Model LS 250 Loop Scanner Operator s Manual. Version
|
|
- Ernest Sullivan
- 6 years ago
- Views:
Transcription
1 Model LS 250 Loop Scanner Operator s Manual Version
2 Contents 1. Introduction Description Model Nomenclature Operating Principle Specifications Location and Mounting Sensor Location Sensor Mounting Utility Connections Electrical Connections Plumbing Connection Operation Controls Threshold Level Adjustment Test Function Troubleshooting Maintenance Regular Maintenance Returns of the LS LS Enclosure Dimensions Accessories- Hot Metal Simulation Test Bar...18 Page 1
3 1. Introduction The Logika Technologies non-contact Loop Scanner, Model LS is designed to determine loop position for hot steel, aluminum and other metal mill production lines at temperatures as low as 250 o C (480 o F). It is particularly well adapted to horizontal or vertical loop control for wire rod and bar. The LS includes a rugged IP66 enclosure protecting state-of-the-art electronics and will withstand the harsh conditions present in heavy industrial environments found in steel mills and other primary metallurgy plants. The advanced sensor detector and optics allows the sensor to be installed remotely from the hot metal target, further protecting the electronics and extending the life of the sensor without affecting resolution. Figure 1: Typical Application Hot Bar Rolling Page 2
4 2. Description 2.1 Model Nomenclature Record your Hot Metal Detector s complete Model Number here: LS Model Scan angle Power Input Sensitivity Output Config LS 10: : 110 VAC H:High 10H=0-10V* 30: : 220 VAC 250 C 10L=10-0V 50: 50 24: 24 VDC N:Normal 400 C 20H=4-20mA 20L=20-4mA *0V = no target Serial Number Fig: 2.1: Model Number 2.2 Operating Principle Detector- The LS uses a Lead Sulfide (PbS) photocell, which has a very strong signal output characteristic compared with other detector materials for the range of infrared energy emitted from steel. The high signal-to-noise ratio that results from this superior detector gives reliable measurements, even through steam, water and dust and at steel target temperatures as low as 250 o C (480 o F). Figure 2.2 shows the spectral response of various types of photocells with the infrared spectral output of hot steel. Page 3
5 Figure 2.2: Graph of Spectral Response of Various Types of Photocells and Steel Scanning System- The LS uses a scanning optical bench that detects the target hot metal angular position in the sensor s field of view to enable precise position control in metal processing lines. The optical field is scanned using a multi-faceted mirrored rotating drum that reflect the energy from the hot metal target in the scanning field to the PbS detector. The electronics calculate the angular position of the hot target and convert this to an analog signal at the sensor output. This arrangement is shown in Fig 2.3. Figure 2.3: LS Scanning System Diagram Vertical Scanning Angle- The LS is manufactured with one of three vertical field scanning angles (10, 30 or 50 ), selectable at the time of sensor purchase. This enables the sensor to cover the entire process area but not scan beyond the process line where interfering Page 4
6 sources of infrared energy may be present. Fig 2.4 shows vertical scanning field size versus hot metal target distance from the sensor. Vertical Scanning Field Scanning Angle 1 m Away 2 m Away 3 m Away 4 m Away 5 m Away 10 Deg 17 cm 35 cm 52 cm 70 cm 87 cm 30 Deg 55 cm 110 cm 160 cm 215 cm 270 cm 50 Deg 93 cm 190 cm 280 cm 370 cm 470 cm Figure 2.4: Size of Vertical Scanning Field vs. Distance From Hot Metal Target Vertical Scanning Field example: A hot metal target located 4 meters (13 ) from the front of the LS sensor with a vertical scanning angle set at 30 o, the vertical scanning field is 2.15 meters. Horizontal Scanning Angle- A manually adjusted shutter at the front of the sensor is used to determine the horizontal viewing angle from 1 to 3 (see Section 3.1 Mounting Distance ). For example, for a shutter width angle of 1 and a distance to the hot metal target of 4 meters (13 feet), the horizontal field width is 8 mm. A positive output signal will result if any portion of the hot metal is within the 8 mm scanning field. This Shutter is used to narrow the horizontal view while preventing false outputs by effectively blocking out adjacent emission sources. 2.3 Specifications Spectral response 1 to 3 µm, peak wavelength of 2.2 µm Detector PbS detector with superior signal-to-noise ratio for low temperature and low emissivity targets even in the presence of background infrared interference and roller heat radiation. Response Relay 10ms, 2-4ms for analog output (dependant on scan angle) Target Temperature 250 o C (480 o F) minimum on high sensitivity setting, 400 o C (750 o F) minimum Range on normal sensitivity setting. Power Input 24 VDC, 110VAC or 30VA Housing Hermetically sealed cast aluminum enclosure rated IP66, includes hinged protective hood for ease of service with air purge connection and separate module for cooling water connections Weight 9 Kg (20 lbs). Page 5
7 3. Location and Mounting 3.1 Sensor Location The mounting distance between the LS sensor and hot metal target should enable the sensor s field of view to cover the entire measuring area where the target may appear. The sensor scanning direction is from top to bottom of the vertical sensor field and its output corresponds to the first hot edge detected at the top of the scanning field. Mounting Distance- 1. Select an approximate sensor mounting distance from the hot metal target based on the following table. Consult Figure 3.1 on the size of the detection scanning field to help determine a good mounting distance for the configured scanning angle of your sensor (10 o, 30 o, or 50 o ) and to be sure that the distance that the sensor is mounted from the target will cover the entire process area. 2. For very hot processes the sensor mounting location should be far enough from the process line to protect the sensor from excessive heat. The maximum ambient temperature around the sensor without water cooling protection is 50 o C (120 o F). 3. For cooler target metal the sensor mounting location should be close enough to give the detector sufficient infrared energy to reliably detect the target. 4. The LS Sensor s scanning plane should be vertical to the hot metal target. Please see the following chart for LS Sensor mounting distance guidelines: LS Sensor Mounting Target Distance Product min (m) max (m) min (inch) max (inch) Wire Rod Bar Billet Blooms >2 >78.74 Strip Steel Thin Plate Thick Plate Slab >2 >78.74 Page 6
8 Figure 3.1 LS sensor to target installation distance Interference- Background infrared radiation sources, such as other hot processes behind the target and reflected sunlight, should be minimized or eliminated: 1. Select the appropriate scanning angle when the sensor is ordered so that the sensor does not over-scan the target. This will minimize or eliminate sources of infrared interference behind the target hot metal. 2. The sensitivity potentiometer on the LS Sensor s Control Panel can help eliminate sources of infrared interference. See the Operation chapter of this manual for additional details on sensitivity threshold adjustment. 3. Adjust the shutter at the front of the LS Sensor s protective front cover to limit the field width. This will minimize or eliminate horizontal sources of infrared interference. 4. If necessary, install a background radiation screen between the target and the interference source to block its infrared energy from reaching the detector. 5. Choose a sensor location that minimizes excessive smoke and concentrated steam in the path between the sensor and target. If this is not possible then it is recommended that additional ventilation such as air curtains or fans be used to clear the area so the sensor can see the hot metal target. 3.2 Sensor Mounting Mounting Bracket- The LS has an adjustable mounting foot designed to allow for easy rotation through horizontal and vertical axes. The LS sensor is affixed to a support with a single 18 mm bolt through the LS Sensor s base mounting stand. The support must be sufficiently rigid to absorb excessive site vibrations that could affect the precision or output of the detector. Air, Cooling Water Fittings- The LS has a water-cooling jacket and an air-purged hood for protection of the window glass. These sensors can be used in harsh environments with high temperatures, steam, dust and smoke. Please see Section 4.2 Plumbing Connection and Section 4.3 Air-Purge Connection for further details on installing these provisions for your sensor. 4. Utility Connections 4.1 Electrical Connections Electrical Overview- All electrical connections (power and signal) to the LS are made via a 15- pin connector with ground. The sensor is supplied with a mating connector at the back of its enclosure and a standard 2-meter cable with the quick-connect assembly mating to the Page 7
9 sensor and feruled wires for the junction box connections. Other cable lengths are available from Logika Technologies upon request. Cable Specification- Multi-lead cable of 16 x 20 gauge (9 x 0.6 mm²) plus shielded 7 x 24 gauge (7 x O.34 mm²) Teflon insulation for high temperature applications. Outer metallic braid for mechanical protection. Overall diameter of 9 mm. Minimum bending radius of 30 mm. Each lead is color-coded. Power Connections- Power Input (please specify power input at time of order). White/Red, White/Brown 110VAC/60Hz White/Black, White/Brown 220VAC/50Hz White/Red, White/Black DC24V Junction Box Wiring- Please see Figure 4.1 for the sensor wiring diagram. The supplied cable should be connected directly to the terminals of a junction box. All cables must be shielded all the way to the console with the shield connected to ground to eliminate electrical noise. Any unused output wires must have insulation protection or be connected to a free terminal of junction box. Power Connections- Power Input (please specify power input at time of order). White/Red, White/Brown 110VAC/60Hz White/Black, White/Brown 220VAC/50Hz White/Red, White/Black DC24V Voltage Output VDC/10 ma, <100 mv ripple, proportional to angular position of hot metal in target field. Transistor Static Output: Push-pull output maximum current 100 ma, output voltage 0 VDC or 24 VDC Output Response time: o 10 degree scanning field: 2ms o 30 degree scanning field: 2ms o 50 degree scanning field: 4ms Relay Output- Single-pole double throw contact, contact capacity rating is 250VAC/10A, relay operating time = 7.5 ms, relay release time = 3 ms. Note: Static output and Relay output are isolated, which means two types of outputs may be used, separately or both at the same time. Page 8
10 Sensor Diagnostics Outputs- Relay and voltage signals to indicate sensor conditions. 1. Control Output: Normally 24V, a 0VDC diagnostic alarm indicates dust or vapor interference on glass, target temperature drop, or signal saturating. 2. Alarm Output: Normally 24V, a 0VDC diagnostic alarm indicates no power input, scan motor abnormal, or interior housing temperature is higher than 55 o C (130 o F). 3. Signal Amplitude Output: Signal amplitude is an analog voltage signal, VDC, proportional to the photocell output. This signal may indicate that the sensor s protective glass lens requires cleaning or that the detector sensitivity needs to be increased. Signal amplitude strength is influenced by: Installation position and location of sensor in process Size of the target Temperature of the target Distance between the sensor and the target Vapor in the field Dust on the lens Sensitivity Adjustment Setting 4. Test Point: Used to compare reference pulse with signal pulse during manufacture. 5. Sensitivity Adjustment: A 5k potentiometer may be connected between this point and Common to enable remote adjustment of sensitivity. Note that if this feature is used, the local sensitivity pot at the back of the instrument must be turned to Minimum. Page 9
11 Figure 4.1: Sensor Wiring Diagram 4.2 Plumbing Connection Description- Water cooling is required when the ambient temperature at the sensor s location is higher than 50 o C (120 o F). Temperatures above this level require protection for the Page 10
12 electronics. A standard cooling water fitting is available at the sensor enclosure and copper heat exchanger tubing is embedded in the sensor housing to facilitate efficient heat removal from the sensor using circulating cooling water. Cooling water allows the sensor to be placed in ambient temperatures up to 120 o C (250 o F). Cooling Water Requirements Clean industrial water Maximum water inlet temperature of 25 o C (77 o F). Maximum water pressure of 4 bars (60 psi) Water flow rate of 1 to 2 L/min (0.26 to 0.53 gal/min) Connection- Use 3/8 flexible hose to connect the plant s cool water supply to the sensor cooling water fitting and secure with a hose clamp. Refer to Figure 4.2, Ambient Temperature vs. Water Flow Rate Graph, to determine the cooling water flow rate for the ambient around the sensor. Figure 4.2: Ambient Temperature vs. Water Flow Rate 4.3 Air Purge Connection Description- Compressed plant air can be used to prevent dust and vapor from entering the protective shroud around the lens of the sensor. Using plant air with the sensor will reduce lens cleaning maintenance and prolong sensor life where dust or corrosive vapors are present. Compressed Air Requirements Page 11
13 Must be clean, dry air free of contaminants and oil. Poor purge air quality will lead to dirty glass which may decrease sensor performance and increase sensor maintenance. Air filtration prior to the sensor purge inlet fitting is recommended for purge air of questionable quality. Air Pressure range of 50 to 200 g/cm 2 Air Flow rate of 4 to 16 L/min (0.14 to 0.56 ft/min) Connection- Connect the plant purge air to the air purge fitting on the sensor s lens shroud using a ¼ air line. The purge air escapes out of the sensor shroud and dissipates into the environment. Page 12
14 5. Operation 5.1 Controls The LS Sensor s Control Panel is located under the protective cover plate on the back of the sensor. The following functions are available at the Control Panel. Please see Figure 5.1 for location of the controls defined below. LED Status Indicator Light- Off: Sensor in standby mode no target detected Green: Normal target detection. Red: Detector signal saturated (too much input energy). Sensor Test Button- produces a positive detection output Threshold Level Adjustment switch- adjust sensitivity of the detector. Clockwise increases sensitivity. Figure 5.1: Control Panel Page 13
15 5.2 Threshold Level Adjustment 1. The LS includes a Threshold Level Adjustment. The user adjusts the Threshold Level Switch on the sensor control panel at installation to determine the base detector signal according to the application requirements. If greater sensitivity is required for the application then adjust the width of the shutters at the front of the sensor outward to allow more infrared energy to reach the detector 5.3 Test Function To test the electrical integrity of the LS sensor, follow the steps below: 1. Connect power to the sensor. 2. Press and hold the TEST button on the control panel when hot metal is not in the target field of the sensor. The LED on the Control Panel should turn on (green). The test button simulates a positive signal from the detector. It will also actuate the sensor s relay output (close the alarm circuit) to test the control function in your system as long as the test button is pressed. 3. Release the test button to return to normal operation and end the test function. 5.4 Troubleshooting No Target Detection- If the LED does not turn green when a hot metal target is in the LS Sensor s field of view, there are two possibilities: 1. The Horizontal Scanning Angle Shutter located at the front of the sensor is not allowing sufficient radiation to reach the PbS sensor. Manually adjust the shutter to allow the target s infrared energy to reach the detector. 2. The threshold switch is set incorrectly, select the alternate setting. False Target Detection- if a target is detected when no process material is in the scanning field check for background sources of radiation and eliminate them where possible and/or adjust the shutter opening by incrementally closing the shutters until the problem has been resolved. Page 14
16 Diagnostic Signal Output Detected- Check the diagnostic signals available and their status indication (see Section 4.1 Sensor Diagnostic Outputs for details). Correct fault conditions as necessary. See additional notes below: No Power- Check that the sensor wiring connections are correct, that the connections are secure and tight and that the power supply is proper and normal. Terminals 4C/3B normally will output a signal of 24VDC. If the output goes to 0V between those terminals then check for the following conditions: 1. If the housing temperature is over 55 o C (130 o F), then water cooling must be used (see section 4.2). If water cooling is already in use, then check the water s inlet temperature and for flow restrictions to the unit. 2. Scanning Error (motor error or circuit error) means that the rotating drum motor may have failed. Please contact Logika Technologies for resolution. Terminals 2A/3B normally will output a signal of 24VDC. If the output goes to 0V between those terminals then check the Sensor front window for dirt. Should this not fix the issue switch the sensitivity adjustment to the other setting. 6. Maintenance 6.1 Regular Maintenance Normally, the LS does not require maintenance at a fixed period. However regular attention to the following will ensure steady operation of the sensor: Lens Cleaning- Routinely check the LS sensor s glass for dust or oil residue. Open the lens shield board at the front of the sensor by unscrewing the fastening hardware on the shield and clean the glass with alcohol and lens paper or soft cloth. Adjustments- The threshold level sensitivity (see Section 5.2) and the light shutter at the front of the sensor may require occasional adjustment. The screw at the front of the sensor allows adjustment of the light shutter. Page 15
17 6.2 Returns of the LS Contact Logika at LOGIKA with the Serial Number of your sensor before you return our product. If we are unable to solve the problem by phone or , we will then provide you with a return authorization number. Do not return the LS without an authorization number. If the product is out of warranty, we will provide a repair estimate and then complete the repairs after your approval. Page 16
18 7. LS Enclosure Dimensions Page 17
19 8. Accessories- Hot Metal Simulation Test Bar In order to facilitate the installation, use and maintenance of LT-HSM hot metal detector and other infrared sensors, we have developed our hot metal simulation test bar, Model TP-1. This process simulation tool uses an AC power supply of 110/220V with the maximum power of 500 W. The power output can be adjusted by the potentiometer on the test bar to simulate different process temperatures. When using the TP-1 test bar, please note the following: The power supply should be supplied with a ground. The test bar is constructed of sensitive electronic components. Use care when handling the unit. This test bar should be used for a maximum of one (1) hour on a constant basis. When not being used, please switch off the test lamp or darken it. When it is used again, turn on or lighten the test lamp. When the lamp tube is damaged, return it to Logika Technologies for repair or replace the infrared lamp source at your site. The lamp tube used is an iodine tungsten lamp tube of 110/220 V, 500 W. Figure 8.1 Hot Metal Simulation Test Bar Page 18
IS-3000 SERIES INFRARED SCANNER
IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE
More informationModel WHD Weld Hole Detector Operator s Manual. Rev 1.1
Model WHD Weld Hole Detector Operator s Manual Rev 1.1 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle... 2 2.3 Specifications... 3 3. Location and
More informationRota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications
Scanning HOT METAL DETECTOR Rota-Sonde DC4500 Smart display with Signal level Easy alignment with Laser Line Design for the most difficult applications Very High Sensitivity 360 F Lt 1445 1 Applications
More informationModel OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version
Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual Version 11-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle...
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION OF SENSOR MEASUREMENTS OF LENGTH OF ROLLED MATERIALS IPSS: 2-07-037-13 (First Revision) Corresponding Indian Standard does not exist Formerly-: IPSS:
More informationSR Series Self-Contained Two-Color Infrared Thermometers
SR Series Self-Contained Two-Color Infrared Thermometers The SR series self-contained, two color infrared thermometers Introduction The SR Series infrared thermometer from Ircon is a two-color thermometer
More informationSILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets
SILVER SERIES Low Cost, Single-Wavelength (1λ) Industrial Infrared Thermometers SSDS2013 Reliable compact industrial infrared thermometers for Temperatures below 3632 F/2000 C Non-reflective target materials
More informationLabel Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor
Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN
More informationUltraminiature Photoelectric Switches with Self-contained Amplifier
Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x
More informationE3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features
bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that
More informationProduct Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control
s 1022/1025/1029C/1032/3629B 3629B Product Data Sheet s 1022/1025/1032 Single phase power controllers Current ratings from 10 to 70 Amps 1022-0 to 5VDC or pot input 1025-4 to 20 ma signal 1032 Current
More informationeye in hell CD 3002 Sensor Manual
Your eye in hell CD 3002 Sensor Manual Siemens Laser Analytics AB Oct 2001 CD 3002 Sensor manual Document number: CID 3002-1102 Rev. 2A LDS 3000 Sensor manual Content Content 1. CD 3002 1 1.1 General 1
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationES Series Features Detecting distance twice that of conventional
Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output
More informationLA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS
SERIES Winding Wire Granular Flaw Detector Orders accepted till September, 2003 Production to be discontinued from April, 2004 Fast and reliable minute granular flaw detection in winding wires Slim Reliable
More informationInfrared Temperature Measurement System
Infrared Temperature Measurement System Modline 3 - the most advanced micro computer based non-contact temperature measurement system, featuring high performance, reliability and versatility. The Modline
More informationConnections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON
Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures
More informationEmitting and receiving element pitch: 10 mm in
Small / Slim Object Detection Area Sensor Cross-beam scanning system to detect slim objects Letter or visiting card detectable! Slim objects can be detected by using the cross-beam scanning system. Emitting
More informationBuilt-in Amplifier Photoelectric Sensor
Built-in Amplifier Photoelectric Sensor Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance Conforms to EN and IEC standards Incorporating polarizing function,
More informationZ4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.
/ Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationEE-SPY311/411/312/412
Accurately Detects Objects Placed in Front of Mirror-like Background H A mirror-like background can be used when the distance between the sensor and the background is 20 mm or more H Detects an object
More informationDistance-setting Photoelectric Sensor
Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection
More informationEE-SPY311/411/312/412
Accurately Detects Objects Placed in Front of Mirror-like Background A mirror-like background can be used when the distance between the sensor and the background is 20 mm or more Detects an object as small
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationLong-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional
Long-distance Separate-amplifier ES Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output
More informationFrequency Range: MHz. Efficiency: 80% Temperature Range: -20 to 65 C Max VSWR: 3:1. Class: Supply Voltage: 32.0V
Part Number Revision 0.B Release Date October 19, 2007 Revision Notes Final production release Amplifier Name Technical Specifications Summary Frequency Range: 86-108 MHz P1dB: 500 Watts CW Class: C Supply
More informationFST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL
FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL 20020628 CONTENTS DESCRIPTION... 3 OPERATION... 4 Power Supply...4 Output Range...4 Temperature Operating Range and Temperature Limits...4
More informationHydraulic Clamp Carrier. Installation & Operation Manual
Hydraulic Clamp Carrier Installation & Operation Manual Hydraulic Clamp Carrier Installation & Operation Manual Quick Machinery Company 8272 Peninsula Drive Kelseyville, CA 95451 phone: (707) 272-6719
More information500C Advanced Training Outline
500C Advanced Training Outline 1. Opacity Basics 2. Math used with the 500C 3. Trasmissometer Evolution Single Pass 1. Simple 2. Ambient light interference 3. Difficult to verify calibration Double Pass
More information10 to 30 VDC (10% max. permissable ripple peak-to-peak)
R Background Suppression Sensor Photoelectric Sensor With Adjustable Setting Distance in Rugged Metal Housing H Stable detection regardless of material color or size of sensing object: 2% or less black/white
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects
929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~
More informationBuilt-in Amplifier Photoelectric Sensor
Built-in Amplifier Photoelectric Sensor Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance Conforms to EN and IEC standards Incorporating polarizing function,
More informationHPA Series. Self-contained Photoelectric Controls with High Functions. Specifications CLICK FEATURES ORDER GUIDE. Pre-leaded type (2m lead)
6 HPA Series Specifications Self-contained Photoelectric Controls with Functions FEATURES Strobe Light Emission, Margin Regulation, Front Incoming Light Display, and Output Inhibit Functions Allow Sensing
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationUltrasonic Displacement Sensor E4DA
Sensing Supply voltage Output Ultrasonic beam Ultrasonic Displacement Sensor Sensor s Narrow Ultrasonic Beam Accurately Detects Small Objects, Provides Linear Analog Output For Inspection, Measurement
More informationGSIR 6816 Series Infrared Thermometer
GSIR 6816 Series Infrared Thermometer Objects having temperatures above absolute zero radiate infrared energy all the time. This infrared energy has a certain functional relations with the surface temperature
More informationFEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.
273 Cylindrical Photoelectric Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO PHOTO MEASURE -LS200
More information40 mm Beam Pitch General Purpose Area Sensor. Failure monitoring
OTHER SUNX PRODUCTS NA0 SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Interference prevention Slim and intelligent Refer to p.9l for the light curtain. Slim body Failure monitoring
More informationLight Pipe. Series LPS100, LPS150, and LPS250. Product Bulletin LPS Release A, Effective January Table of Contents
3 Light Pipe Series LPS100, LPS150, and LPS250 Product Bulletin LPS Release A, Effective January 2008 Table of Contents User Information................................................... 2 Product Description.................................................
More informationINSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS
CU-101 JUNE 2, 2009 INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS APPLICATION The FIREYE fiber optic scanners have been designed for installation on burners where movable vanes, air
More informationE3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor
Authorised Distributors:- AS & AAIN INDIA PVT TD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) Tel : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Fiber Glossy Object
More informationPhotoelectric Switches for Harsh Environments
Photoelectric Switches for Harsh Environments HP8 Series For even harsher environments Die-cast housing for strength and shock resistance High-performance seal Resistance to the most advanced cutting oils
More informationUser Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20
User Manual Laser distance sensor series OWLE 1/20 English 1 General notes... 3 2 Functional principle... 4 3 Mounting instructions... 4 4 Application hints... 9 5 Teaching the OWLE...11 6 Technical data...17
More informationLong Range Metal Body Sensor
R Long Range Metal Body Sensor 30 m Range With Advanced Fuzzy Logic H Mutual interference protection H NPN/PNP switch selectable output H M12 plug-in connector H Meets IP67 and NEMA 4X, 6P H Vibration
More informationThis section is specifically about safety matters
6 4 ) 5 1 5 6 4 1 -, 1 8-4 6-4 1 5 6 4 7 + 6 1 ) 7 ) 5 2 - -,, - 6 - + 6 4. 4. 2 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information
More informationNon-Radiometric Measurement. Innovative concept of on-line measurement
Innovative concept of on-line measurement MCT NIR On-line moisture and coating measurement Near Infrared (NIR) Technology: All molecular bonds absorb specific wavelengths of light. Hydrogen bonds including
More informationHLC-1000 High-limit Humidity Control
FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification
More informationOperating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)
Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
44 PHOTO PHOTO Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F- Glossary of terms... P.549~ guide... P.49~ General precautions...p.55~ Recognition Make sure to use
More informationBand-Master ATS Nano Pneumatic Banding Tool Operating Instructions
Band-Master ATS 601-118 Nano Pneumatic Banding Tool CONTENTS 601-118 Overview... 3 Safety.... 5 Initial Tool Set-up... 5 Regulator assembly mounting... 5 Attach tool head to regulator.... 6 Operating instructions...
More informationINSTRUCTION MANUAL INF Fax: (503)
INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up
More informationIP Series DUAL POWER AMPLIFIERS
OPERATING INSTRUCTIONS IP Series DUAL POWER AMPLIFIERS IP-600D IP-450D IP-300D TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 4 3. FEATURES... 4 4. HANDLING PRECAUTIONS... 4 5.
More informationFrequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 60 C Max VSWR: 5:1. Class: Supply Voltage: 28.0V
Part Number Revision 1.c Release Date July 24, 2007 Revision Notes Amplifier Name Technical Specifications Summary Frequency Range: 50-88 MHz P1dB: 60 Watts CW Class: A Supply Voltage: 28.0V Gain: 36dB
More informationSPECIFICATION NO Model Automatic GTAW Welding System
1.0 Introduction The Model 227-3 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small
More informationEducational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539
GAIN 1 10 Instruction Manual with Experiment Guide and Teachers Notes 012-06575C *012-06575* Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539 100 CI-6604A LIGHT SENSOR POLARIZER
More informationNA DigiParts GmbH. Small / Slim Object Detection Area Sensor
953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business
More informationDigital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)
Digital Panel Meter Subminiature Digital Panel Meter that Accepts DC Input Ultra-compact DIN-size (48 x 24 (W x H)) body. Mounting thickness of only 2 mm required. Highly visible display with 10.2-mm-high
More informationELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)
ELPMB27 Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs) Safety Instructions Before using the wall mount, make sure you read all of the safety instructions
More informationATD AMP Variable Speed Reciprocating Saw Owner s Manual
ATD-10535 7 AMP Variable Speed Reciprocating Saw Owner s Manual Manufactured in China To ATD Tools, Inc. Specifications TECHNICAL SPECIFICATIONS Voltage: 120V Frequency: 60Hz Power input: 7 Amps No load
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationBeaming Optical Length Tester (BOLT)
O.W.L. MANUFACTURER OF QUALITY OPTICAL FIBER TEST EQUIPMENT OPTICAL WAVELENGTH LABORATORIES Beaming Optical Length Tester (BOLT) Operations Manual Version 1.0 November 8, 001 OWL Part BOLT-1 TABLE OF CONTENTS
More informationA cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications
A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications The Micro 100 Drives have been designed with a Pulse Width Modulated (PWM) regulator to produce clean DC current to
More informationSelf-contained Photoelectric Sensors PZ2 Series
Self-contained PZ Series Features World s smallest photoelectric sensors Excellent mirror surface detection IP-7 rated waterproof can operate side by side Detecting Distance Thrubeam 7, Retro-reflective
More informationSable Frame CineGrey 3D
Sable Frame CineGrey 3D Ambient Light Rejecting Fixed Frame USER S GUIDE (spring type) Congratulations on your new Sable Frame purchase! The screen material included is our ISF Certified CineGrey 3D which
More informationElectronically controlled proportional pressure regulating valves
Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..
More informationE3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance
Built-in Amplifier Photoelectric Sensor Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance Satisfies the requirements of IP67, NEMA 6P, and IP67G (oil-tight).
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationSarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:
2 3 IMPORTANT SAFETY NOTE: Before operating this device, please read carefully this User Manual and be familiar with its contents prior to using this equipment. To help avoid potential serious injury to
More informationCapacitive Proximity Sensor
Capacitive Proximity Sensor Compact and Ideal for Robot Hands and Various Built-in Applications for LCD, Wafer, and PDP (Plasma Display Panel) Detection Flat head is only 5.5-mm thick. Robot Cable ensures
More informationLaser Displacement Sensor Z4M. Ordering Information
Laser Displacement Sensor Compact Displacement Sensor with 1.5-micron Resolution Offers Long-distance Measurement for In-line Production Inspection High resolution with 3 user-selectable response speed
More information1208 P10-VHF-H-20. Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 70 C Max VSWR: 5:1. Class: Supply Voltage: 28.
Part Number Revision 2.C Release Date July 24, 2007 Revision Notes Included Mechanical Drawings Amplifier Name Technical Specifications Summary Frequency Range: 170-230 MHz P1dB: 10 Watts CW Class: A Supply
More informationQR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW
QR12 DESIGN FEATURES Low profile assembled height of 0.99" Bearing design simplifies encoder attachment Resolutions up to 20,000 lines per revolution SIN/COS outputs available up to 1250 LC 4, 6 or 8 pole
More informationfigure 1 figure 2 INSTRUCTIONS AND TIPS FOR THE INSTALLATION OF THE HC MODEL CINEMA MIRROR x = y
CONSIDERATIONS 1 Cinema Mirror is an active optic set to be installed in false ceilings hiding the projection equipment, and that through a pulsation it opens a floodgate of 335x335 mm., allowing the projection
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More information6.00 INFRARED ANALYZER
FREQUENTLY ASKED QUESTIONS PAGE 1 OF 7 QUESTION 1 What is the difference between the application for the IRPC one constituent, and the IRPC multi-constituent? ANSWER 1 The IRPC NIR Analyzer, one constituent,
More informationCATALOG LISTING SPECIFICATIONS 11 30mA 22 to 130mm (White Paper), 22 to 70mm (Black Paper) 3 to 130mm (White Paper) Ambient light Seal
Convergent Laser Measurement Sensor Model HLB-D130DN Very small or thin parts can be detected by differences in distance, unaffected by color or reflection rate of the target object. Size (12 x 16.3 x
More informationTECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging
TECHNICAL DATASHEET #TDAX102000 35A DC MOTOR CONTROLLER P/N: AX102000 Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging with Electronic Assistant Features: Unidirectional or bi-directional
More informationRECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized
RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized 1.0 Description The Manufacturer shall provide a Rectangular Rapid
More informationSPECIFICATIONS Type Catalog listing Power supply Consumption current Detecting distance Focal distance Focal spot diameter Operation mode
Long-Distance Detection Laser Sensors Model High-accuracy detection of very small targets using the direct reflection method. Detecting a long distant and very small spot. Switching output type: 0.1 mm
More informationECE 203 LAB 6: INVERTED PENDULUM
Version 1.1 1 of 15 BEFORE YOU BEGIN EXPECTED KNOWLEDGE Basic Circuit Analysis EQUIPMENT AFG Oscilloscope Programmable Power Supply MATERIALS Three 741 Opamps TIP41 NPN power transistor TIP42 PNP power
More informationHPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier
Ultraminiature Photoelectric Sensors with Self-contained Amplifier HPJSeries HPJ Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8mm (thru scan model) 30
More informationAC AC AC
AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
497 Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.59~ Sensor selection guide... P.475~ General precautions...p.5 PHOTO PHOTO Conforming
More informationJR12 Jam Nut Mount Optical Encoder
Improving the Quality of Life through the Power in Light JR12 Jam Nut Mount Optical Encoder QPhase Design Features: Replaces Size 15 Pancake Resolver Bearing design simplifies encoder attachment Resolutions
More informationTable of Contents. B. Base Tool Changer...2 MC-6 Manual Tool Changer...2
Table of Contents B. Base Tool Changer...2 MC-6 Manual Tool Changer...2 1. Product Overview... 2 1.1 Master Plate Assembly... 2 1.2 Tool Plate Assembly... 3 1.3 Optional Modules... 3 2. Installation...
More informationOrtel (Lucent) Fiber Optic Interface AC
Ortel (Lucent) Fiber Optic Interface 144-701-1AC Serial Number March 11, 2010 CD P/N 098-00126-000 Revision B ORTEL (LUCENT) FIBER OPTIC INTERFACE 1. GENERAL INFORMATION... 1 1.1. SCOPE OF OPTION... 1
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More informationInstallation Tech Note Dallas, Texas
AMC B40A40AC Installation Tech Note Dallas, Texas May, 2010 ! CAUTION! Do NOT apply air pressure to release the collet while the servo motor is rotating. The servo motor spindle must be FULLY STOPPED before
More informationBATAILG TAIL GAS ANALYZER. Rev. 1.1
BATAILG TAIL GAS ANALYZER Rev. 1.1 The Tail Gas Analyzer is part of the BAGGI BASE Instruments Series. They are the result of combining the latest state-of-the-art-technology with over 60 years of industry
More informationezframe CineGrey 5D Ambient Light Rejecting Fixed Frame Screen
1 ezframe CineGrey 5D Ambient Light Rejecting Fixed Frame USER S GUIDE Congratulations on your new ezframe purchase! The screen material included is our award winning CineGrey 5D which is a front projection
More informationOperating Manual. Model 721N. Visible Spectrophotometer
Operating Manual of Model 721N Visible Spectrophotometer 1 Table of Contents 1. Chief uses... 3 2. Working Conditions... 3 3. Main Specifications...3 4.Operating Principles...4 5. Optical design...4 6.
More informationXRC X-Ray Calibration System
XRC X-Ray Calibration System Technical Description Contents 1. Equipment overview 2. X-ray Beam Specifications 3. The Control Console 4. Radiation Safety 5. Filters 6. X-ray Generator & Heat Exchange Equipment
More informationEltec Models and Long Range Passive Infrared Thermal Telescopes
Eltec Models 862-61 and 862-71 Long Range Passive Infrared Thermal Telescopes Please Note: For new applications, Eltec recommends the 864 Series which are low power and hermetically sealed. HOWEVER, Eltec
More informationE3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)
Distance-settable Photoelectric Sensor Switching between background and foreground suppression (BGS/FGS) enables detecting a variety of objects under various background/foreground conditions. Influence
More informationSERIES 200TIG/250TIG
SERIES 200TIG/250TIG STICK TIG 1 CONTENT 1. Safety 3 2. SUMMARY 4 3. ELECTRICAL PRINCIPAL DRAWING 5 4. PARAMETERS 6 5. INSTALLATION 7 6. OPERATION 9 7. OPERATION NOTICES 11 8. POSSIBLE PROBLEMS IN WELDING
More information4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System
USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-026 2017A-0420 4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System SYSTEM INSTALLATION INFORMATION Description The DIN
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More information