EMI Test & Debugging Solution

Size: px
Start display at page:

Download "EMI Test & Debugging Solution"

Transcription

1 EMI Test & Debugging Solution 1

2 EMI Analyzer Model : EA-300 CM/DM Noise Separation EUT Source Impedance Analysis Components Performance Simulation Various System Configuration Easy and Simple Operation Basic Filter Design Simulation Total, CM/DM Noise Analysis Total Mode Noise CM & DM Mode Noise EUT Source Impedance Analysis Principle of CM & DM Source Impedance Recommended Components Search CM Mode Filter Design Simulation DM Mode Noise Solution CM Mode Noise Solution 2

3 EMI Analyzer Specification EA-300 EA-2100 EA-100 Frequency Range 9kHz ~ 30MHz 30MHz ~ 300MHz (Low) (High) 9kHz ~ 30MHz Mode Selector Analysis Mode Signal Tracking Loss CM/DM Separation Signal Input Sensitivity Max RF Input Level Input Dynamic Range Line1, Line2, CM, DM Mode Differential, Common 9kHz~30MHz < 2dB 30MHz~300MHz < 3dB 9kHz~30MHz > 40dB 30MHz~300MHz > 30dB -97dBm (10dBuV) 0dB attenuator (110dBuV) 100dB 9kHz~30MHz < 2dB 9kHz~30MHz > 40dB Display 7 Inch wide VFD display Operating System Embedded XP 4 Button control 1 Button control Input Impedance 50Ω In/Output Connectors BNC 50Ω Power Input Voltage AC100V~ 240V 50/60Hz 10W DC 15V Only Battery Capacity 100min (12V / 1.2ah) Dimension (mm) W395 D185 H335 W365 D330 H150 W250 D260 H98.5 Weight (kg) 9.4 kg 6.6 kg 3 kg EUT Source Impedance Analysis Components Performance Simulation Basic Filter Design Simulation Standard unit Widely application model Training and Education application Portable type Chargeable Battery installed

4 Filter Analyzer Model : FA-300 EMI Filter Characteristics Analysis Capable to measure CM & DM mode CISPR17 / MIL-STD-220B EMI Filter Quality Control Inspection Report Function Capable to measure components ; Inductor and Capacitor Specification FA-300 FA-2100 Frequency Range 9kHz ~ 300MHz 10kHz ~ 300MHz Mode Selector Analysis Mode CISPR17.MIL-STD-220B Differential, Common Signal loss 10kHz~30MHz < 3dB 30MHz~300MHz < 5dB CM/DM Separation 10kHz~30MHz < 40dB 30MHz~300MHz < 30dB Input sensitivity Max RF Input -97dBm (10dBuV) 23dBm (130dBuV) Display LCD (10.2 ) VFD display Front panel control Touch Panel, Button & JOG 4 Button control Input Impedance Input Dynamic Range Input / Output Connector Test Table (FA-001) Input Voltage 50Ω 120dB BNC 50Ω Slide Door type (Option) AC100V~ 240V 50/60Hz 10W Dimension W380 D398 H216 (mm) W365 D330 H150 (mm) Test Table W385 D390 H216 (mm) W365 D330 H150 (mm) Spectrum Analyzer Operation File Save Installed Auto Auto Fully Automatic System Use with any brand of Spectrum Analyzer

5 Line Impedance Stabilization Network Amendment A2:2006 to CISPR EN :2004 Satisfy CISP25 & ISO Standards EMCIS Own design to measure CM & DM Grid Connected Power Converters Easy Access and Simple operation Design LN2-16N Impedance Phase angle Specification Model LN2-16N LN2-50N LN2-100A LN4-50N LN4-100A LN1-100C LN1-100S LN1-50 LN1-100 LN2-100T Frequency Range 9kHz~30MHz 9kHz~30MHz 9kHz~30MHz 9kHz~30MHz 9kHz~30MHz 100kHz~120MHz 100kHz~120MHz 10kHz~10MHz 10kHz~10MHz 150kHz~30MHz Network 50Ω / 5uH+1Ω 50Ω / 5uH+1Ω 50Ω /50uH + 5Ω 50Ω /50uH + 5Ω CM:150Ω, DM:15 0Ω Artificial Hand 220pF + 510Ω 220pF + 510Ω 220pF + 510Ω 220pF + 510Ω 220pF + 510Ω None None None None None Supply Line/Phase 2 / 1 2 / 1 2 / 1 4 / 3 4 / 3 1 / 0 1 / 0 1 / 0 1 / 0 2 / 1 Max. Current 16A 50A 100A 50A 100A 100A 100A 50A 100A 100A AC 60Hz 440V(L to L) 440V(L to L) 440V(L to L) 440V(L to L) 440V(L to L) 250V(L to Earth) 250V(L to Earth) 220V(L to Earth) 220V(L to Earth) None Max. Voltage AC400Hz None 120V(L to L) 120V(L to L) 120V(L to L) 120V(L to L) None None 75V(L to Earth) 75V(L to Earth) None DC 1kV(L to L) 1kV(L to L) 1kV(L to L) 1kV(L to L) 1kV(L to L) 600V(L to Earth) 600V(L to Earth) 500V(L to Earth) 500V(L to Earth) 1.5kV(L to L) Power Frequency DC~60Hz DC~400Hz DC~400Hz DC~400Hz DC~400Hz DC~60Hz DC~60Hz DC~400Hz DC~400Hz DC Output Mode Selector Test, Analysis Test, Analysis Test, Analysis Test, Analysis Test, Analysis None CISPR, ISO None None L1, L2, CM, DM Power In/Output Type-F(AC Soket) Type-Terminal Type-Terminal Type-Terminal Type-Terminal Type-Terminal Type-Terminal Type-Terminal Type-Terminal Type-Terminal RF output BNC 50Ω BNC 50Ω BNC 50Ω BNC 50Ω BNC 50Ω N-type 50Ω N-type 50Ω N-type 50Ω N-type 50Ω N-Type 50Ω Impedance Tolerance ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20Ω Phase Toterance ± 11.5 ± 11.5 ± 11.5 ± 11.5 ± 11.5 ± 11.5 ± 11.5 None None 0 ± 40 Coupling Capacitor 0.25uF 0.25uF 0.25uF 0.25uF 0.25uF 0.1uF 0.1uF 0.25uF 0.25uF Transformer LCL None None None None None None None None None >26dB Insertion Loss None None None None None None None None None >20dB(EUT ~ AE) Dimension (mm) W355 D358 H148 W300 D705 H262 W350 D530 H241 W705 D500 H261 W720 D634 H242 W160 D370 H150 W160 D370 H150 W400 D500 H280 W420 D520 H300 W368 D630 H213 Weight (kg) MIL-STD-461E/F DC LISN GCPC CISPR 25 Vehicle LN4-50N / 100A LN2-50N / 100A LN1-50 / 100 LN2 100T LN1-100C LN1-100S

6 Conducted Reference Source Model : CRS-1530 Providing reference source Avoiding measurement errors Comparing measurement site circumstance (EMC Lab ) Application * Authorized & Private EMC Lab * Research Lab/institutes * University/Colleges * Industries * Others Frequency Range 150kHz~30MHz Reference Signal Power Output Level Frequency Stability Low Voltage Detection Power Indicator DC 12V Battery 50dBuV ±3dBuV Quartz drive Buzzer LED Operating Temp. Range 15 ~ 55 Dimension Weight W65 D65 H120 (mm) 300 g Multi Power Line Interference Probe Model : MP-930 Usable on both power source, AC/DC Easy measurements on power line and the path noises Frequency Range Input Voltage Input Current Input Dynamic Range Insertion Loss Output Connector Test Voltage 9kHz ~ 30MHz AC220V 50/60Hz, DC380V 63mA AC50Hz(nom) 0.8mA DC max 70dB 100kHz~30MHz 2dB BNC DC1500V Probe Temperature Range -5 C to 55 C Relative Humidity 20% to 80% Dimension Test Table W38 D23 H9 (mm) 2.6 kg

7 Excellent filtering characteristics EMI Filter Maximized Performance Design Capabilities Industrial, Telecommunication, Military, Automotive DC~AC 440V 1Ph, 3Ph, 1A~400A, 10KHz~ 10GHz EMCIS EMI Filter Design Process Noise Measurement Total Mode(L1, L2) Noise Noise Analysis CM & DM Mode Layout, Structure Reduction Target Source Impedance Analysis CM or DM respectively (Limit +Margin) CM & DM (EUT under Load) Ground CM, DM Filter Design Filter Design per CM / DM Trial Test Total Mode Noise Finish/Approval EMCIS designs and supplies the EXACT filters what customers want, using EMCIS own measuring Instruments and software. No limit on application ; Industrial, Telecommunication, Military, Automotive DC~AC 440V 1Ph, 3Ph, 1A~400A, 10KHz~ 10GHz 7

8 EMCIS TECHNOLOGY IN EMI SOLUTION EMCIS Buidling, 77 Deokcheon-ro, Manan-gu, Anyang-Si Gyeonggi-DO, Korea TEL : FAX : emcis@emcis.co.kr Distributed by : Specification subjects to change without notice Cat. 16E Rev.01

Specification for Conducted Emission Test

Specification for Conducted Emission Test 1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5

More information

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free Two Line V-Network GLN-5040A 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com USER MANUAL GW INSTEK PART NO. ISO-9001 CERTIFIED

More information

1 of 6 03/12/2012 14:56 2012-12-03 HAMEG > Products > Accessories > Probes http://www.hameg.com/186.0.html P R O B E S H Z 5 6-2 * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents

More information

What is EMC/EMI. EMS (Immunity) RE RE

What is EMC/EMI. EMS (Immunity) RE RE Entrance to EMI What is EMC/EMI Classification of EMC EMC (Electro-Magnetic Compatibility) EMI (Emission) EMS (Immunity) EMI : Electro-Magnetic Interference EMS : Electro-Magnetic Susceptibility CE(RE)

More information

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications...

More information

Design and Verification of 400Hz Power Filter for Aircraft Switching Power Supply

Design and Verification of 400Hz Power Filter for Aircraft Switching Power Supply INTERNATIONAL JOURNAL OF CIRCUITS, SYSTEMS AND SIGNAL PROCESSING Volume 9, 25 Design and Verification of Hz Power Filter for Aircraft Switching Power Supply Ju-Min Lee, Heon-Wook Seo, Sung-Su Ahn, Jin-Dae

More information

EMC Precompliance Systems and Accessories Catalog

EMC Precompliance Systems and Accessories Catalog EMC Precompliance Systems and Accessories Catalog Agilent 84115EM EMC precompliance systems Agilent E7402A and E7405A EMC precompliance analyzers Agilent E7415A EMC measurement software Agilent EMC precompliance

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3000 EMI TEST RECEIVERS Fully IF digital EMI Receivers family for measurement of electromagnetic interference from

More information

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1

More information

ITG Electronics, Inc.

ITG Electronics, Inc. Mitigating EMI Problems & Filter Selection By Rafik Stepanian EMI Noise Generators A change of state (On/Off ) in an Electronic component has the potential to generate EMI. Typical examples are Electronic

More information

Surge Generator for MIL-STD 1275

Surge Generator for MIL-STD 1275 Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMF RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 5 4 EMI TEST... 6 4.1 DISTURBANCE VOLTAGE ON MAINS TERMINALS ( KHZ- MHZ)...

More information

V1.3. TBLC08 50mH AC-LISN TBLC08

V1.3. TBLC08 50mH AC-LISN TBLC08 V1.3 TBLC08 The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed

More information

1.0 Job Description 1.1 Client Information This EUT has been tested at the request of: Company: Spectronic Denmark A/S Contact: John Herlev Telephone: 011 45 863-87-222 Fax: 011 45 863-87-704 Email: jhe@spectronic-denmark.com

More information

ENY81 Coupling Network

ENY81 Coupling Network Version 01.00 ENY81 Coupling Network January 2008 For radio disturbance measurements on unshielded, symmetrical telecommunications ports Eight-wire network Radio disturbance measurements in line with CISPR

More information

QPI-5L. 14 Amp Active EMI Filter for 24 V DC Bus. Features. Description. Applications 查询 QPI-5L 供应商. QuietPower

QPI-5L. 14 Amp Active EMI Filter for 24 V DC Bus. Features. Description. Applications 查询 QPI-5L 供应商. QuietPower 查询 5L 供应商 5L QuietPower 14 Amp Active EMI Filter for 24 V DC Bus Description The 5 active EMI filter attenuates conducted common-mode (CM) and differential-mode (DM) noise over the CISPR22 frequency range

More information

HZ530 Near-Field Probe Set

HZ530 Near-Field Probe Set HZ530 Near-Field Probe Set The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with input impedance of 50

More information

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.

More information

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO 7637-2 FOR TESTS ACCORDING TO... > ISO 7637-2:2004 > ISO 7637-2:2011 TEST SET FOR THE MEASUREMENT OF AUTOMOTIVE TRANSIENT EMISSIONS

More information

True RMS Digital Multimeter Model:

True RMS Digital Multimeter Model: True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

50 μh Line Impedance Stabilisation Network (AC LISN)

50 μh Line Impedance Stabilisation Network (AC LISN) powered by 50 μh Line Impedance Stabilisation Network (AC LISN) More Infos: www.alldaq.com/tekbox Email: info@alldaq.com Sales hotline: +49 (0)89/894 222 74 We like to help you! ALLDAQ a division of ALLNET

More information

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the of cable and the intended signal carried on the cable. Teseq offers

More information

Prof. dr. ir. Johan CATRYSSE

Prof. dr. ir. Johan CATRYSSE EMC: How to handle large machinery Prof. dr. ir. Johan CATRYSSE FMEC, KHBO, Oostende (BE) MICAS/ESAT, KULeuven (BE) 1 Overview 2 Large Machinery EMC Directive and Harmonised Standards TEMCA2 project Conducted

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing

More information

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 10 80, Jeil-ri, Yangji-myun, Cheoin-gu, Yongin-si, Gyeonggi-do,

More information

MIL STD 461 E/F TEST REPORT. For. Model Number: WMRM920-PIP. Trade Name: itech

MIL STD 461 E/F TEST REPORT. For. Model Number: WMRM920-PIP. Trade Name: itech MIL STD 461 E/F TEST REPORT For Model Number: WMRM920-PIP Trade Name: itech Issued to itech Company LLC 41758 Christy Street, Fremont CA 94538 USA Issued by No. 11, Wugong 6 th Rd., Wugu Industrial Park

More information

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to MIL STD 461F TEST REPORT For Rugged PDA Model Number: P37B Trade Name: N/A Issued to ACA Digital Corporation 17F.,No 866-7, Zhongzheng Rd, Zhonghe City, Taipei County, 235, Taiwan, R,O,C Issued by Compliance

More information

EMI Pre-Compliance Testing Solution

EMI Pre-Compliance Testing Solution 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EMI Pre-Compliance Testing Solution GW Instek introduces the latest and comprehensive

More information

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz. ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz. Compact designed and manufactured in compliance with CISPR 16-1-1 For Measurements

More information

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations Model numbers: HT130022 Rev. B. December 17, 2002 Manufacturer: HQ, Inc. 210 9th Steet Drive Palmetto, FL 34221

More information

Test and Measurement for EMC

Test and Measurement for EMC Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring

More information

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN The EMI Receiver with built-in LISN 1 Model Frequency Range 7010/00 150 khz to 1 GHz 7010/01 9 khz to 1 GHz 7010/02 9 khz to 30 MHz 7010/03 9 khz to 3 GHz 2 family Built-in 16 A single phase LISN Artificial

More information

RF Signal Generator SM300

RF Signal Generator SM300 RF Signal Generator SM300 9 khz to 3 GHz With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen Germany

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) EMI Testing According to CSPR Publication 16 Recommendations Combining the 85685A RF preselector with the 8566B or 8568B

More information

416 Maetan 3-Dong, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do, Korea,

416 Maetan 3-Dong, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do, Korea, EMC TEST REPORT According to FCC CFR47 Part 18 Subpart C JOB Number : LBE20110882 1. This test report does not constitute an endorsement by NIST/NVLAP or U.S Government. 2. This test report is to certify

More information

Electromagnetic Compatibility

Electromagnetic Compatibility Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible

More information

LISN UP Application Note

LISN UP Application Note LISN UP Application Note What is the LISN UP? The LISN UP is a passive device that enables the EMC Engineer to easily distinguish between differential mode noise and common mode noise. This will enable

More information

R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications R&S ZV-Z5x Calibration Units Specifications Test & Measurement Data Sheet 09.01 Specifications apply under the following conditions: Sufficient warm-up time (approx. 15 minutes) at ambient temperature,

More information

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent 970-Series Handheld Multimeters Data Sheet Agilent 970-Series Handheld Multimeters Data Sheet Benchtop features and performance with handheld convenience and price 3 1 /2and 4 1 /2 digits with dcv accuracy to 0.05% 1 khz to 100 khz frequency response

More information

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave. 20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer

More information

FINE INSTRUMENTS CORPORATION

FINE INSTRUMENTS CORPORATION Model 41 Resistance USER S MANUAL a world leader in test & measurement FINE INSTRUMENTS CORPORATION B11, A-DONG, SMART VALLEY, SONGDOMIRAE-RO 3, YEONSU-GU, INCHEON, KOREA - TEL: (82-32) 837-5777 - FAX:

More information

Schlöder GmbH - EMC Test and Measurement Systems Model #

Schlöder GmbH - EMC Test and Measurement Systems Model # Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11

More information

GA GHz. Digital Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan 7 3447 GX oerden The Netherlands

More information

Voltage Sensors URV5-Z

Voltage Sensors URV5-Z Data sheet Version 05.00 Voltage Sensors URV5-Z May 2005 Universal voltage measurements from RF to microwaves The voltage sensors of the URV5-Z series are indispensable tools in RF and microwave laboratories,

More information

A DROP-IN REPLACEMENT SOLUTION FOR YOUR EMI / EMC COMPLIANCE PROBLEM

A DROP-IN REPLACEMENT SOLUTION FOR YOUR EMI / EMC COMPLIANCE PROBLEM 3HM57 Group R A DROP-IN REPLACEMENT SOLUTION FOR YOUR EMI / EMC COMPLIANCE PROBLEM The principle sources of the EMI problem come from the system clocks. Therefore, rather than patch the problem with ferrite

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Normative document: EN IS/IEC 17025:2005 Location(s) where activities are performed under accreditation Head ffice Vijzelmolenlaan 7 3447 GX oerden The Netherlands Location Abbreviation/ location Vijzelmolenlaan

More information

BENNING. CM7 Electrical Tester. Service Information

BENNING. CM7 Electrical Tester. Service Information BENNING CM7 Electrical Tester Service Information TABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specification

More information

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CNE III Comparison Noise Emitter Product Technical Information CNE III Comparison Noise Emitter The industry standard

More information

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz Compact designed and manufactured in compliance with CISPR 16-1, For Measurements

More information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating

More information

Analysis and Minimizing Strategies for Conducted Emission from Power Supply Cable of GPS Based Vehicle Tracking System

Analysis and Minimizing Strategies for Conducted Emission from Power Supply Cable of GPS Based Vehicle Tracking System Analysis and Minimizing Strategies for Conducted Emission from Power Supply Cable of GPS Based Vehicle Tracking System Shreenivas Jog and M. S. Sutaone Dept. of E and TC, College of Engineering, Pune,

More information

Spectrum Analyzer R&S FS300

Spectrum Analyzer R&S FS300 Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer

More information

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN) Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual Model 3725/2M Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

2.9GHz SPECTRUM ANALYZER

2.9GHz SPECTRUM ANALYZER 2.9GHz SPECTRUM ANALYZER Introducing a new 2.9GHz Spectrum Analyzer Manufacturing Research and Development Field Service Education Powerful capacity by advanced digital synthesizer Revolutionary features

More information

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer. Spectrum Analyzers 2394A 1 khz to 13.2 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements 1 khz to 13.2 GHz

More information

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro HIGH FREQUENCE HIGH VOLTAGE PROBE INSTRUCTION MANUAL For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro TABLE OF CONTENTS 1. SPECIFICATIONS 2. SAFETY PRECAUTIONS 3. OPERATION 4. COMPENSATION ADJUSTMENT

More information

Keeping Up with Safety & Compliance Sponsored by Power Integrations

Keeping Up with Safety & Compliance Sponsored by Power Integrations Keeping Up with Safety & Compliance Understanding LISNs Is Essential To EMI Pre-Compliance Testing by Kevin Parmenter, Chair, and James Spangler, Co-chair, PSMA Safety and Compliance Committee ISSUE: October

More information

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

More information

R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications R&S ZV-Z5x Calibration Units Specifications Test & Measurement Data Sheet 10.00 Specifications apply under the following conditions: Sufficient warm-up time (approx. 15 minutes) at ambient temperature,

More information

Vector Network Analyzers ZVB

Vector Network Analyzers ZVB Specifications Version 05.00 Vector Network Analyzers ZVB September 2005 Specifications MEASUREMENT RANGE...3 MEASUREMENT SPEED...5 MEASUREMENT ACCURACY...6 EFFECTIVE SYSTEM DATA...8 TEST PORT OUTPUT...8

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

Thruline RF Directional Wattmeters

Thruline RF Directional Wattmeters Portable Wattmeters BIRD S Famous ANALOG METER MODEL 43 Portable Wattmeter Power Range 100 mw - 10 kw using Bird Plug-in Elements.* Insertion VSWR with N Connectors 1.05 max. to 1000 MHz Finish Light Gray

More information

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE 69 CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE 4.1 INTRODUCTION EMI filter performance depends on the noise source impedance of the circuit and the noise load impedance at the test site. The noise

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

Trees, vegetation, buildings etc.

Trees, vegetation, buildings etc. EMC Measurements Test Site Locations Open Area (Field) Test Site Obstruction Free Trees, vegetation, buildings etc. Chamber or Screened Room Smaller Equipments Attenuate external fields (about 100dB) External

More information

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...

More information

2000 A DCA/ACA CLAMP + DMM,

2000 A DCA/ACA CLAMP + DMM, 2000 A DCA/ACA CLAMP + DMM, true rms DCA/ACA CLAMP METER Model : CM-9930 Your purchase of this DCA/ACA CLAMP METER marks a step forward for you into the field of precision measurement. Although this CLAMP

More information

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies 1 Definitions EMI = Electro Magnetic Interference EMC = Electro Magnetic Compatibility (No EMI) Three Components

More information

Fast Transient / Burst Simulator

Fast Transient / Burst Simulator EMC TESTS EQUIPMENTS CATALOGUE Fast Transient / Burst Simulator Reproduce showering arc at switching on/off of electric point of contact A simulator to reproduce fast repetitive frequency noises which

More information

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms True RMS AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms Caution Symbol Caution : * Risk of electric shock! Caution : * Do not apply the overload

More information

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release REVISION HISTORY The revision history for this document is shown in table. Version Issue Date Description HCT-EM-1801-FC037 January 22, 2018 Initial Release HCT-EM-1801-FC037-R1 January 26, 2018 Revision

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY EMI control is a complex design task that is highly dependent on many design elements. Like passive filters, active filters for conducted noise require careful

More information

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8)

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8) TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8) Equipment Under Test FRS / GMRS Model Name LXT600 FCC ID MMALXT600 IC Certification 3690A- LXT600 Applicant Midland Radio Corporation Manufacturer Global

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

FCC. RF Test Report. : Portable Bluetooth speaker : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013. Issue by

FCC. RF Test Report. : Portable Bluetooth speaker : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013. Issue by FCC RF Test Report Applicant Product Type Trade Name Model Number Test Specification : Harman International Industries, Incorporated : Portable Bluetooth speaker : JBL : CLIP2 AN : FCC 47 CFR PART 15 SUBPART

More information

Report No.: DREFCC CONTENTS. 1. General Remarks Test Laboratory General Information of EUT... 4

Report No.: DREFCC CONTENTS. 1. General Remarks Test Laboratory General Information of EUT... 4 CONTENTS 1. General Remarks... 3 2. Test Laboratory... 3 3. General Information of EUT... 4 4. EUT Operations and Test Configurations... 5 4.1 Principle of Configuration Selection... 5 4.2 EUT Operation

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Pen-type DIGITAL MULTITESTER

Pen-type DIGITAL MULTITESTER BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...

More information

A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference

A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference Progress In Electromagnetics Research Letters, Vol. 48, 75 81, 014 A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference Qiang Feng *, Cheng Liao,

More information

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800 IN ONE UNIT: 800W precision power amplifier, Spectrum Analyzer, Signal Generator General: The MTS-800 is a compact test system for broadband generation and measurement of magnetic fields. Its internal

More information

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO. Page 1 of 38 EMC Test Report PRODUCT DESIGNATION BRAND NAME MODEL NAME CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE

More information

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021 VCCI TEST REPORT According to V-3/2009.04, TECHNICAL REQUIREMENTS, Class B ITE Equipment : USB video camera Model No. : V-U0017 / V-U0021 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based

More information

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST... Table of Contents 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 4 1.2 RELATED SUBMITTAL(S) / GRANT (S)... 7 1.3 TEST METHODOLOGY... 7 1.4 EQUIPMENT MODIFICATIONS... 7

More information

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission 7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission 7.1 Test Setup Refer to the APPENDIX I. 7.2 Limit According to 15.247(d), in any 100 khz bandwidth outside the frequency band

More information

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz The Causes and Impact of EMI in Power Systems; Part Chris Swartz Agenda Welcome and thank you for attending. Today I hope I can provide a overall better understanding of the origin of conducted EMI in

More information

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual Broadband Current Probe Series Operation Manual 1 TABLE OF CONTENTS WARRANTY 3 INTRODUCTION 4 GENERAL INFORMATION 5 OPERATING INSTRUCTIONS 6 FORMULAS 7 MAINTENANCE 8 2 WARRANTY INFORMATION A.H. Systems

More information

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM MRI Shielding Environment

More information

GA GHz. Digital Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY

More information