SPD Cross Reference List
|
|
- Lauren Parrish
- 6 years ago
- Views:
Transcription
1 SPD Cross Reference List Advanced Power Technologies (APT) Current Technology Joslyn Siemens Square D *click on competitors name to view their products*
2 Voltage codes Competitor Make: APT (Advanced Power Technologies) APT Competitor Web: Codes Description EE Codes 1 Split-phase - 3 wire + g - 120/240V 240S Model Information 11 Single Phase - 2 wire + g - 120V - TE/XTE Series - NEMA 4 enclosure standard ka per Phase Eaton Electrical Model 12 Single Phase - 2 wire + g - 230V 230L HPS 80 SPD080.2N 2 Three phase Wye - 4 wire + g - 120/208V 208Y HP 120 SPD120.2N 3 Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H How to read APT part number: TE 6 HPS /04 /SC Series Voltage Model Enclosure Other code # Options 4 Three phase Wye - 4 wire + g - 277/480V 480Y 5 Three phase Delta - 3 wire + g - 480V 480D 6 Three phase Delta - 3 wire + g - 240V 240D 7 Three phase Wye - 4 wire + g - 220/380V 400Y 8 Three phase Wye - 4 wire + g - 347/600V 600Y 9 Three phase Delta - 3 wire + g - 600V 600D Suffix Description EE Suffix /CX Upgrade to 120kA SDP120 /CL Upgrade to 160kA SPD160 /DC Form C 2 /SC Surge Counter 3 /FM Flushmount (NEMA 1) L /04 Standard NEMA 1/3R/4/12 enclosure N /4X NEMA 4X P /4S NEMA 4X Stainless Steel P
3 APT Continued Voltage codes APT Codes Description EE Codes 1 Split-phase - 3 wire + g - 120/240V 240S Model Information 11 Single Phase - 2 wire + g - 120V - TE Series - External Mount (Modular) ka per Phase Eaton Electrical Model 12 Single Phase - 2 wire + g - 230V 230L XAL SPD Three phase Wye - 4 wire + g - 120/208V 208Y XAS SPD Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H XBL No Cross 4 Three phase Wye - 4 wire + g - 277/480V 480Y XBS SPD Three phase Delta - 3 wire + g - 480V 480D How to read APT part number: TE 6 XAL 15 E1 Series Voltage Model ka Rating Enclosure code # 6 Three phase Delta - 3 wire + g - 240V 240D 7 Three phase Wye - 4 wire + g - 220/380V 400Y 8 Three phase Wye - 4 wire + g - 347/600V 600Y 9 Three phase Delta - 3 wire + g - 600V 600D Suffix Description EE Suffix X Surge Counter 3 E Remote Display - F Extended range EMI/RFI filter 2 D Rotary Disconnect M,O,Q T Thru-Door Rotary Disconnect - 2 Type 2 SPD with cul 2,3 K Rotary Disconnect M,O,Q S Thru-Door Rotary Disconnect - Suffix Description EE Suffix Suffix ka rating EE Number E1 NEMA 1/3r/12/4 N kA per phase SPD100 4X NEMA 4X P kA per phase SPD150 4S NEMA 4X SS P kA per phase SPD200 FM Flushmount L up to 200kA only kA per phase SPD250 P1 Pullbox kA per phase SPD kA per phase SPD kA per phase kA per phase kA per phase kA per phase kA per phase - 1K 1000kA per phase -
4 APT Continued Voltage codes APT Codes Description EE Codes 1 Split-phase - 3 wire + g - 120/240V 240S Model Information 11 Single Phase - 2 wire + g - 120V - TE Series - External Mount (Modular) ka per Phase Eaton Electrical Model 12 Single Phase - 2 wire + g - 230V 230L XCS 100 CVX Three phase Wye - 4 wire + g - 120/208V 208Y XDS SPD Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H How to read APT part number: TE 6 XCS 15 E1 Series Voltage Model ka Rating Enclosure code # 4 Three phase Wye - 4 wire + g - 277/480V 480Y 5 Three phase Delta - 3 wire + g - 480V 480D 6 Three phase Delta - 3 wire + g - 240V 240D 7 Three phase Wye - 4 wire + g - 220/380V 400Y 8 Three phase Wye - 4 wire + g - 347/600V 600Y 9 Three phase Delta - 3 wire + g - 600V 600D Suffix Description EE Suffix A Audible Alarm 2 E Remote Display - 2 Type 2 SPD with cul 2,3 Suffix ka rating EE Number kA per phase SPD kA per phase SPD kA per phase SPD200
5 APT Continued Voltage codes APT Codes Description EE Codes 1 Split-phase - 3 wire + g - 120/240V 240S Model Information 11 Single Phase - 2 wire + g - 120V - TE Series - External Mount (Modular) ka per Phase Eaton Electrical Model 12 Single Phase - 2 wire + g - 230V 230L XGA 160 SPD160.2K 2 Three phase Wye - 4 wire + g - 120/208V 208Y How to read APT part number: TE 6 XGA /240 /FM Series Voltage Model Options Options 3 Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H 4 Three phase Wye - 4 wire + g - 277/480V 480Y 5 Three phase Delta - 3 wire + g - 480V 480D 6 Three phase Delta - 3 wire + g - 240V 240D 7 Three phase Wye - 4 wire + g - 220/380V 400Y 8 Three phase Wye - 4 wire + g - 347/600V 600Y 9 Three phase Delta - 3 wire + g - 600V 600D Suffix Description EE Suffix / Ka Option SPD250 / ka SAD - / ka SAD - / kA SAD - /DC dry contacts 2 /SC surge counter 3 /2S dual counters - /12 NEMA 12 N /3R NEMA 3R N /04 NEMA 4 N /FM Flushmount L /4X NEMA 4X P /4S NEMA 4X stainless steel P /TN NEMA1/12/3R/4 N
6 APT Continued Model Information SPDee Series - External Mount (Modular) ka per Phase Eaton Electrical Model S50A120V2P 50 CVX S S50A120V3Y 50 CVX Y S50A127V3Y 50 CVX Y S50A220V1P 50 CVX L S50A220V3Y 50 CVX Y S50A240V3H 50 CVX D S50A240V1P 50 CVX L S50A240V3D 50 CVX D S50A277V1P 50 CVX L S50A277V3Y 50 CVX Y S50A480V3D 50 CVX D S50A480V3H 50 CVX D S100A240V2P 51 CVX S
7 Voltage codes CT Competitor Make: Current Technology Codes Description EE Codes Competitor Web: 120/240-2G Split-phase - 3 wire + g - 120/240V 240S 120/208-3GY Three phase Wye - 4 wire + g - 120/208V 208Y Model Information 220/380-3GY Three phase Wye - 4 wire + g - 220/380V 400Y Select Compact Series ka per Phase Eaton Electrical Model 277/480-3GY Three phase Wye - 4 wire + g - 277/480V 480Y SELc SPD120..N 347/600-3GY Three phase Wye - 4 wire + g - 347/600V 600Y SELc SPD160..N 120/240-3GHD Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H 240-3GD Three phase Delta - 3 wire + g - 240V 240D Select 2 Series ka per Phase Eaton Electrical Model 480-3GD Three phase Delta - 3 wire + g - 480V 480D SEL GD Three phase Delta - 3 wire + g - 600V 600D SEL SEL SPD400..N Disconnect & Diagnostics Options SEL SPD300..N Suffix Description EE Suffix SEL SPD200..N -D NEMA 1 With Disconnect Switch M NEMA 4X with Disconnect Switch TransGuard Series ka per Phase Eaton Electrical Model NEMA 4 with Disconnect Switch O TG L1 Primary Monitoring 2 TG L2 Advanced Monitoring 3 TG SPD400..N -L3 MasterMIND Monitoring - TG SPD300..N -M Metal all metal TG SPD250..N -S Stainless P TG SPD200..N TG SPD160..N TG SPD120..N SF Suppression Filter System ka per Phase Eaton Electrical Model SF SF SF Notes: 1) NEMA 4/12 is a standard offering. SF SPD ) SEL & SF models are selenium base TVSS SF SPD ) For DTS-2 or Hand-Held Tester - Contact factory. SF SPD SF SPD SF SPD SF SPD How to read CT part number: SL /600-3GY L1 D Model ka per Voltage Option Other # mode code Options Q
8 Voltage codes CT Current Technology Continued Codes Description EE Codes 120/240-2G Split-phase - 3 wire + g - 120/240V 240S Model Information 120/208-3GY Three phase Wye - 4 wire + g - 120/208V 208Y CurrentGuard Series ka per Phase Eaton Electrical Model 220/380-3GY Three phase Wye - 4 wire + g - 220/380V 400Y CG80 - (voltage code) 160 SPD160 (Standard) 277/480-3GY Three phase Wye - 4 wire + g - 277/480V 480Y CG60 - (voltage code) 120 SPD120 (Standard) 347/600-3GY Three phase Wye - 4 wire + g - 347/600V 600Y CG40 - (voltage code) 80 SPD100 (Standard) 120/240-3GHD Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H 240-3DG Three phase Delta - 3 wire + g - 240V 240D CurrentGuard Plus Series (surge counter) ka per Phase Eaton Electrical Model 380-3DG Three phase Delta - 3 wire + g - 380V N/A CGP200 - (voltage code) 400 SPD400..(Counter) 480-3DG Three phase Delta - 3 wire + g - 480V 480D CGP150 - (voltage code) 300 SPD300..(Counter) 600-3DG Three phase Delta - 3 wire + g - 600V 600D CGP100 - (voltage code) 200 SPD200..(Counter) CGP80 - (voltage code) 160 SPD160..(Counter) CGP60 - (voltage code) 120 SPD120..(Counter) CurrentGuard Compact Series ka per Phase Eaton Electrical Model CGC /480-3GY 100 SPD100480Y2N CGC /208-3GY 100 SPD100208Y2N CGC /240-2G 100 SPD100240S2N CG / CGP / CGC Models TransEnd Series *See Note* ka per Phase Eaton Electrical Model Notes: 1) NEMA 4 enclosure is standard. N XN100 - (voltage code) 200 SPD200.2N XN75 - (voltage code) 150 SPD160.2N XN50 - (voltage code) 100 SPD100.2N TransEnd Models XN25 - (voltage code) 50 SPD050.2N Notes: 1) NEMA 4 enclosure is standard. How to read CT part number: CGP /240-2G Model Voltage Code EE Codes
9 Surgitron ll Competitor Make: Joslyn Competitor Web: SPD100.2K Model Information SPD050240S2K Surgitron l SPD100240H2K SPD050208Y2K SPD050480Y2K SPD100240S2K SPD050400Y2K SPD100240S2K Eaton Electrical Model MN SPD200240S2K Surgitron lll Eaton Electrical Model SPD100.2K SPD100220Y2K SPD100240D2K SPD100480D2K SPD050.2K SPD100240H2K SPD100240H2K SPD050.2K SPD100208Y2K SPD050240S2K SPD100208Y2K SPD050240S2K SPD100208Y2K SPD100240H2K MN SPD200208Y2K SPD100240H2K SPD100480Y2K SPD050480D2K SPD100480Y2K SPD050208Y2K SPD120480Y2K SPD050208Y2K L SPD200480Y2K SPD050480Y2K MN SPD200480Y2K SPD050480Y2K SPD100400Y2K SPD050400Y2K SPD100400Y2K SPD050400Y2K Surgitron PM PM SPD160.2K PM SPD160240S3K PM SPD160240H3K PM SPD160208Y3K PM SPD160480Y3K PM SPD160400Y3K 1) Models ending as -45, exclude Form "C" 2) Models ending as -4X, Includes NEMA 4X - stainless steel enclosure 3) Models ending as -S, Includes Surge Counter 4) Model is a Remote Monitor & Alarm
10 Competitor Make: Siemens Continued Eaton Electrical Model ka/phase Competitor Web: TPS x SPD160.2N 160 TPS x SPD120.2N 120 Model Information Sentron TPS models ka per Phase Eaton Electrical Model Voltage codes TPS SPD080.2C Siemens TPS SPD160.2C Codes Description EE Codes TPS x SPD120.2C A Split-phase - 3 wire + g - 120/240V 240S TPS x SPD160.2C B Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H TPS x SPD100.2C C Three phase Wye - 4 wire + g - 120/208V 208Y TPS x SPD160.2C D Three phase Delta - 3 wire + g - 240V 240D TPS x SPD200.2C E Three phase Wye - 4 wire + g - 277/480V 480Y TPS x SPD250.2C F Three phase Delta - 3 wire + g - 480V 480D TPS x SPD100.2C G Three phase Delta - 3 wire + g - 600V 600D TPS x SPD160.2C K Three phase Wye - 4 wire + g - 220/380V 400Y TPS x SPD200.2C L Three phase Wye - 4 wire + g - 347/600V 600Y TPS x SPD250.2C TPS x SPD160.2C Diagnostics Options TPS x SPD160.2C Suffix Description EE Suffix TPS x SPD200.2C X Surge Counter 3 TPS x SPD250.2C R Remote Monitor - Contact factory - TPS x SPD200.2C Z Surge Counter & Remote Monitor - Contact Factory - TPS x SPD250.2C TPS x SPD300.2C Notes: 1) x - Represents Voltage code TPS x SPD400.2C 2) Product # - Determines application (Paneboard, TPS x SPD400.2C Switchboard, Switchgear, Bus-plug) TPS x SPD100.2B TPS x SPD160.2B How to read Siemens part number: TPS x SPD200.2B TPS x SPD250.2B TPS E X R TPS x SPD200.2B TPS x SPD250.2B Model Voltage Product Surge Option Other TPS x SPD300.2B # Code # Current Option TPS x SPD400.2B TPS x TPS x SPD400.2B SPD TPS x TPS x SPD SPD OR- TPS 080 A X R TPS x SPD Model Surge Voltage Option Other TPS x SPD050.2N # Current Code Option TPS x SPD080.2N TPS x SPD250.2N
11 Competitor Make: Square D Voltage codes Competitor Web: Sq D Codes Description EE Codes Model Information 1 Split-phase - 3 wire + g - 120/240V 240S EMA Series ka per Phase Eaton Electrical Model 2 Three phase Wye - 4 wire + g - 120/208V 208Y TVS x EMA12 x 120 SPD Three phase Hi-Leg Delta - 4 wire + g - 120/240V 240H TVS x EMA16 x 160 SPD Three phase Wye - 4 wire + g - 277/480V 480Y TVS x EMA24 x 240 SPD Three phase Delta - 3 wire + g - 480V 480D TVS x EMA32 x 320 SPD Three phase Delta - 3 wire + g - 240V 240D TVS x EMA48 x 480 SPD Three phase Wye - 4 wire + g - 220/380V 400Y 8 Three phase Wye - 4 wire + g - 347/600V 600Y EBA Series ka per Phase Eaton Electrical Model 9 Three phase Delta - 3 wire + g - 600V 600D TVS x EBA12 x 120 SPD120. TVS x EBA16 x 160 SPD160. Disconnect & Diagnostics Options TVS x EBA24 x 240 SPD250. Suffix Description EE Suffix S Surge Counter 3 HWA Series ka per Phase Eaton Electrical Model D Dry Contacts 2 TVS x HWA12 x 50 SPD050. M Remote Monitor & Dry Contacts - TVS x HWA16 x 80 SPD080. I NEMA 1/3R With Disconnect Switch M TVS x HWA24 x 120 SPD120. NEMA 4X with Disconnect Switch Q NEMA 12 with Disconnect Switch O XF, XP, XT Series ka per Phase Eaton Electrical Model AA Audible Alarm 2 TVS x XF 50 x 50 SPD050. A NEMA 1/3R K TVS x XF 80 x 80 SPD080. F NEMA 1 Flushmount L TVS x XP 50 x 50 SPD050. R NEMA 1/3R K TVS x XP 80 x 80 SPD080. NEMA 12 N TVS x XT 12 x 120 SPD Contact factory N TVS x XT 16 x 160 SPD160. X NEMA 4X P TVS x XT 24 x 240 SPD250. Notes: XR, XW Series ka per Phase Eaton Electrical Model 1) XGA is a modular TVSS. TVS120XR40 x 40 CVX S 2) Conductor level fusing. TVS230XR40 x 40 CVX S TVS x XW100C 100 CVX100-. XGA Series ka per Phase Eaton Electrical Model TVS x XGA 16 x 160 SPD160. TVS x XGA 24 x 240 SPD250. SDSA Series ka per Phase Eaton Electrical Model SDSA SP1-240S SDSA SP1-. How to read Square D part number: TVS 2 XP 50 F Model Voltage Series ka per Enclosure # Code # Phase Type
UL rd Edition SPD
TPS3 09 Type 1 Surge Protective Device (SPD) Mounts External to Electrical Distribution Equipment or Internal to P1, P2 Lighting Panelboards, P3 Power Panelboards and Busway Systems Features: UL 1449 3rd
More informationWAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)
WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More informationFDM Medium Voltage Controller
1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller
More informationPower-Sure 700. Technical Data TD158001EN. Contents
Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...
More informationSECTION DISTRIBUTION SWITCHBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 11 SPEC WRITER NOTES: Use this section only for NCA projects. Delete between // -- // if not applicable to project. Also delete any other item or paragraph
More informationULTRA-K Series 600K - he
5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems
More informationS10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product
More informationPOWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.
POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationUBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS
More informationDesign Specifications Low Voltage Active Harmonic Filter
Design Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description, warranty
More informationAmpgard The name motor applications rely on
Medium-voltage motor control The name motor applications rely on Oil and gas Mining Water/wastewater Pulp and paper Utility A legacy of reliability for more than 4 decades 1950 1960 1970 1980* 1990 2000
More informationJefferson Electric Inc Product Catalog JE901
Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich
More informationHarmonic mitigating transformers. Energy savings through harmonic mitigation
Harmonic mitigating transformers Energy savings through harmonic mitigation Harmonic mitigating transformers Today s issues and needs Eaton s Harmonic Mitigating Transformer (HMT) As our world becomes
More informationInfraStruXure Manager v4.x Addendum: Building Management System Integration
InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System
More informationMotilal Nehru National Institute of Technology Allahabad - (AL) Fluids Engineering - (FE) G
CCMT 2012 Cutoff List of First Round GATE Score Cutoff National Institute of Technology Agartala - (AG) Geotechnical Engineering - (GE) G1 367 330 256 National Institute of Technology Agartala - (AG) Structural
More information4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards
ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling
More informationLow Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned
Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design
More informationPREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!
PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling
More informationHarmonic mitigating transformers. Energy savings through harmonic mitigation
Harmonic mitigating transformers Energy savings through harmonic mitigation Harmonic mitigating transformers Today s issues and needs Eaton s harmonic mitigating transformer (HMT) As our world becomes
More information2.1. Product Description
.1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................
More informationPANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer
PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient
More informationAPQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute
More informationZT 20xx IOG SERIES. Quick Start 1 What s in the Shipping Package? ANT
ZT 20xx IOG SERIES Quick Start 1 What s in the Shipping Package? The shipping package contains the following items: ZT 20xx IOG Module ANT 124 05 Quick Start If any of these items are missing or damaged,
More informationCCMT 2012 Cutoff List of 4th Round
CCMT 2012 Cut-Off List of 4th round GATE Score Cutoff National Institute of Technology Agartala - (AG) Geotechnical Engineering - (GE) G1 322 281 190 National Institute of Technology Agartala - (AG) Structural
More informationEnergizing a world that demands more
Industrial Controls Division (ICD) Line card Industrial Control Division Headquarters W126 N7250 Flint Drive Menomonee Falls, WI 53051 Energizing a world that demands more Eaton s industrial control portfolio
More informationEE Lecture 14 Wed Feb 8, 2017
EE 5223 - Lecture 14 Wed Feb 8, 2017 Ongoing List of Topics: URL: http://www.ece.mtu.edu/faculty/bamork/ee5223/index.htm Labs - EE5224 Lab 3 - begins on Tues Feb 14th Term Project - details posted. Limit
More informationTOSHIBA International Corp
TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification
More informationP. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX
SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations
More information3RA13, 3RA14 Contactor Assemblies
RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard
More informationSECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL
PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.
More informationPower Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers
Power Quality 13 Answering Today s Power Challenges Jefferson Electric is continually updating its product line to remain on the forefront of transformer technology. Electrical harmonics have become a
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationGeneral Purpose Transformers
Transformers General Purpose Transformers Standard Units 1P 480 x 240V Primary, 120/240V Secondary.25 1D1N205.50 1D1N505.75 1D1N705 1.0 1D1N001 1.5 1D1N105 2.0 1D1N002 3.0 1D1N003 5.0 1D1N005 7.5 1D1N007
More informationHeavy Duty Safety Switches
eavy uty Safety Switches 240 Volt Class 110 Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety
More informationDescription & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...
SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make
More informationDistribution/Substation Transformer
Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More information2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description
Distribution.5 Contents Description Motor Drive Isolation............ Mini Power Centers Standards and Certifications............... Catalog Number Selection................ Product Selection.......................
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller
More information6.5. Power Pedestals... Contents Description. Firehouse. Marina Power and Lighting Equipment
Power Pedestals.5 Contents Power Pedestals........................... Lighthouse............................... Lighthouse SS............................ Admiral SS............................... Newport
More informationD E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter
Magnetostrictive Transmitters D E S C R I P T I O N The Enhanced Jupiter Magnetostrictive level transmitter provides a 4 20 ma output proportional to the level being measured or FOUNDATION fieldbus output.
More informationINTELLIMETER REGISTER
INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products
More informationMotor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87
Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................
More informationStraight Isolation - Plug In (171 Series)
Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested
More informationAssembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU
Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level
More informationINTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers
INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency
More information5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts
ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits
More informationIndustrial Electrician Level 3
Industrial Electrician Level 3 Industrial Electrician Unit: C1 Industrial Electrical Code I Level: Three Duration: 77 hours Theory: Practical: 77 hours 0 hours Overview: This unit is designed to provide
More informationP48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 P48G11S05P 5KVA 1PH 480V - 10/40V Mini Power Center Eaton Corp Catalog Number Manufacturer Description Weight per unit
More informationTerminal blocks Index
Terminal Index - Terminal SNK terminal....1.72 General information Features and benefits...1 -.3...4 Marking solutions...5 Panorama...6 -.7 Ordering details ZS4 Screw terminal...8 ZS6 Screw terminal...9
More information(2) New Standard IEEE P (3) Core : (4) Windings :
(d) Electrical characteristics (such as short-circuit withstand, commutating reactance, more number of windings, etc); (e) Longer life expectancy; (f) Energy efficiency; (g) more demanding environment.
More informationGENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS
GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find
More informationTitle: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 4.0 Sectionalizer Construction... 4 5.0 Mechanism... 6 6.0 Solid Dielectric
More informationPCTS Series. Power Capacitor Test System. Applications: Testing Applications: Benefit and Advantage: and IEC
PCTS Series Power Capacitor Test System Applications: 12kV/2500kVar and Below Dry and Oil Filled Power Capacitor (Samgor also can special design for customer.) Testing Applications: Capacitance and Tan
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationModelling Parameters. Affect on DER Impact Study Results
Modelling Parameters Affect on DER Impact Study Results Agenda Distributed Energy Resources (DER) Impact Studies DER Challenge Study Steps Lessons Learned Modeling Reverse Power Transformer Configuration
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More informationWye or Delta Systems DS9181 (CSA Approved)
6- High-resistance Grounding Equipment Wye or Delta Systems DS98 (CSA Approved) 0, 0, 600 Volts WHERE TO USE The function of a high-resistance grounding equipment is:. To provide a ground for neutral of
More informationVariable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
More informationManual Sanding Stiff Flexible
Manual Sanding Premium KA165 KA164 Standard KA161 KA162 Basic KA169 Stiff Flexible Stiffness X wt XJ wt JX wt J wt JJwt Backing Cotton Cotton Cotton Cotton Grain Coating KA169 _ Handy Roll KA161 _ Handy
More informationAC GHZ DISTRIBUTION AND TRUNK AMPLIFIER
30.11.2015 1(7) 2500 1.2 GHZ DISTRIBUTION AND TRUNK AMPLIFIER The 2500 is a dual active output amplifier with 2 x 43 operational. This product can be used as high distribution amplifier, but also as a
More information2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers
.5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings
More information2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards
Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped
More informationSIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A
The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance
More informationREPLACING ACC7B WITH CAT2
TN-18 TECHNICAL NOTES REPLACING WITH Overview Model is a preamplifier that allows interfacing between low level turbine flow meter signal and digital electronics. The output signal is a square wave logic
More informationThe NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:
Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationUtility Interconnection and System Protection
Utility Interconnection and System Protection Alex Steselboim President, Advanced Power Technologies, Inc. Utility paralleling vs. isolated operation. Isochronous kw load sharing Reactive power (VAR) sharing
More information11/0 IZM circuit-breakers, IN switch-disconnectors
11/0 IZM circuit-breakers, IN switch-disconnectors Contents IZM circuit-breakers, IN switch-disconnectors 11/1 from 630 A 6300 A Page Description 11/2 Technical overview 11/4 Overview of functions for
More informationSolid-State Switching Devices
SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching
More informationInstallation requirements
Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and
More informationModel 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents
Model 0-MMPC-L Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 877 Aurora Road Quick Start Guide Cleveland, Ohio 9-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments Model
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n
More informationDMM Technology Corp. DYN AC Servo Drive CAN Specification [DYNCAN1-BL314-12A] Document Version 1.2A Published March 20, 2018
DMM Technology Corp. DYN AC Servo Drive CAN Specification [DYNCAN1-BL314-12A] Document Version 1.2A Published March 20, 2018 March 20, 2017 Version 1.2 1. Overview The DYN servo drive follow standard CAN2.0A
More informationGen Purpose Wiring Devices - Gen Purpose Recept & Surge Prot
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VGFD20A 20A Alm Gfci RCPT Eaton Wiring Devices Catalog Number VGFD20A Manufacturer Eaton Wiring Devices Description Circuit
More informationBECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG
PRODUCT CATALOG M O T O R & G E N E R A T O R P R O T E C T I O N BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG Why Your Equipment Needs MEG-ALERT Protection 1 2 3 4 5 6 7 How can you be sure
More informationHAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationSafety when it matters the most! Electrical Installation A to Z. Maximum Retail Price w.e.f. 15 th February, Answers for infrastructure.
Safety when it matters the most! Electrical Installation A to Z Maximum Retail Price w.e.f. 15 th February, 2010 Answers for infrastructure. s Index Sr. No. Items Pg. No. 1. Minigard 3kA MCBs, Type 5SQ
More informationResidual Current Operated Circuit-Breakers (RCCBs)
Product overview Residual Current Operated C ircuit-breakers (RCCBs) Number of poles Rated fault current I n ma Rated current I n A MW Auxiliary switches can be mounted (Type A) (Type B) 5SM1and 5SM3 RCCBs
More informationCONTROL MANUAL. Dry-Pic 09PE - 09VE
CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth
More information10. PARTS LIST RPM ELEVATING ASSEMBLY ( Ⅰ ) - FANUC ELEVATING ASSEMBLY DEAWING 10-1
10. PARTS LIST 10.1 8000RPM ELEVATING ASSEMBLY ( Ⅰ ) - FANUC 10.1.1 ELEVATING ASSEMBLY DEAWING 10-1 10.1.2 8000RPM ELEVANTING ASSEMBLY PARTS LIST ( Ⅰ ) - FANUC NO. PART NO. DESCRIPTION QTY 1. 3.5TON 13
More informationDISCRETE INPUT MODULE, 16 points
INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More information60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES
60K(i) - 260K(i) THREE PHASE SureImage IMAGING & TREATMENT SERIES Power Conditioner MODEL ULTRA-K/M THREE PHASE ISOLATION TRANSFORMER Power Processor MODEL 700F/M THREE PHASE VOLTAGE REGULATOR, WITH ISOLATION
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More informationEE Lecture 15 (recorded Feb 9, 2011) Fri Feb 15, 2013
EE 5223 - Lecture 15 (recorded Feb 9, 2011) Fri Feb 15, 2013 Ongoing List of Topics: URL: http://www.ece.mtu.edu/faculty/bamork/ee5223/index.htm Term Project - structuring, details Exercises posted Today:
More informationP o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.
P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched
More informationZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP
Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO:
More informationAND 7600.
* * ENGINEERING CODEBOOK * * THROUGH THE USE OF THIS CATALOG ALL THE COMPONENT PARTS OF ANY PERMCO PUMP OR MOTOR CAN BE DETERMINED EXCLUDING FASTENERS. THE FOLLOWING SERIES ARE INCLUDED: 1500 197 2100
More informationSingle Channel Protector in an SOT-23 Package ADG465
a Single Channel Protector in an SOT-23 Package FEATURES Fault and Overvoltage Protection up to 40 V Signal Paths Open Circuit with Power Off Signal Path Resistance of R ON with Power On 44 V Supply Maximum
More informationAUDIO SIGNAL CONVERTER
MillMinder AUDIO SIGNAL CONVERTER IM-1 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com CATALOG NUMBERING SYSTEM MILLMINDER 9 0
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................
More informationLDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.
LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes
More informationCondition Monitoring Custom Products
CMCP500 Series Transmitters/Monitors Low Cost Din rail mount 4-20 ma output Sensor fault detection Buffered transducer output Optional filters Alert, Danger & OK Alarms and Relays Trip Multiply Remote
More informationAEROCONNECT 1B NA C Control manual
AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication
More informationGas-Insulated Medium-Voltage Switchgear siemens.com/8dab12
8DB 12 blue GIS Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12 Features Gas-insulated switchgear (GIS) type 8D/B has been an integral part of the medium-voltage portfolio at Siemens for more
More informationSL Series Slot Sensor
Self-contained opposed-mode sensor pair Features An easy-to-use self-contained opposed-mode sensor pair in a rugged U-shaped housing Easy and economical to mount Molded-in beam guides simplify mounting
More information