Size: px
Start display at page:

Download ""

Transcription

1 1 of 6 03/12/ : HAMEG > Products > Accessories > Probes P R O B E S H Z * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Measurement range: ±30 A DC / 20 A AC Accuracy: ±1% ±2mA Frequency range: DC to 100 khz Resolution: 1 ma Output voltage: 100 mv/a Load impedance: > 100 kω Voltage stability: 3.7 kv / 50 Hz / 1 minute Connection: BNC-Cable, 2 m * Product discontinued; Successor: HZO50 H Z O 4 0 Differential Technical specifications at 23 C ±2 C 200MHz Rise time (10 90%): 1.75ns Gain accuracy ±1% Max. Input Voltage per Input: ±60V Max. Differential Input Voltage (DC + ±20V peak AC): Max. Common Mode Input Voltage: ±60V Input impedance Between Inputs: 1MΩ II 3.5pF Each Input to Ground: 500kΩ II 7pF Output Voltage (into 50Ω): ±2V Offset (typical) ±2mV CMRR (typical): -80dB at 60Hz -50dB at 10MHz Battery life (typical): 7.5h Input for an external power supply: USB Power adapter cable (5 9V DC /200mA) H Z O 4 1 Differential Probes 10:1 Professional articles Technical specifications at 23 C ±2 C 800MHz Rise time (10 90%): 437ps Gain accuracy ±2% Max. Input Voltage per Input: ±40V Max. Differential Input Voltage (DC + ±15V peak AC): Max. Common Mode Input Voltage: ±30V Input impedance Between Inputs: 200kΩ II 1pF Each Input to Ground: 100kΩ II 2pF Output Voltage (into 50Ω): ±1.5V Offset (typical) ±5mV

2 2 of 6 03/12/ :56 CMRR (typical): -60dB at 60Hz -15dB at 500MHz" Battery life (typical): 4.5h Input for an external power supply: USB Power adapter cable (5 9V DC /300mA) H Z O 5 0 AC/DC Current Probe 30A This AC/DC current probe is used to measure currents from 1mA to 30 A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Specifications Measurement range: Accuracy: Resolution: Output voltage: Load impedance: Max. Voltage: Output cable/connector: 2m (50Ω)/BNC II H Z O 5 1 ± 20 A rms /30A p ± 1% from measurement value ± 2mA DC 100 khz (0,5 db) ± 1mA 100mV/A 100 kω II 100 pf 300 V rms (AC or DC) AC/ DC Current Probe 100/ 1000A This AC/DC current probe is used to measure currents from 100mA to 1000A over a broad frequency range. The measurement principle is based on the Hall Effect that registers the magnetic field generated by the current flow. Even for complex waveforms a high degree of measurement accuracy is achieved. The output voltage is proportional to the measured current and well suited to be displayed on an oscilloscope. The current probe complies with the safety standards defined in IEC/EN Specifications Specifications Measurement range: Accuracy: Resolution: Output Voltage: Load impedance: Max. Voltage: Output cable/connector: 2m (50Ω)/BNC II H Z ±100A rms /1000A rms ±1% from measurement value ±0.1A/±0.5A DC 20kHz ±100mA/±500mA 10mV/A/1mV/A >100kΩ II 100pF 300V rms (AC or DC) 350MHz <1.0ns Input impedance: 10MΩ II 12pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer Cable length: 1.2m H Z MHz <700ps Input impedance: 10MΩ II 9.5pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer

3 3 of 6 03/12/ :56 Cable length: 1.3m Professional articles H Z MHz <1.4ns Input impedance: 10MΩ II 12pF Max. Voltage: 400V (DC + peak AC) RF compensation: 2 Trimmer Cable length: 1.2m H Z 5 1 Attenuation ratio 10:1 Bandwidth 150MHz Rise time <2.4ns Input impedance 10MΩ II 12pF Max. Voltage 600V (DC + peak AC) RF compensation: 1 Trimmer Cable length 1.2 m H Z 5 2 Attenuation ratio 10:1 Bandwidth 250MHz Rise time <1.4ns Input impedance 10MΩ II 10pF Max. Voltage 600V (DC + peak AC) LF compensation 1 Trimmer RF compensation 2 Trimmer Cable length 1.2 m H Z 5 3 Probe 100:1 Attenuation ratio 100:1 Bandwidth 100MHz Rise time <3.5ns Input impedance 100MΩ II 4.5pF Max. Voltage 1200V (DC + peak AC) LF compensation 1 Trimmer Cable length 1.2 m H Z Probe 1:1 / 10:1 Attenuation ratio 1:1 Switchable 10:1 Bandwidth 10/100MHz Rise time 35/3.5 ns Input impedance 1/10 MΩ II 82/12 pf Max. voltage (10:1) 600 V (DC + peak AC) LF compensation 1 Trimmer at 10:1

4 4 of 6 03/12/ :56 RF compensation 2 Trimmer at 10:1 Cable length 1.2 m H Z O 2 0 Probe 1000:1 Attenuation ratio: 1000:1 400MHz 900 ps Input impedance: 50 MΩ II 7.5 pf Max. Voltage: 1000 V rms RF compensation: 1 Trimmer Cable length: 1.3m I H Z O 3 0 Active 1GHz 600 ps Input impedance: 1MΩ II 0.9 pf Max. Input voltage: 20 V Input Dynamic Range: ± 8 V Cable length: 1.3m Oscilloscope Input Coupling: 50Ω External Power Supply included Professional articles H Z O MHz <1.4 ns Input impedance: 10 MΩ II 15 pf Max. Voltage: 400 V (DC + peak AC) RF compensation: 2 Trimmers Cable length: 1.2 m Probe factor identification: automatically after plugging

5 5 of 6 03/12/ :56 H Z Differential Probe 20:1 / 200:1 Technical specifications at 23 C ± 2 C Differential input voltage (DC + peak AC) ±700V max.: Max. input voltage per input: 600V rms Attenuation ratio: 20:1 Selectable: 200:1 30/40MHz 12/9ns Input impedance: 8MΩ II 1.2pF Output impedance: 50Ω Max. output Voltage: ±3.5V at 1MΩ Max. noise: 2mV Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 50cm with spring hooks Input for an external power supply: 12 14V dc /30mA H Z Differential Probe 1:1/ 10:1 Technical specifications at 23 C ± 2 C Differential input voltage (DC + peak AC) ±3,5V/35V max.: Max. input voltage per input: 100V rms Attenuation ratio: 1:1 Selectable: 10:1 30/40MHz 12/9ns Input impedance: 8MΩ II 1.2pF Output impedance: 50Ω Max. output Voltage: ±3.5V at 1MΩ Max. background noise at x1: <8mV rms at x10: <2mV rms Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 50cm with spring hooks Input for an external power supply: 12 14V dc /30mA

6 6 of 6 03/12/ :56 H Z Differential Probe 100:1/ 1000:1 Technical specifications at 23 C ± 2 C Differential input voltage (AC rms ): 1000V (DC + peak AC) max.: ±1400V*) Max. input voltage per input: ±1400V*) Attenuation ratio: 100:1 Selectable: 1000:1 20/30MHz 17/12ns Input impedance: 60MΩ II 1.5pF Output impedance: 50Ω Max. output Voltage: ±1.5V at 1MΩ Max. background noise: 2mV Accuracy after 1min: ±3% (18 30 C) Common mode rejection DC/AC 1MHz: 70dB/>50dB Inputs (CAT III): 2 safety connectors Input leads: 2 test leads 75cm with safety test clips Input for an external power supply: 12 14V dc /30mA *) due to test clip 1000 V CAT III 2012 HAMEG Instruments GmbH Last Updated

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

BumbleBee. High Voltage Differential Probe Ord.-No: Features: High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating

More information

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements High Voltage Differential Probe Order-No: 880-102-501 Features: 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating Temperatures (0 C to +50 C) High CMRR 4 Mode Attenuation Useable

More information

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2. TA041 25 MHz ±700 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING

More information

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe INSTRUCTION MANUAL TT-SI 9110 100MHz Active Differential Probe These probe is in compliance with EN61010-031:2002+A1:2008 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual:

More information

TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI 9001 / TT-SI MHz Active Differential Probes INSTRUCTION MANUAL TT-SI 9001 / TT-SI 9002 25MHz Active Differential Probes These probes are in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this

More information

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe INSTRUCTION MANUAL TT-SI 9101 100MHz Active Differential Probe These probe is in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual: WARNING.

More information

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2. TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING

More information

DC MHZ PXI Differential Instrumentation Amplifier

DC MHZ PXI Differential Instrumentation Amplifier DC - 100 MHZ PXI Differential Instrumentation Amplifier Differential 100 V Common Mode Input DC - 100 MHz Bandwidth AC/DC Coupling Programmable Attenuation/Gain/ Offset 9 nv/ Input Noise 50 Ω Output Impedance

More information

DataSheet SIGLENT Series Probe

DataSheet SIGLENT Series Probe DataSheet SIGLENT Series Probe Passive Probe Parameter PB470 PP510 PP215 PP430 Attenuation Rate 1 X/10 X 1 X/10 X 1 X/10 X 1 X/10 X Bandwidth 10 X: DC-70 MHz 10 X: DC-100 MHz 10 X: DC-200 MHz 10 X: DC-300

More information

E Series 9.00 (1/2) E series

E Series 9.00 (1/2) E series Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps

More information

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2. TA046 800 MHz ±30 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT I, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING Warning

More information

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

High Voltage Differential Probes HVD3605, HVD3206 HVD310x High Voltage Differential Probes HVD3605, HVD3206 HVD310x Key Features 1 kv, 2 kv, 6 kv CAT safety rated models World s only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015 Widest differential voltage

More information

TT-SI MHz DIFFERENTIAL PROBE

TT-SI MHz DIFFERENTIAL PROBE TT-SI 9110 100MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC - 1010. 2-031 CATⅢ, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual: WARNING.

More information

CX1100 Series Current and Differential Sensors

CX1100 Series Current and Differential Sensors DATA SHEET CX00 Series Current and Differential Sensors CX0A Current Sensor, Single Channel CX0A Current Sensor, Dual Channel CX03A Current Sensor, Low Side CX04A Current Sensor, Selectable Resistive Sensor

More information

Pre-Amplifier SPA Series

Pre-Amplifier SPA Series Pre-Amplifier SPA Series External Pre-Amplifier for all A/D cards Low noise/high gain Allows to acquire smallest signals with high resolution 5 different versions 20 db to 60 db gain up to 2 GHz bandwidth

More information

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro HIGH FREQUENCE HIGH VOLTAGE PROBE INSTRUCTION MANUAL For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro TABLE OF CONTENTS 1. SPECIFICATIONS 2. SAFETY PRECAUTIONS 3. OPERATION 4. COMPENSATION ADJUSTMENT

More information

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA Key Features 1 kv, 2 kv, 6 kv CAT safety rated models Widest differential voltage ranges available Exceptional common-mode rejection ratio (CMRR)

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation

More information

MD 200A High voltage differential probe

MD 200A High voltage differential probe 1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety

More information

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth

More information

Variable-Gain High Speed Current Amplifier

Variable-Gain High Speed Current Amplifier Features Transimpedance (gain) switchable from 1 x 10 2 to 1 x 10 8 V/A Bandwidth from DC up to 200 MHz Upper cut-off frequency switchable to 1 MHz, 10 MHz or full bandwidth Switchable AC/DC coupling Adjustable

More information

Oscilloscope Probes and Accessories

Oscilloscope Probes and Accessories Oscilloscope Probes and Accessories Pomona s oscilloscope probes give you the full range you need. Designed, rated, and specified to match the bandwidth of your instrument, they provide you with full voltage

More information

AC/DC current clamps (1/2) E N series

AC/DC current clamps (1/2) E N series AC/DC current clamps The clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. These clamps' narrow, elongated design makes them ideal areas

More information

10.00 (1/2) PAC series

10.00 (1/2) PAC series Clamp-on AC/DC current probes PAC Series The is a range of professional AC/DC clamp-on current probes designed to meet the very latest in safety and performance standards. There are two different jaw designs

More information

1587/1577 Insulation Multimeters

1587/1577 Insulation Multimeters 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Current clamps for AC current

Current clamps for AC current Current clamps for AC current Y series The Y series clamps are designed to be both rugged and versatile whilst remaining easy to use. The jaws are designed so that the clamps can be hooked onto cables

More information

9 Specifications. Specifications NOMINAL CHARACTERISTICS

9 Specifications. Specifications NOMINAL CHARACTERISTICS 9 Specifications Specifications NOMINAL CHARACTERISTICS WARRANTED CHARACTERISTICS Nominal characteristics describe parameters and attributes that are guaranteed by design, but do not have associated tolerances.

More information

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide Introduction To achieve the best results from

More information

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth

More information

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources. 3 Channel Digital Storage Oscilloscope (DSO) Instrument VERTICAL SPECIFICATIONS Analogue Bandwidth (-3dB) Bandwidth Limiting Rise time (10% to 90%, calculated) Input ranges (full scale) Input sensitivity

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP ON PROBE 327 series AC/DC CURRENT SENSOR CT686 series 99 Washington Street Melrose, MA 2176 Phone 781-665-14 Toll Free 1-8-517-8431 Visit us at www.testequipmentdepot.com Wide-band Models from DC

More information

Variable-Gain High Speed Current Amplifier

Variable-Gain High Speed Current Amplifier Features Transimpedance (Gain) Switchable from 1 x 10 2 to 1 x 10 8 V/A Bandwidth from DC up to 200 MHz Upper Cut-Off Frequency Switchable to 1 MHz, 10 MHz or Full Bandwidth Switchable AC/DC Coupling Adjustable

More information

PRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES

PRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES 50MHz bandwidth Battery powered, connects to any oscilloscope via BNC Standby feature for low power consumption ± 25V measuring range Excellent

More information

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip Certificate of Calibration available on request Read-out BNC Connector

More information

Probes and Accessories

Probes and Accessories 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Probes and Accessories Your Guide to Selecting the Right Probe Measurement Accuracy

More information

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments High impedance passive probe Features: CeramCore TM hybrid probe Modular construction Coaxial design Interchangeable spring contact tip Certificate of calibration available on request Read-out BNC connector

More information

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories For 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide 02 Keysight InfiniiVision Oscilloscope

More information

Specifications for DS1000CA Series

Specifications for DS1000CA Series Revised December, 2009 RIGOL Specifications for DS1000CA Series All specifications apply to the DS1000CA Series Oscilloscopes unless noted otherwise. To meet these specifications, two conditions must first

More information

Flexible AC current probes

Flexible AC current probes Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current

More information

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes Data Sheet Introduction The Keysight Technologies, Inc. N2792A/93A and N2818A/19A differential probes provide the

More information

Variable Gain 100 MHz Wideband Voltage Amplifier

Variable Gain 100 MHz Wideband Voltage Amplifier Features 10 to 60 db, Switchable in 10 db Steps Bandwidth DC... 100 MHz, Switchable to 10 MHz Built-In Temperature Compensation for Low Drift of 0.6 µv/k 2.5 nv/ Hz Input Noise Switchable AC/DC-Coupling

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available

More information

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1] www.analogarts.com Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, and an arbitrary

More information

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series Quick Start RSDPB5000/RSDPB4000 High Voltage Differential Probe Series 2 Please read this manual carefully before use Safety precautions 1. Be cautious of an electric shock 2. Pay attention to the maximum

More information

DS 6000 Specifications

DS 6000 Specifications DS 6000 Specifications All the specifications are guaranteed except the parameters marked with Typical and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.

More information

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A The CPCO Series (160mm aperture) Current Probes are Clamp On current sensors capable of measuring ac and dc currents. The Current Probe splits along a diameter allowing easy installation to existing cables

More information

Agilent Technologies 5000, 6000 and 7000 Series InfiniiVision Oscilloscope Probes and Accessories

Agilent Technologies 5000, 6000 and 7000 Series InfiniiVision Oscilloscope Probes and Accessories 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Agilent N2772A Product Page Agilent Technologies 5000, 6000 and 7000

More information

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A, The CPCO Series (160mm) Current Probes are Clamp On current sensors capable of measuring ac and dc currents available in ranges of ±4000A ±8000A, ±12000A with an accuracy of +/-1% and non-linearity of

More information

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide User s Guide Publication Number E2695-92000 June 2003 Copyright Agilent Technologies 2003 All Rights Reserved. Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes Agilent

More information

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1] www.analogarts.com Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, an arbitrary

More information

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. Pinces Current ampèremetriques clamps for AC/DC pour current courant AC SERIE E N The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over

More information

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave. 20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer

More information

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,

More information

400 MHz Passive High-Voltage Probe R&S RT-ZH

400 MHz Passive High-Voltage Probe R&S RT-ZH Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit

More information

200 MHz Variable Gain Photoreceiver

200 MHz Variable Gain Photoreceiver The image shows model -FST with 1.035-40 threaded flange and coupler ring. Features Applications Adjustable transimpedance gain from 10 2 to 10 8 V/A Wide bandwidth up to 200 MHz Si-PIN photodiode covering

More information

Variable Gain Low Frequency Voltage Amplifier

Variable Gain Low Frequency Voltage Amplifier Features Applications 20 to 80 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 1 kω Single Ended and True Differential Input Models Bandwidth DC -

More information

World-Class Accuracy & Measurement Range (40 Conventional Models)

World-Class Accuracy & Measurement Range (40 Conventional Models) AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)

More information

Data sheet IDM 99III Digital Multimeter

Data sheet IDM 99III Digital Multimeter RS Stock No. 7575116 Data sheet IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic DCV accuracy

More information

Analog Arts SF990 SF880 SF830 Product Specifications

Analog Arts SF990 SF880 SF830 Product Specifications 1 www.analogarts.com Analog Arts SF990 SF880 SF830 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without

More information

Tablet Oscilloscope Data Sheet

Tablet Oscilloscope Data Sheet Tablet Oscilloscope Data Sheet For tbook Series 2015.1 Shenzhen Micsig Instruments Co., Ltd. Model TO102 TO102A TO104 TO104A TO152 TO152A Channels 2 2 4 4 2 2 Bandwidth 100M 100M 100M 100M 150M 150M Risetime

More information

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3249 RS PRO IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic

More information

Analog Arts SF900 SF650 SF610 Product Specifications

Analog Arts SF900 SF650 SF610 Product Specifications www.analogarts.com Analog Arts SF900 SF650 SF610 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without prior

More information

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 INSTRUCTION MANUAL General Safety Instructions: Read the following safety instructions to avoid injury and prevent damage to this product

More information

1507/1503. Insulation Testers. Technical Data. Features and benefits:

1507/1503. Insulation Testers. Technical Data. Features and benefits: 1507/1503 Insulation Testers Technical Data The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting,

More information

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design High impedance passive probe Features: CeramCore TM hybrid probe Modular construction Coaxial design Interchangeable spring contact tip Certificate of calibration available on request Read-out BNC connector

More information

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet 02 Keysight N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

More information

DSO 3000 Series Oscilloscope

DSO 3000 Series Oscilloscope Key Features 200 / 100 / 70MHz bandwidths Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger 1GSa/s Real Time sample rate 7 large color display, WVGA (800x480) 2 Channels,

More information

Variable Gain Photoreceiver - Fast Optical Power Meter

Variable Gain Photoreceiver - Fast Optical Power Meter The picture shows model -FC with fiber optic input. Features Conversion gain switchable from 1 x 10 3 to 1 x 10 11 V/W InGaAs-PIN detector Spectral range 900-1700 nm Calibrated at 1550 nm (fiber optic

More information

S5101 Handheld Radio Communication Analyzer

S5101 Handheld Radio Communication Analyzer is the ideal radio tester for laboratory, production, service and maintenance use. It combines radio frequency emission, reception analysis, audio source, analyzer, etc. all into one unit. It can measure

More information

Specification for Conducted Emission Test

Specification for Conducted Emission Test 1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5

More information

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc User s Guide RP1000D Series High Voltage Differential Probe Feb. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2012 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

More information

Data sheet IDM 98III Digital Multimeter

Data sheet IDM 98III Digital Multimeter RS Stock No. 7575110 Data sheet IDM 98III Digital Multimeter FEATURE: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic DCV accuracy

More information

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer Application Note Introduction This note details the input impedance of the U8903B Audio Analyzer, and shows that this needs to

More information

AP034-OM-E Rev D ISSUED: January 2000 ²

AP034-OM-E Rev D ISSUED: January 2000 ² 3HUIRUPDQFH9HULILFDWLRQ 3HUIRUPDQFH9HULILFDWLRQ This procedure can be used to verify the warranted characteristics of the AP034 Active Differential Probe. The recommended calibration interval for the model

More information

Infiniium Series Oscilloscope Probes, Accessories, and Options

Infiniium Series Oscilloscope Probes, Accessories, and Options 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Agilent 1153A Product Info Page Infiniium Series Oscilloscope Probes,

More information

Dual operational amplifier

Dual operational amplifier DESCRIPTION The 77 is a pair of high-performance monolithic operational amplifiers constructed on a single silicon chip. High common-mode voltage range and absence of latch-up make the 77 ideal for use

More information

PRODUCTS PINTEK. Pintek Electronics Co., Ltd Condensed Catalog.

PRODUCTS PINTEK. Pintek Electronics Co., Ltd Condensed Catalog. PRODUCTS Pintek Electronics Co., Ltd 2016-17 Condensed Catalog www.pintek.com.tw TABLE OF CONTENTS Differential Probe Current Probe High Voltage Amplifier LCR Meter DC Power Supply Milli-OHM Meter Programable

More information

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3248 RS PRO IDM 98III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic

More information

Agilent IniniiVision Oscilloscope Probes and Accessories

Agilent IniniiVision Oscilloscope Probes and Accessories Agilent IniniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series Selection Guide Data Sheet To achieve the best results from your scope, you

More information

HA-2520, HA-2522, HA-2525

HA-2520, HA-2522, HA-2525 HA-, HA-, HA- Data Sheet September 99 File Number 9. MHz, High Slew Rate, Uncompensated, High Input Impedance, Operational Amplifiers HA-// comprise a series of operational amplifiers delivering an unsurpassed

More information

Probing for oscilloscope

Probing for oscilloscope Probing for oscilloscope Agenda - Notion de sonde en oscilloscopie - Structure des différentes sondes - Passives - Actives - Logiques - Différentielles - Comment choisir la bonne sonde - Nouvelle technologie

More information

AC Current Probes CT1 CT2 CT6 Data Sheet

AC Current Probes CT1 CT2 CT6 Data Sheet View at www.testequipmentdepot.com AC Current Probes CT1 CT2 CT6 Data Sheet Features & Benefits High Bandwidth Ultra-low Inductance Very Small Form Factor Characterize Current Waveforms up to

More information

Chapter 6 Specifications

Chapter 6 Specifications RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,

More information

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications FUNCTION GENERATOR EAN CODE : 3760244880468 5 MHZ+RS232++(USB or LAN)* GF 467F COMPLETE : Reciprocal frequency counter 50 MHz. - Internal linear or logarithmic sweep, and external VCF or FM modulation.

More information

Schlöder GmbH - EMC Test and Measurement Systems Model #

Schlöder GmbH - EMC Test and Measurement Systems Model # Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD

More information

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.8 to 1.27 mm pitch Unbreakable Reed Switch

More information

Voltage Sensors URV5-Z

Voltage Sensors URV5-Z Data sheet Version 05.00 Voltage Sensors URV5-Z May 2005 Universal voltage measurements from RF to microwaves The voltage sensors of the URV5-Z series are indispensable tools in RF and microwave laboratories,

More information

Simple measurement at the best price

Simple measurement at the best price Simple measurement at the best price n Multimeters n Clamp-on multimeters n Electrical safety testers n Testers n Environmental measurements n Laboratory instruments 01/2018 CONTENTS Multimeters page 3

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product

More information

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet Agilent U2701A and U2702A USB Modular Oscilloscope Data Sheet Features 100 MHz and 200 MHz bandwidths Up to 1GSa/s maximum sample rate 32 Mpts of waveform memory Compact and portable size 117.00 mm x 180.00

More information

Fluke 192/196/199. ScopeMeter. Users Manual

Fluke 192/196/199. ScopeMeter. Users Manual Fluke 192/196/199 ScopeMeter Users Manual 4822 872 00983 October 2000, Rev.2, 2/01 2000 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks of their respective

More information

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III HZ 115 Differential probe for oscilloscopes 1500 V input voltage max. 30 MHz bandwidth x 100 and x 1000 attenuation 50 db CMRR (1MHz) User-friendliness through a microcontroller Automatic Switch-off Beep

More information

InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-,

InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-, InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-, 4000 X-, 5000, 6000, and 7000 Series Selection Guide Data Sheet To achieve the best results from your scope, you need the right probes

More information

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR 5MHz FUNCTION GENERATOR MODEL GF-8056 User s Manual Elenco TM Electronics, Inc. Copyright 2004 by Elenco TM Electronics, Inc. All rights reserved. 753117 No part of this book shall be reproduced by any

More information

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR 5MHz FUNCTION GENERATOR MODEL GF-8056 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com User s Manual Elenco TM Electronics, Inc.

More information

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument Tunable Active Single Channel Certified Filter Instrument Description Frequency Devices instruments are single channel; 8-pole low-pass or high-pass, front panel tunable filter instruments. The controls

More information

Variable Gain Photoreceiver Fast Optical Power Meter

Variable Gain Photoreceiver Fast Optical Power Meter The picture shows model -FC with fiber optic input. Features Si-PIN detector, active area 1.1 x 1.1 mm 2 Spectral range 190-1000 nm Very low noise, NEP down to 17 fw/ Hz Bandwidth up to 500 khz Conversion

More information

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.8 to 1.27 mm pitch The PMT 211A-RO is a 250

More information

Measurement and Analysis for Switchmode Power Design

Measurement and Analysis for Switchmode Power Design Measurement and Analysis for Switchmode Power Design Switched Mode Power Supply Measurements AC Input Power measurements Safe operating area Harmonics and compliance Efficiency Switching Transistor Losses

More information

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management

More information