Sultan Flow. Data Sheet. Real Time Flow Measurement for Liquids. A higher level of performance
|
|
- Annabel Byrd
- 5 years ago
- Views:
Transcription
1 higher level of performance Data Sheet Real Time Flow Measurement for Liquids Principle of Operations The measurement system operates by transmitting an acoustic wave signal from its transducer towards the liquid being monitored. The reflected signal or echo is received by the transducer and processed. The time between transmission of the acoustic signal and reception of the echo is measured, and using the speed of sound through air, the distance from the transducer to the liquid level is calculated. Flow through the channel or structure is then calculated from the level measurement and the user entered properties of the channel. The system uses sophisticated software to locate and track the correct echo without being affected by echos from fixed objects or changes in the liquid surface. When the liquid level or surface conditions change, the system follows preselected signal tracking parameters. In the event of a total loss of signal, the system adopts signal recovery routines to relocate the correct liquid level. The system employs automatic gain control to compensate for changes in echo amplitude due to variations in environmental conditions. Continuous current, voltage and relay outputs are provided. These outputs can be programmed for failsafe conditions in the event of a loss of signal or system malfunction. Primary reas of pplications Open Channel Flow Water treatment Sewage treatment Irrigation Industrial waste Power waste Environmental monitoring Special flow requirements for unusual flow channels Certifications CE, TEX, S, (FM, CS pending) Conforms to rittish standards for flow calculations. Features: Optimized frequency selections to suit the application environment Capable of monitoring liquid flow under the most difficult conditions Real time diagnostic display Flexible, multi point or calculated scaling of display and outputs Suits a broad range of flumes, wiers and flow control structures Programmable, resettable totalizer Programmable pulse per flow output Programmable failsafe mode Fast acting temperature compensation GSM/CMD remote setup options/config Wide range of communications: Devicenet, Goshawk, HRT, Modbus, Profibus (Fieldbus & Profibus P pending)
2 Typical pplications Details V-otch Sharp-Crested Weir Parshall Flumes Rectangular Sharp-Crested Weir Trapezoidal Sharp-Crested Weir Khafagi-Venturi Flumes Rectangular Constricted Sharp-Crested Weir Palmer-owles Flumes Waste water channel, with a rectangular flume for flow measurement. Sewerage inlet channel with parshall flume for flow measurement. Irrigation channel, with a rectangular sharp crested weir for flow measurement.
3 160mm (6.3 ) mm (5.5 ) 37.70mm (1.4 ) 10.50mm (0.4 ) Dimensions Dimensions 2 inch Remote Mounting Dimensions Screwtop with integral junction box 6 SI/DI/JIS Multifit Shading Flange 3 inch Remote Remote Transducer Table Model C mm in mm in mm in WRT 20 khz WRT 30 khz mm (8.4 ) 189mm (7.4 ) C 2" SP EXT THD E D 53mm (2.0 ) 82mm (3.2 ) F Multi-fit SI/DI/JIS FLGE DIMESIOS SIZE 6 D (PCD) E (OD) F (Hole Dia.) mm in. mm in. mm in REMOTE ELOSURES - Field Mount WFR234 FROT CK 192mm (7.5 ) 145mm (5.7 ) SIDE 107mm (4.2 ) 160mm (6.3 ) 83mm (3.2 ) 3 x 20mm, 1x16 mm Knock outs 165mm (6.5 ) 190mm (7.5 ) DI Rail or screw mountable 151mm (5.9 ) 166mm (6.5 ) 9.6mm (0.3 ) 69mm (2.7 ) Panel Mount Front 96mm (3.8 ) Side 145mm (5.7 ) 133.5mm (5.25 ) ack 89.5mm (3.52 ) Cut-out Size 90 mm (3.54 ) 89.5mm (3.52 ) 89.5mm (3.52 ) 96mm (3.8 ) Cut-out Size 90 mm (3.54 )
4 dvanced Communications GSM/CDM HawkLink GSM/CDM communication device allows any authorized computer with a standard modem and Goshawk software to dial in and calibrate, test or check in on the performance of the Hawk product. Remote technical support and complete commissioning of equipment in applications via our GSM/CDM module allows monitoring and adjustments of settings no matter what corner of the world.
5 LUE LCK SHIELD LCK LUE Test in Wiring Diagrams WFR234 Transducer Connection/Extension RELY 1 RELY 2 RELY 3 RELY 4 RELY 5 WFR234 Transmitter 4-20 m Connection RELY 1 RELY 2 RELY 3 RELY 4 RELY 5 Re-connect Cable Shield to lack JUTIO OX TRSDUCER MS Cable Shield DC-I Extension cable C-I ll cable shields connect to LCK WIRE at transmitter end TRSDUCER LCK LUE Modulating from PLC input Test in MS Driving from Sultan to user PLC DC-I C-I VC Separate lack from Shield USE OLY ELDE 3084 DEKORO IED to extend transducer cable TRSDUCER WFR234 Panel Mount Transmitter SULT 234 REMOTE TRSMITTER RELY 1 RELY 2 RELY 3 RELY 4 RELY 5 LOG TRSDUCER MS DC-I C-I - - LK LU WHT Test 12-30VDC VC OTTOM TOP HawkLink GSM/CDM Connection Flow Transmitter RELY 1 RELY 2 RELY 3 RELY 4 RELY 5 RELY 1 GSM/CDM unit RELY 2 TRSDUCER RELY 3 MS RELY 4 DC-I RELY 5 C-I TRSDUCER LCK LUE MS Test in DC-I C-I LCK LUE Test in Shield to other } W Units GSM LED LED OFF: Modem is in Download mode or switched off. LED permanently O: Modem switched O but not registered to network or no SIM CRD. LED slow flash: Modem switched O and registered to network. LED quick flash: Modem switched O, registered to network & communication in progress.
6 Part umbering Sultan W Flow Remote Electronics Model WFR234 Remote Open Channel Flow Transmitter Housing S Standard polycarbonate electronics housing P Panel Mount Housing Power Supply 24 VDC standard C 48 VDC U Universal C power supply ( VC input) or 24 VDC Output Configuration (PC comms Goshawk standard) S Switch only. 5 relays X analogue output module, includes Modbus comms I HRT olated 4 wire W Modbus Comms only P Profibus DP E Ethernet D Devicenet Z Special Request Internal HawkLink Modem (not available with TEX 0/20 approval) G2 GSM Frequency 800/1900 MHz/19200 aud for US, Canada, rgentina, Chile G4 GSM Frequency 900/1800 MHz/19200 aud for ustralia, Europe, Chile pproval Standard Position Unit / Crane Master Options for Sultan 234 Only X ot required WFR234 S X G4 X X
7 Part umbering Sultan W Remote Transducer Model WRT coustic Wave Remote Transducer Transducer Frequency 50 50kHz for applications up to 5m, available in 2 only 40 40kHz for applications up to 7m, available in 2 only 30 30kHz for applications up to 11m for 2 and 15m for 3 (4 flange and cone is recommended for 3 units) 20 20kHz for applications up to 20m, available in 3 only (4 flange and cone is recommended) Process Temperature - Facing material selection T Standard Temperature Wet tmosphere,(teflon face) Transducer Housing Material 4 Polypropylene, standard for 3, not available for 2 6 Tefzel, standard for 2. Thread Standards (Shading Flange Mount, for 3 sensors) T SP (required for 2 50, 40, 30 khz sensors) Mounting Thread Sizes (Shading Flange Mount, for 3 sensors) 20 2 thread (required for 2 50, 40, 30 khz sensors) pproval Standard 0 Intrinsic Safe: IECEx Zone 0 (Ex ia II T4)/TEX (GrpII Cat1 GD IP67 EEx ia II T4) 1 TEX Encapsulated (Grp II Cat 2 GD EEx m II IP68) 20 TEX Dust (Grp II Cat 1 D T85C IP67) 21 TEX Dust (Grp II Cat 2 D T85C IP67) 22 TEX Dust (Grp II Cat 3 D T85C IP67) Connection C IP68 Sealed unit with cable Cable Length 6 6m cable (Standard) 15 15m cable 30 30m cable 50 50m cable Mounting ccessories Position Unit /Crane Master/Software Options F Flow - Including multifit shading flange and fast temp compensation WRT 30 T 4 X X X C 6 X F Cones for 20 and 30 khz Transducers C04-4 Focalizer Cone, 4 for 20 and 30kHz C02-4 Focalizer Cone option, 4 for 30, 40 and 50 khz 2 sensors
8 Specifications Frequency 20kHz, 30kHz, 40kHz, 50kHz Transducer/mplifier Separation up to 1000m (3281ft) using appropriate RS485 cable Operating Voltage 12-30Vdc (residual ripple no greater than 100mV) Vac 50/60Hz 48Vdc,48Vac-90Vac 50/60Hz Power Consumption 24Vdc 240Vac 48Vdc, 48Vac 90Vac. Cable 4 conductor shielded twisted pair instrument cable. Conductor size dependent on cable length. ELDE 3084, DEKORO or equivalent. Max: ELDE 3084 = 500m (1640 ft) Max: DEKORO IED = 350m (980 ft) Maximum Operating Pressure /- 7.5 PSI (/- 0.5 ar) IMPORTT USE SPECIFIED CLE OLY nalog Output 4-20m (750 24Vdc User supply, 250 ohms internally driven) Communications Goshawk, HRT, Modbus, Profibus DP, Deviceet (Foundation Fieldbus & Profibus P pending) Muliti Drop mode can address units over 4 wire Relay Outputs: (5) Form C (SPDT) contacts, rated 0.5 at 240Vac non-inductive. ll relays have independently adjustable dead bands. Remote failsafe test facility for one relay. lanking Distance 50kHz = 0.25 m (10 ) 40kHz = 0.30 m (12 ) 30kHz = 0.35 m (14 ) 20kHz = 0.45 m (17 ) Maximum Range 5 m (16ft) 50kHz liquids 7 m (22ft) 40kHz liquids 10 m (33ft) 30kHz liquids 20 m (65ft) 20kHz liquids Resolution 1 mm (0.04 ) 50, 40, 30,20 khz Electronic ccuracy /- 0.25% of maximum range Operating Temperature Remote electronics -40 C (-40 F) to 80 C (176 F) Remote transducer -40 C (-40 F) to 80 C (176 F) eam ngle 7.5 without focaliser 50kHz/40kHz/30kHz 4 with focaliser 50kHz/40kHz 6 with focaliser 30kHz/20kHz Display 2 line x 12 character alphanumeric LCD LED ack-lit display Memory on-volatile (o backup battery required) >10 years data retention Enclosure Sealing Remote Electronics IP65 (ema 4x) Remote Transducer IP68 Cable Entries Remote: 3 x 20mm, 1 x 16mm knock outs. Mounting 6 Multifit SI/DI/JIS Flange Typical Weight Sultan W System with appropriate flange and cone Frequency (in khz) kg lb 20/30 20 or 30kHz (3 ) Transducer /40/50 30 (2 ), 40 or 50kHz Transducer Configuration kg lb R6 Remote system with 6m cable R15 Remote system with 15m cable R30 Remote system with 30m cable R50 Remote system with 50m cable dditional product warranty and application guarantees upon request. ll company or product names are registered trademarks or trademarks of their respective owners. Technical data subject to change without notice. Contact Hawk Measurement Systems (Head Office) Maurice Court unawading VIC 3131 ustralia Phone: Fax: info@hawk.com.au Hawk Measurement 3911 W. Van urren STE -7 Phoenix, rizona US Phone HWKLEVEL ( ) Fax: info@hawkmeasure.com 8 Global representatives on Represented by: Rev 1.1, Feb 2008
Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationSultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationSultan Radar. Data Sheet. Typical Uses: Typical Features: The New Dimension Radar System. A higher level of performance
higher level of performance Sultan Radar Data Sheet The ew Dimension Radar System The Sultan based Radar System is a high power, high sensitivity narrow beam system which gives excellent performance in
More informationSultan Acoustic Wave Series
Overview Higher Level of Performance Data Sheet Sultan coustic Wave Series Level, Flow, Positioning, Collision Protection For more information, please visit > www.hawkmeasure.com Overview Principle of
More informationSultan Liquid- Acoustic Wave Technology
A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered
More informationSultan 2 - Acoustic Wave Technology
A higher level of performance Sultan 2 - Acoustic Wave Technology 2 Wire Solids / Liquids level measurements to 60m (196ft) Data Sheet Principle of Operations The SULTAN 2 emits a high powered acoustic
More informationSultan Acoustic Wave Series
A Higher Level of Performance Data Sheet Sultan Acoustic Wave Series Machinery Positioning Systems For more information, please visit > www.hawkmeasure.com Principle of Operation The Sultan for Machinery
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Sultan Sonar Level System System Principle
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Principle of Operation The ORCA Sonar
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationGladiator. Gen 3 Doppler Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Product Flow Detection Circular Polarisation
Overview Higher Level of Performance Data Sheet Gladiator Gen Doppler Microwave Switch Series Product Flow Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com Overview
More informationData Sheet. Acoustic Wave Series. A higher level of performance. Features:
A higher level of performance Data Sheet Acoustic Wave Series - Level, Flow, Positioning, Collision Protection - Principle of Operations The SULTAN 234 emits a high powered acoustic wave transmit pulse
More informationGladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation
Gladiator Microwave Series A Higher Level of Performance Data Sheet Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationSULTAN 234 Series. Acoustic Wave Level Transmitter SULTAN 234 Series Smart Universal Level Transmitter & Network
SULTAN 234 Series Solids / Liquids Level to 60 metres Universal Supply: 2 Wire Loop Powered. 3 Wire DC. 4 Wire AC/DC. Universal Transducer Inputs: 50kHz, 40kHz, 30kHz, 20kHz, 15kHz, 10kHz, 5kHz. GSM/CDMA
More informationINSTRUCTION MANUAL SULTAN FLOW. Acoustic Wave Technology DRAFT. A higher level of performance
INSTRUCTION SULTAN FLOW Acoustic Wave Technology DRAFT A higher level of performance INTRODUCTION CONTENTS PROPRIETARY NOTICE The information contained in this publication is derived in part from proprietary
More informationGladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
Higher Level of Performance Data Sheet Gladiator G1 Series Microwave Waveguide Information eam lockage Detection For more information, please visit > www.hawkmeasure.com G1R or G1S Waveguide oncept M-WG01
More informationGladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
Higher Level of Performance Data Sheet Gladiator G Series Microwave Waveguide Information eam lockage Detection For more information, please visit > www.hawkmeasure.com Unit must have T mounting thread
More information3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement
Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and
More informationUltrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.
Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. A Sarasota 2000 Ultrasonic flowmeter, installed at Watchgate water treatment works in Cumbria on the 2.4m
More informationGladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation
Overview Gladiator Microwave Series A Higher Level of Performance Data Sheet Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More information3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement
Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationHAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationSpecification DataFile
DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming
More informationOEM radar transmitter, for aggressive media level measurement
OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type
More informationHAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationProcess Protection Acoustic sensors for pump monitoring
coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement
More informationSerie NW - Acoustic Wave. Option list. Applications / Overview
Nivowave Continuous level measuring system 1 Serie NW - Acoustic Wave Table of contents Page Applications / Overview Overview / Function P Mounting P Remote control P Technical Data P P Transducer selection
More informationprocess measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters
process measurement solutions Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters IP2045 MSP Advanced ultrasonics This new family of ultrasonic non-contacting liquid level transmitters is
More informationOperation. LEVEL Transmitters
Ultrasonic compact level transmitters for liquids echork GNRL DSCRIPION he high performance level transmitters are based on NIVLCO s 30 years of experience with ultrasonic level measurement. Whether for
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More information3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.
& 4 Wire Self ompensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. FETURES S.S. 1L Face Material c/w Tri-lamp Mtg. Base Simple push-button calibration (ccurate) Output 4-20 m / 20-4
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More information713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor US 3.1 713 100505 As our products are continuously improved, we reserve the right to make
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationUltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER
UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.
More informationUltrasonic level measuring device, non-contact
Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB
More informationTHE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)
THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller
More informationMobrey open channel flow measurement systems
Technical specification sheet IP2039 July 2007 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationUltrasonic Level Transducer Type: MPUL06 Article No.: ca. 122
Type: Article No.: 0067720.006 Dimensions ø95 PG7 45.25 16 101 ca. 122 ø53 NPS 2" Figure 1: Ultrasonic Level Transducer Description and application The MPULxx is an ultrasonic transducer used for determining
More informationPanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits
GE Measurement & Control PanaFlow HT Panametrics Ultrasonic SIL Flow Meter for Liquids pplications PanaFlow HT is a SIL-rated flow meter used for flow measurement of liquids in either nominal or extremely
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationA Higher Level of Performance. Data Sheet. Hydrobar. Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Hydrobar Level Transmitters For more information, please visit > www.hawkmeasure.com Overview Hydrobar Overview Description Submersible level transmitters The Hydrobar
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display
More informationGladiator. Doppler Microwave Series. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. Product Flow Detection Circular Polarisation
Sultan Sonar Manual Rev.0 A Higher Level of Performance Manual Gladiator Doppler Microwave Series Product Flow Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com Table
More informationConnecting Mains Electrical Power
Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required
More informationSITRANS L Level instruments
SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches
More informationLST100 Ultrasonic level transmitter for upstream oil and gas
Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors,
More information2-wire level transmitter
Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2
More informationBeamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments
Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR 63 Made for extreme environments Made for extreme environments 64 MC5-IS: designed for use in potentially explosive environments The ATEX- and
More informationSolenvis SL93 Open Channel / Flume Meters
Solenvis SL93 Open Channel / Flume Meters DMDF-OP-C Flumes and Weirs Ultrasonic Flow Meters Principle Direct measurement of this product relies on the level. When using this product for open channel measurement,
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationLST400 Ultrasonic level / open channel flow transmitter
Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationCHANFLO 2500 / 3000 Open Channel Flowmeters
Flow measurement CHANFLO 2500 / 3000 Open Channel Flowmeters DCHANUS0108 General measures the flow rate of water or wastewater in all types of weirs and flumes and provides a display of both current flow
More informationOpen Channel Flowmeter 713
Open Channel Flowmeter 713 General Flow Converter 713 is designed for measuring and recording water flow in open ducts and channels. Flow Converter 713 is a complete instrument for the measuring of instantaneous
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationData Acquisition Modules/ Distributed IO Modules
User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationSITRANS F US Clamp-on
Siemens G 2013 Overview Standard volume Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity Batch interface and product quality diagnostics provided Density
More informationModel S50-D Density Sensor Specifications
Issue/Rev. 0.1 (4/99) S-Mass Meter S50-D Density Specifications ulletin SS0M020 The S-Mass Density derives its name from the S-shaped tubes of the flow sensor. This patented geometry produces a high signal-to-noise
More informationGas Mass Flow Control Products
Gas Mass Flow Control Products The Standard of Excellence in Mass Flow Porter Mass Flow products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement
More informationMULTICONT MULTICHANNEL PROCESS CONTROLLER
MULTICONT MULTICHANNEL PROCESS CONTROLLER O U R P R O F E S S I O N I S Y O U R L E V E L S Y S T E M S APPLICATION The MULTICONT is a universal interface between Nivelco's HART-capable intelligent level
More informationEchotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow
Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow DESCRIPTION Echotel Model 338 is a two-wire, loop-powered noncontact transmitter for liquid level,
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationMODEL: 27HU 27-UNIT MODEL: 27HU [1][2]
Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication
More informationUltrasonic level meters ULM 70
průmyslová elektronika Ultrasonic level meters ULM 70 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, drains, etc.
More informationNon-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
More informationM-2111 Series Ultrasonic Flow Meter
M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination
More informationEchotel Trident 91S/92S Ultrasonic Level Switches
Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma
More informationBM SERIES ULTRA COMPACT ULTRASONIC LEVEL INSTRUMENTS (Compact version)
ULTRSONIC LEVEL INSTRUMENTS (Compact ) DESCRIPTION The ultrasonic impulses generated from transducers antenna system, which travel at the speed of sound, come reflected by the surface of medium and newly
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationULTRASONIC LEVEL INDICATOR
ULTRASONIC LEVEL INDICATOR REFLEX/SCANFLEX MULTIFLEX MINIFLEX LR MICROFLEX-C TYPICAL NON-CONTACT LEVEL METER! OUTSTANDING SOFWARE MAKES HIGHLY STABLE AND RELIABLE. A WIDE RANGE OF S FROM SOLIDS TOLIQUIDS,
More informationNCR-80. BinMaster Price Book binmaster.com Subject to change without notice 1
NCR-80 inmaster Price ook 01-2019 binmaster.com Subject to change without notice 1 NCR-80 NCR-80 Non-contact radar continuously measures the level of powders, granules, solids, or liquids in a vessel.
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter
ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced
More informationTEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions
Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationMULTICONT OUR PROFESSION YOUR LEVEL
MULTICONT M U LT I C H A N N E L P R O C E S S C O N T R O L L E R OUR PROFESSION IS YOUR LEVEL APPLICATION The MULTICONT is a universal interface between Nivelco's HART-capable intelligent level transmitters
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com
More informationUltrasonic Level Transmitter.
Ultrasonic Level Transmitter www.fine-tek.com INTRODUCTION The ultrasonic level transmitter is a non-contact, low-cost and easy-to-install measuring device. It can be applied to most industrial applications
More information905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use
Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at
More informationManufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.
EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More information