This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

Size: px
Start display at page:

Download "This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials."

Transcription

1 The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials Astara. Rev January 2009 All rights reserved. Patent pending. Technical Support:

2 Usage The Astara I is a dimming interface for Nippo Seamlessline T6 fluorescent lamps with a dimmable ballast. The Astara I converts control signals from an external controller into a PWM signal that will dim or brighten the Seamlessline luminaire. The Astara I is compatible with a variety of external controllers, giving users and designers more flexibility in the control of lighting systems. The Astara I has inputs for three types of controllers: o High voltage dimmers o 0-10 VDC dimmers o Control stations using the RS-485 serial communication protocol This product is intended for use only with Seamlessline fixtures with the dimmable ballast option: SAL-UW850AM SAL-UW1000AM SAL-UW1250AM SAL-UW1500AM SAL-UW850CM SAL-UW1000CM SAL-UW1250CM SAL-UW1500CM 15 AMP FUSE SWITCHED LOAD GROUND LUG RELAY HIGH VOLTAGE INPUT/OUTPUT TERMINAL BLOCK 2 AMP FUSE CONTROL POWER SUPPLY RS-485 COMM RV VDC INPUT PWM OUTPUT RV2 DIP SWITCHES 2009 Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

3 Connections High Voltage Inputs/Outputs H1 Hot 1 (power input for the Astara I) S1 Switched Hot 1 (power output for Seamlessline ballast) N1 (two terminals) Neutral for Hot and Switched Hot inputs and outputs* N2 Neutral for Dimmed Hot () input* Dimmed Hot input for control when using a high voltage dimmer * Neutrals N1 and N2 are connected by default. When the Dimmed Hot input and Hot 1 input are a separate voltage or phase, N1 must be isolated from N2 by removing the jumper on JP5. Low Voltage Inputs/Outputs VDC - Input + - PWM (+) and (-) input for control when using a 0-10 VDC dimmer (+) and (-) output for PWM channel Communication & Peripheral Inputs TB5 Connector for RS-485 serial communication protocol Ground Ground Lug Connect the ground lug to earth ground TO EARTH GROUND Ground Lug Power from Distribution Panel 120 ~ 277VAC Input 60 Hz Neutral High Voltage Input Switched Hot H S Neutral 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Black White TB5 +1 S 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Black White PWM + PWM - -1 S PWM Control Signal Wires DO NOT CONNECT TO LINE VOLTAGE TO ADDITIONAL FIXTURES (25 MAX FOR 120V MODEL, 50 MAX FOR 277V MODEL) = 1 Twisted pair 18 AWG, 300 V shielded cable, max 330 feet Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

4 Astara I Installation Mounting Drill drywall screw Drill drywall screw Remove the cover and hold the Astara I in place, horizontally, against a wall. Drill two drywall screws through the holes as shown in the diagram above. High Voltage Ground Lug DO NOT MIX HIGH VOLTAGE AND LOW VOLTAGE IN THE SAME CONDUIT Low Voltage CONNECT TO EARTH GROUND Knockouts Side View All wiring for the Astara I can be routed through the two circular knockouts at each side of the enclosure. Do not run high-voltage wires and low-voltage wires through the same knockout or conduit. Conduits can be secured to the knockouts with a conduit fitting. Each side accepts 1/2" (using the singular knockout) or 3/4 (using the double knockout) conduits Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

5 Connecting Nippo Seamlessline Fixtures WARNING Shut off or disconnect main power before attempting the procedures below. To connect a Seamlessline fixture to the Astara I: 1. Connect 110, 120, 240, or 277 VAC to terminal H1. 2. Connect the neutral to one of the N1 terminals. 3. Connect S1 to the Seamlessline's power supply (black wire). 4. Connect the other N1 terminal to the Seamlessline's neutral (white wire). 5. Connect PWM (+) to the Seamlessline's purple wire. 6. Connect PWM (-) to the Seamlessline's gray wire. Power from Distribution Panel 120 ~ 277VAC Input 60 Hz High Voltage Input Neutral Switched Hot H 1 S 1 HIGH VOLTAGE INPUTS/OUTPUTS 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Green (Ground) Black (Hot) White (Neutral) 0-10 VDC INPUT PWM + PWM - = 1 Twisted pair 18 AWG, 300 V shielded cable, max 330 feet. PWM OUTPUT 2009 Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

6 Control Installation 0-10 VDC Dimmer Control Connecting a 0-10 VDC dimmer to the Astara I allows you to control the brightness of the fixtures from a typical 0-10 VDC control signal. To connect a 0-10 VDC dimmer: 1. Turn off power to the Astara I board and dimmer. 2. Connect the dimmer's positive output (typically a pink wire) to Connect the dimmer's ground (typically a gray wire) to Turn on the Astara I board and dimmer. 0-10VDC INPUT Power from Distribution Panel 120 ~277VAC Input 60 Hz High Voltage Input H 1 Neutral Switched Hot S 1 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Black White Black White S+ S- PWM Control Signal Wires DO NOT CONNECT TO LINE VOLTAGE TO ADDITIONAL FIXTURES (25 MAX FOR 120V MODEL, 50 MAX FOR 277V MODEL) PWM + PWM - = 1 Twisted pair 18 AWG, 300 V shielded cable, max 330 feet Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

7 High Voltage Dimmer Control Connecting a high-voltage dimmer to the Astara I allows you to control the brightness of the fixtures from a commercial grade 110 VAC, 120 VAC, 240 VAC, or 277 VAC incandescent wall dimmer or panelboard dimmer. Option 1: To connect a high-voltage incandescent wall dimmer 20 amp Circuit Breaker POWER FROM DISTRIBUTION PANEL 120 ~ 277 VAC input 60 Hz Neutral Dimmed output HIGH VOLTAGE INPUTS/OUTPUTS H1 S1 N1 N1 N2 INCANDESCENT WALL MER 120 VAC Switched Hot (S1) Neutral (N1) Ground Ground Lug NIPPO SEAMLESSLINE FIXTURE EARTH GROUND NIPPO SEAMLESSLINE FIXTURE PWM+ PWM- NIPPO SEAMLESSLINE FIXTURE Through wiring: up to 25 fixtures PWM OUTPUT 1. Turn off power to the Astara I unit and dimmer. 2. Connect the dimmer s dimmed output to of the Astara I. 3. Connect the constant hot circuit to H1 of the Astara I and the hot input of the wall dimmer. Use the same circuit to feed both H1 and the wall dimmer. H1(hot input) and (high voltage dimmer input) must be connected to the same voltage and phase. DO NOT MIX OR CONNECT TO SEPARATE VOLTAGES OR PHASES. DOING SO WILL DAMAGE THE. 4. Set dip switch SW3, #4 to ON if using a typical incandescent wall dimmer, or OFF if using a smart incandescent wall dimmer (see Appendix A). 5. Turn on the Astara I unit and wall dimmer Astara Rev 1.2 January 2009 All rights reserved. Patent pending. Technical Support:

8 High Voltage Dimmer Control Option 2: To connect a high-voltage incandescent architectural dimming system 20 amp Circuit Breaker Incandescent Dimming Module 120 ~ 277 VAC input 60 Hz HIGH VOLTAGE INPUTS/OUTPUTS H1 Neutral (N1) S1 N1 Neutral N1 MER RACK Ground Neutral (N2) Dimmed Output N2 120 VAC Switched Hot (S1) Neutral (N1) Ground Ground Lug NIPPO SEAMLESSLINE FIXTURE EARTH GROUND NIPPO SEAMLESSLINE FIXTURE PWM+ PWM- NIPPO SEAMLESSLINE FIXTURE Through wiring: up to 25 fixtures PWM OUTPUT 1. Turn off power to the Astara I and dimmer module in the dimming system. 2. Connect the dimmer s dimmed output to of Astara I. 3. Connect the dimmer s neutral to N2 of Astara I. H1(hot input) and (high voltage dimmer input) must be connected to the same voltage and phase. DO NOT MIX OR CONNECT TO SEPARATE VOLTAGES OR PHASES. DOING SO WILL DAMAGE THE. 4. Turn on the Astara I and dimmer module in the dimming system Astara Rev 1.2 January 2009 All rights reserved. Patent pending. Technical Support:

9 Control Installation RS-485 SERIAL COMMUNICATION The TB5 connector allows you to control the Astara I from the RC 4 controller. The RC 4 can adjust the brightness of the PWM channel and save light levels as presets, or scenes. To connect the RC 4: 1. Turn off power to the Astara I board. 2. Using a two-twisted pair, 20 gauge, shielded cable, connect the RC 4's terminal to the Astara I's terminal. 3. Connect the RC 4's S+ terminal to the Astara I's S+ terminal. 4. Connect the RC 4's S- terminal to the Astara I's S- terminal. 5. Connect the RC 4's -12 terminal to the Astara I's -12 terminal. 6. Connect the RC 4's shield terminal to the Astara I's shield terminal. 7. Turn on power to the Astara I board. RC 4 2 TWISTED PAIR 20 AWG 300 V SHIELDED CABLE MAX FEET TB5-12 SH Power from Distribution Panel 120 ~277VAC Input 60 Hz High Voltage Input Neutral Switched Hot S N 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Black White 1 TWISTED PAIR 18 AWG, 300V SHIELDED CABLE, MAX 330 FEET Black White S+ S- -12 SH TB5 PWM Control Signal Wires DO NOT CONNECT TO LINE VOLTAGE TO ADDITIONAL FIXTURES (25 MAX FOR 120V MODEL, 50 MAX FOR 277V MODEL) PWM + PWM Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

10 Appendix A: Dip Switches SW1 SW2 SW3 Sets the Astara's physical address on the RS-485 communication network (default is 0x00, or all ON) Switch 1: Adds 2% to the low-end cutoff light level Switch 2: Adds 4% to the low-end cutoff light level Switch 3: Adds 8% to the low-end cutoff light level Switch 4: Adds 16% to the low-end cutoff light level (default ON) Switch 1, 2, 3 not used. Switch 4 (default OFF-smart incandescent dimmer) Summary of Low-End Cutoff Light Level Settings Dip Switch H 1 S 1 ON COMMERCIAL GRADE INCANDESCENT WALL MER OFF SW 1 SW 2 SW 3 ON S+ S- -12 SH SMART INCANDESCENT WALL MER OFF OFF ON 2009 Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

11 Appendix B: Jumper Settings E1 JP1 JP2 JP3 JP4 1-2 closed: for use with source-type 0-10 VDC controllers 2-3 closed: for use with sink-type 0-10 VDC controllers (default setting) Factory setting: open (terminates the RS-485 serial communication channel when closed) Factory setting: open (resets the board when closed) Factory setting: closed (enables the watchdog timer when closed) Factory setting: open (ties the shield on the RS-485 serial communication input to ground when closed) JP5 Factory default: closed (ties the N1 and N2 neutrals together when closed, see page 6 for high voltage connections) H 1 S 1 JP5 JP2 JP1 S+ S- -12 SH JP3 JP4 E Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

12 Appendix C: System Status LEDs STATUS LED5 Blinks when the Astara I is powered on and running PW Indicates activity on PWM channel RS Blinks to indicate RS-485 serial communication HV Indicates use of high-voltage input 010 Indicates use of the 0-10 VDC input LED7 (+5V) Indicates presence of internal 5 VDC power supply LED8 (V) Indicates presence of internal 12 VDC power supply LED6 Indicates when the relay is closed (on) H 1 S 1 LED6 LED 6 STATUS LED 5 S+ S- -12 SH LED 7 LED 8 PW =PWM RS = RS-485 HV = High Voltage 010 = 0-10VDC LED5 PW RS LED7 LED Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

13 Appendix D: Adjustments RV1 RV2 Calibrates the 0-10 VDC input. The test point ADJ0-10V should read +5 VDC when +10 VDC is applied at the 0-10 VDC input. Calibrates the on-board +5 VDC reference. TP6 (test point 6, +5Vr) should read exactly +5 VDC. H 1 S 1 ADJ 0-10V S+ S- -12 SH TP6 RV Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

14 Appendix E: Relays and Fuses K1 F1 F2 Relay for switched hot output 1 (S1) 15A/120 VAC 6.5A/277 VAC Fuse for switched hot output 1 (S1) 15 A (120 VAC), 2 AG Fuse for hot input 1 (H1) and board power 2 A (277 VAC), 2 AG H 1 S 1 F1 F2 K1 S+ S- -12 SH 2009 Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

15 Appendix F: Technical Specifications Input voltage Internal power supply rating Switched hot output (S1) rating Max total input PWM control output rating Dimmed hot input Fuse ratings Relay rating Load type Enclosure dimensions Operating environment VAC, 50/60 Hz 2 A 15A/120 VAC, 6.5A/277 VAC (1800VA) 17 A 1 A VAC, 50/60 Hz 15A/120 VAC (F1) 2A/277 VAC (F2) 15A/120 VAC 6.5A/277 VAC Nippo Seamlessline fixtures with dimmable ballast 8 W x 4 H x 2 D For indoor use only Ambient temperature -30 F to 120 F Communication Wiring RS-485 High voltage wiring: AWG cable PWM output wiring: AWG shielded cable RS-485 wiring: Belden #9402 (2-twisted pair, shielded cable) 2009 Astara Rev January 2009 All rights reserved. Patent pending. Technical Support:

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. PD408-AN0-277 ANALOG 0-0 V 0-0V analog control 4 Channel x 2250 W Dimmer & Switch Packs 220/240/277 Volts operation PD408-AN0-277 4 circuit Analog -0V 4 x 8 A. Dimmer pack Serial Number Digital Lighting

More information

MILFORD INSTRUMENTS Limited

MILFORD INSTRUMENTS Limited MILFORD INSTRUMENTS Limited DMX Receiver (#1-497) Rev1.5 09/01/2007 The DMX receiver module is designed to provide 8 consecutive channels of output from a standard DMX protocol input signal. The outputs

More information

IB6 Series Solid-State Isolation Relay

IB6 Series Solid-State Isolation Relay IB6 Series Solid-State Isolation Relay Installation & Operation Manual TRANSDATA, INC. 2560 TARPLEY ROAD CARROLLTON, TEXAS 75006 TEL (972) 418-7717 FAX (972) 418-7774 Website: www.transdatainc.com E-mail:

More information

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev. , Inc. Eight Channel DMX Pack (includes information for -S) S S S S 4 8 USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is an 8-channel DMX- compatible dimmer pack. It contains three printed

More information

Plug power input. Socket power output

Plug power input. Socket power output Technical Data Sheet Rev issued 14. 10. 2005 DALI/DSI/ DMX to DimSlim PWM *1 This data sheet covers the general requirements for DimSlim fixtures when used in conjunction with the DALI/DSI/DMX to PWM Power

More information

Installing Fixture Using Remote Power Supply

Installing Fixture Using Remote Power Supply 2017 Edge Lighting. All Rights Reserved. 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.edgelighting.com info@edgelighting.com 904-BV2-2K4K-_03 BV2-1RE-_-2K4K-_ Installation

More information

AUDIO SIGNAL CONVERTER

AUDIO SIGNAL CONVERTER MillMinder AUDIO SIGNAL CONVERTER IM-1 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com CATALOG NUMBERING SYSTEM MILLMINDER 9 0

More information

5570M Series Intercom Installation and Operation Guide

5570M Series Intercom Installation and Operation Guide 5570M Series Intercom Installation and Operation Guide Isolated balanced/unbalanced lines Audio signals for the 5570M are transmitted over a wire pair using balanced line technology. An isolation transformer,

More information

PCA ECO lp Y, W T8 fluorescent lamps

PCA ECO lp Y, W T8 fluorescent lamps T8 PCA ECO lp Y, 58 W T8 fluorescent lamps Product description Processor-controlled ballast with y inside Noise-free precise control via DSI signal, switchdim or corridorfunction CELMA energy class A1

More information

INTELLIMETER REGISTER

INTELLIMETER REGISTER INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products

More information

Fibaro System Modules

Fibaro System Modules Chapter 3 Fibaro System Modules 3.1 Fibaro Dimmer FGD211 Figure 3.1: Dimmer module, FGD-211 Radio controlled light dimming module, designed to work with light sources of any type. May be connected to two-wire

More information

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2. diode led a division of elemental LED 24VDC COMMERCIAL GRADE 0-10V LED DIMMABLE DRIVER 24VDC WET LOCATION DIMMABLE SPECIFICATION SHEET OVERVIEW 24VDC Commercial Grade 0-10V Dimmable LED Drivers are essential

More information

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice. Instruction Manual Bypass Panels FRENIC-EcoPAK Fuji Electric Corp. of America FECA-IN-105 / 122010 Information subject to change without notice. Safety Precautions Read this manual thoroughly before proceeding

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps EXCE oneall series T8 PCA T8 EXCE oneall lp Y, 58 W T8 fluorescent lamps Product description Processor-controlled ballast with y inside oise-free precise control via DSI signal, switchdim, corridorfuctio

More information

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 Effective: June, 2000 LevelPRO Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 The information contained in this manual was accurate at the time of release. Specifications

More information

Variable Speed Brushed DC Motor Drive

Variable Speed Brushed DC Motor Drive The driving force of motor control & electronics cooling. Equinox: Variable Speed Brushed DC Motor Drive Navigator Equinox The Equinox variable speed brushed DC motor drive with Navigator Programmer is

More information

D2 Dimmer User s Manual Rev 0.3

D2 Dimmer User s Manual Rev 0.3 D2 Dimmer User s Manual Rev 0.3 2013 City Theatrical, Inc. SHoW DMX Transceivers are covered by U.S. Patent # 7,432,803 and other patents pending. 2 System Compliance Information...3 Safety Notices, Ratings

More information

Installation & Operation Manual

Installation & Operation Manual The eco-friendly solution to hard water SB-1200, SB-2000, SB-2800, SB-3600 & SB-4000 Installation & Operation Manual 10/13 Industrial Electronic Descaler 120/240 VAC (Auto Selected) Table of Contents Section

More information

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8 F ballasts E T8 PCA T8 EXCE oneall lp Y II, 18 58 W EXCE T8 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control

More information

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8 T8 PCA T8 ECO lp Y II, 18 58 W ECO T8 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal,

More information

Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor Occupant -1 02.01.06 Dual Technology Wall Mount Occupancy Sensor Models Available The Series wall-mount dual-technology sensors are used in spaces with pendant fixtures, ceiling fans, or high ceilings

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps EXCE series Product description Processor-controlled ballast with y inside oise-free precise control via DSI signal, switchdim, corridorfuctio or I I-MEMORY Extended I commands OEM-specific reserved memory

More information

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

The MP SERIES CONTROLLER. User s Manual. ISE, Inc. The MP SERIES CONTROLLER User s Manual ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://variac.com Form No, 003-1622 Rev G 02/25/2009 Form No. 003-1622

More information

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8 T8 PCA T8 ECO lp Y, x18 W and x18 W ECO T8 Product description Processor-controlled ballast with y inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal, switchdim

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5 T5 PCA T5 ECO lp Y, x1/ W and x1/ W ECO T5 Product description Processor-controlled ballast with y inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal, switchdim

More information

BOILER MANAGEMENT SYSTEM

BOILER MANAGEMENT SYSTEM Applicable to Serial Numbers 329985 and above (EPROM Rev. K and above) BOILER MANAGEMENT SYSTEM Table of Contents Boiler Management system (BMS) Page SECTION 1 ABOUT YOUR NEW BOILER MANAGEMENT SYSTEM (BMS)

More information

M O T O R M O D U L E

M O T O R M O D U L E HomeWorks Remote Power Modules (RPMs) are used in both centralised and hybrid system designs to control lighting, motor, and fan loads. There are several different models of RPMs; each model controls specific

More information

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm. Commercial System Design Guidelines Application Note 1. Introduction... 1 2. Determine the number of Modules/Inverters required.... 1 3. Determining the number of Microinverters per branch circuit... 1

More information

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications.

PRELIMINARY. S050W-054C1400-L03-UN-D2 50W Programmable Driver. Electrical Specifications. Protections. Environmental Specifications. Rev 2-23-217 Electrical Specifications Maximum Power: 5W Typical Efficiency: 87% Input Voltage Range: 12-277 Vac ± 1% Frequency: Power Factor: Inrush Current: Input Current (Max): 5/6 Hz >.9 @ 8-1% load,

More information

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5 T PCA T EXCITE lp Y, and x1/ W EXCITE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via DAI or DSI signal,

More information

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase The complete Liebert ITA2 MBC user manual is available at Vertiv s Web site, www.vertivco.com/en-us/products-catalog/critical-power/uninterruptible-powersupplies-ups/

More information

Maestro Local Lighting Controls

Maestro Local Lighting Controls L O C A L L I G H T I N G C O N T R O L S Maestro local lighting controls, function like standard dimmers and switches, but can be controlled as part of the whole-house lighting control system. Local lighting

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS! Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply Doc # 904-PSB-400W-24VDC_06 1718 W. Fullerton Chicago, IL 60614 Ph: 773.770.1195 Fax: 773.935.5613 www.pureedgelighting.com info@pureedgelighting.com

More information

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4. An American Control Electronics Brand PCM4 SERIES PCM4 USER MANUAL www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the PCM4 Series isolation card. This User Manual was created

More information

Digital Lighting Systems, Inc. PD402-DMX-RP. DMX512 4 x 300W Reverse Phase dimmer. DMX Address Hexadecimal = [ (S2 x 16) + S1 + 1 ]

Digital Lighting Systems, Inc. PD402-DMX-RP. DMX512 4 x 300W Reverse Phase dimmer. DMX Address Hexadecimal = [ (S2 x 16) + S1 + 1 ] , Inc. MX512 compatible our Channel immer or Switch Pack Reverse Phase 4 x 300 Watts @ 120 VAC MX512 4 x 300W Reverse Phase dimmer MX Address Hexadecimal = [ (S2 x 1) + S1 + 1 ] S2 S1 LOA Output sign wave

More information

DIMMER LOGIC. Rotary Wall-Mount LED Controller

DIMMER LOGIC. Rotary Wall-Mount LED Controller Rotary Wall-Mount LED Controller Coolon Dimmer Logic is the simplest wall-mount LED controller for architectural applications. Designed to complement Coolon s architectural LED fixture range with smooth

More information

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS GENERAL 1. To insure the success of the

More information

PHASED OUT. DALI interface terminals are provided to allow control and monitoring via a seperate controller.

PHASED OUT. DALI interface terminals are provided to allow control and monitoring via a seperate controller. Emergency lighting modules with DAI interface T, T, TC-DD, TC-F, TC- linear and compact lamps EM 00 V 0/0 Hz RoHS 0 0 Description: ow profile emergency lighting modules with DAI interface and automatic

More information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17 Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................

More information

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support PM-311x Quick Start Ver. 1.1 1. PM-311x introduction ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase

More information

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions Order-No. : 1135 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage

More information

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver Flow Detection MDS Integral or Remote Housing Microwave Doppler Switch Solids - Chute and Conveyor.525 GHz Sender Receiver FUNCTION Flow/no flow detection in solid material handling applications such as

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

Figure 1. DMC 60 components.

Figure 1. DMC 60 components. 1300 Henley Court Pullman, WA 99163 509.334.6306 www.digilentinc.com DMC 60 Reference Manual Revised November 15, 2016 This manual applies to the DMC 60 rev. A Overview The DMC 60 is an electronic speed

More information

EcoSystem 5-Series LED Driver 15 W to 75 W

EcoSystem 5-Series LED Driver 15 W to 75 W EcoSystem 5-Series LED Driver W to 75 W 369823d 1 11.17.14 EcoSystem 5-Series LED drivers provide a high performance solution for any space, in any application, while providing smooth, continuous dimming

More information

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES: PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 5 PIR OCCUPANCY SENSOR DESCRIPTION & OPERATION: These fixture mounted sensors provide multi-level control based on motion and/or daylight

More information

PROTOCOL WISH4 & WISH4-RP

PROTOCOL WISH4 & WISH4-RP & -RP Integrated Channel Dimming system -RP Triac dimmers x Amps. Reverse Phase dimmers x.5 Amps. USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is a self contained lighting controller

More information

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION INSTALLATION INSTRUCTIONS SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION This booklet contains information for wiring and installing the master station. All system wiring and remote station

More information

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B H765B, H766B, H7635B,C H7636B, H7655B, H7656B DUCT-MOUNT AND OUTDOOR-MOUNT HUMIDITY/ TEMPERATURE SENSORS INSTALLATI INSTRUCTIS APPLICATI The H76XXB Duct-Mount and H76XXC Outdoor-Mount Humidity/Temperature

More information

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing 90ENTRA EN_-LH9_. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is safety

More information

Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor LOS-WDT 1 11.04.08 Dual Technology Wall Mount Occupancy Sensor Models Available The wall-mount dual-technology sensors are used to control lighting in spaces that have pendant fixtures, ceiling fans, or

More information

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed ID 2000000000 185W Single Output Switching Power Supply SELV series Features : Universal AC input I Full range (up to 305VAC) Built-in active PFC function High efficiency up to 94% Protections: Short circuit

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H765A, H766A, H766A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS INSTALLATI INSTRUCTIS APPLICATI The H765A, H766A, H765A and H766A Wall-Mount Humidity/Temperature Sensors are universal

More information

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual SeriesTWO RGB Fluorescent Fixtures Installation and Instruction Manual Brightline LP 580 Mayer Street #7, Bridgeville PA 15017 Phone 1-412-206-0106 Fax 1-412-206-0146 www.brightlines.com The Brightline

More information

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator Service Outlet Quick Start Steps Keyed latch Cover 115VAC, 15A Plastic base Operator Unpack the Operator Site Planning and Operator Installation The illustrations and instructions presented in this guide

More information

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT -12 A 120W Single Output Switching Power Supply series Features : Universal AC input I Full range (up to 305VAC) Built-in active PFC function High efficiency up to 93.5% Protections: Short circuit I Over

More information

Model RFT9709 Transmitter Instruction Manual

Model RFT9709 Transmitter Instruction Manual Model RFT9709 Transmitter Instruction Manual March 1999 Model RFT9709 Transmitter Instruction Manual For technical assistance, phone the Micro Motion Customer Service Department: In the U.S.A., phone

More information

Features : IP65 IP67 SELV

Features : IP65 IP67 SELV ID 2000000000 320W Single Output Switching Power Supply SELV HLG-320H series Features : Universal AC input I Full range (up to 305VAC) Built-in active PFC function High efficiency up to 95% Protections:

More information

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy SAM Listed Model: LD12W - LD200W Series Environmental Strip Lighting Drive Mode: Constant Voltage Technology: PFC Off-Line Switch Mode Output Power: 12-200W Max. Output Voltages: 12VDC or 24VDC Optional

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation...

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Reflections Housing with EldoLED and Lutron Hi-lume Drivers EDIHE_ 1.4

Reflections Housing with EldoLED and Lutron Hi-lume Drivers EDIHE_ 1.4 Installation Instructions for 90EDIHE Reflections Housing with EldoLED and Lutron Hi-lume Drivers EDIHE_.4 LED GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product

More information

Microprocessor Control Board Set Up Procedures (OR PLC)

Microprocessor Control Board Set Up Procedures (OR PLC) Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board

More information

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing) X20092 DMFC36 Issue: 2 User manual Date: 31/10/14 Page: 1 of 10 KEY FEATURES Standard DIN Rail Mounting Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H7635A, H766A, H7636A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATI The H765A, H766A, H7635A and H7636A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity

More information

Trailing-edge Dimmer ADT400

Trailing-edge Dimmer ADT400 -3-0416. TRAIIG-EDGE DIMMER. PAGE 1 OF 5 0-10V controlled trailing-edge dimmer housed in a DI-rail enclosure 10W to 400W Contents Technical specification and installation 2 Related product options 3 Wiring

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Electro Controls. Input-Output Modules WattsIndustries.co.uk Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

TOA PROFESSIONAL POWER AMP

TOA PROFESSIONAL POWER AMP Operating Instruction Manual TOA PROFESSIONAL POWER AMP Model P-150M, P-300M TOA ELECTRIC CO, LTD. KOBE, JAPAN Contents Precautions... 2 General Description... 2 Features... 3 Specifications... 4~5 Performance

More information

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS INSTALATION, OPERATION & MAINTENANCE MANUAL FOR PA-1001A Series SIGNAL CONDITIONER & CONVERTORS PA1001A 7/02 Page 1 of 11 SIGNAL CONDITIONER & CONVERTERS PA1001A Series INTRODUCTION: The PA1001A series

More information

OTi DALI 80/ / CH OTi DALI 50/ / CH

OTi DALI 80/ / CH OTi DALI 50/ / CH www.osram.com OTi DALI 80/220-240/24 1-4 CH OTi DALI 50/220-240/24 1-4 CH 24 V DALI Constant Voltage LED driver Dimmable range 0% - 100% Benefits Slim form factor for mounting on the cove or in linear

More information

AC Voltage-Current Interface Unit (VCIU) for the Galaxy Millennium Controller With L10 L14, L20 L24, L30 L38, L40 L44, and L57 Interface Units

AC Voltage-Current Interface Unit (VCIU) for the Galaxy Millennium Controller With L10 L14, L20 L24, L30 L38, L40 L44, and L57 Interface Units AC Voltage-Current Interface Unit (VCIU) for the Galaxy Millennium Controller With L10 L14, L20 L24, L30 L38, L40 L44, and L57 Interface Units Operation, Installation and Maintenance Manual Select Code

More information

www.greenelectricalsupply.com Installation Guide Model: WLVD Wireless Low Voltage Dimmer (Receiver) Specifications: Power Supply 24 V DC Place on 24V power line prior to light load. 10A Maximum Load Package

More information

OSMAC RDR Low-voltage Retrofit Kit

OSMAC RDR Low-voltage Retrofit Kit OSMAC RDR Low-voltage Retrofit Kit Part Number RDR0160LVN0 User s Guide Installation of the RDR (Radio Data Receiver) low-voltage unit will enable you to remotely operate your existing Vari-Time 4000 satellite

More information

Round or Square Chicago Plenum Down Light Housing with Lamp

Round or Square Chicago Plenum Down Light Housing with Lamp Installation Instructions for 90ELED-DCP Round or Square Chicago Plenum Down Light Housing with Lamp LED E_-L_DC. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations.

More information

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in

More information

FEATURES DESCRIPTION THE OEM ADVANTAGE

FEATURES DESCRIPTION THE OEM ADVANTAGE FEATURES PMAC2 controller from Delta-Tau controls amp bridge directly MODEL POWER I-CONT (A) I-PEAK (A) 7229AC 32~132VAC 10 20 7429AC 32~264VAC 10 20 Serial digital current feedback from U & V phases Mini

More information

LED control gear Compact fixed output. Uconverter LCI 50 W 1050 ma N020 TOP series Ø4,5. Ordering data

LED control gear Compact fixed output. Uconverter LCI 50 W 1050 ma N020 TOP series Ø4,5. Ordering data Product description 1-channel ED control gear Independent ED control gear for indoor use Output current and output voltage adjustable output input channel ominal life of 50,000 h (at ta max. with a failure

More information

Fixture Built-in Sensor Daylight Harvest Version

Fixture Built-in Sensor Daylight Harvest Version Fixture Built-in Sensor Daylight Harvest Version Model: HC419VRC /DH Infrared remote receiver Detection area Hold-time Daylight sensor Buzzer Sensor antenna Photocell Installation hole (4.2mm) 4.2 45 Stand-by

More information

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21) IOM Model 1050 Strain Gage Transmitter Installation & Operation Manual (Cage Code #1MU21) Model 1050 Strain Gage Transmitter Installation & Operation Manual CONTENTS I. GENERAL...1 II. INSTALLATION...2

More information

Connection and Operation (Built-In Controller Package)

Connection and Operation (Built-In Controller Package) (Built-In Controller Package) Names and Functions of Parts Power Supply Input Terminal (CN1) Regeneration Unit Thermal Input Terminal (CN1) Electromagnetic Brake Terminal (CN1) Motor Connector (CN2) CHARGE

More information

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards A. Primary Technical Data: Transmitter Operating voltage DC 24V Operating current. < 450mA

More information

LED Smart Inc. LED PRODUCTS CATALOGUE. SPRING 2012 CATALOGUE

LED Smart Inc. LED PRODUCTS CATALOGUE.  SPRING 2012 CATALOGUE Inc. LED PRODUCTS CATALOGUE SPRING 2012 CATALOGUE Inc. works to continually improve our products, we reserve the right to change or modify the designs or specifications of products in this catalogue at

More information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant

More information

MODEL KBWD-15 Pulse Width Modulated (PWM)

MODEL KBWD-15 Pulse Width Modulated (PWM) MODEL KBWD-15 Pulse Width Modulated (PWM) DC MOTOR SPEED CONTROL WHISPER DRIVE INSTALLATION AND OPERATING INSTRUCTIONS See Safety Warning on Page 1 and Application Note Warning on Page 2 The information

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control Installation Guide MMTM/PB Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control Programmable between 1 minute and 30 minutes, in 1 minute steps Suitable

More information

ETC Installation Guide

ETC Installation Guide Unison Echo Light Sensor Overview The provides light level measurement and lighting control for the connected Echo control system. The sensor measures lighting conditions to maintain a programmed lighting

More information

Atkinson Dynamics Intercom Model AD-28X-MV Installation and Service Instructions

Atkinson Dynamics Intercom Model AD-28X-MV Installation and Service Instructions Atkinson Dynamics Intercom Model AD-8X-MV Installation and Service Instructions 9 REV. B 0 Printed in U.S.A. INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL AD-8X-MV SAFETY MESSAGE TO INSTALLERS, USERS

More information

CHAPTER 3 WIRING DANGER

CHAPTER 3 WIRING DANGER CHAPTER WIRING DANGER Hazardous Voltage Before accessing the AC drive: Disconnect all power to the AC drive. Wait five minutes for DC bus capacitors discharge. Any electrical or mechanical modification

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

dmx2pwm 9 channel dimmer setup manual

dmx2pwm 9 channel dimmer setup manual dmx2pwm 9 channel dimmer setup manual www.ecue.de dmx2pwm 9ch dimmer - setup manual e:cue control GmbH An OSRAM Company Rev. 1.2_06/2009 dmx2pwm 9ch dimmer - setup manual table of contents 1. Device Overview....................................

More information

Contents. Warranty and Disclaimer 2

Contents. Warranty and Disclaimer 2 Contents Warranty and Disclaimer 2 Physical Dimensions Board Layout 3 Usage Using the PWM board 4 Setting the start address 4 Dimming LED s 5,6 Typical hookup 7 Terminator 8 Troubleshooting Ground, termination,

More information

UNIVERSAL LOW VOLTAGE LED DIMMERS DMS-P SERIES

UNIVERSAL LOW VOLTAGE LED DIMMERS DMS-P SERIES UNIVERSAL LOW VOLTAGE LED DIMMERS Description DMS-P series universal PWM dimmers are designed for smooth, flicker-free dimming of all constant voltage LED modules, including MR16 bulbs as well as 12V/24V

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

Spa Control Troubleshooting Guide

Spa Control Troubleshooting Guide Spa Control Troubleshooting Guide Model: RS, Voltage: 0V Major System Components TOPSIDE PANEL SYSTEM PACK FAULT CIRCUIT INTERRUPTER (GFCI) GFCI models vary in size and style. Your GFCI may look different.

More information