HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)
|
|
- Kellie McDonald
- 5 years ago
- Views:
Transcription
1 Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit >
2 Model HLT Transmitter with Analog Output and HART Product overview The Model HLT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass chamber) applications. The Model HLT transmitter provides a 4-20 ma output for most magnetic level gauge manufacturers and allows for mounting external to the chamber without interrupting the process. Model HLT transmitters are modular in design offering a selection of mounting options and pipe styles. The modularity also offers simple field replacement. Subject to local electrical codes, the sensing element and electronics can be removed from the transmitter pipe without disturbing the operation of the process saving both time and money. The model HLT transmitter uses HART communication for setup, calibration, and diagnostics. HART can be utilized via a hand-held communicator or with the HAWK setup software via a PC and HART to serial converter. The optional on-board display and keypad is also provided for local indication and programming. Features Applications Markets 4 to 20 ma Analog Output with HART No Scheduled Maintenance or Recalibration High Accuracy and Repeatability AMS Aware Explosion-proof and/or Intrinsically Safe Inventory Control Process Vessel Bypass Chamber Petroleum and Petrochemical Power Generation Specialty Chemical All specifications are subject to change. Contact HAWK for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. 2
3 Product specifications Parameters LEVEL OUTPUT Specifications Measured Product level variable: Total Level or Interface Level Output signal / Protocol: 4 to 20 ma with HART Order length: Rigid pipe: 508 mm (20 in.) to 3658 mm (144 in.) Contact factory for longer lengths. Order length equals the measurement range plus the inactive zone. Non-linearity: 0.02% F.S. or mm (1/32 in.) * * Whichever is greater Repeatability: 0.01% F.S. or mm (0.015 in.) * (any direction) Contact factory for alternative materials. COMPATIBILI TY MRA3/4 chamber compatibility: ELECTRONICS Input voltage: Fail safe: Reverse polarity protection: Lightning/ Transient protection: CALIBRATION Zero adjust range: Span adjust range: HAWK K-Tek Jerguson Kenco Wika Klinger Quest-Tec Vize Penberthy Others 10.5 to 36.1 Vdc, 28 Vdc maximum for I.S. ATEX approval High (21.4 ma), or Low (3.8 ma) Series diode Stage 1: Line-to-ground surge suppression; IEC Stage 2: Line-to-line and line-to-ground transient suppressors; IEC Anywhere within the active length Full scale to 152 mm (6 in.) from zero Parameters ENVIRONMENTAL Enclosure rating: Humidity: Operating temperatures: FIELD INSTALLATION Housing dimensions: Specifications NEMA Type 4X 0 to 100% relative humidity, non-condensing Electronics: -40 C (-40 F) to 71 C (160 ºF) Sensing element: -40 C (-40 F) to C (257 F) Higher temperatures are available using a small insulation pad.. Contact factory for specific temperature ranges. Single cavity: 127 mm (5 in.) by 123 mm (4.85 in.) 121 mm (4.75 in.) O.D. MOUNTING Rigid pipe: Hose clamp to chamber WIRING Connections: 2-wire shielded cable twisted pair, ELECTRICAL CONNECTIONS Dual Single Compartment Cavity: Housings: ¾ in. conduit 3/4 in. opening, conduit opening, M20 M20 for for ATEX Version Single Cavity: 3/4 in. conduit version opening, M20 for ATEX Version DISPLAY Measured variables: Product level Size: 13 mm (0.5 in.) Number of digits: 16 3
4 Agency Approvals explosion proof FM 3615 C22.2 No. 30 Class I, Division 1, Groups B, C and D Class II, Division 1, Groups E, F and G Division 1, NEMA Type 4X Explosion-proof housing required 90 electronic mount is only for Groups C and D Intrinsically safe FM 3610 C22.2 No. 157 en Class I, Division 1, Groups A, B, C and D Class II, Division 1, Groups E, F and G Class III, T4 Division 1, NEMA Type 4X PTB 00 ATEX 2069X II 1/2 G bzw. II 2 G EEx ia IIB T4 bzw. EEx ia IIA T4 HART ART handheld communicator programming The Model HLT transmitter programming can also be performed by using handheld HART communicator device such as the Rosemount 375 or 475. Setpoint programming using the display Any Model HLT transmitter that is purchased with a display has the ability to adjust the 4 and 20 ma setpoints by pressing the appropriate button located at the bottom of the display. 4
5 Product dimensions and mounting HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see Figure 1 ). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG. The Model HLT transmitter Measuring Range is equal to the Order Length minus the Inactive Zone. The Measuring Range should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG. Current Pulse Start pulse Magnetic Float Assembly 132 mm (5.19 in.) mm (8 in.) Sensor Wire Inactive Zone 95.3 mm (3.75 in.) Measuring Range Order length Inactive Zone 76.2 mm (3 in.) Figure 1 5
6 Product dimensions and mounting HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see Figure 2 ). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG. The Model HLT offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree fitting allows the electronic head of the Model HLT to be positioned to the side of the pipe allowing for simpler mounting. The Model HLT transmitter Measuring Range is equal to the Order Length minus the Inactive Zone. The Measuring Range should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG. 2 ft ft Figure 2. Model MRA3/4 mounting, top and bottom flange Figure 2 6
7 Ordering information for FM-CSA approvals Agency Approvals 1 Model M Magnetostrictive Gauge 2 Type R Analog Transmitter 3 Approval Agency F FM FM 4 CSA CSA 4 Output ma High Gain w/ Display, 1 Loop All ma High Gain w/o Display, 1 Loop All B Single cavity (XP) 5 Housing Type C D Dual cavity (XP)* Single cavity (XP) w/ Display window All E Dual cavity (XP) w/ Display window* *Dual cavity requires electronic mount 90 degree bend 1 Integral Electronics All 3 90 degree bend, housing top left 6 Electronics Mounting 4 90 degree bend, housing top right 5 90 degree bend, housing bottom left 6 90 degree bend, housing bottom right All 7 Sensor Pipe B Industrial Pipe (5/8 in OD) All R Industrial Pipe (1/2 in OD) All 8 Material of Construction 1 316L SS 9 Process Connection Type X None 10 Process Connection Size X None 11 Temperature Element 0 None 12 Unit of measurement 13,14,15,16,17 Length 14 Special M U S E Metric US Customary XXX.XX Inches XXXXX mm Standard product Engineered Special (>144 w/ factory approval) 7
8 Ordering information for ATEX and IECEx approval Agency Approvals 1 Model M Magnetostrictive Gauge 2 Type R Analog Transmitter E ATEX Approval ATEX Ex d or Ex ia H IECEx Approval IECEx Ex d 3 Approval Agency B INMETRO Approval INMETRO Ex d K KC Approval KC Ex d P CCoE Approval CCoE Ex d 4 Output ma High Gain w/ Display, 1 Loop All ma High Gain w/o Display, 1 Loop All B Single cavity (XP) C D Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, IECEx, INMETRO, KC, CCoE, Ex d Only E Dual cavity (XP) w/ Display window* G Single cavity (XP) 5 Housing Type H J Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, Ex ia IIA K Dual cavity (XP) w/ Display window* R Single cavity (XP) S T Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, Ex ia IIB U Dual cavity (XP) w/ Display window* *Dual cavity requires electronic mount 90 degree bend 1 Integral Electronics All 3 90 degree bend, housing top left Ex d Only 6 Electronics Mounting 4 90 degree bend, housing top right Ex d Only 5 90 degree bend, housing bottom left Ex d Only 6 90 degree bend, housing bottom right Ex d Only 7 Sensor Pipe B Industrial Pipe (5/8 in OD) All R Industrial Pipe (1/2 in OD) All 8 Material of Construction 1 316L SS 9 Process Connection Type X None 10 Process Connection Size X None 11 Temperature Element 0 None 12 Unit of measurement M Metric U US Customary 13,14,15,16,17 Length 18 Special S E XXX.XX Inches XXXXX mm Standard Engineered Special (>144 w/ factory approval) 8
9 Programming and hardware accessories HARDWARE HarDWare PART Part NUMBER NuMBer Hart to rs-232 adapter (SMAR H1-311) FM APPROVED 9
10 HAWK, Since 1988 Hawk Measurement Systems Pty Ltd (HAWK) was established in It's founding members saw the universal requirement of various industries requiring improved process control and efficiency in their operations. We Can Help HAWK understands the difficulties customers face when seeking accurate level measurement. Every application is different, involving a multitude of environmental factors. This is where HAWK excels. Our aim is to ensure that customers not only feel comfortable with our technology, but that we also to ensure a consistent and reliable solution is in place for the long term. We believe that a combination of application and product expertise, as well as forward thinking and proactive support policies are the foundation of successful customer-supplier relationships. 10
11 Progressive Technical Support HAWK believes that the future of the Level Measurement Industry revolves around the quality of pre and post sales - support. Our aim is for all sales & support staff to be product experts, and more importantly application experts making our customers applications as efficient and consistent as possible. Remote Innovation HAWK understands the need for immediate technical assistance. Knowledge Sharing HAWK believes that knowledge sharing is key to creating long term relationships. Empowering our customers and our worldwide distribution network, whilst being available at all times to lend a helping hand, is the perfect recipe for long term solutions and relationships. HAWK openly extends an invitation to share our 25 years of level measurement experience, and ensure that your day to day processes are efficient, understood, and always working. The HAWKLink 3G communication device allows any computer with internet access and our free GosHawK diagnostic & calibration software; to dial in, calibrate, test, and check the performance of HAWK products. This innovative system allows our Global Support Team to assist with commissioning and after sales service of HAWK equipment worldwide. Measurement problems are addressed as they happen; not days or weeks later. 11
12 A Higher Level of Performance Hawk Measurement Systems Hawk Measurement (Head Office) 96 Glenn Street Maurice Court Lawrence, MA 01843, USA Nunawading VIC 3131, AUSTRALIA Phone: HAWKLEVEL ( ) Phone: Phone: Fax: Fax: info@hawk.com.au info@hawkmeasure.com For more information and global representatives: Represented by: DOC-MLT-ICSA-FM-DAT 0315
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20
More informationLevel Plus. CHAMBERED Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology CHAMBERED Designed for Magnetic Level Gauge (MLG) No Scheduled Maintenance or Recalibration Hazardous Area Certified MEASURING
More informationA Higher Level of Performance. Data Sheet. Hydrobar. Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Hydrobar Level Transmitters For more information, please visit > www.hawkmeasure.com Overview Hydrobar Overview Description Submersible level transmitters The Hydrobar
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Tank SLAYER 3-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration
More informationLevel Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology SoCLEAN Sanitary and Electropolished Finish Inherent Accuracy ±1 mm No Scheduled Maintenance or Recalibration Hazardous
More informationLevel Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology RefineME 4-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration
More informationAT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products
Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Tank SLAYER 3-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration
More informationGladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
Higher Level of Performance Data Sheet Gladiator G1 Series Microwave Waveguide Information eam lockage Detection For more information, please visit > www.hawkmeasure.com G1R or G1S Waveguide oncept M-WG01
More informationGladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
Higher Level of Performance Data Sheet Gladiator G Series Microwave Waveguide Information eam lockage Detection For more information, please visit > www.hawkmeasure.com Unit must have T mounting thread
More informationAT200 External Mount Magnetostrictive Level Transmitter
Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationSultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The
More informationSultan Liquid- Acoustic Wave Technology
A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Principle of Operation The ORCA Sonar
More informationAT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products
Data sheet DS/AT100S-EN Rev. N AT100S Magnetostrictive Level Transmitter Sanitary magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* High Accuracy:.01% of Full Scale Superior
More informationLevel Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology BRIEF OPERATION MANUAL FOR SAFE USE M-Series Model MR Analog Transmitter UNITED STATES GENERAL: Tel: +1-919-677-0100 Fax:
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Sultan Sonar Level System System Principle
More informationLevel Plus Liquid-Level Sensors With Temposonics Technology
Level Plus Liquid-Level Sensors With Temposonics Technology M-Series Model MR Analog Transmitter SENSORS Document Part Number 550720 Revision G Operation and Installation Manual United States General:
More informationLiquid Level Transmitter Model MC420 Analog Output
l L e v e l P l u s Liquid Level Transmitter Model MC420 Analog Output Operation and Installation Manual 550760 Revision A Table of Contents Section Page 1 INTRODUCTION 1 2 PRODUCT DESCRIPTION 2 2.1 MC420
More informationDREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance
DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationFICHA TÉCNICA DE PRODUTO
FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:
More informationSultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationDREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar
DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement
More informationTEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions
Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain
More informationProcess Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors
Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More information7250 Series HR Digital Stik
Series 7250 Product Manual CONTINUOUS LEVEL CONTROLS 7250 Series HR Digital Stik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS 1 AUTOMATION & PROCESS TECHNOLOGIES 7250 Series Manual Overview
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationLevel Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology BRIEF OPERATION MANUAL FOR SAFE USE M-Series Model MG Digital Transmitter UNITED STATES GENERAL: Tel: +1-919-677-0100
More informationFeatures. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.
Model L2610 Instrumentation designed with the user in mind. NULL-KOTE Self-Diagnostic Analog Level Transmitter Electronic, RF Impedance sensing, with the innovative NULL-KOTE system, which ignores product
More informationSultan Acoustic Wave Series
A Higher Level of Performance Data Sheet Sultan Acoustic Wave Series Machinery Positioning Systems For more information, please visit > www.hawkmeasure.com Principle of Operation The Sultan for Machinery
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationD E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter
Magnetostrictive Transmitters D E S C R I P T I O N The Enhanced Jupiter Magnetostrictive level transmitter provides a 4 20 ma output proportional to the level being measured or FOUNDATION fieldbus output.
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationDREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET
t DREXELBROOK DATA SHEET DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationFlow Level Temperature Pressure Valves Analyzers Accessories TekValSys
Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationDOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200
DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationSITRANS LR 300: High Performance Radar for Level Measurement
SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationGladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation
Overview Gladiator Microwave Series A Higher Level of Performance Data Sheet Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationSubmersible pressure sensor For superior applications Model LF-1
Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationWireless Base Radio. Wireless Transmitters
XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationKotron Model 82 CE RF Level Transmitter
Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationHumidity Sensor/Transmitter Assembly
Humidity Sensor/Transmitter Assembly Wall/Duct Space Outside Air (OSA) Overview Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing
More informationPositioner with HART Communication Type 3780
Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationRF Capacitance Level Controls
CAC-8A-00-6 681R7 Features and Benefits Reliability Low maintenance costs No moving parts Interface measurement with on/off and continuous output Unaffected by changes in pressure, temperature, specific
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationPNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.
PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic
More informationRF Capacitance Level Controls
SEE MORE AT SORInc.com Request Quote RF Capacitance CAC-8A-00-6 68R7 Features and Benefits Reliability Low maintenance costs No moving parts Interface measurement with on/off and continuous output Unaffected
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationLiquid-Level Transmitter Model M-Series Analog Output
l L e v e l P l u s Liquid-Level Transmitter Model M-Series Analog Output Operation and Installation 550720 Revision F TABLE OF CONTENTS Section Page Notices used in this book iii Related publications
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationKMS-2 Exd Magnetostrictive Level Transmitter
Installation and Operating Instructions KMS-2 Exd Magnetostrictive Level Transmitter Revision F 20/09/2018 ATEX KMS-2 Ex d Transmitter Contents Symbols Used...1 Safety information...1 Introduction...2
More informationSMARTLINE LEVEL SLG700
Tom Brans Date SMARTLINE LEVEL SLG700 Guided Wave Radar Update Honeywell ENRAF legacy 1 1 Insert Text Here - Secondary Bullet Tertiary Bullet Over 60 years of tradition Winning Terminal Inventory Solutions
More informationProcess display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationTechnologies, Solutions, and Applications. Guided Wave Radar for Level
Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8
More informationSpecification DataFile
DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming
More informationTemposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Analog and Start/Stop Outputs SENSORS Document Part Number: 550996 Revision E Data Sheet FEATURES Linear, Absolute Measurement
More informationENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.
ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters
ABB MEASUREMENT & ANALYTICS DATA SHEET TB8 -wire conductivity transmitters TB 8 -W I R E CON DUCT I VI T Y TR ANSMIT TE RS DS/ TB8 -E N RE V. H Measurement made easy Loop-powered transmitters that reduce
More information