Phase 1. GVS Fail safe isolator. ELCB MCB/ Fuse. thermostat at 65⁰C. Slave Control Cables SSR2. for Immersion. Live Only

Size: px
Start display at page:

Download "Phase 1. GVS Fail safe isolator. ELCB MCB/ Fuse. thermostat at 65⁰C. Slave Control Cables SSR2. for Immersion. Live Only"

Transcription

1 Wireless connection CYOZ 0.75mm 2 core Screened Control cable Mains cable Phase 1 Renewable Generators Distribution Board Phase 1 AC Isolator GVS Fail safe isolator ELCB MCB/ Fuse Din Rail. ACVT vAC step down Transmer Control Cable from EMMA to Throttle Inverter DC AC MGCT Correctly Sized Fused Breaker HHCT 24v AC Henley Block Comms Cables Meter Box Cylinder 1 24v AC Mains L1 Clamp-on thermostat or temperature sensor. Heat Store EMMA 4G Electric heaters thermostat at 65⁰C. Slave Control Cables Isolation or Optional switchover set at lower temp than cut out by default. 3kW immersion SSR2 Controlled 0-3kW Variable Supply Electric heater thermostat at 65⁰C. 3kW immersion SSR1 Controlled SSR1 Live Only SSR2 Live Only Drawing No. TP45/135 Export Control Cascade Phase 1. Not to Service. SP15/45 with EC 12kW Single Phase. SP 15/45 Export Control Cascade.

2 Wireless connection CYOZ 0.75mm 2 core Screened Control cable Mains cable Phase 2 Renewable Generators Distribution Board Phase 1 AC Isolator GVS Fail safe isolator ELCB MCB/ Fuse Din Rail. ACVT vAC step down Transmer Control Cable from EMMA to Throttle Inverter DC AC MGCT Correctly Sized Fused Breaker HHCT 24v AC Henley Block Comms Cables Meter Box Cylinder 1 24v AC Mains L1 Clamp-on thermostat or temperature sensor. Heat Store EMMA 4G Electric heaters thermostat at 65⁰C. Slave Control Cables Isolation or Optional switchover set at lower temp than cut out by default. 3kW immersion SSR2 Controlled 0-3kW Variable Supply Electric heater thermostat at 65⁰C. 3kW immersion SSR1 Controlled SSR1 Live Only SSR2 Live Only Drawing No. TP45/135 Export Control Cascade Phase 2. Not to Service. SP15/45 with EC 12kW Single Phase. SP 15/45 Export Control Cascade.

3 Wireless connection CYOZ 0.75mm 2 core Screened Control cable Mains cable Phase 3 Renewable Generators Distribution Board Phase 1 AC Isolator GVS Fail safe isolator ELCB MCB/ Fuse Din Rail. ACVT vAC step down Transmer Control Cable from EMMA to Throttle Inverter DC AC MGCT Correctly Sized Fused Breaker HHCT 24v AC Henley Block Comms Cables Meter Box Cylinder 1 24v AC Mains L1 Clamp-on thermostat or temperature sensor. Heat Store EMMA 4G Electric heaters thermostat at 65⁰C. Slave Control Cables Isolation or Optional switchover set at lower temp than cut out by default. 3kW immersion SSR2 Controlled 0-3kW Variable Supply Electric heater thermostat at 65⁰C. 3kW immersion SSR1 Controlled SSR1 Live Only SSR2 Live Only Drawing No. TP45/135 Export Control Cascade Phase 3. Not to Service. SP15/45 with EC 12kW Single Phase. SP 15/45 Export Control Cascade.

4 Main Input E N L PHOENIX CONTACT DC OK STEP POWER Input AC VAC L(+) N(-) 2 Core Control Cable To Throttle Drawing No. EMMA 4G Control Hub. Not to Service. EMMA GVS Single phase with Resistive Heating Load.

5 Step 1 HHCT Wiring HHCT VDC V DC CMN 0 10V DC + Drawing No. SP15/75 GVS Cascade PV. Not to SP15/45 GVS Cascade

6 Step 2 MGCT Wiring MGCT VDC V DC CMN 0 10V DC + Drawing No. SP15/75 GVS Cascade PV. Not to SP15/45 GVS Cascade

7 Step 3 Temp Sensor Wiring Not Required on Large systems with Heater Batteries Temp Sensor 0-10V DC CMN 0 10V DC + Drawing No. SP15/75 GVS Cascade PV. Not to SP15/45 GVS Cascade

8 Step 4 Boost Button Wiring. Pre-Wired in Control Hub. Not Recommended on Large systems Boost Button 0-10V DC CMN 0 10V DC + Drawing No. SP15/75 GVS Cascade PV. Not to SP15/45 GVS Cascade

9 Step 5 AC Voltage Transducer Wiring ACVT + - PALADIN ACVT / V-AC V ~ V -- L N Fuse board/spur 240V AC Neutral 240V AC Live 0-10V DC CMN 0 10V DC + Drawing No. SP15/75 GVS Cascade PV. Not to SP15/45 GVS Cascade

10 Step 6 GVS Isolation Signal Wiring Triplacted across three phases Not supplied as standard by Cool Power Products For isolation of G59 Relay R3 24V AC Transmer THW 230V 24V L N V + - Isolation Signal Relay 24V 50Hz 60Hz SCHRACK BZ R3 2 R4 Isolation Signal Relay R4 Output from Transmer 24V to RLY CMN 1 on EMMA Controller Output from Transmer 24V + to on Isolation Signal Relay To Neutral Block To Transmer MCB To on Isolation Signal Relay 240V AC Neutral 240V AC Live 24V AC Neutral 24V AC Live Drawing No. Three Phase Isolation Schematic. Not to

11 Step 7 G59 Isolation Signal Wiring G59 Relay Not Supplied by Cool Power Products G59 Relay control Wiring Neutral G59 Relay control Wiring Live R3 R3 R3 24V 50Hz 60Hz 1 R3 2 R4 SCHRACK BZ Isolation Signal Relay L1 24V 50Hz 60Hz 1 R3 2 R4 SCHRACK BZ Isolation Signal Relay L2 24V 50Hz 60Hz 1 R3 2 R4 SCHRACK BZ Isolation Signal Relay L3 G59 Isolation Relay R4 R4 R4 Drawing No. Three Phase Isolation Schematic. Not to

12 Step 8 SSR1 4 Control Wiring from EMMA controller 0-10V DC CMN 0 10V DC + Output 40A Output 40A SSR SSR Input Input From EMMA SSR1 Control Output SSR1 From EMMA Controller CMN From EMMA SSR2 Control Output SSR2 From EMMA Controller CMN Shared CMN to SSR s 1-5 SSR2 Control Output + SSR1 Control Output + Drawing No. SSR Signal Voltage Control Wiring Not to Service. Control Wiring Of SSR1-4.

13 Step 9 SSR Wiring to Regulations may required a fused breaker between the SSR and each Immerison Earth Neutral 3kW Load Live IN Live Out Earth 120/240V~ Output SSR 50A 1 2 Input VDC V AC Neutral 240V AC Live DC CMN DC + Drawing No. SP15/75 GVS Cascade PV. Not to

14 Step 9 EMMA 4G Power Throttle Wiring 3kW Load 0-3kW Variable Supply EMMA 4G Power Throttle 240V AC Neutral 240V AC Live Earth Drawing No. SP15/30 GVS Cascade PV. Not to

15 Step J11 J3 J4 0-10V DC CMN 0 10V DC + Drawing No. SP15/30 GVS Cascade PV. Not to Service. EMMA GVS Single phase with Resistive Heating Load.

System Components and Accessories

System Components and Accessories OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit

More information

DPS Series 5W, 10W, 18W AC/DC DIN Rail Power Supplies

DPS Series 5W, 10W, 18W AC/DC DIN Rail Power Supplies DPS Series 5W, 1W, 18W AC/DC DI Rail Power Supplies AC - DC din rail mountable 5W, 1W and 18W class 2 power supplies E A R G U A R A T E E z U, cu, CE z Universal input 9~265VAC z High efficiency up to

More information

Phoenix Multi 12/1600/70 12/2500/120 24/1600/40 24/3000/70

Phoenix Multi 12/1600/70 12/2500/120 24/1600/40 24/3000/70 INSTALLATION MANUAL INSTALLATIEHANDLEIDING MANUEL D'INSTALLATION INSTALLATIONSANLEITUNG Phoenix Multi 12/1600/70 12/2500/120 24/1600/40 24/3000/70 GB NL F D Appendix Phoenix MultiPlus 12/2500/120 24/3000/70

More information

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets OPUS C OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets 6.6 OPUS C 220- OPUS C 220- Product Description Features OPUS C DC power systems are robust, free convection cooled, N+1 redundant

More information

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED. ERR MESSAGES: Click on Error for further detail MOT OVERCURRENT:THE PLATEN HAS BEEN MECHANICALLY RESISTED. MOT ERR: NO ENCODER MESSAGE TO THE MOT SPEED CONTROL IGNITION ERR: after the 4 th failed attempt

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Connecting Mains Electrical Power

Connecting Mains Electrical Power Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO-70308 REVISION AA CLEVELAND-KIDDER TENSION INDICATOR AO-70308 REVISION HISTORY Rev ECO Author Date Description of Change AA - - - CAD 07/28/2005

More information

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications Electrical Power Systems PSL2 Investigates the principles and operating characteristics of single-phase and three-phase power and distribution transformers Key Features Educational transformers with fully

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE 12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE 12.1 INTRODUCTION The range requirement in instrumentation ranges from a simple display of a single temperature value to multi sensor data acquisition

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Gutor PxW AC UPS Designed for North American Market

Gutor PxW AC UPS Designed for North American Market Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

SOLID STATE RELAY RATINGS

SOLID STATE RELAY RATINGS Solid State Relays SOLID STATE RELAY RATINGS PART NUMBER HPR48A25 HPR48A50 HPR48A75 3PSS60A75 HPR48D25 HPR48D50 HPR48D75 Rated operational current AC51 @ Ta=25 C 25 AMPS rms 50 AMPS rms 75 AMPS rms 75

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12 INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.

More information

Fault 514: communication error between the meter and the SH5K+

Fault 514: communication error between the meter and the SH5K+ Fault 514: communication error between the meter and the SH5K+ Fault 514 indicates that there is a communication error between the meter and the inverter. 1 Summary It is best to call us as soon as possible

More information

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Product Catalog PRODUCT CATALOG. Power supply system & test equipment Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:

More information

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems Product Catalog 2014 Condensed Version INNOVATIVE CIRCUIT TECHNOLOGY LTD. ICT has been providing DC power conversion products since 1986 for two-way wireless communications, fixed wireless broadband and

More information

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850

More information

ISOLATED AC/DC POWER SUPPLY

ISOLATED AC/DC POWER SUPPLY FEATURES IPS-2/24 Transformer isolation Selectable voltage outputs Thermal overload protected Fused outputs Snap track mounted APPLICATIONS AC power isolation Isolated DC power supply 2, 3 & 4 wire transmitter

More information

1-7. Product information Temperature Monitoring. Type: TMS U. Thermal control module:

1-7. Product information Temperature Monitoring. Type: TMS U. Thermal control module: - Basic information The electronic module protects, in combination with temperature sensors, the winding from electrical machines (motors, generators, transformers ) and liquid or gaseous media. Used properly,

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

Dale Power Solutions Ltd

Dale Power Solutions Ltd DC SWITCH TRIPPER CHARGER DATASHEET Features Erskine STU 110W Range 24V, 30V, or 48VDC nominal Constant voltage current limited charger output Standard alarms LCD voltmeter LED indica ons Equipped with

More information

400 (±2,5 V/ V/ ,3% V4A

400 (±2,5 V/ V/ ,3% V4A LVDT Inductive Position Transducer - Hydraulic Series Series Hydraulic position measurement in hydraulic cylinders of machine controls ranges 10...300 mm temperature -40...+150 C (sensors) 0...+60 C (external

More information

ELKOR MOC1 TRANSDUCER SET - MANUAL

ELKOR MOC1 TRANSDUCER SET - MANUAL ELKOR MOC1 TRANSDUCER SET - MANUAL Elkor MOC1 Power Transducer - Product Description The MOC1 true RMS 3 phase transducer is a micro-processor based metering product that provides a cost effective and

More information

Alternating Current Power

Alternating Current Power Chapter 4 Alternating Current Power MElec-Ch4-1 Overview What is Alternating Current AC Hazards AC Power Requirements Shoreside Utility System On-Board Generators MElec-Ch4-2 What is Alternating Current

More information

CT325 Miniature DC Temperature Controller

CT325 Miniature DC Temperature Controller CT325 Miniature DC Temperature Controller Overview The CT325 Miniature DC Temperature Controller is designed for use with Minco Thermofoil heaters and RTD or thermistor sensors. It offers inexpensive on/off

More information

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable

More information

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials. The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor

More information

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P AC semiconductor contactor Multi-function - 5 selectable modes of operation: Phase Angle, Distributed Full Cycle and Burst Control

More information

PID. What is PID and how does it work? Auto tuning PID with the 5400 Controller. Visit our website at:

PID. What is PID and how does it work? Auto tuning PID with the 5400 Controller. Visit our website at: PID What is PID and how does it work? Auto tuning PID with the 5400 Controller What is PID? PID control (pronounced P-eye-Dee) stands for Proportional-Integral-Derivative, and is a mathematical method

More information

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...

More information

NRGpilot E3000 Net Meter Installation Guide

NRGpilot E3000 Net Meter Installation Guide T E000 Net eter Installation Guide Introduction T uses two independent energy meters to monitor the power and energy flow from on-site generation and the grid. It uses these values to calculate power and

More information

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

FINAL - ET 60 - Electrician Theory Examination Marking Schedule FINAL - ET 60 - Electrician Theory Examination Marking Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions.

More information

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division MODULAR DC POWER SUPPLIES & SYSTEMS DC Power Systems DC/AC Inverters Static Switches DC/DC Converters GAMATRONIC, A SolarEdge Division 17 Hartom Street, Jerusalem 9777517, Israel 1-800-20-70-90 Tel: +972-2-5888277

More information

Industrial, 2-Pole ZS Type RA2A

Industrial, 2-Pole ZS Type RA2A Solid State Relays Industrial, 2-Pole ZS Type 2-Pole AC Solid State Relay Zero switching For resistive and inductive AC loads Direct copper bonding (DCB) technology LED indication Rated operational current:

More information

ENGINEERING THESISS ENG460

ENGINEERING THESISS ENG460 S Realization of a setup for educational experiments and safe investigations of PV Grid Connected system aspects Mohsan Khodadoost 2/12/2009 A report submitted to the School of Engineering and Energy,

More information

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. Its compact size, high efficiency, excellent reliability

More information

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting. Ready to use Single-Phase Relay: " Install it & Forget it!" Zero cross model : 7-28AC 5A back to back thyristors

More information

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing) X20092 DMFC36 Issue: 2 User manual Date: 31/10/14 Page: 1 of 10 KEY FEATURES Standard DIN Rail Mounting Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD

More information

4.3 Touchscreen User Manual

4.3 Touchscreen User Manual 4.3 Touchscreen User Manual Contents 1. Temperature 1. How do I adjust the temperature at console 2. How do I use the buttons on the sensor (Digital Sensor Only) 3. Sensor Symbols Explained (Digital Sensor

More information

PROGRAM CONTROLLER OUTLINE

PROGRAM CONTROLLER OUTLINE Specifications Sheet No.SPEC-1232E (1st Edition) EC1200A PROGRAM CONTROLLER OUTLINE The EC1200 can, totally and with high precision, control and monitor such factors as temperature, temperature balance

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

FRONIUS SMART METER APPLICATION GUIDE

FRONIUS SMART METER APPLICATION GUIDE FRONIUS SMART METER APPLICATION GUIDE An overview on how to use the Fronius Smart Meter under various scenarios in the field White Paper Fronius Australia Pty Ltd., BG Version 1.0/2017 Fronius reserves

More information

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting. AC Semiconductor Contactor pitch,5mm with Diagnostic compact size and DIN rail mounting. Ready to use SinglePhase Relay: " Install it & Forget it!" Zero cross model : 55VAC 5A back to back thyristors on

More information

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. : Order-No. : 7531 60 03 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions

More information

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply. LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into

More information

TRM-203/403 transformer resistance meters

TRM-203/403 transformer resistance meters TRM-203/403 transformer resistance meters Vanguard Instruments Company, Inc. www.vanguard-instruments.com TRM-203/TRM-403 transformer resistance meters Product Overview The TRM-203 and TRM-403 are three

More information

Product Range.

Product Range. Product Range www.energenie4u.co.uk Take control of your home Contents MiHome System Overview System Set Up MiHome App 4 6 8 Heating Range Thermostat Radiator Valves 30 32 34 Gateway Hand Controller Mains

More information

LK Wireless Room Control Cq

LK Wireless Room Control Cq LK Wireless Room Control Cq Description LK Wireless Room Control Cq consists of a LK Room Thermostat Cq-n (transmitter) and a LK Receiver Unit Cq 8 (8 channel receiver unit). The range also includes a

More information

Troubleshooting for Growatt TL&MTL. (Ver1.2)

Troubleshooting for Growatt TL&MTL. (Ver1.2) Troubleshooting for Growatt TL&MTL (Ver1.2) 2013-7-15 Version Date Note Ver1.1 2013.7.15 First draft Ver1.2 2013.7.29 Remove Hungary in Country code list table, Hungary choose VDE 0126 Content General...

More information

LabCon User Manual. Multi-Purpose Temperature Controller Temp High SP

LabCon User Manual. Multi-Purpose Temperature Controller Temp High SP LabCon Basic Multi-Purpose Temperature Controller 42.5 Temp High SP C 42.5 CONTENTS 1. FRONT PANEL LAYOUT 1 2. BASIC OPERATION 2 3. OPERATOR PARAMETERS 5 4. SUPERVISORY PARAMETERS 7 5. FACTORY PARAMETER

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

PV210. Why buy the PV210?

PV210. Why buy the PV210? The PV210 is a compact & cost effective I-V curve tracer that utilizes NFC technology, eliminating the need for a laptop on site. I-V curve tracing is made fast with simple push button operation; making

More information

Infinite Thermal Solutions Inc.

Infinite Thermal Solutions Inc. Page 1 ITSMT Series Temperature Controllers MT 48 VM Operating Manual Auto Tuning, Digital Electronic, DIN Sized Temperature Controllers US Easy Control Fuzzy + PID Run/Stop Operated on the Panel Multi-Input

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater For additional information contact matedev@outbackpower.com Page 1 of 20 Revision History Revision 2.0:

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

Hydraulic Valve Interface Products

Hydraulic Valve Interface Products Filename: Hydraulic Valve Interface Information.docx Date: 04/02/2014 Version: 2.0 Hydraulic Valve Interface Products Hydraulics provides a wonderful way of generating very large forces to move and control.

More information

MCTS II Multi Channel Current Transducer System. Installation Manual

MCTS II Multi Channel Current Transducer System. Installation Manual MCTS II Multi Channel Current Transducer System Installation Manual MA MCTS II, Ver. 1.0 1 10/2017 Contents 1. Introduction 2. Receiving of goods 3. Hardware Installation 3.1. Connection of the current

More information

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER H MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER SIMPLE ON-LINE RANGE SETTING (Using Actual Input Signal or Signal Generator) USER SETTABLE FULL SCALE FREQUENCY FROM 1 Hz to 25 KHz FOUR OUTPUT OPERATING

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models for resistive loads Low zero-cross turn-on voltage Input protection and control LED standard IP20 touch-proof flaps optional Connectors for power wiring and heat sinks

More information

Demonstration. Agenda

Demonstration. Agenda Demonstration Edward Lee 2009 Microchip Technology, Inc. 1 Agenda 1. Buck/Boost Board with Explorer 16 2. AC/DC Reference Design 3. Pure Sinewave Inverter Reference Design 4. Interleaved PFC Reference

More information

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual TE200S Solid State Relays Two-phase control of three-phase loads User manual Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission in any form or using any procedure

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

Conductivity Transmitter N-LF V AC

Conductivity Transmitter N-LF V AC OPERATING INSTRUCTIONS Conductivity Transmitter N-LF2000 230V AC These operating instructions apply to the following device: Article Measuring range Order number N-LF2000, Conductivity measuring device

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair

More information

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA 24.... 06/RA 44.... 08/RA 48.... 12 AC Solid State Relay Zero switching Direct copper bonding technology Rated operational current:, 2,

More information

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. Its compact size, high efficiency, excellent reliability together with easy

More information

02/11/2015

02/11/2015 Emergency stop and safety guard monitoring 2 channels KNE3-YS Part number 85102436 "Emergency stop" & "Safety gates monitoring" functions Single and 2-channel operation Security with redundancy and feedback

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

Remote Maintenance Box, RMB

Remote Maintenance Box, RMB OPERATOR S MANUAL Remote Maintenance Box, RMB Warnings and legal information Operating procedure Voltage measurement Document no.: 4189340730B SW version AGC 3.40.0 or later and AGC 4.00.0 or later Table

More information

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL This manual covers installation, setup, operation and troubleshooting. Read carefully before attempting to install, operate or service

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

RUN MAN OUT1 OUT2 FL40

RUN MAN OUT1 OUT2 FL40 MAN RUN OUT1 OUT2 FL40 Iso 5167 mass flow computer Installation and user manual rev. 12/2015 PRELIMINARY INFORMATION This document haves copyright reserved, C Arian. Referred trademarks are of property

More information

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC The SSR P Series Phase-Fired SCR Power Controllers 15-70 AMPS 80-600 VAC Phase-Fired SCR Power Controllers for resistive heating loads. ROBICON 1996 Rev. 12/96 Applications The SSR P series models are

More information

Licensed Electricians Practical Assessment (LEP)

Licensed Electricians Practical Assessment (LEP) Licensed Electricians Practical Assessment (LEP) Surname: Given Names: Date: Time: Location: Assessment Time (includes reading and preparation time): At the end of this time you will be asked to stop.

More information

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive Data Sheet Emotron FDU 2.0 Variable Speed Drive Electrical specifications related to model Table 1 Typical motor power at mains voltage 400 V Model Max. output current for 60 s [Arms] Normal duty (120%)

More information

SMARTRIPPLE Geyser Load Control Timer

SMARTRIPPLE Geyser Load Control Timer SMARTRIPPLE Geyser Load Control Timer Product description The ESCOTEK Geyser Load Control Timer, SmartRipple timer, will prevent hot water cylinders (geysers) from switching on during Eskom designated

More information

Disc Gap Control DGC-2. Technical Manual

Disc Gap Control DGC-2. Technical Manual GB Disc Gap Control DGC-2 Technical Manual Contents Introduction Electronic unit... 1 Tracer valve... 1 Technical data... 2 Component layout... 4 Functions, electronic unit Stepper motor operation...

More information

PID CONTROLLERS LT SERIES

PID CONTROLLERS LT SERIES PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4

More information

02/11/2015

02/11/2015 Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035 "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit

More information

IO-DIM4 4-Channel, Digital to Analogue Converters

IO-DIM4 4-Channel, Digital to Analogue Converters Page 1 of 5 IO-DIM4 4-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in) Page 19 Page 29 MODEL Dimensions K3TL 48 H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in) E5C2 48 H x 48 W x 86.7 D mm (1.89 x 1.89 x 3.41 in) Description & input and scale ranges Digital temperature display

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

Electronic fan speed regulators

Electronic fan speed regulators Electronic fan speed regulators Purpose The fan speed controller maintains the condensing pressure for fan-type condensers or fluid outlet temperatures for dry coolers, within prefixed values, for any

More information

ExamLearn.ie. Electricity in the Home & Electronics

ExamLearn.ie. Electricity in the Home & Electronics ExamLearn.ie Electricity in the Home & Electronics Electricity in the Home & Electronics Mains supply and safety The mains supply to the sockets in your house or school is at 230 V a.c. This voltage could

More information

Auto Tuning, Digital Electronic, DIN Sized

Auto Tuning, Digital Electronic, DIN Sized Page 1 ITSMT Series MT-48-V Operating Manual Auto Tuning, Digital Electronic, DIN Sized US Easy Control Fuzzy + PID Run/Stop Operated on the Panel Multi-Input K/J/RTD Selectable Auto Tuning Bias Value

More information

PV200. Why buy the PV200? The most compact I-V curve tracer around.

PV200. Why buy the PV200? The most compact I-V curve tracer around. The PV200 is a compact & cost effective I-V curve tracer that uses simple push button operation making it an efficient and versatile tester for PV systems. 999 datasets can be stored on the instrument

More information

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES 2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output

More information