JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
|
|
- Abel Stuart Harvey
- 6 years ago
- Views:
Transcription
1 Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver Two inputs (phase A and B) are required for adequate operation of the JRQ. EXCITATI : V : V : V Current Voltage A : 0mA DC :0 0mV DC B : 0mA DC :0 00mV DC C : ma DC :0 V DC D :0 0mA DC :0 0V DC E :0 ma DC :0 V DC F :0 0mA DC : V DC G :0 ma DC W : -0 0V DC Z : Specify current W : - V DC 0 : Specify voltage POWER AC Power DC Power K : V AC S : V DC R : V DC V : V DC P :0V DC ORDERING INFORMATI Specify code number and variables. Use Ordering Information Sheet (No. ESU-). Factory setting (table below) will be used if not otherwise specified. Code number (e.g. JRQ--K) Special output range (For codes Z & 0) Factory Setting Input type Open collector Pulse amplitude ---- Noise filter None Detecting level V * (V excitation) V * (/V excitation) Count mode count / pulse (Phase B by one pulse edge) Input zero count 0 Input span count 000 Alarm setpoint 00% Alarm deadband.00% Alarm mode High alarm Linearization Without *. Detecting voltage in the internal circuit Functions & Features Converts a two-phase forward and reverse rotation pulse signal with 0 degree phase difference into a forward and reverse position signal Built-in excitation Field-selectable input type and range Isolation up to 000V AC High-density mounting Typical Applications Measuring moving distance of a machine with a rotary encoder RELATED PRODUCTS Programming unit (model: PU-x) GENERAL SPECIFICATIS Construction: Plug-in Connection: M. screw terminals Housing material: Flame-resistant resin (black) Isolation: Input to output to alarm output to power Pulse sensing: DC coupled Overrange output: Approx. - % at V Alarm mode: High or Low Alarm setpoint: - % Alarm deadband: 0 0% Reset input: Resets the internal counter value (The transmitter output equivalent to 0 count when the reset input terminals are closed for 00 msec. or longer.) Ouput at input/zero/span count overflow Positive side: Held at the max. of % Negative side: Held at the min. of -% Input monitor LED (PL): Red LED flashes according to the input phase A. Input monitor LED (PL): Red LED flashes according to the input phase B. Excitation adjustment: V DC DIP/rotary switches: For selecting input specifications Detecting level adjustments: Used to adjust the threshold to determine the pulse state. Zero and span adjustments: ±% (front) Linearization: Max. points Modular jack: Connecting the PU-x P. / (.) (.) 0 (.) mm (inch) ES-
2 JRQ Software programming: Programming unit (model: PU-x) used to set the input count range, zero and span, alarm, fine output adj., linearization, etc. & Maximum frequency: 00 khz Maximum count range: - to Excitation: Shortcircuit protection; 0mA max. at shortcircuit Minimum pulse width time requirement:. µsec. for both and OFF Open Collector Input requirements EXCITATI SENSING OFF V Approx. V /.ma 00kΩ 00Ω V Approx. V /.ma 00kΩ 00Ω V Approx. V /.ma 00kΩ 00Ω Detecting level: V (V excitation) * V (/V excitation) * Detecting pulse edge: OFF to Voltage Pulse Waveform: Square or sine Input impedance: 0kΩ minimum Pulse amplitude: 0. 00V p-p Max. voltage between input terminals: 0V Detecting level: 0 V* (factory setting: V) Detecting pulse state: A pulse rise detected when the input voltage goes above the detecting level; a pulse sink detected when it goes below the level. *Detecting voltage in the internal circuit. RS- Line Driver Receiver: Conforms to RS- DC Current: 0 0mA DC Minimum span: ma Zero suppression/elevation: Max.. times span Load resistance: drive V maximum Load Resistance 0mA : 0 (Ω maximum) 0mA : 00 ma : mA : 0 0 ma : mA : 00 0 ma : k DC Voltage: -0 V DC Minimum span: mv Zero suppression/elevation: Max.. times span Load resistance: drive 0mA maximum; ma for negative voltage output; at 0.V Load Resistance 0 0mV : 0k (Ω minimum) 0 00mV : 00k 0 V : V : V : 00 V : V : V : 000 ALARM : Relay contact Rated load: V (cosø=) 0V (resistive load) Electrical life 0 cycles (resistive load) Maximum switching voltage: 0V AC or V DC Maximum switching power:.va or 0W Minimum load: 0mV Mechanical life: 0 cycles (00 cycles/minute) For maximum relay life with inductive loads, external protection is recommended. INSTALLATI Power input AC: Operational voltage range V, Hz, approx. VA DC: Operational voltage range: Rating ±0%, or 0V for 0V rating; ripple 0% p-p max.; approx. W (0mA at V) Operating temperature: - to 0 C ( to 0 F) Operating humidity: 0 to 0% RH (non-condensing) Mounting: Surface or DIN rail Dimensions: W H0 D mm (.".".") Weight: 0 g (0. lbs) PERFORMANCE in percentage of span Accuracy: ±0.% Alarm setpoint accuracy: ±0.% Temp. coefficient: ±0.0%/ C (±0.00%/ F) Response time: 0. seconds (0 0%) Line voltage effect: ±0.% over voltage range Insulation resistance: 00MΩ with 00V DC Dielectric strength: 000V minute (input to output to power) 00V minute (input or output or power to alarm output) 000V minute (circuit to ground) Specifications subject to change without notice. P. / ES-
3 0 0 0 FRT PANEL CFIGURATI & SWITCH SETTING Modular Jack Input Monitor LED PL Input Monitor LED PL Detecting Level Adj. Detecting Level Adj. Pin Pulse Amplitude Selector Sensor Excitation Adj. SW SW SW Input Type Selectors Zero Adj. Span Adj. PULSE AMPLITUDE (rotary switch) (*) Factory setting This setting is invalid for RS- line driver input. For voltage pulse input, select the pulse amplitude (V p-p) among the switch positions 0 through. For open collector, set the switch to. DO NOT SET to or. The power supply to the unit must be turned off when changing the setting. SW PULSE AMPLITUDE MAX. VOLTAGE V p-p 0V 0V p-p 0V 0 V p-p V 0V p-p 0V V p-p V 0. V p-p V * 0. 0.V p-p 0.V (*) Open collector *. Maximum frequency limited to ±0 khz. RANGE CFIGURATI DETECTING LEVEL A specific sensitivity scale is applied according to the pulse amplitude setting. The scaled input voltage is then compared to the preset detecting level. The scaled H level voltage must be higher than the detecting level so that the pulse state is accurately detected. (Refer to the instruction manual for detailed information about adjusting the detecting level.) SW PULSE AMPLITUDE SENSITIVITY SCALE V p-p /0 0V p-p /0 0 V p-p / 0V p-p / V p-p 0. V p-p 0. 0.V p-p 0 Open collector DIP SWITCH SETTING (*) Factory setting Pulse sensing, noise filter and frequency range setting are invalid for RS- line driver input. The power supply to the unit must be turned off when changing the setting. Input Type TYPE SW & SW Open collector (*) OFF OFF OFF Voltage pulse OFF OFF OFF OFF RS- line driver* OFF OFF OFF OFF *. Pulse amplitude, detecting level and noise filter settings are invalid, however, in order to prevent wrong setting, we recommend to set the amplitude to 0 00V p-p (SW = 0), the detecting level to 0V, and no noise filter. Noise Filter High setting is for the input frequency ±0 Hz or lower, while Low setting is for ±00 Hz or lower. EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset.V, Count Range Input type: Voltage Input count: Zero count set to 0, Span count set to 000 (Set 0% and 00% range values with the Programming Unit.) Input amplitude: V p-p Detecting level:.v (Set to the offset value after it is scaled by the sensitivity scale.) Noise filter: None (Choose according to the frequency.) The rotary switch and DIP switch are configured as shown to the right. SW SW SW NOISE FILTER SW- & SW- SW- & SW- High OFF Low (*) OFF None OFF OFF EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset V, Count Range Input type: Voltage Input count: Zero count set to -00, Span count set to 00 (Set 0% and 00% range values with the Programming Unit.) Input amplitude: 0 V p-p Detecting level:.v (Set to the offset value after it is scaled by the sensitivity scale.) Noise filter: None (Choose according to the frequency.) The rotary switch and DIP switch are configured as shown to the right. SW SW P. / SW ES-
4 JRQ OPERATIS FORWARD STOP REVERSE STOP 0mA 0V FORWARD REVERSE ma rev. 0 counts fwd. 00 counts 0V rev. 00 counts 0 fwd. 00 counts RESET OPEN CLOSE SCHEMATIC CIRCUITRY & CNECTI DIAGRAM OPEN COLLECTOR or VOLTAGE PULSE min. 00 msec. Pulse counts are added or subtracted according to the rotary encoder s rotating directions. The counts are added when Phase A leads Phase B by 0 degrees (Forward rotation), and subtracted when Phase A lags behind Phase B by 0 degrees (Reverse rotation). ALARM 0 Ry RESET COM ROTARY ENCODER PWR Reset Input * DETECT. LEVEL Waveform Shaper Waveform Shaper M. M. Digital Computation VS Exc. Supply TYPE Isolation Z S Driver U() V() POWER PU-x MODULAR JACK SERIAL TRANSMISSI LINE Base Socket RS- LINE DRIVER ALARM 0 Ry RESET * Reset Input COM PWR ROTARY ENCODER PU-x RS- Receiver RS- Receiver Excitation Supply MODULAR JACK M. Digital Computation M. VS TYPE SERIAL TRANSMISSI LINE Isolation Z S Driver U() V() POWER Base Socket *Terminals and are internally connected. COM terminals of the rotary encoder and the reset input can be connected to either one. Specifications subject to change without notice. P. / ES-
5 EXTERNAL DIMENSIS & TERMINAL ASSIGNMENT mm (inch) CLAMP (top & bottom). (.) 0 (.) 0 (.) DIN RAIL mm wide. (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.) M. SCREW 0 0 (.) (.) (.) [. (.)] (.) When mounting, no extra space is needed between units. P. / ES-
MODEL: JPR2. Plug-in Signal Conditioners M-UNIT
MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationMODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.
MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs
More informationMODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationJPQ2 PULSE ACCUMULATOR
INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationMODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series
MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationJTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION
INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationMODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series
Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationMODEL: M1EXT. with Display M1E Series
2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized
More informationPPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)
INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More informationMODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched
More informationMODEL: DAST-20. Telemetering System
MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance
More informationMODEL: 48NDVD. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire
More informationMODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal
Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More informationMODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step
More informationMODEL: 48NDV. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationMODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationWJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)
INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationMODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same
More informationMODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]
Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type
More informationMODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors
Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationMODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection
Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of
More informationMODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)
MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationMODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]
MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationn FRONT PANEL CONFIGURATIONS
INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.
More informationMODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]
MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []
More informationGeneral Specifications
General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all
More informationElectro Controls. Input-Output Modules WattsIndustries.co.uk
Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationMODEL: 27HU 27-UNIT MODEL: 27HU [1][2]
Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication
More informationAdvanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched
EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power
More informationBASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter
Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationDRG-SC Series Signal Conditioners
DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationDVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use
True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution
More informationModel Number Structure
Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported
More informationИ М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz
8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal
More informationSolid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval
Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationOPERATION MANUAL LDM-1000
OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4
More information10A to 40A hockey puck type FEATURES
(1A, A, A type) (3A, 4A type) 1A to 4A hockey puck type RELAYS FEATURES 1. Two types of terminal shape: Plugin terminal and Screw terminal (3 A, 4 A is screw terminal types only). Flat type of SSR possible
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility
More informationDistributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher
More informationWHEN A PLC IS TOO MUCH, AND SPACE FOR
WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More informationMICRO-CONTROLLER X (48mm 48mm)
PX series Digital temperature Ctroller DATA SHEET Socket Type With frt dimensis of 48 48mm, this socket type temperature ctroller enables On-Off ctrol, PID ctrol or 8-step ramp/soak functi, using thermocouple,
More informationHigh capacity SSR, both tab and screw terminals available
(A, 15A, A type) (3A, A type) High capacity SSR, both tab and screw terminals available RELAYS FEATURES 1. Two types of terminal shape: Plug-in terminal and Screw terminal (3 A, A is screw terminal types
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationAnalogue temperature controllers
Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications
More informationLOW-PROFILE SURFACE-MOUNT RELAY
TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel
More informationSLIM COMPACT SAFETY RELAY
SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationEconomical Digital Indicators For Process and Electrical Measurement
Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationCOMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS
COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity
More informationIsolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationHIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))
TESTING HIGH INSULATI RELAYS (Conforming to the supplementary insulation class of EN Standards (EN)) TX-D RELAYS.9.9 8...9.9 8.. FEATURES Approved to the supplementary insulation class in the EN standards
More informationEnergy Management Modular Smart Power Transducer Type SPT-90
Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among
More informationTA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C
T Series nalog nd Non-Indicating Type, PID Control, Set y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control
More informationMulti Function Timer with Free power, Compact size W38 H42mm
Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)
More informationNPN PNP NPN PNP NPN PNP
Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationGeneral Specifications
General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationLOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.
TESTING LOW-PROFILE SURFACE-MOUNT RELAY RELAYS 5.6. mm inch FEATURES Low-profile: 6 mm.36 inch in height comforming to EIA standards (Tape height: max. 6.5 mm.56 inch ) Tape and reel package is available
More informationProcess Calibrator. TechChek 820
Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING
More informationSlim type SSR for 1 A and 2 A control AQ-G RELAYS
VDE Slim type SSR for 1 A and A control AQ-G RELAYS ORDERING INFORMATION current 1: 1 A : A RoHS compliant voltage : 75 to 6 Vrms 1: Zero-cross (3, V) : Random (3, V) Control voltage 5: to 6 V DC 1: 9.6
More informationMODEL: TC10EM. Temperature Controller TC10 Series
Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete
More information