1 DI T ID S DT ST This DI gas analyzer is used for measuring CO, CO, SO and C 4 and features a high accuracy, multiple functions and easy operation through use of a microprocessor. It is housed in a 19 inch rack case suitable for mounting on a panel or a table-top. The analyzer provides a performance superior to the conventional double-beam system, is easy to maintain, and offers an excellent long-term stability. It is thus optimum for continuous measurement in the combustion control of various industrial furnaces, in research on garden-plants, and so on. TS 1. The use of a microprocessor provides high accuracy, multiple functions and easy operation. ero and span calibration is accurate and easy just by pressing the calibrating keys. self-diagnosis function is included. n automatic calibrating function can be provided as an option. ange can be changed over by a external signal as an option.. n improved optical system provides long term stability, and there is a minimum of drift caused by contamination of the measuring cell, so the long-term stability is excellent. 3. dopting a serial dual-layer type of transmission detector minimizes remarkable the interface from other gas components. 4. asy maintenance. The single-beam photometric system uses a sample cell only and eliminates the necessity of delicate adjustment for optical balance. The instrument is designed as a unit of simple construction featuring easy maintenance and checks. SCIICTIOS easurable gas components: Single-component CO CO, SO, C 4 : Dual-component CO /CO: andfill garbage application CO : C 4 : 0 to 80% easuring range: efer to measurable range combination table (page 5). easuring system: on-dispersion infrared-ray absorption method, deviation method, single light source single beam Output signal: Output 1; 0 to 1V DC Output ; 4 to 0m DC (optional allowable load resistance 550Ω or less). epeatability: 1st range (low range) Within ± 0.5% of full scale nd range (high range) Within ± 1% of full scale inearity: ± % of full scale ero drift: Within ± % of full scale/week Span drift: Within ± % of full scale/week esponse time: Within 15 seconds max. (for 90% response) depending on cell length ower supply: 100V, 115V, 0V or 40V ±10% C, 50/ 60z ower consumption: 3V max. DS3-111c Date Oct. 10, 1998

2 mbient temperature: 5 to +45 C mbient humidity: 90% or less nclosure: Steel casing, for indoor use Storage condition: Temperature; 0 to +60 C umidity; 100% max. (free from condensation) Outer dimensions ( x W x D): ack mounting type; 133 x 483 x 435 mm anel flush mounting type; 133 x 443 x 435 mm Table-top type; ass weight: pprox. 1g inish color: unsell.58.4/1. Display: 4 digit D for concentration display 4 digit D for sub-display Output hold: Output value before manual or automatic calibration is hold. Whether or not to effect hold function can be selected. Sample gas condition: Temperature; 0 to 50 C Dust; less than 0.3 µm ressure; less than 9.8 ka Standard adjustment gas: Dry alance Warm up time: pprox. hours aterial of gas-ing parts: Sample cell, SS304, neoprene rubber Infrared-ray transmitting window; Ca or sapphire Internal tubing; Toaron tube as inlet/outlet, purge gas inlet size: c1/4 (T1/4 internal thread) or T1/4 internal thread easured gas flow rate: 1 ± 0.5 liter/minutes urge gas flow rate: pprox. 1 liter/minute Scope of delivery:nalyzer, power fuse, manual, mounting bracket in the case of panel mounting type ounting method: ounted on 19 inch rack, or on panel, or on table-top approx. 50mm 90 Support Optional specifications emote hold: nalog (DC0-1V, 4-0m) is held via external signal. Input signal: 5V DC emote range changeover: ange is changeable via external signal. ange changeover input signal: 5V DC ange identification signal : Contact ; 1 a Contact capacity; 50V C, (resistive load) utomatic calibration: ero and span are automatically calibrated at the preset cycle. Calibration gas is supplied sequentially by driving an electromagnetic value installed outside. Calibration channel: p to components can be calibrated simultaneously. ero calibration point: ixed at 0% Span calibration point: 5 full scale Calibration start: Via built-in timer or remote start signal Output hold at calibration: ossible Calibration gas flow mode: (1) ero gas () ero gas span gas 1 (3) ero gas span gas (4) ero gas span gas 1 span gas Calibration gas flow time: Settable from 100 to 599 sec. Calibration cycle: 1 to 199 hours (in 1-hour step) Calibration failure alarm: rovided when fault occurs during auto calibration. Contact : During calibration; 1 a (.O), capacity 50V C, (resistive load) Calibration failure; 1 a (.O), capacity 50V C, (resistive load) lectromagnetic valve drive; 1 a (.O), capacity 50V C, (resistive load) emote start: emote start signal; voltage input 5V DC emark: 0% or more of the analyzer weight should be supported at the bottom of the case. (In case of mounting panel or 19 inch rack, provide a support at the rear of casing.) Installation conditions: Install the analyzer at a place not exposed to direct sunlight or the radiation from a high temperature object. void vibration, and select a clean place free of corrosive and/or combustible gases. If installing outdoors, provide a suitable casing or cover to protect the analyzer from wind, rain, etc.

3 COD SOS (1) Single-component analyzer Description 1 o. of measurable components Single component D easurable component SO CO CO C4 Q W X easuring range (1st range) (ote 1) 0 to 500 ppm 0 to 500 ppm 0 to 3% 0 to 40% 0 to 0% ower supply, iping connection 100V C 50z c 1/4 100V C 60z c 1/4 115V C 60z c 1/4 0V C 50z c 1/4 100V C 50z T 1/4 100V C 60z T 1/4 115V C 60z T 1/4 0V C 50z T 1/4 40V C 50z T 1/4 40V C 50z c 1/4 C Structure Table top type 19 inch rack mounting type anel mounting type Output signal (Output 1/) (otes, 3) 0 to 1V DC /4 to 0m DC Optional function (1) one With auto-calibration Optional function () one With remote range, range identification and remote hold easuring range (nd range) (ote 1) one 0 to 500 ppm djustment gas Standard for carburizing furnace (ote 4) aint uji standard on standard specifications on standard otes : (1) efer to measurable range combined table () Output signal are provided simultaneously (3) 0 to 100mV, 0 to 10mV DC is available on request (4) To be adviced components of sample gas 3

4 () Dual-component analyzer V C Description o. of measurable components Dual component easurable component CO/CO easuring range (1st comp. 1st range) ote (5, 6) easuring range (nd comp. 1st range) ote (5, 6) 0 to 500 ppm 0 to 5% ower supply, iping connection 100V C 50z c 1/4 100V C 60z c 1/4 115V C 60z c 1/4 0V C 50z c 1/4 100V C 50z T 1/4 100V C 60z T 1/4 115V C 60z T 1/4 0V C 50z T 1/4 40V C 50z T 1/4 40V C 50z c 1/4 Structure Table top type 19 inch rack mounting type anel mounting type Output signal (Output 1/) (otes, 3) 0 to 1V/DC 4 to 0m DC Optional function (1) one With auto-calibration Optional function () one With remote range, range identification and remote hold The product conforms to the requirements of the lectromagnetic compatibility Directive 89/336/C as detailed within the technical construction file number T3456. The applicable standards used to demonstrate compliance are : : 1991 CSS Conducted and adiated emissions : 199 V Description easuring range (1st comp. nd range) one easuring range (nd comp. nd range) one 0 to 5% djustment gas Standard for carburizing furnace aint uji standard on standard specifications on standard adiated immunity, SD and T ote (5) efer to measurable range combination table (6) 1st comp. is CO, nd comp. is CO. 4

5 easurable range combination table (1) Single-component (CO CO C 4 ) nd range 1st range Q W X 0 to 500 ppm 0 to 500 ppm 0 to 3% 0 to 40% 0 to 0% :CO :CO : C 4 :SO : Impossible * lso single range is possible 0 to 500 ppm () Dual-components (CO /CO) nd component 1st range 1st component 1st range CO 0 to 500ppm 0 to 1000ppm 0 to 000ppm 0 to 5000ppm CO V 0 to 5% 1st component is CO, nd component is CO. : Dual-components are possible oth components are able to have nd range. nd range is x or x.5 of 1st range, choose the Code symbols * : Dual-components are possible ut only one component, CO or CO, is able to have nd range. nd range is x or x.5 of 1st range, choose the Code Symbols. : Impossible. * DT ICI DI Infrared ray light source as inlet as outlet Detector Synchronuous motor easuring cell ass flow sensor otary sector DC amplifier ectifier C amplifier C /D Input emote range emote hold Contact D/ Output 0 to 1V, 4 to 0m DC Operating panel ange identification signal Output during calibration Display Operation key 5

6 OTI DI (nit:mm) ower switch Operating panel (ack mounting plate) anel cutout dimensions (in case of panel mounting) <ront View> xternal connection terminal (1st component) <Side View> Sample gas inlet (c 1/4 or T 1/4) Sample gas outlet (c 1/4 or T 1/4) urge gas inlet (c 1/4 or T 1/4) (nd component) (TO C) 435 ower terminals COCTIO DI Output 1: 0 to 1V DC Output : 4 to 0m DC ault <ear View> 1st component nd component TO C ange nder (option) Output 1: ange 1 identification 1 calibration 0 to 1V DC identification (option) Output : 3 9 (option) uto to 0m DC calibration failure 4 10 emote hold 5 11 input(option) emote range 6 1 emote range emote 6 1 input(option) input(option) start input ero gas Span gas 1 Span gas SCO O DIV 1 x gas analyzer main unit 1 x test report 1 x instruction manual x ower fuse 4 x panel mounting bracket TD DVICS as sampling device ccommodating locker Standard gas (for calibration) eceiving instrument ODI IOTIO 1. nalyzer type.. aximum, normal and minimum concentrations of sample gas as well as type and content (percent by volume) of concomitant gas. 3. Temperatures (maximum, normal and minimum), pressure and humidity of sample gas. 4. Dust conditions (mg/m 3 or particle size, characteristics, etc.) and environmental conditions. 5. Other items ead office 11- Osaki 1-chome, Shinagawa-ku, Tokyo, apan hone: Sales Div. International Sales Dept. o.1, uji-machi, ino-city, Tokyo, apan hone: , 60 ax: , 6189 Information in this catalog is subject to change without notice. rinted in apan

MICROPROCESSOR BASED NDIR GAS ANALYZER ZRF

MICROPROCESSOR BASED NDIR GAS ANALYZER ZRF T ST IROROSSOR S IR S R R This IR gas analyzer features a high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high

More information

General Specifications

General Specifications General Specifications GS G00-0 I400 DI TYP IFAD GAS AALYZ (5-POT AALYZ) The I400 infrared gas analyzer is capable of measuring the concentrations of,,,, C4 and components in sample gas.,,, and C4 are

More information

INFRARED GAS ANALYZER

INFRARED GAS ANALYZER INFRRED GS NLYZER DT SHEET ZRE This gas (ZRE) is capable of measuring the concentration of NO,SO2,CO2,CO,CH4 and O2 components in sample gas. NO,SO2,CO2,CO and CH4 are measured by non-dispersion infrared

More information

1/16 DIN (48 48 mm) temperature controller PXR

1/16 DIN (48 48 mm) temperature controller PXR / DIN (8 8 mm) temperature controller PXR Features Large LED display and front waterproof structure Easy-to-see, large LED display (. times larger than current models) Easy-to-wire screw terminal design

More information

Online data sheet GMS800 EXTRACTIVE GAS ANALYZERS

Online data sheet GMS800 EXTRACTIVE GAS ANALYZERS Online data sheet GMS800 F H I J K L M N O P Q R S T 14181 certified US 15267 certified Ordering information Type GMS800 Part no. On request The exact device specifications and performance data of the

More information

Online data sheet GM35 IN-SITU GAS ANALYZERS

Online data sheet GM35 IN-SITU GAS ANALYZERS Online data sheet GM35 C D E F Ordering information Type GM35 Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and

More information

HA930 HA430. General Description. Features. Resin Pressure Digital Controller HA930/430. Easy zero and span adjustments

HA930 HA430. General Description. Features. Resin Pressure Digital Controller HA930/430. Easy zero and span adjustments /M /L /S /M /L /S /M /L /S P CPU esin Pressure Digital Controller H90/0 H90 H0 General Description The H90/0 Series strain gauge input make it ideal for melt pressure control. Featuring high speed sampling

More information

General Specifications

General Specifications General Specifications IR400 Infrared Gas Analyzer [Style : S4] The IR400 infrared gas analyzer is capable of measuring the concentrations of O, SO 2, CO 2, CO, CH 4 and O 2 components in sample gas. O,

More information

General Specifications

General Specifications General Specifications GS 11G001-01 IR400 DIR TYP IFRARD GAS AALYZR (5-MPOT AALYZR) The IR400 infrared gas analyzer is capable of measuring the concentrations of O, SO,,, C4 and O components in sample

More information

INFRARED GAS ANALYZER

INFRARED GAS ANALYZER INFRRED GS NLYZER DT SHEET ZRE This gas analyzer (ZRE) is capable of measuring the concentration of NO,SO,O,O,H and O components in sample gas. NO,SO,O,O and H are measured by non-dispersion infrared method

More information

CROSS STACK LASER GAS ANALYZER

CROSS STACK LASER GAS ANALYZER DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of HCl contained in fl ue gas in waste incineration plants and

More information

CRoSS StACK LASeR gas ANALYZeR

CRoSS StACK LASeR gas ANALYZeR DATA SHEET CRoSS StACK LASeR gas ANALYZeR (Dual beam version) Cross stack laser gas analyzer (ZSS) provides continuous measurement of CO and O2 gas concentration with fast response. Since ZSS is installed

More information

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control SX General Description The SX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control can be performed with a single compact

More information

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS PRODUCT DATASHEET - APPLICATIONS Indoor air quality studies Workplace exposure measurements Exhaust air monitoring Emission source classification BENEFITS Continuous and simultaneous real-time measurements

More information

1 Overview. Continuous Gas Analyzers, extractive SIPROCESS UV600

1 Overview. Continuous Gas Analyzers, extractive SIPROCESS UV600 Overview The function of the gas analyzer is based on UV resonance absorption spectrometry. It also is used to measure very low NO, NO 2, SO 2 or H 2 S concentrations in gases. Benefits For NO, NO 2, SO

More information

BATAILG TAIL GAS ANALYZER. Rev. 1.1

BATAILG TAIL GAS ANALYZER. Rev. 1.1 BATAILG TAIL GAS ANALYZER Rev. 1.1 The Tail Gas Analyzer is part of the BAGGI BASE Instruments Series. They are the result of combining the latest state-of-the-art-technology with over 60 years of industry

More information

CROSS STACK LASER GAS ANALYZER

CROSS STACK LASER GAS ANALYZER DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of density of HCl contained in fl ue gas in waste incineration

More information

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1) /M R/L R/S /M R/L R/S /M R/L R/S P CPU Resin Pressure Digital Controller H90 H90 General Description The H90 strain gauge make it ideal for melt pressure control. Featuring high speed sampling and control

More information

Model LS 250 Loop Scanner Operator s Manual. Version

Model LS 250 Loop Scanner Operator s Manual. Version Model LS 250 Loop Scanner Operator s Manual Version 05-2011 Contents 1. Introduction...2 2. Description...3 2.1 Model Nomenclature...3 2.2 Operating Principle...3 2.3 Specifications...5 3. Location and

More information

FW100 Dust Measurement Device

FW100 Dust Measurement Device product InForMAtIon FW100 Dust Measurement Device Preventing fine dust polluting the air by using scattered-light technology Analyzers and Process Instrumentation FW100 using Scattered Light Technology

More information

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C T Series nalog nd Non-Indicating Type, PID Control, Set y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control

More information

S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS

S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS 2 AERECO Sensor range INDOOR AIR QUALITY, A QUESTION OF BALANCE Most of the new

More information

eye in hell CD 3002 Sensor Manual

eye in hell CD 3002 Sensor Manual Your eye in hell CD 3002 Sensor Manual Siemens Laser Analytics AB Oct 2001 CD 3002 Sensor manual Document number: CID 3002-1102 Rev. 2A LDS 3000 Sensor manual Content Content 1. CD 3002 1 1.1 General 1

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780

More information

Digital Fiber-Optic Switches

Digital Fiber-Optic Switches CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the

More information

General Specifications

General Specifications General Specifications IR202 Infrared Gas Analyzer GS 11G02Q02-01EN GENERAL The IR202 infrared gas analyzer is capable of measuring concentration of CO 2, CO, CH 4, SO 2, and NO components in sample gas

More information

OD Max: Highly precise distance measurement

OD Max: Highly precise distance measurement OD Max: Highly precise distance measurement thickness or the evenness can be achieved. This is due to the in the system integrated arithmetical functions. D T SHEET Displacement TThe OD Max is an highly

More information

MICRO-CONTROLLER X (48mm 48mm)

MICRO-CONTROLLER X (48mm 48mm) PX series Digital temperature Controller DT SHEET Socket Type With front dimensions of 8 8mm, this socket type temperature controller enables OnOff control, PID control or 8step ramp/soak function, using

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web S-CO2 CO 2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH TF5701_B_v1_web 1 DESCRIPTION This module measures carbon dioxide (CO 2 ) in the range of 0 to 2 000 ppm and is equipped with

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems Customized HP00 Sensors HP00 Series Customized to solve difficult application problems The HP00 Series: Are you faced with any of these problems? Tightly mounted thru-scan sensors interfere with each other,

More information

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes

More information

xentra 4900 Continuous Emissions Analyser

xentra 4900 Continuous Emissions Analyser xentra 4900 Continuous Emissions Analyser The xentra 4900 is a cost effective, high performance solution for Continuous Emission Monitoring applications Low cost of ownership Multiple gas capability (O

More information

Ramp/Soak Temperature Controller REX-P250

Ramp/Soak Temperature Controller REX-P250 EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern

More information

QPM Series Indoor Air Quality Duct Sensors

QPM Series Indoor Air Quality Duct Sensors Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50 HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50 BAROMETRIC PRESSURE TRANSMITTERS - STATIC PORT FOR BAROMETRIC MEASUREMENTS GENERAL DESCRIPTION HD 9408T BARO, HD 9408TR BARO and HD 9908T BARO

More information

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS MTS AND MTS PR¼ 16 OUTPUT PENTAIR CLEAN AIR SYSTEMS MTS DESCRIPTION The Model MTS sequencer has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing

More information

Differential pressure sensors

Differential pressure sensors 1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root

More information

Ensure reliable and repeatable multi-component gas analysis.

Ensure reliable and repeatable multi-component gas analysis. Ensure reliable and repeatable multi-component gas analysis. Rosemount X-STREAM Enhanced Continuous Gas Analyzers Realize significant costs savings with flexible and accurate multi-component, multi-method

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in: oxy.iq Panametrics Oxygen Transmitter Applications An oxygen transmitter for use in: Glove box purge and leak detection Natural gas Semiconductor wafer machines Coating process machines Membrane air separators

More information

Microprocessor-based Temperature Controller

Microprocessor-based Temperature Controller R 1100 The Temperature Controller Heat-only Controller Heating-off-Cooling Controller DIN-Format: 96 x 96 mm Installation depth: 67 mm Microprocessor-based Temperature Controller Description And Operating

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

(Rev. 02 of ) EN English. ASSEMBLAD S.r.l Campi Bisenzio Firenze Italy

(Rev. 02 of ) EN English. ASSEMBLAD S.r.l Campi Bisenzio Firenze Italy (Rev. 02 of 05.2014) EN English INFRA-QUEEN BENCH OIML R99-2008 Class 00 Cell in Class 00 for exhaust gas analysis The new cell of gas analysis Infra-00 currently represents an evolution of that one in

More information

General Specifications

General Specifications General Specifications IR202 Infrared Gas Analyzer GS 11G02Q02-01EN GENERAL The IR202 infrared gas analyzer is capable of measuring concentration of CO 2, CO, CH 4, SO 2, and NO components in sample gas

More information

HA400 HA900 HA401 HA901

HA400 HA900 HA401 HA901 A/ R/L R/S High-Speed Digital Controller - or loops HA Series HA00 HA900 HA0 HA90 General Description he HA series are digital PID controllers with a high speed sampling time of ms (0.0 sec) with high-resolution

More information

Amer Technical Information TI 312e00 Solids Content Sensor SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Abso

Amer Technical Information TI 312e00 Solids Content Sensor SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Abso Technical Information TI 312e00 Solids Content Sensor 51508363 7510 SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Absorption Method The 7510 sensor is used for optical solid

More information

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS SERIES Winding Wire Granular Flaw Detector Orders accepted till September, 2003 Production to be discontinued from April, 2004 Fast and reliable minute granular flaw detection in winding wires Slim Reliable

More information

Watt Meter - Model 2335

Watt Meter - Model 2335 MORE WATT METERS Watt Meter - Model 2335 Dc to more than 1MHz Inputs up to 10A and 1000V 0.2% Uncertainty Low Power Factor Accuracy Peak or RMS Readings Isolated Inputs Harmonic Analysis Multifunction

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER USER MANUAL FOR VISIBLE SPECTROPHOTOMETER 1 Table of Contents 1. MAIN USAGES...3 2. WORKING ENVIRONMENT...3 3. MAIN TECHNICAL DATA AND SPECIFICATIONS...4 4. WORKING PRINCIPLE...5 5. OPTICAL PRINCIPLE...6

More information

CO2 OR HYDROCARBONS INFRARED SENSOR WITH INTEGRATED TRANSMITTER

CO2 OR HYDROCARBONS INFRARED SENSOR WITH INTEGRATED TRANSMITTER 1. FEATURES Analogue (voltage or dynamic pellistor) standard output Incorporated signal linearisation and temperature compensation suited for manufacturers without any specialist knowledge in IR technology

More information

Technical Information for the CDM7160 CO2 Module

Technical Information for the CDM7160 CO2 Module Technical Information for the CDM716 CO2 Module an ISO91 company The CDM716 CO2 module uses a nondispersive infrared (NDIR) sensor principle and compact optics to achieve excellent performance characteristics,

More information

GasSense NDIR INFRARED TRANSMITTER

GasSense NDIR INFRARED TRANSMITTER GasSense is an innovative high specification dual channel infrared gas sensor with integrated transmitter for the measurement of CO2, CO, CH4, N2O or hydrocarbons. Featuring automatic temperature compensation,

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

DISCRETE INPUT MODULE, 16 points

DISCRETE INPUT MODULE, 16 points INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Series 10-ZSE80/10-ISE80

Series 10-ZSE80/10-ISE80 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean

More information

VELTRON II Microprocessor Based Pressure & Flow Smart

VELTRON II Microprocessor Based Pressure & Flow Smart VELTRON II Microprocessor Based Pressure & Flow Smart Transmitter Accurate airflow measurement for demanding applications Precision Airflow Measurement An ONICON Brand VELTRON II with Automatic Zeroing

More information

RADIATED IMMUNITY TEST SYSTEM 6 GHz

RADIATED IMMUNITY TEST SYSTEM 6 GHz Integrated signal generator 80 MHz to 6 GHz Integrated RF switch network Integrated freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles Multiple options.5 TFT color display Safety

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Driesen + Kern GmbH. Product Specification. SenseAir S8. Commercial. Miniature infrared CO 2 sensor module. Document Rev Page 1 (10)

Driesen + Kern GmbH. Product Specification. SenseAir S8. Commercial. Miniature infrared CO 2 sensor module. Document Rev Page 1 (10) Driesen + Kern GmbH Product Specification SenseAir S8 Commercial Miniature infrared CO 2 sensor module 1 (10) SenseAir S8 Commercial Miniature infrared CO 2 sensor module Warning! ESD sensitive device!

More information

Diode Laser Systems In Gas Measurement

Diode Laser Systems In Gas Measurement Dr Roger Riley, Geotech Diode Laser Systems In Gas Measurement The application of laser diodes for improved biogas analysis Figure 2 Tuneable diode laser measurement technique Introduction The online analysis

More information

PyroMiniUSB Series Operators Guide

PyroMiniUSB Series Operators Guide PyroMiniUSB Series Operators Guide The PyroMiniUSB is a simple, compact infrared temperature sensor with USB communications. It measures the surface temperature of a variety of materials without contact.

More information

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OM-65H The OM-65H is a -wire type (4VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust,

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

CROSS STACK LASER GAS ANALYZER

CROSS STACK LASER GAS ANALYZER DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of density of HCl contained in l ue gas in waste incineration

More information

7110 MTF-FG 7110 MTF Measuring system Examples for complete measuring systems 7110 MTF or 7301 GWT with 7510 SAM-E Measuring system 7110 MTF or 7301 G

7110 MTF-FG 7110 MTF Measuring system Examples for complete measuring systems 7110 MTF or 7301 GWT with 7510 SAM-E Measuring system 7110 MTF or 7301 G Technical Information TI 313e00 Solids Content Sensor 51508361 7510 SAM-T/E Solids Content Sensor for Average Concentrations using the Light Absorption Method The 7510 SAM sensor is used for optical solids

More information

Radiated Immunity Test System 6 GHz

Radiated Immunity Test System 6 GHz The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator,

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Using the AcuDew Moisture Transmitter

Using the AcuDew Moisture Transmitter APPLICATION NOTE 2018_5-1 AcuDew Using the AcuDew Moisture Transmitter The AcuDew Transmitter is a two wire, 4-20 ma loop powered transmitter for continuous moisture measurement in process gases, glove

More information

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs

More information

Technical data sheet TDS0074

Technical data sheet TDS0074 Technical data sheet TDS0074 HYDROCARBON INFRARED SENSOR FOR EXTENDED TEMPERATURE USE, NON-CERTIFIED VERSION TYPE MSH-HC/NC/M PATENT NUMBER: GB 2372099B; US 6,753,967 B2 FEATURES Measures methane at both

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C nalog nd Non-Indicating Type, PID Control, Set Temperature y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID

More information

Bulk Flow Meter LB 442 CONTACTLESS MEASUREMENT

Bulk Flow Meter LB 442 CONTACTLESS MEASUREMENT Bulk Flow Meter LB 442 CONTACTLESS MEASUREMENT Mass flow determination using the LB 442 Versatile uses Contactless mass flow determination of solid matter on continuous conveyor systems Conveyor belts

More information

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible PHA & PHC STRIP CHART RECORDERS WITH BRILLIANT SIX-COLOR PRINTING Why use dot-matrix or fiber-tip pen printing when Fuji Electric s patented, cutting-edge recording technology offers an affordable inkjet

More information

SERVOPRO MultiExact PROCESS ANALYSERS APPLICATIONS FEATURES

SERVOPRO MultiExact PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS SERVOPRO The SERVOPRO is the next generation analyser family specifically designed to meet the needs of industrial gas producers and users, offering unparalleled operational performance

More information

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Ultraminiature Photoelectric Switches with Self-contained Amplifier Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x

More information

Data sheet and manual. SenseAir S8. Alarm 5% Miniature infrared CO 2 sensor module

Data sheet and manual. SenseAir S8. Alarm 5% Miniature infrared CO 2 sensor module Data sheet and manual SenseAir S8 Alarm 5% Miniature infrared CO 2 sensor module Key technical specification Item SenseAir S8 Alarm 5% Article no. 004-0-001 Target gas CO 2 Operating Principle Non-dispersive

More information

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE RGB Digital Fiberoptic Sensors CZ-K Series Features RGB three-light source Wide detection range of 70 ±20 mm 2.75" ±0.78" High-speed response of 300 µs Water-resistant sensor head IP-67 rated Detecting

More information

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters For over six decades, Forbes Marshall has been building steam engineering and control instrumentation solutions

More information

Product data sheet Palas Fidas 200 E

Product data sheet Palas Fidas 200 E Product data sheet Palas Fidas 200 E Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Long-term studies Emission source classification Distribution

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

CALYS 100. Field precision documenting multifunction calibrator

CALYS 100. Field precision documenting multifunction calibrator Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench

More information

[ tima-datasheet-en v11.1 ]

[ tima-datasheet-en v11.1 ] specifically designed for protection, automation and control applications in power systems 60 ns (99%) maximum time deviation single or dual 10/100Base-T Ethernet port(s) VLAN / IEEE 802.1Q support RS232

More information

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front

More information

CLIMATE. Climate sensors to ensure comfort and productivity

CLIMATE. Climate sensors to ensure comfort and productivity CLIMATE Climate sensors to ensure comfort and productivity CLIMATE We produce climate sensors to ensure productivity and comfort in animal production. dol-sensors manufactures sensors for temperature,

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Extractive continuous process gas analysis Series 6 CALOMAT 62

Extractive continuous process gas analysis Series 6 CALOMAT 62 Siemens AG 208 Overview The gas analyzer is primarily used for quantitative determination of one gas component (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially

More information