Flow Measurement SITRANS F US Clamp-on
|
|
- Duane Grant Hamilton
- 6 years ago
- Views:
Transcription
1 Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors, precision volume or standard volume flowmeters. Benefits For all SITS FUH1010 products Easy installation; no need to cut pipe or stop flow Minimal maintenance; external sensors do not require periodic cleaning o moving parts to foul or wear o pressure drop or energy loss Wide turn-down ratio, 0:1 Choice of single, dual, or optional, three or four path versions. - Single path version reduces initial investment - Two or optional three and four path versions provide higher accuracy, especially where limited straight run or poor flow profile exists WideBeam technology - Helps provide improved accuracy over a wide range of liquid conditions and flow rates - ccommodates pipelines transporting multiple liquid products ZeroMatic ath automatically corrects for zero drift without stopping flow Interface detection Outputs liquid density and I as a direct replacement for intrusive densitometers Exceptional repeatability is maintained, independent of changes in temperature, pressure or viscosity o need for straight run recision volume Moderate cost recise measurement is maintained with automatic "eynolds umber" compensation for temperature and viscosity changes. Standard volume (High end system) Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity Batch interface and product quality diagnostics provided Density and I outputs provided Scraper ( pig ) detection provided pplication Interface detection recise identification of interfaces on multi-liquid pipelines roduct identification Density indication recision volume pplications with multiple liquids having a wide viscosity range utomatic gross volume compensation due to viscosity changes Standard volume (High end system) Standard (net) volume flow measurement Suitable for use in leak detection systems Mass flow output measurement Interface detection "ig" detection Chemical and petrochemical processing Design SITS FUH1010 is available in two enclosures: I65 (EM 4X) wall mount enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single path - Dual path - Optional four path I66 (EM 7) wall mount explosionproof enclosure constructed of cast aluminum, stainless steel hardware, with glass window - Single path - Dual path - Four path (optional) There are 2 types of mounting assemblies - luminum mounting frames (default) - Stainless steel High precision mount (optional) Function I65 (EM 4X) and I66 (EM 7) flowmeters have integral button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away Current, voltage, status alarm, frequency outputs and communications HT, BCnet MST/BCnet I, Modbus TU & TC/I, Ethernet I, Johnson 2, VT100 S 22 (see specification section for details) nalog inputs (see specification section for details) ZeroMatic ath automatically corrects for zero drift Bidirectional flow operation 1 MByte data logger with both site and data logger storage English, Spanish, German, Italian and French language options /81
2 Technical specifications Specifications for interface detectors ccuracy ccuracy 0.05 of I o. epeatability 0.01 of I o. Specifications for volumetric and mass flowmeters Input Flow range 12 m/s ( 40 ft/s), bidirectional Flow sensitivity m/s (0.001 ft/s), flow rate independent ccuracy Typical accuracy 0.5 to 1 % of flow Calibratable accuracy 0.15 % 0. % of flow, depending on version Batch repeatability 0.05 % of flow, maximum Specifications for all SITS FUH1010 products Input ipe size 6.4 mm m ( ) nalog inputs Current: 4 x m Output Standard outputs Current: 20 m (1 k at 0 VDC) Voltage: 10 V DC (5 k minimum) ulse ate: 5 khz, Digital uad. VT100 S 22 Extended outputs HT, BCnet MST/BCnet I, Modbus TU & TC/I, Ethernet I, Johnson 2 4 x m Form C relays Digital pulse Status/larm I/O rogrammable relays Totalizer clear switch input (not for I65 (EM 4X) enclosure) 1) Totalizer hold switch input ccuracy Zero Drift m/s (0.001 ft/s), with ZeroMatic ath active (not provided for interface detector) 5 Hz Data refresh rate ated operation conditions Degree of protection Wall mount I65 (EM 4X) Wall mount explosionproof I66 (EM 7) Liquid temperature Standard C ( F) Optional C ( F) mbient temperature C ( F) Design Dimensions see "System info and selection guide" Weight ower supply I65 (EM 4X) wall mount and I66 (EM 7) wall mount explosionproof Indication and operation Data logger memory Display I65 (EM 4X) and I66 (EM 7) Enclosures Keypad I65 (EM 4X) and I66 (EM 7) Enclosures Language options see diagrams V C, Hz, 0 V or V DC, 12 W 1 MByte 128 x 240 pixel LCD with backlight keypad buttons with tactile feedback English, Spanish, German, Italian, French 1) Totalizer switch inputs are not provided for the interface detector. /82
3 Certificates and approvals I65 (EM 4X) wall mount enclosure FM and CS CE C-TICK TEX I66 (EM 7) wall mount explosionproof enclosure ratings FM and CS CE TEX Transmitter -I Class I, Div 2 S Class II, Div 2 Sensor I.S. Class I, II, Div 1 EMC Directive 2014/0/EU TEX Directive 2014/4/EU Transmitter: Ex II (1) G [Ex ia] IIC EX II (1) G Ex nc [ia] IIC T5 Sensors: Ex II 1 G Ex ia IIC T5 Transmitter X Class I, Div 1 D-I Class II, Div 1 -I Class I, Div 2 S Class II, Div 2 Sensor I.S. Class I, II, Div 1 EMC Directive 2014/0/EU TEX Directive 2014/4/EU Transmitter: Ex II (1) G [Ex ia] IIC Ex II (1) G Ex nc [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB + H2 T5 Sensors: Ex II 1 G Ex ia IIC T5 /8
4 Standard MLFB for quick delivery on Selection and Ordering data rticle o. Order code 7 M E K K Click on the rticle o. for the online configuration in the I Life Cycle ortal. Design I65 (EM 4X) wall mount 0 umber of ultrasonic paths/meter type Dual path Standard Volume 4 Flowmeter functions and I/O configurations includes graphic or digital display, I66 (BB6665 (EM 4X)) and I66 (EM 7) wall mount explosionproof units: Standard I/O - Graphic display - 2 x V - 2 x m (active) - 2 x khz pulse outputs (TTL) - 4 x form C relays - 4 x logic inputs (totalizer control, TTL) - 4 x m analog input - 1 x t100 TD input per channel Meter power options V C Communication options VT100 S 22 0 TD temperature sensor (includes mounting hardware for pipes above 1.5 /8 mm OD) o TDs 0 1 x standard clamp-on TD 1 2 x standard clamp-on TD 2 1 x submersible clamp-on TD 2 x submersible clamp-on 4 TD otes: 1. Temperature input is required for SITS FUH1010 systems 2. Only the Interface detector set up as a dual channel can use 2 TD s Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diam. listed) C2H (high precision) 1) 600 mm (24") D1H (high precision) 1) D4H (high precision) 1) D1H (high precision) 1) High Temperature to 104 C/220 F Z 1 Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See "Sensor selection charts" for specifications. C2H (high precision) 1) 600 mm (24") D1H (high precision) 1) D4H (high precision) 1) D1H (high precision) 1) High Temperature to 104 C/220 F Z 1 pprovals FM/CS/CE (default) 1 TEX, CE, C-TICK 2 Standard MLFB product offering represents 4 to 6 weeks delivery time 1) Made with stainless steel constuction. For sensor and TD cables for quick delivery see tables at end of section. /84
5 Selection and Ordering data rticle o. Ord. code I65 (EM 4X) wall mount I66 (EM 7) wall mount explosionproof 7ME600-7ME60- Click on the rticle o. for the online configuration in the I Life Cycle ortal. umber of ultrasonic paths/meter type Single path (precision volume) 0 Single path (interface detector) 1 Dual channel/dual path (interface detector) 2 Dual path (precision volume) Dual path (standard volume/mass) 4 Special: Four path (standard volume/mass) 9 H 1 only Flowmeter functions and I/O configurations Includes graphic or digital display I65 (EM 4X) wall mount and I66 (EM 7 wall mount explosionsproof) units Standard I/O - Graphic display - 2 x V - 2 x m (active) - 2 x khz pulse outputs (TTL) - 4 x form C relays - 4 x logic inputs (totalizer control, TTL) - 4 x m analog input - 1 x t100 TD input per channel (Dual channel/path) - 1 x t100 TD input (Multi channel/path) Extended I/O C - Graphic display - 2 x V - 2 x m (active) - 2 x m (passive) - 2 x khz pulse outputs (TTL or OC) - 4 x form C relays - 4 x logic inputs (totalizer control, TTL) - 4 x m analog input - 1 x t100 TD input per channel (Dual channel/path) - 1 x t100 TD input (Multi channel/path) Meter power options V C V DC B Communication options VT100 S 22 0 HT, BCnet MST/BCnet I, Modbus TU 2 & TC/I, Ethernet I, Johnson 2, VT100 S 22 Selection and Ordering data rticle o. Ord. code I65 (EM 4X) wall mount 7ME600- I66 (EM 7) wall mount explosionproof 7ME60- TD temperature sensor (includes mounting hardware for pipes above 1.5 OD) o TDs (ote: temperature input is required 0 for SITS FUH systems) 1 x Standard clamp-on TD 1 2 x Standard clamp-on TD 2) 2 1 x Submersible clamp-on TD 2 x Submersible clamp-on TD 2) 4 Sensor for channel/path 1 (includes standard pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. (-40 F to +248 F), nominal 21 C (70 F): 2H (high precision) Trackmount and straps H 75 mm ( ) H (high precision) Trackmount and straps J 75 mm ( ) B1H (high precision) Trackmount and straps K B2H (high precision) Trackmount and straps L BH (high precision) Trackmount and straps T C1H (high precision) C2H (high precision) D1H (high precision) D2H (high precision) DH (high precision) D4H (high precision) M U /85
6 Selection and Ordering data rticle o. Ord. code I65 (EM 4X) wall mount 7ME600- I66 (EM 7) wall mount explosionproof 7ME60- Sensor for channel/path 1 (continued) (-40 F to +248 F), nominal 65 C (150 F): B1H (high temperature range H) Z 1 K B2H (high temperature range H) Z 1 L BH (high temperature range H) Z 1 T C1H (high temperature range H) Z 1 M C2H (high temperature range H) Z 1 D1H (high temperature range H) 1) Z 1 D2H (high temperature range H) 1) Z 1 DH (high temperature range H) 1) Z 1 U D4H (high temperature range H) 1) Z 1 Sensor for channel/path 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. (-40 F to +248 F), nominal 21 C (70 F): 2H (high precision) Trackmount and straps H 75 mm ( ) H (high precision) Trackmount and straps J 75 mm ( ) B1H (high precision) Trackmount and straps K B2H (high precision) Trackmount and straps L BH (high precision) Trackmount and straps T C1H (high precision) M C2H (high precision) D1H (high precision) D2H (high precision) DH (high precision) D4H (high precision) U Selection and Ordering data rticle o. Ord. code I65 (EM 4X) wall mount I66 (EM 7) wall mount explosionproof 7ME600-7ME60- (-40 F to +248 F), nominal 65 C (150 F): B1H (high temperature range H) Z 1 K B2H (high temperature range H) Z 1 L BH (high temperature range H) Z 1 T C1H (high temperature range H) Z 1 M C2H (high temperature range H) Z 1 D1H (high temperature range H) 1) Z 1 D2H (high temperature range H) 1) Z 1 DH (high temperature range H) 1) Z 1 U D4H (high temperature range H) 1) Z 1 pprovals FM/CS/CE/C-TICK (default), also for non 1 hazardous area TEX 2 1) Supplied spacer bar supports pipes up to 750 mm (0 inch). For pipes larger than 750 mm (0 inch) purchase also, spare part 7ME960-0MS40 (1012B-4). 2) Dual channel interface detector only Made with stainless steel construction. Selection and Ordering data Further designs lease add "-Z" to rticle o. and specify Order code(s). Cable assembly for sensors (add for # of paths) See "Sensor cable selection chart" Cable assembly for TDs (add for # of TDs) See "TD cable selection chart" Cable termination kit (for one cable pair) Termination for standard, plenum and armored sensor cable Termination for submersible cable TD cable termination kit for standard TD TD cable termination kit for submersible TD Cable gland kit Tag name plate Stainless steel tags with.2 mm (0.1 inch) characters (68 characters max.) Order code K.... T01 T11 T21 T1 T51 Y19 /86
7 Selection and Ordering data rticle o. Operating Instructions for SITS FUH1010 English EM 4X & EM 7 wall mount 5E Standard Volume German EM 4X & EM 7 wall mount 5E Standard Volume English EM 4X & EM 7 CO:1010VFM- wall mount explosionproof recision Volume English EM 4X & EM 7 5E wall mount explosionproof Interface Detector ll literature is available to download for free, in a range of languages, at MLFB example pplication example clamp-on meter is required for a 12 carbon steel hydrocarbon line flowing multiple products, with a wall thickness of 12.7 mm (0.5 ). Meter electronics are to be located in a Class I Div 2 area only 60 ft from the pipeline. 12 V DC power is available at the site. Dual path operation is desired for improved accuracy and redundant measurement. ulse output will be primary flow data source. MLFB rticle o.: 7ME600-CB00-1-Z K0 + K0 + 0 Selection and Ordering data rticle o. Ord. code SITS FUH1010 meter 7 M E family I65 (EM 4X) enclosure 0 Dual path precision volume Custody Transfer option with C digital pulse V DC power option B VT100 S 22 0 TD required for viscosity comp Sensor code for path 1 Sensor code for path 2 FM approval required 1 0 m (100 ft) sensor cable for path 1 K 0 0 m (100 ft) sensor cable for path 2 K 0 0 m (100 ft) cable for TD 0 High precision sensor selection chart I68 1) Made with stainless steel construction. Sensor Cable Selection Chart Sensor cable codes for length and type options 1) Standard MLFB for quick delivery TD Cable Selection Chart TD cable codes for length and type 1) Standard MLFB for quick delivery Based on pipe wall thickness (steel pipes only) Sensor Order ipe wall (mm) ipe wall (inch) ipe wall Code min. max. min. max. 1H G H H H J B1H K B2H L C1H 1) M C2H 1) D1H 1) D2H 1) D4H 1) BH 1) T DH 1) U Cable length m (ft) Standard (VC jacket) C ( F) Submersible (polyethylene jacket) C ( F) lenum ated (teflon jacket) C ( F) rmored Order code 6 (20) K01 1) K11 K21 K1 15 (50) K02 K12 1) K22 K2 1) 0 (100) K0 1) K1 1) K2 K 46 (150) K04 1) K14 K24 K4 61 (200) K05 K15 K25 K5 91 (00) K06 K16 K26 K6 Cable length m (ft) Standard (teflon wrapped) C ( F) Order code 6 (20) 01 1) (50) 02 1) 12 0 (100) 0 1) 1 46 (150) (200) (00) C ( F) Submersible (extruded jacket) C ( F) /87
SITRANS F US Clamp-on
Siemens G 2013 Overview Standard volume Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity Batch interface and product quality diagnostics provided Density
More informationAdvanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Clamp-on Ultrasonic Flow Meter Family System 1010P and 1010WP Portable Clamp-On Multifunction Ultrasonic Flowmeter Applications
More informationPanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits
GE Measurement & Control PanaFlow HT Panametrics Ultrasonic SIL Flow Meter for Liquids pplications PanaFlow HT is a SIL-rated flow meter used for flow measurement of liquids in either nominal or extremely
More informationApplications Features
GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationDigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features
GE Measurement & Control DigitalFlow XMT868i Panametrics Liquid Flow Ultrasonic Transmitter The DigitalFlow XMT868i liquid flow transmitter is a complete ultrasonic flow metering system for measurement
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationSITRANS F flowmeters SITRANS F US. Clamp-on ultrasonic flowmeters 4/257
Overview clamp-on ultrasonic flowmeters provide highly accurate measurement while minimizing installation time and maintenance expense. Benefits Easy installation; no need to cut pipe or stop flow Minimal
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDigitalFlow DF868 Panametrics Liquid Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The DF868 liquid flowmeter is a complete ultrasonic flow metering system for measurement of: Refined hydrocarbons Petroleum products Crude oil Lubricating oils Diesel and fuel oils Solvents
More informationMeasurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080
Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always
More informationLevel Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.
Level Transmitter / Controller / Indicator 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. 2.1 NEW Class 1, Division 1 Hazardous Areas Approved
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationSITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview
Flow Measurement Flowmeter SITRANS FC40 Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according
More informationDigitalFlow DF868. Panametrics Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features
GE Measurement & Control DigitalFlow DF868 Panametrics Liquid Ultrasonic Flowmeter Applications The DF868 liquid flowmeter is a complete ultrasonic flow metering system for measurement of: Water and wastewater
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationFlow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.
Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationTechnical specification FLUXUS F401 H2O
Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationTechnical Specification FLUXUS ADM 8x27
Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More informationMass and Volume Flow Transmitter
IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,
More informationDigitalFlow TM CTF878
DigitalFlow TM CTF878 Panametrics Correlation Tag Clamp-On Gas Ultrasonic Flow Meter Applications The DigitalFlow CTF878 clamp-on gas fl ow meter is a complete ultrasonic fl ow metering system for the
More informationProcess Protection Acoustic sensors for pump monitoring
coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationUltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER
UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.
More informationSITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview
SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler
More informationKATflow 230 Portable Clamp-On Ultrasonic Flowmeter
Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,
More informationTechnical specification FLUXUS WD
Technical specification FLUXUS WD Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview
Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer
More information21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply
21R14A Receiver 14 Control/1 Alarm/1 Safety relays Maintained Link Maintained Link. Loss of Maintained Link.. UL Rating UL 508 Environmental Rating... NEMA 4 14 control/1 alarm/1 safety relays Receive
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass
More informationAdvancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016
Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationULTRASONIC FLOW METER FT101
Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationOnline data sheet FLOWSIC600 GAS FLOW METERS
Online data sheet FLOWSI600 F H I J K L M N O P Q R S T US Ordering information Type FLOWSI600 Part no. On request In accordance with rticle 2 (4), this product does not fall within the scope of RoHS directive
More information3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement
Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and
More informationLST400 Ultrasonic level / open channel flow transmitter
Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,
More informationLevel Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd
Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level transmitter
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationOperation. LEVEL Transmitters
Ultrasonic compact level transmitters for liquids echork GNRL DSCRIPION he high performance level transmitters are based on NIVLCO s 30 years of experience with ultrasonic level measurement. Whether for
More informationModel CFT51 Digital Coriolis Mass Flow and Density Transmitter with HART or Modbus Communication Protocol
FIELD DEVICES FLOW Product Specifications Model CFT51 Digital Coriolis Mass Flow and Density Transmitter with HART or Modbus Communication Protocol PSS 1-2B7 C The Foxboro brand Model CFT51 Digital Coriolis
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationWireless Base Radio. Wireless Transmitters
XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationSeries 1000 and 2000 Transmitters with MVD TM Technology
Series 1000 and 2000 Transmitters with MVD TM Technology Micro Motion Series 1000 and 2000 Transmitters with MVD Technology The new approach to sensor electronics Only Micro Motion combines new MVD Technology
More informationMicro Motion Model 2400S Transmitters with MVD Technology
Product Data Sheet PS-00830, Rev. D March 2009 Micro Motion Model 2400S Transmitters with MVD Technology The Model 2400S transmitter provides next-generation MVD technology in a compact, space-saving design.
More informationUltrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.
Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. A Sarasota 2000 Ultrasonic flowmeter, installed at Watchgate water treatment works in Cumbria on the 2.4m
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationPaddle wheel flow controller for On/Off control
addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs
More informationSLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter
SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationModel S50-D Density Sensor Specifications
Issue/Rev. 0.1 (4/99) S-Mass Meter S50-D Density Specifications ulletin SS0M020 The S-Mass Density derives its name from the S-shaped tubes of the flow sensor. This patented geometry produces a high signal-to-noise
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationElectromagnetic Flowmeter
Data Sheet Electromagnetic Flowmeter MagMaster Loflo Industry-specific design for the water and waste water industries in diameters from 5mm ( /2 in.) to 6mm (24in.) Wide flow range with.25% accuracy Extended
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More informationGeneral Specifications
General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationProcess display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationGS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit
High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationS T T U S I N S T R U M E N T S
S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.
More informationOPTISONIC 6300 P Technical Datasheet
OPTISONIC 6300 P Technical Datasheet Portable ultrasonic clamp-on flowmeter User friendly operation through full colour graphic display and full keypad Quick and easy transfer of logged data to your PC
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter
ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced
More information3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement
Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin
More informationClamp-on ultrasonic flowmeters have six product families: max. 2% solids
System info and selection guide Ultrasonic flowmeters Overview Siemens offers two types of ultrasonic flowmeters, wetted flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationLiquid Ultrasonic Flow Meters
Liquid Ultrasonic Flow Meters Acadiana Flow Measurement School Lafayette, LA April 17-18, 2007 Liquid Ultrasonic Meter with Integral Transmitter Trans-Alaska Pipeline First Multi-path Ultrasonic Flow Meters
More informationLevel Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration
Siemens G 200 Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationMicro Motion Model RFT9739 Flow and Density Transmitter
Product Data Sheet PS-00024, Rev. B December 2007 Micro Motion Model RFT9739 Flow and Density Transmitter The Micro Motion Model RFT9739 transmitter works with Micro Motion sensors to provide precision
More informationInsertion Flow sensor for continuous flow measurement
Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface
More information