V DC 0 : Specify voltage POWER AC Power DC Power K : V AC S : V DC R : V DC V : V DC P :0V DC ORDERING INFORMATI Specify code number and variables. Use Ordering Information Sheet (No. ESU-). Factory setting (table below) will be used if not otherwise specified. Code number (e.g. JRQ--K) Special output range (For codes Z & 0) Factory Setting Input type Open collector Pulse amplitude ---- Noise filter None Detecting level V * (V excitation) V * (/V excitation) Count mode count / pulse (Phase B by one pulse edge) Input zero count 0 Input span count 000 Alarm setpoint 00% Alarm deadband.00% Alarm mode High alarm Linearization Without *. Detecting voltage in the internal circuit Functions & Features Converts a two-phase forward and reverse rotation pulse signal with 0 degree phase difference into a forward and reverse position signal Built-in excitation Field-selectable input type and range Isolation up to 000V AC High-density mounting Typical Applications Measuring moving distance of a machine with a rotary encoder RELATED PRODUCTS Programming unit (model: PU-x) GENERAL SPECIFICATIS Construction: Plug-in Connection: M. screw terminals Housing material: Flame-resistant resin (black) Isolation: Input to output to alarm output to power Pulse sensing: DC coupled Overrange output: Approx. - % at V Alarm mode: High or Low Alarm setpoint: - % Alarm deadband: 0 0% Reset input: Resets the internal counter value (The transmitter output equivalent to 0 count when the reset input terminals are closed for 00 msec. or longer.) Ouput at input/zero/span count overflow Positive side: Held at the max. of % Negative side: Held at the min. of -% Input monitor LED (PL): Red LED flashes according to the input phase A. Input monitor LED (PL): Red LED flashes according to the input phase B. Excitation adjustment: V DC DIP/rotary switches: For selecting input specifications Detecting level adjustments: Used to adjust the threshold to determine the pulse state. Zero and span adjustments: ±% (front) Linearization: Max. points Modular jack: Connecting the PU-x P. / (.) (.) 0 (.) mm (inch) ES-

2 JRQ Software programming: Programming unit (model: PU-x) used to set the input count range, zero and span, alarm, fine output adj., linearization, etc. & Maximum frequency: 00 khz Maximum count range: - to Excitation: Shortcircuit protection; 0mA max. at shortcircuit Minimum pulse width time requirement:. µsec. for both and OFF Open Collector Input requirements EXCITATI SENSING OFF V Approx. V /.ma 00kΩ 00Ω V Approx. V /.ma 00kΩ 00Ω V Approx. V /.ma 00kΩ 00Ω Detecting level: V (V excitation) * V (/V excitation) * Detecting pulse edge: OFF to Voltage Pulse Waveform: Square or sine Input impedance: 0kΩ minimum Pulse amplitude: 0. 00V p-p Max. voltage between input terminals: 0V Detecting level: 0 V* (factory setting: V) Detecting pulse state: A pulse rise detected when the input voltage goes above the detecting level; a pulse sink detected when it goes below the level. *Detecting voltage in the internal circuit. RS- Line Driver Receiver: Conforms to RS- DC Current: 0 0mA DC Minimum span: ma Zero suppression/elevation: Max.. times span Load resistance: drive V maximum Load Resistance 0mA : 0 (Ω maximum) 0mA : 00 ma : mA : 0 0 ma : mA : 00 0 ma : k DC Voltage: -0 V DC Minimum span: mv Zero suppression/elevation: Max.. times span Load resistance: drive 0mA maximum; ma for negative voltage output; at 0.V Load Resistance 0 0mV : 0k (Ω minimum) 0 00mV : 00k 0 V : V : V : 00 V : V : V : 000 ALARM : Relay contact Rated load: V (cosø=) 0V (resistive load) Electrical life 0 cycles (resistive load) Maximum switching voltage: 0V AC or V DC Maximum switching power:.va or 0W Minimum load: 0mV Mechanical life: 0 cycles (00 cycles/minute) For maximum relay life with inductive loads, external protection is recommended. INSTALLATI Power input AC: Operational voltage range V, Hz, approx. VA DC: Operational voltage range: Rating ±0%, or 0V for 0V rating; ripple 0% p-p max.; approx. W (0mA at V) Operating temperature: - to 0 C ( to 0 F) Operating humidity: 0 to 0% RH (non-condensing) Mounting: Surface or DIN rail Dimensions: W H0 D mm (.".".") Weight: 0 g (0. lbs) PERFORMANCE in percentage of span Accuracy: ±0.% Alarm setpoint accuracy: ±0.% Temp. coefficient: ±0.0%/ C (±0.00%/ F) Response time: 0. seconds (0 0%) Line voltage effect: ±0.% over voltage range Insulation resistance: 00MΩ with 00V DC Dielectric strength: 000V minute (input to output to power) 00V minute (input or output or power to alarm output) 000V minute (circuit to ground) Specifications subject to change without notice. P. / ES-

3 0 0 0 FRT PANEL CFIGURATI & SWITCH SETTING Modular Jack Input Monitor LED PL Input Monitor LED PL Detecting Level Adj. Detecting Level Adj. Pin Pulse Amplitude Selector Sensor Excitation Adj. SW SW SW Input Type Selectors Zero Adj. Span Adj. PULSE AMPLITUDE (rotary switch) (*) Factory setting This setting is invalid for RS- line driver input. For voltage pulse input, select the pulse amplitude (V p-p) among the switch positions 0 through. For open collector, set the switch to. DO NOT SET to or. The power supply to the unit must be turned off when changing the setting. SW PULSE AMPLITUDE MAX. VOLTAGE V p-p 0V 0V p-p 0V 0 V p-p V 0V p-p 0V V p-p V 0. V p-p V * 0. 0.V p-p 0.V (*) Open collector *. Maximum frequency limited to ±0 khz. RANGE CFIGURATI DETECTING LEVEL A specific sensitivity scale is applied according to the pulse amplitude setting. The scaled input voltage is then compared to the preset detecting level. The scaled H level voltage must be higher than the detecting level so that the pulse state is accurately detected. (Refer to the instruction manual for detailed information about adjusting the detecting level.) SW PULSE AMPLITUDE SENSITIVITY SCALE V p-p /0 0V p-p /0 0 V p-p / 0V p-p / V p-p 0. V p-p 0. 0.V p-p 0 Open collector DIP SWITCH SETTING (*) Factory setting Pulse sensing, noise filter and frequency range setting are invalid for RS- line driver input. The power supply to the unit must be turned off when changing the setting. Input Type TYPE SW & SW Open collector (*) OFF OFF OFF Voltage pulse OFF OFF OFF OFF RS- line driver* OFF OFF OFF OFF *. Pulse amplitude, detecting level and noise filter settings are invalid, however, in order to prevent wrong setting, we recommend to set the amplitude to 0 00V p-p (SW = 0), the detecting level to 0V, and no noise filter. Noise Filter High setting is for the input frequency ±0 Hz or lower, while Low setting is for ±00 Hz or lower. EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset.V, Count Range Input type: Voltage Input count: Zero count set to 0, Span count set to 000 (Set 0% and 00% range values with the Programming Unit.) Input amplitude: V p-p Detecting level:.v (Set to the offset value after it is scaled by the sensitivity scale.) Noise filter: None (Choose according to the frequency.) The rotary switch and DIP switch are configured as shown to the right. SW SW SW NOISE FILTER SW- & SW- SW- & SW- High OFF Low (*) OFF None OFF OFF EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset V, Count Range Input type: Voltage Input count: Zero count set to -00, Span count set to 00 (Set 0% and 00% range values with the Programming Unit.) Input amplitude: 0 V p-p Detecting level:.v (Set to the offset value after it is scaled by the sensitivity scale.) Noise filter: None (Choose according to the frequency.) The rotary switch and DIP switch are configured as shown to the right. SW SW P. / SW ES-

4 JRQ OPERATIS FORWARD STOP REVERSE STOP 0mA 0V FORWARD REVERSE ma rev. 0 counts fwd. 00 counts 0V rev. 00 counts 0 fwd. 00 counts RESET OPEN CLOSE SCHEMATIC CIRCUITRY & CNECTI DIAGRAM OPEN COLLECTOR or VOLTAGE PULSE min. 00 msec. Pulse counts are added or subtracted according to the rotary encoder s rotating directions. The counts are added when Phase A leads Phase B by 0 degrees (Forward rotation), and subtracted when Phase A lags behind Phase B by 0 degrees (Reverse rotation). ALARM 0 Ry RESET COM ROTARY ENCODER PWR Reset Input * DETECT. LEVEL Waveform Shaper Waveform Shaper M. M. Digital Computation VS Exc. Supply TYPE Isolation Z S Driver U() V() POWER PU-x MODULAR JACK SERIAL TRANSMISSI LINE Base Socket RS- LINE DRIVER ALARM 0 Ry RESET * Reset Input COM PWR ROTARY ENCODER PU-x RS- Receiver RS- Receiver Excitation Supply MODULAR JACK M. Digital Computation M. VS TYPE SERIAL TRANSMISSI LINE Isolation Z S Driver U() V() POWER Base Socket *Terminals and are internally connected. COM terminals of the rotary encoder and the reset input can be connected to either one. Specifications subject to change without notice. P. / ES-

5 EXTERNAL DIMENSIS & TERMINAL ASSIGNMENT mm (inch) CLAMP (top & bottom). (.) 0 (.) 0 (.) DIN RAIL mm wide. (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.) M. SCREW 0 0 (.) (.) (.) [. (.)] (.) When mounting, no extra space is needed between units. P. / ES-

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1. MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs

More information

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in

More information

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: JB2. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation) INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: 48NDVD. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire

More information

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front

More information

[3] MOUNTING DIRECTION

[3] MOUNTING DIRECTION Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced

More information

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step

More information

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NDV. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides

More information

MODEL: DLS. Telemetering System

MODEL: DLS. Telemetering System POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable) INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same

More information

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5] Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type

More information

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of

More information

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III) MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5] MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

n FRONT PANEL CONFIGURATIONS

n FRONT PANEL CONFIGURATIONS INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.

More information

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2] MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []

More information

General Specifications

General Specifications General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all

More information

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Electro Controls. Input-Output Modules WattsIndustries.co.uk Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Model Number Structure

Model Number Structure Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

OPERATION MANUAL LDM-1000

OPERATION MANUAL LDM-1000 OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4

More information

10A to 40A hockey puck type FEATURES

10A to 40A hockey puck type FEATURES (1A, A, A type) (3A, 4A type) 1A to 4A hockey puck type RELAYS FEATURES 1. Two types of terminal shape: Plugin terminal and Screw terminal (3 A, 4 A is screw terminal types only). Flat type of SSR possible

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility

More information

Distributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher

More information

WHEN A PLC IS TOO MUCH, AND SPACE FOR

WHEN A PLC IS TOO MUCH, AND SPACE FOR WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than

More information

Adjustable Digital Process Instrument MDK480

Adjustable Digital Process Instrument MDK480 Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions

More information

MICRO-CONTROLLER X (48mm 48mm)

MICRO-CONTROLLER X (48mm 48mm) PX series Digital temperature Ctroller DATA SHEET Socket Type With frt dimensis of 48 48mm, this socket type temperature ctroller enables On-Off ctrol, PID ctrol or 8-step ramp/soak functi, using thermocouple,

More information

High capacity SSR, both tab and screw terminals available

High capacity SSR, both tab and screw terminals available (A, 15A, A type) (3A, A type) High capacity SSR, both tab and screw terminals available RELAYS FEATURES 1. Two types of terminal shape: Plug-in terminal and Screw terminal (3 A, A is screw terminal types

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

LOW-PROFILE SURFACE-MOUNT RELAY

LOW-PROFILE SURFACE-MOUNT RELAY TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel

More information

SLIM COMPACT SAFETY RELAY

SLIM COMPACT SAFETY RELAY SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity

More information

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003)) TESTING HIGH INSULATI RELAYS (Conforming to the supplementary insulation class of EN Standards (EN)) TX-D RELAYS.9.9 8...9.9 8.. FEATURES Approved to the supplementary insulation class in the EN standards

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C T Series nalog nd Non-Indicating Type, PID Control, Set y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control

More information

Multi Function Timer with Free power, Compact size W38 H42mm

Multi Function Timer with Free power, Compact size W38 H42mm Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

General Specifications

General Specifications General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max. TESTING LOW-PROFILE SURFACE-MOUNT RELAY RELAYS 5.6. mm inch FEATURES Low-profile: 6 mm.36 inch in height comforming to EIA standards (Tape height: max. 6.5 mm.56 inch ) Tape and reel package is available

More information

Process Calibrator. TechChek 820

Process Calibrator. TechChek 820 Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING

More information

Slim type SSR for 1 A and 2 A control AQ-G RELAYS

Slim type SSR for 1 A and 2 A control AQ-G RELAYS VDE Slim type SSR for 1 A and A control AQ-G RELAYS ORDERING INFORMATION current 1: 1 A : A RoHS compliant voltage : 75 to 6 Vrms 1: Zero-cross (3, V) : Random (3, V) Control voltage 5: to 6 V DC 1: 9.6

More information

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: TC10EM. Temperature Controller TC10 Series Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete

More information